Yadav S, Jiang F, Kurkowska S, Saelee R, Morley A, Feng F, Aggarwal R, Lawhn-Heath C, Uribe C, Hope TA. Assessing Response to PSMA Radiopharmaceutical Therapies with Single SPECT Imaging at 24 Hours After Injection. J Nucl Med 2024; 65:1064-1069. [PMID: 38724282 DOI: 10.2967/jnumed.123.267208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 04/08/2024] [Indexed: 07/03/2024] Open
Abstract
Understanding the relationship between lesion-absorbed dose and tumor response in 177Lu-PSMA-617 radiopharmaceutical therapies (RPTs) remains complex. We aimed to investigate whether baseline lesion-absorbed dose can predict lesion-based responses and to explore the connection between lesion-absorbed dose and prostate-specific antigen (PSA) response. Methods: In this retrospective study, we evaluated 50 patients with 335 index lesions undergoing 177Lu-PSMA-617 RPT, who had dosimetry analysis performed on SPECT/CT at 24 h after cycles 1 and 2. First, we identified the index lesions for each patient and measured the lesion-based absorbed doses. Lesion-based response was calculated after cycle 2. Additionally, PSA50 response (a decline of 50% from baseline PSA) after cycle 2 was also calculated. The respective responses for mean and maximum absorbed doses and prostate-specific membrane antigen (PSMA) volumetric intensity product (VIP-PSMA) at cycles 1 and 2 were termed SPECTmean, SPECTmaximum, and SPECTVIP-PSMA, respectively. Results: Of the 50 patients reviewed, 46% achieved a PSA50 response after cycle 2. Of the 335 index lesions, 58% were osseous, 32% were lymph nodes, and 10% were soft-tissue metastatic lesions. The SPECT lesion-based responses were higher in PSA responders than in nonresponders (SPECTmean response of 46.8% ± 26.1% vs. 26.2% ± 24.5%, P = 0.007; SPECTmaximum response of 45% ± 25.1% vs. 19% ± 27.0%, P = 0.001; SPECTVIP-PSMA response of 49.2% ± 30.3% vs. 14% ± 34.7%, P = 0.0005). An association was observed between PSA response and SPECTVIP-PSMA response (R 2 = 0.40 and P < 0.0001). A limited relationship was found between baseline absorbed dose measured with a 24-h single time point and SPECT lesion-based response (R 2 = 0.05, P = 0.001, and R 2 = 0.03, P = 0.007, for mean and maximum absorbed doses, respectively). Conclusion: In this retrospective study, quantitative lesion-based response correlated with patient-level PSA response. We observed a limited relationship between baseline absorbed dose and lesion-based responses. Most of the variance in response remains unexplained solely by baseline absorbed dose. Establishment of a dose-response relationship in RPT with a single time point at 24 h presented some limitations.
Collapse
Affiliation(s)
- Surekha Yadav
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Fei Jiang
- Department of Epidemiology and Biostatistics, University of California San Francisco, San Francisco, California
| | - Sara Kurkowska
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, British Columbia, Canada
- Department of Nuclear Medicine, Pomeranian Medical University, Szczecin, Poland
| | - Rachelle Saelee
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Amanda Morley
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Felix Feng
- Department of Radiation Oncology, University of California San Francisco, San Francisco, California
| | - Rahul Aggarwal
- Division of Hematology/Oncology, Department of Medicine, University of California San Francisco, San Francisco, California
| | - Courtney Lawhn-Heath
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Carlos Uribe
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, British Columbia, Canada
- Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada
- Department of Molecular Imaging and Therapy, BC Cancer, Vancouver, British Columbia, Canada
| | - Thomas A Hope
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California;
- Department of Radiology, San Francisco VA Medical Center, San Francisco, California; and
- Helen Diller Family Comprehensive Cancer Center, University of California San Francisco, San Francisco, California
| |
Collapse
|
2
|
Pham TP, Presles B, Popoff R, Alberini JL, Vrigneaud JM. Pre-treatment dosimetry in 90Y-SIRT: Is it possible to optimise SPECT reconstruction parameters and calculation methods for accurate dosimetry? Phys Med 2023; 115:103145. [PMID: 37852020 DOI: 10.1016/j.ejmp.2023.103145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 06/03/2023] [Accepted: 09/21/2023] [Indexed: 10/20/2023] Open
Abstract
PURPOSE The aim of this study was (a) to optimise the99mTc-SPECT reconstruction parameters for the pre-treatment dosimetry of90Y-selective internal radiation therapy (SIRT) and (b) to compare the accuracy of clinical dosimetry methods with full Monte-Carlo dosimetry (fMCD) performed with Gate. METHODS To optimise the reconstruction parameters, two hundred reconstructions with different parameters were performed on a NEMA phantom, varying the number of iterations, subsets, and post-filtering. The accuracy of the dosimetric methods was then investigated using an anthropomorphic phantom. Absorbed dose maps were generated using (1) the Partition Model (PM), (2) the Dose Voxel Kernel (DVK) convolution, and (3) the Local Deposition Method (LDM) with known activity restricted to the whole phantom (WP) or to the liver and lungs (LL). The dose to the lungs was calculated using the "multiple DVK" and "multiple LDM" methods. RESULTS Optimal OSEM reconstruction parameters were found to depend on object size and dosimetric criterion chosen (Dmean or DVH-derived metric). The Dmean of all three dosimetric methods was close (≤ 10%) to the Dmean of fMCD simulations when considering large segmented volumes (whole liver, normal liver). In contrast, the Dmean to the small volume (∅=31) was systemically underestimated (12%-25%). For lungs, the "multiple DVK" and "multiple LDM" methods yielded a Dmean within 20% for the WP method and within 10% for the LL method. CONCLUSIONS All three methods showed a substantial degradation of the dose-volume histograms (DVHs) compared to fMCD simulations. The DVK and LDM methods performed almost equally well, with the "multiple DVK" method being more accurate in the lungs.
Collapse
Affiliation(s)
- Tien-Phong Pham
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France.
| | - Benoit Presles
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France
| | - Romain Popoff
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France
| | - Jean-Louis Alberini
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France
| | - Jean-Marc Vrigneaud
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France.
| |
Collapse
|
3
|
Bian J, James JR, Wagner R, Halama J. Quantify total activity by volume-of-interest expansion with clinical SPECT/CT systems, a phantom study. J Appl Clin Med Phys 2022; 24:e13828. [PMID: 36347052 PMCID: PMC9859999 DOI: 10.1002/acm2.13828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 09/02/2022] [Accepted: 10/05/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Quantitative measurements of activity in SPECT are important for radioisotope therapy planning and disease diagnosis. The aim of this manuscript is to develop a robust method to quantify the total activity in a volume-of-interest (VOI) of different quantitative SPECT reconstructions and validate the estimation accuracy. METHODS We customized an IEC body phantom using 3D printing technology and made six sphere inserts of 1-6 cm in diameter with at least 3 cm separation. The activity concentration within the spheres was in the range of patient lesion/organ activity. The background activity was then increased from zero to a sphere/background activity concentration of 8:1, 4:1, and 2:1. SPECT data were acquired with Philips Brightview and GE Discovery 670 SPECT/computed tomography (CT) systems under clinical acquisition protocols. Quantitative SPECT images were reconstructed with Hermes SUV-SPECT (both Philips and GE data) and GE Q.Metrix (GE data only). The quantitative SPECT reconstructions are iterative with scatter, CT attenuation correction, and resolution recovery. We quantified the total activity by expanding the sphere VOI to include a spill-out region. Background correction was applied by sampling a region outside the spill-out region. The true fractions (TFs) (total activity/true activity) were measured for all six spheres for all SPECT acquisitions. RESULTS The TF is close to 100% for 2-6 cm spheres for zero background, 8:1 and 4:1 sphere/background activity ratios. The TF was found to be unreliable for the 1-cm sphere because of the limit of phantom design. TF accuracy for 2:1 sphere/background ratio was degraded due to significantly large background, inadequate scatter correction and detector count loss. CONCLUSIONS The results demonstrated that the proposed quantification method is accurate for objects of different sizes in currently clinical quantitative reconstruction and has the potential for improving the accuracy for therapeutic treatment planning or radiation dosimetry calculations.
