1
|
McDowell AR, Zambreanu L, Salhab HA, Doherty CM, Bridgen P, Lally P, Shah S, Huo Z, Wastling SJ, Yousry T, Morrow J, Thornton JS, Lunn MP. Initial findings using high-resolution magnetic resonance imaging for visualisation of the sural nerve and surrounding anatomy in healthy volunteers at 7 Tesla. J Peripher Nerv Syst 2024; 29:368-375. [PMID: 39056278 DOI: 10.1111/jns.12645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 06/27/2024] [Accepted: 07/01/2024] [Indexed: 07/28/2024]
Abstract
BACKGROUND AND AIMS Histopathological diagnosis is the gold standard in many acquired inflammatory, infiltrative and amyloid based peripheral nerve diseases and a sensory nerve biopsy of sural or superficial peroneal nerve is favoured where a biopsy is deemed necessary. The ability to determine nerve pathology by high-resolution imaging techniques resolving anatomy and imaging characteristics might improve diagnosis and obviate the need for biopsy in some. The sural nerve is anatomically variable and occasionally adjacent vessels can be sent for analysis in error. Knowing the exact position and relationships of the nerve prior to surgery could be clinically useful and thus reliably resolving nerve position has some utility. METHODS 7T images of eight healthy volunteers' (HV) right ankle were acquired in a pilot study using a double-echo in steady-state sequence for high-resolution anatomy images. Magnetic Transfer Ratio images were acquired of the same area. Systematic scoring of the sural, tibial and deep peroneal nerve around the surgical landmark 7 cm from the lateral malleolus was performed (number of fascicles, area in voxels and mm2, diameter and location relative to nearby vessels and muscles). RESULTS The sural and tibial nerves were visualised in the high-resolution double-echo in steady-state (DESS) image in all HV. The deep peroneal nerve was not always visualised at level of interest. The MTR values were tightly grouped except in the sural nerve where the nerve was not visualised in two HV. The sural nerve location was found to be variable (e.g., lateral or medial to, or crossing behind, or found positioned directly posterior to the saphenous vein). INTERPRETATION High-resolution high-field images have excellent visualisation of the sural nerve and would give surgeons prior knowledge of the position before surgery. Basic imaging characteristics of the sural nerve can be acquired, but more detailed imaging characteristics are not easily evaluable in the very small sural and further developments and specific studies are required for any diagnostic utility at 7T.
Collapse
Affiliation(s)
| | - Laura Zambreanu
- UCL Queen Square Institute of Neurology, London, UK
- Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK
| | | | | | - Philippa Bridgen
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- London Collaborative Ultra High Field System (LoCUS), Kings College London, London, UK
- Guys and St Thomas' NHS Foundation Trust, Kings College London, London, UK
| | | | - Sachit Shah
- UCL Queen Square Institute of Neurology, London, UK
- Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK
| | - Zimu Huo
- Imperial College London, London, UK
| | - Stephen J Wastling
- Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK
| | - Tarek Yousry
- UCL Queen Square Institute of Neurology, London, UK
- Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK
| | - Jasper Morrow
- UCL Queen Square Institute of Neurology, London, UK
- Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK
| | - John S Thornton
- UCL Queen Square Institute of Neurology, London, UK
- Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK
| | - Michael P Lunn
- UCL Queen Square Institute of Neurology, London, UK
- Centre for Neuromuscular Diseases, National Hospital for Neurology and Neurosurgery, London, UK
- NIHR University College London Hospitals Biomedical Research Centre, Research & Development, London, UK
| |
Collapse
|
2
|
Nuñez-Peralta C, Montesinos P, Alonso-Jiménez A, Alonso-Pérez J, Reyes-Leiva D, Sánchez-González J, Llauger-Roselló J, Segovia S, Belmonte I, Pedrosa I, Martínez-Noguera A, Matellini-Mosca B, Walter G, Díaz-Manera J. Magnetization Transfer Ratio in Lower Limbs of Late Onset Pompe Patients Correlates With Intramuscular Fat Fraction and Muscle Function Tests. Front Neurol 2021; 12:634766. [PMID: 33796064 PMCID: PMC8009135 DOI: 10.3389/fneur.2021.634766] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Accepted: 02/01/2021] [Indexed: 11/23/2022] Open
Abstract
