1
|
Iramina H, Tsuneda M, Okamoto H, Kadoya N, Mukumoto N, Toyota M, Fukunaga J, Fujita Y, Tohyama N, Onishi H, Nakamura M. Multi-institutional questionnaire-based survey on online adaptive radiotherapy performed using commercial systems in Japan in 2023. Radiol Phys Technol 2024; 17:581-595. [PMID: 39028438 DOI: 10.1007/s12194-024-00828-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 07/12/2024] [Accepted: 07/13/2024] [Indexed: 07/20/2024]
Abstract
In this study, we aimed to conduct a survey on the current clinical practice of, staffing for, commissioning of, and staff training for online adaptive radiotherapy (oART) in the institutions that installed commercial oART systems in Japan, and to share the information with institutions that will implement oART systems in future. A web-based questionnaire, containing 107 questions, was distributed to nine institutions in Japan. Data were collected from November to December 2023. Three institutions each with the MRIdian (ViewRay, Oakwood Village, OH, USA), Unity (Elekta AB, Stockholm, Sweden), and Ethos (Varian Medical Systems, Palo Alto, CA, USA) systems completed the questionnaire. One institution (MRIdian) had not performed oART by the response deadline. Each institution had installed only one oART system. Hypofractionation, and moderate hypofractionation or conventional fractionation were employed in the MRIdian/Unity and Ethos systems, respectively. The elapsed time for the oART process was faster with the Ethos than with the other systems. All institutions added additional staff for oART. Commissioning periods differed among the oART systems owing to provision of beam data from the vendors. Chambers used during commissioning measurements differed among the institutions. Institutional training was provided by all nine institutions. To the best of our knowledge, this was the first survey about oART performed using commercial systems in Japan. We believe that this study will provide useful information to institutions that installed, are installing, or are planning to install oART systems.
Collapse
Affiliation(s)
- Hiraku Iramina
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-Cho, Shogoin, Sakyo-Ku, Kyoto-Shi, Kyoto, 606-8507, Japan
| | - Masato Tsuneda
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Department of Radiation Oncology, MR Linac ART Division, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-Ku, Chiba-Shi, Chiba, 260-8670, Japan
| | - Hiroyuki Okamoto
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-Ku, Tokyo, 104-0045, Japan
| | - Noriyuki Kadoya
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-Machi, Aoba-Ku, Sendai-Shi, Miyagi, 980-8574, Japan
| | - Nobutaka Mukumoto
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Department of Radiation Oncology, Graduate School of Medicine, Osaka Metropolitan University, 1-4-3 Asahi-Machi, Abeno-Ku, Osaka-Shi, Osaka, 545-8585, Japan
| | - Masahiko Toyota
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Division of Radiology, Department of Clinical Technology, Kagoshima University Hospital, 8-35-1 Sakuragaoka, Kagoshima-Shi, Kagoshima, 890-8520, Japan
| | - Junichi Fukunaga
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-Ku, Fukuoka-Shi, Fukuoka, 812-8582, Japan
| | - Yukio Fujita
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan
- Department of Radiation Oncology, MR Linac ART Division, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-Ku, Chiba-Shi, Chiba, 260-8670, Japan
- Department of Radiological Sciences, Komazawa University, 1-23-1 Komazawa, Setagaya-Ku, Tokyo, 154-8525, Japan
| | - Naoki Tohyama
- Department of Radiological Sciences, Komazawa University, 1-23-1 Komazawa, Setagaya-Ku, Tokyo, 154-8525, Japan
| | - Hiroshi Onishi
- Department of Radiology, University of Yamanashi, 1110 Shimokato, Chuo-Shi, Yamanashi, 409-3898, Japan
| | - Mitsuhiro Nakamura
- Adaptive Radiotherapy Working Group (ART-WG), QA/QC Committee, Japan Society of Medical Physics, Tokyo, Japan.
- Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, 53 Kawahara-Cho, Shogoin, Sakyo-Ku, Kyoto-Shi, Kyoto, 606-8507, Japan.
| |
Collapse
|