1
|
Toupin S, Pezel T, Bustin A, Cochet H. Whole-Heart High-Resolution Late Gadolinium Enhancement: Techniques and Clinical Applications. J Magn Reson Imaging 2021; 55:967-987. [PMID: 34155715 PMCID: PMC9292698 DOI: 10.1002/jmri.27732] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 04/13/2021] [Accepted: 04/14/2021] [Indexed: 12/15/2022] Open
Abstract
In cardiovascular magnetic resonance, late gadolinium enhancement (LGE) has become the cornerstone of myocardial tissue characterization. It is widely used in clinical routine to diagnose and characterize the myocardial tissue in a wide range of ischemic and nonischemic cardiomyopathies. The recent growing interest in imaging left atrial fibrosis has led to the development of novel whole‐heart high‐resolution late gadolinium enhancement (HR‐LGE) techniques. Indeed, conventional LGE is acquired in multiple breath‐holds with limited spatial resolution: ~1.4–1.8 mm in plane and 6–8 mm slice thickness, according to the Society for Cardiovascular Magnetic Resonance standardized guidelines. Such large voxel size prevents its use in thin structures such as the atrial or right ventricular walls. Whole‐heart 3D HR‐LGE images are acquired in free breathing to increase the spatial resolution (up to 1.3 × 1.3 × 1.3 mm3) and offer a better detection and depiction of focal atrial fibrosis. The downside of this increased resolution is the extended scan time of around 10 min, which hampers the spread of HR‐LGE in clinical practice. Initially introduced for atrial fibrosis imaging, HR‐LGE interest has evolved to be a tool to detect small scars in the ventricles and guide ablation procedures. Indeed, the detection of scars, nonvisible with conventional LGE, can be crucial in the diagnosis of myocardial infarction with nonobstructed coronary arteries, in the detection of the arrhythmogenic substrate triggering ventricular arrhythmia, and improve the confidence of clinicians in the challenging diagnoses such as the arrhythmogenic right ventricular cardiomyopathy. HR‐LGE also offers a precise visualization of left ventricular scar morphology that is particularly useful in planning ablation procedures and guiding them through the fusion of HR‐LGE images with electroanatomical mapping systems. In this narrative review, we attempt to summarize the technical particularities of whole‐heart HR‐LGE acquisition and provide an overview of its clinical applications with a particular focus on the ventricles.
Collapse
Affiliation(s)
- Solenn Toupin
- Siemens Healthcare France, Saint-Denis, France.,IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Bordeaux, France.,Université de Bordeaux, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France.,INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France
| | - Théo Pezel
- Division of Cardiology, Johns Hopkins University, Baltimore, Maryland, USA.,Department of Cardiology, Lariboisiere Hospital, APHP, University of Paris, Paris, France
| | - Aurélien Bustin
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Bordeaux, France.,Université de Bordeaux, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France.,INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France.,Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Hubert Cochet
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Bordeaux, France.,Université de Bordeaux, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France.,INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, Bordeaux, France.,Bordeaux University Hospital (CHU), Pessac, France
| |
Collapse
|
2
|
Zhang L, Lai P, Roifman I, Pop M, Wright GA. Multi-contrast volumetric imaging with isotropic resolution for assessing infarct heterogeneity: Initial clinical experience. NMR IN BIOMEDICINE 2020; 33:e4253. [PMID: 32026547 DOI: 10.1002/nbm.4253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2018] [Revised: 11/14/2019] [Accepted: 12/05/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND To evaluate accelerated multi-contrast volumetric imaging with isotropic resolution reconstructed using low-rank and spatially varying edge-preserving constrained compressed sensing parallel imaging reconstruction (CP-LASER), for assessing infarct heterogeneity on post-infarction patients as a precursor to studies of utility for predicting ventricular arrhythmias. METHODS Eleven patients with prior myocardial infarction were included in the study. All subjects underwent cardiovascular magnetic resonance (CMR) scans including conventional two-dimensional late gadolinium enhancement (2D LGE) and three-dimensional multi-contrast late enhancement (3D MCLE) post-contrast. The extent of the infarct core and peri-infarct gray zone of a limited mid-ventricular slab were derived respectively by analyzing MCLE images with an isotropic resolution of 2.2 mm and an anisotropic resolution of 2.2×2.2×8.8 mm 3 , and LGE images with a resolution of 1.37×2.7×8 mm 3 ; the respective measures across all subjects were statistically compared. RESULTS Using 3D MCLE, the infarct core size measured with isotropic resolution was similar to that measured with anisotropic resolution, while the peri-infarct gray zone size measured with isotropic resolution was smaller than that measured with anisotropic resolution ( p<0.001 , Cohen's dz=1.33 ). Isotropic 3D MCLE yielded a significantly smaller measure of the peri-infarct gray zone size than conventional 2D LGE ( p=0.0016 , Cohen's dz=1.20 ). Overall, we have successfully shown the utility of isotropic 3D MCLE in a pilot patient study. Our results suggest that smaller voxels lead to more accurate differentiation between isotropic 3D MCLE-derived gray zone and core infarct because of diminished partial volume effect. CONCLUSION The CP-LASER accelerated 3D MCLE with isotropic resolution can be used in patients and yields excellent delineation of infarct and peri-infarct gray zone characteristics.