Objectives: Magnetization transfer (MT) imaging exploits the interaction between bulk water protons and protons contained in macromolecules to induce signal changes through a special radiofrequency pulse. MT detects muscle damage in patients with neuromuscular conditions, such as limb-girdle muscular dystrophies or Charcot-Marie-Tooth disease, which are characterized by progressive fiber loss and replacement by fatty tissue. In Pompe disease, in which there is, in addition, an accumulation of glycogen inside the muscle fibers, MT has not been tested yet. Our aim is to estimate MT ratio (MTR) in the skeletal muscle of these patients and correlate it with intramuscular fat fraction (FF) and results of muscle function tests. Methods: We obtained two-point axial Dixon and Dixon-MT sequences of the right thigh on a 1.5 Teslas MRI scanner in 60 individuals, including 29 late onset Pompe disease patients, 2 patients with McArdle disease, and 29 age and sex matched healthy controls. FF and MTR were estimated. Muscle function using several muscle function tests, including quantification of muscle strength, timed test quality of life scales, conventional spirometry obtaining forced vital capacity while sitting and in the supine position, were assessed in all patients. Results: MTR was significantly lower in Pompe patients compared with controls (45.5 ± 8.5 vs. 51.7 ± 2.3, Student T-test, p < 0.05). There was a negative correlation between the MTR and FF muscles studied (correlation coefficient: −0.65, Spearman test: p < 0.05). MTR correlated with most of the muscle function test results. We analyzed if there was any difference in MTR values between Pompe patients and healthy controls in those muscles that did not have an increase in fat, a measure that could be related to the presence of glycogen in skeletal muscles, but we did not identify significant differences except in the adductor magnus muscle (48.4 ± 3.6 in Pompe vs. 51 ± 1.3 in healthy controls, Student T-test = 0.023). Conclusions: MTR is a sensitive tool to identify muscle loss in patients with Pompe disease and shows a good correlation with muscle function tests. Therefore, the MT technique can be useful in monitoring muscle degeneration in Pompe disease in clinical trials or natural history studies.
Collapse
Affiliation(s)
| | | | - Alicia Alonso-Jiménez
- Neuromuscular Reference Center, Neurology Department, University Hospital of Antwerp, Edegem, Belgium
| | - Jorge Alonso-Pérez
- Neuromuscular Disorders Unit, Neurology Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - David Reyes-Leiva
- Neuromuscular Disorders Unit, Neurology Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | | | | | - Sonia Segovia
- Neuromuscular Disorders Unit, Neurology Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.,Centro de Investigación Biomédica en Red de Enfermedades Raras (CIBERER), Madrid, Spain
| | - Izaskun Belmonte
- Rehabilitation Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Irene Pedrosa
- Rehabilitation Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | | | | | - Glenn Walter
- Department of Physiology and Functional Genomics, University of Florida, Gainesville, FL, United States
| | - Jordi Díaz-Manera
- Neuromuscular Disorders Unit, Neurology Department, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.,Centro de Investigación Biomédica en Red de Enfermedades Raras (CIBERER), Madrid, Spain.,John Walton Muscular Dystrophy Research Center, Newcastle University, Newcastle upon Tyne, United Kingdom
| |
Collapse
|
3
|
Ercan E, Varma G, Dimitrov IE, Xi Y, Pinho MC, Yu FF, Zhang S, Wang X, Madhuranthakam AJ, Lenkinski RE, Alsop DC, Vinogradov E. Combining inhomogeneous magnetization transfer and multipoint Dixon acquisition: Potential utility and evaluation. Magn Reson Med 2020; 85:2136-2144. [PMID: 33107146 PMCID: PMC7821205 DOI: 10.1002/mrm.28571] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 09/08/2020] [Accepted: 10/06/2020] [Indexed: 11/08/2022]
Abstract
PURPOSE The recently introduced inhomogeneous magnetization transfer (ihMT) method has predominantly been applied for imaging the central nervous system. Future applications of ihMT, such as in peripheral nerves and muscles, will involve imaging in the vicinity of adipose tissues. This work aims to systematically investigate the partial volume effect of fat on the ihMT signal and to propose an efficient fat-separation method that does not interfere with ihMT measurements. METHODS First, the influence of fat on ihMT signal was studied using simulations. Next, the ihMT sequence was combined with a multi-echo Dixon acquisition for fat separation. The sequence was tested in 9 healthy volunteers using a 3T human scanner. The ihMT ratio (ihMTR) values were calculated in regions of interest in the brain and the spinal cord using standard acquisition (no fat saturation), water-only, in-phase, and out-of-phase reconstructions. The values obtained were compared with a standard fat suppression method, spectral presaturation with inversion recovery. RESULTS Simulations showed variations in the ihMTR values in the presence of fat, depending on the TEs used. The IhMTR values in the brain and spinal cord derived from the water-only ihMT multi-echo Dixon images were in good agreement with values from the unsuppressed sequence. The ihMT-spectral presaturation with inversion recovery combination resulted in 24%-35% lower ihMTR values compared with the standard non-fat-suppressed acquisition. CONCLUSION The presence of fat within a voxel affects the ihMTR calculations. The IhMT multi-echo Dixon method does not compromise the observable ihMT effect and can potentially be used to remove fat influence in ihMT.
