Dunn A, Wagner S, Sussman D. Scoping review of magnetic resonance motion imaging phantoms. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01164-9. [PMID: 38739218 DOI: 10.1007/s10334-024-01164-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 03/28/2024] [Accepted: 04/29/2024] [Indexed: 05/14/2024]
Abstract
To review and analyze the currently available MRI motion phantoms. Publications were collected from the Toronto Metropolitan University Library, PubMed, and IEEE Xplore. Phantoms were categorized based on the motions they generated: linear/cartesian, cardiac-dilative, lung-dilative, rotational, deformation or rolling. Metrics were extracted from each publication to assess the motion mechanisms, construction methods, as well as phantom validation. A total of 60 publications were reviewed, identifying 48 unique motion phantoms. Translational movement was the most common movement (used in 38% of phantoms), followed by cardiac-dilative (27%) movement and rotational movement (23%). The average degrees of freedom for all phantoms were determined to be 1.42. Motion phantom publications lack quantification of their impact on signal-to-noise ratio through standardized testing. At present, there is a lack of phantoms that are designed for multi-role as many currently have few degrees of freedom.
Collapse
Affiliation(s)
- Alexander Dunn
- Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST) at Toronto Metropolitan University and St. Michael's Hospital, Toronto, Canada
| | - Sophie Wagner
- Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST) at Toronto Metropolitan University and St. Michael's Hospital, Toronto, Canada
| | - Dafna Sussman
- Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada.
- Institute for Biomedical Engineering, Science and Technology (iBEST) at Toronto Metropolitan University and St. Michael's Hospital, Toronto, Canada.
- Department of Obstetrics and Gynecology, University of Toronto, Toronto, Canada.
| |
Collapse
|
2
|
Oglesby RT, Lam WW, Stanisz GJ. A strategy to prevent a temperature-induced MRI artifact in warm liquid phantoms due to convection currents. NMR IN BIOMEDICINE 2021; 34:e4494. [PMID: 33586271 DOI: 10.1002/nbm.4494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 01/16/2021] [Accepted: 02/02/2021] [Indexed: 06/12/2023]
Abstract
MRI phantom studies often fail to mimic the temperature of the human body, which can negatively impact accuracy. An artifact induced by increasing temperature in liquid phantoms was observed, presenting a significant challenge to temperature-controlled experiments. In this study we characterize and provide a solution to eliminate this temperature-induced MRI artifact. Low concentration (0.5-2.5 mM) agar phantoms were prepared. Utilizing a temperature-controlled phantom holder, T1 - and T2 -weighted structural images were acquired at 7 T along with quantitative B0 , B1 , T1 , T2 and ADC maps at both 25 and 37°C. Additionally, computer simulations were conducted to demonstrate the fluid flow and thermal flux patterns in water to provide an insight into the origins of the artifact. Evidence from computer simulation and quantitative MRI strongly suggest the artifact was caused by heat transfer in the form of natural convection leading to structured patterns of signal loss in MR images. The artifact was present up to agar concentrations of 1.5 mM (T1 = 3068 ± 16 ms, T2 = 1052 ± 20 ms, ADC = 2.29 ± 0.36 × 10-3 mm2 /s at 25°C; T1 = 3928 ± 44 ms, T2 = 1122 ± 24 ms, ADC = 2.64 ± 0.49 × 10-3 mm2 /s at 37°C), above which point increased sample viscosity no longer allows for convection currents, thereby eliminating the artifact. The methodology described in this work simplifies quantitative MR acquisition of liquid phantoms at physiological temperature by suppressing convection currents with relatively small changes to intrinsic MR parameters (T1 increased by 1.4% and T2 decreased by 17% for 1.5 mM agar at 25°C).
