1
|
Longitudinally Heterogeneous Tumor Dose Optimizes Proton Broadbeam, Interlaced Minibeam, and FLASH Therapy. Cancers (Basel) 2022; 14:cancers14205162. [PMID: 36291946 PMCID: PMC9601234 DOI: 10.3390/cancers14205162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/09/2022] [Accepted: 10/17/2022] [Indexed: 11/21/2022] Open
Abstract
Simple Summary The aim of any kind of external radiation therapy is to control a tumor with the highest possible probability of the lowest possible side effects. Here, we study further opportunities of reducing the side effects of proton therapy by applying longitudinally heterogeneous dose distributions in the tumor respecting the delivery of a minimum prescribed dose. In our simulations, the longitudinally heterogeneous dose distributions show a reduced dose in the healthy tissue already in the case of proton broadbeam irradiations, but a much higher (calculated) mean cell survival in the case of proton minibeam irradiation. This demonstrates its potential to substantially reduce side effects at a simultaneously higher tumor control probability, opening new opportunities of easier application when striving for high dose-rate applications of proton beams (>~10 Gy/s), in order to additionally profit from the so-called FLASH effects. Abstract The prerequisite of any radiation therapy modality (X-ray, electron, proton, and heavy ion) is meant to meet at least a minimum prescribed dose at any location in the tumor for the best tumor control. In addition, there is also an upper dose limit within the tumor according to the International Commission on Radiation Units (ICRU) recommendations in order to spare healthy tissue as well as possible. However, healthy tissue may profit from the lower side effects when waving this upper dose limit and allowing a larger heterogeneous dose deposition in the tumor, but maintaining the prescribed minimum dose level, particularly in proton minibeam therapy. Methods: Three different longitudinally heterogeneous proton irradiation modes and a standard spread-out Bragg peak (SOBP) irradiation mode are simulated for their depth-dose curves under the constraint of maintaining a minimum prescribed dose anywhere in the tumor region. Symmetric dose distributions of two opposing directions are overlaid in a 25 cm-thick water phantom containing a 5 cm-thick tumor region. Interlaced planar minibeam dose distributions are compared to those of a broadbeam using the same longitudinal dose profiles. Results and Conclusion: All longitudinally heterogeneous proton irradiation modes show a dose reduction in the healthy tissue compared to the common SOBP mode in the case of broad proton beams. The proton minibeam cases show eventually a much larger mean cell survival and thus a further reduced equivalent uniform dose (EUD) in the healthy tissue than any broadbeam case. In fact, the irradiation mode using only one proton energy from each side shows better sparing capabilities in the healthy tissue than the common spread-out Bragg peak irradiation mode with the option of a better dose fall-off at the tumor edges and an easier technical realization, particularly in view of proton minibeam irradiation at ultra-high dose rates larger than ~10 Gy/s (so-called FLASH irradiation modes).
Collapse
|
2
|
Schneider T, Fernandez-Palomo C, Bertho A, Fazzari J, Iturri L, Martin OA, Trappetti V, Djonov V, Prezado Y. Combining FLASH and spatially fractionated radiation therapy: The best of both worlds. Radiother Oncol 2022; 175:169-177. [PMID: 35952978 DOI: 10.1016/j.radonc.2022.08.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 07/23/2022] [Accepted: 08/03/2022] [Indexed: 11/16/2022]
Abstract
FLASH radiotherapy (FLASH-RT) and spatially fractionated radiation therapy (SFRT) are two new therapeutical strategies that use non-standard dose delivery methods to reduce normal tissue toxicity and increase the therapeutic index. Although likely based on different mechanisms, both FLASH-RT and SFRT have shown to elicit radiobiological effects that significantly differ from those induced by conventional radiotherapy. With the therapeutic potential having been established separately for each technique, the combination of FLASH-RT and SFRT could therefore represent a winning alliance. In this review, we discuss the state of the art, advantages and current limitations, potential synergies, and where a combination of these two techniques could be implemented today or in the near future.
