Peters AA, Wagner B, Spano G, Haupt F, Ebner L, Kunze KP, Schmidt M, Neji R, Botnar R, Prieto C, Jung B, Christe A, Gräni C, Huber AT. Myocardial scar detection in free-breathing Dixon-based fat- and water-separated 3D inversion recovery late-gadolinium enhancement whole heart MRI. Int J Cardiovasc Imaging 2023; 39:135-144. [PMID: 36598693 PMCID: PMC9813059 DOI: 10.1007/s10554-022-02701-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 07/22/2022] [Indexed: 01/09/2023]
Abstract
The aim of this study was to investigate the diagnostic accuracy and reader confidence for late-gadolinium enhancement (LGE) detection of a novel free-breathing, image-based navigated 3D whole-heart LGE sequence with fat-water separation, compared to a free-breathing motion-corrected 2D LGE sequence in patients with ischemic and non-ischemic cardiomyopathy. Cardiac MRI patients including the respective sequences were retrospectively included. Two independent, blinded readers rated image quality, depiction of segmental LGE and documented acquisition time, SNR, CNR and amount of LGE. Results were compared using the Friedman or the Kruskal-Wallis test. For LGE rating, a jackknife free-response receiver operating characteristic analysis was performed with a figure of merit (FOM) calculation. Forty-two patients were included, thirty-two were examined with a 1.5 T-scanner and ten patients with a 3 T-scanner. The mean acquisition time of the 2D sequence was significantly shorter compared to the 3D sequence (07:12 min vs. 09:24 min; p < 0.001). The 3D scan time was significantly shorter when performed at 3 T compared to 1.5 T (07:47 min vs. 09:50 min; p < 0.001). There were no differences regarding SNR, CNR or amount of LGE. 3D imaging had a significantly higher FOM (0.89 vs. 0.78; p < 0.001). Overall image quality ratings were similar, but 3D sequence ratings were higher for fine anatomical structures. Free-breathing motion-corrected 3D LGE with high isotropic resolution results in enhanced LGE-detection with higher confidence and better delineation of fine structures. The acquisition time for 3D imaging was longer, but may be reduced by performing on a 3 T-scanner.
Collapse
Affiliation(s)
- Alan A Peters
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland.
| | - Benedikt Wagner
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Giancarlo Spano
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Fabian Haupt
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Lukas Ebner
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | | | - Michaela Schmidt
- Cardiovascular MR Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Radhouene Neji
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, UK
| | - René Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, UK
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, UK
| | - Bernd Jung
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Andreas Christe
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland
| | - Christoph Gräni
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Adrian T Huber
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, 3010, Bern, Switzerland.
| |
Collapse
|
2
|
Mayer J, Blaszczyk E, Cipriani A, Ferrazzi G, Schulz-Menger J, Schaeffter T, Kolbitsch C. Cardio-respiratory motion-corrected 3D cardiac water-fat MRI using model-based image reconstruction. Magn Reson Med 2022; 88:1561-1574. [PMID: 35775790 DOI: 10.1002/mrm.29284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 03/04/2022] [Accepted: 04/13/2022] [Indexed: 11/07/2022]
Abstract
PURPOSE Myocardial fat infiltrations are associated with a range of cardiomyopathies. The purpose of this study was to perform cardio-respiratory motion-correction for model-based water-fat separation to image fatty infiltrations of the heart in a free-breathing, non-cardiac-triggered high-resolution 3D MRI acquisition. METHODS Data were acquired in nine patients using a free-breathing, non-cardiac-triggered high-resolution 3D Dixon gradient-echo sequence and radial phase encoding trajectory. Motion correction was combined with a model-based water-fat reconstruction approach. Respiratory and cardiac motion models were estimated using a dual-mode registration algorithm incorporating both motion-resolved water and fat information. Qualitative comparisons of fat structures were made between 2D clinical routine reference scans and reformatted 3D motion-corrected images. To evaluate the effect of motion correction the local sharpness of epicardial fat structures was analyzed for motion-averaged and motion-corrected fat images. RESULTS The reformatted 3D motion-corrected reconstructions yielded qualitatively comparable fat structures and fat structure sharpness in the heart as the standard 2D breath-hold. Respiratory motion correction improved the local sharpness on average by 32% ± 24% with maximum improvements of 81% and cardiac motion correction increased the sharpness further by another 15% ± 11% with maximum increases of 31%. One patient showed a fat infiltration in the myocardium and cardio-respiratory motion correction was able to improve its visualization in 3D. CONCLUSION The 3D water-fat separated cardiac images were acquired during free-breathing and in a clinically feasible and predictable scan time. Compared to a motion-averaged reconstruction an increase in sharpness of fat structures by 51% ± 27% using the presented motion correction approach was observed for nine patients.
