1
|
Hefnawy M, El-Gendy M, Al-Salem H, Marenga H, El-Azab A, Abdel-Aziz A, Gamal AE, Alanazi M, Obaidullah A, Al-Hossaini A, Hefnawy A. Trends in monoliths: Packings, stationary phases and nanoparticles. J Chromatogr A 2023; 1691:463819. [PMID: 36724721 DOI: 10.1016/j.chroma.2023.463819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/18/2023] [Accepted: 01/20/2023] [Indexed: 01/26/2023]
Abstract
Monoliths media are gaining interest as excellent substitutes to conventional particle-packed columns. Monolithic columns show higher permeability and lower flow resistance than conventional liquid chromatography columns, providing high-throughput performance, resolution and separation in short run times. Monolithic columns with longer length, smaller inner diameter and specific selectivity to peptides or enantiomers have been played important role in hyphenated system. Monolithic stationary phases possess great efficiency, resolution, selectivity and sensitivity in the separation of complex biological samples, such as the complex mixtures of peptides for proteome analysis. The development of monolithic stationary phases has opened the new avenue in chromatographic separation science and is in turn playing much more important roles in the wide application area. Monolithic stationary phases have been widely used in fast and high efficiency one- and multi-dimensional separation systems, miniaturized devices, and hyphenated system coupled with mass spectrometers. The developing technology for preparation of monolithic stationary phases is revolutionizing the column technology for the separation of complex biological samples. These techniques using porous monoliths offer several advantages, including miniaturization and on-line coupling with analytical instruments. Additionally, monoliths are ideal support media for imprinting template-specific sites, resulting in the so-called molecularly-imprinted monoliths, with ultra-high selectivity. In this review, the origin of the concept, the differences between their characteristics and those of traditional packings, their advantages and drawbacks, theory of separations, the methods for the monoliths preparation of different forms, nanoparticle monoliths and metal-organic framework are discussed. Two application areas of monolithic metal-organic framework and nanoparticle monoliths are provided. The review article discusses the results reported in a total of 218 references. Other older references were included to illustrate the historical development of monoliths, both in preparation and types, as well as separation mechanism.
Collapse
Affiliation(s)
- Mohamed Hefnawy
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia; Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt.
| | - Manal El-Gendy
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Huda Al-Salem
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Hanin Marenga
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Adel El-Azab
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Alaa Abdel-Aziz
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Ali El Gamal
- Department of Pharmacognosy and Medicinal, Aromatic & Poisonous Plant Research Center (MAPPRC), College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Mohammed Alanazi
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Ahmad Obaidullah
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Abdullah Al-Hossaini
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Abdullah Hefnawy
- Faculty of Medicine, Mansoura Manchester Medical Program, Mansoura University, Mansoura, Egypt
| |
Collapse
|
2
|
Neequaye T, El Rassi Z. Poly(carboxyethyl acrylate-co-ethylene glycol dimethacrylate) precursor monolith with bonded anthracenyl ligands for use in reversed-phase capillary electrochromatography based on hydrophobic and π-π interactions. J Chromatogr A 2022; 1682:463526. [PMID: 36166884 DOI: 10.1016/j.chroma.2022.463526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 09/17/2022] [Accepted: 09/19/2022] [Indexed: 11/18/2022]
Abstract
In this research report, the post polymerization functionalization (PPF) of a carboxyethyl acrylate (CEA)-co-ethylene glycol dimethacrylate (EDMA) [poly-CEA-co-EDMA)] precursor monolith with 2-aminoanthracene was carried out in the presence of an organic solvent soluble carbodiimide, namely N,N´-dicyclohexylcarbodiimide (DCC), yielding the so-called anthracenyl-poly-CEA-co-EDMA monolith. This novel monolith proved to be an excellent monolithic stationary for reversed-phase capillary electrochromatography (RP-CEC) with hydrophobic and π-π interactions of a wide range of nonpolar solutes including those bearing aryl functional groups in their structures such as polycyclic aromatic hydrocarbons (PAHs), toluene derivatives and aniline derivatives as well as solutes carrying in their structures electron withdrawing substituents such as dinitrophenyl-amino acids (DNP-AAs) and di-DNP-AAs. The retention behaviors of the just mentioned solutes obtained on the anthracenyl-poly-CEA-co-EDMA monolithic column were compared to those obtained on octadecyl-poly-CEA-co-EDMA monolithic column prepared from the same carboxy-precursor monolith. The results demonstrated the superiority of anthracenyl column over the octadecyl column for the separation and enhanced selectivity for aromatic solutes since it provides not only hydrophobic interactions but also π-π interactions with aromatic nonpolar solutes.