Collapse
Affiliation(s)
- Tim Schneider
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France; Université Paris-Saclay, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France
| | | | - Annaïg Bertho
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France; Université Paris-Saclay, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France
| | - Jennifer Fazzari
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
| | - Lorea Iturri
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France; Université Paris-Saclay, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France
| | - Olga A Martin
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland; Division of Radiation Oncology, Peter MacCallum Cancer Centre, 305 Grattan St, Melbourne, VIC 3000, Australia; University of Melbourne, Parkville, VIC 3010, Australia
| | - Verdiana Trappetti
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
| | - Valentin Djonov
- Institute of Anatomy, University of Bern, Baltzerstrasse 2, 3012 Bern, Switzerland
| | - Yolanda Prezado
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France; Université Paris-Saclay, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, 91400 Orsay, France.
| |
Collapse
|
3
|
Technical aspects of proton minibeam radiation therapy: Minibeam generation and delivery. Phys Med 2022; 100:64-71. [PMID: 35750002 DOI: 10.1016/j.ejmp.2022.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 06/02/2022] [Accepted: 06/13/2022] [Indexed: 11/23/2022] Open
Abstract
Proton minibeam radiation therapy (pMBRT) is a novel therapeutic strategy that combines the normal tissue sparing of sub-millimetric, spatially fractionated beams with the improved ballistics of protons. This may allow a safe dose escalation in the tumour and has already proven to provide a remarkable increase of the therapeutic index for high-grade gliomas in animal experiments. One of the main challenges in pMBRT concerns the generation of minibeams and the implementation in a clinical environment. This article reviews the different approaches for generating minibeams, using mechanical collimators and focussing magnets, and discusses the technical aspects of the implementation and delivery of pMBRT.
Collapse
|
4
|
Dose Profile Modulation of Proton Minibeam for Clinical Application. Cancers (Basel) 2022; 14:cancers14122888. [PMID: 35740553 PMCID: PMC9221247 DOI: 10.3390/cancers14122888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/03/2022] [Accepted: 06/07/2022] [Indexed: 01/25/2023] Open
Abstract
Simple Summary Proton minibeam radiation therapy (pMBRT) using multislit collimator (MSC) and scatterers has been proposed to spare healthy tissues and organs on the beam path and beyond the Bragg peak. An MSC that was much thicker than the maximum range of the proton beam could provide a sufficiently high peak-to-valley dose ratio at the patient’s skin, and the scatterers could actively convert the spatially fractionated proton beam to a uniform and broad beam in tumors by changing their thickness. The combination of the MSC and the scatterers can be a good solution for implementing pMBRT in clinical proton therapy facilities. Abstract The feasibility of proton minibeam radiation therapy (pMBRT) using a multislit collimator (MSC) and a scattering device was evaluated for clinical use at a clinical proton therapy facility. We fabricated, through Monte Carlo (MC) simulations, not only an MSC with a high peak-to-valley dose ratio (PVDR) at the entrance of the proton beam, to prevent radiation toxicity, but also a scattering device to modulate the PVDR in depth. The slit width and center-to-center distance of the diverging MSC were 2.5 mm and 5.0 mm at the large end, respectively, and its thickness and available field size were 100 mm and 76 × 77.5 mm2, respectively. Spatially fractionated dose distributions were measured at various depths using radiochromic EBT3 films and also tested on bacterial cells. MC simulation showed that the thicker the MSC, the higher the PVDR at the phantom surface. Dosimetric evaluations showed that lateral dose profiles varied according to the scatterer’s thickness, and the depths satisfying PVDR = 1.1 moved toward the surface as their thickness increased. The response of the bacterial cells to the proton minibeams’ depth was also established, in a manner similar to the dosimetric pattern. Conclusively, these results strongly suggest that pMBRT can be implemented in clinical centers by using MSC and scatterers.