Collapse
Affiliation(s)
- Junguo Bian
- Department of RadiologyLoyola University Medical CenterMaywoodIllinoisUSA
| | - Judy R James
- Department of RadiologyLoyola University Medical CenterMaywoodIllinoisUSA
| | - Robert Wagner
- Department of RadiologyLoyola University Medical CenterMaywoodIllinoisUSA
| | - James Halama
- Department of RadiologyLoyola University Medical CenterMaywoodIllinoisUSA
| |
Collapse
|
4
|
Lehner S, Nowak I, Zacherl M, Brosch-Lenz J, Fischer M, Ilhan H, Rübenthaler J, Gosewisch A, Bartenstein P, Todica A. Quantitative myocardial perfusion SPECT/CT for the assessment of myocardial tracer uptake in patients with three-vessel coronary artery disease: Initial experiences and results. J Nucl Cardiol 2022; 29:2511-2520. [PMID: 34341952 PMCID: PMC9553851 DOI: 10.1007/s12350-021-02735-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 06/18/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND To evaluate quantitative myocardial perfusion SPECT/CT datasets for routine clinical reporting and the assessment of myocardial tracer uptake in patients with severe TVCAD. METHODS MPS scans were reconstructed as quantitative SPECT datasets using CTs from internal (SPECT/CT, Q_INT) and external (PET/CT, Q_EXT) sources for attenuation correction. TPD was calculated and compared to the TPD from non-quantitative SPECT datasets of the same patients. SUVmax, SUVpeak, and SUVmean were compared between Q_INT and Q_EXT SPECT datasets. Global SUVmax and SUVpeak were compared between patients with and without TVCAD. RESULTS Quantitative reconstruction was feasible. TPD showed an excellent correlation between quantitative and non-quantitative SPECT datasets. SUVmax, SUVpeak, and SUVmean showed an excellent correlation between Q_INT and Q_EXT SPECT datasets, though mean SUVmean differed significantly between the two groups. Global SUVmax and SUVpeak were significantly reduced in patients with TVCAD. CONCLUSIONS Absolute quantification of myocardial tracer uptake is feasible. The method seems to be robust and principally suitable for routine clinical reporting. Quantitative SPECT might become a valuable tool for the assessment of severe coronary artery disease in a setting of balanced ischemia, where potentially life-threatening conditions might otherwise go undetected.
Collapse
Affiliation(s)
- Sebastian Lehner
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany.
- Ambulatory Health Care Center Dr. Neumaier & Colleagues, Radiology, Nuclear Medicine, Radiation Therapy, Bahnhofstraße 24, 93047, Regensburg, Germany.
| | - Isabel Nowak
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| | - Mathias Zacherl
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| | - Julia Brosch-Lenz
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| | - Maximilian Fischer
- Department of Internal Medicine, Cardiology, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| | - Harun Ilhan
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| | | | - Astrid Gosewisch
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| | - Peter Bartenstein
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| | - Andrei Todica
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-Universität, Munich, Germany
| |
Collapse
|
5
|
van Velden FHP, de Geus-Oei LF. Editorial on Special Issue "Quantitative PET and SPECT". Diagnostics (Basel) 2022; 12:1989. [PMID: 36010339 PMCID: PMC9407256 DOI: 10.3390/diagnostics12081989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 08/09/2022] [Accepted: 08/15/2022] [Indexed: 11/26/2022] Open
Abstract
Since the introduction of personalized (or precision) medicine, where individually tailored treatments are designed to deliver the right treatment to the right patient at the right time, the primary focus of imaging has moved from detection and diagnosis to tissue characterization, determination of prognosis, prediction of treatment efficacy, and measurement of treatment response [...].
Collapse
Affiliation(s)
- Floris H. P. van Velden
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
| | - Lioe-Fee de Geus-Oei
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
- Biomedical Photonic Imaging Group, University of Twente, 7522 NB Enschede, The Netherlands
| |
Collapse
|
6
|
Shiiba T, Sekikawa Y, Tateoka S, Shinohara N, Inoue Y, Kuroiwa Y, Tanaka T, Kihara Y, Imamura T. Verification of the effect of acquisition time for SwiftScan on quantitative bone single-photon emission computed tomography using an anthropomorphic phantom. EJNMMI Phys 2022; 9:48. [PMID: 35907090 PMCID: PMC9339048 DOI: 10.1186/s40658-022-00477-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Accepted: 07/20/2022] [Indexed: 11/25/2022] Open
Abstract
Background SwiftScan single-photon emission computed tomography (SPECT) is a recently released scanning technique with data acquired when the detector is stationary and when it moves from one view to the next. The influence of scan time for using SwiftScan on quantitative bone SPECT remains unclear. This study aimed to clarify the effect of the scan time for SwiftScan SPECT on the image quality and quantification of bone SPECT compared to step and shoot mode (SSM) using 99mTc-filled anthropomorphic phantom (SIM2 bone phantom). Materials and methods Phantom SPECT/computed tomography (CT) images were acquired using Discovery NM/CT 860 (GE Healthcare) with a low-energy high-resolution sensitivity collimator. We used the fixed parameters (subsets 10 and iterations 5) for reconstruction. The coefficient of variation (CV), contrast-to-noise ratio (CNR), full width at half maximum (FWHM), and quantitative value of SwiftScan SPECT and SSM were compared at various acquisition times (5, 7, 17, and 32 min). Results In the short-time scan (< 7 min), the CV and CNR of SwiftScan SPECT were better than those of SSM, whereas in the longtime scan (> 17 min), the CV and CNR of SwiftScan SPECT were similar to those of SSM. The FWHMs for SwiftScan SPECT (13.6–14.8 mm) and SSM (13.5–14.4 mm) were similar. The mean absolute errors of quantitative values at 5, 7, 17, and 32 min were 38.8, 38.4, 48.8, and 48.1, respectively, for SwiftScan SPECT and 41.8, 40.8%, 47.2, and 49.8, respectively, for SSM. Conclusions SwiftScan on quantitative bone SPECT provides improved image quality in the short-time scan with quantification similar to or better than SSM. Therefore, in clinical settings, using SwiftScan SPECT instead of the SSM scan protocol in the short-time scan might provide higher-quality diagnostic images than SSM. Our results could provide vital information on the use of SwiftScan SPECT.
