Ren L, Zhou Z, Ahmed Z, Rajendran K, Fletcher JG, McCollough CH, Yu L. Performance evaluation of single- and dual-contrast spectral imaging on a photon-counting-detector CT. Med Phys 2024; 51:8034-8046. [PMID: 39235343 DOI: 10.1002/mp.17367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 07/02/2024] [Accepted: 07/23/2024] [Indexed: 09/06/2024] Open
Abstract
BACKGROUND The first commercially available photon-counting-detector CT (PCD-CT) has been introduced for clinical use. However, its spectral performance on single- and dual-contrast imaging tasks has not been comprehensively assessed. PURPOSE To evaluate the spectral imaging performance of a clinical PCD-CT system for single-contrast material [iodine (I) or gadolinium (Gd)] and dual-contrast materials (I and Gd) in comparison with a dual-source dual-energy CT (DS-DECT). METHODS Iodine (5, 10, and 15 mg/mL) and gadolinium (3.3, 6.6, and 9.9 mg/mL) samples, and their mixtures (I/Gd: 5/3.3 and 10/6.6 mg/mL) were prepared and placed in two torso-shaped water phantoms (lateral dimensions: 30 and 40 cm). These phantoms were scanned on a PCD-CT (NAEOTOM Alpha, Siemens) at 90, 120, and 140 kV. The same phantoms were scanned on a DS-DECT (SOMATOM Force, Siemens) with 70/Sn150, 80/Sn150, 90/Sn150, and 100/Sn150 kV. The radiation dose levels were matched [volume CT dose index (CTDIvol): 10 mGy for the 30 cm phantom and 20 mGy for the 40 cm phantom] across all tube voltage settings and between scanners. Two-material decomposition (I/water or Gd/water) was performed on iodine or gadolinium samples, and three-material decomposition (I/Gd/water) on both individual samples and mixtures. On each decomposed image, mean mass concentration (± standard deviation) was measured in circular region-of-interests placed on the contrast samples. Root-mean-square-error (RMSE) values of iodine and gadolinium concentrations were reported based on the measurements across all contrast samples and repeated on 10 consecutive slices. RESULTS For all material decomposition tasks on the DS-DECT, the kV pairs with greater spectral separation (70/Sn150 kV and 80/Sn150 kV) yielded lower RMSE values than other DS-DECT and PCD-CT alternatives. Specifically, for the optimal 70/Sn150 kV, RMSE values were 1.2 ± 0.1 mg/mL (I) for I/water material decomposition, 1.0 ± 0.1 mg/mL (Gd) for Gd/water material decomposition, and 4.5 ± 0.2 mg/mL (I) and 3.7 ± 0.2 mg/mL (Gd), respectively, for I/Gd/water material decomposition. On the PCD-CT, the optimal tube voltages were 120 or 140 kV for I/water decomposition with RMSE values of 2.0 ± 0.1 mg/mL (I). For Gd/water decomposition on PCD-CT, the optimal tube voltage was 140 kV with gadolinium RMSE values of 1.5 ± 0.1 mg/mL (Gd), with the 90 kV setting on PCD-CT generating higher RMSE values for gadolinium concentration compared to all DS-DECT and PCD-CT alternatives. For three material decomposition, both imaging modalities demonstrated substantially higher RMSE values for iodine and gadolinium, with 90 kV being the optimal tube potential for Gd/I quantitation on PCD-CT [5.4 ± 0.3 mg/mL (I) and 3.9 ± 0.2 mg/mL (Gd)], and DS-DECT at 100/Sn150 kV having larger RMSE values for both materials compared to the alternatives for either modality. CONCLUSION Optimal tube voltage for material decomposition on the clinical PCD-CT is task-dependent but inferior to DS-DECT using 70/Sn150 kV or 80/Sn150 kV in two-material decomposition for single-contrast imaging (iodine/water or gadolinium/water). Three material decomposition (iodine/gadolinium/water) in dual-contrast imaging yields substantially higher RMSE for both imaging platforms.
Collapse
Affiliation(s)
- Liqiang Ren
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
- Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Zhongxing Zhou
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Zaki Ahmed
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
- Department of Radiology, Corewell Health William Beaumont University Hospital, Royal Oak, Michigan, USA
| | | | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
2
|
Zou Y, Shi Y, Bi H, Tan J, Guo Q, Qin Y, Lu X, Ma X, Yang S, Liu J. A nomogram for risk stratification of central cervical lymph node metastasis in patients with papillary thyroid carcinoma. Quant Imaging Med Surg 2024; 14:5084-5098. [PMID: 39022275 PMCID: PMC11250316 DOI: 10.21037/qims-24-284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 06/13/2024] [Indexed: 07/20/2024]
Abstract
Background Whether to perform prophylactic central lymph node dissection for cN0 papillary thyroid carcinoma (PTC) patients is still controversial. This retrospective study aimed to develop and validate a nomogram based on ultrasound and dual-energy computed tomography (DECT) for the risk stratification of central lymph node metastasis (CLNM) in patients with PTC. Methods A total of 525 patients from 2017 to 2019 [Tianjin First Central Hospital (Hospital A)] were retrospectively analyzed to form the training cohort and to conduct internal validation. Another group of 204 patients in 2020 (Hospital A) formed the temporal validation cohort. A total of 107 patients in 2020 [Binzhou Medical University Hospital (Hospital B)] formed the geographic validation cohort, which was a retrospective cohort study. The area under the curve (AUC), calibration curve, and decision curve were used to evaluate the performance of the nomogram. The locally weighted regression curve was used for risk stratification. Results Diameter, taller-than-wide, calcification, capsular invasion, and iodine concentration in the arterial and venous phases were independent risk predictors of CLNM. The AUC of the nomogram was 0.922 (95% confidence interval: 0.895-0.943) in the training cohort. Two external validation cohorts demonstrated the good performance of the nomogram in predicting CLNM, with AUCs of 0.912 and 0.861. The significantly improved net reclassification index and integrated discriminatory improvement index indicated that DECT was a powerful supplement to ultrasound for predicting CLNM. The risk stratification system divided all patients into low-risk (0-50 points), intermediate-risk (51-100 points), and high-risk groups (>100 points). Conclusions The nomogram and risk stratification system estimated the utility of CLNM to guide individualized treatment of patients with PTC.
