Xin X, Tang B, Wu F, Lang J, Li J, Wang X, Liu M, Zhang Q, Liao X, Yang F, Orlandini LC. Dose tracking assessment for magnetic resonance guided adaptive radiotherapy of rectal cancers. Radiat Oncol 2024; 19:114. [PMID: 39218934 PMCID: PMC11367860 DOI: 10.1186/s13014-024-02508-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Accepted: 08/17/2024] [Indexed: 09/04/2024] Open
Abstract
BACKGROUND Magnetic resonance-guided adaptive radiotherapy (MRgART) at MR-Linac allows for plan optimisation on the MR-based synthetic CT (sCT) images, adjusting the target and organs at risk according to the patient's daily anatomy. Conversely, conventional linac image-guided radiotherapy (IGRT) involves rigid realignment of regions of interest to the daily anatomy, followed by the delivery of the reference computed tomography (CT) plan. This study aims to evaluate the effectiveness of MRgART versus IGRT for rectal cancer patients undergoing short-course radiotherapy, while also assessing the dose accumulation process to support the findings and determine its usefulness in enhancing treatment accuracy. METHODS Nineteen rectal cancer patients treated with a 1.5 Tesla MR-Linac with a prescription dose of 25 Gy (5 Gy x 5) and undergoing daily adapted radiotherapy by plan optimization based on online MR-based sCT images, were included in this retrospective study. For each adapted plan ([Formula: see text]), a second plan ([Formula: see text]) was generated by recalculating the reference CT plan on the daily MR-based sCT images after rigid registration with the reference CT images to simulate the IGRT workflow. Dosimetry of [Formula: see text] and[Formula: see text]was compared for each fraction. Cumulative doses on the first and last fractions were evaluated for both workflows. The dosimetry per single fraction and the cumulative doses were compared using dose-volume histogram parameters. RESULTS Ninety-five fractions delivered with MRgART were compared to corresponding simulated IGRT fractions. All MRgART fractions fulfilled the target clinical requirements. IGRT treatments did not meet the expected target coverage for 63 out of 94 fractions (67.0%), with 13 fractions showing a V95 median point percentage decrease of 2.78% (range, 1.65-4.16%), and 55 fractions exceeding the V107% threshold with a median value of 15.4 cc (range, 6.0-43.8 cc). For the bladder, the median [Formula: see text] values were 18.18 Gy for the adaptive fractions and 19.60 Gy for the IGRT fractions. Similarly the median [Formula: see text] values for the small bowel were 23.40 Gy and 25.69 Gy, respectively. No statistically significant differences were observed in the doses accumulated on the first or last fraction for the adaptive workflow, with results consistent with the single adaptive fractions. In contrast, accumulated doses in the IGRT workflow showed significant variations mitigating the high dose constraint, nevertheless, more than half of the patients still did not meet clinical requirements. CONCLUSIONS MRgART for short-course rectal cancer treatments ensures that the dose delivered matches each fraction of the planned dose and the results are confirmed by the dose accumulation process, which therefore seems redundant. In contrast, IGRT may lead to target dose discrepancies and non-compliance with organs at risk constraints and dose accumulation can still highlight notable dosimetric differences.
Collapse
Affiliation(s)
- Xin Xin
- College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, No.1 East 3 road ErXian bridge, Chengdu, China
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Bin Tang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China.
