Robitaille M, Ménard C, Famulari G, Béliveau-Nadeau D, Enger SA. 169Yb-based high dose rate intensity modulated brachytherapy for focal treatment of prostate cancer. Brachytherapy 2024; 23:523-534. [PMID: 39038997 DOI: 10.1016/j.brachy.2024.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 04/24/2024] [Accepted: 05/20/2024] [Indexed: 07/24/2024]
Abstract
PURPOSE This study compares conventional 192Ir-based high dose rate brachytherapy (HDR-BT) with 169Yb-based HDR intensity modulated brachytherapy (IMBT) for focal prostate cancer treatment. Additionally, the study explores the potential to generate less invasive treatment plans with IMBT by reducing the number of catheters needed to achieve acceptable outcomes. METHODS AND MATERIALS A retrospective dosimetric study of ten prostate cancer patients initially treated with conventional 192Ir-based HDR-BT and 5-14 catheters was employed. RapidBrachyMCTPS, a Monte Carlo-based treatment planning system was used to calculate and optimize dose distributions. For 169Yb-based HDR IMBT, a custom 169Yb source combined with 0.8 mm thick platinum shields placed inside 6F catheters was used. Furthermore, dose distributions were investigated when iteratively removing catheters for less invasive treatments. RESULTS With IMBT, the urethra D10 and D0.1cc decreased on average by 15.89 and 15.65 percentage points (pp) and the rectum V75 and D2cc by 1.53 and 11.54 pp, respectively, compared to the conventional clinical plans. Similar trends were observed when the number of catheters decreased. On average, there was an observed increase in PTV V150 from 2.84 pp with IMBT when utilizing all catheters to 8.83 pp when four catheters were removed. PTV V200 increased from 0.42 to 2.96 pp on average. Hotspots in the body were however lower with IMBT compared to conventional clinical plans. CONCLUSIONS 169Yb-based HDR IMBT for focal treatment of prostate cancer has the potential to successfully deliver clinically acceptable, less invasive treatment with reduced dose to organs at risk.
Collapse
Affiliation(s)
- Maude Robitaille
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, Quebec, Canada; Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, Quebec, Canada.
| | - Cynthia Ménard
- Department of Radiation Oncology, CHUM, Montreal, Quebec, Canada
| | - Gabriel Famulari
- Department of Radiation Oncology, Jewish General Hospital, Montreal, Quebec, Canada; Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, Quebec, Canada
| | | | - Shirin A Enger
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, Quebec, Canada; Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
2
|
Jafarzadeh H, Antaki M, Mao X, Duclos M, Maleki F, Enger SA. Penalty weight tuning in high dose rate brachytherapy using multi-objective Bayesian optimization. Phys Med Biol 2024; 69:115024. [PMID: 38670145 DOI: 10.1088/1361-6560/ad4448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 04/26/2024] [Indexed: 04/28/2024]
Abstract
Objective.Treatment plan optimization in high dose rate brachytherapy often requires manual fine-tuning of penalty weights for each objective, which can be time-consuming and dependent on the planner's experience. To automate this process, this study used a multi-criteria approach called multi-objective Bayesian optimization with q-noisy expected hypervolume improvement as its acquisition function (MOBO-qNEHVI).Approach.The treatment plans of 13 prostate cancer patients were retrospectively imported to a research treatment planning system, RapidBrachyMTPS, where fast mixed integer optimization (FMIO) performs dwell time optimization given a set of penalty weights to deliver 15 Gy to the target volume. MOBO-qNEHVI was used to find patient-specific Pareto optimal penalty weight vectors that yield clinically acceptable dose volume histogram metrics. The relationship between the number of MOBO-qNEHVI iterations and the number of clinically acceptable plans per patient (acceptance rate) was investigated. The performance time was obtained for various parameter configurations.Main results.MOBO-qNEHVI found clinically acceptable treatment plans for all patients. With increasing the number of MOBO-qNEHVI iterations, the acceptance rate grew logarithmically while the performance time grew exponentially. Fixing the penalty weight of the tumour volume to maximum value, adding the target dose as a parameter, initiating MOBO-qNEHVI with 25 parallel sampling of FMIO, and running 6 MOBO-qNEHVI iterations found solutions that delivered 15 Gy to the hottest 95% of the clinical target volume while respecting the dose constraints to the organs at risk. The average acceptance rate for each patient was 89.74% ± 8.11%, and performance time was 66.6 ± 12.6 s. The initiation took 22.47 ± 7.57 s, and each iteration took 7.35 ± 2.45 s to find one Pareto solution.Significance.MOBO-qNEHVI combined with FMIO can automatically explore the trade-offs between treatment plan objectives in a patient specific manner within a minute. This approach can reduce the dependency of plan quality on planner's experience and reduce dose to the organs at risk.