Collapse
Affiliation(s)
- Ying Zou
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, Tianjin, China
| | - Yan Shi
- Department of Ultrasonography, Weihai Municipal Hospital, Weihai, China
- Department of Ultrasonography, Binzhou Medical University Hospital, Binzhou, China
| | - Hai Bi
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
| | - Junyan Tan
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
| | - Qingwei Guo
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
| | - Yi Qin
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
| | - Xiudi Lu
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, Tianjin, China
| | - Xiaojing Ma
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
| | - Shouhong Yang
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
| | - Jihua Liu
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, China
- Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin, China
| |
Collapse
|
3
|
Ataei A, Vasan V, Soesbe TC, Brewington CC, Zhou Z, Yu L, Hallam KA, Ren L. Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT. SENSORS (BASEL, SWITZERLAND) 2024; 24:3567. [PMID: 38894358 PMCID: PMC11175174 DOI: 10.3390/s24113567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 05/24/2024] [Accepted: 05/30/2024] [Indexed: 06/21/2024]
Abstract
Simultaneous dual-contrast imaging of iodine and bismuth has shown promise in prior phantom and animal studies utilizing spectral CT. However, it is noted that in previous studies, Pepto-Bismol has frequently been employed as the source of bismuth, exceeding the recommended levels for human subjects. This investigation sought to assess the feasibility of visually differentiating and precisely quantifying low-concentration bismuth using clinical dual-source photon-counting CT (PCCT) in a scenario involving both iodinated and bismuth-based contrast materials. Four bismuth samples (0.6, 1.3, 2.5, and 5.1 mg/mL) were prepared using Pepto-Bismol, alongside three iodine rods (1, 2, and 5 mg/mL), inserted into multi-energy CT phantoms with three different sizes, and scanned on a PCCT system at three tube potentials (120, 140, and Sn140 kV). A generic image-based three-material decomposition method generated iodine and bismuth maps, with mean mass concentrations and noise levels measured. The root-mean-square errors for iodine and bismuth determined the optimal tube potential. The tube potential of 140 kV demonstrated optimal quantification performance when both iodine and bismuth were considered. Distinct differentiation of iodine rods with all three concentrations and bismuth samples with mass concentrations ≥ 1.3 mg/mL was observed across all phantom sizes at the optimal kV setting.
Collapse
Affiliation(s)
- Afrouz Ataei
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA
| | - Vasantha Vasan
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA
| | - Todd C. Soesbe
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA
| | | | - Zhongxing Zhou
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA
| | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA
| | | | - Liqiang Ren
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA
| |
Collapse
|
4
|
Ayala-Dominguez L, Medina LA, Aceves C, Lizano M, Brandan ME. Accuracy and Precision of Iodine Quantification in Subtracted Micro-Computed Tomography: Effect of Reconstruction and Noise Removal Algorithms. Mol Imaging Biol 2023; 25:1084-1093. [PMID: 37012518 PMCID: PMC10728260 DOI: 10.1007/s11307-023-01810-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 02/26/2023] [Accepted: 02/28/2023] [Indexed: 04/05/2023]
Abstract
PURPOSE To evaluate the effect of reconstruction and noise removal algorithms on the accuracy and precision of iodine concentration (CI) quantified with subtracted micro-computed tomography (micro-CT). PROCEDURES Two reconstruction algorithms were evaluated: a filtered backprojection (FBP) algorithm and a simultaneous iterative reconstruction technique (SIRT) algorithm. A 3D bilateral filter (BF) was used for noise removal. A phantom study evaluated and compared the image quality, and the accuracy and precision of CI in four scenarios: filtered FBP, filtered SIRT, non-filtered FBP, and non-filtered SIRT. In vivo experiments were performed in an animal model of chemically-induced mammary cancer. RESULTS Linear relationships between the measured and nominal CI values were found for all the scenarios in the phantom study (R2 > 0.95). SIRT significantly improved the accuracy and precision of CI compared to FBP, as given by their lower bias (adj. p-value = 0.0308) and repeatability coefficient (adj. p-value < 0.0001). Noise removal enabled a significant decrease in bias in filtered SIRT images only; non-significant differences were found for the repeatability coefficient. The phantom and in vivo studies showed that CI is a reproducible imaging parameter for all the scenarios (Pearson r > 0.99, p-value < 0.001). The contrast-to-noise ratio showed non-significant differences among the evaluated scenarios in the phantom study, while a significant improvement was found in the in vivo study when SIRT and BF algorithms were used. CONCLUSIONS SIRT and BF algorithms improved the accuracy and precision of CI compared to FBP and non-filtered images, which encourages their use in subtracted micro-CT imaging.
Collapse
Affiliation(s)
- Lízbeth Ayala-Dominguez
- Departamento de Física Experimental, Instituto de Física, Universidad Nacional Autónoma de México, Circuito de La Investigación Científica, Ciudad Universitaria UNAM, Mexico City, 04510, Mexico.
