Duan S, Wu X, Shi J, Li W, Dong Q, Xin SX. Study of the radiofrequency-induced heating inside the human head with dental implants at 7 T. Bioelectromagnetics 2024; 45:82-93. [PMID: 37860924 DOI: 10.1002/bem.22490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 08/28/2023] [Accepted: 10/09/2023] [Indexed: 10/21/2023]
Abstract
Conductive dental implants are commonly used in restorative therapy to replace missing teeth in patients. Ensuring the radiofrequency (RF) safety of these patients is crucial when performing 7 T magnetic resonance scans of their heads. This study aimed to investigate RF-induced heating inside the human head with dental implants at 7 T. Dental implants and their attachments were fabricated and integrated into an anatomical head model, creating different measurement configurations (MCs). Numerical simulations were conducted using a 7 T transmit coil loaded with the anatomical head model, both with and without dental implants. The maximum temperatures inside the head for various MCs were computed using the maximum permissible input powers (MPIPs) obtained without dental implants and compared with published limits. Additionally, the MPIPs with dental implants were calculated for scenarios where the temperature limits were exceeded. The maximum temperatures observed inside the head ranged from 38.4°C to 39.6°C. The MPIPs in the presence of dental implants were 81.9%-97.3% of the MPIPs in the absence of dental implants for scenarios that exceeded the regulatory limit. RF-induced heating effect of the dental implants was not significant. The safe scanning condition in terms of RF exposure was achievable for patients with dental implants. For patients with conductive dental implants of unknown configuration, it is recommended to reduce the input power by 18.1% of MPIP without dental implants to ensure RF safety.
Collapse
Affiliation(s)
- Song Duan
- Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Xiuxiu Wu
- Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Juntian Shi
- Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Wenhui Li
- Department of Dentistry, Air Force Hospital of Southern Theater Command of PLA, Guangzhou, Guangdong, China
| | - Qingshan Dong
- Department of Stomatology, General Hospital of Central Theater Command of PLA, WuHan, China
| | - Sherman Xuegang Xin
- Biophysics and Medical Imaging Lab, School of Medicine, South China University of Technology, Guangzhou, Guangdong, China
| |
Collapse
|
2
|
Petzold J, Schmitter S, Silemek B, Winter L, Speck O, Ittermann B, Seifert F. Towards an integrated radiofrequency safety concept for implant carriers in MRI based on sensor-equipped implants and parallel transmission. NMR IN BIOMEDICINE 2023; 36:e4900. [PMID: 36624556 DOI: 10.1002/nbm.4900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 10/11/2022] [Accepted: 01/04/2023] [Indexed: 06/15/2023]
Abstract
To protect implant carriers in MRI from excessive radiofrequency (RF) heating it has previously been suggested to assess that hazard via sensors on the implant. Other work recommended parallel transmission (pTx) to actively mitigate implant-related heating. Here, both ideas are integrated into one comprehensive safety concept where native pTx safety (without implant) is ensured by state-of-the-art field simulations and the implant-specific hazard is quantified in situ using physical sensors. The concept is demonstrated by electromagnetic simulations performed on a human voxel model with a simplified spinal-cord implant in an eight-channel pTx body coil at 3 T . To integrate implant and native safety, the sensor signal must be calibrated in terms of an established safety metric (e.g., specific absorption rate [SAR]). Virtual experiments show that E -field and implant-current sensors are well suited for this purpose, while temperature sensors require some caution, and B 1 probes are inadequate. Based on an implant sensor matrix Q s , constructed in situ from sensor readings, and precomputed native SAR limits, a vector space of safe RF excitations is determined where both global (native) and local (implant-related) safety requirements are satisfied. Within this safe-excitation subspace, the solution with the best image quality in terms of B 1 + magnitude and homogeneity is then found by a straightforward optimization algorithm. In the investigated example, the optimized pTx shim provides a 3-fold higher mean B 1 + magnitude compared with circularly polarized excitation for a maximum implant-related temperature increase ∆ T imp ≤ 1 K . To date, sensor-equipped implants interfaced to a pTx scanner exist as demonstrator items in research labs, but commercial devices are not yet within sight. This paper aims to demonstrate the significant benefits of such an approach and how this could impact implant-related RF safety in MRI. Today, the responsibility for safe implant scanning lies with the implant manufacturer and the MRI operator; within the sensor concept, the MRI manufacturer would assume much of the operator's current responsibility.