Collapse
Affiliation(s)
- Hossein Jafarzadeh
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, Canada
| | - Majd Antaki
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, Canada
| | - Ximeng Mao
- mila-Quebec AI Institute, Montréal, Quebec, Canada
| | - Marie Duclos
- McGill University Health Center, Montreal, Canada
| | - Farhard Maleki
- Department of Computer Science, University of Calgary, Calgary, AB, Canada
| | - Shirin A Enger
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, Canada
- mila-Quebec AI Institute, Montréal, Quebec, Canada
- Lady Davis Institute for Medical Research, Montreal, Quebec, Canada
| |
Collapse
|
3
|
Flynn RT, Smith BR, Adams QE, Patwardhan K, Graves SA, Hopfensperger KM. A re-activation model for 169Yb intensity modulated brachytherapy sources accounting for spatiotemporal isotopic composition. Med Phys 2024; 51:3604-3618. [PMID: 38558460 DOI: 10.1002/mp.17048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/04/2024] Open
Abstract
BACKGROUND Intensity modulated brachytherapy based on partially shielded intracavitary and interstitial applicators is possible with a cost-effective 169Yb production method. 169Yb is a traditionally expensive isotope suitable for this purpose, with an average γ-ray energy of 93 keV. Re-activating a single 169Yb source multiple times in a nuclear reactor between clinical uses was shown to theoretically reduce cost by approximately 75% relative to conventional single-activation sources. With re-activation, substantial spatiotemporal variation in isotopic source composition is expected between activations via 168Yb burnup and 169Yb decay, resulting in time dependent neutron transmission, precursor usage, and reactor time needed per re-activation. PURPOSE To introduce a generalized model of radioactive source production that accounts for spatiotemporal variation in isotopic source composition to improve the efficiency estimate of the 169Yb production process, with and without re-activation. METHODS AND MATERIALS A time-dependent thermal neutron transport, isotope transmutation, and decay model was developed. Thermal neutron flux within partitioned sub-volumes of a cylindrical active source was calculated by raytracing through the spatiotemporal dependent isotopic composition throughout the source, accounting for thermal neutron attenuation along each ray. The model was benchmarked, generalized, and applied to a variety of active source dimensions with radii ranging from 0.4 to 1.0 mm, lengths from 2.5 to 10.5 mm, and volumes from 0.31 to 7.85 mm3, at thermal neutron fluxes from 1 × 1014 to 1 × 1015 n cm-2 s-1. The 168Yb-Yb2O3 density was 8.5 g cm-3 with 82% 168Yb-enrichment. As an example, a reference re-activatable 169Yb active source (RRS) constructed of 82%-enriched 168Yb-Yb2O3 precursor was modeled, with 0.6 mm diameter, 10.5 mm length, 3 mm3 volume, 8.5 g cm-3 density, and a thermal neutron activation flux of 4 × 1014 neutrons cm-2 s-1. RESULTS The average clinical 169Yb activity for a 0.99 versus 0.31 mm3 source dropped from 20.1 to 7.5 Ci for a 4 × 1014 n cm-2 s-1 activation flux and from 20.9 to 8.7 Ci for a 1 × 1015 n cm-2 s-1 activation flux. For thermal neutron fluxes ≥2 × 1014 n cm-2 s-1, total precursor and reactor time per clinic-year were maximized at a source volume of 0.99 mm3 and reached a near minimum at 3 mm3. When the spatiotemporal isotopic composition effect was accounted for, average thermal neutron transmission increased over RRS lifetime from 23.6% to 55.9%. A 28% reduction (42.5 days to 30.6 days) in the reactor time needed per clinic-year for the RRS is predicted relative to a model that does not account for spatiotemporal isotopic composition effects. CONCLUSIONS Accounting for spatiotemporal isotopic composition effects within the RRS results in a 28% reduction in the reactor time per clinic-year relative to the case in which such changes are not accounted for. Smaller volume sources had a disadvantage in that average clinical 169Yb activity decreased substantially below 20 Ci for source volumes under 1 mm3. Increasing source volume above 3 mm3 adds little value in precursor and reactor time savings and has a geometric disadvantage.