Collapse
Affiliation(s)
- Ece Ercan
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Gopal Varma
- Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Radiology, Boston, MA, USA
| | - Ivan E Dimitrov
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA.,Philips Healthcare, Gainesville, FL, USA
| | - Yin Xi
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Department of Population and Data Sciences, UT Southwestern Medical Center, Dallas, TX, USA
| | - Marco C Pinho
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Fang F Yu
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | - Shu Zhang
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Department of Cancer Systems Imaging, UT MD Anderson Cancer Center, Houston, TX, USA
| | - Xinzeng Wang
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Global MR Application and Workflow, GE Healthcare, Houston, TX, USA
| | - Ananth J Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - Robert E Lenkinski
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| | - David C Alsop
- Division of MR Research, Beth Israel Deaconess Medical Center, Harvard Medical School, Radiology, Boston, MA, USA
| | - Elena Vinogradov
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
4
|
Outteryck O, Lopes R, Drumez É, Labreuche J, Lannoy J, Hadhoum N, Boucher J, Vermersch P, Zedet M, Pruvo JP, Zéphir H, Leclerc X. Optical coherence tomography for detection of asymptomatic optic nerve lesions in clinically isolated syndrome. Neurology 2020; 95:e733-e744. [DOI: 10.1212/wnl.0000000000009832] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Accepted: 02/06/2020] [Indexed: 12/24/2022] Open
Abstract
ObjectiveTo evaluate the ability of intereye retinal thickness difference (IETD) measured by optical coherence tomography (OCT) to detect asymptomatic optic nerve involvement in clinically isolated syndrome (CIS).MethodsWe conducted a cross-sectional study of patients who recently presented a CIS (≤4.5 months). All patients underwent OCT and brain/optic nerve MRI. Optic nerve involvement was defined clinically (episode of optic neuritis [ON] or not) and radiologically (optic nerve hypersignal on 3D double inversion recovery [3D-DIR]). We evaluated the sensitivity and specificity of previously published IETD thresholds and report the observed optimal thresholds for identifying symptomatic optic nerve involvement but also for identifying asymptomatic optic nerve involvement (optic nerve hypersignal without ON history). Primary outcomes were ganglion cell–inner plexiform layer (GC-IPL) and peripapillary retinal nerve fiber layer IETD.ResultsThe study group consisted of 130 patients. In the CIS with ON group, 3D-DIR showed a hypersignal in all 41 symptomatic optic nerves and in 11 asymptomatic optic nerves. In the CIS without ON group, 3D-DIR showed a unilateral optic nerve hypersignal in 22 patients and a bilateral optic nerve hypersignal in 7 patients. For the detection of symptomatic and asymptomatic optic nerve lesion, GC-IPL IETD had better performance. We found an optimal GC-IPL IETD threshold ≥2.83 µm (sensitivity 88.2, specificity 83.3%) for the detection of symptomatic lesions and an optimal GC-IPL IETD ≥1.42 µm (sensitivity 89.3%, specificity 72.6%) for the detection of asymptomatic lesions.ConclusionsDetection of asymptomatic optic nerve lesions in CIS requires lower IETD thresholds than previously reported. GC-IPL IETD represents an alternative biomarker to MRI for the detection of asymptomatic optic nerve lesions.Classification of evidenceThis study provides Class I evidence that OCT accurately identifies asymptomatic optic nerve involvement in patients with CIS.
