1
|
Fernandes MA, Hanck-Silva G, Baveloni FG, Oshiro Junior JA, de Lima FT, Eloy JO, Chorilli M. A Review of Properties, Delivery Systems and Analytical Methods for the Characterization of Monomeric Glycoprotein Transferrin. Crit Rev Anal Chem 2020; 51:399-410. [DOI: 10.1080/10408347.2020.1743639] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Mariza Aires Fernandes
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
| | - Gilmar Hanck-Silva
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
| | - Franciele Garcia Baveloni
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
| | | | - Felipe Tita de Lima
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
| | - Josimar O. Eloy
- College of Pharmacy, Dentistry and Nursing, Federal University of Ceara (UFC), Fortaleza, Ceará, Brazil
| | - Marlus Chorilli
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
| |
Collapse
|
2
|
Caslavska J, Schild C, Thormann W. High-resolution capillary zone electrophoresis and mass spectrometry for distinction of undersialylated and hypoglycosylated transferrin glycoforms in body fluids. J Sep Sci 2019; 43:241-257. [PMID: 31605446 DOI: 10.1002/jssc.201900857] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Revised: 10/01/2019] [Accepted: 10/09/2019] [Indexed: 12/21/2022]
Abstract
High-resolution capillary zone electrophoresis is used to distinguish transferrin glycoforms present in human serum, cerebrospinal fluid, and serum treated with neuraminidase and N-glycosidase F. The obtained data are compared to mass spectrometry data from the literature. The main focus is on the analysis of the various asialo-transferrin, monosialo-transferrin, and disialo-transferrin molecules found in these samples. The features of capillary zone electrophoresis and mass spectrometry are reviewed and highlighted in the context of the analysis of undersialylated and hypoglycosylated transferrin molecules. High-resolution capillary zone electrophoresis represents an effective tool to assess the diversity of transferrin patterns whereas mass spectrometry is the method of choice to elucidate structural identification about the glycoforms. Hypoglycosylated transferrin glycoforms present in sera of alcohol abusers and normal subjects are structurally identical to those in sera of patients with a congenital disorder of glycosylation type I. Asialo-transferrin, monosialo-transferrin and disialo-transferrin observed in sera of patients with a type II congenital disorder of glycosylation or a hemolytic uremic syndrome, in cerebrospinal fluid and after treatment of serum with neuraminidase are undersialylated transferrin glycoforms with two N-glycans of varying structure. Undersialylated disialo-transferrin is also observed in sera with high levels of trisialo-transferrin.
Collapse
Affiliation(s)
- Jitka Caslavska
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Christof Schild
- Institute of Clinical Chemistry, Inselspital, University Hospital and University of Bern, Bern, Switzerland
| | - Wolfgang Thormann
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| |
Collapse
|
3
|
Yoo G, Kim J, Yoon KJ, Lee JH. The characteristics of transferrin variants by carbohydrate-deficient transferrin tests using capillary zone electrophoresis. J Clin Lab Anal 2018; 32:e22451. [DOI: 10.1002/jcla.22451] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Accepted: 03/23/2018] [Indexed: 11/08/2022] Open
Affiliation(s)
- Gilsung Yoo
- Departments of Laboratory Medicine; Yonsei University Wonju College of Medicine; Wonju Korea
| | - Juwon Kim
- Departments of Laboratory Medicine; Yonsei University Wonju College of Medicine; Wonju Korea
| | - Kap Joon Yoon
- Departments of Laboratory Medicine; Yonsei University Wonju College of Medicine; Wonju Korea
| | - Jong-Han Lee
- Departments of Laboratory Medicine; Yonsei University Wonju College of Medicine; Wonju Korea
| |
Collapse
|
4
|
Tobler M, Caslavska J, Burda P, Thormann W. High-resolution capillary zone electrophoresis for transferrin glycoform analysis associated with congenital disorders of glycosylation. J Sep Sci 2018; 41:2808-2818. [PMID: 29701302 DOI: 10.1002/jssc.201800082] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 04/18/2018] [Accepted: 04/19/2018] [Indexed: 11/10/2022]
Abstract
High-resolution capillary zone electrophoresis is used to assess the transferrin profile in serum of patients with eight different congenital disorders of glycosylation that represent type I, type II, and mixed type I/II disorders. Capillary zone electrophoresis data are compared to patterns obtained by gel isoelectric focusing. The high-resolution capillary zone electrophoresis method is shown to represent an effective tool to assess the diversity of transferrin patterns. Hypoglycosylated disialo-, monosialo-, and asialo-transferrin in type I cases can be distinguished from the corresponding underdesialylated transferrin glycoforms present in type II disorders. The latter can be separated from and detected ahead of their corresponding hypoglycosylated forms of type I patients. Both types of glycoforms are detected in sera of mixed type I/II patients. The assay has the potential to be used as screening method for congenital disorders of glycosylation. It can be run with a few microliters of serum when microvials are used.
