Tai YC. High-resolution Imaging Using Virtual-Pinhole PET Concept. PET Clin 2024; 19:69-82. [PMID: 37775372 PMCID: PMC10840911 DOI: 10.1016/j.cpet.2023.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2023]
Abstract
Organ-specific PET scanners continues to draw interest for their high-resolution imaging capability that is unmatched by whole-body PET/computed tomography (CT) scanners. The virtual-pinhole PET concept offers new opportunities in PET system design, allowing one to mix and match detectors of different characteristics to achieve the highest performance such as high image resolution, high system sensitivity, and large imaging field-of-view. This novel approach delivers high-resolution PET images previously available only through organ-specific PET scanner while maintaining the imaging field-of-view of a clinical PET/CT scanner to see the entire body.
Collapse
Affiliation(s)
- Yuan-Chuan Tai
- Department of Radiology, Washington University in St. Louis, St Louis, MO, USA; Department of Biomedical Engineering, Washington University in St. Louis, St Louis, MO, USA; Department of Electrical and System Engineering, Washington University in St. Louis, St Louis, MO, USA.
| |
Collapse
|
2
|
Pommranz CM, Schmidt FP, Mannheim JG, Diebold SJ, Tenzer C, Santangelo A, Pichler BJ. Design and performance simulation studies of a breast PET insert integrable into a clinical whole-body PET/MRI scanner. Phys Med Biol 2023; 68. [PMID: 36753773 DOI: 10.1088/1361-6560/acba77] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 02/08/2023] [Indexed: 02/10/2023]
Abstract
Objective. Three different breast positron emission tomography (PET) insert geometries are proposed for integration into an existing magnetic resonance imaging (MRI) breast coil (Breast Biopsy Coil, NORAS MRI products) to be used inside a whole-body PET/MRI scanner (Biograph mMR, Siemens Healthineers) to enhance the sensitivity and spatial resolution of imaging inside the breast.Approach. Monte Carlo simulations were performed to predict and compare the performance characteristics of the three geometries in terms of the sensitivity, spatial resolution, scatter fraction, and noise equivalent count rate (NECR). In addition, the background single count rate due to organ uptake in a clinical scan scenario was predicted using a realistic anthropomorphic phantom.Main results. In the center of the field of view (cFOV), absolute sensitivities of 3.1%, 2.7%, and 2.2% were found for Geometry A (detectors arranged in two cylinders), Geometry B (detectors arranged in two partial cylinders), and Geometry C (detectors arranged in two half cylinders combined with two plates), respectively. The full width at half maximum spatial resolution was determined to be 1.7 mm (Geometry A), 1.8 mm (Geometry B) and 2.0 mm (Geometry C) at 5 mm from the cFOV. Designs with multiple scintillation-crystal layers capable of determining the depth of interaction (DOI) strongly improved the spatial resolution at larger distances from the transaxial cFOV. The system scatter fractions were 33.1% (Geometries A and B) and 32.3% (Geometry C). The peak NECRs occurred at source activities of 300 MBq (Geometry A), 310 MBq (Geometry B) and 340 MBq (Geometry C). The background single-event count rates were 17.1 × 106cps (Geometry A), 15.3 × 106cps (Geometry B) and 14.8 × 106cps (Geometry C). Geometry A in the three-layer DOI variant exhibited the best PET performance characteristics but could be challenging to manufacture. Geometry C had the lowest impact on the spatial resolution and the lowest sensitivity among the investigated geometries.Significance. Geometry B in the two-layer DOI variant represented an effective compromise between the PET performance and manufacturing difficulty and was found to be a promising candidate for the future breast PET insert.