Collapse
|
5
|
London F, Zéphir H, Drumez E, Labreuche J, Hadhoum N, Lannoy J, Hodel J, Vermersch P, Pruvo JP, Leclerc X, Outteryck O. Optical coherence tomography: a window to the optic nerve in clinically isolated syndrome. Brain 2019; 142:903-915. [PMID: 30847470 DOI: 10.1093/brain/awz038] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 12/19/2018] [Accepted: 12/31/2018] [Indexed: 12/25/2022] Open
Abstract
In this study, we aimed to evaluate the association of asymptomatic optic nerve demyelinating lesion in patients presenting a clinically isolated syndrome with the asymptomatic retinal neuro-axonal loss previously reported at clinically isolated syndrome. We prospectively recruited 66 patients presenting a clinically isolated syndrome and 66 healthy control subjects matched according to age and gender. All patients underwent brain magnetic resonance imaging including 3D-double inversion recovery (DIR) sequence, optical coherence tomography examination and visual function evaluation, at 2.5-4.5 months after CIS. Evaluation criteria were presence and length of optic nerve DIR hypersignal, retinal layers (including ganglion cell inner plexiform layer and inner nuclear layer) thickness/volume, and low contrast monocular vision acuity (number of letters correctly identified). All clinically isolated syndrome eyes with past history of optic neuritis (CIS-ON) presented an optic nerve DIR hypersignal. We observed asymptomatic optic nerve DIR hypersignal in 22.2% of clinically isolated syndrome eyes without optic neuritis (CIS-NON). In comparison with healthy control, GCIPL volume (in mm3) was significantly lower in CIS-ON eyes [β (95% confidence interval, CI) = -0.121 (-0.168 to -0.074); P < 0.0001], and to a lesser extent in CIS-NON [β (95% CI) = -0.023 (-0.039 to -0.008); P = 0.004]. In comparison to healthy controls, eyes with asymptomatic optic nerve DIR hypersignal presented significantly lower macular ganglion cell inner plexiform layer volume [β (95% CI) = -0.043 (-0.068 to -0.019); P = 0.001], and eyes without did not [β (95% CI) = -0.016 (-0.034 to 0.003); P = 0.083]. Among CIS-NON, macular ganglion cell inner plexiform layer volume decrease was associated with asymptomatic optic nerve DIR hypersignal independently of optic radiations T2 lesions and primary visual cortex volumes (P = 0.012). Symptomatic optic nerve DIR hypersignal were significantly longer (13.8 ± 6.7 mm) than asymptomatic optic nerve hypersignal (10.0 ± 5.5 mm; P = 0.047). Length of optic nerve DIR hypersignal was significantly associated with thinner inner retinal layers (P ≤ 0.001), thicker inner nuclear layer (P = 0.017) and lower low contrast monocular vision acuity (P < 0.05). Compared to healthy control, low contrast monocular vision acuity was significantly lower in CIS-ON eyes (P < 0.0001) and CIS-NON eyes with (P = 0.03) or without asymptomatic optic nerve DIR hypersignal (P = 0.0005). Asymptomatic demyelinating optic nerve DIR hypersignal at the earliest clinical stage of multiple sclerosis is frequent and associated with asymptomatic retinal neuro-axonal loss reported at clinically isolated syndrome stage. Length of optic nerve DIR hypersignal is a biomarker of retinal neuro-axonal loss and visual disability at clinically isolated syndrome stage. Visual disability of clinically isolated syndrome eyes without clinical and subclinical optic nerve involvement might be due to missed optic nerve lesions on MRI. At the earliest clinical stage of multiple sclerosis, our results support considering optical coherence tomography as a window to the optic nerve rather than to the brain.