Collapse
Affiliation(s)
- Johannes Mayer
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
| | - Edyta Blaszczyk
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Experimental and Clinical Research Center, Berlin, Germany. HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Berlin, Germany
- Experimental and Clinical Research Center, a cooperation between the Max Delbrück Center for Molecular Medicine in the Helmholtz Association and Charité Universitätsmedizin Berlin, Berlin, Germany
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
- German Center for Cardiovascular Research (DZHK), partner site Berlin, Berlin, Germany
| | - Alberto Cipriani
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Experimental and Clinical Research Center, Berlin, Germany. HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Berlin, Germany
- Experimental and Clinical Research Center, a cooperation between the Max Delbrück Center for Molecular Medicine in the Helmholtz Association and Charité Universitätsmedizin Berlin, Berlin, Germany
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
- German Center for Cardiovascular Research (DZHK), partner site Berlin, Berlin, Germany
- Department of Cardio-Thoraco-Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | | | - Jeanette Schulz-Menger
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Experimental and Clinical Research Center, Berlin, Germany. HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Berlin, Germany
- Experimental and Clinical Research Center, a cooperation between the Max Delbrück Center for Molecular Medicine in the Helmholtz Association and Charité Universitätsmedizin Berlin, Berlin, Germany
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
- German Center for Cardiovascular Research (DZHK), partner site Berlin, Berlin, Germany
| | - Tobias Schaeffter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
- Department of Medical Engineering, Technical University of Berlin, Berlin, Germany
| | - Christoph Kolbitsch
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Berlin, Germany
| |
Collapse
|
3
|
Milotta G, Munoz C, Kunze KP, Neji R, Figliozzi S, Chiribiri A, Hajhosseiny R, Masci PG, Prieto C, Botnar RM. 3D whole-heart grey-blood late gadolinium enhancement cardiovascular magnetic resonance imaging. J Cardiovasc Magn Reson 2021; 23:62. [PMID: 34024276 PMCID: PMC8142497 DOI: 10.1186/s12968-021-00751-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 03/29/2021] [Indexed: 12/30/2022] Open
Abstract
PURPOSE To develop a free-breathing whole-heart isotropic-resolution 3D late gadolinium enhancement (LGE) sequence with Dixon-encoding, which provides co-registered 3D grey-blood phase-sensitive inversion-recovery (PSIR) and complementary 3D fat volumes in a single scan of < 7 min. METHODS A free-breathing 3D PSIR LGE sequence with dual-echo Dixon readout with a variable density Cartesian trajectory with acceleration factor of 3 is proposed. Image navigators are acquired to correct both inversion recovery (IR)-prepared and reference volumes for 2D translational respiratory motion, enabling motion compensated PSIR reconstruction with 100% respiratory scan efficiency. An intermediate PSIR reconstruction is performed between the in-phase echoes to estimate the signal polarity which is subsequently applied to the IR-prepared water volume to generate a water grey-blood PSIR image. The IR-prepared water volume is obtained using a water/fat separation algorithm from the corresponding dual-echo readout. The complementary fat-volume is obtained after water/fat separation of the reference volume. Ten patients (6 with myocardial scar) were scanned with the proposed water/fat grey-blood 3D PSIR LGE sequence at 1.5 T and compared to breath-held grey-blood 2D LGE sequence in terms of contrast ratio (CR), contrast-to-noise ratio (CNR), scar depiction, scar transmurality, scar mass and image quality. RESULTS Comparable CRs (p = 0.98, 0.40 and 0.83) and CNRs (p = 0.29, 0.40 and 0.26) for blood-myocardium, scar-myocardium and scar-blood respectively were obtained with the proposed free-breathing 3D water/fat LGE and 2D clinical LGE scan. Excellent agreement for scar detection, scar transmurality, scar mass (bias = 0.29%) and image quality scores (from 1: non-diagnostic to 4: excellent) of 3.8 ± 0.42 and 3.6 ± 0.69 (p > 0.99) were obtained with the 2D and 3D PSIR LGE approaches with comparable total acquisition time (p = 0.29). Similar agreement in intra and inter-observer variability were obtained for the 2D and 3D acquisition respectively. CONCLUSION The proposed approach enabled the acquisition of free-breathing motion-compensated isotropic-resolution 3D grey-blood PSIR LGE and fat volumes. The proposed approach showed good agreement with conventional 2D LGE in terms of CR, scar depiction and scan time, while enabling free-breathing acquisition, whole-heart coverage, reformatting in arbitrary views and visualization of both water and fat information.
Collapse
Affiliation(s)
- Giorgia Milotta
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK.
| | - Camila Munoz
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
| | - Karl P Kunze
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Stefano Figliozzi
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
| | - Amedeo Chiribiri
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
| | - Reza Hajhosseiny
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
| | - Pier Giorgio Masci
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - René M Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital (3rd Floor - Lambeth Wing), Westminster Bridge Road, London, SE1 7EH, UK
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
4
|
Zeilinger MG, Wiesmüller M, Forman C, Schmidt M, Munoz C, Piccini D, Kunze KP, Neji R, Botnar RM, Prieto C, Uder M, May M, Wuest W. 3D Dixon water-fat LGE imaging with image navigator and compressed sensing in cardiac MRI. Eur Radiol 2020; 31:3951-3961. [PMID: 33263160 PMCID: PMC8128857 DOI: 10.1007/s00330-020-07517-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 10/11/2020] [Accepted: 11/13/2020] [Indexed: 12/25/2022]
Abstract
Objectives To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. Material and methods Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and examined with 1.5 T MRI. Overall subjective image quality, LGE pattern and extent, diagnostic confidence for detection of LGE, and scan time were evaluated and compared to standard 2D LGE imaging. Robustness of Dixon fat suppression was evaluated for 3D Dixon LGE imaging. For statistical analysis, the non-parametric Wilcoxon rank sum test was performed. Results LGE was rated as ischemic in 9 patients and non-ischemic in 11 patients while it was absent in 20 patients. Image quality and diagnostic confidence were comparable between both techniques (p = 0.67 and p = 0.66, respectively). LGE extent with respect to segmental or transmural myocardial enhancement was identical between 2D and 3D (water-only and in-phase). LGE size was comparable (3D 8.4 ± 7.2 g, 2D 8.7 ± 7.3 g, p = 0.19). Good or excellent fat suppression was achieved in 93% of the 3D LGE datasets. In 6 patients with pericarditis, the 3D sequence with Dixon fat suppression allowed for a better detection of pericardial LGE. Scan duration was significantly longer for 3D imaging (2D median 9:32 min vs. 3D median 10:46 min, p = 0.001). Conclusion The 3D LGE sequence provides comparable LGE detection compared to 2D imaging and seems to be superior in evaluating the extent of pericardial involvement in patients suspected with pericarditis due to the robust Dixon fat suppression. Key Points • Three-dimensional LGE imaging provides high-resolution detection of myocardial scarring. • Robust Dixon water-fat separation aids in the assessment of pericardial disease. • The 2D image navigator technique enables 100% respiratory scan efficacy and permits predictable scan times.