Collapse
Affiliation(s)
- Takuro Shiiba
- Department of Molecular Imaging, School of Medical Sciences, Fujita Health University, 1-98, Dengakubo, Kutsukake-cho, Aichi, 470-1192, Toyoake, Japan.
| | - Yuya Sekikawa
- Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University, 6-22 Misakimachi, Omuta-shi, Fukuoka, 836-8505, Japan
| | - Shinji Tateoka
- Department of Radiological Technology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-cho, Miyazaki-shi, Miyazaki, 880-0041, Japan
| | - Nobutaka Shinohara
- Department of Radiological Technology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-cho, Miyazaki-shi, Miyazaki, 880-0041, Japan
| | - Yuuki Inoue
- Department of Radiological Technology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-cho, Miyazaki-shi, Miyazaki, 880-0041, Japan
| | - Yasuyoshi Kuroiwa
- Department of Radiological Technology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-cho, Miyazaki-shi, Miyazaki, 880-0041, Japan.,Department of Pathology, Faculty of Medicine, University of Miyazaki, 5200 Kihara, Kiyotake, Miyazaki, 889-1692, Japan
| | - Takashi Tanaka
- Department of Radiology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-cho, Miyazaki-shi, Miyazaki, 880-0041, Japan
| | - Yasushi Kihara
- Department of Radiology, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-cho, Miyazaki-shi, Miyazaki, 880-0041, Japan
| | - Takuroh Imamura
- Department of Internal Medicine, Koga General Hospital, 1749-1 Sudaki, Ikeuchi-cho, Miyazaki-shi, Miyazaki, 880-0041, Japan
| |
Collapse
|
7
|
Bellevre D, Bailliez A, Delelis F, Blaire T, Agostini D, Mouquet F, Maréchaux S, Manrique A. Quantitation of myocardial 99mTc-HMDP uptake with new SPECT/CT cadmium zinc telluride (CZT) camera in patients with transthyretin-related cardiac amyloidosis: Ready for clinical use? J Nucl Cardiol 2022; 29:506-514. [PMID: 32715418 DOI: 10.1007/s12350-020-02274-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Accepted: 06/14/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND The aim of this study was to investigate the feasibility of assessing absolute myocardial 99mTc-HMDP uptake in patients with suspected cardiac ATTR using SUV with a whole-body CZT SPECT-CT camera (DNM670CZT). METHODS Fifteen patients with suspected cardiac ATTR (Perugini ≥ 2) underwent a conventional 99mTc-HMDP planar imaging and a thoracic SPECT/CT using a DNM 670CZT. A control group consisted of 15 patients with negative scintigraphy (Perugini < 2). SUVmax (mg·L-1) and percentage of injected dose (%ID) were calculated in a cardiac volume of interest (VOI) encompassing the left ventricle. VOIs were also placed in the lung, the right pectoris major, and the sternum. A heart-to-lung SUVmax ratio (HLR) was calculated. RESULTS All ATTR patients demonstrated an increased cardiac HMDP SUVmax (12.2 ± 3.7 mg·L-1) vs controls (3.5 ± 1.2, P < .0001). Percentage of ID, pectoral uptake and HLR were significantly higher in the ATTR group (1.1 ± 0.3 vs 0.15 ± 0.8, P < .0001; 1.5 ± 0.3 vs 0.9 ± 0.3, P < .0001; 9.7 ± 3 vs 4.3 ± 2.2, P < .0001). Bone uptake was not statistically different between the two groups. CONCLUSION This study demonstrated the feasibility of quantitative 99mTc-HMDP SUVmax measurement using a whole-body SPECT/CT CZT camera in patients with suspected cardiac ATTR.
Collapse
Affiliation(s)
- Dimitri Bellevre
- Normandie Univ, UNICAEN, Signalisation, électrophysiologie et imagerie des lésions d'ischémie-reperfusion myocardique, FHU REMOD-VHF, Caen, France.
- Department of Nuclear Medicine, UF 5881, Groupement des Hôpitaux de l'Institut Catholique de Lille, Lomme, France.
- Department of Nuclear Medicine, IRIS, Hôpital Privé Le Bois, Lille, France.
| | - Alban Bailliez
- Department of Nuclear Medicine, UF 5881, Groupement des Hôpitaux de l'Institut Catholique de Lille, Lomme, France
- Department of Nuclear Medicine, IRIS, Hôpital Privé Le Bois, Lille, France
| | - François Delelis
- Department of Cardiology, Groupement des Hopitaux de l'instituts catholiques de Lille, Lomme, France
| | - Tanguy Blaire
- Department of Nuclear Medicine, UF 5881, Groupement des Hôpitaux de l'Institut Catholique de Lille, Lomme, France
- Department of Nuclear Medicine, IRIS, Hôpital Privé Le Bois, Lille, France
| | - Denis Agostini
- Normandie Univ, UNICAEN, Signalisation, électrophysiologie et imagerie des lésions d'ischémie-reperfusion myocardique, FHU REMOD-VHF, Caen, France
- Department of Nuclear Medicine, CHU Cote de Nacre, Normandy University, Caen, France
| | | | - Sylvestre Maréchaux
- Department of Cardiology, Groupement des Hopitaux de l'instituts catholiques de Lille, Lomme, France
| | - Alain Manrique
- Normandie Univ, UNICAEN, Signalisation, électrophysiologie et imagerie des lésions d'ischémie-reperfusion myocardique, FHU REMOD-VHF, Caen, France
- Department of Nuclear Medicine, CHU Cote de Nacre, Normandy University, Caen, France
| |
Collapse
|
8
|
Kalisvaart GM, van Velden FHP, Hernández-Girón I, Meijer KM, Ghesquiere-Dierickx LMH, Brink WM, Webb A, de Geus-Oei LF, Slump CH, Kuznetsov DV, Schaart DR, Grootjans W. Design and evaluation of a modular multimodality imaging phantom to simulate heterogeneous uptake and enhancement patterns for radiomic quantification in hybrid imaging; a feasibility study. Med Phys 2022; 49:3093-3106. [PMID: 35178781 PMCID: PMC9314050 DOI: 10.1002/mp.15537] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 01/31/2022] [Accepted: 02/02/2022] [Indexed: 11/21/2022] Open
Abstract
Background Accuracy and precision assessment in radiomic features is important for the determination of their potential to characterize cancer lesions. In this regard, simulation of different imaging conditions using specialized phantoms is increasingly being investigated. In this study, the design and evaluation of a modular multimodality imaging phantom to simulate heterogeneous uptake and enhancement patterns for radiomics quantification in hybrid imaging is presented. Methods A modular multimodality imaging phantom was constructed that could simulate different patterns of heterogeneous uptake and enhancement patterns in positron emission tomography (PET), single‐photon emission computed tomography (SPECT), computed tomography (CT), and magnetic resonance (MR) imaging. The phantom was designed to be used as an insert in the standard NEMA‐NU2 IEC body phantom casing. The entire phantom insert is composed of three segments, each containing three separately fillable compartments. The fillable compartments between segments had different sizes in order to simulate heterogeneous patterns at different spatial scales. The compartments were separately filled with different ratios of 99mTc‐pertechnetate, 18F‐fluorodeoxyglucose ([18F]FDG), iodine‐ and gadolinium‐based contrast agents for SPECT, PET, CT, and T1‐weighted MR imaging respectively. Image acquisition was performed using standard oncological protocols on all modalities and repeated five times for repeatability assessment. A total of 93 radiomic features were calculated. Variability was assessed by determining the coefficient of quartile variation (CQV) of the features. Comparison of feature repeatability at different modalities and spatial scales was performed using Kruskal‐Wallis‐, Mann‐Whitney U‐, one‐way ANOVA‐ and independent t‐tests. Results Heterogeneous uptake and enhancement could be simulated on all four imaging modalities. Radiomic features in SPECT were significantly less stable than in all other modalities. Features in PET were significantly less stable than in MR and CT. A total of 20 features, particularly in the gray‐level co‐occurrence matrix (GLCM) and gray‐level run‐length matrix (GLRLM) class, were found to be relatively stable in all four modalities for all three spatial scales of heterogeneous patterns (with CQV < 10%). Conclusion The phantom was suitable for simulating heterogeneous uptake and enhancement patterns in [18F]FDG‐PET, 99mTc‐SPECT, CT, and T1‐weighted MR images. The results of this work indicate that the phantom might be useful for the further development and optimization of imaging protocols for radiomic quantification in hybrid imaging modalities.