Collapse
Affiliation(s)
- Micha Tobler
- Division of Metabolism, University Children's Hospital Zürich, Zürich, Switzerland
| | - Jitka Caslavska
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Patricie Burda
- Division of Metabolism, University Children's Hospital Zürich, Zürich, Switzerland
| | - Wolfgang Thormann
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| |
Collapse
|
5
|
Caslavska J, Thormann W. Monitoring of transferrin isoforms in biological samples by capillary electrophoresis. J Sep Sci 2017; 41:303-322. [PMID: 28885776 DOI: 10.1002/jssc.201700914] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 09/04/2017] [Accepted: 09/04/2017] [Indexed: 11/10/2022]
Abstract
Work dealing with the monitoring of transferrin isoforms in human serum and other body fluids by capillary electrophoresis is reviewed. It comprises capillary zone electrophoresis and capillary isoelectric focusing efforts that led to the exploration and use of assays for the determination of carbohydrate-deficient transferrin as a marker for excessive alcohol intake, genetic variants of transferrin, congenital disorders of glycosylation and β-2-transferrin, which is a marker for cerebrospinal fluid leakage. This paper provides insight into the development, specifications, strengths, weaknesses, and routine use of the currently known capillary electrophoresis based assays suitable to detect transferrin isoforms in body fluids. The achievements reached so far indicate that capillary zone electrophoresis is an attractive technology to monitor the molecular forms of transferrin in biological specimens as the assays do not require an elaborate sample pretreatment and thus can be fully automated for high-throughput analyses on multicapillary instruments. Assays based on capillary isoelectric focusing are less attractive. They require immunoextraction of transferrin from the biological matrix and mobilization after focusing if instrumentation with a whole-column imaging detector is not available. Interactions of the carrier ampholytes with the iron of transferrin may prevent iron saturation and thus provide more complicated isoform patterns.
Collapse
Affiliation(s)
- Jitka Caslavska
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Wolfgang Thormann
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| |
Collapse
|
6
|
Bortolotti F, Sorio D, Bertaso A, Tagliaro F. Analytical and diagnostic aspects of carbohydrate deficient transferrin (CDT): A critical review over years 2007-2017. J Pharm Biomed Anal 2017; 147:2-12. [PMID: 28912047 DOI: 10.1016/j.jpba.2017.09.006] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2017] [Revised: 08/30/2017] [Accepted: 09/01/2017] [Indexed: 02/07/2023]
Abstract
The need for investigating alcohol abuse by means of objective tools is worldwide accepted. Among the currently available biomarkers of chronic alcohol abuse, carbohydrate-deficient transferrin (CDT) is one of the most used indicator, mainly because of its high specificity. However, some CDT analytical and interpretation aspects are still under discussion, as witnessed by numerous research papers and reviews. The present article presents a critical review of the literature on CDT appeared in the period from 2007 to 2017 (included). The article is organized in the following sections: (1) introduction, (2) pre-analytical aspects (3) analytical aspects (4) diagnostic aspects (5) concluding remarks. As many as 139 papers appeared in the international literature and retrieved by the search engines PubMed, Web of Science and Scopus are quoted.
Collapse
Affiliation(s)
- F Bortolotti
- Dept of Diagnostics and Public Health, Unit of Forensic Medicine, University of Verona, Italy.
| | - D Sorio
- Dept of Diagnostics and Public Health, Unit of Forensic Medicine, University of Verona, Italy
| | - A Bertaso
- Dept of Diagnostics and Public Health, Unit of Forensic Medicine, University of Verona, Italy
| | - F Tagliaro
- Dept of Diagnostics and Public Health, Unit of Forensic Medicine, University of Verona, Italy; Institute of Pharmacy and Translational Medicine, Sechenov First Medical University, Moskow, Russia
| |
Collapse
|
7
|
Caslavska J, Lanz C, Burda P, Tobler M, Thormann W. Analysis of genetic variants of transferrin in human serum after desialylation by capillary zone electrophoresis and capillary isoelectric focusing. J Sep Sci 2017; 40:2488-2497. [PMID: 28371325 DOI: 10.1002/jssc.201700211] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Revised: 03/21/2017] [Accepted: 03/21/2017] [Indexed: 12/31/2022]
Abstract
Capillary electrophoresis analysis of transferrin in human serum is used to assess genetic variants after desialylation with neuraminidase and iron saturation to reduce the complexity of the transferrin pattern and thus facilitate the recognition of transferrin polymorphisms. Asialo-transferrin forms are analyzed by capillary zone electrophoresis using assay conditions as for the monitoring of carbohydrate-deficient transferrin or by capillary isoelectric focusing in a pH 5-8 gradient which requires immunoextraction of transferrin prior to analysis. With the carrier ampholytes used, peaks for iron saturated and iron depleted transferrin are monitored which indicates complexation of iron ions by carrier ampholytes. For BC, CD, and BD genetic variants, the expected peaks for B, C, and D forms of transferrin were detected with both methods. Monitoring of CC patterns revealed three cases, namely those producing double peaks in both methods, a double peak in capillary isoelectric focusing only and a double peak in capillary zone electrophoresis only. For all samples analyzed, data obtained by capillary isoelectric focusing could be confirmed with gel isoelectric focusing. The two capillary electrophoresis methods are shown to represent effective tools to assess unusual transferrin patterns, including genetic variants with dissimilar abundances of the two forms.
Collapse
Affiliation(s)
- Jitka Caslavska
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Christian Lanz
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | - Patricie Burda
- Division of Metabolism, University Children's Hospital Zürich, Zürich, Switzerland
| | - Micha Tobler
- Division of Metabolism, University Children's Hospital Zürich, Zürich, Switzerland
| | - Wolfgang Thormann
- Clinical Pharmacology Laboratory, Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| |
Collapse
|
8
|
IFCC approved HPLC reference measurement procedure for the alcohol consumption biomarker carbohydrate-deficient transferrin (CDT): Its validation and use. Clin Chim Acta 2017; 465:91-100. [DOI: 10.1016/j.cca.2016.12.022] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Accepted: 12/21/2016] [Indexed: 11/21/2022]
|
9
|
Kašička V. Outlook--Analysis of amino acids, peptides, and proteins: a virtual special issue. J Sep Sci 2016; 38:vii-viii. [PMID: 25885353 DOI: 10.1002/jssc.201570075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|