1
|
Preparation of polar embedded C18 stationary phase for efficient separation of peptides and proteins in high performance liquid chromatography. J Chromatogr A 2022; 1684:463534. [DOI: 10.1016/j.chroma.2022.463534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 08/28/2022] [Accepted: 09/26/2022] [Indexed: 11/24/2022]
|
2
|
Ali A, Alharthi S, Al-Shaalan NH, Santali EY. Development of Narrow-Bore C18 Column for Fast Separation of Peptides and Proteins in High-Performance Liquid Chromatography. Polymers (Basel) 2022; 14:polym14132576. [PMID: 35808622 PMCID: PMC9268927 DOI: 10.3390/polym14132576] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 06/19/2022] [Accepted: 06/23/2022] [Indexed: 11/27/2022] Open
Abstract
Separation with high efficiency and good resolution is constantly in demand in the pharmaceutical industry. The fast and efficient separation of complex samples such as peptides and proteins is a challenging task. To achieve high efficiency with good resolution, chromatographers are moving towards small particles packed into narrow-bore columns. Silica monolith particles (sub-2 µm) were derivatized with chlorodimethyl octadecyl silane (C18) and packed into stainless steel columns (100 mm × 1.8 mm i.d) by a slurry-packing method. The developed columns were used for the separation of peptides and proteins. A separation efficiency (N) of 40,000 plates/column (400,000 plates/m) was achieved for the mixture of five peptides. Similarly, the fast separation of the peptides was carried out using a high flow rate, and the separation of the five peptides was achieved in one minute with high efficiency (N ≅ 240,000 plates/m). The limit of detection (DL) and the limit of quantification (QL) for each analyte were determined by developing a linear regression curve with relatively very low concentrations of the target compound. The average values of the QL for the peptide and proteins were 0.55 ng and 0.48 ng, respectively, using short C18 column (1.8 mm × 100 mm) UV (at 214 nm). The fast analysis of peptides and proteins with such high efficiency and good resolution has not been reported in the literature yet. Owing to high efficiency, these home-made columns could be used as an alternative to the expensive commercial columns for peptide and protein separation.
Collapse
Affiliation(s)
- Ashraf Ali
- Department of Chemistry, Faculty of Natural Sciences, University of Haripur, Haripur 22062, Khyber Pakhtunkhwa, Pakistan
- Correspondence: or ; Tel.: +92-3471214422
| | - Sarah Alharthi
- Department of Chemistry, College of Science, Taif University, Taif 21944, Saudi Arabia;
| | - Nora Hamad Al-Shaalan
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, Riyadh 11671, Saudi Arabia;
| | - Eman Y. Santali
- Department of Pharmaceutical Chemistry, College of Pharmacy, Taif University, Taif 21944, Saudi Arabia;
| |
Collapse
|
3
|
Preparation of mixed-mode stationary phase for separation of peptides and proteins in high performance liquid chromatography. Sci Rep 2022; 12:4061. [PMID: 35260726 PMCID: PMC8904576 DOI: 10.1038/s41598-022-08074-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 03/01/2022] [Indexed: 12/31/2022] Open
Abstract
Porous silica particles were prepared by sol–gel method with some modification to get wide-pore particles. These particles were derivatized with N-phenylmaleimide-methylvinylisocyanate (PMI) and styrene by reversible addition fragmentation chain transfer (RAFT) polymerization to prepare N-phenylmaleimide embedded polystyrene (PMP) stationary phases. Narrow bore stainless steel column (100 × 1.8 mm i.d) was packed by slurry packing method. The chromatographic performance of PMP column was evaluated for the separation of synthetic peptides mixture composed of five peptides (Gly-Tyr, Gly-Leu-Tyr, Gly-Gly-Tyr-Arg, Tyr-Ile-Gly-Ser-Arg, Leucine enkephalin) and tryptic digest of human serum albumin (HAS) respectively. Number of theoretical plates as high as 280,000 plates/m were obtained for peptides mixture at optimum elution condition. Separation performance of the developed column was compared with commercial Ascentis Express RP-Amide column and it was observed that separation performance of PMP column was better than commercial column in terms of separation efficiency and resolution.