Collapse
Affiliation(s)
- Johannes Petzold
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
- Biomedical Magnetic Resonance, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Berk Silemek
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Lukas Winter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Oliver Speck
- Biomedical Magnetic Resonance, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Bernd Ittermann
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Frank Seifert
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| |
Collapse
|
3
|
Arduino A, Bottauscio O, Chiampi M, Zanovello U, Zilberti L. A contribution to MRI safety testing related to gradient-induced heating of medical devices. Magn Reson Med 2022; 88:930-944. [PMID: 35344605 PMCID: PMC9314691 DOI: 10.1002/mrm.29235] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 01/22/2022] [Accepted: 02/24/2022] [Indexed: 12/26/2022]
Abstract
PURPOSE To theoretically investigate the feasibility of a novel procedure for testing the MRI gradient-induced heating of medical devices and translating the results into clinical practice. METHODS The concept of index of stress is introduced by decoupling the time waveform characteristics of the gradient field signals from the field spatial distribution within an MRI scanner. This index is also extended to consider the anisotropy of complex bulky metallic implants. Merits and drawbacks of the proposed index of stress are investigated through virtual experiments. In particular, the values of the index of stress evaluated for realistic orthopedic implants placed within an ASTM phantom are compared with accurate heating simulations performed with 2 anatomic body models (a man and a woman) implanted through a virtual surgery procedure. RESULTS The manipulation of the proposed index of stress allows to identify regions within the MRI bore where the implant could affect the safety of the examinations. Furthermore, the conducted analysis shows that the power dissipated into the implant by the induced eddy currents is a dosimetric quantity that estimates well the maximum temperature increase in the tissues surrounding the implant. CONCLUSION The results support the adoption of an anisotropic index of stress to regulate the gradient-induced heating of geometrically complex implants. They also pave the way for a laboratory characterization of the implants based on electrical measurements, rather than on thermal measurements. The next step will be to set up a standardized experimental procedure to evaluate the index of stress associated with an implant.
Collapse
Affiliation(s)
| | | | - Mario Chiampi
- Istituto Nazionale di Ricerca Metrologica (INRIM), Torino, Italy
| | | | - Luca Zilberti
- Istituto Nazionale di Ricerca Metrologica (INRIM), Torino, Italy
| |
Collapse
|
4
|
Seo JH, Chung JY. A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T. SENSORS 2022; 22:s22041512. [PMID: 35214409 PMCID: PMC8875900 DOI: 10.3390/s22041512] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 02/13/2022] [Accepted: 02/14/2022] [Indexed: 02/05/2023]
Abstract
Magnetic resonance imaging (MRI) systems must undergo quantitative evaluation through daily and periodic performance assessments. In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B1-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (UHF) MRI systems above 3.0 T. Herein, we propose a hybrid-type BC (Hybrid-BC) RF coil as a reference RF coil with improved B1-field sensitivity in UHF MRI system and applied it to an 11.7 T MRI system. An electromagnetic field (EM-field) analysis on the Hybrid-BC RF coil was performed to provide the proper dimensions for its use as a reference RF coil. Commercial finite difference time-domain program was used in EM-field simulation, and home-made analysis programs were used in analysis. The optimal specifications of the proposed Hybrid-BC RF coils for them to qualify as reference RF coils are proposed based on their B1+-field sensitivity under unnormalized conditions, as well as by considering their B1+-field uniformity and RF safety under normalized conditions.