Collapse
|
5
|
McAuley GA, Lim CJ, Teran AV, Slater JD, Wroe AJ. Monte Carlo evaluation of high-gradient magnetically focused planar proton minibeams in a passive nozzle. Phys Med Biol 2022; 67. [PMID: 35421853 DOI: 10.1088/1361-6560/ac678b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 04/14/2022] [Indexed: 11/12/2022]
Abstract
Objective. To investigate the potential of using a single quadrupole magnet with a high magnetic field gradient to create planar minibeams suitable for clinical applications of proton minibeam radiation therapy.Approach. We performed Monte Carlo simulations involving single quadrupole Halbach cylinders in a passively scattered nozzle in clinical use for proton therapy. Pencil beams produced by the nozzle of 10-15 mm initial diameters and particle range of ∼10-20 cm in water were focused by magnets with field gradients of 225-350 T m-1and cylinder lengths of 80-110 mm to produce very narrow elongated (planar) beamlets. The corresponding dose distributions were scored in a water phantom. Composite minibeam dose distributions composed from three beamlets were created by laterally shifting copies of the single beamlet distribution to either side of a central beamlet. Modulated beamlets (with 18-30 mm nominal central SOBP) and corresponding composite dose distributions were created in a similar manner. Collimated minibeams were also compared with beams focused using one magnet/particle range combination.Main results. The focusing magnets produced planar beamlets with minimum lateral FWHM of ∼1.1-1.6 mm. Dose distributions composed from three unmodulated beamlets showed a high degree of proximal spatial fractionation and a homogeneous target dose. Maximal peak-to-valley dose ratios (PVDR) for the unmodulated beams ranged from 32 to 324, and composite modulated beam showed maximal PVDR ranging from 32 to 102 and SOBPs with good target dose coverage.Significance.Advantages of the high-gradient magnets include the ability to focus beams with phase space parameters that reflect beams in operation today, and post-waist particle divergence allowing larger beamlet separations and thus larger PVDR. Our results suggest that high gradient quadrupole magnets could be useful to focus beams of moderate emittance in clinical proton therapy.
Collapse
Affiliation(s)
- Grant A McAuley
- Department of Radiation Medicine, Loma Linda University, Loma Linda CA, United States of America
| | - Crystal J Lim
- School of Medicine, Loma Linda University, Loma Linda, CA United States of America
| | - Anthony V Teran
- Department of Radiation Medicine, Loma Linda University, Loma Linda CA, United States of America.,Orange County CyberKnife and Radiation Oncology Center, Fountain Valley, CA, United States of America
| | - Jerry D Slater
- Department of Radiation Medicine, Loma Linda University, Loma Linda CA, United States of America
| | - Andrew J Wroe
- School of Medicine, Loma Linda University, Loma Linda, CA United States of America.,Department of Radiation Oncology, Miami Cancer Institute, Miami, FL, United States of America.,Herbert Wertheim College of Medicine, Florida International University, Miami, Florida, United States of America
| |
Collapse
|
6
|
Mayerhofer M, Mitteneder J, Dollinger G. A 3D printed pure copper drift tube linac prototype. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:023304. [PMID: 35232128 DOI: 10.1063/5.0068494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 02/01/2022] [Indexed: 06/14/2023]
Abstract
Radio frequency cavities are among the most challenging and costly components of an accelerator facility. They are usually manufactured in individual parts, which are then joined by complex processes, e.g., several brazing steps. 3D printing has become an alternative to these conventional manufacturing methods due to higher cost efficiency, freedom in design, and recent achievement of high print quality for pure copper. A fully functional 3 GHz drift tube linac (DTL) prototype was 3D printed in one piece, made from pure copper by selective laser melting (SLM). To achieve a higher surface quality, the DTL geometry was optimized for the SLM process. The DTL design is related to the design of the DTL part of the side-coupled DTL modules used in linac-based proton therapy facilities. The quality factor (8750) and the shunt impedance per unit length (102mΩm) of the printed prototype are already comparable to traditionally manufactured DTL structures and can be further enhanced by surface treatments.