Collapse
Affiliation(s)
- Frédéric London
- University of Lille (UMR995), Department of Neurology, Roger Salengro Hospital, Lille, France
| | - Hélène Zéphir
- University of Lille (UMR995), Department of Neurology, Roger Salengro Hospital, Lille, France
| | - Elodie Drumez
- University of Lille, CHU Lille, EA 2694 - Santé publique : épidémiologie et qualité des soins, F-59000 Lille, France
| | - Julien Labreuche
- University of Lille, CHU Lille, EA 2694 - Santé publique : épidémiologie et qualité des soins, F-59000 Lille, France
| | - Nawal Hadhoum
- University of Lille (UMR995), Department of Neurology, Roger Salengro Hospital, Lille, France
| | - Julien Lannoy
- University of Lille (UMR995), Department of Neurology, Roger Salengro Hospital, Lille, France
| | - Jérôme Hodel
- University of Lille (UMR1171), Department of Neuroradiology, Roger Salengro Hospital, Lille, France.,University of Paris Est Créteil, Department of Neuroradiology, Hopital Henri Mondor, Créteil, Paris, France
| | - Patrick Vermersch
- University of Lille (UMR995), Department of Neurology, Roger Salengro Hospital, Lille, France
| | - Jean-Pierre Pruvo
- University of Lille (UMR1171), Department of Neuroradiology, Roger Salengro Hospital, Lille, France
| | - Xavier Leclerc
- University of Lille (UMR1171), Department of Neuroradiology, Roger Salengro Hospital, Lille, France
| | - Olivier Outteryck
- University of Lille (UMR1171), Department of Neuroradiology, Roger Salengro Hospital, Lille, France
| |
Collapse
|
6
|
Preoperative Evaluation of Pancreatic Fibrosis and Lipomatosis: Correlation of Magnetic Resonance Findings With Histology Using Magnetization Transfer Imaging and Multigradient Echo Magnetic Resonance Imaging. Invest Radiol 2019; 53:720-727. [PMID: 30247172 DOI: 10.1097/rli.0000000000000496] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVES The purpose of this study was to evaluate the diagnostic performance of magnetization transfer (MT) imaging and multigradient echo magnetic resonance imaging (MRI) to quantify pancreatic fibrosis and lipomatosis in patients before pancreatoduodenectomy for postoperative risk stratification with histopathology as the reference standard. MATERIALS AND METHODS Twenty-four patients (age, 68 ± 8 years, 16 males) prospectively underwent quantitative MT imaging using a 2-dimensional gradient echo sequence with and without MT prepulse and multigradient echo imaging on a 3 T MRI 1 day before pancreatoduodenectomy due to adenocarcinoma of the pancreatic head region (n = 20), neuroendocrine tumor (n = 3), or intraductal papillary mucinous neoplasm (n = 1). Magnetization transfer ratio (MTR) and proton density fat fraction (PDFF) were measured in pancreatic tail (PT) and at the resection margin (RM). Histopathologically, pancreatic fibrosis was graded as mild, moderate, or severe (F1-F3), lipomatosis was graded as 0% to 10%, 11% to 30%, and greater than 30% fat deposition (L1-L3). In addition, MTR and histopathologic fibrosis was assessed in pancreatic adenocarcinoma. Mann-Whitney U test and Spearman correlation were used. RESULTS Patients with advanced pancreatic fibrosis (F3) showed a significantly higher MTR compared with the F1 group at the RM and PT (38 ± 4 vs 32.3 ± 1.6, P = 0.018 and 39.7 ± 5.5 vs 31.2 ± 1.7, P = 0.001). Spearman correlation coefficient of MTR and fibrosis grade was r = 0.532 (P = 0.011) and 0.554 (P = 0.008), respectively. Pancreatic parenchyma with advanced fat deposition (L2-L3) showed significantly higher PDFF compared with lipomatosis grade L1 (RM: P = 0.002 and PT: P = 0.001). Proton density fat fraction of pancreatic parenchyma exhibited a moderate and significant correlation with histopathologic lipomatosis grade (RM: r = 0.668 and PT: r = 0.707, P < 0.001). Magnetization transfer ratio was significantly higher in pancreatic adenocarcinoma compared with pancreatic parenchyma (44 ± 5.5 vs 36.0 ± 4.4 and 37.4 ± 5.4, P = 0.004). CONCLUSIONS Multiparametric MRI of the pancreas including MTR and PDFF maps may provide quantitative and noninvasive information on pancreatic fibrosis and lipomatosis before surgery.