Collapse
Affiliation(s)
- Theophilus Neequaye
- Department of Chemistry, Oklahoma State University, Stillwater, OK 74078, USA
| | - Ziad El Rassi
- Department of Chemistry, Oklahoma State University, Stillwater, OK 74078, USA.
| |
Collapse
|
3
|
Česla P, Hájek T, Urban J, Holčapek M. Liquid chromatography at the university of pardubice: a tribute to Professor Pavel Jandera. J Sep Sci 2022; 45:3214-3231. [PMID: 35932491 DOI: 10.1002/jssc.202200618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/03/2022] [Accepted: 08/03/2022] [Indexed: 11/12/2022]
Abstract
Pavel Jandera was a world-leading analytical chemist who devoted his entire professional life to research in the field of high-performance liquid chromatography. During all his scientific career, he worked at the Department of Analytical Chemistry at the University of Pardubice, Czech Republic. His greatest contribution to the field of liquid chromatography was the introduction of a comprehensive theory of liquid chromatography with programmed elution conditions. He was also involved in the research of gradient elution techniques in preparative chromatography, modeling of retention and selectivity in various phase systems, preparation of organic monolithic microcolumns and, last but not least, in the development of theory and practical applications of two-dimensional liquid chromatography, mainly in the comprehensive form. In this review article, we have tried to capture the highlights of his scientific career and provide the readers with a detailed overview of Pavel Jandera's contribution to the evolution of separation sciences. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Petr Česla
- Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czech Republic
| | - Tomáš Hájek
- Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czech Republic
| | - Jiří Urban
- Faculty of Science, Department of Chemistry, Masaryk University, Kamenice 5, Brno, CZ-62500, Czech Republic
| | - Michal Holčapek
- Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, Pardubice, CZ-53210, Czech Republic
| |
Collapse
|
4
|
Mansour FR, Waheed S, Paull B, Maya F. Porogens and porogen selection in the preparation of porous polymer monoliths. J Sep Sci 2019; 43:56-69. [DOI: 10.1002/jssc.201900876] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 09/26/2019] [Accepted: 09/29/2019] [Indexed: 01/10/2023]
Affiliation(s)
- Fotouh R. Mansour
- Department of Pharmaceutical Analytical ChemistryFaculty of PharmacyTanta University Tanta Egypt
- Pharmaceutical Services CenterFaculty of PharmacyTanta University Tanta Egypt
| | - Sidra Waheed
- Australian Centre for Research on Separation Science (ACROSS)School of Natural Sciences, ChemistryUniversity of Tasmania Hobart Australia
- ARC Centre of Excellence for Electromaterials Science (ACES) School of Natural Sciences, ChemistryUniversity of Tasmania Hobart Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS)School of Natural Sciences, ChemistryUniversity of Tasmania Hobart Australia
- ARC Centre of Excellence for Electromaterials Science (ACES) School of Natural Sciences, ChemistryUniversity of Tasmania Hobart Australia
| | - Fernando Maya
- Australian Centre for Research on Separation Science (ACROSS)School of Natural Sciences, ChemistryUniversity of Tasmania Hobart Australia
| |
Collapse
|
5
|
Multichannel separation device with parallel electrochemical detection. J Chromatogr A 2019; 1610:460537. [PMID: 31537305 DOI: 10.1016/j.chroma.2019.460537] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/22/2019] [Accepted: 09/08/2019] [Indexed: 11/23/2022]
Abstract
A device with four parallel channels was designed and manufactured by 3D printing in titanium. A simple experimental setup allowed splitting of the mobile phase in four parallel streams, such that a single sample could be analysed four times simultaneously. The four capillary channels were filled with a monolithic stationary phase, prepared using a zwitterionic functional monomer in combination with various dimethacrylate cross-linkers. The resulting stationary phases were applicable in both reversed-phase and hydrophilic-interaction retention mechanisms. The mobile-phase composition was optimized by means of a window diagram so as to obtain the highest possible resolution of dopamine precursors and metabolites on all columns. Miniaturized electrochemical detectors with carbon fibres as working electrodes and silver micro-wires as reference electrodes were integrated in the device at the end of each column. Experimental separations were successfully compared with those predicted by a three-parameter retention model. Finally, dopamine was determined in human urine to further confirm applicability of the developed device.
