Nakanishi K, Fujita N, Abe S, Nishii R, Kato K. A simple method to shorten the apparent dead time in the dosimetry of Lu-177 for targeted radionuclide therapy using a gamma camera. Phys Med 2024; 119:103298. [PMID: 38309102 DOI: 10.1016/j.ejmp.2024.103298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 12/04/2023] [Accepted: 01/23/2024] [Indexed: 02/05/2024] Open
Abstract
BACKGROUND The dead-time loss reportedly degrades the accuracy of dosimetry using a gamma camera for targeted radionuclide therapy with Lu-177; therefore, the dead-time loss needs to be corrected. However, the correction is challenging. In this study, we propose a novel and simple method to shorten the apparent dead time rather than correcting it through experiments and Monte Carlo simulations. METHODS An energy window of 208 keV ± 10 % is generally used for the imaging of Lu-177. Lower-energy gamma photons and X-rays of Lu-177 do not contribute to image formation but lead to dead-time losses. In our proposed method, a thin lead sheet was used to shield gamma photons and X-rays with energies lower than 208 keV, while detecting 208 keV gamma photons that penetrated the thin sheet. We measured and simulated the energy spectra and count rate characteristics of a clinical gamma camera system using a cylindrical phantom filled with a Lu-177 solution. Lead sheets of 1.0- and 0.5-mm thicknesses were used as thin shields, and the dead-time losses in tumour imaging with consumed Lu-177 were simulated. RESULTS The apparent dead times with lead sheets of 1.0- and 0.5-mm thicknesses and without a lead sheet were 1.7, 1.9, and 5.8 µs for an energy window of 208 keV ± 10 %, respectively. The dead-time losses could be reduced from 10 % to 1.3 % using the 1.0-mm thick lead sheet in the simulated imaging of tumour. CONCLUSION Our method is promising in clinical situations and studies on Lu-177 dosimetry for tumours.
Collapse
Affiliation(s)
- Kohei Nakanishi
- Functional Medical Imaging, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan.
| | - Naotoshi Fujita
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan
| | - Shinji Abe
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan
| | - Ryuichi Nishii
- Medical Imaging Engineering, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Katsuhiko Kato
- Functional Medical Imaging, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
2
|
Piccardo A, Treglia G, Fiz F, Bar-Sever Z, Bottoni G, Biassoni L, Borgwardt L, de Keizer B, Jehanno N, Lopci E, Kurch L, Massollo M, Nadel H, Roca Bielsa I, Shulkin B, Vali R, De Palma D, Cecchin D, Santos AI, Zucchetta P. The evidence-based role of catecholaminergic PET tracers in Neuroblastoma. A systematic review and a head-to-head comparison with mIBG scintigraphy. Eur J Nucl Med Mol Imaging 2024; 51:756-767. [PMID: 37962616 PMCID: PMC10796700 DOI: 10.1007/s00259-023-06486-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 10/21/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Molecular imaging is pivotal in staging and response assessment of children with neuroblastoma (NB). [123I]-metaiodobenzylguanidine (mIBG) is the standard imaging method; however, it is characterised by low spatial resolution, time-consuming acquisition procedures and difficult interpretation. Many PET catecholaminergic radiotracers have been proposed as a replacement for [123I]-mIBG, however they have not yet made it into clinical practice. We aimed to review the available literature comparing head-to-head [123I]-mIBG with the most common PET catecholaminergic radiopharmaceuticals. METHODS We searched the PubMed database for studies performing a head-to-head comparison between [123I]-mIBG and PET radiopharmaceuticals including meta-hydroxyephedrine ([11C]C-HED), 18F-18F-3,4-dihydroxyphenylalanine ([18F]DOPA) [124I]mIBG and Meta-[18F]fluorobenzylguanidine ([18F]mFBG). Review articles, preclinical studies, small case series (< 5 subjects), case reports, and articles not in English were excluded. From each study, the following characteristics were extracted: bibliographic information, technical parameters, and the sensitivity of the procedure according to a patient-based analysis (PBA) and a lesion-based analysis (LBA). RESULTS Ten studies were selected: two regarding [11C]C-HED, four [18F]DOPA, one [124I]mIBG, and three [18F]mFBG. These studies included 181 patients (range 5-46). For the PBA, the superiority of the PET method was reported in two out of ten studies (both using [18F]DOPA). For LBA, PET detected significantly more lesions than scintigraphy in seven out of ten studies. CONCLUSIONS PET/CT using catecholaminergic tracers shows superior diagnostic performance than mIBG scintigraphy. However, it is still unknown if such superiority can influence clinical decision-making. Nonetheless, the PET examination appears promising for clinical practice as it offers faster image acquisition, less need for sedation, and a single-day examination.