Collapse
Affiliation(s)
| | - Marco Wiesmüller
- Institute of Diagnostic Radiology, University Hospital of Erlangen, Erlangen, Germany
| | - Christoph Forman
- Cardiovascular MR Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Michaela Schmidt
- Cardiovascular MR Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Camila Munoz
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Davide Piccini
- Advanced Clinical Imaging Technology, Siemens Healthcare IM BM PI, Lausanne, Switzerland
| | - Karl-Philipp Kunze
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,MR Research Collaborations, Siemens Healthcare GmbH, Frimley, UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.,MR Research Collaborations, Siemens Healthcare GmbH, Frimley, UK
| | - René Michael Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Michael Uder
- Institute of Diagnostic Radiology, University Hospital of Erlangen, Erlangen, Germany
| | - Matthias May
- Institute of Diagnostic Radiology, University Hospital of Erlangen, Erlangen, Germany
| | - Wolfgang Wuest
- Institute of Diagnostic Radiology, University Hospital of Erlangen, Erlangen, Germany
| |
Collapse
|
5
|
Abstract
Cardiac magnetic resonance (CMR) imaging is an effective method for noninvasively imaging the heart which in the last two decades impressively enhanced spatial and temporal resolution and imaging speed, broadening its spectrum of applications in cardiovascular disease. CMR imaging techniques are designed to noninvasively assess cardiovascular morphology, ventricular function, myocardial perfusion, tissue characterization, flow quantification and coronary artery disease. These intrinsic features yield CMR suitable for diagnosis, follow-up and longitudinal monitoring after treatment of cardiovascular diseases. The aim of this paper is to review the technical basis of CMR, from cardiac imaging planes to cardiac imaging sequences.
Collapse
|
6
|
Munoz C, Bustin A, Neji R, Kunze KP, Forman C, Schmidt M, Hajhosseiny R, Masci PG, Zeilinger M, Wuest W, Botnar RM, Prieto C. Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging. J Cardiovasc Magn Reson 2020; 22:53. [PMID: 32684167 PMCID: PMC7370486 DOI: 10.1186/s12968-020-00649-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 06/17/2020] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Conventional 2D inversion recovery (IR) and phase sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) have been widely incorporated into routine CMR for the assessment of myocardial viability. However, reliable suppression of fat signal, and increased isotropic spatial resolution and volumetric coverage within a clinically feasible scan time remain a challenge. In order to address these challenges, this work proposes a highly efficient respiratory motion-corrected 3D whole-heart water/fat LGE imaging framework. METHODS An accelerated IR-prepared 3D dual-echo acquisition and motion-corrected reconstruction framework for whole-heart water/fat LGE imaging was developed. The acquisition sequence includes 2D image navigators (iNAV), which are used to track the respiratory motion of the heart and enable 100% scan efficiency. Non-rigid motion information estimated from the 2D iNAVs and from the data itself is integrated into a high-dimensional patch-based undersampled reconstruction technique (HD-PROST), to produce high-resolution water/fat 3D LGE images. A cohort of 20 patients with known or suspected cardiovascular disease was scanned with the proposed 3D water/fat LGE approach. 3D water LGE images were compared to conventional breath-held 2D LGE images (2-chamber, 4-chamber and stack of short-axis views) in terms of image quality (1: full diagnostic to 4: non-diagnostic) and presence of LGE findings. RESULTS Image quality was considered diagnostic in 18/20 datasets for both 2D and 3D LGE magnitude images, with comparable image quality scores (2D: 2.05 ± 0.72, 3D: 1.88 ± 0.90, p-value = 0.62) and overall agreement in LGE findings. Acquisition time for isotropic high-resolution (1.3mm3) water/fat LGE images was 8.0 ± 1.4 min (3-fold acceleration, 60-88 slices covering the whole heart), while 2D LGE images were acquired in 5.6 ± 2.2 min (12-18 slices, including pauses between breath-holds) albeit with a lower spatial resolution (1.40-1.75 mm in-plane × 8 mm slice thickness). CONCLUSION A novel framework for motion-corrected whole-heart 3D water/fat LGE imaging has been introduced. The method was validated in patients with known or suspected cardiovascular disease, showing good agreement with conventional breath-held 2D LGE imaging, but offering higher spatial resolution, improved volumetric coverage and good image quality from a free-breathing acquisition with 100% scan efficiency and predictable scan time.
Collapse
Affiliation(s)
- Camila Munoz
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
| | - Aurelien Bustin
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK
- MR Research Collaborations, Siemens Healthcare, Frimley, UK
| | - Karl P Kunze
- MR Research Collaborations, Siemens Healthcare, Frimley, UK
| | - Christoph Forman
- Cardiovascular MR Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Michaela Schmidt
- Cardiovascular MR Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Reza Hajhosseiny
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK
| | - Pier-Giorgio Masci
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK
| | - Martin Zeilinger
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| | - Wolfgang Wuest
- Institute of Radiology, University Hospital Erlangen, Erlangen, Germany
| | - René M Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK
| |
Collapse
|
7
|
Lapinskas T, Schnackenburg B, Kouwenhoven M, Gebker R, Berger A, Zaliunas R, Pieske B, Kelle S. Fatty metaplasia quantification and impact on regional myocardial function as assessed by advanced cardiac MR imaging. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017. [PMID: 28620752 PMCID: PMC5813049 DOI: 10.1007/s10334-017-0639-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Objective This study aimed to investigate the advantages of recently developed cardiac imaging techniques of fat–water separation and feature tracking to characterize better individuals with chronic myocardial infarction (MI). Materials and methods Twenty patients who had a previous MI underwent CMR imaging. The study protocol included routine cine and late gadolinium enhancement (LGE) technique. In addition, mDixon LGE imaging was performed in every patient. Left ventricular (LV) circumferential (EccLV) and radial (ErrLV) strain were calculated using dedicated software (CMR42, Circle, Calgary, Canada). The extent of global scar was measured in LGE and fat–water separated images to compare conventional and recent CMR imaging techniques. Results The infarct size derived from conventional LGE and fat–water separated images was similar. However, detection of lipomatous metaplasia was only possible with mDixon imaging. Subjects with fat deposition demonstrated a significantly smaller percentage of fibrosis than those without fat (10.68 ± 5.07% vs. 13.83 ± 6.30%; p = 0.005). There was no significant difference in EccLV or ErrLV between myocardial segments containing fibrosis only and fibrosis with fat. However, EccLV and ErrLV values were significantly higher in myocardial segments adjacent to fibrosis with fat deposition than in those adjacent to LGE only. Conclusions Advanced CMR imaging ensures more detailed tissue characterization in patients with chronic MI without a relevant increase in imaging and post-processing time. Fatty metaplasia may influence regional myocardial deformation especially in the myocardial segments adjacent to scar tissue. A simplified and shortened myocardial viability CMR protocol might be useful to better characterize and stratify patients with chronic MI.