Collapse
Affiliation(s)
| | | | | | - Karin M Meijer
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Laura M H Ghesquiere-Dierickx
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.,Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Delft, The Netherlands.,Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Wyger M Brink
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew Webb
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Lioe-Fee de Geus-Oei
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.,Biomedical Photonic Imaging Group, University of Twente, Enschede, The Netherlands
| | - Cornelis H Slump
- Robotics and Mechatronics, University of Twente, Enschede, The Netherlands
| | - Dimitri V Kuznetsov
- Electronic and mechanical support division, Delft University of Technology, Delft, The Netherlands
| | - Dennis R Schaart
- Radiation Science and Technology, Delft University of Technology, Delft, The Netherlands.,Holland Proton Therapy Center (HollandPTC), Delft, The Netherlands
| | - Willem Grootjans
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
9
|
Piwowarska-Bilska H, Supińska A, Birkenfeld B. What validation tests can be done by the clinical medical physicist while waiting for the standardization of quantitative SPECT/CT imaging? EJNMMI Phys 2022; 9:8. [PMID: 35122533 PMCID: PMC8817961 DOI: 10.1186/s40658-022-00434-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 01/24/2022] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE The aim of the study was to assess the accuracy of quantitative SPECT/CT imaging in a clinical setting and to compare test results from two nuclear medicine departments. METHODS Phantom studies were carried out with two gamma cameras manufactured by GE Healthcare: Discovery NM/CT 670 and NM/CT 850, used in two nuclear medicine departments. The data were collected using a cylindrical uniform phantom and a NEMA/IEC NU2 Body Phantom, filled with 99mTc-pertechnetate. RESULTS The convergence of activity concentration recovery was validated for the two gamma cameras operating in two medical centers using the cylindrical uniform phantom. The comparison of results revealed a 5% difference in the background calibration factor Bg. cal; 6% difference in COV, and a 0.6% difference in total activity deviation ∆Atot. Recovery coefficients (RCmax) for activity concentration in spheres of the NEMA/IEC NU2 Body Phantom were measured for different image reconstruction techniques. RCmax was in the range of 0.2-0.4 for the smallest sphere (ϕ 10 mm), and 1.3-1.4 for the largest sphere (ϕ 37 mm). Conversion factors for SUVmax and SUVmean for the gamma camera systems used were 0.99 and 1.13, respectively. CONCLUSIONS (1) Measurements taken in our study confirmed the clinical suitability of 5 parameters of image quality (Bg. cal-background calibration factor, ∆Atot-total activity deviation, COV-coefficient of variation used for image noise assessment, QH-hot contrast, AM-accuracy of measurements, or RC-recovery coefficient) for the validation of SPECT/CT system performance in terms of correct quantitative acquisitions of images. (2) This work shows that absolute SPECT/CT quantification is achievable in clinical nuclear medicine centers. Results variation of quantitative analyses between centers is mainly related to the use of different reconstruction methods. (3) It is necessary to standardize the technique of measuring the SUV conversion factor obtained with different SPECT/CT scanners.
Collapse
Affiliation(s)
| | - Aleksandra Supińska
- Clinical Nuclear Medicine Department, University of Zielona Gora, Multi-Specialist Regional Hospital, Gorzow Wielkopolski, Poland
| | - Bożena Birkenfeld
- Nuclear Medicine Department, Pomeranian Medical University, Szczecin, Poland
| |
Collapse
|
10
|
Chiesa C, Sjogreen-Gleisner K, Walrand S, Strigari L, Flux G, Gear J, Stokke C, Gabina PM, Bernhardt P, Konijnenberg M. EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres. EJNMMI Phys 2021; 8:77. [PMID: 34767102 PMCID: PMC8589932 DOI: 10.1186/s40658-021-00394-3] [Citation(s) in RCA: 61] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 06/21/2021] [Indexed: 11/27/2022] Open
Abstract
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in 90Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of 99mTc albumin macro-aggregates (MAA) and 90Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between 99mTc-MAA predictions and actual 90Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments.Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected 99mTc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and 90Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected 99mTc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative 90Y bremsstrahlung SPECT can be used if dedicated correction methods are available.The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
Collapse
Affiliation(s)
- Carlo Chiesa
- Nuclear Medicine Unit, Foundation IRCCS Istituto Nazionale Tumori, Milan, Italy
| | | | - Stephan Walrand
- Nuclear Medicine, Molecular Imaging, Radiotherapy and Oncology Unit (MIRO), IECR, Université Catholique de Louvain, Brussels, Belgium
| | - Lidia Strigari
- Medical Physics Division, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Glenn Flux
- Joint Department of Physics, Royal Marsden Hospital & Institute of Cancer Research, Sutton, UK
| | - Jonathan Gear
- Joint Department of Physics, Royal Marsden Hospital & Institute of Cancer Research, Sutton, UK
| | - Caroline Stokke
- Department of Diagnostic Physics, Oslo University Hospital, Oslo, Norway
| | - Pablo Minguez Gabina
- Department of Medical Physics and Radiation Protection, Gurutzeta/Cruces University Hospital, Barakaldo, Spain
| | - Peter Bernhardt
- Department of Radiation Physics, Institute of Clinical Science, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Mark Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.
| |
Collapse
|
11
|
Zhang R, Wang M, Zhou Y, Wang S, Shen Y, Li N, Wang P, Tan J, Meng Z, Jia Q. Impacts of acquisition and reconstruction parameters on the absolute technetium quantification of the cadmium-zinc-telluride-based SPECT/CT system: a phantom study. EJNMMI Phys 2021; 8:66. [PMID: 34568990 PMCID: PMC8473509 DOI: 10.1186/s40658-021-00412-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 09/10/2021] [Indexed: 02/06/2023] Open
Abstract
Background The digital cadmium–zinc–telluride (CZT)-based SPECT system has many advantages, including better spatial and energy resolution. However, the impacts of different acquisition and reconstruction parameters on CZT SPECT quantification might still need to be validated. This study aimed to evaluate the impacts of acquisition parameters (the main energy window and acquisition time per frame) and reconstruction parameters (the number of iterations, subsets in iterative reconstruction, post-filter, and image correction methods) on the technetium quantification of CZT SPECT/CT. Methods A phantom (PET NEMA/IEC image quality, USA) was filled with four target-to-background (T/B) ratios (32:1, 16:1, 8:1, and 4:1) of technetium. Mean uptake values (the calculated mean concentrations for spheres) were measured to evaluate the recovery coefficient (RC) changes under different acquisition and reconstruction parameters. The corresponding standard deviations of mean uptake values were also measured to evaluate the quantification error. Image quality was evaluated using the National Electrical Manufacturers Association (NEMA) NU 2–2012 standard. Results For all T/B ratios, significant correlations were found between iterations and RCs (r = 0.62–0.96 for 1–35 iterations, r = 0.94–0.99 for 35–90 iterations) as well as between the full width at half maximum (FWHM) of the Gaussian filter and RCs (r = − 0.86 to − 1.00, all P values < 0.05). The regression coefficients of 1–35 iterations were higher than those of 35–90 iterations (0.51–1.60 vs. 0.02–0.19). RCs calculated with AC (attenuation correction) + SC (scatter correction) + RR (resolution recovery correction) combination were more accurate (53.82–106.70%) than those calculated with other combinations (all P values < 0.05). No significant statistical differences (all P values > 0.05) were found between the 15% and 20% energy windows except for the 32:1 T/B ratio (P value = 0.023) or between the 10 s/frame and 120 s/frame acquisition times except for the 4:1 T/B ratio (P value = 0.015) in terms of RCs. Conclusions CZT-SPECT/CT of technetium resulted in good quantification accuracy. The favourable acquisition parameters might be a 15% energy window and 40 s/frame of acquisition time. The favourable reconstruction parameters might be 35 iterations, 20 subsets, the AC + SC + RR correction combination, and no filter. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00412-4.