- Department of Medical Physics, University of Wisconsin, 1111 Highland Ave, WI, Madison, 53705, USA.
| | - Luis-Alberto Medina
- Departamento de Física Experimental, Instituto de Física, Universidad Nacional Autónoma de México, Circuito de La Investigación Científica, Ciudad Universitaria UNAM, Mexico City, 04510, Mexico
- Unidad de Investigación Biomédica en Cáncer INCan-UNAM, Instituto Nacional de Cancerología, Av. San Fernando 22, Tlalpan, Mexico City, 14080, Mexico
| | - Carmen Aceves
- Departamento de Neurobiología Celular Y Molecular, Instituto de Neurobiología, Universidad Nacional Autónoma de México, Boulevard Juriquilla 3001, Querétaro, Juriquilla, 76230, Mexico
| | - Marcela Lizano
- Unidad de Investigación Biomédica en Cáncer INCan-UNAM, Instituto Nacional de Cancerología, Av. San Fernando 22, Tlalpan, Mexico City, 14080, Mexico
- Departamento de Medicina Genómica Y Toxicología Ambiental, Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Circuito Exterior S/N, Ciudad Universitaria UNAM, Mexico City, 04510, Mexico
| | - Maria-Ester Brandan
- Departamento de Física Experimental, Instituto de Física, Universidad Nacional Autónoma de México, Circuito de La Investigación Científica, Ciudad Universitaria UNAM, Mexico City, 04510, Mexico
| |
Collapse
|
5
|
Thompson EA, Jacobsen MC, Fuentes DT, Layman RR, Cressman ENK. Quantitative dual-energy computed tomography with cesium as a novel contrast agent for localization of thermochemical ablation in phantoms and ex vivo models. Med Phys 2023; 50:7879-7890. [PMID: 37409792 PMCID: PMC10770302 DOI: 10.1002/mp.16558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 06/02/2023] [Accepted: 06/11/2023] [Indexed: 07/07/2023] Open
Abstract
BACKGROUND Thermochemical ablation (TCA) is a minimally invasive therapy under development for hepatocellular carcinoma. TCA simultaneously delivers an acid (acetic acid, AcOH) and base (sodium hydroxide, NaOH) directly into the tumor, where the acid/base chemical reaction produces an exotherm that induces local ablation. However, AcOH and NaOH are not radiopaque, making monitoring TCA delivery difficult. PURPOSE We address the issue of image guidance for TCA by utilizing cesium hydroxide (CsOH) as a novel theranostic component of TCA that is detectable and quantifiable with dual-energy CT (DECT). MATERIALS AND METHODS To quantify the minimum concentration of CsOH that can be positively identified by DECT, the limit of detection (LOD) was established in an elliptical phantom (Multi-Energy CT Quality Assurance Phantom, Kyoto Kagaku, Kyoto, Japan) with two DECT technologies: a dual-source system (SOMATOM Force, Siemens Healthineers, Forchheim, Germany) and a split-filter, single-source system (SOMATOM Edge, Siemens Healthineers). The dual-energy ratio (DER) and LOD of CsOH were determined for each system. Cesium concentration quantification accuracy was evaluated in a gelatin phantom before quantitative mapping was performed in ex vivo models. RESULTS On the dual-source system, the DER and LOD were 2.94 and 1.36-mM CsOH, respectively. For the split-filter system, the DER and LOD were 1.41- and 6.11-mM CsOH, respectively. The signal on cesium maps in phantoms tracked linearly with concentration (R2 = 0.99) on both systems with an RMSE of 2.56 and 6.72 on the dual-source and split-filter system, respectively. In ex vivo models, CsOH was detected following delivery of TCA at all concentrations. CONCLUSIONS DECT can be used to detect and quantify the concentration of cesium in phantom and ex vivo tissue models. When incorporated in TCA, CsOH performs as a theranostic agent for quantitative DECT image-guidance.
Collapse
Affiliation(s)
- Emily A Thompson
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Megan C Jacobsen
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - David T Fuentes
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Rick R Layman
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Erik N K Cressman
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
6
|
Lu S, Ren Y, Lu C, Qian X, Liu Y, Zhang J, Shan X, Sun E. Radiomics features from whole thyroid gland tissue for prediction of cervical lymph node metastasis in the patients with papillary thyroid carcinoma. J Cancer Res Clin Oncol 2023; 149:13005-13016. [PMID: 37466794 DOI: 10.1007/s00432-023-05184-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Accepted: 07/13/2023] [Indexed: 07/20/2023]
Abstract
OBJECTIVE We aimed to develop a clinical-radiomics nomogram that could predict the cervical lymph node metastasis (CLNM) of patients with papillary thyroid carcinoma (PTC) using clinical characteristics as well as radiomics features of dual energy computed tomography (DECT). METHOD Patients from our hospital with suspected PTC who underwent DECT for preoperative assessment between January 2021 and February 2022 were retrospectively recruited. Clinical characteristics were obtained from the medical record system. Clinical characteristics and rad-scores were examined by univariate and multivariate logistic regression. All features were incorporated into the LASSO regression model, with penalty parameter tuning performed using tenfold cross-validation, to screen risk factors for CLNM. An easily accessible radiomics nomogram was constructed. Receiver Operating Characteristic (ROC) curve together with Area Under the Curve (AUC) analysis was conducted to evaluate the discrimination performance of the model. Calibration curves were employed to assess the calibration performance of the clinical-radiomics nomogram, followed by goodness-of-fit testing. Decision curve analysis (DCA) was performed to determine the clinical utility of the established models by estimating net benefits at varying threshold probabilities for training and testing groups. RESULTS A total of 461 patients were retrospectively recruited. The rates of CLNM were 49.3% (70 /142) in the training cohort and 53.3% (32/60) in the testing cohort. Out of the 960 extracted radiomics features, 192 were significantly different in positive and negative groups (p < 0.05). On the basis of the training cohort, 12 stable features with nonzero coefficients were selected using LASSO regression. LASSO regression identified 7 risk factors for CLNM, including male gender, maximum tumor size > 10 mm, multifocality, CT-reported central CLN status, US-reported central CLN status, rad-score, and TGAb. A nomogram was developed using these factors to predict the risk of CLNM. The AUC values in each cohort were 0.850 and 0.797, respectively. The calibration curve together with the Hosmer-Lemeshow test for the nomogram indicated good agreement between predicted and pathological CLN statuses in the training and testing cohorts. Results of DCA proved that the nomogram offers a superior net benefit for predicting CLNM compared to the "treat all or none" strategy across the majority of risk thresholds. CONCLUSION A nomogram comprising the clinical characteristics as well as radiomics features of DECT and US was constructed for the prediction of CLNM for patients with PTC, which in determining whether lateral compartment neck dissection is warranted.