Collapse
Affiliation(s)
- Tomas Lapinskas
- Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Eiveniu Street 2, 50161, Kaunas, Lithuania. .,Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany. .,DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany.
| | | | - Marc Kouwenhoven
- Philips Healthcare, Veenpluis 4-6, 5684 PC, Best, The Netherlands
| | - Rolf Gebker
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany
| | - Alexander Berger
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Remigijus Zaliunas
- Department of Cardiology, Medical Academy, Lithuanian University of Health Sciences, Eiveniu Street 2, 50161, Kaunas, Lithuania
| | - Burkert Pieske
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany
| | - Sebastian Kelle
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany
| |
Collapse
|
8
|
van Ewijk PA, Schrauwen-Hinderling VB, Bekkers SCAM, Glatz JFC, Wildberger JE, Kooi ME. MRS: a noninvasive window into cardiac metabolism. NMR IN BIOMEDICINE 2015; 28:747-66. [PMID: 26010681 DOI: 10.1002/nbm.3320] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Revised: 04/02/2015] [Accepted: 04/07/2015] [Indexed: 05/21/2023]
Abstract
A well-functioning heart requires a constant supply of a balanced mixture of nutrients to be used for the production of adequate amounts of adenosine triphosphate, which is the main energy source for most cellular functions. Defects in cardiac energy metabolism are linked to several myocardial disorders. MRS can be used to study in vivo changes in cardiac metabolism noninvasively. MR techniques allow repeated measurements, so that disease progression and the response to treatment or to a lifestyle intervention can be monitored. It has also been shown that MRS can predict clinical heart failure and death. This article focuses on in vivo MRS to assess cardiac metabolism in humans and experimental animals, as experimental animals are often used to investigate the mechanisms underlying the development of metabolic diseases. Various MR techniques, such as cardiac (31) P-MRS, (1) H-MRS, hyperpolarized (13) C-MRS and Dixon MRI, are described. A short overview of current and emerging applications is given. Cardiac MRS is a promising technique for the investigation of the relationship between cardiac metabolism and cardiac disease. However, further optimization of scan time and signal-to-noise ratio is required before broad clinical application. In this respect, the ongoing development of advanced shimming algorithms, radiofrequency pulses, pulse sequences, (multichannel) detection coils, the use of hyperpolarized nuclei and scanning at higher magnetic field strengths offer future perspective for clinical applications of MRS.
Collapse
Affiliation(s)
- Petronella A van Ewijk
- Maastricht University Medical Center, Human Biology, Maastricht, the Netherlands
- Maastricht University Medical Center, Radiology, Maastricht, the Netherlands
- Maastricht University Medical Center, NUTRIM - School for Nutrition, Toxicology and Metabolism, Maastricht, the Netherlands
| | - Vera B Schrauwen-Hinderling
- Maastricht University Medical Center, Human Biology, Maastricht, the Netherlands
- Maastricht University Medical Center, Radiology, Maastricht, the Netherlands
- Maastricht University Medical Center, NUTRIM - School for Nutrition, Toxicology and Metabolism, Maastricht, the Netherlands
| | | | - Jan F C Glatz
- Maastricht University Medical Center, Molecular Genetics, Maastricht, the Netherlands
- Maastricht University Medical Center, CARIM - Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
| | | | - M Eline Kooi
- Maastricht University Medical Center, Radiology, Maastricht, the Netherlands
- Maastricht University Medical Center, NUTRIM - School for Nutrition, Toxicology and Metabolism, Maastricht, the Netherlands
- Maastricht University Medical Center, CARIM - Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
| |
Collapse
|
9
|
Kellman P, Bandettini WP, Mancini C, Hammer-Hansen S, Hansen MS, Arai AE. Characterization of myocardial T1-mapping bias caused by intramyocardial fat in inversion recovery and saturation recovery techniques. J Cardiovasc Magn Reson 2015; 17:33. [PMID: 25958014 PMCID: PMC4425910 DOI: 10.1186/s12968-015-0136-y] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2015] [Accepted: 04/24/2015] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Quantitative measurement of T1 in the myocardium may be used to detect both focal and diffuse disease processes such as interstitial fibrosis or edema. A partial volume problem exists when a voxel in the myocardium also contains fat. Partial volume with fat occurs at tissue boundaries or within the myocardium in the case of lipomatous metaplasia of replacement fibrosis, which is commonly seen in chronic myocardial infarction. The presence of fat leads to a bias in T1 measurement. The mechanism for this artifact for widely used T1 mapping protocols using balanced steady state free precession readout and the dependence on off-resonance frequency are described in this paper. METHODS Simulations were performed to illustrate the behavior of mono-exponential fitting to bi-exponential mixtures of myocardium and fat with varying fat fractions. Both inversion recovery and saturation recovery imaging protocols using balanced steady state free precession are considered. In-vivo imaging with T1-mapping, water/fat separated imaging, and late enhancement imaging was performed on subjects with chronic myocardial infarction. RESULTS In n = 17 subjects with chronic myocardial infarction, lipomatous metaplasia is evident in 8 patients (47%). Fat fractions as low as 5% caused approximately 6% T1 elevation for the out-of-phase condition, and approximately 5% reduction of T1 for the in-phase condition. T1 bias in excess of 1000 ms was observed in lipomatous metaplasia with fat fraction of 38% in close agreement with simulation of the specific imaging protocols. CONCLUSIONS Measurement of the myocardial T1 by widely used balanced steady state free precession mapping methods is subject to bias when there is a mixture of water and fat in the myocardium. Intramyocardial fat is frequently present in myocardial scar tissue due lipomatous metaplasia, a process affecting myocardial infarction and some non-ischemic cardiomyopathies. In cases of lipomatous metaplasia, the T1 biases will be additive or subtractive depending on whether the center frequency corresponds to the myocardium and fat being in-phase or out-of-phase, respectively. It is important to understand this mechanism, which may otherwise lead to erroneous interpretation.
