1
|
Noncontrast Magnetic Resonance Angiography in the Era of Nephrogenic Systemic Fibrosis and Gadolinium Deposition. J Comput Assist Tomogr 2021; 45:37-51. [PMID: 32976265 DOI: 10.1097/rct.0000000000001074] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
ABSTRACT Gadolinium-based contrast agents for clinical magnetic resonance imaging are overall safe. However, the discovery of nephrogenic systemic fibrosis in patients with severe renal impairment and gadolinium deposition in patients receiving contrast have generated developments in contrast-free imaging of the vasculature, that is, noncontrast magnetic resonance angiography. This article presents an update on noncontrast magnetic resonance angiography techniques, with comparison to other imaging alternatives. Potential benefits and challenges to implementation, and evidence to date for various clinical applications are discussed.
Collapse
|
2
|
Stinson EG, Trzasko JD, Campeau NG, Glockner JF, Huston J, Young PM, Riederer SJ. Time-resolved contrast-enhanced MR angiography with single-echo Dixon fat suppression. Magn Reson Med 2018; 80:1556-1567. [PMID: 29488251 PMCID: PMC6097950 DOI: 10.1002/mrm.27152] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 01/26/2018] [Accepted: 02/05/2018] [Indexed: 01/07/2023]
Abstract
PURPOSE Dixon-based fat suppression has recently gained interest for dynamic contrast-enhanced MRI, but multi-echo techniques require longer scan times and reduce temporal resolution compared to single-echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single-echo Dixon imaging with high spatial and temporal resolution. THEORY AND METHODS Real-valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to ΔB0 are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat-water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8. RESULTS Single-echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast-enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single-echo Dixon work. CONCLUSION Time-resolved contrast-enhanced MRI with single-echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time-subtraction methods.
Collapse
Affiliation(s)
| | | | | | | | - John Huston
- Mayo Clinic, Department of Radiology, Rochester, MN, USA
| | | | | |
Collapse
|
3
|
Riederer SJ, Stinson EG, Weavers PT. Technical Aspects of Contrast-enhanced MR Angiography: Current Status and New Applications. Magn Reson Med Sci 2017; 17:3-12. [PMID: 28855470 PMCID: PMC5760227 DOI: 10.2463/mrms.rev.2017-0053] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
This article is based on a presentation at the meeting of the Japanese Society of Magnetic Resonance in Medicine in September 2016. The purpose is to review the technical developments which have contributed to the current status of contrast-enhanced magnetic resonance angiography (CE-MRA) and to indicate related emerging areas of study. Technical developments include MRI physics-based innovations as well as improvements in MRI engineering. These have collectively addressed not only early issues of timing and venous suppression but more importantly have led to an improvement in spatiotemporal resolution of CE-MRA of more than two orders of magnitude compared to early results. This has allowed CE-MRA to be successfully performed in virtually all vascular territories of the body. Contemporary technical areas of study include improvements in implementation of high rate acceleration, extension of high performance first-pass CE-MRA across multiple imaging stations, expanded use of compressive sensing techniques, integration of Dixon-based fat suppression into CE-MRA sequences, and application of CE-MRA sequences to dynamic-contrast-enhanced perfusion imaging.