Collapse
Affiliation(s)
- Li Zhang
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Peng Lai
- Global Applied Science Laboratory, GE Healthcare, Menlo Park, California, USA
| | - Idan Roifman
- Schulich Heart Research Program, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Mihaela Pop
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
- Schulich Heart Research Program, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Graham A Wright
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
- Schulich Heart Research Program, Sunnybrook Research Institute, Toronto, Ontario, Canada
| |
Collapse
|
3
|
Baehr A, Klymiuk N, Kupatt C. Evaluating Novel Targets of Ischemia Reperfusion Injury in Pig Models. Int J Mol Sci 2019; 20:E4749. [PMID: 31557793 PMCID: PMC6801853 DOI: 10.3390/ijms20194749] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 09/19/2019] [Accepted: 09/22/2019] [Indexed: 12/12/2022] Open
Abstract
Coronary heart diseases are of high relevance for health care systems in developed countries regarding patient numbers and costs. Disappointingly, the enormous effort put into the development of innovative therapies and the high numbers of clinical studies conducted are counteracted by the low numbers of therapies that become clinically effective. Evidently, pre-clinical research in its present form does not appear informative of the performance of treatments in the clinic and, even more relevant, it appears that there is hardly any consent about how to improve the predictive capacity of pre-clinical experiments. According to the steadily increasing relevance that pig models have gained in biomedical research in the recent past, we anticipate that research in pigs can be highly predictive for ischemia-reperfusion injury (IRI) therapies as well. Thus, we here describe the significance of pig models in IRI, give an overview about recent developments in evaluating such models by clinically relevant methods and present the latest insight into therapies applied to pigs under IRI.
Collapse
Affiliation(s)
- Andrea Baehr
- Klinikum Rechts der Isar, Internal Medicine I, Technical University of Munich, 81675 Munich, Germany.
- German Centre for Cardiovascular Research, Munich Heart Alliance, 80802 Munich, Germany.
| | - Nikolai Klymiuk
- Klinikum Rechts der Isar, Internal Medicine I, Technical University of Munich, 81675 Munich, Germany.
- German Centre for Cardiovascular Research, Munich Heart Alliance, 80802 Munich, Germany.
| | - Christian Kupatt
- Klinikum Rechts der Isar, Internal Medicine I, Technical University of Munich, 81675 Munich, Germany.
- German Centre for Cardiovascular Research, Munich Heart Alliance, 80802 Munich, Germany.
| |
Collapse
|
4
|
Bustin A, Lima da Cruz G, Jaubert O, Lopez K, Botnar RM, Prieto C. High-dimensionality undersampled patch-based reconstruction (HD-PROST) for accelerated multi-contrast MRI. Magn Reson Med 2019; 81:3705-3719. [PMID: 30834594 PMCID: PMC6646908 DOI: 10.1002/mrm.27694] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 01/23/2019] [Accepted: 01/23/2019] [Indexed: 12/14/2022]
Abstract
PURPOSE To develop a new high-dimensionality undersampled patch-based reconstruction (HD-PROST) for highly accelerated 2D and 3D multi-contrast MRI. METHODS HD-PROST jointly reconstructs multi-contrast MR images by exploiting the highly redundant information, on a local and non-local scale, and the strong correlation shared between the multiple contrast images. This is achieved by enforcing multi-dimensional low-rank in the undersampled images. 2D magnetic resonance fingerprinting (MRF) phantom and in vivo brain acquisitions were performed to evaluate the performance of HD-PROST for highly accelerated simultaneous T1 and T2 mapping. Additional in vivo experiments for reconstructing multiple undersampled 3D magnetization transfer (MT)-weighted images were conducted to illustrate the impact of HD-PROST for high-resolution multi-contrast 3D imaging. RESULTS In the 2D MRF phantom study, HD-PROST provided accurate and precise estimation of the T1 and T2 values in comparison to gold standard spin echo acquisitions. HD-PROST achieved good quality maps for the in vivo 2D MRF experiments in comparison to conventional low-rank inversion reconstruction. T1 and T2 values of white matter and gray matter were in good agreement with those reported in the literature for MRF acquisitions with reduced number of time point images (500 time point images, ~2.5 s scan time). For in vivo MT-weighted 3D acquisitions (6 different contrasts), HD-PROST achieved similar image quality than the fully sampled reference image for an undersampling factor of 6.5-fold. CONCLUSION HD-PROST enables multi-contrast 2D and 3D MR images in a short acquisition time without compromising image quality. Ultimately, this technique may increase the potential of conventional parameter mapping.