Collapse
Affiliation(s)
- Arnoldo Piccardo
- Department of Nuclear Medicine, E.O. "Ospedali Galliera", Mura Delle Cappuccine 14, 16128, Genoa, Italy.
| | - Giorgio Treglia
- Clinic of Nuclear Medicine, Imaging Institute of Southern Switzerland, Ente Ospedaliero Cantonale, Bellinzona, Switzerland
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
- Faculty of Biomedical Sciences, Università Della Svizzera Italiana, Lugano, Switzerland
| | - Francesco Fiz
- Department of Nuclear Medicine, E.O. "Ospedali Galliera", Mura Delle Cappuccine 14, 16128, Genoa, Italy
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital, Tübingen, Germany
| | - Zvi Bar-Sever
- Department of Nuclear Medicine, Schneider Children's Medical Center, Tel Aviv University, Tel Aviv, Israel
| | - Gianluca Bottoni
- Department of Nuclear Medicine, E.O. "Ospedali Galliera", Mura Delle Cappuccine 14, 16128, Genoa, Italy
| | - Lorenzo Biassoni
- Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK
| | - Lise Borgwardt
- Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Bart de Keizer
- Department of Nuclear Medicine and Radiology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Nina Jehanno
- Department of Nuclear Medicine, Institut Curie Paris, Paris, France
| | - Egesta Lopci
- Nuclear Medicine Unit, IRCCS-Humanitas Research Hospital, Rozzano, Milano, Italy
| | - Lars Kurch
- Department of Nuclear Medicine, University Hospital Leipzig, Leipzig, Germany
| | - Michela Massollo
- Department of Nuclear Medicine, E.O. "Ospedali Galliera", Mura Delle Cappuccine 14, 16128, Genoa, Italy
| | - Helen Nadel
- Department of Pediatric Nuclear Medicine, Lucile Packard Children's Hospital of Stanford (CA), Palo Alto, USA
| | | | - Barry Shulkin
- St Jude Children's Research Hospital, Memphis, TN, USA
| | - Reza Vali
- Division of Nuclear Medicine, Department of Diagnostic Imaging, The Hospital for Sick Children of Toronto, Toronto, Canada
| | - Diego De Palma
- Nuclear Medicine Unit, Ospedale Di Circolo of Varese, Varese, Italy
| | - Diego Cecchin
- Nuclear Medicine Unit, Department of Medicine - DIMED, University Hospital of Padova, Padua, Italy
| | - Ana Isabel Santos
- Department of Nuclear Medicine, Hospital Garcia de Orta, Almada, Portugal
| | - Pietro Zucchetta
- Nuclear Medicine Unit, Department of Medicine - DIMED, University Hospital of Padova, Padua, Italy
| |
Collapse
|
3
|
Moraitis A, Jentzen W, Reiter G, Schmitz J, Pöppel TD, Weber M, Herrmann K, Fendler WP, Fragoso Costa P, Bockisch A, Kersting D. Biodistribution and radiation dosimetry of 124I-mIBG in adult patients with neural crest tumours and extrapolation to paediatric models. EJNMMI Phys 2024; 11:3. [PMID: 38167953 PMCID: PMC10761661 DOI: 10.1186/s40658-023-00604-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 12/20/2023] [Indexed: 01/05/2024] Open
Abstract
AIM Positron emission tomography (PET) using 124I-mIBG has been established for imaging and pretherapeutic dosimetry. Here, we report the first systematic analysis of the biodistribution and radiation dosimetry of 124I-mIBG in patients with neural crest tumours and project the results to paediatric patient models. METHODS Adult patients with neural crest tumours who underwent sequential 124I-mIBG PET were included in this retrospective single-center analysis. PET data were acquired 4, 24, 48, and/or 120 h after administration of a mean of 43 MBq 124I-mIBG. Whole-body counting and blood sampling were performed at 2, 4, 24, 48 and 120 h after administration. Absorbed organ dose and effective dose coefficients were estimated in OLINDA/EXM 2.2 according to the MIRD formalism. Extrapolation to paediatric models was performed based on mass-fraction scaling of the organ-specific residence times. Biodistribution data for adults were also projected to 123I-mIBG and 131I-mIBG. RESULTS Twenty-one patients (11 females, 10 males) were evaluated. For adults, the organs exposed to the highest dose per unit administered activity were urinary bladder (1.54 ± 0.40 mGy/MBq), salivary glands (0.77 ± 0.28 mGy/MBq) and liver (0.65 ± 0.22 mGy/MBq). Mean effective dose coefficient for adults was 0.25 ± 0.04 mSv/MBq (male: 0.24 ± 0.03 mSv/MBq, female: 0.26 ± 0.06 mSv/MBq), and increased gradually to 0.29, 0.44, 0.69, 1.21, and 2.94 mSv/MBq for the 15-, 10-, 5-, 1-years-old, and newborn paediatric reference patients. Projected mean effective dose coefficients for 123I-mIBG and 131I-mIBG for adults were 0.014 ± 0.002 mSv/MBq and 0.18 ± 0.04 mSv/MBq, respectively. CONCLUSION PET-based derived radiation dosimetry data for 124I-mIBG from this study agreed well with historical projected data from ICRP 53. The effective dose coefficients presented here may aid in guidance for establishing weight-based activity administration protocols.
Collapse
Affiliation(s)
- Alexandros Moraitis
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany.
| | - Walter Jentzen
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Gloria Reiter
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Jochen Schmitz
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Thorsten Dirk Pöppel
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Manuel Weber
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Ken Herrmann
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Wolfgang Peter Fendler
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Pedro Fragoso Costa
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Andreas Bockisch
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - David Kersting
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| |
Collapse
|
4
|
Lai HA, Sharp SE, Bhatia A, Dietz KR, McCarville B, Rajderkar D, Servaes S, Shulkin BL, Singh S, Trout AT, Watal P, Parisi MT. Imaging of pediatric neuroblastoma: A COG Diagnostic Imaging Committee/SPR Oncology Committee White Paper. Pediatr Blood Cancer 2023; 70 Suppl 4:e29974. [PMID: 36184716 PMCID: PMC10680359 DOI: 10.1002/pbc.29974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 08/17/2022] [Indexed: 11/07/2022]
Abstract
Neuroblastoma is the most common extracranial solid neoplasm in children. This manuscript provides consensus-based imaging recommendations for pediatric neuroblastoma patients at diagnosis and during follow-up.
Collapse
Affiliation(s)
- Hollie A. Lai
- Department of Radiology, Children’s Health Orange County, Orange, CA
| | - Susan E. Sharp
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH
| | - Aashim Bhatia
- Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, PA
| | - Kelly R. Dietz
- Department of Radiology, University of Minnesota, Minneapolis, MN
| | - Beth McCarville
- Department of Diagnostic Imaging, St. Jude Children’s Research Hospital, Memphis, TN
| | | | - Sabah Servaes
- Department of Radiology, West Virginia University Children’s Hospital, Morgantown, WV
| | - Barry L. Shulkin
- Department of Diagnostic Imaging, University of TN Health Science Center, St. Jude Children’s Research Hospital, Memphis, TN
| | - Sudha Singh
- Department of Radiology, Monroe Carrell Jr Children’s Hospital, Vanderbilt University, Nashville, TN
| | - Andrew T. Trout
- Department of Radiology, Cincinnati Children’s Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH
| | - Pankaj Watal
- Department of Radiology, Nemours Children’s Hospital, Florida and University of Central Florida College of Medicine, Orlando, FL
| | - Marguerite T. Parisi
- Departments of Radiology and Pediatrics, University of Washington School of Medicine and Seattle Children’s Hospital, Seattle, WA
| |
Collapse
|
5
|
Abstract
PURPOSE OF REVIEW In recent years, a broad spectrum of molecular image biomarkers for assessment of adrenal functional imaging have penetrated the clinical arena. Those include positron emission tomography and single photon emission computed tomography radiotracers, which either target glucose transporter, CYP11B enzymes, C-X-C motif chemokine receptor 4, norepinephrine transporter or somatostatin receptors. We will provide an overview of key radiopharmaceuticals and determine their most relevant clinical applications, thereby providing a roadmap for the right image biomarker at the right time for the right patient. RECENT FINDINGS Numerous radiotracers for assessment of adrenal incidentalomas ([18F]FDG; [123I]IMTO/IMAZA), ACC ([123I]IMTO/IMAZA; [18F]FDG; [68Ga]PentixaFor), pheochromocytomas and paragangliomas ([123I]mIBG; [18F]flubrobenguane; [18F]AF78; [68Ga]DOTATOC/-TATE), or primary aldosteronism ([11C]MTO, [68Ga]PentixaFor) are currently available and have been extensively investigated in recent years. In addition, the field is currently evolving from adrenal functional imaging to a patient-centered adrenal theranostics approach, as some of those radiotracers can also be labeled with ß-emitters for therapeutic purposes. SUMMARY The herein reviewed functional image biomarkers may not only allow to increase diagnostic accuracy for adrenal gland diseases but may also enable for achieving substantial antitumor effects in patients with adrenocortical carcinoma, pheochromocytoma or paraganglioma.
Collapse
|
6
|
Ichikawa H. [[Nuclear Medicine] 4. Phantom Studies in Oncology]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:637-645. [PMID: 35718453 DOI: 10.6009/jjrt.2022-2038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Affiliation(s)
- Hajime Ichikawa
- Department of Radiology, Toyohashi Municipal Hospital
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University
| |
Collapse
|
7
|
Wikberg E, van Essen M, Rydén T, Svensson J, Gjertsson P, Bernhardt P. EVALUATION OF THE SPATIAL RESOLUTION IN MONTE CARLO-BASED SPECT/CT RECONSTRUCTION OF 111IN-OCTREOTIDE IMAGES. RADIATION PROTECTION DOSIMETRY 2021; 195:319-326. [PMID: 33885133 PMCID: PMC8507452 DOI: 10.1093/rpd/ncab055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 02/23/2021] [Accepted: 03/30/2021] [Indexed: 06/03/2023]
Abstract
The purpose was to evaluate the spatial resolution in 111In-octreotide single-photom emission computed tomography (SPECT)/computed tomography (CT) imaging following reconstructions with three different ordered subset expectation maximizations (OSEM) reconstruction algorithms; attenuation corrected (AC) OSEM, AC OSEM with resolution recovery (ACRR OSEM) and Monte Carlo-based OSEM reconstruction (MC OSEM). SPECT/CT imaging of a triple line phantom containing 111In in air and water was performed. The spatial resolution, represented by the full width at half maximum (FWHM) of a line profile, was determined for each line, for X and Y direction and for all reconstructions. The mean FWHM was 12.2 mm (±standard deviation [SD] 3.7 mm) for AC OSEM, 9.3 mm (±SD 2.5 mm) for ACRR OSEM and 8.2 mm (±SD 2.0 mm) for MC OSEM. MC-based SPECT/CT reconstruction clearly improves the spatial resolution in 111In-octreotide imaging and since MC simulations can be performed for all photon energies MC OSEM has the potential to improve SPECT/CT imaging overall.
Collapse
Affiliation(s)
- Emma Wikberg
- Department of Medical Radiation Sciences, Sahlgrenska Academy, Gothenburg University, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
- Medical Physics and Medical Bioengineering, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
| | - Martijn van Essen
- Department of Clinical Physiology, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
| | - Tobias Rydén
- Medical Physics and Medical Bioengineering, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
| | - Johanna Svensson
- Department of Oncology, Sahlgrenska Academy, Gothenburg University, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
| | - Peter Gjertsson
- Department of Clinical Physiology, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
| | - Peter Bernhardt
- Department of Medical Radiation Sciences, Sahlgrenska Academy, Gothenburg University, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
- Medical Physics and Medical Bioengineering, Sahlgrenska University Hospital, 413 45, Gothenburg, Sweden
| |
Collapse
|
8
|
Weber M, Schmitz J, Maric I, Pabst KM, Umutlu L, Walz M, Herrmann K, Rischpler C, Weber F, Jentzen W, Theurer S, Poeppel TD, Unger N, Fendler WP. Diagnostic performance of [ 124I]m-iodobenzylguanidine PET/CT in patients with pheochromocytoma. J Nucl Med 2021; 63:869-874. [PMID: 34556526 DOI: 10.2967/jnumed.121.262797] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 09/08/2021] [Indexed: 11/16/2022] Open
Abstract
123/131I-MIBG scintigraphy has shown a high specificity for imaging pheochromocytoma and paraganglioma however with low sensitivity due to low spatial resolution. 124I-MIBG PET may overcome this limitation to improve the staging of patients with (suspected) pheochromocytoma. Methods: We analyzed the sensitivity, specificity, positive and negative predictive values (PPV, NPV) of 124I-MIBG PET in 43 consecutive patients with suspected (recurrence of) pheochromocytoma using histopathological (n = 25) and clinical validation (n = 18) as standard of truth. Furthermore, we compared 124I-MIBG PET versus contrast enhanced CT (CE-CT) per-patient and per-lesion detection rate of 124I-MIBG PET in 13 additional patients with known metastatic malignant pheochromocytoma (MMP). Results: 124I-MIBG PET/CT was positive in 19/43 (44%) patients with suspected pheochromocytoma. Presence of pheochromocytoma was confirmed in 22/43 (51%). 124I-MIBG PET/CT sensitivity, specificity, PPV, NPV were 86%, 100%, 100%, 88%, respectively. 124I-MIBG PET was positive in 11/13 (85%) MMP patients. Combined 124I-MIBG PET and CE-CT detected 173 lesions, of which 166 (96%) and 118 (68%) were visible on 124I-MIBG PET and CE-CT, respectively. Discussion: 124I-MIBG PET detects pheochromocytoma with high accuracy at initial staging and high detection rate at re-staging. Superior diagnostic performance aids guidance of surgical and medical management including personalized 131I-MIBG therapy.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | - Nicole Unger
- University Hospital Essen Clinic for Endocrinology
| | | |
Collapse
|
9
|
Fanchon LM, Beattie BJ, Pentlow K, Larson SM, Humm JL. Optimizing reconstruction parameters for quantitative 124I-PET in the presence of therapeutic doses of 131I. EJNMMI Phys 2021; 8:50. [PMID: 34250566 PMCID: PMC8273044 DOI: 10.1186/s40658-021-00398-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 06/23/2021] [Indexed: 11/11/2022] Open
Abstract
Background The goal of this work was to determine the quantitative accuracy and optimal reconstruction parameters for 124I-PET imaging in the presence of therapeutic levels of 131I. In this effort, images were acquired on a GE D710 PET/CT scanner using a NEMA IEC phantom with spheres containing 124I and increasing amounts of 131I activity in the background. At each activity level, two scans were acquired, one with the phantom centered in the field of view (FOV) and one 11.2 cm off-center. Reconstructions used an ordered subset expectation maximization algorithm with up to 100 iterations of 16 subsets, with and without time-of-flight (TOF) information. Results were evaluated visually and by comparing the 124I activity relative to the scan performed in the absence of 131I. Results 131I within the FOV added to the randoms rate, to dead time, and to pile-up within the detectors. Using our standard clinical reconstruction parameters, the image quality and quantitative accuracy suffered at 131I activities above 1.4 GBq. Convergence rates slowed progressively in the presence of increasing amounts of 131I for both TOF and nonTOF reconstructions. TOF reconstructions converged more quickly than nonTOF but often towards erroneous concentrations. Iterating nonTOF reconstructions to convergence produced quantitatively accurate images except for the off-center phantom at the very highest level of background 131I tested. Conclusions This study shows that quantitative PET is feasible in the presence of large amounts of 131I. The high randoms fractions resulted in slow reconstruction convergence and negatively impacted TOF corrections and/or the accuracy of TOF information. Therefore, increased iterations and nonTOF reconstructions are recommended. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00398-z.
Collapse
Affiliation(s)
- Louise M Fanchon
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Bradley J Beattie
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Keith Pentlow
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Steven M Larson
- Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - John L Humm
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA.
| |
Collapse
|
10
|
Automatic quantification package (Hone Graph) for phantom-based image quality assessment in bone SPECT: computerized automatic classification of detectability. Ann Nucl Med 2021; 35:937-946. [PMID: 34028702 DOI: 10.1007/s12149-021-01631-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 05/12/2021] [Indexed: 01/12/2023]
Abstract
OBJECTIVE We previously developed a custom-design thoracic bone scintigraphy-specific phantom ("SIM2 bone phantom") to assess image quality in bone single-photon emission computed tomography (SPECT). We aimed to develop an automatic assessment system for imaging technology in bone SPECT and demonstrate the validity of this system. METHODS Four spherical lesions of 13-, 17-, 22-, and 28-mm diameters in the vertebrae of SIM2 bone phantom simulating the thorax were filled with radioactivity (target-to-background ratio: 4). Dynamic SPECT acquisitions were performed for 15 min; reconstructions were performed using ordered subset expectation maximization at 3-15-min timepoints. Consequently, 216 lesions (54 SPECT images) were obtained: 120 and 96 lesions were used for software development and validation, respectively. The developed software used statistical parametric mapping to rigidly register and automatically calculate quantitative indexes (contrast-to-noise ratio, % coefficient of variance, % detectability equivalence volume, recovery coefficient, target-to-normal bone ratio, and full width at half maximum). A detectability score (DS) was used to define the four observation types (4, excellent; 3, adequate; 2, average; 1, poor) to score hot spherical lesions. The gold standard for DSs was independently classified by three experienced board-certified nuclear medicine technologists using the four observation types; thereafter, a consensus regarding the gold standard for DSs was reached. Using 120 lesions for development, decision tree analysis was performed to determine DS based on the quantitative indexes. We verified the validation of the quantitative indexes and their threshold values for automatic classification using 96 lesions for validation. RESULTS The trends in the automatically calculated quantitative indices were consistent. Decision tree analysis produced four terminal groups; two quantitative indexes (% detectability equivalence volume and contrast-to-noise ratio) were used to classify DS. The automatically classified DSs exhibited an almost perfect agreement with the gold standard. The percentage agreement and kappa coefficient were 91.7% and 0.93, respectively, in 96 lesions for validation. CONCLUSIONS The developed software automatically classified the detectability of hot lesions in the SIM2 bone phantom using the automatically calculated quantitative indexes, suggesting that this software could provide a means to automatically perform detectability analysis after data input that is excellent in reproducibility and accuracy.
Collapse
|
11
|
Samim A, Tytgat GA, Bleeker G, Wenker ST, Chatalic KL, Poot AJ, Tolboom N, van Noesel MM, Lam MG, de Keizer B. Nuclear Medicine Imaging in Neuroblastoma: Current Status and New Developments. J Pers Med 2021; 11:jpm11040270. [PMID: 33916640 PMCID: PMC8066332 DOI: 10.3390/jpm11040270] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 04/01/2021] [Indexed: 12/20/2022] Open
Abstract
Neuroblastoma is the most common extracranial solid malignancy in children. At diagnosis, approximately 50% of patients present with metastatic disease. These patients are at high risk for refractory or recurrent disease, which conveys a very poor prognosis. During the past decades, nuclear medicine has been essential for the staging and response assessment of neuroblastoma. Currently, the standard nuclear imaging technique is meta-[123I]iodobenzylguanidine ([123I]mIBG) whole-body scintigraphy, usually combined with single-photon emission computed tomography with computed tomography (SPECT-CT). Nevertheless, 10% of neuroblastomas are mIBG non-avid and [123I]mIBG imaging has relatively low spatial resolution, resulting in limited sensitivity for smaller lesions. More accurate methods to assess full disease extent are needed in order to optimize treatment strategies. Advances in nuclear medicine have led to the introduction of radiotracers compatible for positron emission tomography (PET) imaging in neuroblastoma, such as [124I]mIBG, [18F]mFBG, [18F]FDG, [68Ga]Ga-DOTA peptides, [18F]F-DOPA, and [11C]mHED. PET has multiple advantages over SPECT, including a superior resolution and whole-body tomographic range. This article reviews the use, characteristics, diagnostic accuracy, advantages, and limitations of current and new tracers for nuclear medicine imaging in neuroblastoma.