Collapse
Affiliation(s)
- Ryan T Flynn
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
| | - Blake R Smith
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
| | - Quentin E Adams
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
| | | | - Stephen A Graves
- Department of Radiology, University of Iowa, Iowa City, Iowa, USA
| | | |
Collapse
|
4
|
Hopfensperger KM, Adams QE, Kim Y, Wu X, Xu W, Patwardhan K, Flynn RT. The population percentile allowance method for determining systematic spatial error tolerances for temporary intensity modulated brachytherapy. Med Phys 2023; 50:6469-6478. [PMID: 37643427 PMCID: PMC10592112 DOI: 10.1002/mp.16668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 07/03/2023] [Accepted: 07/18/2023] [Indexed: 08/31/2023] Open
Abstract
BACKGROUND Multiple approaches are under development for delivering temporary intensity modulated brachytherapy (IMBT) using partially shielded applicators wherein the delivered dose distributions are sensitive to spatial uncertainties in both the applicator position and shield orientation, rather than only applicator position as with conventional high-dose-rate brachytherapy (HDR-BT). Sensitivity analyses to spatial uncertainties have been reported as components of publications on these emerging technologies, however, a generalized framework for the rigorous determination of the spatial uncertainty tolerances of dose-volume parameters is needed. PURPOSE To derive and present the population percentile allowance (PPA) method, a generalized mathematical and statistical framework to evaluate the tolerance of temporary IMBT approaches to spatial uncertainties in applicator position and shield orientation. METHODS A mathematical formalism describing geometric applicator position and shield orientation shifts was derived that supports straight and curved applicators and applies to serial and helical rotating shield brachytherapy (RSBT) and direction modulated brachytherapy (DMBT). The PPA method entails defining the percentage of a patient population receiving a given therapy that is, allowed to receive dose-volume errors in the target volume and specified organs at risk of a defined percentage or less, then determining what combinations of applicator position and shield orientation systematic errors would be expected to produce that outcome in the population. The PPA method was applied to the use case of multi-shield helical 169 Yb-based RSBT for cervical cancer, with 45° and 180° shield emission angles. A total of 37 cervical cancer patients were considered in the population, with average (± 1 standard deviation) HR-CTV volumes of 79 cm3 ± 37 cm3 and optimized baseline treatment plans (no spatial uncertainties applied) created for each patient to meet dose-volume requirements of 85 GyEQD2 (equivalent uniform dose in 2 Gy fraction), with D2cc tolerance doses of 90 GyEQD2 , 75 GyEQD2 , and 75 GyEQD2 for bladder, rectum, and sigmoid colon, respectively. RESULTS For the PPA requirement that 90% of cervical cancer patients receiving multi-shield helical RSBT could have a maximum dose-volume uncertainty of 10% for high-risk clinical target volume (HR-CTV) D90 (minimum dose to hottest 90%) and bladder, rectum, and sigmoid colon D2cc (minimum dose to hottest 2 cm3 ), the tolerance systematic applicator position and shield orientation uncertainties were approximately ± 1.0 mm and ± 4.25°, respectively. For ± 1.5 mm and ± 5° systematic applicator position and shield orientation tolerances, 90% of the patients considered would have a maximum dose-volume uncertainty of 12.8% or less. CONCLUSION The PPA method was formalized to determine the temporary IMBT spatial uncertainty tolerances that would be expected to result in an allowed percentage of a population of patients receiving relative dose-volume errors above a defined percentage. Multi-shield, helical 169 Yb-based RSBT for cervical cancer was evaluated and tolerances determined, which, if applied on each treatment fraction, would represent an extreme situation. The PPA method is applicable to a variety of temporary IMBT approaches and can be used to rigorously determine the design parameters for the delivery systems such as mechanical driver motor accuracy, shield angle backlash, applicator rotation, and applicator fixation stability.