Collapse
Affiliation(s)
- Peter Kellman
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, 10 Center Drive MSC-1061, Bethesda, MD, 20892, USA.
| | - W Patricia Bandettini
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, 10 Center Drive MSC-1061, Bethesda, MD, 20892, USA.
| | - Christine Mancini
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, 10 Center Drive MSC-1061, Bethesda, MD, 20892, USA.
| | - Sophia Hammer-Hansen
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, 10 Center Drive MSC-1061, Bethesda, MD, 20892, USA.
| | - Michael S Hansen
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, 10 Center Drive MSC-1061, Bethesda, MD, 20892, USA.
| | - Andrew E Arai
- National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, 10 Center Drive MSC-1061, Bethesda, MD, 20892, USA.
| |
Collapse
|
10
|
Petibon Y, El Fakhri G, Nezafat R, Johnson N, Brady T, Ouyang J. Towards coronary plaque imaging using simultaneous PET-MR: a simulation study. Phys Med Biol 2014; 59:1203-22. [PMID: 24556608 DOI: 10.1088/0031-9155/59/5/1203] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Coronary atherosclerotic plaque rupture is the main cause of myocardial infarction and the leading killer in the US. Inflammation is a known bio-marker of plaque vulnerability and can be assessed non-invasively using fluorodeoxyglucose-positron emission tomography imaging (FDG-PET). However, cardiac and respiratory motion of the heart makes PET detection of coronary plaque very challenging. Fat surrounding coronary arteries allows the use of MRI to track plaque motion during simultaneous PET-MR examination. In this study, we proposed and assessed the performance of a fat-MR based coronary motion correction technique for improved FDG-PET coronary plaque imaging in simultaneous PET-MR. The proposed methods were evaluated in a realistic four-dimensional PET-MR simulation study obtained by combining patient water-fat separated MRI and XCAT anthropomorphic phantom. Five small lesions were digitally inserted inside the patients coronary vessels to mimic coronary atherosclerotic plaques. The heart of the XCAT phantom was digitally replaced with the patient's heart. Motion-dependent activity distributions, attenuation maps, and fat-MR volumes of the heart, were generated using the XCAT cardiac and respiratory motion fields. A full Monte Carlo simulation using Siemens mMR's geometry was performed for each motion phase. Cardiac/respiratory motion fields were estimated using non-rigid registration of the transformed fat-MR volumes and incorporated directly into the system matrix of PET reconstruction along with motion-dependent attenuation maps. The proposed motion correction method was compared to conventional PET reconstruction techniques such as no motion correction, cardiac gating, and dual cardiac-respiratory gating. Compared to uncorrected reconstructions, fat-MR based motion compensation yielded an average improvement of plaque-to-background contrast of 29.6%, 43.7%, 57.2%, and 70.6% for true plaque-to-blood ratios of 10, 15, 20 and 25:1, respectively. Channelized Hotelling observer (CHO) signal-to-noise ratio (SNR) was used to quantify plaque detectability. CHO-SNR improvement ranged from 105% to 128% for fat-MR-based motion correction as compared to no motion correction. Likewise, CHO-SNR improvement ranged from 348% to 396% as compared to both cardiac and dual cardiac-respiratory gating approaches. Based on this study, our approach, a fat-MR based motion correction for coronary plaque PET imaging using simultaneous PET-MR, offers great potential for clinical practice. The ultimate performance and limitation of our approach, however, must be fully evaluated in patient studies.
Collapse
Affiliation(s)
- Y Petibon
- Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, MA 02114, USA. Sorbonne Universités, UPMC Université Paris 06, Inserm UMR_S 1146 CNRS UMR 7371, Laboratoire d'Imagerie Biomédicale, F-75013, Paris, France
| | | | | | | | | | | |
Collapse
|
11
|
Eggers H, Börnert P. Chemical shift encoding-based water-fat separation methods. J Magn Reson Imaging 2014; 40:251-68. [PMID: 24446249 DOI: 10.1002/jmri.24568] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 12/12/2013] [Indexed: 12/13/2022] Open
Abstract
The suppression of signal from fat constitutes a basic requirement in many applications of magnetic resonance imaging. To date, this is predominantly achieved during data acquisition, using fat saturation, inversion recovery, or water excitation methods. Postponing the separation of signal from water and fat until image reconstruction holds the promise of resolving some of the problems associated with these methods, such as failure in the presence of field inhomogeneities or contrast agents. In this article, methods are reviewed that rely on the difference in chemical shift between the hydrogen atoms in water and fat to perform such a retrospective separation. The basic principle underlying these so-called Dixon methods is introduced, and some fundamental implementations of the required chemical shift encoding in the acquisition and the subsequent water-fat separation in the reconstruction are described. Practical issues, such as the selection of key parameters and the appearance of typical artifacts, are illustrated, and a broad range of applications is demonstrated, including abdominal, cardiovascular, and musculoskeletal imaging. Finally, advantages and disadvantages of these Dixon methods are summarized, and emerging opportunities arising from the availability of information on the amount and distribution of fat are discussed.