Collapse
Affiliation(s)
- Aurélien Bustin
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - Gastão Lima da Cruz
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - Olivier Jaubert
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - Karina Lopez
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
| | - René M. Botnar
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
- Escuela de IngenieríaPontificia Universidad Católica de ChileSantiagoChile
| | - Claudia Prieto
- Department of Biomedical Engineering, School of Imaging Sciences & Biomedical EngineeringKing’s College London, King’s Health PartnersLondonUnited Kingdom
- Escuela de IngenieríaPontificia Universidad Católica de ChileSantiagoChile
| |
Collapse
|
5
|
Krahn PRP, Singh SM, Ramanan V, Biswas L, Yak N, Anderson KJT, Barry J, Pop M, Wright GA. Cardiovascular magnetic resonance guided ablation and intra-procedural visualization of evolving radiofrequency lesions in the left ventricle. J Cardiovasc Magn Reson 2018; 20:20. [PMID: 29544514 PMCID: PMC5856306 DOI: 10.1186/s12968-018-0437-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 02/15/2018] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Radiofrequency (RF) ablation has become a mainstay of treatment for ventricular tachycardia, yet adequate lesion formation remains challenging. This study aims to comprehensively describe the composition and evolution of acute left ventricular (LV) lesions using native-contrast cardiovascular magnetic resonance (CMR) during CMR-guided ablation procedures. METHODS RF ablation was performed using an actively-tracked CMR-enabled catheter guided into the LV of 12 healthy swine to create 14 RF ablation lesions. T2 maps were acquired immediately post-ablation to visualize myocardial edema at the ablation sites and T1-weighted inversion recovery prepared balanced steady-state free precession (IR-SSFP) imaging was used to visualize the lesions. These sequences were repeated concurrently to assess the physiological response following ablation for up to approximately 3 h. Multi-contrast late enhancement (MCLE) imaging was performed to confirm the final pattern of ablation, which was then validated using gross pathology and histology. RESULTS Edema at the ablation site was detected in T2 maps acquired as early as 3 min post-ablation. Acute T2-derived edematous regions consistently encompassed the T1-derived lesions, and expanded significantly throughout the 3-h period post-ablation to 1.7 ± 0.2 times their baseline volumes (mean ± SE, estimated using a linear mixed model determined from n = 13 lesions). T1-derived lesions remained approximately stable in volume throughout the same time frame, decreasing to 0.9 ± 0.1 times the baseline volume (mean ± SE, estimated using a linear mixed model, n = 9 lesions). CONCLUSIONS Combining native T1- and T2-based imaging showed that distinctive regions of ablation injury are reflected by these contrast mechanisms, and these regions evolve separately throughout the time period of an intervention. An integrated description of the T1-derived lesion and T2-derived edema provides a detailed picture of acute lesion composition that would be most clinically useful during an ablation case.