| | - Fan Wu
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Jinyi Lang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Jie Li
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Xianliang Wang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Min Liu
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Qingxian Zhang
- College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, No.1 East 3 road ErXian bridge, Chengdu, China
| | - Xiongfei Liao
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Feng Yang
- College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, No.1 East 3 road ErXian bridge, Chengdu, China
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| | - Lucia Clara Orlandini
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, No.55, the 4th Section, Chengdu Renmin South Road, Chengdu, China
| |
Collapse
|
2
|
Wang G, Wang Z, Zhang Y, Sun X, Sun Y, Guo Y, Zeng Z, Zhou B, Hu K, Qiu J, Yan J, Zhang F. Daily Online Adaptive Radiation Therapy of Postoperative Endometrial and Cervical Cancer With PTV Margin Reduction to 5 mm: Dosimetric Outcomes, Acute Toxicity, and First Clinical Experience. Adv Radiat Oncol 2024; 9:101510. [PMID: 38826155 PMCID: PMC11140188 DOI: 10.1016/j.adro.2024.101510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 04/02/2024] [Indexed: 06/04/2024] Open
Abstract
Purpose This study evaluated the first clinical implementation of daily iterative cone beam computed tomography (iCBCT)-guided online adaptive radiation therapy (oART) in the postoperative treatment of endometrial and cervical cancer. Methods and Materials Seventeen consecutive patients treated with daily iCBCT-guided oART were enrolled in this prospective study, with a reduced uniform 3-dimensional PTV margin of 5 mm. Treatment plans were designed to deliver 45 or 50.4 Gy in 1.8 Gy daily fractions to PTV. Pre- and posttreatment ultrasound and iCBCT scans were performed to record intrafractional bladder and rectal volume changes. The accuracy of contouring, oART procedure time, dosimetric outcomes, and acute toxicity were evaluated. Results The average time from first iCBCT acquisition to completion of treatment was 22 minutes and 26 seconds. During this period, bladder volume increased by 44 cm3 using iCBCT contouring, whereas rectal volume remained stable (62.9 cm3 pretreatment vs 61.9 cm3 posttreatment). A total of 91.6% of influencers and 88.1% of CTVs required no or minor edits. The adapted plan was selected in all (434) fractions and significantly improved the dosimetry coverage for CTV and PTV, especially the vaginal PTV coverage by nearly 7% (P < .05). The adapted bladder Dmean was 104.61 cGy, and the rectum Dmean was 123.67 cGy, significantly lower than the scheduled plan of 108.24 and 128.19 cGy, respectively. The bone marrow and femur head left and right dosimetry were also improved with adaptation. Grade 2 acute gastrointestinal and genitourinary toxicities were 24% and 0, respectively. There was a grade 3 acute toxicity of decreased white blood cell count in 1 patient. Conclusions Daily oART was associated with favorable dosimetry improvement and low acute toxicity, supporting its safety and efficacy for postoperative treatment of endometrial and cervical cancer. These results need to be validated in a larger prospective randomized controlled cohort.
Collapse
Affiliation(s)
- Guangyu Wang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Zhiqun Wang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Yu Zhang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Xiansong Sun
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Yuliang Sun
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Yuping Guo
- Tumor Hospital affiliated to Xinjiang Medical University, Urumqi, China
| | - Zheng Zeng
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Bing Zhou
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Ke Hu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Jie Qiu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Junfang Yan
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| | - Fuquan Zhang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
- Department of Radiation Oncology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
| |
Collapse
|
3
|
Shimomura A, Wu T, Rusu I, Kishan AU, Tree AC, Solanki AA, Liauw SL. Monitoring Intrafraction Motion of the Prostate During Radiation Therapy: Suggested Practice Points From a Focused Review. Pract Radiat Oncol 2024; 14:146-153. [PMID: 37875222 DOI: 10.1016/j.prro.2023.08.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 08/30/2023] [Accepted: 08/31/2023] [Indexed: 10/26/2023]
Abstract
PURPOSE External beam radiation therapy to the prostate is typically delivered after verification of prostatic position with image guidance. Prostate motion can occur during the delivery of each radiation treatment between the time of localization imaging and completion of treatment. The objective of this work is to review the literature on intrafraction motion (IFM) of the prostate during radiation therapy and offer clinical recommendations on management. METHODS AND MATERIALS A comprehensive literature review was conducted on prostate motion during prostate cancer radiation therapy. Information was organized around 3 key clinical questions, followed by an evidence-based recommendation. RESULTS IFM of the prostate during radiation therapy is typically ≤3 mm and is unlikely to compromise prostate dosimetry to a clinically meaningful degree for men treated in a relatively short treatment duration with planning target volume (PTV) margins of ≥3 to 5 mm. IFM of 5 mm or more has been observed in up to ∼10% of treatment fractions, with limited dosimetric effect related to the infrequency of occurrence and longer fractionation of therapy. IFM can be monitored in continuous or discontinuous fashion with a variety of imaging platforms. Correction of IFM may have the greatest value when tighter PTV margins are desired (such as with stereotactic body radiation therapy or intraprostatic nodule boosting), ultrahypofractionated courses, or when treatment time exceeds several minutes. CONCLUSIONS This focused review summarizes literature and provides practical recommendations regarding IFM in the treatment of prostate cancer with external beam radiation therapy.