Collapse
Affiliation(s)
| | - Quentin E Adams
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
| | - Yusung Kim
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
| | - Xiaodong Wu
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
- Department of Electrical and Computer Engineering, Seamans Center for the Engineering Arts and Sciences, University of Iowa, Iowa City, Iowa, USA
| | - Weiyu Xu
- Department of Electrical and Computer Engineering, Seamans Center for the Engineering Arts and Sciences, University of Iowa, Iowa City, Iowa, USA
| | | | - Ryan T Flynn
- Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA
| |
Collapse
|
5
|
Antaki M, Renaud MA, Morcos M, Seuntjens J, Enger SA. Applying the column generation method to the intensity modulated high dose rate brachytherapy inverse planning problem. Phys Med Biol 2023; 68. [PMID: 36791469 DOI: 10.1088/1361-6560/acbc63] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 02/15/2023] [Indexed: 02/17/2023]
Abstract
Objective.Intensity modulated high dose rate brachytherapy (IMBT) is a rapidly developing application of brachytherapy where anisotropic dose distributions can be produced at each source dwell position. This technique is made possible by placing rotating metallic shields inside brachytherapy needles or catheters. By dynamically directing the radiation towards the tumours and away from the healthy tissues, a more conformal dose distribution can be obtained. The resulting treatment planning involves optimizing dwell position and shield angle (DPSA). The aim of this study was to investigate the column generation method for IMBT treatment plan optimization.Approach.A column generation optimization algorithm was developed to optimize the dwell times and shield angles. A retrospective study was performed on 10 prostate cases using RapidBrachyMCTPS. At every iteration, the plan was optimized with the chosen DPSA which would best improve the cost function that was added to the plan. The optimization process was stopped when the remaining DPSAs would not add value to the plan to limit the plan complexity.Main results.The average number of DPSAs and voxels were 2270 and 7997, respectively. The column generation approach yielded near-optimal treatment plans by using only 11% of available DPSAs on average in ten prostate cases. The coverage and organs at risk constraints passed in all ten cases.Significance.The column generation method produced high-quality deliverable prostate IMBT plans. The treatment plan quality reached a plateau, where adding more DPSAs had a minimal effect on dose volume histogram parameters. The iterative nature of the column generation method allows early termination of the treatment plan creation process as soon as the dosimetric indices from dose volume histogram satisfy the clinical requirements or if their values stabilize.
Collapse
Affiliation(s)
- Majd Antaki
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, H4A 3J1, Canada
| | - Marc-André Renaud
- Polytechnique Montréal, Department of Mathematical and Industrial Engineering, Montreal, Canada
| | - Marc Morcos
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, H4A 3J1, Canada.,Department of Radiation Oncology, Miami Cancer Institute, Miami, FL, United States of America.,Herbert Wertheim College of Medicine, Florida International University, Miami, FL, United States of America
| | - Jan Seuntjens
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, H4A 3J1, Canada
| | - Shirin A Enger
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Quebec, H4A 3J1, Canada.,Research Institute of the McGill University Health Centre, Montreal, Quebec, H3H 2L9, Canada.,Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, Quebec, H3T 1E2, Canada
| |
Collapse
|
6
|
Hadadi A, Ghanavati S. 75Se - A promising alternative to 192Ir for potential use in the skin cancer brachytherapy: A Monte Carlo simulation study using FLUKA code. Appl Radiat Isot 2023; 197:110786. [PMID: 37023694 DOI: 10.1016/j.apradiso.2023.110786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 03/18/2023] [Accepted: 03/21/2023] [Indexed: 03/31/2023]
Abstract
This study aimed to evaluate the possibility of utilizing the HDR 75Se source for skin cancer brachytherapy. In this work, based on the BVH-20 skin applicator, two cup-shaped applicators, without and with the flattening filter, were modeled. To obtain the optimal flattening filter shape, an approach based on the MC simulation in combination with an analytical estimation was used. Then, the dose distributions for 75Se-applicators were generated using MC simulations in water, and their dosimetric characterizations such as flatness, symmetry, and penumbra were evaluated. Furthermore, the radiation leakage in the backside of the applicators was estimated by additional MC simulation. Finally, to evaluate the treatment times, calculations were performed for two 75Se-applicators assuming 5 Gy per fraction. The flatness, symmetry, and penumbra values for the 75Se-applicator without the flattening filter were estimated to be 13.7%, 1.05, and 0.41 cm respectively. The corresponding values for 75Se-applicator with the flattening filter were estimated to be 1.6%, 1.06, and 0.10 cm respectively. The radiation leakage value at a distance of 2 cm from the applicator surface was calculated to be 0.2% and 0.4% for the 75Se-applicator without and with the flattening filter respectively. Our results showed that the treatment time for the 75Se-applicator is comparable with that of the 192Ir-Leipzig applicator. The findings revealed that the dosimetric parameters of the 75Se applicator are comparable with the 192Ir skin applicator. Overall, the 75Se source can be an alternative to 192Ir sources for HDR brachytherapy of skin cancer.