Collapse
Affiliation(s)
- Jeung-Hoon Seo
- Neuroscience Research Institute, Gachon University, Incheon 21988, Korea;
| | - Jun-Young Chung
- Department of Neuroscience, College of Medicine, Gachon University, Incheon 21565, Korea
- Correspondence: ; Tel.: +82-32-822-5361; Fax: +82-32-822-8251
| |
Collapse
|
5
|
Steensma BR, Meliadò EF, Luijten P, Klomp DWJ, van den Berg CAT, Raaijmakers AJE. SAR and temperature distributions in a database of realistic human models for 7 T cardiac imaging. NMR IN BIOMEDICINE 2021; 34:e4525. [PMID: 33955061 PMCID: PMC8244032 DOI: 10.1002/nbm.4525] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 03/23/2021] [Accepted: 03/27/2021] [Indexed: 06/12/2023]
Abstract
PURPOSE To investigate inter-subject variability of B1+ , SAR and temperature rise in a database of human models using a local transmit array for 7 T cardiac imaging. METHODS Dixon images were acquired of 14 subjects and segmented in dielectric models with an eight-channel local transmit array positioned around the torso for cardiac imaging. EM simulations were done to calculate SAR distributions. Based on the SAR distributions, temperature simulations were performed for exposure times of 6 min and 30 min. Peak local SAR and temperature rise levels were calculated for different RF shim settings. A statistical analysis of the resulting peak local SAR and temperature rise levels was performed to arrive at safe power limits. RESULTS For RF shim vectors with random phase and uniformly distributed power, a safe average power limit of 35.7 W was determined (first level controlled mode). When RF amplitude and phase shimming was performed on the heart, a safe average power limit of 35.0 W was found. According to Pennes' model, our numerical study suggests a very low probability of exceeding the absolute local temperature limit of 40 °C for a total exposure time of 6 min and a peak local SAR of 20 W/kg. For a 30 min exposure time at 20 W/kg, it was shown that the absolute temperature limit can be exceeded in the case where perfusion does not change with temperature. CONCLUSION Safe power constraints were found for 7 T cardiac imaging with an eight-channel local transmit array, while considering the inter-subject variability of B1+ , SAR and temperature rise.
Collapse
Affiliation(s)
- Bart R. Steensma
- Center for Image SciencesUniversity Medical Center UtrechtUtrechtThe Netherlands
| | - Ettore F. Meliadò
- Center for Image SciencesUniversity Medical Center UtrechtUtrechtThe Netherlands
- Tesla Dynamic CoilsZaltbommelThe Netherlands
| | - Peter Luijten
- Center for Image SciencesUniversity Medical Center UtrechtUtrechtThe Netherlands
| | - Dennis W. J. Klomp
- Center for Image SciencesUniversity Medical Center UtrechtUtrechtThe Netherlands
| | | | | |
Collapse
|
6
|
Arduino A, Zanovello U, Hand J, Zilberti L, Brühl R, Chiampi M, Bottauscio O. Heating of hip joint implants in MRI: The combined effect of RF and switched-gradient fields. Magn Reson Med 2021; 85:3447-3462. [PMID: 33483979 PMCID: PMC7986841 DOI: 10.1002/mrm.28666] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 12/09/2020] [Accepted: 12/09/2020] [Indexed: 12/20/2022]
Abstract
PURPOSE To investigate how the simultaneous exposure to gradient and RF fields affects the temperature rise in patients with a metallic hip prosthesis during an MRI session. METHODS In silico analysis was performed with an anatomically realistic human model with CoCrMo hip implant in 12 imaging positions. The analysis was performed at 1.5 T and 3 T, considering four clinical sequences: turbo spin-echo, EPI, gradient-echo, and true fast imaging sequence with steady precession. The exposure to gradient and RF fields was evaluated separately and superposed, by adopting an ad hoc computational algorithm. Temperature increase within the body, rather than specific absorption rate, was used as a safety metric. RESULTS With the exception of gradient-echo, all investigated sequences produced temperature increases higher than 1 K after 360 seconds, at least for one body position. In general, RF-induced heating dominates the turbo spin-echo sequence, whereas gradient-induced heating prevails with EPI; the situation with fast imaging sequence with steady precession is more diversified. The RF effects are enhanced when the implant is within the RF coil, whereas the effects of gradient fields are maximized if the prosthesis is outside the imaging region. Cases for which temperature-increase thresholds were exceeded were identified, together with the corresponding amount of tissue mass involved and the exposure time needed to reach these limits. CONCLUSION The analysis confirms that risky situations may occur when a patient carrying a hip implant undergoes an MRI exam and that, in some cases, the gradient field heating may be significant. In general, exclusion criteria only based on whole-body specific absorption rate may not be sufficient to ensure patients' safety.