Collapse
Affiliation(s)
- Aoi Shimomura
- Department of Radiation and Cellular Oncology, University of Chicago Medicine, Chicago, Illinois
| | - Tianming Wu
- Department of Radiation and Cellular Oncology, University of Chicago Medicine, Chicago, Illinois
| | - Iris Rusu
- Department of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Maywood, Illinois
| | - Amar U Kishan
- Department of Radiation Oncology, University of California, Los Angeles, California
| | - Alison C Tree
- The Royal Marsden NHS Foundation Trust, Sutton, United Kingdom; Division of Radiotherapy and Imaging, Institute of Cancer Research, Sutton, United Kingdom
| | - Abhishek A Solanki
- Department of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Maywood, Illinois
| | - Stanley L Liauw
- Department of Radiation and Cellular Oncology, University of Chicago Medicine, Chicago, Illinois.
| |
Collapse
|
4
|
Nardini M, Meffe G, Galetto M, Boldrini L, Chiloiro G, Romano A, Panza G, Bevacqua A, Turco G, Votta C, Capotosti A, Moretti R, Gambacorta MA, Indovina L, Placidi L. Why we should care about gas pockets in online adaptive MRgRT: a dosimetric evaluation. Front Oncol 2023; 13:1280836. [PMID: 38023178 PMCID: PMC10679396 DOI: 10.3389/fonc.2023.1280836] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 10/27/2023] [Indexed: 12/01/2023] Open
Abstract
Introduction Contouring of gas pockets is a time consuming step in the workflow of adaptive radiotherapy. We would like to better understand which gas pockets electronic densitiy should be used and the dosimetric impact on adaptive MRgRT treatment. Materials and methods 21 CT scans of patients undergoing SBRT were retrospectively evaluated. Anatomical structures were contoured: Gross Tumour Volume (GTV), stomach (ST), small bowel (SB), large bowel (LB), gas pockets (GAS) and gas in each organ respectively STG, SBG, LBG. Average HU in GAS was converted in RED, the obtained value has been named as Gastrointestinal Gas RED (GIGED). Differences of average HU in GAS, STG, SBG and LBG were computed. Three treatment plans were calculated editing the GAS volume RED that was overwritten with: air RED (0.0012), water RED (1.000), GIGED, generating respectively APLAN, WPLAN and the GPLAN. 2-D dose distributions were analyzed by gamma analysis. Parameter called active gas volume (AGV) was calculated as the intersection of GAS with the isodose of 5% of prescription dose. Results Average HU value contained in GAS results to be equal to -620. No significative difference was noted between the average HU of gas in different organ at risk. Value of Gamma Passing Rate (GPR) anticorrelates with the AGV for each plan comparison and the threshold value for GPR to fall below 90% is 41, 60 and 139 cc for WPLANvsAPLAN, GPLANvsAPLAN and WPLANvsGPLAN respectively. Discussions GIGED is the right RED for Gastrointestinal Gas. Novel AGV is a useful parameter to evaluate the effect of gas pocket on dose distribution.