Collapse
Affiliation(s)
- Atia Samim
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht/Wilhelmina Children’s Hospital, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands;
| | - Godelieve A.M. Tytgat
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
| | - Gitta Bleeker
- Department of Radiology and Nuclear Medicine, Northwest Clinics, Wilhelminalaan 12, 1815 JD Alkmaar, The Netherlands;
| | - Sylvia T.M. Wenker
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht/Wilhelmina Children’s Hospital, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands;
| | - Kristell L.S. Chatalic
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht/Wilhelmina Children’s Hospital, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands;
| | - Alex J. Poot
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht/Wilhelmina Children’s Hospital, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands;
| | - Nelleke Tolboom
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht/Wilhelmina Children’s Hospital, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands;
| | - Max M. van Noesel
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
| | - Marnix G.E.H. Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht/Wilhelmina Children’s Hospital, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands;
| | - Bart de Keizer
- Princess Maxima Center for Pediatric Oncology, Heidelberglaan 25, 3584 CS Utrecht, The Netherlands; (A.S.); (G.A.M.T.); (S.T.M.W.); (K.L.S.C.); (A.J.P.); (N.T.); (M.M.v.N.)
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht/Wilhelmina Children’s Hospital, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands;
- Correspondence: ; Tel.: +31-887-571-794
| |
Collapse
|
12
|
Ferris T, Carroll L, Jenner S, Aboagye EO. Use of radioiodine in nuclear medicine—A brief overview. J Labelled Comp Radiopharm 2020; 64:92-108. [DOI: 10.1002/jlcr.3891] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Revised: 09/06/2020] [Accepted: 10/11/2020] [Indexed: 12/15/2022]
Affiliation(s)
- Trevor Ferris
- Department of Chemistry, Molecular Sciences Research Hub Imperial College London White City Campus London UK
| | - Laurence Carroll
- Russell H. Morgan Department of Radiology and Radiological Sciences Johns Hopkins Medical Institutions Baltimore Maryland USA
| | | | - Eric O. Aboagye
- Comprehensive Cancer Imaging Centre, Department of Surgery and Cancer Imperial College, Hammersmith Campus London UK
| |
Collapse
|
13
|
Pictorial review of the clinical applications of MIBG in neuroblastoma: current practices. Clin Transl Imaging 2020. [DOI: 10.1007/s40336-020-00392-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
14
|
Pibida L, Bergeron DE, Zimmerman B, Fitzgerald R, Cessna JT, King L. Determination of the half-life and the absolute photon emission intensities for the main gamma-ray energies of 124I. Appl Radiat Isot 2020; 167:109455. [PMID: 33039762 DOI: 10.1016/j.apradiso.2020.109455] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 09/16/2020] [Accepted: 10/01/2020] [Indexed: 11/18/2022]
Abstract
The National Institute of Standards and Technology (NIST) performed new standardization measurements for 124I. As part of this work the absolute photon emission intensity for the main gamma-rays of 124I were determined using several high-purity germanium (HPGe) detectors. In addition, the half-life for 124I was also determined using an HPGe detector. Ionization chamber measurements were performed for additional sources, but it was not possible to obtain a precise half-life value.
Collapse
Affiliation(s)
- L Pibida
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA.
| | - D E Bergeron
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - B Zimmerman
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - R Fitzgerald
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - J T Cessna
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - L King
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| |
Collapse
|
15
|
Huizing DMV, Sinaasappel M, Dekker MC, Stokkel MPM, de Wit – van der Veen BJ. 177
Lutetium SPECT/CT: Evaluation of collimator, photopeak and scatter correction. J Appl Clin Med Phys 2020; 21:272-277. [PMID: 32790140 PMCID: PMC7497918 DOI: 10.1002/acm2.12991] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 06/26/2020] [Accepted: 07/09/2020] [Indexed: 11/10/2022] Open
Abstract
Purpose The goal of this study was to find the optimal combination of collimator, photopeak and scatter correction for 177Lutetium (177Lu) SPECT/CT imaging. Methods Three experiments [sphere‐to‐background ratios (SBR) 50:1, 10:1, and 2:1] were performed with the NEMA Image Quality phantom filled with 177Lu‐trichloride. SPECT/CT acquisitions were performed with the medium‐energy low‐penetration (MELP) collimator and 99mTc/Krypton collimator. For each acquisition six reconstructions, all with attenuation correction (AC), were made: the 113‐keV photopeak only, the 208‐keV photopeak only and both photopeaks combined, each with or without scatter correction (SC). Image quality was assessed using contrast‐to‐noise ratios (CNR), quantification accuracy by means of recovery coefficients (RCs) and the spatial resolution using line profiles. Results With SBR 50:1 and 10:1, both collimators met the Rose criterion (CNR > 5), whereas the MELP collimator showed a higher CNR for the 2:1 ratio. The RCmean was higher with the MELP collimator, most explicit after the 208‐keV AC/SC reconstruction for all acquisitions. The line profiles showed a better spatial resolution for the MELP collimator and the 208‐keV AC/SC reconstructions. Conclusion 177Lu SPECT/CT image quality and quantification was most optimal when acquired with the MELP collimator and reconstructed using the 208‐keV photopeak, with AC and SC.