Collapse
|
4
|
Coristine AJ, Yerly J, Stuber M. A Cylindrical, Inner Volume Selecting 2D-T2-Prep Improves GRAPPA-Accelerated Image Quality in MRA of the Right Coronary Artery. PLoS One 2016; 11:e0163618. [PMID: 27736866 PMCID: PMC5063575 DOI: 10.1371/journal.pone.0163618] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Accepted: 09/12/2016] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Two-dimensional (2D) spatially selective radiofrequency (RF) pulses may be used to excite restricted volumes. By incorporating a "pencil beam" 2D pulse into a T2-Prep, one may create a "2D-T2-Prep" that combines T2-weighting with an intrinsic outer volume suppression. This may particularly benefit parallel imaging techniques, where artefacts typically originate from residual foldover signal. By suppressing foldover signal with a 2D-T2-Prep, image quality may therefore improve. We present numerical simulations, phantom and in vivo validations to address this hypothesis. METHODS A 2D-T2-Prep and a conventional T2-Prep were used with GRAPPA-accelerated MRI (R = 1.6). The techniques were first compared in numerical phantoms, where per pixel maps of SNR (SNRmulti), noise, and g-factor were predicted for idealized sequences. Physical phantoms, with compartments doped to mimic blood, myocardium, fat, and coronary vasculature, were scanned with both T2-Preparation techniques to determine the actual SNRmulti and vessel sharpness. For in vivo experiments, the right coronary artery (RCA) was imaged in 10 healthy adults, using accelerations of R = 1,3, and 6, and vessel sharpness was measured for each. RESULTS In both simulations and phantom experiments, the 2D-T2-Prep improved SNR relative to the conventional T2-Prep, by an amount that depended on both the acceleration factor and the degree of outer volume suppression. For in vivo images of the RCA, vessel sharpness improved most at higher acceleration factors, demonstrating that the 2D-T2-Prep especially benefits accelerated coronary MRA. CONCLUSION Suppressing outer volume signal with a 2D-T2-Prep improves image quality particularly well in GRAPPA-accelerated acquisitions in simulations, phantoms, and volunteers, demonstrating that it should be considered when performing accelerated coronary MRA.
Collapse
Affiliation(s)
- Andrew J. Coristine
- Department of Radiology, University Hospital (CHUV) / University of Lausanne (UNIL), Lausanne, VD, Switzerland
- CardioVascular Magnetic Resonance (CVMR) research centre, Centre for BioMedical Imaging (CIBM), Lausanne, VD, Switzerland
| | - Jerome Yerly
- Department of Radiology, University Hospital (CHUV) / University of Lausanne (UNIL), Lausanne, VD, Switzerland
- CardioVascular Magnetic Resonance (CVMR) research centre, Centre for BioMedical Imaging (CIBM), Lausanne, VD, Switzerland
| | - Matthias Stuber
- Department of Radiology, University Hospital (CHUV) / University of Lausanne (UNIL), Lausanne, VD, Switzerland
- CardioVascular Magnetic Resonance (CVMR) research centre, Centre for BioMedical Imaging (CIBM), Lausanne, VD, Switzerland
| |
Collapse
|
5
|
Li Y, Wang H, Tkach J, Roach D, Woods J, Dumoulin C. Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation. Magn Reson Med 2015; 74:1574-86. [PMID: 25470230 PMCID: PMC4452472 DOI: 10.1002/mrm.25546] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Revised: 10/12/2014] [Accepted: 11/03/2014] [Indexed: 11/11/2022]
Abstract
PURPOSE This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS Correlation imaging is a high-speed MRI framework in which image reconstruction relies on quantification of data correlation. The presented work integrates correlation imaging with a wavelet transform technique developed originally in the field of signal and image processing. This provides a new high-speed MRI approach to motion-free data collection without motion monitoring or data segmentation. The new approach, called "wavelet-space correlation imaging", is investigated in brain imaging with involuntary motion and chest imaging with free-breathing. RESULTS Wavelet-space correlation imaging can exceed the speed limit of conventional parallel imaging methods. Using this approach with high acceleration factors (6 for brain MRI, 16 for cardiac MRI, and 8 for lung MRI), motion-free images can be generated in static brain MRI with involuntary motion and nonsegmented dynamic cardiac/lung MRI with free-breathing. CONCLUSION Wavelet-space correlation imaging enables high-speed MRI in the presence of involuntary motion or physiological dynamics without motion monitoring or data segmentation.