Collapse
Affiliation(s)
- Ruyi Zhang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Miao Wang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Yaqian Zhou
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Shen Wang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Yiming Shen
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Ning Li
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Peng Wang
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Jian Tan
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China
| | - Zhaowei Meng
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
| | - Qiang Jia
- Department of Nuclear Medicine, Tianjin Medical University General Hospital, Anshan Road No. 154, Heping District, Tianjin, 300052, People's Republic of China.
| |
Collapse
|
12
|
Kupitz D, Wissel H, Wuestemann J, Bluemel S, Pech M, Amthauer H, Kreissl MC, Grosser OS. Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT. EJNMMI Phys 2021; 8:57. [PMID: 34328565 PMCID: PMC8324619 DOI: 10.1186/s40658-021-00405-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 07/13/2021] [Indexed: 11/29/2022] Open
Abstract
Background The introduction of hybrid SPECT/CT devices enables quantitative imaging in SPECT, providing a methodological setup for quantitation using SPECT tracers comparable to PET/CT. We evaluated a specific quantitative reconstruction algorithm for SPECT data using a 99mTc-filled NEMA phantom. Quantitative and qualitative image parameters were evaluated for different parametrizations of the acquisition and reconstruction protocol to identify an optimized quantitative protocol. Results The reconstructed activity concentration (ACrec) and the signal-to-noise ratio (SNR) of all examined protocols (n = 16) were significantly affected by the parametrization of the weighting factor k used in scatter correction, the total number of iterations and the sphere volume (all, p < 0.0001). The two examined SPECT acquisition protocols (with 60 or 120 projections) had a minor impact on the ACrec and no significant impact on the SNR. In comparison to the known AC, the use of default scatter correction (k = 0.47) or object-specific scatter correction (k = 0.18) resulted in an underestimation of ACrec in the largest sphere volume (26.5 ml) by − 13.9 kBq/ml (− 16.3%) and − 7.1 kBq/ml (− 8.4%), respectively. An increase in total iterations leads to an increase in estimated AC and a decrease in SNR. The mean difference between ACrec and known AC decreased with an increasing number of total iterations (e.g., for 20 iterations (2 iterations/10 subsets) = − 14.6 kBq/ml (− 17.1%), 240 iterations (24i/10s) = − 8.0 kBq/ml (− 9.4%), p < 0.0001). In parallel, the mean SNR decreased significantly from 2i/10s to 24i/10s by 76% (p < 0.0001). Conclusion Quantitative SPECT imaging is feasible with the used reconstruction algorithm and hybrid SPECT/CT, and its consistent implementation in diagnostics may provide perspectives for quantification in routine clinical practice (e.g., assessment of bone metabolism). When combining quantitative analysis and diagnostic imaging, we recommend using two different reconstruction protocols with task-specific optimized setups (quantitative vs. qualitative reconstruction). Furthermore, individual scatter correction significantly improves both quantitative and qualitative results. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00405-3.
Collapse
Affiliation(s)
- Dennis Kupitz
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
| | - Heiko Wissel
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany
| | - Jan Wuestemann
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany
| | - Stephanie Bluemel
- Department of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Maciej Pech
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.,Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany
| | - Holger Amthauer
- Department of Nuclear Medicine, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Michael C Kreissl
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.,Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany
| | - Oliver S Grosser
- Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.,Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
13
|
Preparation and Evaluation of Novel Folate Isonitrile 99mTc Complexes as Potential Tumor Imaging Agents to Target Folate Receptors. Molecules 2021; 26:molecules26154552. [PMID: 34361705 PMCID: PMC8348780 DOI: 10.3390/molecules26154552] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 07/17/2021] [Accepted: 07/26/2021] [Indexed: 11/17/2022] Open
Abstract
In order to seek novel technetium-99m folate receptor-targeting agents, two folate derivatives (CN5FA and CNPFA) were synthesized and radiolabeled to obtain [99mTc]Tc-CN5FA and [99mTc]Tc-CNPFA complexes, which exhibited high radiochemical purity (>95%) without purification, hydrophilicity, and good stability in vitro. The KB cell competitive binding experiments indicated that [99mTc]Tc-CN5FA and [99mTc]Tc-CNPFA had specificity to folate receptor. Biodistribution studies in KB tumor-bearing mice illustrated that [99mTc]Tc-CN5FA and [99mTc]Tc-CNPFA had specific tumor uptake. Compared with [99mTc]Tc-CN5FA, the tumor/muscle ratios of [99mTc]Tc-CNPFA were higher, resulting in a better SPECT/CT imaging background. According to the results, the two 99mTc complexes have potential as tumor imaging agents to target folate receptors.
Collapse
|
14
|
van de Burgt A, Dibbets-Schneider P, Slump CH, Scholte AJHA, Atsma DE, de Geus-Oei LF, van Velden FHP. Experimental validation of absolute SPECT/CT quantification for response monitoring in patients with coronary artery disease. EJNMMI Phys 2021; 8:48. [PMID: 34132918 PMCID: PMC8208344 DOI: 10.1186/s40658-021-00393-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 06/08/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Quantitative SPECT enables absolute quantification of uptake in perfusion defects. The aim of this experimental study is to assess quantitative accuracy and precision of a novel iterative reconstruction technique (Evolution; GE Healthcare) for the potential application of response monitoring using 99mTc-tetrofosmin SPECT/CT in patients with coronary artery disease (CAD). METHODS Acquisitions of an anthropomorphic torso phantom with cardiac insert containing defects (with varying sizes), filled with 99mTc-pertechnetate, were performed on a SPECT/CT (Discovery 670 Pro, GE Healthcare). Subsequently, volumes of interest of the defects were manually drawn on CT to assess the recovery coefficient (RC). Bull's eye plots were composed to evaluate the uptake per segment. Finally, 99mTc-tetrofosmin SPECT/CT scans of 10 CAD patients were used to illustrate clinical application. RESULTS The phantom study indicated that Evolution showed convergence after 7 iterations and 10 subsets. The average repeatability deviation of all configurations was 2.91% and 3.15% (%SD mean) for filtered (Butterworth) and unfiltered data, respectively. The accuracy after post-filtering was lower compared to the unfiltered data with a mean (SD) RC of 0.63 (0.05) and 0.70 (0.07), respectively (p < 0.05). More artificial defects were found on Bull's eye plots created with the unfiltered data compared to filtered data. Eight out of ten patients showed significant changes in uptake before and after treatment (p < 0.05). CONCLUSION Quantification of 99mTc-tetrofosmin SPECT/CT seems feasible for CAD patients when 7 iterations (10 subsets), Butterworth post-filtering (cut off frequency 0.52 in cycles/cm, order of 5) and manual CT-delineation are applied. However, future prospective patient studies are required for clinical application.