Collapse
Affiliation(s)
- Siyuan Lu
- Department of Radiology, Affiliated People's Hospital of Jiangsu University, Zhenjiang, 212002, Jiangsu Province, China
| | - Yongzhen Ren
- Department of Ultrasonography, Affiliated People's Hospital of Jiangsu University, Zhenjiang, 212002, Jiangsu Province, China
| | - Chao Lu
- Department of Radiology, Affiliated People's Hospital of Jiangsu University, Zhenjiang, 212002, Jiangsu Province, China
| | - Xiaoqin Qian
- Department of Ultrasonography, Affiliated People's Hospital of Jiangsu University, Zhenjiang, 212002, Jiangsu Province, China
| | - Yingzhao Liu
- Department of Endocrinology, Affiliated People's Hospital of Jiangsu University, Zhenjiang, 212002, Jiangsu Province, China
| | - Jiulou Zhang
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Xiuhong Shan
- Department of Radiology, Affiliated People's Hospital of Jiangsu University, Zhenjiang, 212002, Jiangsu Province, China.
| | - Eryi Sun
- Department of Neurosurgery, Affiliated People's Hospital of Jiangsu University, Zhenjiang, 212002, Jiangsu Province, China.
| |
Collapse
|
7
|
Zhou X, Zhang H, Jin X, Zhang X, Lu X, Han Q, Xiong X, Liu T, Feng Y, Tu W, Zhou T, Ge Y, Dong P, Liu S, Fan L. Ultra-low-dose spectral-detector computed tomography for the accurate quantification of pulmonary nodules: an anthropomorphic chest phantom study. Diagn Interv Radiol 2023; 29:691-703. [PMID: 37559745 PMCID: PMC10679552 DOI: 10.4274/dir.2023.232233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 07/06/2023] [Indexed: 08/11/2023]
Abstract
PURPOSE To assess the quantification accuracy of pulmonary nodules using virtual monoenergetic images (VMIs) derived from spectral-detector computed tomography (CT) under an ultra-low-dose scan protocol. METHODS A chest phantom consisting of 12 pulmonary nodules was scanned using spectral-detector CT at 100 kVp/10 mAs, 100 kVp/20 mAs, 120 kVp/10 mAs, and 120 kVp/30 mAs. Each scanning protocol was repeated three times. Each CT scan was reconstructed utilizing filtered back projection, hybrid iterative reconstruction, iterative model reconstruction (IMR), and VMIs of 40-100 keV. The signal-to-noise ratio and air noise of images, absolute differences, and absolute percentage measurement errors (APEs) of the diameter, density, and volume of the four scan protocols and ten reconstruction images were compared. RESULTS With each fixed reconstruction image, the four scanning protocols exhibited no significant differences in APEs for diameter and density (all P > 0.05). Of the four scan protocols and ten reconstruction images, APEs for nodule volume had no significant differences (all P > 0.05). At 100 kVp/10 mAs, APEs for density using IMR were the lowest (APE-mean: 6.69), but no significant difference was detected between VMIs at 50 keV (APE-mean: 11.69) and IMR (P = 0.666). In the subgroup analysis, at 100 kVp/10 mAs, there were no significant differences between VMIs at 50 keV and IMR in diameter and density (all P > 0.05). The radiation dose at 100 kVp/10 mAs was reduced by 77.8% compared with that at 120 kVp/30 mAs. CONCLUSION Compared with IMR, reconstruction at 100 kVp/10 mAs and 50 keV provides a more accurate quantification of pulmonary nodules, and the radiation dose is reduced by 77.8% compared with that at 120 kVp/30 mAs, demonstrating great potential for ultra-low-dose spectral-detector CT.
Collapse
Affiliation(s)
- Xiuxiu Zhou
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - Hanxiao Zhang
- Department of Radiology, Xuzhou Medical University, School of Medical Imaging, Xuzhou, China
| | - Xiaoxing Jin
- Department of Radiology Medicine, The Second People’s Hospital of Linhai, Linhai, China
| | - Xiaohui Zhang
- Department of Clinical Science, Philips Healthcare, Shanghai, China
| | - Xiaomei Lu
- CT Clinical Science, Philips Healthcare, Shanghai, China
| | - Qun Han
- Department of Clinical Science, Philips Healthcare, Shanghai, China
| | - Xiaoge Xiong
- School of Statistics and Management, Shanghai University of Finance and Economics, Shanghai, China
| | - Tian Liu
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - Yan Feng
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - Wenting Tu
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - Taohu Zhou
- Department of Radiology, Weifang Medical University, School of Medical Imaging, Shanghai, China
| | - Yanming Ge
- Department of Radiology, Weifang Medical University, School of Medical Imaging, Shanghai, China
| | - Peng Dong
- Department of Radiology, Weifang Medical University, School of Medical Imaging, Shanghai, China
| | - Shiyuan Liu
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| | - Li Fan
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China
| |
Collapse
|
8
|
An introduction to photon-counting detector CT (PCD CT) for radiologists. Jpn J Radiol 2023; 41:266-282. [PMID: 36255601 PMCID: PMC9974724 DOI: 10.1007/s11604-022-01350-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 10/01/2022] [Indexed: 10/24/2022]
Abstract
The basic performance of photon-counting detector computed tomography (PCD CT) is superior to conventional CT (energy-integrating detector CT: EID CT) because its spatial- and contrast resolution of soft tissues is higher, and artifacts are reduced. Because the X-ray photon energy separation is better with PCD CT than conventional EID-based dual-energy CT, it has the potential to improve virtual monochromatic- and virtual non-contrast images, material decomposition including quantification of the iodine distribution, and K-edge imaging. Therefore, its clinical applicability may be increased. Although the image quality of PCD CT scans is superior to that of EID CT currently, further improvement may be possible. The introduction of iterative image reconstruction and reconstruction with deep convolutional neural networks will be useful.