Collapse
Affiliation(s)
- Matteo Nardini
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Guenda Meffe
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Matteo Galetto
- Radiotherapy Department, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Luca Boldrini
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Giuditta Chiloiro
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Angela Romano
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Giulia Panza
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Andrea Bevacqua
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Gabriele Turco
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Claudio Votta
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Amedeo Capotosti
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Roberto Moretti
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Maria Antonietta Gambacorta
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
- Radiotherapy Department, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Luca Indovina
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| | - Lorenzo Placidi
- Fondazione Policlinico Universitario ‘‘A. Gemelli’’ IRCCS, Rome, Italy
| |
Collapse
|
5
|
SHIRATO H. Biomedical advances and future prospects of high-precision three-dimensional radiotherapy and four-dimensional radiotherapy. PROCEEDINGS OF THE JAPAN ACADEMY. SERIES B, PHYSICAL AND BIOLOGICAL SCIENCES 2023; 99:389-426. [PMID: 37821390 PMCID: PMC10749389 DOI: 10.2183/pjab.99.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 09/13/2023] [Indexed: 10/13/2023]
Abstract
Biomedical advances of external-beam radiotherapy (EBRT) with improvements in physical accuracy are reviewed. High-precision (±1 mm) three-dimensional radiotherapy (3DRT) can utilize respective therapeutic open doors in the tumor control probability curve and in the normal tissue complication probability curve instead of the one single therapeutic window in two-dimensional EBRT. High-precision 3DRT achieved higher tumor control and probable survival rates for patients with small peripheral lung and liver cancers. Four-dimensional radiotherapy (4DRT), which can reduce uncertainties in 3DRT due to organ motion by real-time (every 0.1-1 s) tumor-tracking and immediate (0.1-1 s) irradiation, have achieved reduced adverse effects for prostate and pancreatic tumors near the digestive tract and with similar or better tumor control. Particle beam therapy improved tumor control and probable survival for patients with large liver tumors. The clinical outcomes of locally advanced or multiple tumors located near serial-type organs can theoretically be improved further by integrating the 4DRT concept with particle beams.
Collapse
Affiliation(s)
- Hiroki SHIRATO
- Global Center for Biomedical Science and Engineering, Faculty of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| |
Collapse
|
6
|
Chiang CH, Chao TY, Huang MY. Adaptive radiotherapy of locally advanced sigmoid colon cancer with intra‑fractional motion using the MRIdian system: A case report. Oncol Lett 2023; 26:487. [PMID: 37818131 PMCID: PMC10561135 DOI: 10.3892/ol.2023.14074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Accepted: 09/14/2023] [Indexed: 10/12/2023] Open
Abstract
Neoadjuvant chemotherapy, when combined with radiotherapy, serves as an optional treatment for patients with locally advanced sigmoid colon cancer and is usually performed in conjunction with complete mesocolic excision. The substantial movement of surrounding organs in cases of sigmoid colon cancer frequently leads to toxicity in normal tissues. The present report details the case of a 76-year-old man diagnosed with locally advanced sigmoid colon cancer. Initially, treatment using the Tomotherapy Hi-Art system was selected; however, during image guidance from the first to the sixth fractions, the tumor location underwent a marked change, exceeding the range of the planning target volume. Efforts to recapture the image were unsuccessful, leading to a decision to transition the patient to the MRIdian system for daily treatment with online adaptive radiotherapy. The positional variations in the tumor were evident in each treatment using the MRIdian system, with mean shifts of 2.58 cm in the right-left direction, 1.24 cm in the cranial-caudal direction and 0.40 cm in the anterior-posterior direction. The mean time from the entry of the patient to treatment completion was 41 min. Adaptive treatment plans were performed for all 19 fractions, with two treatments repeated due to the tumor moving out of tracking range. Following irradiation using the MRIdian system, the gross tumor volume decreased by 62%. Notably, the patient experienced no side effects during treatment. A CT scan conducted 3 months after radiotherapy revealed a marked reduction in the tumor size, consistent with a partial response, leading to the scheduling of surgery. Following surgery, a CT scan after 6 months revealed no local recurrence in the surgical bed region. The findings in the present case support the feasibility of implementing an adaptive treatment plan using the MRIdian system for locally advanced sigmoid colon cancer in the context of neoadjuvant chemoradiotherapy.