Collapse
|
7
|
Morén B, Antaki M, Famulari G, Morcos M, Larsson T, Enger SA, Tedgren ÅC. Dosimetric impact of a robust optimization approach to mitigate effects from rotational uncertainty in prostate intensity-modulated brachytherapy. Med Phys 2023; 50:1029-1043. [PMID: 36478226 DOI: 10.1002/mp.16134] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 10/17/2022] [Accepted: 11/01/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Intensity-modulated brachytherapy (IMBT) is an emerging technology for cancer treatment, in which radiation sources are shielded to shape the dose distribution. The rotatable shields provide an additional degree of freedom, but also introduce an additional, directional, type of uncertainty, compared to conventional high-dose-rate brachytherapy (HDR BT). PURPOSE We propose and evaluate a robust optimization approach to mitigate the effects of rotational uncertainty in the shields with respect to planning criteria. METHODS A previously suggested prototype for platinum-shielded prostate 169 Yb-based dynamic IMBT is considered. We study a retrospective patient data set (anatomical contours and catheter placement) from two clinics, consisting of six patients that had previously undergone conventional 192 Ir HDR BT treatment. The Monte Carlo-based treatment planning software RapidBrachyMCTPS is used for dose calculations. In our computational experiments, we investigate systematic rotational shield errors of ±10° and ±20°, and the same systematic error is applied to all dwell positions in each scenario. This gives us three scenarios, one nominal and two with errors. The robust optimization approach finds a compromise between the average and worst-case scenario outcomes. RESULTS We compare dose plans obtained from standard models and their robust counterparts. With dwell times obtained from a linear penalty model (LPM), for 10° errors, the dose to urethra ( D 0.1 c c $D_{0.1cc}$ ) and rectum ( D 0.1 c c $D_{0.1cc}$ and D 1 c c $D_{1cc}$ ) increase with up to 5% and 7%, respectively, in the worst-case scenario, while with the robust counterpart, the corresponding increases were 3% and 3%. For all patients and all evaluated criteria, the worst-case scenario outcome with the robust approach had lower deviation compared to the standard model, without compromising target coverage. We also evaluated shield errors up to 20° and while the deviations increased to a large extent with the standard models, the robust models were capable of handling even such large errors. CONCLUSIONS We conclude that robust optimization can be used to mitigate the effects from rotational uncertainty and to ensure the treatment plan quality of IMBT.
Collapse
Affiliation(s)
- Björn Morén
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Majd Antaki
- Department of Oncology, Medical Physics Unit, McGill University, Montreal, QC, Canada
| | - Gabriel Famulari
- Department of Oncology, Medical Physics Unit, McGill University, Montreal, QC, Canada.,Département de Radio-oncologie, Centre Hospitalier de l'Université de Montréal, Montreal, QC, Canada
| | - Marc Morcos
- Department of Oncology, Medical Physics Unit, McGill University, Montreal, QC, Canada
| | - Torbjörn Larsson
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Shirin A Enger
- Department of Oncology, Medical Physics Unit, McGill University, Montreal, QC, Canada.,Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, QC, Canada
| | - Åsa Carlsson Tedgren
- Radiation Physics, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Oncology Pathology, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
8
|
Song WY, Robar JL, Morén B, Larsson T, Carlsson Tedgren Å, Jia X. Emerging technologies in brachytherapy. Phys Med Biol 2021; 66. [PMID: 34710856 DOI: 10.1088/1361-6560/ac344d] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 10/28/2021] [Indexed: 01/15/2023]
Abstract
Brachytherapy is a mature treatment modality. The literature is abundant in terms of review articles and comprehensive books on the latest established as well as evolving clinical practices. The intent of this article is to part ways and look beyond the current state-of-the-art and review emerging technologies that are noteworthy and perhaps may drive the future innovations in the field. There are plenty of candidate topics that deserve a deeper look, of course, but with practical limits in this communicative platform, we explore four topics that perhaps is worthwhile to review in detail at this time. First, intensity modulated brachytherapy (IMBT) is reviewed. The IMBT takes advantage ofanisotropicradiation profile generated through intelligent high-density shielding designs incorporated onto sources and applicators such to achieve high quality plans. Second, emerging applications of 3D printing (i.e. additive manufacturing) in brachytherapy are reviewed. With the advent of 3D printing, interest in this technology in brachytherapy has been immense and translation swift due to their potential to tailor applicators and treatments customizable to each individual patient. This is followed by, in third, innovations in treatment planning concerning catheter placement and dwell times where new modelling approaches, solution algorithms, and technological advances are reviewed. And, fourth and lastly, applications of a new machine learning technique, called deep learning, which has the potential to improve and automate all aspects of brachytherapy workflow, are reviewed. We do not expect that all ideas and innovations reviewed in this article will ultimately reach clinic but, nonetheless, this review provides a decent glimpse of what is to come. It would be exciting to monitor as IMBT, 3D printing, novel optimization algorithms, and deep learning technologies evolve over time and translate into pilot testing and sensibly phased clinical trials, and ultimately make a difference for cancer patients. Today's fancy is tomorrow's reality. The future is bright for brachytherapy.