Collapse
Affiliation(s)
- M Mayerhofer
- Institute for Applied Physics and Measurement Technology, Bundeswehr University Munich, 85577 Neubiberg, Bavaria, Germany
| | - J Mitteneder
- Institute for Applied Physics and Measurement Technology, Bundeswehr University Munich, 85577 Neubiberg, Bavaria, Germany
| | - G Dollinger
- Institute for Applied Physics and Measurement Technology, Bundeswehr University Munich, 85577 Neubiberg, Bavaria, Germany
| |
Collapse
|
7
|
Mayerhofer M, Bergmaier A, Datzmann G, Hagn H, Helm R, Mitteneder J, Schubert R, Picardi L, Nenzi P, Ronsivalle C, Wirth HF, Dollinger G. Concept and performance evaluation of two 3 GHz buncher units optimizing the dose rate of a novel preclinical proton minibeam irradiation facility. PLoS One 2021; 16:e0258477. [PMID: 34634079 PMCID: PMC8504737 DOI: 10.1371/journal.pone.0258477] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 09/28/2021] [Indexed: 11/18/2022] Open
Abstract
To demonstrate the large potential of proton minibeam radiotherapy (pMBRT) as a new method to treat tumor diseases, a preclinical proton minibeam radiation facility was designed. It is based on a tandem Van-de-Graaff accelerator providing a 16 MeV proton beam and a 3 GHz linac post-accelerator (designs: AVO-ADAM S.A, Geneva, Switzerland and ENEA, Frascati, Italy). To enhance the transmission of the tandem beam through the post-accelerator by a factor of 3, two drift tube buncher units were designed and constructed: A brazed 5-gap structure (adapted SCDTL tank of the TOP-IMPLART project (ENEA)) and a non-brazed low budget 4-gap structure. Both are made of copper. The performance of the two differently manufactured units was evaluated using a 16 MeV tandem accelerator beam and a Q3D magnetic spectrograph. Both buncher units achieve the required summed voltage amplitude of 42 kV and amplitude stability at a power feed of less than 800 W.
Collapse
Affiliation(s)
- Michael Mayerhofer
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| | - Andreas Bergmaier
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| | - Gerd Datzmann
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| | - Hermann Hagn
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| | - Ricardo Helm
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| | - Johannes Mitteneder
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| | - Ralf Schubert
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| | | | | | | | - Hans-Friedrich Wirth
- Ludwig-Maximilians-Universität München, Fakultät für Physik, München, Bavaria, Germany
| | - Günther Dollinger
- Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik (LRT2), Neubiberg, Bavaria, Germany
| |
Collapse
|
8
|
Conceptual Design of a Novel Nozzle Combined with a Clinical Proton Linac for Magnetically Focussed Minibeams. Cancers (Basel) 2021; 13:cancers13184657. [PMID: 34572884 PMCID: PMC8467416 DOI: 10.3390/cancers13184657] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 09/09/2021] [Accepted: 09/14/2021] [Indexed: 11/23/2022] Open
Abstract
Simple Summary Proton minibeam radiation therapy (pMBRT) is a novel therapeutic strategy that combines the tissue sparing potential of submillimetric, spatially fractionated beams (minibeams) with the improved ballistics of protons to enhance the tolerance of normal tissue and allow a dose escalation in the tumour. This approach could allow a more effective treatment of radioresistant tumours and has already shown excellent results for rat gliomas. To exploit the full potential of pMBRT, it should be delivered using magnetically focussed and scanned minibeams. However, such an implementation has not yet been demonstrated at clinically relevant beam energies. In this work, we therefore present a new design combining our recently developed minibeam nozzle with the first clinical proton linear accelerator. We show the suitability of this combination for the generation of magnetically focussed and scanned minibeams with clinically relevant parameters as well as for the delivery of conventional pencil beam scanning techniques. Abstract (1) Background: Proton minibeam radiation therapy (pMBRT) is a novel therapeutic approach with the potential to significantly increase normal tissue sparing while