Collapse
Affiliation(s)
- C M Pommranz
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Roentgenweg 13, D-72076 Tuebingen, Germany.,Institute for Astronomy and Astrophysics, Eberhard Karls University Tuebingen, Sand 1, D-72076 Tuebingen, Germany
| | - F P Schmidt
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Roentgenweg 13, D-72076 Tuebingen, Germany.,Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Otfried-Mueller-Strasse 14, D-72076 Tuebingen, Germany
| | - J G Mannheim
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Roentgenweg 13, D-72076 Tuebingen, Germany.,Cluster of Excellence iFIT (EXC 2180) Image Guided and Functionally Instructed Tumor Therapies, University of Tuebingen, Tuebingen, Germany
| | - S J Diebold
- Institute for Astronomy and Astrophysics, Eberhard Karls University Tuebingen, Sand 1, D-72076 Tuebingen, Germany
| | - C Tenzer
- Institute for Astronomy and Astrophysics, Eberhard Karls University Tuebingen, Sand 1, D-72076 Tuebingen, Germany
| | - A Santangelo
- Institute for Astronomy and Astrophysics, Eberhard Karls University Tuebingen, Sand 1, D-72076 Tuebingen, Germany
| | - B J Pichler
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Roentgenweg 13, D-72076 Tuebingen, Germany.,Cluster of Excellence iFIT (EXC 2180) Image Guided and Functionally Instructed Tumor Therapies, University of Tuebingen, Tuebingen, Germany
| |
Collapse
|
3
|
Wang Y, Herbst R, Abbaszadeh S. Development and Characterization of Modular Readout Design for Two-Panel Head-and-Neck Dedicated PET System Based on CZT Detectors. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:517-521. [PMID: 37711549 PMCID: PMC10500713 DOI: 10.1109/trpms.2021.3111547] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/16/2023]
Abstract
Cadmium zinc telluride (CZT) detectors are suitable for various applications due to the good energy resolution and the simple pixilation to achieve high spatial resolution. Our group is developing a two-panel head and neck dedicated positron emission tomography system based on CZT detectors. Each panel will consist of 150 CZT crystals (4×4×0.5 cm3) covering an area of 20×15 cm2 in an edge-on configuration to achieve high detector efficiency at 511 keV. In this work, we present the design and development of a full data acquisition chain that enables a low noise and compact readout for each panel. The initial results of the readout circuit were quantified using a 1 kHz square wave test pulse. The pulse amplitude was chosen to generate approximately the same amount of charges as a 511 keV photon would provide in CZT. The best-case FWHM electronic noise at 511 keV was measured to be 0.69% ± 0.16% (3.52 ± 0.81 in keV units after conversion). The FWHM electronic noise at 511 keV for a complete DAQ chain was 4.33% ± 0.30% (22.13 ± 1.53 in keV units).
Collapse
Affiliation(s)
- Yuli Wang
- Department of Electrical and Computer Engineering, University of California Santa Cruz, Santa Cruz, CA 95064, USA
| | - Ryan Herbst
- SLAC National Accelerator Labratory, 2575 Sand Hill Road, Menlo Park, CA, USA
| | - Shiva Abbaszadeh
- Department of Electrical and Computer Engineering, University of California Santa Cruz, Santa Cruz, CA 95064, USA
| |
Collapse
|
4
|
Abstract
Abstract
In this partial review and partial attempt at vision of what may be the future of dedicated brain PET scanners, the key implementations of the PET technique, we postulate that we are still on a development path and there is still a lot to be done in order to develop optimal brain imagers. Optimized for particular imaging tasks and protocols, and also mobile, that can be used outside the PET center, in addition to the expected improvements in sensitivity and resolution. For this multi-application concept to be more practical, flexible, adaptable designs are preferred. This task is greatly facilitated by the improved TOF performance that allows for more open, adjustable, limited angular coverage geometries without creating image artifacts. As achieving uniform very high resolution in the whole body is not practical due to technological limits and high costs, hybrid systems using a moderate-resolution total body scanner (such as J-PET) combined with a very high performing brain imager could be a very attractive approach. As well, as using magnification inserts in the total body or long-axial length imagers to visualize selected targets with higher resolution. In addition, multigamma imagers combining PET with Compton imaging should be developed to enable multitracer imaging.
Collapse
|
5
|
Ma T, Wei Q, Lyu Z, Zhang D, Zhang H, Wang R, Dong J, Liu Y, Yao R, He ZX. Self-Collimating SPECT With Multi-Layer Interspaced Mosaic Detectors. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:2152-2169. [PMID: 33852384 DOI: 10.1109/tmi.2021.3073288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Conventional single photon emission computed tomography (SPECT) relies on mechanical collimation whose resolution and sensitivity are interdependent, the best performance a SPECT system can attain is only a compromise of these two equally desired properties. To simultaneously achieve high resolution and sensitivity, we propose to use sensitive detectors constructed in a multi-layer in ter spaced mosaicdetectors (MATRICES) architecture to accomplish part of the collimation needed. We name this new approach self-collimation. We evaluate three self-collimating SPECT systems and report their imaging performance: 1) A simulated human brain SPECT achieves 3.88% sensitivity, it clearly resolves 0.5-mm and 1.0-mm hot-rod patterns at noise-free and realistic count-levels, respectively; 2) a simulated mouse SPECT achieves 1.25% sensitivity, it clearly resolves 50- [Formula: see text] and 100- [Formula: see text] hot-rod patterns at noise-free and realistic count-levels, respectively; 3) a SPECT prototype achieves 0.14% sensitivity and clearly separates 0.3-mm-diameter point sources of which the center-to-center neighbor distance is also 0.3 mm. Simulated contrast phantom studies show excellent resolution and signal-to-noise performance. The unprecedented system performance demonstrated by these 3 SPECT scanners is a clear manifestation of the superiority of the self-collimating approach over conventional mechanical collimation. It represents a potential paradigm shift in SPECT technology development.