Collapse
Affiliation(s)
- Yu Li
- Imaging Research Center, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Hui Wang
- Imaging Research Center, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Jean Tkach
- Imaging Research Center, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - David Roach
- Imaging Research Center, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Jason Woods
- Imaging Research Center, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Charles Dumoulin
- Imaging Research Center, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| |
Collapse
|
6
|
Improved receiver arrays and optimized parallel imaging accelerations applied to time-resolved 3D fluoroscopically tracked peripheral runoff CE-MRA. Magn Reson Imaging 2015; 34:280-8. [PMID: 26523649 DOI: 10.1016/j.mri.2015.10.034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Accepted: 10/26/2015] [Indexed: 01/08/2023]
Abstract
OBJECTIVES Three-station stepping-table time-resolved 3D contrast-enhanced magnetic resonance angiography has conflicting demands in the need to limit acquisition time in proximal stations to match the speed of the advancing contrast bolus and in the distal-most station to avoid venous contamination while still providing clinically useful spatial resolution. This work describes improved receiver coil arrays which address this issue by allowing increased acceleration factors, providing increased spatial resolution per unit time. MATERIALS AND METHODS Receiver coil arrays were constructed for each station (pelvis, thigh, calf) and then integrated into a 48-element array for three-station peripheral CE-MRA. Coil element sizes and array configurations for these three stations were designed to improve SENSE-type parallel imaging taking advantage of an increase in coil count for all stations versus the previous 32 channel capability. At each station either acceleration apportionment or optimal CAIPIRINHA selection was used to choose the optimum acceleration parameters for each subject. Results were evaluated in both single- and multi-station studies. RESULTS Single-station studies showed that SENSE acceleration in the thigh station could be readily increased from R=8 to R=10, allowing reduction of the frame time from 2.5 to 2.1 s to better image the typically rapidly advancing bolus at this station. Similarly, the improved coil array for the calf station permitted acceleration increase from R=8 to R=12, providing a 4.0 vs. 5.2 s frame time. Results in three-station studies suggest an improved ability to track the contrast bolus in peripheral CE-MRA. CONCLUSIONS Modified receiver coil arrays and individualized parameter optimization have been used to provide improved acceleration at all stations in multi-station peripheral CE-MRA and provide high spatial resolution with frame times as short as 2.1 s.
Collapse
|
7
|
Riederer SJ, Haider CR, Borisch EA, Weavers PT, Young PM. Recent advances in 3D time-resolved contrast-enhanced MR angiography. J Magn Reson Imaging 2015; 42:3-22. [PMID: 26032598 DOI: 10.1002/jmri.24880] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2014] [Accepted: 12/31/2014] [Indexed: 11/11/2022] Open
Abstract
Contrast-enhanced magnetic resonance angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3-4 mm spatial resolution with acquisition times in the 30-second range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution 3D time-resolved studies. The purpose of this work is to describe how this has been accomplished. Specific technical enablers have been: improved gradients allowing reduced repetition times, improved k-space sampling and reconstruction methods, parallel acquisition, particularly in two directions, and improved and higher count receiver coil arrays. These have collectively made high-resolution time-resolved studies readily available for many anatomic regions. Depending on the application, ∼1 mm isotropic resolution is now possible with frame times of several seconds. Clinical applications of time-resolved CE-MRA are briefly reviewed.
Collapse
|
8
|
Weavers PT, Borisch EA, Riederer SJ. Selection and evaluation of optimal two-dimensional CAIPIRINHA kernels applied to time-resolved three-dimensional CE-MRA. Magn Reson Med 2014; 73:2234-42. [PMID: 25046590 DOI: 10.1002/mrm.25366] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 06/23/2014] [Accepted: 06/25/2014] [Indexed: 12/15/2022]
Abstract
PURPOSE To develop and validate a method for choosing the optimal two-dimensional CAIPIRINHA kernel for subtraction contrast-enhanced MR angiography (CE-MRA) and estimate the degree of image quality improvement versus that of some reference acceleration parameter set at R ≥ 8. METHODS A metric based on patient-specific coil calibration information was defined for evaluating optimality of CAIPIRINHA kernels as applied to subtraction CE-MRA. Evaluation in retrospective studies using archived coil calibration data from abdomen, calf, foot, and hand CE-MRA exams was accomplished with an evaluation metric comparing the geometry factor (g-factor) histograms. Prospective calf, foot, and hand CE-MRA studies were evaluated with vessel signal-to-noise ratio (SNR). RESULTS Retrospective studies show g-factor improvement for the selected CAIPIRINHA kernels was significant in the feet, moderate in the abdomen, and modest in the calves and hands. Prospective CE-MRA studies using optimal CAIPIRINHA show reduced noise amplification with identical acquisition time in studies of the feet, with minor improvements in the hands and calves. CONCLUSION A method for selection of the optimal CAIPIRINHA kernel for high (R ≥ 8) acceleration CE-MRA exams given a specific patient and receiver array was demonstrated. CAIPIRINHA optimization appears valuable in accelerated CE-MRA of the feet and to a lesser extent in the abdomen.