Collapse
|
12
|
Taviani V, Hernando D, Francois CJ, Shimakawa A, Vigen KK, Nagle SK, Schiebler ML, Grist TM, Reeder SB. Whole-heart chemical shift encoded water-fat MRI. Magn Reson Med 2013; 72:718-25. [PMID: 24186810 DOI: 10.1002/mrm.24982] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2013] [Revised: 09/12/2013] [Accepted: 09/12/2013] [Indexed: 12/21/2022]
Abstract
PURPOSE To develop and evaluate a free-breathing chemical-shift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). METHODS We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluated its performance at 3T in healthy volunteers (N = 6) and patients (N = 20). CSE-SPGR, 3D SPGR, and 3D balanced-SSFP with chemical fat saturation were compared in six healthy subjects with images evaluated for overall image quality, level of residual artifacts, and quality of fat suppression. A similar scoring system was used for the patient datasets. RESULTS Images of diagnostic quality were acquired in all but one subject. CSE-SPGR performed similarly to SPGR with fat saturation, although it provided a more uniform fat suppression over the whole field of view. Balanced-SSFP performed worse than SPGR-based methods. In patients, CSE-SPGR produced excellent fat suppression near metal. Overall image quality was either good (7/20) or excellent (12/20) in all but one patient. There were significant artifacts in 5/20 clinical cases. CONCLUSION CSE-SPGR is a promising technique for whole-heart water-fat imaging during free-breathing. The robust fat suppression in the water-only image could improve assessment of complex morphology at 3T and in the presence of off-resonance, with additional information contained in the fat-only image.
Collapse
Affiliation(s)
- Valentina Taviani
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Shaw JL, Knowles BR, Goldfarb JW, Manning WJ, Peters DC. Left atrial late gadolinium enhancement with water-fat separation: the importance of phase-encoding order. J Magn Reson Imaging 2013; 40:119-25. [PMID: 24105717 DOI: 10.1002/jmri.24340] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Accepted: 07/10/2013] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To compare two late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) methods: a Dixon LGE sequence with sequential phase-encoding order, reconstructed using water-fat separation, and standard fat-saturated LGE. MATERIALS AND METHODS We implemented a dual-echo Dixon LGE method for reconstructing water-only images and compared it to fat-saturated LGE in 12 patients prior to their first pulmonary vein isolation (PVI) procedure. Images were analyzed for quality and fat-suppression. Regions of the left atrium were evaluated by a blinded observer (1 = prominent enhancement, 0 = mild or absent enhancement) on two sets of images (fat-saturated and water-only LGE) and agreement was assessed. RESULTS Water-only LGE showed a trend toward better fat-suppression (P = 0.06), with a significantly more homogeneous blood pool signal and reduced inflow artifacts (both P < 0.01). Agreement between fat-saturated LGE and water-only methods was found in 84% of regions, significantly correlated by chi-squared test (P < 0.001). The kappa value was 0.52 (moderate). The average number of enhancing segments was higher for fat-saturated LGE than water-only LGE (4.2 ± 2.7 vs. 3.2 ± 2.9, P = 0.03). CONCLUSION The two-point Dixon LGE technique reduces artifacts due to a centric k-space order. A similar enhancement pattern was observed irrespective of the LGE technique, with more enhancement detected by fat-saturated LGE.
Collapse
Affiliation(s)
- Jaime L Shaw
- Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA; Department of Biomedical Sciences, Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | | | | | | | | |
Collapse
|
14
|
Goldfarb JW, Arnold-Anteraper S. Water-fat separation imaging of the heart with standard magnetic resonance bSSFP CINE imaging. Magn Reson Med 2013; 71:2096-104. [PMID: 23904254 DOI: 10.1002/mrm.24879] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2013] [Revised: 06/18/2013] [Accepted: 06/18/2013] [Indexed: 12/19/2022]
Abstract
PURPOSE To study balanced steady-state free precession CINE phase-sensitive water-fat separation imaging in four cardiac imaging planes to determine the necessary phase correction and image artifacts particular to this technique. METHODS Ten healthy volunteers and two subjects with known heart pathologies were studied with standard balanced steady-state free precession CINE imaging. Water-only and fat-only images were calculated using sign detection of the real part of the complex image after phase correction with constant and linear terms. Phase correction values were determined using both manual and automated methods. Differences in phase correction values between imaging planes, cardiac phases, coil elements, automated image reconstruction parameters as well as artifact scores between the automated and manual methods were studied with statistical tests. RESULTS Water-fat separation performed well in the heart after constant and linear phase correction. Both constant (p = 0.8) and linear x (p = 1) and y (p = 1) phase correction values did not vary significantly across cardiac phases, but varied significantly among the coils (p < 0.001) and imaging planes (p < 0.001). False water-fat separation artifacts were most frequent in the chest/back and also were present at the mitral and aortic valves. CONCLUSION Constant and linear phase correction is necessary to provide consistent results in standard imaging planes using a balanced steady-state free precession water-fat separation postprocessing algorithm applied to standard cardiac CINE imaging.
Collapse
Affiliation(s)
- James W Goldfarb
- Department of Research and Education, Saint Francis Hospital, Roslyn, New York, USA; Program in Biomedical Engineering, SUNY Stony Brook, Stony Brook, New York, USA
| | | |
Collapse
|
15
|
Saranathan M, Glockner J. Three-dimensional dixon fat-water separated rapid breathheld imaging of myocardial infarction. J Magn Reson Imaging 2013; 38:1362-8. [PMID: 23559381 DOI: 10.1002/jmri.24113] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Accepted: 02/12/2013] [Indexed: 01/23/2023] Open
Abstract
PURPOSE To develop a breathhold three-dimensional (3D) Dixon technique for fat suppressed imaging of myocardial infarction. MATERIALS AND METHODS A pulse sequence was developed that uses a radial fan-beam k-space segmentation scheme for efficient coverage of k-space, enabling 3D scans in a single breathhold. The sequence uses a dual-echo bipolar readout to enable Dixon fat-water separation for improved visualization of epicardial and pericardial delayed enhancement. The 3D Dixon method was compared with a conventional 2D fast gradient recalled echo (FGRE) -based technique in 25 patients. RESULTS Pericardial visualization scores and confidence were higher while overall image quality and artifacts were slightly worse for 3D Dixon compared with 2D FGRE. Robust fat suppression was achieved in 21 of 25 cases using the 3D Dixon method. CONCLUSION A 3D breathhold method for fat-water separated imaging of myocardial delayed enhancement was developed and validated.