Collapse
|
4
|
Lu Y, Yan Z, Sun G. Fast liquid chromatography method for separation of peptides using a sub-2 μm ground silica monolith packed column. J Sep Sci 2021; 44:4123-4131. [PMID: 34535951 DOI: 10.1002/jssc.202100504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 09/03/2021] [Accepted: 09/10/2021] [Indexed: 11/08/2022]
Abstract
A stationary phase based on sub-2 μm ground silica monolith particles was fabricated by in situ polymerization and applied in micro-column for separation of peptides. The sub-2 μm silica particles were obtained from monolith using sol-gel process followed by grinding and sedimentation to remove the fines. Initially, the silica monolith particles were pretreated with 3-trimethoxysilyl propyl methacrylate to attach double-bonded ligands onto the surface, then a network structure was formed onto the surface of the particle using styrene, N-isopropylacrylamide, and ethylene glycoldimethacrylate. The effect of the flow rate of the mobile phase on the separation performance was investigated. The stationary phase was characterized by field emission scanning electron microscopy, thermogravimetry, particle size distribution, and element analysis. The resultant phase was packed in glass-lined stainless steel micro-columns (2.1 mm × 50 mm) and evaluated for fast separation. An average number of theoretical plates as high as 9800 plates/column (5.10 μm plate height) was achieved for five synthetic peptides under the optimized flow rate of 0.15 mL/min. The repeatabilities of column-to-column, intraday, and interday through relative standard deviation were found better than 4%, exhibiting satisfactory repeatability of the developed micro-column for fast separation of peptides.
Collapse
Affiliation(s)
- Yao Lu
- Department of pharmacy, Jiangxi University of Traditional Chinese Medicine, Nanchang, China
| | - Zhihong Yan
- Department of pharmacy, Jiangxi University of Traditional Chinese Medicine, Nanchang, China
| | - Genlin Sun
- Department of pharmacy, Jiangxi University of Traditional Chinese Medicine, Nanchang, China
| |
Collapse
|
5
|
Ali F, AlOthman ZA, Al-Shaalan NH. Mixed-mode open tubular column for peptide separations by capillary electrochromatography. J Sep Sci 2021; 44:2602-2611. [PMID: 33905621 DOI: 10.1002/jssc.202100116] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 04/03/2021] [Accepted: 04/20/2021] [Indexed: 01/01/2023]
Abstract
Mixed-mode chromatography open tubular column has been developed for peptide separation in electrochromatography. A column with 92 cm effective length and 50 μm internal diameter is fabricated internally with a copolymer sheet of restricted thickness. Catalyst facilitated binding of the coupling agent 3,5-bis (trifluoromethyl) phenyl isocyanate has been carried out at the interior surface of the column. The initiator sodium diethyldithiocarbamate was bound to the coupling agent. A small amount of N-[2-(acryloylamino) phenyl] acrylamide was used along with methacrylic acid and styrene in the monomer mixture to induce a little polar character in the stationary phase fabricated inside the column. Twenty-three peptides have been separated from a chemically digested protein mixture present in cytochrome C in capillary electrochromatography, in addition to the separation of six commercial peptides. We achieved an average plate count of over 1.5 million/m with the column of current study both for the digested protein components and commercial peptides using 70/30% v/v (acetonitrile/20 mM ammonium formate) at pH 6.5. In addition, the column resulted in baseline separation of all the peptides with very good resolution, enhanced peak capacity, and better retention time span.