Collapse
Affiliation(s)
- Chen-Han Chiang
- Department of Radiation Oncology, Kaohsiung Medical University Hospital, Kaohsiung 80756, Taiwan, R.O.C
| | - Tzu-Yuan Chao
- Department of Radiation Oncology, Kaohsiung Medical University Hospital, Kaohsiung 80756, Taiwan, R.O.C
| | - Ming-Yii Huang
- Department of Radiation Oncology, Kaohsiung Medical University Hospital, Kaohsiung 80756, Taiwan, R.O.C
- Department of Radiation Oncology, School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung 80756, Taiwan, R.O.C
| |
Collapse
|
7
|
Peng H, Zhang J, Xu N, Zhou Y, Tan H, Ren T. Fan beam CT-guided online adaptive external radiotherapy of uterine cervical cancer: a dosimetric evaluation. BMC Cancer 2023; 23:588. [PMID: 37365516 DOI: 10.1186/s12885-023-11089-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 06/20/2023] [Indexed: 06/28/2023] Open
Abstract
PURPOSE To discuss the dosimetric advantages and reliability of the accurate delivery of online adaptive radiotherapy(online ART) for uterine cervical cancer(UCC). METHODS AND MATERIALS Six UCC patients were enrolled in this study. 95% of the planning target volume (PTV) reached 100% of the prescription dose (50.4 Gy/28fractions/6weeks) was required. The patients were scanned with uRT-Linac 506c KV-FBCT then the target volume (TV) and organs at risk (OARs) were delineated by doctors. The dosimeters designed and obtained a routine plan (Plan0). KV-FBCT was used for image guidance before subsequent fractional treatment. The online ART was processed after registration, which acquired a virtual nonadaptive radiotherapy plan (VPlan) and an adaptive plan (APlan). VPlan was the direct calculation of Plan0 on the fractional image, while APlan required adaptive optimization and calculation. In vivo dose monitoring and three-dimensional dose reconstruction were required during the implementation of APlan. RESULTS The inter-fractional volumes of the bladder and rectum changed greatly among the treatments. These changes influenced the primary gross tumor volume (GTVp) and the position deviation of GTVp and PTV and positively affected the prescription dose coverage of TV. GTVp decreased gradually along with dose accumulation. The Dmax, D98, D95, D50, and D2 of APlan were superior to those of VPlan in target dose distribution. APlan had good conformal index, homogeneity index and target coverage. The rectum V40 and Dmax, bladder V40, the small bowel V40 and Dmax of APlan were better than that of VPlan. The APlan's fractional mean γ passing rate was significantly higher than the international standard and the mean γ passing rate of all cases after the three-dimensional reconstruction was higher than 97.0%. CONCLUSION Online ART in external radiotherapy of UCC significantly improved the dose distribution and can become an ideal technology to achieve individualized precise radiotherapy.
Collapse
Affiliation(s)
- Haibo Peng
- Oncology Department, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China
- Key Clinical Specialty of Sichuan Province (Oncology Department), The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China
- Clinical Medical School, Chengdu Medical College, Chengdu, 610500, China
| | - Jie Zhang
- Oncology Department, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China
- Key Clinical Specialty of Sichuan Province (Oncology Department), The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China
- Clinical Medical School, Chengdu Medical College, Chengdu, 610500, China
| | - Ningyue Xu
- Oncology Department, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China
| | - Yangang Zhou
- Oncology Department, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China
| | - Huigang Tan
- Oncology Department, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China
| | - Tao Ren
- Oncology Department, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China.
- Key Clinical Specialty of Sichuan Province (Oncology Department), The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, China.
- Clinical Medical School, Chengdu Medical College, Chengdu, 610500, China.