Collapse
|
16
|
Börnert P, Koken P, Nehrke K, Eggers H, Ostendorf P. Water/fat-resolved whole-heart Dixon coronary MRA: An initial comparison. Magn Reson Med 2013; 71:156-63. [DOI: 10.1002/mrm.24648] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2012] [Revised: 12/10/2012] [Accepted: 12/25/2012] [Indexed: 11/10/2022]
Affiliation(s)
- Peter Börnert
- Philips Research Europe; Hamburg Germany
- Department of Radiology; Leiden University Medical Center; Leiden The Netherlands
| | | | - Kay Nehrke
- Philips Research Europe; Hamburg Germany
| | | | - Peter Ostendorf
- Centre of Preventive Medicine; Marienkrankenhaus Hamburg Germany
| |
Collapse
|
17
|
Kellman P, Arai AE. Cardiac imaging techniques for physicians: late enhancement. J Magn Reson Imaging 2013; 36:529-42. [PMID: 22903654 DOI: 10.1002/jmri.23605] [Citation(s) in RCA: 118] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Late enhancement imaging is used to diagnose and characterize a wide range of ischemic and nonischemic cardiomyopathies, and its use has become ubiquitous in the cardiac MR exam. As the use of late enhancement imaging has matured and the span of applications has widened, the demands on image quality have grown. The characterization of subendocardial MI now includes the accurate quantification of scar size, shape, and characterization of borders which have been shown to have prognostic significance. More diverse patterns of late enhancement including patchy, mid-wall, subepicardial, or diffuse enhancement are of interest in diagnosing nonischemic cardiomyopathies. As clinicians are examining late enhancement images for more subtle indication of fibrosis, the demand for lower artifacts has increased. A range of new techniques have emerged to improve the speed and quality of late enhancement imaging including: methods for acquisition during free breathing, and fat water separated imaging for characterizing fibrofatty infiltration and reduction of artifacts related to the presence of fat. Methods for quantification of T1 and extracellular volume fraction are emerging to tackle the issue of discriminating globally diffuse fibrosis from normal healthy tissue which is challenging using conventional late enhancement methods. The aim of this review will be to describe the current state of the art and to provide a guide to various clinical protocols that are commonly used.
Collapse
Affiliation(s)
- Peter Kellman
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA.
| | | |
Collapse
|
18
|
Havla L, Basha T, Rayatzadeh H, Shaw JL, Manning WJ, Reeder SB, Kozerke S, Nezafat R. Improved fat water separation with water selective inversion pulse for inversion recovery imaging in cardiac MRI. J Magn Reson Imaging 2012; 37:484-90. [PMID: 22927327 DOI: 10.1002/jmri.23779] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2012] [Accepted: 07/20/2012] [Indexed: 12/22/2022] Open
Abstract
PURPOSE To develop an improved chemical shift-based water-fat separation sequence using a water-selective inversion pulse for inversion recovery 3D contrast-enhanced cardiac magnetic resonance imaging (MRI). MATERIALS AND METHODS In inversion recovery sequences the fat signal is substantially reduced due to the application of a nonselective inversion pulse. Therefore, for simultaneous visualization of water, fat, and myocardial enhancement in inversion recovery-based sequences such as late gadolinium enhancement imaging, two separate scans are used. To overcome this, the nonselective inversion pulse is replaced with a water-selective inversion pulse. Imaging was performed in phantoms, nine healthy subjects, and nine patients with suspected arrhythmogenic right ventricular cardiomyopathy plus one patient for tumor/mass imaging. In patients, images with conventional turbo-spin echo (TSE) with and without fat saturation were acquired prior to contrast injection for fat assessment. Subjective image scores (1 = poor, 4 = excellent) were used for image assessment. RESULTS Phantom experiments showed a fat signal-to-noise ratio (SNR) increase between 1.7 to 5.9 times for inversion times of 150 and 300 msec, respectively. The water-selective inversion pulse retains the fat signal in contrast-enhanced cardiac MR, allowing improved visualization of fat in the water-fat separated images of healthy subjects with a score of 3.7 ± 0.6. Patient images acquired with the proposed sequence were scored higher when compared with a TSE sequence (3.5 ± 0.7 vs. 2.2 ± 0.5, P < 0.05). CONCLUSION The water-selective inversion pulse retains the fat signal in inversion recovery-based contrast-enhanced cardiac MR, allowing simultaneous visualization of water and fat.
Collapse
Affiliation(s)
- Lukas Havla
- Department of Medicine, Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, Massachusetts 02215, USA
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Okayama S, Ayako S, Somekawa S, Uemura S, Kubota Y, Saito Y. Feasibility of dual gradient-echo in-phase and opposed-phase magnetic resonance imaging for the evaluation of epicardial fat. Acta Radiol 2011; 52:723-9. [PMID: 21586607 DOI: 10.1258/ar.2011.100454] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND Dual gradient-echo in-phase (IP) and opposed-phase (OP) magnetic resonance imaging (MRI) can evaluate small amounts of fat, and is widely used for imaging abdominal organs. Epicardial fat has recently been revealed as having an important role in the development of heart disease, but IPOP-MRI has not been widely applied in this field, probably because of cardiac motion artifacts. PURPOSE To demonstrate the feasibility of IPOP-MRI with electrocardiography (ECG)-gating for evaluation of epicardial fat in the normal human heart, compared to black-blood T1-weighted imaging (T1WI). MATERIAL AND METHODS Ten healthy volunteers were studied. Epicardial fat volume was quantitatively evaluated on OP-from-IP subtraction images and T1-weighted images. RESULTS Epicardial fat was clearly visualized on the subtraction images as hyperintense areas that corresponded to regions identified as epicardial fat on the T1-weighted images. Epicardial fat volume correlated well between the two methods (r = 0.93, P <0.0001), and tended to be larger on the subtraction images than on the T1-weighted images (91.4 ± 30.1 vs. 84.1 ± 30.5 mL, P = 0.07). CONCLUSION IPOP-MRI with ECG-gating may be a useful alternative method to black-blood T1WI for evaluation of epicardial fat.