Collapse
Affiliation(s)
| | | | - Jeff Hand
- School of Biomedical Engineering and Imaging SciencesKing’s College LondonLondonUnited Kingdom
| | - Luca Zilberti
- Istituto Nazionale di Ricerca Metrologica (INRIM)TorinoItaly
| | - Rüdiger Brühl
- Physikalisch‐Technische BundesanstaltBraunschweig and BerlinGermany
| | - Mario Chiampi
- Istituto Nazionale di Ricerca Metrologica (INRIM)TorinoItaly
| | | |
Collapse
|
7
|
Fagan AJ, Bitz AK, Björkman-Burtscher IM, Collins CM, Kimbrell V, Raaijmakers AJ. 7T MR Safety. J Magn Reson Imaging 2021; 53:333-346. [PMID: 32830900 PMCID: PMC8170917 DOI: 10.1002/jmri.27319] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 07/21/2020] [Accepted: 07/22/2020] [Indexed: 12/11/2022] Open
Abstract
Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh-field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer-published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2 J. MAGN. RESON. IMAGING 2021;53:333-346.
Collapse
Affiliation(s)
- Andrew J. Fagan
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Andreas K. Bitz
- Faculty of Electrical Engineering and Information Technology, FH Aachen - University of Applied Sciences, Aachen, Germany
| | - Isabella M. Björkman-Burtscher
- Department of Radiology, University of Gothenburg, Sahlgrenska Academy, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Christopher M. Collins
- Center for Advanced Imaging Innovation and Research, NYU Langone Medical Center, New York, New York, USA
| | - Vera Kimbrell
- Department of Radiology, Brigham and Women’s Hospital, Boston, Massachusetts, USA
| | | | | |
Collapse
|
8
|
Exposure levels of radiofrequency magnetic fields and static magnetic fields in 1.5 and 3.0 T MRI units. SN APPLIED SCIENCES 2021. [DOI: 10.1007/s42452-021-04178-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
AbstractMagnetic resonance imaging (MRI) staff is exposed to a complex mixture of electromagnetic fields from MRI units. Exposure to these fields results in the development of transient exposure-related symptoms. This study aimed to investigate the exposure levels of radiofrequency (RF) magnetic fields and static magnetic fields (SMFs) from 1.5 and 3.0 T MRI scanners in two public hospitals in the Mangaung Metropolitan region, South Africa. The exposure levels of SMFs and RF magnetic fields were measured using the THM1176 3-Axis hall magnetometer and TM-196 3 Axis RF field strength meter, respectively. Measurements were collected at a distance of 1 m (m) and 2 m from the gantry for SMFs when the brain, cervical spine and extremities were scanned. Measurements for RF magnetic fields were collected at a distance of 1 m with an average scan duration of six minutes. Friedman’s test was used to compared exposure mean values from two 1.5 T scanners, and Wilcoxon test with Bonferroni adjustment was used to identify where the difference between exist. The Shapiro–Wilk test was also used to test for normality between exposure levels in 1.5 and 3.0 T scanners. The measured peak values for SMFs from the 3.0 T scanner at hospital A were 1300 milliTesla (mT) and 726 mT from 1.5 T scanner in hospital B. The difference in terms of SMFs exposure levels was observed between two 1.5 T scanners at a distance of 2 m. The difference between 1.5 T scanners at 1 m was also observed during repeated measurements when brain, cervical spine and extremities scans were performed. Scanners’ configurations, magnet type, clinical setting and location were identified as factors that could influence different propagation of SMFs between scanners of the same nominal B0. The RF pulse design, sequence setting flip-angle and scans performed influenced the measured RF magnetic fields. Three scanners were complaint with occupational exposure guidelines stipulated by the ICNIRP; however, peak levels that exist at 1 m could be managed through adoption of occupational health and safety programs.
