1
|
Nakano H, Takizawa T, Kawahara D, Tanabe S, Utsunomiya S, Kaidu M, Maruyama K, Takeuchi S, Onda K, Koizumi M, Nishio T, Ishikawa H. Radiobiological evaluation considering the treatment time with stereotactic radiosurgery for brain metastases. BJR Open 2022; 4:20220013. [PMID: 38525167 PMCID: PMC10958663 DOI: 10.1259/bjro.20220013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 10/04/2022] [Accepted: 10/27/2022] [Indexed: 12/15/2022] Open
Abstract
Objective We evaluated the radiobiological effect of the irradiation time with the interruption time of stereotactic radiosurgery (SRS) using CyberKnife® (CK) systemfor brain metastases. Methods We used the DICOM data and irradiation log file of the 10 patients with brain metastases from non-small-cell lung cancer (NSCLC) who underwent brain SRS. We defined the treatment time as the sum of the dose-delivery time and the interruption time during irradiations, and we used a microdosimetric kinetic model (MKM) to evaluate the radiobiological effects of the treatment time. The biological parameters, i.e. α0, β0, and the DNA repair constant rate (a + c), were acquired from NCI-H460 cell for the MKM. We calculated the radiobiological dose for the gross tumor volume (GTVbio) to evaluate the treatment time's effect compared with no treatment time as a reference. The D95 (%) and the Radiation Therapy Oncology Group conformity index (RCI) and Paddick conformity index (PCI) were calculated as dosimetric indices. We used several DNA repair constant rates (a + c) (0.46, 1.0, and 2.0) to assess the radiobiological effect by varying the DNA repair date (a + c) values. Results The mean values of D95 (%), RCI, and PCI for GTVbio were 98.8%, 0.90, and 0.80, respectively, and decreased with increasing treatment time. The mean values of D95 (%), RCI, and PCI of GTVbio at 2.0 (a+c) value were 94.9%, 0.71, and 0.49, respectively. Conclusion The radiobiological effect of the treatment time on tumors was accurately evaluated with brain SRS using CK. Advances in knowledge There has been no published investigation of the radiobiological impact of the longer treatment time with multiple interruptions of SRS using a CK on the target dose distribution in a comparison with the use of a linac. Radiobiological dose assessment that takes into account treatment time in the physical dose in this study may allow more accurate dose assessment in SRS for metastatic brain tumors using CK.
Collapse
Affiliation(s)
| | | | - Daisuke Kawahara
- Department of Radiation Oncology, Institute of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima-shi, Hiroshima, Japan
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Katsuya Maruyama
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata-shi, Niigata, Japan
| | - Shigekazu Takeuchi
- Department of Neurosurgery, Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata-shi, Niigata, Japan
| | - Kiyoshi Onda
- Department of Neurosurgery, Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata-shi, Niigata, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| |
Collapse
|
2
|
Biological Dose Optimization for Particle Arc Therapy using Helium and Carbon Ions. Int J Radiat Oncol Biol Phys 2022; 114:334-348. [PMID: 35490991 DOI: 10.1016/j.ijrobp.2022.04.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 04/11/2022] [Accepted: 04/19/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE To present biological dose optimization for particle arc therapy using helium and carbon ions. METHODS Treatment plan planning and optimization procedures were developed for spot-scanning hadron arc (SHArc) delivery using the RayStation TPS and a GPU-accelerated dose engine (†TPS-XXX). The SHArc optimization algorithm is applicable for charged particle beams and determines angle-dependencies for spot/energy selection with three main initiatives: i) achieve standard clinical optimization goals and constraints for target and OARs, ii) target dose robustness and iii) increasing LET in the target volume. Three patient cases previously treated at the †INSTITUTION-XXX were selected for evaluation of conventional versus arc delivery for the two clinical particle beams (helium [4He] and carbon [12C] ions): glioblastoma, prostate-adenocarcinoma and skull-base chordoma. Biological dose and dose-averaged linear energy transfer (LETd) distributions for SHArc were evaluated against conventional planning techniques (VMAT and IMPT2F) applying the modified microdosimetric kinetic model (mMKM) for considering bio-effect with (α/β)x=2Gy. Clinical viability and deliverability were assessed via evaluation of plan quality, robustness and irradiation time. RESULTS For all investigated patient cases, SHArc treatment optimizations met planning goals and constraints for target coverage and OARs, exhibiting acceptable target coverage and reduced normal tissue volumes with effective dose >10GyRBE compared to conventional 2F planning. For carbon ions, LETd was increased in the target volume from ∼40-60keV/µm to ∼80-140keV/µm for SHArc compared to conventional treatments. Favorable LETd distributions were possible with the SHArc approach, with maximum LETd in CTV/GTV and potential reductions of high-LET regions in normal tissues and OARs. Compared to VMAT, SHArc affords substantial reductions in normal tissue dose (40-70%). CONCLUSION SHArc therapy offers potential treatment benefits such as increased normal tissue sparing from higher doses >10GyRBE, enhanced target LETd, and potential reduction in high-LET components in OARs. Findings justify further development of robust SHArc treatment planning towards potential clinical translation.