Collapse
Affiliation(s)
- Satoshi Okayama
- First Department of Internal Medicine, Nara Medical University, Nara
| | - Seno Ayako
- First Department of Internal Medicine, Nara Medical University, Nara
| | - Satoshi Somekawa
- First Department of Internal Medicine, Nara Medical University, Nara
| | - Shiro Uemura
- First Department of Internal Medicine, Nara Medical University, Nara
| | | | - Yoshihiko Saito
- First Department of Internal Medicine, Nara Medical University, Nara
| |
Collapse
|
20
|
Goldfarb JW. Magnetic resonance separation imaging using a divided inversion recovery technique (DIRT). Magn Reson Med 2010; 63:1007-14. [PMID: 20373401 DOI: 10.1002/mrm.22281] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The divided inversion recovery technique is an MRI separation method based on tissue T(1) relaxation differences. When tissue T(1) relaxation times are longer than the time between inversion pulses in a segmented inversion recovery pulse sequence, longitudinal magnetization does not pass through the null point. Prior to additional inversion pulses, longitudinal magnetization may have an opposite polarity. Spatial displacement of tissues in inversion recovery balanced steady-state free-precession imaging has been shown to be due to this magnetization phase change resulting from incomplete magnetization recovery. In this paper, it is shown how this phase change can be used to provide image separation. A pulse sequence parameter, the time between inversion pulses (T180), can be adjusted to provide water-fat or fluid separation. Example water-fat and fluid separation images of the head, heart, and abdomen are presented. The water-fat separation performance was investigated by comparing image intensities in short-axis divided inversion recovery technique images of the heart. Fat, blood, and fluid signal was suppressed to the background noise level. Additionally, the separation performance was not affected by main magnetic field inhomogeneities.
Collapse
Affiliation(s)
- James W Goldfarb
- Department of Research and Education, Saint Francis Hospital, Roslyn, NewYork, USA.
| |
Collapse
|
21
|
Abstract
The presence of intramyocardial fat may form a substrate for arrhythmias, and fibrofatty infiltration of the myocardium has been shown to be associated with sudden death. Therefore, noninvasive detection could have high prognostic value. Fat-water–separated imaging in the heart by MRI is a sensitive means of detecting intramyocardial fat and characterizing fibrofatty infiltration. It is also useful in characterizing fatty tumors and delineating epicardial and/or pericardial fat. Multi-echo methods for fat and water separation provide a sensitive means of detecting small concentrations of fat with positive contrast and have a number of advantages over conventional chemical-shift fat suppression. Furthermore, fat and water–separated imaging is useful in resolving artifacts that may arise due to the presence of fat. Examples of fat-water–separated imaging of the heart are presented for patients with ischemic and nonischemic cardiomyopathies, as well as general tissue classification.
Collapse
|
22
|
Hernando D, Kellman P, Haldar JP, Liang ZP. Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm. Magn Reson Med 2010; 63:79-90. [PMID: 19859956 PMCID: PMC3414226 DOI: 10.1002/mrm.22177] [Citation(s) in RCA: 185] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2008] [Accepted: 07/22/2009] [Indexed: 12/18/2022]
Abstract
Water/fat separation is a classical problem for in vivo proton MRI. Although many methods have been proposed to address this problem, robust water/fat separation remains a challenge, especially in the presence of large amplitude of static field inhomogeneities. This problem is challenging because of the nonuniqueness of the solution for an isolated voxel. This paper tackles the problem using a statistically motivated formulation that jointly estimates the complete field map and the entire water/fat images. This formulation results in a difficult optimization problem that is solved effectively using a novel graph cut algorithm, based on an iterative process where all voxels are updated simultaneously. The proposed method has good theoretical properties, as well as an efficient implementation. Simulations and in vivo results are shown to highlight the properties of the proposed method and compare it to previous approaches. Twenty-five cardiac datasets acquired on a short, wide-bore scanner with different slice orientations were used to test the proposed method, which produced robust water/fat separation for these challenging datasets. This paper also shows example applications of the proposed method, such as the characterization of intramyocardial fat.
Collapse
Affiliation(s)
- Diego Hernando
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.
| | | | | | | |
Collapse
|
23
|
Goldfarb JW, Roth M, Han J. Myocardial fat deposition after left ventricular myocardial infarction: assessment by using MR water-fat separation imaging. Radiology 2009; 253:65-73. [PMID: 19703860 DOI: 10.1148/radiol.2532082290] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively investigate the prevalence of fat deposition in chronic myocardial infarction (MI) by using magnetic resonance (MR) fat-water separation imaging with sampling of the entire left ventricular (LV) myocardium. A subsidiary aim was to determine the relationship between LV fat deposition and scar characteristics, as well as regional and global cardiac functional parameters. MATERIALS AND METHODS Twenty-five patients with LV MI were evaluated in this prospective institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study after they provided written informed consent. A 1.5-T MR system was used to perform volumetric cine, fat-sensitive, and late gadolinium-enhanced (LGE) infarct imaging. Water-fat separation was performed by using a three-point Dixon reconstruction from in- and opposed-phase black-blood gradient-echo images. Fat deposition location was compared with LGE infarct imaging by using a 17-segment model. Global and regional functional variables, LGE volumes, and fat deposition were compared by using the Pearson correlation, Student t test, and multiple regression. RESULTS A fat deposition prevalence of 68% was found in areas of chronic MI. The patients with fat deposition had larger infarctions (30.0 mL +/- 15.1 [standard deviation] vs 14.8 mL +/- 6.1; P = .002), decreased wall thickening (2.3% +/- 20.0 vs 37.8% +/- 34.4; P = .003), and impaired endocardial wall motion (2.9 mm +/- 2.0 vs 5.8 mm +/- 2.6; P = .007). The volume of fat deposition was correlated with infarct volume, LV ejection fraction, LV end-diastolic volume index, and LV end-systolic volume index. CONCLUSION There is a high prevalence of fat deposition in healed MI. It is associated with post-infarction characteristics including infarct volume, LV mass, wall thickness, wall thickening, and wall motion.
Collapse
Affiliation(s)
- James W Goldfarb
- Department of Research and Education, DeMatteis MRI, St Francis Hospital, Roslyn, NY 11576, USA.
| | | | | |
Collapse
|