Fukuda A, Ichikawa N, Hayashi T, Hirosawa A, Matsubara K. Half-value layer measurements using solid-state detectors and single-rotation technique with lead apertures in spiral computed tomography with and without a tin filter. Radiol Phys Technol 2024; 17:207-218. [PMID: 38127219 DOI: 10.1007/s12194-023-00767-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/08/2023] [Accepted: 11/27/2023] [Indexed: 12/23/2023]
Abstract
Solid-state detectors (SSDs) may be used along with a lead collimator for half-value layer (HVL) measurement using computed tomography (CT) with or without a tin filter. We aimed to compare HVL measurements obtained using three SSDs (AGMS-DM+ , X2 R/F sensor, and Black Piranha) with those obtained using the single-rotation technique with lead apertures (SRTLA). HVL measurements were performed using spiral CT at tube voltages of 70-140 kV without a tin filter and 100-140 kV (Sn 100-140 kV) with a tin filter in increments of 10 kV. For SRTLA, a 0.6-cc ionization chamber was suspended at the isocenter to measure the free-in-air kerma rate (K ˙ air ) values. Five apertures were made on the gantry cover using lead sheets, and four aluminum plates were placed on these apertures. HVLs in SRTLA were obtained fromK ˙ air decline curves. Subsequently, SSDs inserted into the lead collimator were placed on the gantry cover and used to measure HVLs. Maximum HVL differences of AGMS-DM+ , X2 R/F sensor, and Black Piranha with respect to SRTLA without/with a tin filter were - 0.09/0.6 (only two Sn 100-110 kV) mm, - 0.50/ - 0.6 mm, and - 0.17/(no data available) mm, respectively. These values were within the specification limit. SSDs inserted into the lead collimator could be used to measure HVL using spiral CT without a tin filter. HVLs could be measured with a tin filter using only the X2 R/F sensor, and further improvement of its calibration accuracy with respect to other SSDs is warranted.
Collapse
Affiliation(s)
- Atsushi Fukuda
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima, Fukushima, 960-1295, Japan.
| | - Nao Ichikawa
- Department of Radiological Technology, Faculty of Health Science, Kobe Tokiwa University, 2-6-2 Otani-cho, Kobe, Hyogo, 653-0838, Japan
| | - Takuma Hayashi
- Department of Radiation Oncology, Shiga General Hospital, 5-4-30 Moriyama, Moriyama, Shiga, 524-8524, Japan
| | - Ayaka Hirosawa
- Department of Medical Technology, Toyama Prefectural Central Hospital, 2-2-78 Nishinagae, Toyama, 930-8550, Japan
| | - Kosuke Matsubara
- Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
| |
Collapse
|
2
|
Sawall S, Maier J, Sen S, Gehrig H, Kim TS, Schlemmer HP, Schönberg SO, Kachelrieß M, Rütters M. Dental imaging in clinical photon-counting CT at a quarter of DVT dose. J Dent 2024; 142:104859. [PMID: 38272436 DOI: 10.1016/j.jdent.2024.104859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/16/2024] [Accepted: 01/22/2024] [Indexed: 01/27/2024] Open
Abstract
OBJECTIVE To investigate the image quality of a low-dose dental imaging protocol in the first clinical photon-counting computed tomography (PCCT) system in comparison to a normal-dose acquisition in a digital volume tomography (DVT) system. MATERIALS AND METHODS Clinical PCCT systems offer an increased spatial resolution compared to previous generations of clinical systems. Their spatial resolution is in the order of dental DVT systems. Resolution-matched acquisitions of ten porcine jaws were performed in a PCCT (Naeotom Alpha, Siemens Healthineers) and in a DVT (Orthophos XL, Dentsply Sirona). PCCT images were acquired with 90 kV at a dose of 1 mGy CTDI16 cm. DVT used 85 kV at 4 mGy. Image reconstruction was performed using the standard algorithms of each system to a voxel size of 160 × 160 × 200 µm. The dose-normalized contrast-to-noise ratio (CNRD) was measured between dentine and enamel and dentine and bone. Two readers evaluated overall diagnostic quality of images and quality of relevant structures such as root channels and dentine. RESULTS CNRD is higher in all PCCT acquisitions. CNRD is 37 % higher for the contrast dentine-enamel and 31 % higher for the dentine-bone contrast (p < 0.05). Overall diagnostic image quality was higher for PCCT over DVT (p < 0.02 and p < 0.04 for readers 1 and 2). Quality scores for anatomical structures were higher in PCCT compared to DVT (all p < 0.05). Inter- and intrareader reproducibility were acceptable (all ICC>0.64). CONCLUSIONS PCCT provides an increased image quality over DVT even at a lower dose level and might enable complex dental imaging protocols in the future. CLINICAL SIGNIFICANCE The evolution of photon-counting technology and it's optimization will increasingly move dental imaging towards standardized 3D visualizations providing both minimal radiation exposure and high diagnostic accuracy.
