1
|
Sakurama A, Fushimi Y, Nakajima S, Sakata A, Okuchi S, Yamamoto T, Otani S, Wicaksono KP, Ikeda S, Ito S, Maki T, Liu W, Nakamoto Y. Comparison study of quantitative susceptibility mapping with GRAPPA and wave-CAIPI: reproducibility, consistency, and microbleeds detection. Jpn J Radiol 2024:10.1007/s11604-024-01683-4. [PMID: 39467931 DOI: 10.1007/s11604-024-01683-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2024] [Accepted: 10/12/2024] [Indexed: 10/30/2024]
Abstract
PURPOSE We compared quantitative susceptibility mapping (QSM) with wave-CAIPI 9 × (QSM_WC9 ×) with reference standard QSM with GRAPPA 2 × (QSM_G2 ×) in two MR scanners. We also compared detectability of microbleeds in both QSMs to demonstrate clinical feasibility of both QSMs. MATERIALS AND METHODS This prospective study was approved by the institutional review board and written informed consent was obtained from each subject. Healthy subjects were recruited to evaluate intra-scanner reproducibility, inter-scanner consistency, and inter-sequence consistency of QSM_G2 × and QSM_WC9 × at 2 MR scanners. Susceptibility values measured with volume of interests (VOIs) were evaluated. Patients who were requested for susceptibility weighted imaging were also recruited in this study to measure microbleeds on QSM_G2 × and QSM_WC9 × . The number of microbleeds was compared between two QSMs. RESULTS Total 55 healthy subjects (male 34, female 21, 38.3 years [23-79]) were included in this study. We investigated reproducibility and consistency of QSM_WC9 × by comparing reference standard QSM_G2 × in two MR scanners in this study, and high correlation (ρ, 0.93-0.97) and high intraclass correlation coefficient (ICC) (0.97-0.99) were obtained. Sixty patients (male 30, female 30; age, 55.4 years [21-85]) were finally enrolled in this prospective study. The ICC of the detected number of microbleeds between QSM_G2 × and QSM_WC9 × was 0.99 (0.98-0.99). CONCLUSION QSM_WC9 × and reference standard QSM_G2 × in two MR scanners showed good reproducibility and consistency in estimating magnetic susceptibilities. QSM_WC9 × and QSM_G2 × were also comparable in terms of microbleeds detection with good agreement of raters and high ICC.
Collapse
Affiliation(s)
- Azusa Sakurama
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Yasutaka Fushimi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan.
| | - Satoshi Nakajima
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Akihiko Sakata
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Sachi Okuchi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Takayuki Yamamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Sayo Otani
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Krishna Pandu Wicaksono
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
- Department of Radiology, Faculty of Medicine, Universitas Indonesia-Dr. Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia
| | - Satoshi Ikeda
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Shuichi Ito
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| | - Takakuni Maki
- Department of Neurology, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Wei Liu
- Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen, China
| | - Yuji Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-Cho, Sakyo-Ku, Kyoto, 606-8507, Japan
| |
Collapse
|
2
|
Shen X, Özen AC, Sunjar A, Ilbey S, Sawiak S, Shi R, Chiew M, Emir U. Ultra-short T 2 components imaging of the whole brain using 3D dual-echo UTE MRI with rosette k-space pattern. Magn Reson Med 2023; 89:508-521. [PMID: 36161728 PMCID: PMC9712161 DOI: 10.1002/mrm.29451] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 07/26/2022] [Accepted: 08/22/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE This study aimed to develop a new 3D dual-echo rosette k-space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra-short transverse relaxation time (uT2 ) of brain was acquired to test the performance of the proposed UTE sequence. THEORY AND METHODS The rosette trajectory was developed based on rotations of a "petal-like" pattern in the kx -ky plane, with oscillated extensions in the kz -direction for 3D coverage. Five healthy volunteers underwent 10 dual-echo 3D rosette UTE scans with various TEs. Dual-exponential complex model fitting was performed on the magnitude data to separate uT2 signals, with the output of uT2 fraction, uT2 value, and long-T2 value. RESULTS The 3D rosette dual-echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT2 fraction values than gray matter (10.9% ± 1.9% vs. 5.7% ± 2.4%). The uT2 value was approximately 0.10 ms in white matter . CONCLUSION The higher uT2 fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.
Collapse
Affiliation(s)
- Xin Shen
- Weldon School of Biomedical Engineering, Purdue University
| | - Ali Caglar Özen
- Department of Radiology, Medical Physics, Medical Center–University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg
| | - Antonia Sunjar
- Weldon School of Biomedical Engineering, Purdue University
| | - Serhat Ilbey
- Department of Radiology, Medical Physics, Medical Center–University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg
| | - Stephen Sawiak
- Department of Clinical Neurosciences, University of Cambridge, UK,Department of Psychology, University of Cambridge, UK
| | - Riyi Shi
- Weldon School of Biomedical Engineering, Purdue University,College of Veterinary Medicine, Purdue University
| | - Mark Chiew
- Wellcome Centre for Integrative Neuroimaging, University of Oxford, UK
| | - Uzay Emir
- Weldon School of Biomedical Engineering, Purdue University,Health Science Department, Purdue University
| |
Collapse
|