Collapse
|
6
|
Capillary methacrylate-based monoliths by grafting from/to γ-ray polymerization on a tentacle-type reactive surface for the liquid chromatographic separations of small molecules and intact proteins. J Chromatogr A 2017; 1498:46-55. [DOI: 10.1016/j.chroma.2016.11.039] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 10/20/2016] [Accepted: 11/21/2016] [Indexed: 12/13/2022]
|
7
|
Porous monoliths for on-line sample preparation: A review. Anal Chim Acta 2017; 964:24-44. [DOI: 10.1016/j.aca.2017.02.002] [Citation(s) in RCA: 115] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 01/30/2017] [Accepted: 02/01/2017] [Indexed: 11/23/2022]
|
8
|
Jonnada M, Rathnasekara R, El Rassi Z. Recent advances in nonpolar and polar organic monoliths for HPLC and CEC. Electrophoresis 2014; 36:76-100. [PMID: 25266173 DOI: 10.1002/elps.201400426] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2014] [Revised: 09/20/2014] [Accepted: 09/22/2014] [Indexed: 01/17/2023]
Abstract
This article is aimed at providing a review of the progress made in the field over the period 2011 to present in order to expand in parts on two previous reviews (S. Karenga and Z. El Rassi, Electrophoresis, 2011, 32, 90-104; D. Gunasena and Z. El Rassi, Electrophoresis, 2012, 33, 251-261). In brief, this review article describes progress made in nonpolar and polar monoliths used in RP HPLC and CEC and in hydrophilic interaction LC/CEC, respectively. This article is by no means an exhaustive review of the literature; it is rather a survey of the recent progress made in the field with 69 references published on nonpolar and polar polymeric monoliths.
Collapse
Affiliation(s)
- Murthy Jonnada
- Department of Chemistry, Oklahoma State University, Stillwater, OK, USA
| | | | | |
Collapse
|
9
|
Ding L, Guo Z, Xiao Y, Xue X, Zhang X, Liang X. Evaluation and comparison ofn-alkyl chain and polar ligand bonded stationary phases for protein separation in reversed-phase liquid chromatography. J Sep Sci 2014; 37:2467-73. [DOI: 10.1002/jssc.201400238] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Revised: 05/21/2014] [Accepted: 06/21/2014] [Indexed: 11/06/2022]
Affiliation(s)
- Ling Ding
- Key Laboratory of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics, Chinese Academy of Sciences; Dalian China
| | - Zhimou Guo
- Key Laboratory of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics, Chinese Academy of Sciences; Dalian China
| | - Yuansheng Xiao
- Key Laboratory of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics, Chinese Academy of Sciences; Dalian China
| | - Xingya Xue
- Key Laboratory of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics, Chinese Academy of Sciences; Dalian China
| | - Xiuli Zhang
- Key Laboratory of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics, Chinese Academy of Sciences; Dalian China
| | - Xinmiao Liang
- Key Laboratory of Separation Science for Analytical Chemistry; Dalian Institute of Chemical Physics, Chinese Academy of Sciences; Dalian China
| |
Collapse
|
10
|
Jandera P. Advances in the development of organic polymer monolithic columns and their applications in food analysis—A review. J Chromatogr A 2013; 1313:37-53. [DOI: 10.1016/j.chroma.2013.08.010] [Citation(s) in RCA: 98] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Revised: 07/29/2013] [Accepted: 08/03/2013] [Indexed: 01/04/2023]
|
11
|
Staňková M, Jandera P, Škeříková V, Urban J. Cross-linker effects on the separation efficiency on (poly)methacrylate capillary monolithic columns. Part II. Aqueous normal-phase liquid chromatography. J Chromatogr A 2013; 1289:47-57. [DOI: 10.1016/j.chroma.2013.03.025] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Revised: 03/05/2013] [Accepted: 03/07/2013] [Indexed: 01/03/2023]
|
12
|
Metal organic framework–organic polymer monolith stationary phases for capillary electrochromatography and nano-liquid chromatography. Anal Chim Acta 2013; 779:96-103. [DOI: 10.1016/j.aca.2013.03.071] [Citation(s) in RCA: 111] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 03/25/2013] [Accepted: 03/29/2013] [Indexed: 11/18/2022]
|
13
|
Jandera P, Staňková M, Škeříková V, Urban J. Cross-linker effects on the separation efficiency on (poly)methacrylate capillary monolithic columns. Part I. Reversed-phase liquid chromatography. J Chromatogr A 2012; 1274:97-106. [PMID: 23273635 DOI: 10.1016/j.chroma.2012.12.003] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Revised: 11/29/2012] [Accepted: 12/03/2012] [Indexed: 01/07/2023]
Abstract