Collapse
Affiliation(s)
- Stefan Sawall
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120, Germany; Medical Faculty, Heidelberg University, Im Neuenheimer Feld 672, Heidelberg 69120, Germany.
| | - Joscha Maier
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120, Germany
| | - Sinan Sen
- Department of Orthodontics, University Hospital of Schleswig-Holstein, Arnold-Heller-Straße 3, Kiel 24105, Germany
| | - Holger Gehrig
- Department of Operative Dentistry, University Hospital Heidelberg, Heidelberg University, Im Neuenheimer Feld 400, Heidelberg 69120, Germany
| | - Ti-Sun Kim
- Department of Operative Dentistry, University Hospital Heidelberg, Heidelberg University, Im Neuenheimer Feld 400, Heidelberg 69120, Germany
| | - Heinz-Peter Schlemmer
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120, Germany
| | - Stefan O Schönberg
- Department of Clinical Radiology and Nuclear Medicine, University Hospital Mannheim, Theodor-Kurz-Ufer 1-3, Mannheim 68167, Germany
| | - Marc Kachelrieß
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120, Germany; Medical Faculty, Heidelberg University, Im Neuenheimer Feld 672, Heidelberg 69120, Germany
| | - Maurice Rütters
- Department of Operative Dentistry, University Hospital Heidelberg, Heidelberg University, Im Neuenheimer Feld 400, Heidelberg 69120, Germany
| |
Collapse
|
3
|
Wei W, Wang SG, Zhang JY, Togn XY, Li BB, Fang X, Pu RW, Zhou YJ, Liu YJ. Implementation of Individualized Low-Dose Computed Tomography-Guided Hook Wire Localization of Pulmonary Nodules: Feasibility and Safety in the Clinical Setting. Diagnostics (Basel) 2023; 13:3235. [PMID: 37892056 PMCID: PMC10606229 DOI: 10.3390/diagnostics13203235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 10/06/2023] [Accepted: 10/13/2023] [Indexed: 10/29/2023] Open
Abstract
Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients' body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student's t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI ≤ 21 kg/m2, 0.56 ± 0.00 mGy and for BMI > 21 kg/m2, 1.48 ± 0.00 mGy) when compared with SDCT (for BMI ≤ 21 kg/m2, 5.24 ± 0.95 mGy and for BMI > 21 kg/m2, 6.69 ± 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI ≤ 21 kg/m2, 56.86 ± 4.73 vs. 533.58 ± 122.06 mGy.cm, and for BMI > 21 kg/m2, 167.02 ± 38.76 vs. 746.01 ± 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI ≤ 21 kg/m2) and 77.68% (for BMI > 21 kg/m2), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Yu-Jing Zhou
- Correspondence: (Y.-J.Z.); (Y.-J.L.); Tel.: +86-180-9887-7000 (Y.J.-L.)
| | - Yi-Jun Liu
- Correspondence: (Y.-J.Z.); (Y.-J.L.); Tel.: +86-180-9887-7000 (Y.J.-L.)