Collapse
Affiliation(s)
- Alina van de Burgt
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.
| | - Petra Dibbets-Schneider
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands
| | - Cornelis H Slump
- Technical Medical Center, University of Twente, Enschede, The Netherlands
| | - Arthur J H A Scholte
- Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Douwe E Atsma
- Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Lioe-Fee de Geus-Oei
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands.,Biomedical Photonic Imaging Group, University of Twente, Enschede, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, PO Box 9600, 2300 RC, Leiden, The Netherlands
| |
Collapse
|
15
|
Völter F, Mittlmeier L, Gosewisch A, Brosch-Lenz J, Gildehaus FJ, Zacherl MJ, Beyer L, Stief CG, Holzgreve A, Rübenthaler J, Cyran CC, Böning G, Bartenstein P, Todica A, Ilhan H. Correlation of an Index-Lesion-Based SPECT Dosimetry Method with Mean Tumor Dose and Clinical Outcome after 177Lu-PSMA-617 Radioligand Therapy. Diagnostics (Basel) 2021; 11:diagnostics11030428. [PMID: 33802417 PMCID: PMC7999994 DOI: 10.3390/diagnostics11030428] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 02/18/2021] [Accepted: 02/25/2021] [Indexed: 12/31/2022] Open
Abstract
Background: Dosimetry can tailor prostate-specific membrane-antigen-targeted radioligand therapy (PSMA-RLT) for metastatic castration-resistant prostate cancer (mCRPC). However, whole-body tumor dosimetry is challenging in patients with a high tumor burden. We evaluate a simplified index-lesion-based single-photon emission computed tomography (SPECT) dosimetry method in correlation with clinical outcome. Methods: 30 mCRPC patients were included (median 71 years). The dosimetry was performed for the first cycle using quantitative 177Lu-SPECT. The response was evaluated using RECIST 1.1 and PERCIST criteria, as well as changes in PSMA-positive tumor volume (PSMA-TV) in post-therapy PSMA-PET and biochemical response according to PSA changes after two RLT cycles. Results: Mean tumor doses as well as index-lesion doses were significantly higher in PERCIST responders compared to non-responders (10.2 ± 12.0 Gy/GBq vs. 4.0 ± 2.9 Gy/GBq, p = 0.03 and 13.7 ± 14.2 Gy/GBq vs. 5.9 ± 4.4 Gy/GBq, p = 0.04, respectively). No significant differences in mean tumor and index lesion doses were observed between responders and non-responders according to RECIST 1.1, PSMA-TV, and biochemical response criteria. Conclusion: Compared to mean tumor doses on a patient level, single index-lesion-based SPECT dosimetry correlates equally well with the response to PSMA-RLT according to PERCIST criteria and may represent a fast and feasible dosimetry approach for clinical routine.
Collapse
Affiliation(s)
- Friederike Völter
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Lena Mittlmeier
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Astrid Gosewisch
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Julia Brosch-Lenz
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Franz Josef Gildehaus
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Mathias Johannes Zacherl
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Leonie Beyer
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Christian G. Stief
- Department of Urology, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany;
| | - Adrien Holzgreve
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Johannes Rübenthaler
- Department of Radiology, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (J.R.); (C.C.C.)
| | - Clemens C. Cyran
- Department of Radiology, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (J.R.); (C.C.C.)
| | - Guido Böning
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Peter Bartenstein
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Andrei Todica
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
| | - Harun Ilhan
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, 80331 Munich, Germany; (F.V.); (L.M.); (A.G.); (J.B.-L.); (F.J.G.); (M.J.Z.); (L.B.); (A.H.); (G.B.); (P.B.); (A.T.)
- Correspondence: ; Tel.: +49-89-4400-77655
| |
Collapse
|
16
|
Gan Q, Zhang X, Ruan Q, Fang S, Zhang J. 99mTc-CN7DG: A Highly Expected SPECT Imaging Agent of Cancer with Satisfactory Tumor Uptake and Tumor-to-Nontarget Ratios. Mol Pharm 2021; 18:1356-1363. [PMID: 33586982 DOI: 10.1021/acs.molpharmaceut.0c01177] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
A novel glucose derivative (CN7DG) possessing an isonitrile as a coordinating group was synthesized, and 99mTc-CN7DG, which was expected to be a powerful tumor imaging agent for SPECT, was prepared in a kit by the reaction of CN7DG with SnCl2·2H2O and 99mTcO4-. 99mTc-CN7DG exhibited good stability and was transported via glucose transporters. Biodistribution results in mice bearing A549 tumor models showed that 99mTc-CN7DG had a higher uptake at the tumor sites and better tumor/blood and tumor/muscle ratios than did [18F]FDG and 99mTc-CN5DG. SPECT/CT imaging studies showed obvious accumulation in tumor sites, suggesting that 99mTc-CN7DG is a promising candidate for tumor imaging. Because 99mTc and 188Re stand for a "theranostic pair", 188Re-CN7DG is expected to be prepared as a promising agent for tumor therapy.
Collapse
Affiliation(s)
- Qianqian Gan
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, People's Republic of China
| | - Xuran Zhang
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, People's Republic of China
| | - Qing Ruan
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, People's Republic of China
| | - Si'an Fang
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, People's Republic of China
| | - Junbo Zhang
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, People's Republic of China
| |
Collapse
|
17
|
Weissinger M, Vogel J, Kupferschläger J, Dittmann H, Castaneda Vega SG, Grosse U, Artzner C, Nikolaou K, la Fougere C, Grözinger G. Correlation of C-arm CT acquired parenchymal blood volume (PBV) with 99mTc-macroaggregated albumin (MAA) SPECT/CT for radioembolization work-up. PLoS One 2020; 15:e0244235. [PMID: 33378338 PMCID: PMC7773241 DOI: 10.1371/journal.pone.0244235] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 12/05/2020] [Indexed: 01/22/2023] Open
Abstract
OBJECTIVE SPECT/CT with 99mTc-macroaggregated albumin (MAA) is generally used for diagnostic work-up prior to transarterial radioembolization (TARE) to exclude shunts and to provide additional information for treatment stratification and dose calculation. C-arm CT is used for determination of lobular vascular supply and assessment of parenchymal blood volume (PBV). Aim of this study was to correlate MAA-uptake and PBV-maps in hepatocellular carcinoma (HCC) and hepatic metastases of the colorectal carcinoma (CRC). MATERIALS AND METHODS 34 patients underwent a PBV C-arm CT immediately followed by 99mTc-MAA injection and a SPECT/CT acquisition after 1 h uptake. MAA-uptake and PBV-maps were visually assessed and semi-quantitatively analyzed (MAA-tumor/liver-parenchyma = MAA-TBR or PBV in ml/100ml). In case of a poor match, tumors were additionally correlated with post-TARE 90Y-Bremsstrahlung-SPECT/CT as a reference. RESULTS 102 HCC or CRC metastases were analyzed. HCC presented with significantly higher MAA-TBR (7.6 vs. 3.9, p<0.05) compared to CRC. Tumors showed strong intra- and inter-individual dissimilarities between TBR and PBV with a weak correlations for capsular HCCs (r = 0.45, p<0.05) and no correlation for CRC. The demarcation of lesions was slightly better for both HCC and CRC in PBV-maps compared to MAA-SPECT/CT (exact match: 52%/50%; same intensity/homogeneity: 38%/39%; insufficient 10%/11%). MAA-SPECT/CT revealed a better visual correlation with post-therapeutic 90Y-Bremsstrahlung-SPECT/CT. CONCLUSION The acquisition of PBV can improve the detectability of small intrahepatic tumors and correlates with the MAA-Uptake in HCC. The results indicate that 99mTc-MAA-SPECT/CT remains to be the superior method for the prediction of post-therapeutic 90Y-particle distribution, especially in CRC. However, intra-procedural PBV acquisition has the potential to become an additional factor for TARE planning, in addition to improving the determination of segment and tumor blood supply, which has been demonstrated previously.