Collapse
Affiliation(s)
- Paul T Weavers
- Department of Radiology, MR Research Laboratory, Mayo Clinic, Rochester, Minnesota, USA
| | - Eric A Borisch
- Department of Radiology, MR Research Laboratory, Mayo Clinic, Rochester, Minnesota, USA
| | - Stephen J Riederer
- Department of Radiology, MR Research Laboratory, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
9
|
Johnson CP, Weavers PT, Borisch EA, Grimm RC, Hulshizer TC, LaPlante CC, Rossman PJ, Glockner JF, Young PM, Riederer SJ. Three-station three-dimensional bolus-chase MR angiography with real-time fluoroscopic tracking. Radiology 2014; 272:241-51. [PMID: 24635676 DOI: 10.1148/radiol.14131603] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine the feasibility of using real-time fluoroscopic tracking for bolus-chase magnetic resonance (MR) angiography of peripheral vasculature to image three stations from the aortoiliac bifurcation to the pedal arteries. MATERIALS AND METHODS This prospective study was institutional review board approved and HIPAA compliant. Eight healthy volunteers (three men; mean age, 48 years; age range, 30-81 years) and 13 patients suspected of having peripheral arterial disease (five men; mean age, 67 years; age range, 47-81 years) were enrolled and provided informed consent. All subjects were imaged with the fluoroscopic tracking MR angiographic protocol. Ten patients also underwent a clinical computed tomographic (CT) angiographic runoff examination. Two readers scored the MR angiographic studies for vessel signal intensity and sharpness and presence of confounding artifacts and venous contamination at 35 arterial segments. Mean aggregate scores were assessed. The paired MR angiographic and CT angiographic studies also were scored for visualization of disease, reader confidence, and overall diagnostic quality and were compared by using a Wilcoxon signed rank test. RESULTS Real-time fluoroscopic tracking performed well technically in all studies. Vessel segments were scored good to excellent in all but the following categories: For vessel signal intensity and sharpness, the abdominal aorta, iliac arteries, distal plantar arteries, and plantar arch were scored as fair to good; and for presence of confounding artifacts, the abdominal aorta and iliac arteries were scored as fair. The MR angiograms and CT angiograms did not differ significantly in any scoring category (reader 1: P = .50, .39, and .39; reader 2: P = .41, .61, and .33, respectively). CT scores were substantially better in 20% (four of 20) and 25% (five of 20) of the pooled evaluations for the visualization of disease and overall image quality categories, respectively, versus 5% (one of 20) for MR scores in both categories. CONCLUSION Three-station bolus-chase MR angiography with real-time fluoroscopic tracking provided high-spatial-resolution arteriograms of the peripheral vasculature, enabled precise triggering of table motion, and compared well with CT angiograms.
Collapse
Affiliation(s)
- Casey P Johnson
- From the Department of Radiology, University of Iowa, Iowa City, Iowa (C.P.J.); and MR Research Laboratory and Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (P.T.W., E.A.B., R.C.G., T.C.H., C.C.L., P.J.R., J.F.G., P.M.Y., S.J.R.)
| | | | | | | | | | | | | | | | | | | |
Collapse
|