Collapse
Affiliation(s)
- William Y Song
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, United States of America
| | - James L Robar
- Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Björn Morén
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Torbjörn Larsson
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Åsa Carlsson Tedgren
- Radiation Physics, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Oncology Pathology, Karolinska Institute, Stockholm, Sweden
| | - Xun Jia
- Innovative Technology Of Radiotherapy Computations and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, United States of America
| |
Collapse
|
9
|
Nasser NJ. Applicator for cervical brachytherapy for MRI or CT guided therapy. Tech Innov Patient Support Radiat Oncol 2021; 20:23-27. [PMID: 34765750 PMCID: PMC8571076 DOI: 10.1016/j.tipsro.2021.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 10/21/2021] [Accepted: 10/21/2021] [Indexed: 11/30/2022] Open
Abstract
Cervical applicator for brachytherapy with anchorage similar to intrauterine device. Cervical applicator that can be inserted bedside. Cervical applicator that can be associated with less pain compared to current applicators.
Cervical cancer is the second leading cause of cancer death in women aged 20 to 39 years in the USA. Radiation therapy for cervical cancer in the definitive setting is delivered by combining external beam radiation and brachytherapy. The procedure of cervical brachytherapy could be associated with significant discomfort and pain to the patient. Here we describe a novel cervical applicator, that can be inserted bedside, with local anesthesia only. The device is similar to intrauterine device and vaginal ring used for contraception, albeit with channels for high dose rate brachytherapy.
Collapse
Affiliation(s)
- Nicola J Nasser
- Department of Radiation Oncology, School of Medicine, Maryland Proton Treatment Center, University of Maryland Baltimore, Baltimore, MD 21201, USA.,The Umbilicus Inc., Nonprofit Organization for Preserving Sexual Function of Individuals with Cancer Below the Umbilicus, New York, NY, USA
| |
Collapse
|
10
|
Yan J, Zhu J, Chen K, Yu L, Zhang F. Intra-fractional dosimetric analysis of image-guided intracavitary brachytherapy of cervical cancer. Radiat Oncol 2021; 16:144. [PMID: 34348758 PMCID: PMC8335895 DOI: 10.1186/s13014-021-01870-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 07/25/2021] [Indexed: 11/14/2022] Open
Abstract
Background To assess the intra-fractional dosimetric variations of image-guided brachytherapy of cervical cancer. Methods A total of 38 fractions (9 patients) undergoing brachytherapy for cervical cancer underwent a CT scanning for treatment planning (planning CT) and a Cone-beam CT (CBCT) scanning immediately prior to delivery (pre-delivery CBCT). The variations of volumes as well as the dosimetric impact from treatment planning to delivery (intra-application) were evaluated. The dose volume histogram parameters including volume, D90 of high-risk clinical target volume (HRCTV) and D2cc of organs at risk (OARs) were recorded. Results The relative differences (mean ± 1SD) of the volume and D90 HRCTV across the two scans were − 2.0 ± 3.3% and − 1.2 ± 4.5%, respectively. The variations of D2cc for bladder, rectum, sigmoid and small intestine are − 0.6 ± 17.1%, 9.3 ± 14.6%, 7.2% ± 20.5% and 1.5 ± 12.6%, respectively. Most of them are statistically nonsignificant except the D2cc for rectum, which showed a significant increase (P = 0.001). Using 5% and 10% uncertainty of physical dose for HRCTV at a 6 Gy × 5 high-dose-rate schedule, the possibility of total equivalent doses in 2 Gy fractions (EQD2) lower than 85 Gy is close to 0% and 3%, respectively. Performing similar simulation at 15% and 20% uncertainty of a 4 Gy physical dose for OARs, the possibility of total EQD2 dose exceeding 75 Gy is about 70%. Less than 1% of the total EQD2 of OARs would exceed 80 Gy. Conclusions Average intra-fractional dosimetric variation of HRCTV was small in an interval of less than 1 h, and the possibility of total EQD2 exceeding 85 Gy is higher than 97%. The intra-fractional dosimetric variations of OARs might result in an overdose for OARs in a single fraction or the whole treatment. It is necessary to detect unfavorable anatomical changes by re-imaging and take interventions to minimize applied doses and reduce the risk of complications. Supplementary Information The online version contains supplementary material available at 10.1186/s13014-021-01870-x.