Collapse
Affiliation(s)
- Matthias Weissinger
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Jonas Vogel
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Jürgen Kupferschläger
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Helmut Dittmann
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Salvador Guillermo Castaneda Vega
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
- Department for Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, University Hospital Tuebingen, Tuebingen, Germany
| | - Ulrich Grosse
- Department of Diagnostic and Interventional Radiology, Kantonsspital Frauenfeld, Frauenfeld, Switzerland
| | - Christoph Artzner
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
- iFIT-Cluster of Excellence, Eberhard Karls University Tuebingen, Tuebingen, Germany
- German Cancer Consortium (DKTK), Partner Site Tuebingen, Tuebingen, Germany
| | - Christian la Fougere
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
- iFIT-Cluster of Excellence, Eberhard Karls University Tuebingen, Tuebingen, Germany
- German Cancer Consortium (DKTK), Partner Site Tuebingen, Tuebingen, Germany
- * E-mail:
| | - Gerd Grözinger
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| |
Collapse
|
18
|
Hanaoka K, Miyaji N, Yoneyama H, Ogawa M, Maeda T, Sakaguchi K, Iimori T, Tsushima H. [Radiological Technology for Targeted Radionuclide Therapy]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2020; 76:1237-1247. [PMID: 33342942 DOI: 10.6009/jjrt.2020_jsrt_76.12.1237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Targeted radioisotope therapy (TRT) is a radiotherapy using radioisotope or drug incorporating it and has been used as a treatment for selectively irradiating cancer cells. In recent years, interest in TRT has increased due to improvements in radionuclide production technology, development of new drugs and imaging modalities, and improvements in radiation technology. In order to enhance the effect of TRT, measurement of individual radiation doses to tumor tissue and organs at risk is important using highly quantitative nuclear medicine images. In this paper, we present a review of literature on optimization of TRT, which is a new research area from the perspective of radiation technology.
Collapse
Affiliation(s)
- Kohei Hanaoka
- Institute of Advanced Clinical Medicine, Kindai University
| | - Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| | - Hiroto Yoneyama
- Department of Radiological Technology, Kanazawa University Hospital
| | | | - Takamasa Maeda
- Radiological Technology Section, QST Hospital, National Institutes for Quantum and Radiological Science and Technology
| | | | | | - Hiroyuki Tsushima
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences
| |
Collapse
|
19
|
Rohani MFM, Yonan SNM, Tagiling N, Zainon WMNW, Udin Y, Nawi NM. Standardized Uptake Value from Semiquantitative Bone Single-Photon Emission Computed Tomography/Computed Tomography in Normal Thoracic and Lumbar Vertebrae of Breast Cancer Patients. Asian Spine J 2020; 14:629-638. [PMID: 32213791 PMCID: PMC7595810 DOI: 10.31616/asj.2019.0308] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 10/29/2019] [Accepted: 11/04/2019] [Indexed: 11/28/2022] Open
Abstract
STUDY DESIGN Retrospective study. PURPOSE This study aims to semiquantitatively evaluate the standardized uptake value (SUV) of 99mTc-methylene diphosphonate (MDP) radionuclide tracer in the normal vertebrae of breast cancer patients using an integrated single-photon emission computed tomography (SPECT)/computed tomography (CT) scanner. OVERVIEW OF LITERATURE Molecular imaging techniques using gamma cameras and stand-alone SPECT have traditionally been utilized to evaluate metastatic bone diseases. However, these methods lack quantitative analysis capabilities, impeding accurate uptake characterization. METHODS A total of 30 randomly selected female breast cancer patients were enrolled in this study. The SUV mean (SUVmean) and SUV maximum (SUVmax) values for 286 normal vertebrae at the thoracic and lumbar levels were calculated based on the patients' body weight (BW), body surface area (BSA), and lean body mass (LBM). Additionally, 106 degenerative joint disease (DJD) lesions of the spine were also characterized, and both their BW SUVmean and SUVmax values were obtained. A receiver operating characteristic (ROC) curve analysis was then performed to determine the cutoff value of SUV for differentiating DJD from normal vertebrae. RESULTS The mean±standard deviations for the SUVmean and SUVmax in the normal vertebrae displayed a relatively wide variability: 3.92±0.27 and 6.51±0.72 for BW, 1.05±0.07 and 1.75±0.17 for BSA, and 2.70±0.19 and 4.50±0.44 for LBM, respectively. Generally, the SUVmean had a lower coefficient of variation than the SUVmax. For DJD, the mean±standard deviation for the BW SUVmean and SUVmax was 5.26±3.24 and 7.50±4.34, respectively. Based on the ROC curve, no optimal cutoff value was found to differentiate DJD from normal vertebrae. CONCLUSIONS In this study, the SUV of 99mTc-MDP was successfully determined using SPECT/CT. This research provides an approach that could potentially aid in the clinical quantification of radionuclide uptake in normal vertebrae for the management of breast cancer patients.
Collapse
Affiliation(s)
- Mohd Fazrin Mohd Rohani
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
- Hospital Universiti Sains Malaysia, Kubang Kerian, Malaysia
| | - Siti Nurshahirah Mohd Yonan
- Medical Radiation Program, School of Health Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
| | - Nashrulhaq Tagiling
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
| | | | - Yusri Udin
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
| | - Norazlina Mat Nawi
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
- Hospital Universiti Sains Malaysia, Kubang Kerian, Malaysia
| |
Collapse
|
20
|
Peters SMB, Meyer Viol SL, van der Werf NR, de Jong N, van Velden FHP, Meeuwis A, Konijnenberg MW, Gotthardt M, de Jong HWAM, Segbers M. Variability in lutetium-177 SPECT quantification between different state-of-the-art SPECT/CT systems. EJNMMI Phys 2020; 7:9. [PMID: 32048097 PMCID: PMC7013023 DOI: 10.1186/s40658-020-0278-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 01/27/2020] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Quantitative SPECT imaging in targeted radionuclide therapy with lutetium-177 holds great potential for individualized treatment based on dose assessment. The establishment of dose-effect relations requires a standardized method for SPECT quantification. The purpose of this multi-center study is to evaluate quantitative accuracy and inter-system variations of different SPECT/CT systems with corresponding commercially available quantitative reconstruction algorithms. This is an important step towards a vendor-independent standard for quantitative lutetium-177 SPECT. METHODS Four state-of-the-art SPECT/CT systems were included: Discovery™ NM/CT 670Pro (GE Healthcare), Symbia Intevo™, and two Symbia™ T16 (Siemens Healthineers). Quantitative accuracy and inter-system variations were evaluated by repeatedly scanning a cylindrical phantom with 6 spherical inserts (0.5 - 113 ml). A sphere-to-background activity concentration ratio of 10:1 was used. Acquisition settings were standardized: medium energy collimator, body contour trajectory, photon energy window of 208 keV (± 10%), adjacent 20% lower scatter window, 2 × 64 projections, 128 × 128 matrix size, and 40 s projection time. Reconstructions were performed using GE Evolution with Q.Metrix™, Siemens xSPECT Quant™, Siemens Broad Quantification™ or Siemens Flash3D™ algorithms using vendor recommended settings. In addition, projection data were reconstructed using Hermes SUV SPECT™ with standardized reconstruction settings to obtain a vendor-neutral quantitative reconstruction for all systems. Volumes of interest (VOI) for the spheres were obtained by applying a 50% threshold of the sphere maximum voxel value corrected for background activity. For each sphere, the mean and maximum recovery coefficient (RCmean and RCmax) of three repeated measurements was calculated, defined as the imaged activity concentration divided by the actual activity concentration. Inter-system variations were defined as the range of RC over all systems. RESULTS RC decreased with decreasing sphere volume. Inter-system variations with vendor-specific reconstructions were between 0.06 and 0.41 for RCmean depending on sphere size (maximum 118% quantification difference), and improved to 0.02-0.19 with vendor-neutral reconstructions (maximum 38% quantification difference). CONCLUSION This study shows that eliminating sources of possible variation drastically reduces inter-system variation in quantification. This means that absolute SPECT quantification for 177Lu is feasible in a multi-center and multi-vendor setting; however, close agreement between vendors and sites is key for multi-center dosimetry and quantitative biomarker studies.