| |
Collapse
|
8
|
Shortall J, Vasquez Osorio E, Green A, McWilliam A, Elumalai T, Reeves K, Johnson-Hart C, Beasley W, Hoskin P, Choudhury A, van Herk M. Dose outside of the prostate is associated with improved outcomes for high-risk prostate cancer patients treated with brachytherapy boost. Front Oncol 2023; 13:1200676. [PMID: 37397380 PMCID: PMC10311256 DOI: 10.3389/fonc.2023.1200676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 05/31/2023] [Indexed: 07/04/2023] Open
Abstract
Background One in three high-risk prostate cancer patients treated with radiotherapy recur. Detection of lymph node metastasis and microscopic disease spread using conventional imaging is poor, and many patients are under-treated due to suboptimal seminal vesicle or lymph node irradiation. We use Image Based Data Mining (IBDM) to investigate association between dose distributions, and prognostic variables and biochemical recurrence (BCR) in prostate cancer patients treated with radiotherapy. We further test whether including dose information in risk-stratification models improves performance. Method Planning CTs, dose distributions and clinical information were collected for 612 high-risk prostate cancer patients treated with conformal hypo-fractionated radiotherapy, intensity modulated radiotherapy (IMRT), or IMRT plus a single fraction high dose rate (HDR) brachytherapy boost. Dose distributions (including HDR boost) of all studied patients were mapped to a reference anatomy using the prostate delineations. Regions where dose distributions significantly differed between patients that did and did-not experience BCR were assessed voxel-wise using 1) a binary endpoint of BCR at four-years (dose only) and 2) Cox-IBDM (dose and prognostic variables). Regions where dose was associated with outcome were identified. Cox proportional-hazard models with and without region dose information were produced and the Akaike Information Criterion (AIC) was used to assess model performance. Results No significant regions were observed for patients treated with hypo-fractionated radiotherapy or IMRT. Regions outside the target where higher dose was associated with lower BCR were observed for patients treated with brachytherapy boost. Cox-IBDM revealed that dose response was influenced by age and T-stage. A region at the seminal vesicle tips was identified in binary- and Cox-IBDM. Including the mean dose in this region in a risk-stratification model (hazard ratio=0.84, p=0.005) significantly reduced AIC values (p=0.019), indicating superior performance, compared with prognostic variables only. The region dose was lower in the brachytherapy boost patients compared with the external beam cohorts supporting the occurrence of marginal misses. Conclusion Association was identified between BCR and dose outside of the target region in high-risk prostate cancer patients treated with IMRT plus brachytherapy boost. We show, for the first-time, that the importance of irradiating this region is linked to prognostic variables.
Collapse
Affiliation(s)
- Jane Shortall
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Eliana Vasquez Osorio
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Andrew Green
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Alan McWilliam
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
- Department of Radiotherapy Related Research, The Christie National Health Service (NHS) Foundation Trust, Manchester, United Kingdom
| | - Thriaviyam Elumalai
- Department of Radiotherapy Related Research, The Christie National Health Service (NHS) Foundation Trust, Manchester, United Kingdom
| | - Kimberley Reeves
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Corinne Johnson-Hart
- Department of Radiotherapy Related Research, The Christie National Health Service (NHS) Foundation Trust, Manchester, United Kingdom
| | - William Beasley
- Department of Radiotherapy Related Research, The Christie National Health Service (NHS) Foundation Trust, Manchester, United Kingdom
| | - Peter Hoskin
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
- Department of Radiotherapy Related Research, The Christie National Health Service (NHS) Foundation Trust, Manchester, United Kingdom
| | - Ananya Choudhury
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
- Department of Radiotherapy Related Research, The Christie National Health Service (NHS) Foundation Trust, Manchester, United Kingdom
| | - Marcel van Herk
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| |
Collapse
|
9
|
Higuchi D, Ono T, Kakino R, Aizawa R, Nakayasu N, Ito H, Sakamoto T. Evaluation of internal margins for prostate for step and shoot intensity-modulated radiation therapy and volumetric modulated arc therapy using different margin formulas. J Appl Clin Med Phys 2022; 23:e13707. [PMID: 35719051 PMCID: PMC9512338 DOI: 10.1002/acm2.13707] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 05/24/2022] [Accepted: 06/08/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE This feasibility study evaluated the intra-fractional prostate motion using an ultrasound image-guided system during step and shoot intensity-modulated radiation therapy (SS-IMRT) and volumetric modulated arc therapy (VMAT). Moreover, the internal margins (IMs) using different margin formulas were calculated. METHODS Fourteen consecutive patients with prostate cancer who underwent SS-IMRT (n = 5) or VMAT (n = 9) between March 2019 and April 2020 were considered. The intra-fractional prostate motion was observed in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The displacement of the prostate was defined as the displacement from the initial position at the scanning start time, which was evaluated using the mean ± standard deviation (SD). IMs were calculated using the van Herk and restricted maximum likelihood (REML) formulas for SS-IMRT and VMAT. RESULTS For SS-IMRT, the maximum displacements of the prostate motion were 0.17 ± 0.18, 0.56 ± 0.86, and 0.18 ± 0.59 mm in the SI, AP, and LR directions, respectively. For VMAT, the maximum displacements of the prostate motion were 0.19 ± 0.64, 0.22 ± 0.35, and 0.14 ± 0.37 mm in the SI, AP, and LR directions, respectively. The IMs obtained for SS-IMRT and VMAT were within 2.3 mm and 1.2 mm using the van Herk formula and within 1.2 mm and 0.8 mm using the REML formula. CONCLUSIONS This feasibility study confirmed that intra-fractional prostate motion was observed with SS-IMRT and VMAT using different margin formulas. The IMs should be determined according to each irradiation technique using the REML margin.