Collapse
Affiliation(s)
- Ryan T Oglesby
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
- Medical Biophysics, University of Toronto, Toronto, ON, Canada
| | - Wilfred W Lam
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Greg J Stanisz
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
- Medical Biophysics, University of Toronto, Toronto, ON, Canada
- Neurosurgery and Paediatric Neurosurgery, Medical University of Lublin, Lublin, Poland
| |
Collapse
|
3
|
Kurz C, Buizza G, Landry G, Kamp F, Rabe M, Paganelli C, Baroni G, Reiner M, Keall PJ, van den Berg CAT, Riboldi M. Medical physics challenges in clinical MR-guided radiotherapy. Radiat Oncol 2020; 15:93. [PMID: 32370788 PMCID: PMC7201982 DOI: 10.1186/s13014-020-01524-4] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Accepted: 03/24/2020] [Indexed: 12/18/2022] Open
Abstract
The integration of magnetic resonance imaging (MRI) for guidance in external beam radiotherapy has faced significant research and development efforts in recent years. The current availability of linear accelerators with an embedded MRI unit, providing volumetric imaging at excellent soft tissue contrast, is expected to provide novel possibilities in the implementation of image-guided adaptive radiotherapy (IGART) protocols. This study reviews open medical physics issues in MR-guided radiotherapy (MRgRT) implementation, with a focus on current approaches and on the potential for innovation in IGART.Daily imaging in MRgRT provides the ability to visualize the static anatomy, to capture internal tumor motion and to extract quantitative image features for treatment verification and monitoring. Those capabilities enable the use of treatment adaptation, with potential benefits in terms of personalized medicine. The use of online MRI requires dedicated efforts to perform accurate dose measurements and calculations, due to the presence of magnetic fields. Likewise, MRgRT requires dedicated quality assurance (QA) protocols for safe clinical implementation.Reaction to anatomical changes in MRgRT, as visualized on daily images, demands for treatment adaptation concepts, with stringent requirements in terms of fast and accurate validation before the treatment fraction can be delivered. This entails specific challenges in terms of treatment workflow optimization, QA, and verification of the expected delivered dose while the patient is in treatment position. Those challenges require specialized medical physics developments towards the aim of fully exploiting MRI capabilities. Conversely, the use of MRgRT allows for higher confidence in tumor targeting and organs-at-risk (OAR) sparing.The systematic use of MRgRT brings the possibility of leveraging IGART methods for the optimization of tumor targeting and quantitative treatment verification. Although several challenges exist, the intrinsic benefits of MRgRT will provide a deeper understanding of dose delivery effects on an individual basis, with the potential for further treatment personalization.
Collapse
Affiliation(s)
- Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany
- Department of Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748, Garching, Germany
| | - Giulia Buizza
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, P.za Leonardo da Vinci 32, 20133, Milano, Italy
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany
- Department of Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748, Garching, Germany
- German Cancer Consortium (DKTK), 81377, Munich, Germany
| | - Florian Kamp
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany
| | - Moritz Rabe
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, P.za Leonardo da Vinci 32, 20133, Milano, Italy
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, P.za Leonardo da Vinci 32, 20133, Milano, Italy
- Bioengineering Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Privata Campeggi 53, 27100, Pavia, Italy
| | - Michael Reiner
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377, Munich, Germany
| | - Paul J Keall
- ACRF Image X Institute, University of Sydney, Sydney, NSW, 2006, Australia
| | - Cornelis A T van den Berg
- Department of Radiotherapy, University Medical Centre Utrecht, PO box 85500, 3508 GA, Utrecht, The Netherlands
| | - Marco Riboldi
- Department of Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748, Garching, Germany.
| |
Collapse
|
4
|
Colvill E, Krieger M, Bosshard P, Steinacher P, Rohrer Schnidrig BA, Parkel T, Stergiou I, Zhang Y, Peroni M, Safai S, Weber DC, Lomax A, Fattori G. Anthropomorphic phantom for deformable lung and liver CT and MR imaging for radiotherapy. Phys Med Biol 2020; 65:07NT02. [PMID: 32045898 DOI: 10.1088/1361-6560/ab7508] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
In this study, a functioning and ventilated anthropomorphic phantom was further enhanced for the purpose of CT and MR imaging of the lung and liver. A deformable lung, including respiratory tract was 3D printed. Within the lung's inner structures is a solid region shaped from a patient's lung tumour and six nitro-glycerine capsules as reference landmarks. The full internal mesh was coated, and the tumour filled, with polyorganosiloxane based gel. A moulded liver was created with an external casing of silicon filled with polyorganosiloxane gel and flexible plastic internal structures. The liver, fitted to the inferior portion of the right lung, moves along with the lung's ventilation. In the contralateral side, a cavity is designed to host a dosimeter, whose motion is correlated to the lung pressure. A 4DCT of the phantom was performed along with static and 4D T1 weighted MR images. The CT Hounsfield units (HU) for the flexible 3D printed material were -600-100 HU (lung and liver structures), for the polyorganosiloxane gel 30-120 HU (lung coating and liver filling) and for the silicon 650-800 HU (liver casing). The MR image intensity units were 0-40, 210-280 and 80-130, respectively. The maximum range of motion in the 4D imaging for the superior lung was 1-3.5 mm and 3.5-8 mm in the inferior portion. The liver motion was 5.5-8.0 mm at the tip and 5.7-10.0 mm at the dome. No measurable drift in motion was observed over a 2 h session and motion was reproducible over three different sessions for sin2(t), sin4(t) and a patient-like breathing curve with the interquartile range of amplitudes for all breathing cycles within 0.5 mm. The addition of features within the lung and of a deformable liver will allow the phantom to be used for imaging studies such as validation of 4DMRI and pseudo CT methods.
Collapse
Affiliation(s)
- Emma Colvill
- Paul Scherrer Institute, Center for Proton Therapy, Villigen, Switzerland. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|