Collapse
Affiliation(s)
- Faiz Ali
- Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan
| | - Zeid A AlOthman
- Advanced Materials Research Chair, Department of Chemistry, College of Science, King Saud University, Riyadh, Saudi Arabia
| | - Nora Hamad Al-Shaalan
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia
| |
Collapse
|
6
|
Characterization and comparison of mixed-mode and reversed-phase columns; interaction abilities and applicability for peptide separation. J Chromatogr A 2021; 1648:462182. [PMID: 33979757 DOI: 10.1016/j.chroma.2021.462182] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 04/15/2021] [Accepted: 04/18/2021] [Indexed: 12/16/2022]
Abstract
In this work, two mixed-mode columns from a different manufacturers and one marketed as a reversed-phase column were characterized and compared in the terms of their interaction abilities, retentivity, peak symmetry, and applicability for peptide separation. All the tested columns contain octadecyl ligand and positively charged modifier, i.e. pyridyl group for the reversed-phase column XSelect CSH C18, quaternary alkylamine for mixed-mode column Atlantis PREMIER BEH C18 AX, and permanently charged moiety (details not available from the manufacturer) for mixed-mode column Luna Omega PS C18. For detailed characterization and comparison of their interaction potential, several approaches were used. First, a simple Walters test was performed to estimate hydrophobic and silanophilic interactions of the tested columns. The highest values of both parameters were observed for column Atlantis PREMIER BEH C18 AX. To investigate the effect of pH and buffer concentration on retention, mobile phases composed of acetonitrile and buffer (ammonium formate, pH 3.0; ammonium acetate pH 4.7 and pH 6.9) in various concentrations (5mM; 10mM; 15mM and 20mM) were used. The analysis of permanently charged compounds was used to describe the electrostatic interaction abilities of the stationary phases. The most significant contribution of electrostatic interactions to the retention was observed for Atlantis PREMIER BEH C18 AX column in the mobile phase with buffer of pH 3.0. A set of ten dipeptides, three pentapeptides and one octapeptide was used to investigate the effects of pH and buffer concentration on retention and peak symmetry. Each of the tested columns provides the optimal peak shape under different buffer pH and concentration. The gradient separation of the 14 tested peptides was used to verify the application potential of the tested columns for peptide separation. The best separation was achieved within 4 minutes on column Atlantis PREMIER BEH C18 AX.
Collapse
|
7
|
Ali F, Cheong WJ, Rafique A, AlOthman ZA, Sadia M, Muhammad M. Particle packed mixed-mode chromatographic stationary phase for the separation of peptide in liquid chromatography. J Sep Sci 2021; 44:1430-1439. [PMID: 33492780 DOI: 10.1002/jssc.202100001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2021] [Revised: 01/20/2021] [Accepted: 01/21/2021] [Indexed: 11/09/2022]
Abstract
A particle-based stationary phase has been prepared for the separation of five synthetic peptides and a mixture containing tryptic digest of cytochrome C in liquid chromatography. Particles originating from silica monolith were differentially sedimented to obtain 1-2 μm particles. A stationary phase was achieved by the coating of poly(styrene-methacrylic acid-N-phenylacrylamide) copolymer onto the particles via reversible addition-fragmentation chain transfer polymerization reaction. Stainless steel column (30 cm long and 1 mm internal diameter) was packed with stationary phase. Very high separation efficiency (ca. 351 000 plates/m) was achieved for five commercial peptides with a percent relative standard deviation of less than 1%. Protocol for the synthesis and modification of silica monolith particles has been well optimized with a good reproducibility both in particle and pore size. The column resolved about 21 peptide components from a mixture containing tryptic digest of cytochrome C, under the elution conditions of acetonitrile/15 mM ammonium format (65/35 v/v%) with a flow rate of 28 μL/min.
