Zeng Y, Li H, Zhang Q, Wang W, Liu X, Qin B, Pang B, Liu M, Yang K, Quan H, Chang Y, Yang Z. Biological-equivalent-dose-based integrated optimization framework for fast-energy-switching Bragg peak FLASH-RT using single-beam-per-fraction. Med Phys 2024; 51:6292-6304. [PMID: 39031641 DOI: 10.1002/mp.17264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 05/27/2024] [Accepted: 06/09/2024] [Indexed: 07/22/2024] Open
Abstract
BACKGROUNDS When comparing the delivery of all beams per fraction (ABPF) to single beam per fraction (SBPF), it is observed that SBPF not only helps meet the FLASH dose threshold but also mitigates the uncertainty with beam switching in the FLASH effect. However, SBPF might lead to a higher biological equivalent dose in 2 Gy (EQD2) for normal tissues. PURPOSE This study aims to develop an EQD2-based integrated optimization framework (EQD2-IOF), encompassing robust dose, delivery efficiency, and beam orientation optimization (BOO) for Bragg peak FLASH plans using the SBPF treatment schedule. The EQD2-IOF aims to enhance both dose sparing and the FLASH effect. METHODS A superconducting gantry was employed for fast energy switching within 27 ms, while universal range shifters were utilized to improve beam current in the implementation of FLASH plans with five Bragg peak beams. To enhance dose delivery efficiency while maintaining plan quality, a simultaneous dose and spot map optimization (SDSMO) algorithm for single field optimization was incorporated into a Bayesian optimization-based auto-planning algorithm. Subsequently, a BOO algorithm based on Tabu search was developed to select beam angle combinations (BACs) for 10 lung cases. To simultaneously consider dose sparing and FLASH effect, a quantitative model based on dose-dependent dose modification factor (DMF) was used to calculate FLASH-enhanced dose distribution. The EQD2-IOF plan was compared to the plan optimized without SDSMO using BAC selected by a medical physicist (Manual plan) in the SBPF treatment schedule. Meanwhile, the mean EQD2 in the normal tissue was evaluated for the EQD2-IOF plan in both SBPF and ABPF treatment schedules. RESULTS No significant difference was found in D2% and D98% of the target between EQD2-IOF plans and Manual Plans. When using a minimum DMF of 0.67 and a dose threshold of 4 Gy, EQD2-IOF plans showed a significant reduction in FLASH-enhanced EQD2mean of the ipsilateral lung and normal tissue by 10.5% and 11.5%, respectively, compared to Manual plans. For normal tissues that received a dose greater than 70% of the prescription dose, using a minimum DMF of 0.7 for FLASH sparing compensated for the increase in EQD2mean resulting from replacing ABPF with SBPF schedules. CONCLUSIONS The EQD2-IOF can automatically optimize SBPF FLASH-RT plans to achieve optimal sparing of normal tissues. With an energy switching time of 27 ms, the loss of fractionate repairing using SBPF schedules in high-dose regions can be compensated for by the FLASH effect. However, when an energy switching time of 500 ms is utilized, the SBPF schedule needs careful consideration, as the FLASH effect diminishes with longer irradiation time.