Collapse
|
9
|
Zou Y, Shi Y, Sun F, Liu J, Guo Y, Zhang H, Lu X, Gong Y, Xia S. Extreme gradient boosting model to assess risk of central cervical lymph node metastasis in patients with papillary thyroid carcinoma: Individual prediction using SHapley Additive exPlanations. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 225:107038. [PMID: 35930861 DOI: 10.1016/j.cmpb.2022.107038] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 07/02/2022] [Accepted: 07/22/2022] [Indexed: 05/06/2023]
Abstract
BACKGROUND AND OBJECTIVES Central cervical lymph node metastasis (CLNM) is considered a risk factor for recurrence in patients with papillary thyroid carcinoma (PTC). Traditional machine learning models suffered from "black-box" problems, which could not exactly explain the interactive effects of the risk factors. We aimed to develop an eXtreme Gradient Boosting (XGBoost) model to assess CLNM, including positive and negative effects. METHODS 1,122 patients with PTC admitted at Tianjin First Central Hospital from 2016 to 2020 were retrospectively selected. They were randomly divided into the training and test datasets with an 8:2 ratio. 108 patients with PTC admitted at Binzhou Medical University Hospital in 2020 served as the validation dataset. The XGBoost model was used to assess CLNM. The 10-fold cross-validation was utilized for model selection, and the metric used to evaluate classification performance was the average area under the curve (AUC) of 10-fold cross-validation. Interpretation and transparency of the "black-box" problem were performed. SHapley Additive exPlanations (SHAP) and local interpretable model-agnostic explanation (LIME) were used to ensure the stability and reliability of the model. RESULTS The XGBoost model based on ultrasound and dual-energy computed tomography images of the solitary primary lesion had an excellent performance for assessing CLNM, with average AUCs of 0.918, 0.903, and 0.881 in the training, test, and validation datasets, respectively. SHAP plots showed the influence of each parameter on the XGBoost model, including positive (i.e., capsular invasion, diameter, iodine concentration in the venous phase, and calcification) and negative (i.e., sex and age) impacts. For all cases, the capsular invasion prediction weight was the highest; for individual cases, different predictors were assigned different weights. Moreover, the performance of the XGBoost model was better than classical machine-learning models. CONCLUSIONS This study developed and validated an XGBoost model for assessing CLNM in patients with PTC. The ability to visually interpret the positive and negative effects made the XGBoost model an effective tool for guiding clinical treatment.
Collapse
Affiliation(s)
- Ying Zou
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, No. 314 Anshan West Road, Nan Kai District, Tianjin 300193, China; Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 314 Anshan West Road, Nan Kai District, Tianjin 300193, China
| | - Yan Shi
- Department of Ultrasonography, Binzhou Medical University Hospital, No. 661 Huanghe 2nd Road, Binzhou City, Shandong 256603, China
| | - Fang Sun
- Department of Ultrasonography, Binzhou Medical University Hospital, No. 661 Huanghe 2nd Road, Binzhou City, Shandong 256603, China
| | - Jihua Liu
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, No. 314 Anshan West Road, Nan Kai District, Tianjin 300193, China; Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 314 Anshan West Road, Nan Kai District, Tianjin 300193, China
| | - Yu Guo
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, No.24 Fukang Road, Nankai District, Tianjin 300192, China
| | - Huanlei Zhang
- Department of Radiologist, Yidu central hospital of Weifang, No. 4138 LingLongShan nan Road, Qing Zhou City, Shandong, 262500, China
| | - Xiudi Lu
- Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, No. 314 Anshan West Road, Nan Kai District, Tianjin 300193, China; Department of Radiology, National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, No. 314 Anshan West Road, Nan Kai District, Tianjin 300193, China
| | - Yan Gong
- Department of Radiology, Tianjin Hospital of ITCWM Nan Kai Hospital, No.6 Changjiang Road, Nan Kai District, Tianjin 300100, China
| | - Shuang Xia
- Department of Radiology, Tianjin First Central Hospital, School of Medicine, Nankai University, No.24 Fukang Road, Nankai District, Tianjin 300192, China.
| |
Collapse
|
10
|
Ren L, Huber N, Rajendran K, Fletcher JG, McCollough CH, Yu L. Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography: An Exploratory Animal Study. Invest Radiol 2022; 57:122-129. [PMID: 34411033 PMCID: PMC8732294 DOI: 10.1097/rli.0000000000000815] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The aims of this study were to develop a single-scan dual-contrast protocol for biphasic liver imaging with 2 intravenous contrast agents (iodine and gadolinium) and to evaluate its effectiveness in an exploratory swine study using a photon-counting detector computed tomography (PCD-CT) system. MATERIALS AND METHODS A dual-contrast CT protocol was developed for PCD-CT to simultaneously acquire 2 phases of liver contrast enhancement, with the late arterial phase enhanced by 1 contrast agent (iodine-based) and the portal venous phase enhanced by the other (gadolinium-based). A gadolinium contrast bolus (gadobutrol: 64 mL, 8 mL/s) and an iodine contrast bolus (iohexol: 40 mL, 5 mL/s) were intravenously injected in the femoral vein of a healthy domestic swine, with the second injection initiated after 17 seconds from the beginning of the first injection; PCD-CT image acquisition was performed 12 seconds after the beginning of the iodine contrast injection. A convolutional neural network (CNN)-based denoising technique was applied to PCD-CT images to overcome the inherent noise magnification issue in iodine/gadolinium decomposition task. Iodine and gadolinium material maps were generated using a 3-material decomposition method in image space. A set of contrast samples (mixed iodine and gadolinium) was attached to the swine belly; quantitative accuracy of material decomposition in these inserts between measured and true concentrations was calculated using root mean square error. An abdominal radiologist qualitatively evaluated the delineation of arterial and venous vasculatures in the swine liver using iodine and gadolinium maps obtained using the dual-contrast PCD-CT protocol. RESULTS The iodine and gadolinium samples attached to the swine were quantified with root mean square error values of 0.75 mg/mL for iodine and 0.45 mg/mL for gadolinium from the contrast material maps derived from the denoised PCD-CT images. Hepatic arteries containing iodine and veins containing gadolinium in the swine liver could be clearly visualized. Compared with the original images, better distinctions between 2 liver phases were achieved using CNN denoising, with approximately 60% to 80% noise reduction in contrast material maps acquired with the denoised PCD-CT images compared with the original images. CONCLUSIONS Simultaneous biphasic liver imaging in a single multienergy PCD-CT acquisition using a dual-contrast (iodine and gadolinium) injection protocol and CNN denoising was demonstrated in a swine study, where the enhanced hepatic arteries (containing iodine) and the enhanced hepatic veins (containing gadolinium) could be clearly visualized and delineated in the swine liver.