We synthesized 8 polymethacrylate monolithic capillary columns using laurylmethacrylate functional monomer and various cross-linking monomers differing in the polarity and size. The efficiency of monolithic columns for low-molecular compounds significantly improved with increasing number of repeat non-polar methylene groups in the cross-linker molecules, correlating with greater proportion of small pores with size less than 50 nm. The best efficiency with HETP=25 μm for alkylbenzenes was achieved for columns prepared using hexamethylene dimethacrylate (HEDMA). Columns prepared with polar (poly)oxyethylene dimethacrylate cross-linkers show also improved efficiency with increasing chain length and generally better performance in comparison to the (poly)methylene dimethacrylate cross-linkers of comparable size, however with less apparent effects of the chain lengths on the pore distribution. The monolithic columns prepared with tetraoxyethylene dimethacrylate (TeEDMA) showed the best efficiency of all the columns tested, corresponding to HETP=15 μm (approx. 70,000 theoretical plates/m), show excellent column-to-column reproducibility with standard deviations of 2.5% in retention times, good permeability and low mass transfer resistance, so that is suitable for fast separation of low-molecular compounds in 2 min or less. By modification of the fused-silica capillary inner walls pre-treatment procedure, very good long-term stability was achieved even in 0.5 mm i.d. capillary format. The TeEDMA column can be also used for size-exclusion chromatography of lower non-polar synthetic polymers, whereas it is less suitable for separations of proteins than the HEDMA column.
Collapse
Affiliation(s)
- Pavel Jandera
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic.
| | | | | | | |
Collapse
|
14
|
Rigobello-Masini M, Penteado JCP, Masini JC. Monolithic columns in plant proteomics and metabolomics. Anal Bioanal Chem 2012; 405:2107-22. [DOI: 10.1007/s00216-012-6574-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2012] [Revised: 11/02/2012] [Accepted: 11/13/2012] [Indexed: 12/16/2022]
|
15
|
Singco B, Lin CL, Cheng YJ, Shih YH, Huang HY. Ionic liquids as porogens in the microwave-assisted synthesis of methacrylate monoliths for chromatographic application. Anal Chim Acta 2012; 746:123-33. [DOI: 10.1016/j.aca.2012.08.034] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2012] [Revised: 08/15/2012] [Accepted: 08/19/2012] [Indexed: 11/24/2022]
|
16
|
Urban J, Jandera P. Recent advances in the design of organic polymer monoliths for reversed-phase and hydrophilic interaction chromatography separations of small molecules. Anal Bioanal Chem 2012; 405:2123-31. [PMID: 22995998 DOI: 10.1007/s00216-012-6392-x] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2012] [Revised: 08/24/2012] [Accepted: 08/27/2012] [Indexed: 10/27/2022]
Abstract
Owing to their favorable porous structure with pore size distribution shifted towards large flow-through pores, organic polymer monoliths have been mainly employed for the separation of macromolecules in gradient elution liquid chromatography. The absence of significant amounts of small pores with a stagnant mobile phase and the resulting low surface area were considered as the main reason for their poor behavior in the isocratic separation of small molecules. Several recent efforts have improved the separation power of organic polymer monoliths for small molecules offering column efficiency up to tens of thousands of plates per meter. These attempts include optimization of the composition of polymerization mixture, including the variation of functional monomer, the cross-linking monomer, and the porogen solvents mixture, adjustment of polymerization temperature, and time. Additionally, post-polymerization modifications including hypercross-linking and the use of carbon nanostructures showed significant improvement in the column properties. This review describes recent developments in the preparation of organic polymer monoliths suitable for the separation of small molecules in the isocratic mode as well as the main factors affecting the column efficiency.
Collapse
Affiliation(s)
- Jiri Urban
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic
| | | |
Collapse
|
17
|
Wang N, He S, Zhu Y. Low-level bromate analysis by ion chromatography on a polymethacrylate-based monolithic column followed by a post-column reaction. Eur Food Res Technol 2012. [DOI: 10.1007/s00217-012-1800-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
18
|
Retention times and bandwidths in reversed-phase gradient liquid chromatography of peptides and proteins. J Chromatogr A 2011; 1218:8874-89. [DOI: 10.1016/j.chroma.2011.06.064] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Revised: 05/16/2011] [Accepted: 06/14/2011] [Indexed: 11/20/2022]
|