Collapse
|
7
|
Samsonov A, Liu F, Velikina JV. Resolving estimation uncertainties of chemical shift encoded fat-water imaging using magnetization transfer effect. Magn Reson Med 2019; 82:202-212. [PMID: 30847974 DOI: 10.1002/mrm.27709] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 01/30/2019] [Accepted: 02/04/2019] [Indexed: 12/17/2022]
Abstract
PURPOSE B0 field inhomogeneity may cause significant errors in chemical shift encoding-based fat-water (F/W) separation. We describe a new approach to improve its robustness using novel B0 field map pre-estimation. METHODS Our method exploits insensitivity of fat to magnetization transfer effect, which allows generating fat-insensitive B0 field priors with full or partial spatial support using a low-resolution magnetization transfer-weighted scan. The full prior can be employed by most F/W separation methods for initialization or data demodulation. We also propose a modified region-growing algorithm in which the partial prior is utilized for its initial seeding. RESULTS The magnetization transfer-based B0 priors significantly reduced F/W errors of three representative F/W separation methods in all cases. In cases with moderate B0 inhomogeneity, the full prior allowed error-free separation even with basic, voxel-independent processing. When coupled with methods exploiting B0 field smoothness, it significantly improved separation accuracy even in the presence of strong inhomogeneities. Seeding the region-growing with the partial prior significantly improved performance of F/W separation, including cases with spatially disconnected tissues. CONCLUSION Magnetization transfer-based B0 field pre-estimation provides valuable prior information for F/W separation, which may significantly improve its robustness at the expense of nominal (< 5%-10%) scan time increase.
Collapse
Affiliation(s)
- Alexey Samsonov
- Department of Radiology, University of Wisconsin, Madison, Wisconsin
| | - Fang Liu
- Department of Radiology, University of Wisconsin, Madison, Wisconsin
| | - Julia V Velikina
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin
| |
Collapse
|
8
|
Ma YJ, Tadros A, Du J, Chang EY. Quantitative two-dimensional ultrashort echo time magnetization transfer (2D UTE-MT) imaging of cortical bone. Magn Reson Med 2017; 79:1941-1949. [PMID: 28776754 DOI: 10.1002/mrm.26846] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 06/28/2017] [Accepted: 06/30/2017] [Indexed: 01/19/2023]
Abstract
PURPOSE To investigate quantitative 2D ultrashort echo time magnetization transfer (UTE-MT) imaging in ex vivo bovine cortical bone and in vivo human tibial cortical bone. METHODS Data were acquired from five fresh bovine cortical bone samples and five healthy volunteer tibial cortical bones using a 2D UTE-MT sequence on a clinical 3T scanner. The 2D UTE-MT sequence used four or five MT powers with five frequency offsets. Results were analyzed with a two-pool quantitative MT model, providing measurements of macromolecular fraction (f), macromolecular proton transverse relaxation times (T2m ), proton exchange rates from water/macromolecular to the macromolecular/water pool (RM0m /RM0w ), and spin-lattice relaxation rate of water pool (R1w ). A sequential air-drying study for a small bovine cortical bone chip was used to investigate whether above MT modeling parameters were sensitive to the water loss. RESULTS Mean fresh bovine cortical bone values for f, T2m , R1w , RM0m , and RM0w were 59.9 ± 7.3%, 14.6 ± 0.3 μs, 9.9 ± 2.4 s-1 , 17.9 ± 3.6 s-1 , and 11.8 ± 2.0 s-1 , respectively. Mean in vivo human cortical bone values for f, T2m , R1w , RM0m and RM0w were 54.5 ± 4.9%, 15.4 ± 0.6 μs, 8.9 ± 1.1 s-1 , 11.5 ± 3.5 s-1 , and 9.5 ± 1.9 s-1 , respectively. The sequential air-drying study shows that f, RM0m , and R1w were increased with longer drying time. CONCLUSION UTE-MT two-pool modeling provides novel and useful quantitative information for cortical bone. Magn Reson Med 79:1941-1949, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Ya-Jun Ma
- Department of Radiology, University of California, San Diego, San Diego, California, USA
| | - Anthony Tadros
- Department of Radiology, University of California, San Diego, San Diego, California, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, San Diego, California, USA
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, San Diego, California, USA.,Radiology Service, VA San Diego Healthcare System, San Diego, California, USA
| |
Collapse
|