Collapse
Affiliation(s)
- Yiling Zeng
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| | - Heng Li
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland, USA
| | - Qi Zhang
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
| | - Wei Wang
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Xu Liu
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Bin Qin
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Bo Pang
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
| | - Muyu Liu
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
| | - Kunyu Yang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| | - Hong Quan
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
| | - Yu Chang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| | - Zhiyong Yang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| |
Collapse
|
2
|
Wang W, Liu X, Liao Y, Zeng Y, Chen Y, Yu B, Yang Z, Gao H, Qin B. Mixed-size spot scanning with a compact large momentum acceptance superconducting (LMA-SC) gantry beamline for proton therapy. Phys Med Biol 2024; 69:10.1088/1361-6560/ad45a6. [PMID: 38688290 PMCID: PMC11265271 DOI: 10.1088/1361-6560/ad45a6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Accepted: 04/30/2024] [Indexed: 05/02/2024]
Abstract
Objective. Lowering treatment costs and improving treatment quality are two primary goals for next-generation proton therapy (PT) facilities. This work will design a compact large momentum acceptance superconducting (LMA-SC) gantry beamline to reduce the footprint and expense of the PT facilities, with a novel mixed-size spot scanning method to improve the sparing of organs at risk (OAR).Approach. For the LMA-SC gantry beamline, the movable energy slit is placed in the middle of the last achromatic bending section, and the beam momentum spread of delivered spots can be easily changed during the treatment. Simultaneously, changing the collimator size can provide spots with various lateral spot sizes. Based on the provided large-size and small-size spot models, the treatment planning with mixed spot scanning is optimized: the interior of the target is irradiated with large-size spots (to cover the uniform-dose interior efficiently), while the peripheral of the target is irradiated with small-size spots (to shape the sharp dose falloff at the peripheral accurately).Main results. The treatment plan with mixed-size spot scanning was evaluated and compared with small and large-size spot scanning for thirteen clinical prostate cases. The mixed-size spot plan had superior target dose homogeneities, better protection of OAR, and better plan robustness than the large-size spot plan. Compared to the small-size spot plan, the mixed-size spot plan had comparable plan quality, better plan robustness, and reduced plan delivery time from 65.9 to 40.0 s.Significance. The compact LMA-SC gantry beamline is proposed with mixed-size spot scanning, with demonstrated footprint reduction and improved plan quality compared to the conventional spot scanning method.
Collapse
Affiliation(s)
- Wei Wang
- State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xu Liu
- State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yicheng Liao
- State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Yiling Zeng
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - Yu Chen
- State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Benzhaoxia Yu
- State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Zhiyong Yang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Hao Gao
- Department of Radiation Oncology, University of Kansas Medical Center, USA
| | - Bin Qin
- State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
3
|
Zeng Y, Li H, Wang W, Liu X, Qin B, Dai S, Pang B, Liu M, Quan H, Yang K, Chang Y, Yang Z. Feasibility study of multiple-energy Bragg peak proton FLASH on a superconducting gantry with large momentum acceptance. Med Phys 2024; 51:2164-2174. [PMID: 38169535 DOI: 10.1002/mp.16932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 11/30/2023] [Accepted: 12/20/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND While the Bragg peak proton beam (BP) is capable of superior target conformity and organs-at-risk sparing than the transmission proton beam (TB), its efficacy in FLASH-RT is hindered by both a slow energy switching process and the beam current. A universal range shifter (URS) can pull back the high-energy proton beam while preserving the beam current. Meanwhile, a superconducting gantry with large momentum acceptance (LMA-SC gantry) enables fast energy switching. PURPOSE This study explores the feasibility of multiple-energy BP FLASH-RT on the LMA-SC gantry. METHOD AND MATERIALS A simultaneous dose and spot map optimization algorithm was developed for BP FLASH-RT treatment planning to improve the dose delivery efficiency. The URS was designed to be 0-27 cm thick, with 1 cm per step. BP plans using the URS were optimized using single-field optimization (SFO) and multiple-field optimization (MFO) for ten prostate cancer patients and ten lung cancer patients. The plan delivery parameters, dose, and dose rate metrics of BP plans were compared to those of TB plans using the parameters of the LMA-SC gantry. RESULTS Compared to TB plans, BP plans significantly reduced MUs by 42.7% (P < 0.001) with SFO and 33.3% (P < 0.001) with MFO for prostate cases. For lung cases, the reduction in MUs was 56.8% (P < 0.001) with SFO and 36.4% (P < 0.001) with MFO. BP plans also outperformed TB plans by reducing mean normal tissue doses. BP-SFO plans achieved a reduction of 56.7% (P < 0.001) for prostate cases and 57.7% (P < 0.001) for lung cases, while BP-MFO plans achieved a reduction of 54.2% (P < 0.001) for the prostate case and 40.0% (P < 0.001) for lung cases. For both TB and BP plans, normal tissues in prostate and lung cases received 100.0% FLASH dose rate coverage (>40 Gy/s). CONCLUSIONS By utilizing the URS and the LMA-SC gantry, it is possible to perform multiple-energy BP FLASH-RT, resulting in better normal tissue sparing, as compared to TB plans.