| |
Collapse
|
4
|
Lell M, Kachelrieß M. Computed Tomography 2.0: New Detector Technology, AI, and Other Developments. Invest Radiol 2023; 58:587-601. [PMID: 37378467 PMCID: PMC10332658 DOI: 10.1097/rli.0000000000000995] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/04/2023] [Indexed: 06/29/2023]
Abstract
ABSTRACT Computed tomography (CT) dramatically improved the capabilities of diagnostic and interventional radiology. Starting in the early 1970s, this imaging modality is still evolving, although tremendous improvements in scan speed, volume coverage, spatial and soft tissue resolution, as well as dose reduction have been achieved. Tube current modulation, automated exposure control, anatomy-based tube voltage (kV) selection, advanced x-ray beam filtration, and iterative image reconstruction techniques improved image quality and decreased radiation exposure. Cardiac imaging triggered the demand for high temporal resolution, volume acquisition, and high pitch modes with electrocardiogram synchronization. Plaque imaging in cardiac CT as well as lung and bone imaging demand for high spatial resolution. Today, we see a transition of photon-counting detectors from experimental and research prototype setups into commercially available systems integrated in patient care. Moreover, with respect to CT technology and CT image formation, artificial intelligence is increasingly used in patient positioning, protocol adjustment, and image reconstruction, but also in image preprocessing or postprocessing. The aim of this article is to give an overview of the technical specifications of up-to-date available whole-body and dedicated CT systems, as well as hardware and software innovations for CT systems in the near future.
Collapse
|
5
|
Kachelrieß M. [Risk-minimizing tube current modulation for computed tomography]. RADIOLOGIE (HEIDELBERG, GERMANY) 2023:10.1007/s00117-023-01160-5. [PMID: 37306750 DOI: 10.1007/s00117-023-01160-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Accepted: 04/28/2023] [Indexed: 06/13/2023]
Abstract
AIM/PROBLEM Every computed tomography (CT) examination is accompanied by radiation exposure. The aim is to reduce this as much as possible without compromising image quality by using a tube current modulation technique. STANDARD PROCEDURE CT tube current modulation (TCM), which has been in use for about two decades, adjusts the tube current to the patient's attenuation (in the angular and z‑directions) in a way that minimizes the mAs product (tube current-time product) of the scan without compromising image quality. This mAsTCM, present in all CT devices, is associated with a significant dose reduction in those anatomical areas that have high attenuation differences between anterior-posterior (a.p.) and lateral, particularly the shoulder and pelvis. Radiation risk of individual organs or of the patient is not considered in mAsTCM. METHODOLOGICAL INNOVATION Recently, a TCM method was proposed that directly minimizes the patient's radiation risk by predicting organ dose levels and taking them into account when choosing tube current. It is shown that this so-called riskTCM is significantly superior to mAsTCM in all body regions. To be able to use riskTCM in clinical routine, only a software adaptation of the CT system would be necessary. CONCLUSIONS With riskTCM, significant dose reductions can be achieved compared to the standard procedure, typically around 10%-30%. This is especially true in those body regions where the standard procedure shows only moderate advantages over a scan without any tube current modulation at all. It is now up to the CT vendors to take action and implement riskTCM.
Collapse
Affiliation(s)
- Marc Kachelrieß
- Abteilung Röntgenbildgebung und Computertomographie, Deutsches Krebsforschungszentrum (DFKZ), Heidelberg, Deutschland.
| |
Collapse
|
6
|
Low-Dose CT Imaging of the Pelvis in Follow-up Examinations-Significant Dose Reduction and Impact of Tin Filtration: Evaluation by Phantom Studies and First Systematic Retrospective Patient Analyses. Invest Radiol 2022; 57:789-801. [PMID: 35776429 DOI: 10.1097/rli.0000000000000898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVES Low-dose (LD) computed tomography (CT) is still rarely used in musculoskeletal (MSK) radiology. This study evaluates the potentials of LD CT for follow-up pelvic imaging with special focus on tin filtration (Sn) technology for normal and obese patients with and without metal implants. MATERIALS AND METHODS In a phantom study, 5 different LD and normal-dose (ND) CT protocols with and without tin filtration were tested using a normal and an obese phantom. Iterative reconstruction (IR) and filtered back projection (FBP) were used for CT image reconstruction. In a subsequent retrospective patient study, ND CT images of 45 patients were compared with follow-up tin-filtered LD CT images with a 90% dose reduction. Sixty-four percent of patients contained metal implants at the follow-up examination. Computed tomography images were objectively (image noise, contrast-to-noise ratio [CNR], dose-normalized contrast-to-noise ratio [CNRD]) and subjectively, using a 6-point Likert score, evaluated. In addition, the figure of merit was calculated. For group comparisons, paired t tests, Wilcoxon signed rank test, analysis of variance, or Kruskal-Wallis tests were used, where applicable. RESULTS The LD Sn protocol with 67% dose reduction resulted in equal values in qualitative (Likert score) and quantitative image analysis (image noise) compared with the ND protocol in the phantom study. For follow-up examinations, dose could be reduced up to 90% by using Sn LD CT scans without impairment in the clinical study. However, metal implants resulted in a mild impairment of Sn LD as well as ND CT images. Cancellous bone ( P < 0.001) was assessed worse and cortical bone ( P = 0.063) equally in Sn LD CT images compared with ND CT images. Figure of merit values were significant ( P ≤ 0.02) lower and hence better in Sn LD as in ND protocols. Obese patients benefited in particular from tin filtration in LD MSK imaging in terms of image noise and CNR ( P ≤ 0.05). CONCLUSIONS Low-dose CT scans with tin filtration allow maximum dose reduction while maintaining high image quality for certain clinical purposes, for example, follow-up examinations, especially metal implant position, material loosening, and consolidation controls. Overweight patients benefit particularly from tin filter technology. Although metal implants decrease image quality in ND as well as in Sn LD CT images, this is not a relevant limitation for assessability.
Collapse
|
7
|
Hasegawa A, Ichikawa K, Morioka Y, Kawashima H. A tin filter's dose reduction effect revisited: Using the detectability index in low-dose computed tomography for the chest. Phys Med 2022; 99:61-67. [PMID: 35623206 DOI: 10.1016/j.ejmp.2022.05.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 04/30/2022] [Accepted: 05/15/2022] [Indexed: 10/18/2022] Open
Abstract
PURPOSE To reevaluate a tin filter's (TF) dose reduction effect in computed tomography (CT) using a combination of an anthropomorphic chest phantom and a rod-shaped phantom. METHODS AND MATERIALS A third-generation dual-source CT system equipped with a built-in TF was employed. A chest phantom was scanned under low-dose conditions of 0.2 to 1.0 mGy with the TF at 100 kV (TF100kV) and without it at 100 kV and 120 kV (NF100kV and NF120kV). To eliminate effects other than that of the TF, only filtered back projection (FBP) was used for image reconstruction. On the images of the rod phantom placed inside the lung field, the CT number and the spatial resolution using the modulation transfer function (MTF) were measured. Using these indices plus the noise power spectrum (NPS) that was also measured, the detectability index based on the non-prewhitening model observer (d'NPW) was calculated. RESULTS The CT numbers and MTFs were almost identical across the three conditions. The area under the NPS curve was decreased by 13-17% with the TF compared with non-TF conditions. NPS increases at low frequencies of < 0.06 mm-1 observed in NF120kV and NF100kV were eliminated by TF100kV. The potential dose reduction by the TF, estimated using the d'NPW values, turned out to be 22 to 25%. CONCLUSION Based on the analysis of the FBP images of a chest phantom, the dose reduction attributable only to the TF was estimated at 22-25%, notably lower than those reported in previous studies.
Collapse
Affiliation(s)
- Akira Hasegawa
- Department of Radiological Technology, Faculty of Medical Technology, Niigata University of Health and Welfare, 1398 Shimami-cho, Kita-ku, Niigata-shi, Niigata 950-3198, Japan; Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan.
| | - Katsuhiro Ichikawa
- Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan.
| | - Yusuke Morioka
- Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan; Department of Radiology, Toyama Prefectural Central Hospital, 2-2-78, Nishinagae, Toyama-shi, Toyama 930-8550, Japan.
| | - Hiroki Kawashima
- Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan.
| |
Collapse
|