providing tumour control equivalent or superior to standard proton therapy. For reasons of efficiency, flexibility and minibeam quality, the optimal implementation of pMBRT should use magnetically focussed minibeams which, however, could not yet be generated in a clinical environment. In this study, we evaluated our recently proposed minibeam nozzle together with a new clinical proton linac as a potential implementation. (2) Methods: Monte Carlo simulations were performed to determine under which conditions minibeams can be generated and to evaluate the robustness against focussing magnet errors. Moreover, an example of conventional pencil beam scanning irradiation was simulated. (3) Results: Excellent minibeam sizes between 0.6 and 0.9 mm full width at half maximum could be obtained and a good tolerance to errors was observed. Furthermore, the delivery of a 10 cm × 10 cm field with pencil beams was demonstrated. (4) Conclusion: The combination of the new proton linac and minibeam nozzle could represent an optimal implementation of pMBRT by allowing the generation of magnetically focussed minibeams with clinically relevant parameters. It could furthermore be used for conventional pencil beam scanning.
Collapse
|
9
|
Vidal M, Moignier C, Patriarca A, Sotiropoulos M, Schneider T, De Marzi L. Future technological developments in proton therapy - A predicted technological breakthrough. Cancer Radiother 2021; 25:554-564. [PMID: 34272182 DOI: 10.1016/j.canrad.2021.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 06/18/2021] [Indexed: 12/13/2022]
Abstract
In the current spectrum of cancer treatments, despite high costs, a lack of robust evidence based on clinical outcomes or technical and radiobiological uncertainties, particle therapy and in particular proton therapy (PT) is rapidly growing. Despite proton therapy being more than fifty years old (first proposed by Wilson in 1946) and more than 220,000 patients having been treated with in 2020, many technological challenges remain and numerous new technical developments that must be integrated into existing systems. This article presents an overview of on-going technical developments and innovations that we felt were most important today, as well as those that have the potential to significantly shape the future of proton therapy. Indeed, efforts have been done continuously to improve the efficiency of a PT system, in terms of cost, technology and delivery technics, and a number of different developments pursued in the accelerator field will first be presented. Significant developments are also underway in terms of transport and spatial resolution achievable with pencil beam scanning, or conformation of the dose to the target: we will therefore discuss beam focusing and collimation issues which are important parameters for the development of these techniques, as well as proton arc therapy. State of the art and alternative approaches to adaptive PT and the future of adaptive PT will finally be reviewed. Through these overviews, we will finally see how advances in these different areas will allow the potential for robust dose shaping in proton therapy to be maximised, probably foreshadowing a future era of maturity for the PT technique.
Collapse
Affiliation(s)
- M Vidal
- Centre Antoine-Lacassagne, Fédération Claude Lalanne, 227, avenue de la Lanterne, 06200 Nice, France
| | - C Moignier
- Centre François Baclesse, Department of Medical Physics, Centre de protonthérapie de Normandie, 14000 Caen, France
| | - A Patriarca
- Institut Curie, PSL Research University, Radiation oncology department, Centre de protonthérapie d'Orsay, Campus universitaire, bâtiment 101, 91898 Orsay, France
| | - M Sotiropoulos
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation radiobiologie et cancer, 91400 Orsay, France
| | - T Schneider
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation radiobiologie et cancer, 91400 Orsay, France
| | - L De Marzi
- Institut Curie, PSL Research University, Radiation oncology department, Centre de protonthérapie d'Orsay, Campus universitaire, bâtiment 101, 91898 Orsay, France; Institut Curie, PSL Research University, University Paris Saclay, Inserm LITO, Campus universitaire, 91898 Orsay, France.
| |
Collapse
|