Collapse
Affiliation(s)
- Faiz Ali
- Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan.,Department of Chemistry, Inha University, Incheon, South Korea
| | - Won Jo Cheong
- Department of Chemistry, Inha University, Incheon, South Korea
| | - Aamra Rafique
- Department of Chemistry, Faculty of Basic and Applied Sciences, University of The Poonch, Rawalakot, Pakistan
| | - Zeid A AlOthman
- Advanced Materials Research Chair, Chemistry Department, College of Science, King Saud University, Riyadh, Saudi Arabia
| | - Maria Sadia
- Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan
| | - Mian Muhammad
- Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan
| |
Collapse
|
8
|
Lu Y, Sun G. Hydroxypropyl-β-cyclodextrin encapsulated stationary phase based on silica monolith particles for enantioseparation in liquid chromatography. J Sep Sci 2020; 44:735-743. [PMID: 33253443 DOI: 10.1002/jssc.202000978] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 11/21/2020] [Accepted: 11/26/2020] [Indexed: 01/13/2023]
Abstract
Hydroxypropyl-β-cyclodextrin-encapsulated stationary phase incorporated on silica monolith particles was prepared by physical embedding, providing a new method for the development of chiral stationary phase for enantioseparation in liquid chromatography. Ground silica monolith particles of about 2.0 μm were prepared via sol-gel reaction followed by differential sedimentation. Initially, the silica monolith particles were pretreated with 3-trimethoxysilyl propyl methacrylate to attach double-bonded ligands onto the surface, then a network structure was formed onto the surface of the particle using N-isopropyl acrylamide as functional monomer. Hydroxypropyl-β-cyclodextrin was encapsulated inside N-isopropyl acrylamide copolymerized layer on the surface of silica monolith particles. The effect of the amount of chiral selector on the chromatographic efficiency of the chiral stationary phase was examined. The glass lined stainless steel columns (1 mm internal diameter, 300 mm length) were packed with the stationary phase for estimation of the efficiency by separation of phenylsuccinic acid, oxybutynin, equol, and naproxen enantiomers in high-performance liquid chromatography, with the resolutions of 1.54, 1.72, 2.54, and 2.31, respectively. The column to column repeatabilities through relative standard deviation were found better than 3%. The experimental results indicate that the sol-gel ground silica particles modified with β-cyclodextrin provide a promising way for the separation of chiral enantiomers.
Collapse
Affiliation(s)
- Yao Lu
- Department of pharmacy, Jiangxi University of Traditional Chinese Medicine, Nanchang, P. R. China
| | - Genlin Sun
- Department of pharmacy, Jiangxi University of Traditional Chinese Medicine, Nanchang, P. R. China
| |
Collapse
|
9
|
Saad MN, Essam HM, Elzanfaly ES, Amer SM. A Two-Step Optimization Approach: Validated RP-HPLC Method for Determination of Gatifloxacin and Dexamethasone in Ophthalmic Formulation. J Chromatogr Sci 2020; 58:504-510. [PMID: 32280954 DOI: 10.1093/chromsci/bmaa013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 02/10/2020] [Accepted: 02/25/2020] [Indexed: 01/02/2023]
Abstract
The growing technology of stationary phase chemistry has a great impact on the chromatographic system performance and analysis economics. In this context, a simple rapid reversed phase high-performance liquid chromatography method development is presented for the analysis of gatifloxacin (GFN) and dexamethasone sodium phosphate (DSP) in their ophthalmic formulation. A two-step optimization approach has been conducted using optimum chromatographic conditions as well as proper selection of stationary phase. The chromatographic separation was carried out using sodium phosphate buffer pH 3.0 ± 0.1 and acetonitrile 72:28 v/v, respectively, with flow rate 1 mL min-1 and simultaneous detection at 243 nm. Three different column technologies were investigated at the optimum set of the chromatographic conditions: Xbridge® bridged ethylene hybrid silica, Kinetex™ Core-Shell and the Onyx™ Monolithic stationary phase. The monolithic column has shown better chromatographic separation, based on system suitability testing as well as shorter analysis time and sensitivity. The proposed method was validated according to International Conference on Harmonization guidelines. The linearity was achieved for GFN and DSP in the range 0.58-120 μg mL-1 and 0.50-120 μg mL-1, respectively, with acceptable accuracy, precision and selectivity.
Collapse
Affiliation(s)
- Martin N Saad
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| | - Hebatallah M Essam
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| | - Eman S Elzanfaly
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| | - Sawsan M Amer
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo 11562, Egypt
| |
Collapse
|