Collapse
Affiliation(s)
- Daiki Higuchi
- Department of Radiology, Kyoto Katsura Hospital, Kyoto, Japan
| | - Tomohiro Ono
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Ryo Kakino
- Kansai BNCT Medical Center, Osaka Medical and Pharmaceutical University, Osaka, Japan
| | - Rihito Aizawa
- Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Naoki Nakayasu
- Department of Radiology, Kyoto Katsura Hospital, Kyoto, Japan
| | - Hitoshi Ito
- Department of Radiation Oncology, Kyoto Katsura Hospital, Kyoto, Japan
| | - Takashi Sakamoto
- Department of Radiation Oncology, Kyoto Katsura Hospital, Kyoto, Japan
| |
Collapse
|
10
|
Dosimetric Effects of Air Cavities for MRI-Guided Online Adaptive Radiation Therapy (MRgART) of Prostate Bed after Radical Prostatectomy. J Clin Med 2022; 11:jcm11020364. [PMID: 35054061 PMCID: PMC8780446 DOI: 10.3390/jcm11020364] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 01/08/2022] [Accepted: 01/10/2022] [Indexed: 02/06/2023] Open
Abstract
PURPOSE To evaluate dosimetric impact of air cavities and their corresponding electron density correction for 0.35 tesla (T) Magnetic Resonance-guided Online Adaptive Radiation Therapy (MRgART) of prostate bed patients. METHODS Three 0.35 T MRgRT plans (anterior-posterior (AP) beam, AP-PA beams, and clinical intensity modulated radiation therapy (IMRT)) were generated on a prostate bed patient's (Patient A) planning computed tomography (CT) with artificial rectal air cavities of various sizes (0-3 cm, 0.5 cm increments). Furthermore, two 0.35 T MRgART plans ('Deformed' and 'Override') were generated on a prostate bed patient's (Patient B) daily magnetic resonance image (MRI) with artificial rectal air cavities of various sizes (0-3 cm, 0.5 cm increments) and on five prostate bed patient's (Patient 1-5) daily MRIs (2 MRIs: Fraction A and B) with real air cavities. For each MRgART plan, daily MRI electron density map was obtained by deformable registration with simulation CT. In the 'Deformed' plan, a clinical IMRT plan is calculated on the daily MRI with electron density map obtained from deformable registration only. In the 'Override' plan, daily MRI and simulation CT air cavities are manually corrected and bulk assigned air and water density on the registered electron density map, respectively. Afterwards, the clinical IMRT plan is calculated. RESULTS For the MRgRT plans, AP and AP-PA plans' rectum/rectal wall max dose increased with increasing air cavity size, where the 3 cm air cavity resulted in a 20%/17% and 13%/13% increase, relative to no air cavity, respectively. Clinical IMRT plan was robust to air cavity size, where dose change remained less than 1%. For the MRgART plans, daily MRI electron density maps, obtained from deformable registration with simulation CT, was unable to accurately produce electron densities reflecting the air cavities. However, for the artificial daily MRI air cavities, dosimetric change between 'Deformed' and 'Override' plan was small (<4%). Similarly, for the real daily MRI air cavities, clinical constraint changes between 'Deformed' and 'Override' plan was negligible and did not lead to change in clinical decision for adaptive planning except for two fractions. In these fractions, the 'Override' plan indicated that the bladder max dose and rectum V35.7 exceeded the constraint, while the 'Deformed' plan showed acceptable dose, although the absolute difference was only 0.3 Gy and 0.03 cc, respectively. CONCLUSION Clinical 0.35 T IMRT prostate bed plans are dosimetrically robust to air cavities. MRgART air cavity electron density correction shows clinically insignificant change and is not warranted on low-field systems.
Collapse
|