Collapse
Affiliation(s)
- Philippa R. P. Krahn
- Department of Medical Biophysics, University of Toronto, Toronto, ON Canada
- Sunnybrook Research Institute, Toronto, ON Canada
| | - Sheldon M. Singh
- Schulich Heart Research Program, Sunnybrook Research Institute, Toronto, ON Canada
- Division of Cardiology, Schulich Heart Centre, Sunnybrook Health Sciences Centre, Toronto, ON Canada
- Faculty of Medicine, University of Toronto, Toronto, ON Canada
| | | | | | - Nicolas Yak
- Sunnybrook Research Institute, Toronto, ON Canada
| | | | | | - Mihaela Pop
- Department of Medical Biophysics, University of Toronto, Toronto, ON Canada
- Sunnybrook Research Institute, Toronto, ON Canada
- Schulich Heart Research Program, Sunnybrook Research Institute, Toronto, ON Canada
| | - Graham A. Wright
- Department of Medical Biophysics, University of Toronto, Toronto, ON Canada
- Sunnybrook Research Institute, Toronto, ON Canada
- Schulich Heart Research Program, Sunnybrook Research Institute, Toronto, ON Canada
| |
Collapse
|
6
|
Zhang L, Lai P, Pop M, Wright GA. Accelerated multicontrast volumetric imaging with isotropic resolution for improved peri-infarct characterization using parallel imaging, low-rank and spatially varying edge-preserving sparse modeling. Magn Reson Med 2017; 79:3018-3031. [PMID: 29030882 DOI: 10.1002/mrm.26970] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Revised: 09/21/2017] [Accepted: 09/22/2017] [Indexed: 01/27/2023]
Abstract
PURPOSE To achieve consistent effectiveness in reconstruction of fine image features for cases of varying contrast-to-noise ratio (CNR) to facilitate translating accelerated multicontrast volumetric imaging with isotropic resolution toward clinical utility in peri-infarct characterization. THEORY AND METHODS A low-rank and spatially varying edge-preserving constrained compressed sensing parallel imaging reconstruction method (CP-LASER) is developed to effectively preserve contrast of small-scale structures for highly accelerated multicontrast volumetric imaging in CNR-limited scenarios. CP-LASER synergistically integrates parallel imaging, low-rank and spatially varying edge-preserving sparse modeling to achieve high signal-to-noise-ratio efficiency by leveraging prior knowledge about signal properties including coil sensitivity weighting, spatiotemporally correlated signal relaxation, and spatially varying sparsity. RESULTS In the preclinical study using highly accelerated multicontrast volumetric imaging with an isotropic 1.5-mm resolution, CP-LASER demonstrated robust multicontrast reconstruction of peri-infarct characteristics with excellent correspondence with histopathology. CP-LASER provides better delineation of the peri-infarct border zone with improved sharpness than alternative methods in a clinical demonstration on 1.5T with an isotropic 2.2-mm resolution achieved in a single breath-hold. CONCLUSION Accelerated multicontrast volumetric imaging with isotropic resolution using CP-LASER has demonstrated the potential to improve peri-infarct characterization in a clinical setting. Magn Reson Med 79:3018-3031, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Li Zhang
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Schulich Heart Research Program and Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Peng Lai
- Global Applied Science Laboratory, GE Healthcare, Menlo Park, California, USA
| | - Mihaela Pop
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Schulich Heart Research Program and Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Graham A Wright
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Schulich Heart Research Program and Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| |
Collapse
|
7
|
Wu KC. Sudden Cardiac Death Substrate Imaged by Magnetic Resonance Imaging: From Investigational Tool to Clinical Applications. Circ Cardiovasc Imaging 2017. [PMID: 28637807 DOI: 10.1161/circimaging.116.005461] [Citation(s) in RCA: 56] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Sudden cardiac death (SCD) is a devastating event afflicting 350 000 Americans annually despite the availability of life-saving preventive therapy, the implantable cardioverter defibrillator. SCD prevention strategies are hampered by over-reliance on global left ventricular ejection fraction <35% as the most important criterion to determine implantable cardioverter defibrillator candidacy. Annually in the United States alone, this results in ≈130 000 implantable cardioverter defibrillator placements at a cost of >$3 billion but only a 5% incidence per year of appropriate firings. This approach further fails to identify individuals who experience the majority, as many as 80%, of SCD events, which occur in the setting of more preserved left ventricular ejection fraction. Better risk stratification is needed to improve care and should be guided by direct pathophysiologic markers of arrhythmic substrate, such as specific left ventricular structural abnormalities. There is an increasing body of literature to support the prognostic value of cardiac magnetic resonance imaging with late gadolinium enhancement in phenotyping the left ventricular to identify those at highest risk for SCD. Cardiac magnetic resonance has unparalleled tissue characterization ability and provides exquisite detail about myocardial structure and composition, abnormalities of which form the direct, pathophysiologic substrate for SCD. Here, we review the evolution and the current state of cardiac magnetic resonance for imaging the arrhythmic substrate, both as a research tool and for clinical applications.
Collapse
Affiliation(s)
- Katherine C Wu
- From the Division of Cardiology, Johns Hopkins Medical Institutions, Baltimore, MD.
| |
Collapse
|