Collapse
Affiliation(s)
- Yiling Zeng
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| | - Heng Li
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland, USA
| | - Wei Wang
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Xu Liu
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Bin Qin
- State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
| | - Shuyang Dai
- School of Mathematics and Statistics, Wuhan University, Wuhan, P. R. China
| | - Bo Pang
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
| | - Muyu Liu
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
| | - Hong Quan
- Department of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China
| | - Kunyu Yang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| | - Yu Chang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| | - Zhiyong Yang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
- Hubei Key Laboratory of Precision Radiation Oncology, Wuhan, China
| |
Collapse
|
4
|
Knäusl B, Belotti G, Bertholet J, Daartz J, Flampouri S, Hoogeman M, Knopf AC, Lin H, Moerman A, Paganelli C, Rucinski A, Schulte R, Shimizu S, Stützer K, Zhang X, Zhang Y, Czerska K. A review of the clinical introduction of 4D particle therapy research concepts. Phys Imaging Radiat Oncol 2024; 29:100535. [PMID: 38298885 PMCID: PMC10828898 DOI: 10.1016/j.phro.2024.100535] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/12/2023] [Accepted: 01/04/2024] [Indexed: 02/02/2024] Open
Abstract
Background and purpose Many 4D particle therapy research concepts have been recently translated into clinics, however, remaining substantial differences depend on the indication and institute-related aspects. This work aims to summarise current state-of-the-art 4D particle therapy technology and outline a roadmap for future research and developments. Material and methods This review focused on the clinical implementation of 4D approaches for imaging, treatment planning, delivery and evaluation based on the 2021 and 2022 4D Treatment Workshops for Particle Therapy as well as a review of the most recent surveys, guidelines and scientific papers dedicated to this topic. Results Available technological capabilities for motion surveillance and compensation determined the course of each 4D particle treatment. 4D motion management, delivery techniques and strategies including imaging were diverse and depended on many factors. These included aspects of motion amplitude, tumour location, as well as accelerator technology driving the necessity of centre-specific dosimetric validation. Novel methodologies for X-ray based image processing and MRI for real-time tumour tracking and motion management were shown to have a large potential for online and offline adaptation schemes compensating for potential anatomical changes over the treatment course. The latest research developments were dominated by particle imaging, artificial intelligence methods and FLASH adding another level of complexity but also opportunities in the context of 4D treatments. Conclusion This review showed that the rapid technological advances in radiation oncology together with the available intrafractional motion management and adaptive strategies paved the way towards clinical implementation.
Collapse
Affiliation(s)
- Barbara Knäusl
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Gabriele Belotti
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Jenny Bertholet
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Juliane Daartz
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | | | - Mischa Hoogeman
- Department of Medical Physics & Informatics, HollandPTC, Delft, The Netherlands
- Erasmus MC Cancer Institute, University Medical Center Rotterdam, Department of Radiotherapy, Rotterdam, The Netherlands
| | - Antje C Knopf
- Institut für Medizintechnik und Medizininformatik Hochschule für Life Sciences FHNW, Muttenz, Switzerland
| | - Haibo Lin
- New York Proton Center, New York, NY, USA
| | - Astrid Moerman
- Department of Medical Physics & Informatics, HollandPTC, Delft, The Netherlands
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Antoni Rucinski
- Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland
| | - Reinhard Schulte
- Division of Biomedical Engineering Sciences, School of Medicine, Loma Linda University
| | - Shing Shimizu
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Kristin Stützer
- OncoRay – National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
- Helmholtz-Zentrum Dresden – Rossendorf, Institute of Radiooncology – OncoRay, Dresden, Germany
| | - Xiaodong Zhang
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Switzerland
| | - Katarzyna Czerska
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Switzerland
| |
Collapse
|