Collapse
|
6
|
Kim H, Kao CM, Hua Y, Xie Q, Chen CT. Multiplexing Readout for Time-of-Flight (TOF) PET Detectors Using Striplines. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:662-670. [PMID: 34541433 PMCID: PMC8445371 DOI: 10.1109/trpms.2021.3051364] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A recent trend in PET instrumentation is the use of silicon photomultipliers (SiPMs) for high-resolution and time-of-flight (TOF) detection. Due to its small size, a PET system can use a large number of SiPMs and hence effective and scalable multiplexing readout methods become important. Unfortunately, multiplexing readout generally degrades the fast timing properties necessary for TOF, especially at high channel reduction. Previously, we developed a stripline (SL) based readout method for PET that uses a time-based multiplexing mechanism. This method maintains fast timing by design and has been successfully used for TOF PET detectors. In this paper, we present a more systematic study in which we examine how two important design parameters of the readout - the number of inputs on an SL (n SL) and the pathlength between adjacent input positions (Δℓ) - affect its detection performance properties for PET. Our result shows that, up to n SL = 32 the readout can achieve accurate pixel discrimination and causes little degradation in the energy resolution. The TOF resolution is compromised mildly and a coincidence resolving time on the order of 300 ps FWHM can be achieved for LYSO- and SiPM-based detectors. We also discuss strategies in using the readout to further reduce the number of electronic channels that a PET system would otherwise need.
Collapse
Affiliation(s)
- Heejong Kim
- Department of Radiology, University of Chicago, Chicago, IL 60637 USA
| | - Chien-Min Kao
- Department of Radiology, University of Chicago, Chicago, IL 60637 USA
| | - Yuexuan Hua
- Raycan Technology Co., Ltd., Suzhou, Jiangsu 215163, China
| | - Qingguo Xie
- Biomedical Engineering Department, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Chin-Tu Chen
- Department of Radiology, University of Chicago, Chicago, IL 60637 USA
| |
Collapse
|
7
|
Jiang J, Samanta S, Li K, Siegel SB, Mintzer RA, Cho S, Conti M, Schmand M, O'Sullivan J, Tai YC. Augmented Whole-Body Scanning via Magnifying PET. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:3268-3277. [PMID: 31899415 PMCID: PMC7673659 DOI: 10.1109/tmi.2019.2962623] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
A novel technique, called augmented whole-body scanning via magnifying PET (AWSM-PET), that improves the sensitivity and lesion detectability of a PET scanner for whole-body imaging is proposed and evaluated. A Siemens Biograph Vision PET/CT scanner equipped with one or two high-resolution panel-detectors was simulated to study the effectiveness of AWSM-PET technology. The detector panels are located immediately outside the scanner's axial field-of-view (FOV). A detector panel contains 2 ×8 detector modules each consisting of 32 ×64 LSO crystals ( 1.0 ×1.0 ×10.0 mm3 each). A 22Na point source was stepped across the scanner's FOV axially to measure sensitivity profiles at different locations. An elliptical torso phantom containing 7×9 spherical lesions was imaged at different axial locations to mimic a multi-bed-position whole-body imaging protocol. Receiver operating characteristic (ROC) curves were analyzed to evaluate the improvement in lesion detectability by the AWSM-PET technology. Experimental validation was conducted using an existing flat-panel detector integrated with a Siemens Biograph 40 PET/CT scanner to image a torso phantom containing spherical lesions with diameters ranging from 3.3 to 11.4 mm. The contrast-recovery-coefficient (CRC) of the lesions was evaluated for the scanner with or without the AWSM-PET technology. Monte Carlo simulation shows 36%-42% improvement in system sensitivity by a dual-panel AWSM-PET device. The area under the ROC curve is 0.962 by a native scanner for the detection of 4 mm diameter lesions with 5:1 tumor-to-background activity concentration. It was improved to 0.977 and 0.991 with a single- and dual-panel AWSM-PET system, respectively. Experimental studies showed that the average CRC of 3.3 mm and 4.3 mm diameter tumors were improved from 2.8% and 4.2% to 7.9% and 11.0%, respectively, by a single-panel AWSM-PET device. With a high-sensitivity dual-panel device, the corresponding CRC can be further improved to 11.0% and 15.9%, respectively. The principle of the AWSM-PET technology has been developed and validated. Enhanced system sensitivity, CRC and tumor detectability were demonstrated by Monte Carlo simulations and imaging experiments. This technology may offer a cost-effective path to realize high-resolution whole-body PET imaging clinically.
Collapse
|