Collapse
|
3
|
Kasamatsu K, Tanaka S, Miyazaki K, Takao S, Miyamoto N, Hirayama S, Nishioka K, Hashimoto T, Aoyama H, Umegaki K, Matsuura T. Impact of a spatially dependent dose delivery time structure on the biological effectiveness of scanning proton therapy. Med Phys 2021; 49:702-713. [PMID: 34796522 DOI: 10.1002/mp.15367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 10/09/2021] [Accepted: 11/02/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE In the scanning beam delivery of protons, different portions of the target are irradiated with different linear energy transfer protons with various time intervals and irradiation times. This research aimed to evaluate the spatially dependent biological effectiveness of protracted irradiation in scanning proton therapy. METHODS One and two parallel opposed fields plans were created in water phantom with the prescribed dose of 2 Gy. Three scenarios (instantaneous, continuous, and layered scans) were used with the corresponding beam delivery models. The biological dose (physical dose × relative biological effectiveness) was calculated using the linear quadratic model and the theory of dual radiation action to quantitatively evaluate the dose delivery time effect. In addition, simulations using clinical plans (postoperative seminoma and prostate tumor cases) were conducted to assess the impact of the effects on the dose volume histogram parameters and homogeneity coefficient (HC) in targets. RESULTS In a single-field plan of water phantom, when the treatment time was 19 min, the layered-scan scenario showed a decrease of <0.2% (almost 3.3%) in the biological dose from the plan on the distal (proximal) side because of the high (low) dose rate. This is in contrast to the continuous scenario, where the biological dose was almost uniformly decreased over the target by approximately 3.3%. The simulation with clinical geometry showed that the decrease rates in D99% were 0.9% and 1.5% for every 10 min of treatment time prolongation for postoperative seminoma and prostate tumor cases, respectively, whereas the increase rates in HC were 0.7% and 0.2%. CONCLUSIONS In protracted irradiation in scanning proton therapy, the spatially dependent dose delivery time structure in scanning beam delivery can be an important factor for accurate evaluation of biological effectiveness.
Collapse
Affiliation(s)
- Koki Kasamatsu
- Graduate School of Biomedical Science and Engineering, Hokkaido University, Sapporo, Japan
| | - Sodai Tanaka
- Faculty of Engineering, Hokkaido University, Sapporo, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Koichi Miyazaki
- Faculty of Engineering, Hokkaido University, Sapporo, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Seishin Takao
- Faculty of Engineering, Hokkaido University, Sapporo, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan.,Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Japan
| | - Naoki Miyamoto
- Faculty of Engineering, Hokkaido University, Sapporo, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | | | - Kentaro Nishioka
- Department of Radiation Medical Science and Engineering, Faculty of Medicine, Hokkaido University, Sapporo, Japan
| | - Takayuki Hashimoto
- Department of Radiation Medical Science and Engineering, Faculty of Medicine, Hokkaido University, Sapporo, Japan
| | - Hidefumi Aoyama
- Department of Radiation Oncology, Faculty of Medicine, Hokkaido University, Sapporo, Japan
| | - Kikuo Umegaki
- Faculty of Engineering, Hokkaido University, Sapporo, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan.,Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Japan
| | - Taeko Matsuura
- Faculty of Engineering, Hokkaido University, Sapporo, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan.,Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Japan
| |
Collapse
|
4
|
Comparison of FLASH Proton Entrance and the Spread-Out Bragg Peak Dose Regions in the Sparing of Mouse Intestinal Crypts and in a Pancreatic Tumor Model. Cancers (Basel) 2021; 13:cancers13164244. [PMID: 34439398 PMCID: PMC8392865 DOI: 10.3390/cancers13164244] [Citation(s) in RCA: 63] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/14/2021] [Accepted: 08/19/2021] [Indexed: 12/15/2022] Open
Abstract
Simple Summary FLASH radiotherapy is a treatment technique of interest that involves radiation delivered at ultra-high dose rates >100 times faster than traditional radiation therapy, which has been shown to spare radiation damage to normal tissue but maintain tumor control capabilities. Proton therapy uses spread-out proton Bragg peaks to reduce radiation dose to normal tissue by directing the highest dose of radiation to the tumor volume. In this study, irradiation of the whole abdomen of mice was performed with proton beams at FLASH dose rates in order to investigate the normal tissue sparing capabilities of the spread-out Bragg peak compared to the entrance region of the proton depth dose curve. Abstract Ultra-high dose rate FLASH proton radiotherapy (F-PRT) has been shown to reduce normal tissue toxicity compared to standard dose rate proton radiotherapy (S-PRT) in experiments using the entrance portion of the proton depth dose profile, while proton therapy uses a spread-out Bragg peak (SOBP) with unknown effects on FLASH toxicity sparing. To investigate, the biological effects of F-PRT using an SOBP and the entrance region were compared to S-PRT in mouse intestine. In this study, 8–10-week-old C57BL/6J mice underwent 15 Gy (absorbed dose) whole abdomen irradiation in four groups: (1) SOBP F-PRT, (2) SOBP S-PRT, (3) entrance F-PRT, and (4) entrance S-PRT. Mice were injected with EdU 3.5 days after irradiation, and jejunum segments were harvested and preserved. EdU-positive proliferating cells and regenerated intestinal crypts were quantified. The SOBP had a modulation (width) of 2.5 cm from the proximal to distal 90%. Dose rates with a SOBP for F-PRT or S-PRT were 108.2 ± 8.3 Gy/s or 0.82 ± 0.14 Gy/s, respectively. In the entrance region, dose rates were 107.1 ± 15.2 Gy/s and 0.83 ± 0.19 Gy/s, respectively. Both entrance and SOBP F-PRT preserved a significantly higher number of EdU + /crypt cells and percentage of regenerated crypts compared to S-PRT. Moreover, tumor growth studies showed no difference between SOBP and entrance for either of the treatment modalities.
Collapse
|