Collapse
|
9
|
Zilberti L, Zanovello U, Arduino A, Bottauscio O, Chiampi M. RF-induced heating of metallic implants simulated as PEC: Is there something missing? Magn Reson Med 2020; 85:583-586. [PMID: 32936504 DOI: 10.1002/mrm.28512] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 08/17/2020] [Accepted: 08/18/2020] [Indexed: 01/06/2023]
Affiliation(s)
- Luca Zilberti
- Istituto Nazionale di Ricerca Metrologica, Torino, Italy
| | | | | | | | - Mario Chiampi
- Istituto Nazionale di Ricerca Metrologica, Torino, Italy
| |
Collapse
|
10
|
Winter L, Seifert F, Zilberti L, Murbach M, Ittermann B. MRI‐Related Heating of Implants and Devices: A Review. J Magn Reson Imaging 2020; 53:1646-1665. [DOI: 10.1002/jmri.27194] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 04/29/2020] [Accepted: 04/30/2020] [Indexed: 12/11/2022] Open
Affiliation(s)
- Lukas Winter
- Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
| | - Frank Seifert
- Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
| | - Luca Zilberti
- Istituto Nazionale di Ricerca Metrologica Torino Italy
| | - Manuel Murbach
- ZMT Zurich MedTech AG Zurich Switzerland
- Institute for Molecular Instrumentation and Imaging (i3M) Universidad Politécnica de Valencia (UPV) Valencia Spain
| | - Bernd Ittermann
- Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany
| |
Collapse
|
11
|
Arduino A, Bottauscio O, Brühl R, Chiampi M, Zilberti L. In silico evaluation of the thermal stress induced by MRI switched gradient fields in patients with metallic hip implant. ACTA ACUST UNITED AC 2019; 64:245006. [DOI: 10.1088/1361-6560/ab5428] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
12
|
Noureddine Y, Kraff O, Ladd ME, Wrede K, Chen B, Quick HH, Schaefers G, Bitz AK. Radiofrequency induced heating around aneurysm clips using a generic birdcage head coil at 7 Tesla under consideration of the minimum distance to decouple multiple aneurysm clips. Magn Reson Med 2019; 82:1859-1875. [DOI: 10.1002/mrm.27835] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 05/08/2019] [Accepted: 05/10/2019] [Indexed: 12/13/2022]
Affiliation(s)
- Yacine Noureddine
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg‐Essen Essen Germany
- MR:comp GmbH, MR Safety Testing Laboratory Gelsenkirchen Germany
| | - Oliver Kraff
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg‐Essen Essen Germany
| | - Mark E. Ladd
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg‐Essen Essen Germany
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ) Heidelberg Germany
- Faculty of Physics and Astronomy and Faculty of Medicine University of Heidelberg Heidelberg Germany
| | - Karsten Wrede
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg‐Essen Essen Germany
- Department of Neurosurgery University Hospital Essen Essen Germany
| | - Bixia Chen
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg‐Essen Essen Germany
- Department of Neurosurgery University Hospital Essen Essen Germany
| | - Harald H. Quick
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg‐Essen Essen Germany
- High Field and Hybrid MR, University Hospital Essen Essen Germany
| | - Gregor Schaefers
- MR:comp GmbH, MR Safety Testing Laboratory Gelsenkirchen Germany
- MRI‐STaR – Magnetic Resonance Institute for Safety, Technology and Research GmbH Gelsenkirchen Germany
| | - Andreas K. Bitz
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ) Heidelberg Germany
- Faculty of Electrical Engineering and Information Technology FH Aachen University of Applied Sciences Aachen NRW Germany
| |
Collapse
|
13
|
Destruel A, Fuentes M, Weber E, O'Brien K, Jin J, Liu F, Barth M, Crozier S. A numerical and experimental study of RF shimming in the presence of hip prostheses using adaptive SAR at 3 T. Magn Reson Med 2019; 81:3826-3839. [PMID: 30803001 DOI: 10.1002/mrm.27688] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 01/17/2019] [Accepted: 01/20/2019] [Indexed: 12/25/2022]
Abstract
PURPOSE Parallel transmission techniques in MRI have the potential to improve the image quality near metal implants at 3 T. However, current testing of implants only evaluates the risk of radiofrequency (RF) heating in phantoms in circularly polarized mode. We investigate the influence of changing the transmission settings in a 2-channel body coil on the peak temperature near 2 CoCrMo hip prostheses, using adaptive specific absorption rate (SAR) as an estimate of RF heating. METHODS Adaptive SAR is a SAR averaging method that is optimized to correlate with thermal simulations and limit the temperature to 39°C near hip implants. The simulated peak temperature was compared when using whole-body SAR, SAR10g , and adaptive SAR as a constraint for the maximum allowed input power. Adaptive SAR was used as a fast estimate of temperature to evaluate the trade-off between good image quality and low heating near the hip implants. Electromagnetic simulations were validated by simulating and measuring B1 maps and electric fields in a phantom at 3 T. RESULTS Simulations and measurements showed excellent agreement. Limiting whole-body SAR to 2 W/kg and SAR10g to 10 W/kg resulted in temperatures up to 49.3°C and 40.7°C near the hip implants after 30 minutes of RF exposure, respectively. Predictions based on adaptive SAR limited the temperature to 39°C, and allowed to improve the B1 field distribution while preventing peak temperatures near the hip implants. CONCLUSION Significant RF heating can occur at 3 T near hip implants when parallel transmission is used. Adaptive SAR can be integrated in RF shimming algorithms to improve the uniformity and reduce heating.
Collapse
Affiliation(s)
- Aurelien Destruel
- School of Information Technology and Electrical Engineering, University of Queensland, St. Lucia, Australia.,Centre for Advanced Imaging, University of Queensland, St. Lucia, Australia
| | - Miguel Fuentes
- School of Information Technology and Electrical Engineering, University of Queensland, St. Lucia, Australia.,Population Health Research on Electromagnetic Energy, School of Public Health and Preventive Medicine, Monash University, Clayton, Australia
| | - Ewald Weber
- School of Information Technology and Electrical Engineering, University of Queensland, St. Lucia, Australia
| | - Kieran O'Brien
- Centre for Advanced Imaging, University of Queensland, St. Lucia, Australia.,Siemens Healthcare, Brisbane, Australia
| | - Jin Jin
- Siemens Healthineers USA, Los Angeles, California
| | - Feng Liu
- School of Information Technology and Electrical Engineering, University of Queensland, St. Lucia, Australia
| | - Markus Barth
- Centre for Advanced Imaging, University of Queensland, St. Lucia, Australia
| | - Stuart Crozier
- School of Information Technology and Electrical Engineering, University of Queensland, St. Lucia, Australia
| |
Collapse
|
14
|
Destruel A, O'Brien K, Jin J, Liu F, Barth M, Crozier S. Adaptive SAR mass-averaging framework to improve predictions of local RF heating near a hip implant for parallel transmit at 7 T. Magn Reson Med 2018; 81:615-627. [PMID: 30058186 DOI: 10.1002/mrm.27379] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 04/26/2018] [Accepted: 05/07/2018] [Indexed: 12/26/2022]
Abstract
PURPOSE Magnetic resonance imaging is used increasingly to scan patients with hip prostheses. We evaluated the reliability of 10 g-averaged specific absorption rate (SAR10g ) to predict radiofrequency (RF) heating in tissues surrounding a hip implant at 7 T in an 8-channel pTx hip coil. A new adaptive SAR mass-averaging method is proposed to improve the correlation between the distribution of mass-averaged SAR and that of tissue temperature. METHODS Currently, RF safety standards for implants are based on temperature instead of SAR, as SAR has not been introduced with regard to exposure scenarios with implants. In this manuscript, however, adaptive SAR is proposed for fast and reliable exposure evaluation with implants, after its correlation with tissue temperature is verified. A framework to calculate adaptive SAR mass-averaging was introduced, which uses a different averaging mass in tissues surrounding the implants and was designed to prevent the temperature from exceeding 39ºC. Predictions from SAR10g and adaptive SAR were compared with thermal simulations. RESULTS The SAR10g method failed to predict both the location and amplitude of heating in tissue near the metal implants. In some cases, the temperature far exceeded 39ºC even when SAR10g was only 70% of the maximum allowed 10 W/kg. The distributions of adaptive SAR and temperature matched in most of the configurations, and the temperature remained below 39ºC when adaptive SAR was constrained. CONCLUSION Adaptive SAR can accurately monitor RF heating and could be used for parallel transmit at 7 T to supplement current standards.
Collapse
Affiliation(s)
- Aurelien Destruel
- School of Information Technology and Electrical Engineering, University of Queensland, Australia.,Centre for Advanced Imaging, University of Queensland, Australia
| | - Kieran O'Brien
- Centre for Advanced Imaging, University of Queensland, Australia.,Siemens Healthcare Pty Ltd, Brisbane, Australia
| | - Jin Jin
- School of Information Technology and Electrical Engineering, University of Queensland, Australia.,Siemens Medical Solutions USA, Malvern, Pennsylvania.,Institute for Neuroimaging and Informatics, University of Southern California, Los Angeles, California
| | - Feng Liu
- School of Information Technology and Electrical Engineering, University of Queensland, Australia
| | - Markus Barth
- Centre for Advanced Imaging, University of Queensland, Australia
| | - Stuart Crozier
- School of Information Technology and Electrical Engineering, University of Queensland, Australia
| |
Collapse
|