Collapse
Affiliation(s)
- Liqiang Ren
- From the Department of Radiology, Mayo Clinic, Rochester, MN
| | | | | | | | | | | |
Collapse
|
11
|
Zhou Z, Ren L, Rajendran K, Diehn FE, Fletcher JG, McCollough CH, Yu L. Simultaneous dual-contrast imaging using energy-integrating-detector multi-energy CT: An in vivo feasibility study. Med Phys 2022; 49:1458-1467. [PMID: 35018658 DOI: 10.1002/mp.15448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 12/12/2021] [Accepted: 12/17/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To demonstrate the feasibility of simultaneous dual-contrast imaging in a large animal using a newly developed dual-source energy-integrating-detector (EID) based multi-energy computed tomography (MECT) system. METHODS Two imaging tasks that may have potential clinical applications were investigated: head/neck (HN) CT angiography (CTA)/CT venography (CTV) with iodine and gadolinium, and small bowel imaging with iodine and bismuth in domestic swine. Dual-source x-ray beam configurations of 70 kV+Au120/Sn120 kV and 70 kV+Au140/Sn140 kV were used for the HN-CTA/CTV and small bowel imaging studies, respectively. A test bolus scan was performed for each study. The ROIs in the carotid artery and jugular vein for HN-CTA/CTV imaging and abdominal aorta for small bowel imaging were used to determine the time-attenuation curves, based on which the timing for contrast injection and the CT scan was determined. In the HN-CTA/CTV study, a MECT scan was performed at the time point corresponding to the optimal arterial enhancement by iodine and the optimal venous enhancement by gadolinium. In the small bowel imaging study, A MECT scan was performed at the optimal time point to simultaneously capture the mesenteric arterial enhancement of iodine and the enteric enhancement of bismuth. Image-based material decomposition was performed to decompose different materials for each study. To quantitatively characterize contrast material separation and misclassification, two ROIs on left common carotid artery and left internal jugular vein in HN-CTA/CTV imaging and three ROIs on superior mesenteric artery, ileal lumen, and collapsed ileum (ileal wall) in small bowel imaging were placed to measure the mean concentration values and the standard deviations. RESULTS In the HN-CTA/CTV study, common carotid arteries containing iodine and internal/external jugular veins containing gadolinium were clearly delineated from each other. Fine vessels such as cephalic veins and branches of external jugular veins were noticeable but clear visualization was hindered by image noise in gadolinium-specific (CTV) images, as reviewed by a neuro radiologist. In the small bowel imaging study, the mesenteric arteries and collapsed bowel wall containing iodine and the small bowel loops containing bismuth were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. Quantitative analyses showed that the misclassifications between the two contrast materials were less than 1.7 mg/mL and 0.1 mg/mL for CTA/CTV and small bowel imaging studies, respectively. CONCLUSIONS Feasibility of simultaneous CTA/CTV imaging in head and neck with iodine and gadolinium and simultaneous imaging of arterial and enteric phases of small bowel with iodine and bismuth, using a dual-source EID-MECT system, was demonstrated in a swine study. Compared to iodine and gadolinium in CTA/CTV, better delineation and classification of iodine and bismuth in small bowel imaging were achieved mainly due to wider separation between the corresponding two K-edge energies. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Zhongxing Zhou
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | - Liqiang Ren
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | | | - Felix E Diehn
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| |
Collapse
|
12
|
Ren L, Allmendinger T, Halaweish A, Schmidt B, Flohr T, McCollough CH, Yu L. Energy-integrating-detector multi-energy CT: Implementation and a phantom study. Med Phys 2021; 48:4857-4871. [PMID: 33988849 PMCID: PMC8455428 DOI: 10.1002/mp.14943] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 04/09/2021] [Accepted: 04/30/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Multi-energy computed tomography (MECT) has a great potential to enable many novel clinical applications such as simultaneous multi-contrast imaging. The purpose of this study was to implement triple-beam MECT on a traditional energy-integrating-detector (EID) CT platform (EID-MECT). METHODS This was accomplished by mounting a z-axis split-filter (0.05 mm Au, 0.6 mm Sn) on Tube A of a dual-source EID CT scanner. With the two split x-ray beams from Tube A and the third beam from Tube B, three beams with different x-ray spectra can be simultaneously acquired. With Tube B operated at 70 or 80 kV and Tube A at 120 or 140 kV, four different triple-beam configurations were calibrated for MECT measurements: 70/Au120/Sn120, 80/Au120/Sn120, 70/Au140/Sn140, and 80/Au140/Sn140 kV. Iodine (I), gadolinium (Gd), bismuth (Bi) samples, and their mixtures were prepared for 2 three-material-decomposition tasks and 1 four-material-decomposition task. For each task, samples were placed in a water phantom and scanned using each of the four triple-beam configurations. For comparison, the same phantom was also scanned using three other dual-energy CT (DECT) or MECT technologies: twin-beam DECT (TB-DECT), dual-source DECT (DS-DECT), and photon-counting-detector CT (PCD-CT), all with optimal x-ray spectrum settings and at equal volume CT dose index (CTDIvol). The phantom for four-material decomposition (I/Gd/Bi/Water imaging) was scanned using the PCD-CT only (140 kV with 25, 50, 75, and 90 keV). Image-based material decomposition was performed to acquire material-specific images, on which the mean basis material concentrations and noise levels were measured and compared across all triple-beam configurations in EID-MECT and various DECT/MECT systems. RESULTS The optimal triple-beam configuration was task-dependent with 70/Au120/Sn120, 70/Au140/Sn140, and 70/Au120/Sn120 kV for I/Gd/Water, I/Bi/Water, and I/Gd/Bi/Water material decomposition tasks, respectively. At equal radiation dose level, EID-MECT provided comparable or better quantification accuracy in material-specific images for all three material decomposition tasks, compared to EID-based DECT and PCD-CT systems. In terms of noise level comparison, EID-MECT-derived material-specific images showed lower noise levels than TB-DECT and DS-DECT, but slightly higher than that from PCD-CT in I/Gd/Water imaging. For I/Bi/Water imaging, EID-MECT showed a comparable noise level to DS-DECT, and a much lower noise level than TB-DECT and PCD-CT in all material-specific images. For the four-material decomposition task involving I/Gd/Bi/Water, the bismuth-specific image derived from EID-MECT was slightly noisier, but both iodine- and gadolinium-specific images showed much lower noise levels in comparison to PCD-CT. CONCLUSIONS For the first time, an EID-based MECT system that can simultaneously acquire three x-ray spectra measurements was implemented on a clinical scanner, which demonstrated comparable or better imaging performance than existing DECT and MECT systems.
Collapse
Affiliation(s)
- Liqiang Ren
- Department of Radiology, Mayo Clinic, Rochester, MN, US
| | | | | | | | | | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN, US
| |
Collapse
|
13
|
Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents. AJR Am J Roentgenol 2021; 218:290-299. [PMID: 34406059 DOI: 10.2214/ajr.21.26345] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND. The value of dual-energy CT (DECT) for bowel wall assessment is increasingly recognized. Although technical improvements reduce peristalsis artifact in conventional CT, the effects of peristalsis on DECT image reconstructions remain poorly studied. OBJECTIVE. The purpose of this study was to evaluate the influence of different DECT scanners and enteric contrast agents on the severity of bowel peristalsis artifact in vitro. METHODS. To simulate bowel peristalsis, a 3-cm-diameter corrugated hollow tube representing the bowel was oscillated constantly in the z-axis within a larger water-filled cylinder. The bowel was serially filled with air, water, and iodinated or experimental dark contrast material and scanned on four different DECT platforms (spectral detector, rapid peak kilovoltage switching, split filter, and dual source) to reconstruct 120-kVp-like and iodine images. Two readers rated each image reconstruction for artifact severity from 0 (none) to 3 (severe) and recorded the degree to which iodine images depicted bowel wall hyperattenuation on 120-kVp-like images as artifactual. Artifact severity scores were compared by ANOVA with Bonferroni correction. RESULTS. Interrater agreement on artifact scores was excellent (intraclass correlation coefficient, 0.82 [95% CI, 0.79-0.84]). For 120-kVp-like images, mean peristalsis artifact scores were lower (all p < .001) for split-filter (1.47) and dual-source (1.86) scanners than for spectral-detector (2.58) and rapid-kilovoltage-switching (2.74) scanners. Compared with those on 120-kVp images, peristalsis artifacts on iodine images were less severe for spectral-detector (score, 1.03; p < .001) and rapid-kilovoltage-switching (2.09; p < .001) systems but more severe for dual-source (2.77; p < .001) and split-filter (2.62; p < .001) systems. Peristalsis artifact was rated less severe with experimental dark bowel contrast medium (score, 1.79) than with other bowel contrast agents (all p < .001). Iodine images helped identify bowel wall hyperattenuation as artifactual in 94.7% of reviewed cases for spectral-detector and 40.7% of cases for rapid-kilovoltage-switching scanners. CONCLUSION. For spectral-detector and rapid-kilovoltage-switching DECT, iodine images minimize peristalsis artifact, but for dual-source and split-filter DECT, mixed 120-kVp-like images are preferred. Compared with iodinated contrast material and water, experimental dark bowel contrast material reduces peristalsis artifact. CLINICAL IMPACT. Knowledge of the preferred images for reducing peristalsis artifact can lessen the effect of peristalsis on clinical DECT interpretation. Dark enteric contrast agents, when they become clinically available, may further reduce the effects of peristalsis.
Collapse
|
14
|
Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography: A Feasibility Animal Study. Invest Radiol 2021; 55:688-694. [PMID: 32530868 DOI: 10.1097/rli.0000000000000687] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
OBJECTIVES Dual-energy and multienergy computed tomography (DECT/MECT) has the potential to simultaneously visualize two contrast agents in the small bowel: arterial enhancement of iodine in the bowel wall and enteric enhancement of bismuth in the bowel lumen. The purpose of this study was to explore its feasibility in a swine study using a research whole-body photon-counting-detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS A phantom study was initially performed to evaluate the quantification accuracy of iodine and bismuth separation from a single PCD-CT scan, which also served as the calibration reference for material decomposition of in vivo swine PCD-CT data. In the animal study, a test bolus scan was first performed to determine the time-attenuation curve for the arterial enhancement, based on which the timing of the PCD-CT dual-contrast scan was determined. A 600 mL homogeneous bismuth-saline solution (180 mL Pepto-Bismol + 420 mL normal saline) was orally administered to the pig using esophageal intubation. Approximately 1 hour after bismuth administration, 40 mL iodine contrast (Omnipaque 350, 5 mL/s) was injected intravenously. A PCD-CT scan was performed 13 seconds after the initiation of the contrast injection to simultaneously capture the arterial enhancement of iodine and the enteric enhancement of bismuth. To provide optimal material separation and quantification, all PCD-CT scans in both phantom and animal studies were operated at 140 kV with 4 energy thresholds of 25, 50, 75, and 90 keV. RESULTS Using a generic image-based material decomposition method, the iodine and bismuth samples were successfully delineated and quantified in the phantom images with a root-mean-square-error of 1.32 mg/mL in iodine measurement and 0.64 mg/mL in bismuth measurement. In the pig study, the enhancing bowel wall containing iodine and the small bowel loop containing bismuth were not differentiable in the original PCD-CT images. However, they were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. In addition, quantitative analysis showed that the misclassification between the two contrast materials was less than 1.0 mg/mL. CONCLUSIONS Our study demonstrated the feasibility of simultaneous imaging of iodine and bismuth in small bowel of swine using PCD-CT.