Collapse
Affiliation(s)
- Steffie M B Peters
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands.
| | - Sebastiaan L Meyer Viol
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Niels R van der Werf
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Nick de Jong
- Department of Radiology, Section of Medical Technology, Leiden University Medical Center, Leiden, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Medical Technology, Leiden University Medical Center, Leiden, The Netherlands
| | - Antoi Meeuwis
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands
| | - Mark W Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Martin Gotthardt
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
21
|
Peters SMB, van der Werf NR, Segbers M, van Velden FHP, Wierts R, Blokland KJAK, Konijnenberg MW, Lazarenko SV, Visser EP, Gotthardt M. Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study. EJNMMI Phys 2019; 6:29. [PMID: 31879813 PMCID: PMC6933042 DOI: 10.1186/s40658-019-0268-5] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 12/05/2019] [Indexed: 11/29/2022] Open
Abstract
Abstract Absolute quantification of radiotracer distribution using SPECT/CT imaging is of great importance for dosimetry aimed at personalized radionuclide precision treatment. However, its accuracy depends on many factors. Using phantom measurements, this multi-vendor and multi-center study evaluates the quantitative accuracy and inter-system variability of various SPECT/CT systems as well as the effect of patient size, processing software and reconstruction algorithms on recovery coefficients (RC). Methods Five SPECT/CT systems were included: Discovery™ NM/CT 670 Pro (GE Healthcare), Precedence™ 6 (Philips Healthcare), Symbia Intevo™, and Symbia™ T16 (twice) (Siemens Healthineers). Three phantoms were used based on the NEMA IEC body phantom without lung insert simulating body mass indexes (BMI) of 25, 28, and 47 kg/m2. Six spheres (0.5–26.5 mL) and background were filled with 0.1 and 0.01 MBq/mL 99mTc-pertechnetate, respectively. Volumes of interest (VOI) of spheres were obtained by a region growing technique using a 50% threshold of the maximum voxel value corrected for background activity. RC, defined as imaged activity concentration divided by actual activity concentration, were determined for maximum (RCmax) and mean voxel value (RCmean) in the VOI for each sphere diameter. Inter-system variability was expressed as median absolute deviation (MAD) of RC. Acquisition settings were standardized. Images were reconstructed using vendor-specific 3D iterative reconstruction algorithms with institute-specific settings used in clinical practice and processed using a standardized, in-house developed processing tool based on the SimpleITK framework. Additionally, all data were reconstructed with a vendor-neutral reconstruction algorithm (Hybrid Recon™; Hermes Medical Solutions). Results RC decreased with decreasing sphere diameter for each system. Inter-system variability (MAD) was 16 and 17% for RCmean and RCmax, respectively. Standardized reconstruction decreased this variability to 4 and 5%. High BMI hampers quantification of small lesions (< 10 ml). Conclusion Absolute SPECT quantification in a multi-center and multi-vendor setting is feasible, especially when reconstruction protocols are standardized, paving the way for a standard for absolute quantitative SPECT.
Collapse
Affiliation(s)
- Steffie M B Peters
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
| | - Niels R van der Werf
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.,Department of Medical Physics, Albert Schweitzer Hospital, Dordrecht, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Medical Physics, Leiden University Medical Center, Leiden, The Netherlands
| | - Roel Wierts
- Department of Radiology and Nuclear Medicine, Maastricht UMC+, Maastricht, The Netherlands
| | - Koos J A K Blokland
- Department of Radiology, Section of Medical Physics, Leiden University Medical Center, Leiden, The Netherlands
| | - Mark W Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Sergiy V Lazarenko
- Department of Nuclear Medicine, Noordwest Ziekenhuisgroep, Alkmaar, The Netherlands
| | - Eric P Visser
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Martin Gotthardt
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| |
Collapse
|
22
|
Scimeca M, Urbano N, Bonfiglio R, Duggento A, Toschi N, Schillaci O, Bonanno E. Novel insights into breast cancer progression and metastasis: A multidisciplinary opportunity to transition from biology to clinical oncology. Biochim Biophys Acta Rev Cancer 2019; 1872:138-148. [PMID: 31348975 DOI: 10.1016/j.bbcan.2019.07.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 06/25/2019] [Accepted: 07/15/2019] [Indexed: 12/11/2022]
Abstract
According to the most recent epidemiological studies, breast cancer shows the highest incidence and the second leading cause of death in women. Cancer progression and metastasis are the main events related to poor survival of breast cancer patients. This can be explained by the presence of highly resistant to chemo- and radiotherapy stem cells in many breast tumor tissues. In this context, numerous studies highlighted the possible involvement of epithelial to mesenchymal transition phenomenon as biological program to generate cancer stem cells, and thus participate to both metastatic and drug resistance process. Therefore, the comprehension of mechanisms (both cellular and molecular) involved in breast cancer occurrence and progression can lay the foundation for the development of new diagnostic and therapeutical protocols. In this review, we reported the most important findings in the field of breast cancer highlighting the most recent data concerning breast tumor biology, diagnosis and therapy.
Collapse
Affiliation(s)
- Manuel Scimeca
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier 1, Rome 00133, Italy; San Raffaele University, Via di Val Cannuta 247, 00166 Rome, Italy; Fondazione Umberto Veronesi (FUV), Piazza Velasca 5, 20122 Milano (Mi), Italy.
| | | | - Rita Bonfiglio
- Department of Experimental Medicine, University "Tor Vergata", Via Montpellier 1, Rome 00133, Italy
| | - Andrea Duggento
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier 1, Rome 00133, Italy
| | - Nicola Toschi
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier 1, Rome 00133, Italy; Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging and Harvard Medical School, Massachusetts General Hospital, Boston, MA, United States
| | - Orazio Schillaci
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier 1, Rome 00133, Italy; IRCCS Neuromed, Pozzilli, Italy
| | - Elena Bonanno
- Department of Experimental Medicine, University "Tor Vergata", Via Montpellier 1, Rome 00133, Italy; Neuromed Group, "Diagnostica Medica" and "Villa dei Platani", Avellino, Italy
| |