Collapse
Affiliation(s)
- Daphne M. V. Huizing
- Department of Nuclear Medicine Netherlands Cancer Institute Amsterdam The Netherlands
| | - Michiel Sinaasappel
- Department of Physics Netherlands Cancer Institute Amsterdam The Netherlands
| | - Marien C. Dekker
- Department of Nuclear Medicine Netherlands Cancer Institute Amsterdam The Netherlands
| | - Marcel P. M. Stokkel
- Department of Nuclear Medicine Netherlands Cancer Institute Amsterdam The Netherlands
| | | |
Collapse
|
16
|
Standardization of I-124 by three liquid scintillation-based methods. Appl Radiat Isot 2019; 154:108849. [PMID: 31465950 DOI: 10.1016/j.apradiso.2019.108849] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 06/15/2019] [Accepted: 08/08/2019] [Indexed: 11/20/2022]
Abstract
A solution of 124I was standardized for activity by 4πβ(LS)-γ(NaI) live-timed anticoincidence (LTAC) counting, with confirmatory measurements by triple-to-double coincidence ratio (TDCR) and CIEMAT-NIST efficiency tracing (CNET) liquid scintillation counting. The LTAC-based standard was shown to be in agreement (within k = 1 uncertainties) with previous measurements at NIST and elsewhere. Calibration settings for radionuclide calibrators were determined and a discrepancy with literature values, partially due to a calibration methodology dependent upon an erroneous setting for 18F, was identified and explained.
Collapse
|
17
|
Abstract
Nuclear medicine has a central role in the diagnosis, staging, response assessment and long-term follow-up of neuroblastoma, the most common solid extracranial tumour in children. These EANM guidelines include updated information on 123I-mIBG, the most common study in nuclear medicine for the evaluation of neuroblastoma, and on PET/CT imaging with 18F-FDG, 18F-DOPA and 68Ga-DOTA peptides. These PET/CT studies are increasingly employed in clinical practice. Indications, advantages and limitations are presented along with recommendations on study protocols, interpretation of findings and reporting results.
Collapse
|
18
|
Beijst C, Kunnen B, Lam MGEH, de Jong HWAM. Technical Advances in Image Guidance of Radionuclide Therapy. J Nucl Med Technol 2017; 45:272-279. [PMID: 29042472 DOI: 10.2967/jnmt.117.190991] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 07/05/2017] [Indexed: 11/16/2022] Open
Abstract
Internal radiation therapy with radionuclides (i.e., radionuclide therapy) owes its success to the many advantages over other, more conventional, treatment options. One distinct advantage of radionuclide therapies is the potential to use (part of) the emitted radiation for imaging of the radionuclide distribution. The combination of diagnostic and therapeutic properties in a set of matched radiopharmaceuticals (sometimes combined in a single radiopharmaceutical) is often referred to as theranostics and allows accurate diagnostic imaging before therapy. The use of imaging benefits treatment planning, dosimetry, and assessment of treatment response. This paper focuses on a selection of advances in imaging technology relevant for image guidance of radionuclide therapy. This involves developments in nuclear imaging modalities, as well as other anatomic and functional imaging modalities. The quality and quantitative accuracy of images used for guidance of radionuclide therapy is continuously being improved, which in turn may improve the therapeutic outcome and efficiency of radionuclide therapies.
Collapse
Affiliation(s)
- Casper Beijst
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and .,Image Sciences Institute, UMC Utrecht, Utrecht, The Netherlands
| | - Britt Kunnen
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and.,Image Sciences Institute, UMC Utrecht, Utrecht, The Netherlands
| | - Marnix G E H Lam
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands; and
| |
Collapse
|