Collapse
|
15
|
Ding H, Wang C, Malkasian S, Johnson T, Molloi S. Characterization of arterial plaque composition with dual energy computed tomography: a simulation study. Int J Cardiovasc Imaging 2020; 37:331-341. [PMID: 32876901 DOI: 10.1007/s10554-020-01961-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 08/03/2020] [Indexed: 12/27/2022]
Abstract
To investigate the feasibility of quantifying the chemical composition of coronary artery plaque in terms of water, lipid, protein, and calcium contents using dual-energy computed tomography (CT) in a simulation study. A CT simulation package was developed based on physical parameters of a clinical CT scanner. A digital thorax phantom was designed to simulate coronary arterial plaques in the range of 2-5 mm in diameter. Both non-calcified and calcified plaques were studied. The non-calcified plaques were simulated as a mixture of water, lipid, and protein, while the calcified plaques also contained calcium. The water, lipid, protein, and calcium compositions of the plaques were selected to be within the expected clinical range. A total of 95 plaques for each lesion size were simulated using the CT simulation package at 80 and 135 kVp. Half-value layer measurements were made to make sure the simulated dose was within the range of clinical dual energy scanning protocols. Dual-energy material decomposition using a previously developed technique was performed to determine the volumetric fraction of water, lipid, protein, and calcium contents in each plaque. For non-calcified plaque, the total volume conservation provides the third constrain for three-material decomposition with dual energy CT. For calcified plaque, a fourth criterion was introduced from a previous report suggesting a linear correlation between water and protein contents in soft tissue. For non-calcified plaque, the root mean-squared error (RMSE) of the image-based decomposition was estimated to be 0.7%, 1.5%, and 0.3% for water, lipid, and protein contents, respectively. As for the calcified plaques, the RMSE of the 5 mm plaques were estimated to be 5.6%, 5.7%, 0.2%, and 3.1%, for water, lipid, calcium, and protein contents, respectively. The RMSE increases as the plaque size reduces. The simulation results indicate that chemical composition of coronary arterial plaques can be quantified using dual-energy CT. By accurately quantifying the content of a coronary plaque lesion, our decomposition method may provide valuable insight for the assessment and stratification of coronary artery disease.
Collapse
Affiliation(s)
- Huanjun Ding
- Department of Radiological Sciences, University of California, Irvine, CA, 92697, USA.
| | - Chenggong Wang
- Department of Radiological Sciences, University of California, Irvine, CA, 92697, USA
| | - Shant Malkasian
- Department of Radiological Sciences, University of California, Irvine, CA, 92697, USA
| | - Travis Johnson
- Department of Radiological Sciences, University of California, Irvine, CA, 92697, USA
| | - Sabee Molloi
- Department of Radiological Sciences, University of California, Irvine, CA, 92697, USA
| |
Collapse
|
16
|
Ren L, Rajendran K, McCollough CH, Yu L. Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging. Phys Med Biol 2019; 64:245003. [PMID: 31703217 PMCID: PMC6980362 DOI: 10.1088/1361-6560/ab55bf] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Compared to traditional multi-scan single-energy CT (SECT), one potential advantage of single-scan multi-energy CT (MECT) proposed for simultaneous imaging of multiple contrast agents is the radiation dose reduction. This phantom study aims to rigorously evaluate whether the radiation dose can truly be reduced in a single-scan MECT protocol (MECT_1s) in biphasic liver imaging with iodine and gadolinium, and small bowel imaging with iodine and bismuth, compared to traditional two-scan SECT protocols (SECT_2s). For MECT_1s, mixed iodine/gadolinium samples were prepared corresponding to late arterial/portal-venous phase for biphasic liver imaging. Mixed iodine/bismuth samples were prepared representing the arterial/enteric enhancement for small bowel imaging. For SECT_2s, separate contrast samples were prepared to mimic separate scans in arterial/venous phase and arterial/enteric enhancement. Samples were placed in a 35 cm wide water phantom and scanned by a research whole-body photon-counting-detector-CT (PCD-CT) system ('chess' mode). MECT images were acquired with optimized kV/threshold settings for each imaging task, and SECT images were acquired at 120 kV. Total CTDIvol was matched for the two protocols. Image-based three-material decomposition was employed in MECT_1s to determine the basis material concentration values, which were converted to CT numbers at 120 kV (i.e. virtual SECT images) to compare with the SECT images directly acquired with SECT_2s. The noise difference between the SECT and the virtual SECT images was compared to evaluate the dose efficiency of MECT_1s. Compared to SECT_2s, MECT_1s was not dose efficient for both imaging tasks. The amount of noise increase is highly task dependent, with noise increased by 203%/278% and 110%/82% in virtual SECT images for iodine/gadolinium and iodine/bismuth quantifications, respectively, corresponding to dose increase by 819%/1328% and 340%/230% in MECT_1s to achieve the same image noise level. MECT with the current PCD-CT technique requires higher radiation dose than SECT to achieve the same image quality.
Collapse
Affiliation(s)
- Liqiang Ren
- Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, MN 55902, United States of America
| | - Kishore Rajendran
- Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, MN 55902, United States of America
| | - Cynthia H McCollough
- Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, MN 55902, United States of America
| | - Lifeng Yu
- Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, MN 55902, United States of America
| |
Collapse
|