Collapse
Affiliation(s)
- Junfang Yan
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academe of Medical Sciences & Peking Union Medical College, Beijing, 100730, China
| | - Jiawei Zhu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academe of Medical Sciences & Peking Union Medical College, Beijing, 100730, China
| | - Kai Chen
- Department of Radiation Oncology, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, Guangzhou, 510060, Guangdong, China
| | - Lang Yu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academe of Medical Sciences & Peking Union Medical College, Beijing, 100730, China
| | - Fuquan Zhang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academe of Medical Sciences & Peking Union Medical College, Beijing, 100730, China.
| |
Collapse
|
11
|
Morcos M, Viswanathan AN, Enger SA. On the impact of absorbed dose specification, tissue heterogeneities, and applicator heterogeneities on Monte Carlo-based dosimetry of Ir-192, Se-75, and Yb-169 in conventional and intensity-modulated brachytherapy for the treatment of cervical cancer. Med Phys 2021; 48:2604-2613. [PMID: 33619739 DOI: 10.1002/mp.14802] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 01/27/2021] [Accepted: 02/10/2021] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The purpose of this study was to evaluate the impact of dose reporting schemes and tissue/applicator heterogeneities for 192 Ir-, 75 Se-, and 169 Yb-based MRI-guided conventional and intensity-modulated brachytherapy. METHODS AND MATERIALS Treatment plans using a variety of dose reporting and tissue/applicator segmentation schemes were generated for a cohort (n = 10) of cervical cancer patients treated with 192 Ir-based Venezia brachytherapy. Dose calculations were performed using RapidBrachyMCTPS, a Geant4-based research Monte Carlo treatment planning system. Ultimately, five dose calculation scenarios were evaluated: (a) dose to water in water (Dw,w ); (b) Dw,w taking the applicator material into consideration (Dw,wApp ); (c) dose to water in medium (Dw,m ); (d and e) dose to medium in medium with mass densities assigned either nominally per structure (Dm,m (Nom) ) or voxel-by-voxel (Dm,m ). RESULTS Ignoring the plastic Venezia applicator (Dw,wApp ) overestimates Dm,m by up to 1% (average) with high energy source (192 Ir and 75 Se) and up to 2% with 169 Yb. Scoring dose to water (Dw,wApp or Dw,m ) generally overestimates dose and this effect increases with decreasing photon energy. Reporting dose other than Dm,m (or Dm,m Nom ) for 169 Yb-based conventional and intensity-modulated brachytherapy leads to a simultaneous overestimation (up to 4%) of CTVHR D90 and underestimation (up to 2%) of bladder D2cc due to a significant dip in the mass-energy absorption ratios at the depths of nearby targets and OARs. Using a nominal mass-density assignment per structure, rather than a CT-derived voxel-by-voxel assignment for MRI-guided brachytherapy, amounts to a dose error up to 1% for all radionuclides considered. CONCLUSIONS The effects of the considered dose reporting schemes trend correspondingly between conventional and intensity-modulated brachytherapy. In the absence of CT-derived mass densities, MRI-only-based dosimetry can adequately approximate Dm,m by assigning nominal mass densities to structures. Tissue and applicator heterogeneities do not significantly impact dosimetry for 192 Ir and 75 Se, but do for 169 Yb; dose reporting must be explicitly defined since Dw,m and Dw,w may overstate the dosimetric benefits.
Collapse
Affiliation(s)
- Marc Morcos
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, QC, Canada.,Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, USA
| | - Akila N Viswanathan
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, USA
| | - Shirin A Enger
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, QC, Canada.,Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, QC, Canada
| |
Collapse
|