• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4620793)   Today's Articles (7810)   Subscriber (49405)
For: Bhusal B, Bhattacharyya P, Baig T, Jones S, Martens M. Measurements and simulation of RF heating of implanted stereo-electroencephalography electrodes during MR scans. Magn Reson Med 2018;80:1676-1685. [DOI: 10.1002/mrm.27144] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 01/26/2018] [Accepted: 01/31/2018] [Indexed: 12/18/2022]
Number Cited by Other Article(s)
1
Eijbersen MA, Steensma BR, van den Berg CAT, Raaijmakers AJE. An improved method to measure transfer functions using MRI. Magn Reson Med 2024;92:2246-2260. [PMID: 38860561 DOI: 10.1002/mrm.30179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 05/07/2024] [Accepted: 05/12/2024] [Indexed: 06/12/2024]
2
Jiang F, Henry KR, Bhusal B, Sanpitak P, Webster G, Popescu A, Laternser C, Kim D, Golestanirad L. Age Matters: A Comparative Study of RF Heating of Epicardial and Endocardial Electronic Devices in Pediatric and Adult Phantoms during Cardiothoracic MRI. Diagnostics (Basel) 2023;13:2847. [PMID: 37685385 PMCID: PMC10486594 DOI: 10.3390/diagnostics13172847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 06/29/2023] [Accepted: 08/04/2023] [Indexed: 09/10/2023]  Open
3
Vu J, Bhusal B, Nguyen BT, Sanpitak P, Nowac E, Pilitsis J, Rosenow J, Golestanirad L. A comparative study of RF heating of deep brain stimulation devices in vertical vs. horizontal MRI systems. PLoS One 2022;17:e0278187. [PMID: 36490249 PMCID: PMC9733854 DOI: 10.1371/journal.pone.0278187] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 11/11/2022] [Indexed: 12/13/2022]  Open
4
Fujita Y, Khoo HM, Hirayama M, Kawahara M, Koyama Y, Tarewaki H, Arisawa A, Yanagisawa T, Tani N, Oshino S, Lemieux L, Kishima H. Evaluating the Safety of Simultaneous Intracranial Electroencephalography and Functional Magnetic Resonance Imaging Acquisition Using a 3 Tesla Magnetic Resonance Imaging Scanner. Front Neurosci 2022;16:921922. [PMID: 35812224 PMCID: PMC9259878 DOI: 10.3389/fnins.2022.921922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 05/25/2022] [Indexed: 11/13/2022]  Open
5
A perturbation approach for ultrafast calculation of RF field enhancements near medical implants in MRI. Sci Rep 2022;12:4224. [PMID: 35273313 PMCID: PMC8913743 DOI: 10.1038/s41598-022-08004-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 02/22/2022] [Indexed: 11/08/2022]  Open
6
Bhusal B, Bhattacharyya P, Baig T, Jones S, Martens M. Effect of inter-electrode RF coupling on heating patterns of wire-like conducting implants in MRI. Magn Reson Med 2022;87:2933-2946. [PMID: 35092097 DOI: 10.1002/mrm.29177] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 12/16/2021] [Accepted: 01/09/2022] [Indexed: 11/05/2022]
7
Nguyen BT, Bhusal B, Rahsepar AA, Fawcett K, Lin S, Marks DS, Passman R, Nieto D, Niemzcura R, Golestanirad L. Safety of MRI in patients with retained cardiac leads. Magn Reson Med 2021;87:2464-2480. [PMID: 34958685 PMCID: PMC8919805 DOI: 10.1002/mrm.29116] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 11/18/2021] [Accepted: 11/20/2021] [Indexed: 11/17/2022]
8
Stijnman PRS, Erturk MA, van den Berg CAT, Raaijmakers AJE. A single setup approach for the MRI-based measurement and validation of the transfer function of elongated medical implants. Magn Reson Med 2021;86:2751-2765. [PMID: 34036617 PMCID: PMC8596675 DOI: 10.1002/mrm.28840] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 04/23/2021] [Accepted: 04/23/2021] [Indexed: 12/15/2022]
9
Bhusal B, Stockmann J, Guerin B, Mareyam A, Kirsch J, Wald LL, Nolt MJ, Rosenow J, Lopez-Rosado R, Elahi B, Golestanirad L. Safety and image quality at 7T MRI for deep brain stimulation systems: Ex vivo study with lead-only and full-systems. PLoS One 2021;16:e0257077. [PMID: 34492090 PMCID: PMC8423254 DOI: 10.1371/journal.pone.0257077] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 08/23/2021] [Indexed: 11/19/2022]  Open
10
Nguyen BT, Pilitsis J, Golestanirad L. The effect of simulation strategies on prediction of power deposition in the tissue around electronic implants during magnetic resonance imaging. ACTA ACUST UNITED AC 2020;65:185007. [DOI: 10.1088/1361-6560/abac9f] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
11
Bhusal B, Nguyen BT, Sanpitak PP, Vu J, Elahi B, Rosenow J, Nolt MJ, Lopez‐Rosado R, Pilitsis J, DiMarzio M, Golestanirad L. Effect of Device Configuration and Patient's Body Composition on the RF Heating and Nonsusceptibility Artifact of Deep Brain Stimulation Implants During MRI at 1.5T and 3T. J Magn Reson Imaging 2020;53:599-610. [DOI: 10.1002/jmri.27346] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 08/12/2020] [Accepted: 08/13/2020] [Indexed: 12/13/2022]  Open
12
Bhusal B, Nguyen BT, Vu J, Elahi B, Rosenow J, Nolt MJ, Pilitsis J, DiMarzio M, Golestanirad L. Device Configuration and Patient's Body Composition Significantly Affect RF Heating of Deep Brain Stimulation Implants During MRI: An Experimental Study at 1.5T and 3T. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020;2020:5192-5197. [PMID: 33019155 PMCID: PMC10900233 DOI: 10.1109/embc44109.2020.9175833] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
13
Modeling radiofrequency responses of realistic multi-electrode leads containing helical and straight wires. MAGMA (NEW YORK, N.Y.) 2020;33:421-437. [PMID: 31745756 PMCID: PMC7230065 DOI: 10.1007/s10334-019-00793-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 09/27/2019] [Accepted: 10/24/2019] [Indexed: 11/04/2022]
14
Needle Heating During Interventional Magnetic Resonance Imaging at 1.5- and 3.0-T Field Strengths. Invest Radiol 2020;55:396-404. [DOI: 10.1097/rli.0000000000000649] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
15
Özen AC, Silemek B, Lottner T, Atalar E, Bock M. MR safety watchdog for active catheters: Wireless impedance control with real-time feedback. Magn Reson Med 2020;84:1048-1060. [PMID: 31961965 DOI: 10.1002/mrm.28153] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 11/29/2019] [Accepted: 12/09/2019] [Indexed: 12/13/2022]
16
Wang Y, Wang Q, Liu J, Zeng Q, Zheng J, Kainz W, Chen J. On the development of equivalent medium for active implantable device radiofrequency safety assessment. Magn Reson Med 2019;82:1164-1176. [DOI: 10.1002/mrm.27785] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 03/06/2019] [Accepted: 04/04/2019] [Indexed: 12/31/2022]
17
Risk assessment of copper-containing contraceptives: the impact for women with implanted intrauterine devices during clinical MRI and CT examinations. Eur Radiol 2018;29:2812-2820. [PMID: 30456586 DOI: 10.1007/s00330-018-5864-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Revised: 09/28/2018] [Accepted: 10/25/2018] [Indexed: 12/19/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA