1
|
Queissert F, Bruecher B, Schrader AJ. A New Proximal Adjustable Sling ATOMS SSP ® Implantation Technique with Focus on the Urethral Bulb: Lessons Learned from Revision Surgery. J Clin Med 2023; 12:4409. [PMID: 37445443 DOI: 10.3390/jcm12134409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 06/18/2023] [Accepted: 06/28/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND Adjustable sling ATOMS-SSP results in ventral compression of the urethra with favorable results in the treatment of men with mild to moderate stress incontinence. However, with transobturator tunneling and mesh fixation, the surgeon has a range of options, which leads to different results and sometimes unfavorable positioning of the silicone cushion. Using retrograde urethrography (RUG), we identified ATOMS patients with considerable misplacement. We then modified the implantation technique when we performed the revision, and now present here our first experiences with this new surgical technique. METHODS Patients after ATOMS-SSP implantation at our clinic were systematically subjected to a RUG if incontinence persisted after adjustments. In case of unfavorable positioning, a revision was performed with the aim of achieving an idealized urethroproximal position of the silicone pad. During follow-up, a repeat RUG was performed, and both subjective and objective outcome parameters were recorded. RESULTS Four men met the above criteria and underwent revision with reimplantation using our new technique. All patients postoperatively experienced significantly improved continence. RUGs demonstrated an ideal ATOMS position immediately below the proximal bulbar urethra. CONCLUSIONS Our proximal implantation technique, presented here for the first time, allows optimal positioning of the ATOMS SSP, which is reflected in the objective parameters and RUG. Its use in primary implantation should also be considered and an expansion to the indication of severe stress incontinence seems possible, but this should only be done in studies.
Collapse
Affiliation(s)
- Fabian Queissert
- Clinic for Urology and Pediatric Urology, University Hospital Muenster, 48149 Münster, Germany
| | - Benedict Bruecher
- Clinic for Urology and Pediatric Urology, University Hospital Muenster, 48149 Münster, Germany
| | - Andres J Schrader
- Clinic for Urology and Pediatric Urology, University Hospital Muenster, 48149 Münster, Germany
| |
Collapse
|
2
|
Téllez C, Szczesniewski J, Virseda-Chamorro M, Arance I, Angulo JC. Update on Adjustable Trans-Obturator Male System (ATOMS) for Male Incontinence after Prostate Cancer Surgery. Curr Oncol 2023; 30:4153-4165. [PMID: 37185429 PMCID: PMC10136884 DOI: 10.3390/curroncol30040316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 04/03/2023] [Accepted: 04/10/2023] [Indexed: 05/17/2023] Open
Abstract
(1) Background: The adjustable trans-obturator male system (ATOMS) is a surgical device developed to treat post-prostatectomy incontinence (PPI) after prostate cancer treatment. We review the current literature on this anti-incontinence device with the intention of assessing the effectiveness, safety and duration of the silicone-covered scrotal port (SSP) ATOMS, the only generation of the device that is currently available. (2) Material and Methods: Non-systematic literature review is performed. Forty-eight full-text articles are assessed for eligibility. Case reports, expert opinions or commentaries without specific data reported (n = 6), studies with patients who underwent intervention before 2014 (IP or SP ATOMS; n = 10), and studies with incontinence after transurethral resection of the prostate (TUR-P; n = 2) are excluded for analysis. Thirty studies with SSP ATOMS are included in a qualitative synthesis that incorporates systematic reviews (n = 3), articles partially overlapping with other previously published studies (e.g., follow-up or series updates; n = 9), and studies focusing on specific populations (n = 8). Only articles revealing outcomes of SSP ATOMS were included in the quantitative synthesis of results (n = 10). (3) Results: the pooled data of 1515 patients from the 10 studies with SSP ATOMS confirmed very satisfactory results with this device after adjustment: dry rate: 63-82%, improved rate: 85-100%, complication rate: 7-33%, device infection rate: 2.7-6.2% and explant rate: 0-19%. The durability of the device is reassuring, with 89% of devices in place 5 years after implantation. (4) Conclusion: Despite the absence of randomized controlled studies, the literature findings confirm results of SSP ATOMS appear equivalent to those of artificial urinary sphincters (AUSs) in terms of continence, satisfaction and complications, but with a lower rate of revision in the long-term. A prospective study identified that patients with daily pad test results <900 mL and a Male Stress Incontinence Grading Scale (MSIGS) of not 4 (i.e., early and persistent stream or urine loss) are the best candidates. Future studies centered on the elder population at higher risk of impaired cognitive ability and in patients including radiation as prostate cancer treatment are needed.
Collapse
Affiliation(s)
- Carlos Téllez
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| | - Juliusz Szczesniewski
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| | - Miguel Virseda-Chamorro
- Urology Department, Hospital Nacional de Parapléjicos, Carretera de la Peraleda, S/N, 45004 Toledo, Spain
| | - Ignacio Arance
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| | - Javier C Angulo
- Clinical Department, Faculty of Biomedical Sciences, Universidad Europea, 28805 Madrid, Spain
- Urology Department, Hospital Universitario de Getafe, 28805 Madrid, Spain
| |
Collapse
|
3
|
Refined Nomogram Incorporating Standing Cough Test Improves Prediction of Adjustable Trans-Obturator Male System (ATOMS) Success to Treat Post-Prostatectomy Male Stress Incontinence. J Pers Med 2022; 12:jpm12010094. [PMID: 35055409 PMCID: PMC8780728 DOI: 10.3390/jpm12010094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 01/06/2022] [Accepted: 01/09/2022] [Indexed: 02/07/2023] Open
Abstract
(1) Background: The adjustable transobturator male system (ATOMS) device serves to treat post-prostatectomy incontinence, as it enhances residual urinary sphincteric function by dorsal compression of the bulbar urethra. We investigated the clinical parameters affecting continence recovery using this device and developed a decision aid to predict success. (2) Methods: We reviewed consecutive men treated with first-time ATOMS for post-prostatectomy incontinence from 2014 to 2021 at our institution. Patient demographics, reported pads per day (PPD), 24-h pad-test and Standing Cough Test (SCT), results’ grades 1–4, according to Male Stress Incontinence Grading Scale (MSIGS), and the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) questionnaire were assessed. Treatment success was defined as no pads or a single PPD with ≤20-mL 24-h pad-test. Logistic regression was performed using a stepwise model (entry 0.15 and stay criterium 0.1) to evaluate independent variables’ determinant of dryness. Receiver-operating characteristic (ROC) curves for predictive variables were evaluated and their area under curve (AUC) was compared. A nomogram was generated and internally validated to predict probability of treatment success. (3) Results: Overall, 149 men (median age 70 years, IQR 7) were evaluated with a median follow-up of 45 months (IQR 26). Twelve patients (8%) had previous devices for incontinence, and 21 (14.1%) had pelvic radiation. Thirty-five men (23.5%) did not achieve continence after ATOMS adjustment (use of no or one security PPD with ≤20-mL 24-h pad-test). In univariate analysis, Charlson comorbidity index (p = 0.0412), previous urethroplasty (p = 0.0187), baseline PPD (p < 0.0001), 24-h pad-test (p < 0.0001), MSIGS (p < 0.0001), and ICIQ-SF questionnaire score (p < 0.0001) predicted ATOMS failure. In a multivariable model, 24-h pad-test (p = 0.0031), MSIGS (p = 0.0244), and radiotherapy (p = 0.0216) were independent variables, with AUC 0.8221. The association of MSIGS and 24-h pad-test was the superior combination (AUC 0.8236). A nomogram to predict the probability of ATOMS failure using the independent variables identified was proposed. (4) Conclusions: Several variables were identified as predictive of success for ATOMS using clinical history, physical examination (MSIGS), and factors that evaluate urine loss severity (PPD, 24-h pad-test, and ICIQ-SF questionnaire). MSIGS adds prognostic value to 24-h pad-test in assessing success of ATOMS device to treat post-prostatectomy incontinence. A nomogram was proposed to calculate the risk of ATOMS failure, which could be of interest to personalize the decision to use this device or not in the individual patient.
Collapse
|
4
|
Ruiz S, Virseda-Chamorro M, Salinas J, Queissert F, Arance I, Angulo JC. Influence of ATOMS implant on the voiding phase of patients with post-prostatectomy urinary incontinence. Neurourol Urodyn 2021; 41:609-615. [PMID: 34969148 DOI: 10.1002/nau.24856] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 09/12/2021] [Accepted: 11/29/2021] [Indexed: 11/10/2022]
Abstract
OBJECTIVE To assess changes in voiding phase, especially urethral resistance after post-prostatectomy urinary incontinence (PPI) treatment with the Adjustable TransObturator Male System (ATOMS). MATERIAL AND METHODS A longitudinal prospective study was performed on 45 men treated with ATOMS for PPI, with the intention to evaluate the changes produced by the implant on the voiding phase. Patients with preoperative urodynamic study were offered postoperative urodynamic evaluation, and both studies were compared. The following urodynamic date were evaluated: maximum voiding detrusor pressure, detrusor pressure at maximum flow rate, maximum flow rate (Qmax), voiding volume, post-void residue, bladder outlet obstruction index (BOOI), urethral resistance factor (URA), and bladder contractility index (BCI). The statistical analysis used were the mean comparison test for dependent groups (Student's t test) for parametric variables and the Wilcoxon test for non-parametric variables. The signification level was set at 95% bilateral. RESULTS A total of 37 patients (82.2%) used zero pads/day at the time of urodynamic postoperative evaluation and pad-test evolved from 592 ± 289 ml baseline to 25 ± 40 ml (p = 0.0001). Significant differences were observed in Qmax (15 ± 8.3 before and 11 ± 8.3 after surgery; p = 0.008), voiding volume (282 ± 130.7 before and 184 ± 99.92 after surgery). BOOI (-12 ± 23.9 before and -2 ± 21.4 after surgery; p = 0.025) and BCI (93 ± 46.4 before and 76 ± 46.0 after surgery; p = 0.044). In no case did we observe postoperative bladder outlet obstruction, according to URA parameter below 29 cm H2 O in all cases. There was not a significant variation either in post-void urinary residual volume (15 ± 47.4 before and 14 ± 24.2 after surgery, p = 0.867). CONCLUSIONS The ATOMS implant induces a decrease of Qmax, voided volume, and bladder contractility and an increase of BOOI. However, our findings suggest that ATOMS device does not cause bladder outlet obstruction.
Collapse
Affiliation(s)
- Sonia Ruiz
- Departamento Clinico, Facultad de Ciencias Biomédicas y de la Salud, Universidad Europea de Madrid, Madrid, Spain.,Servicio de Urología, Hospital Universitario de Getafe, Getafe, Madrid, Spain
| | | | - Jesús Salinas
- Servicio de Urología, Hospital Clínico San Carlos, Madrid, Spain
| | - Fabian Queissert
- Department of Urology and Pediatric Urology, University Hospital Muenster, Muenster, Germany
| | - Ignacio Arance
- Departamento Clinico, Facultad de Ciencias Biomédicas y de la Salud, Universidad Europea de Madrid, Madrid, Spain.,Servicio de Urología, Hospital Universitario de Getafe, Getafe, Madrid, Spain
| | - Javier C Angulo
- Departamento Clinico, Facultad de Ciencias Biomédicas y de la Salud, Universidad Europea de Madrid, Madrid, Spain.,Servicio de Urología, Hospital Universitario de Getafe, Getafe, Madrid, Spain
| |
Collapse
|
5
|
Angulo JC, Schönburg S, Giammò A, Queissert F, Gonsior A, González-Enguita C, Martins FE, Rourke K, Cruz F. Artificial urinary sphincter or a second adjustable transobturator male system offer equivalent outcomes in patients whom required revision on the initial ATOMS device: An international multi-institutional experience. Neurourol Urodyn 2021; 40:897-909. [PMID: 33645867 DOI: 10.1002/nau.24646] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 02/05/2021] [Accepted: 02/14/2021] [Indexed: 11/11/2022]
Abstract
AIM To evaluate treatment options after surgical revision of adjustable transobturator male system (ATOMS) and the results of further incontinence implantation. MATERIALS AND METHODS A retrospective multicenter study evaluating patients with surgical revision of ATOMS in academic institutions. Causes and factors affecting revision-free interval were studied and also the frequency of device explant and placement of second ATOMS or artificial urinary sphincter (AUS) at surgeon discretion. Operative results, complications (Clavien-Dindo), and efficacy (postoperative pad-test, pad-count, patient satisfaction, and patient global impression of improvement [PGI-I scale]) of each treatment option were compared. RESULTS Seventy-eight out of 902 patients (8.65%) with ATOMS underwent surgical revision at 4.1 ± 2.4 years mean follow-up and 75 (8.3%) were explanted. The main causes for revision included persistence of incontinence (35.9%) and scrotal port erosion (34.6%). Independent risk factors of the shortened revision-free interval were previous anti-incontinence surgery (HR, 1.83; 95% CI, 1.06-3.16; p = 0.007) and port erosion (HR, 1.83; 95% CI, 1.06-3.16; p = 0.0027). Fifty-eight (6.4%) received a second implant: 31 repeated ATOMS and 27 AUS. Operative time was longer for AUS (p = .003). The visual analog scale of pain at hospital discharge (p = 0.837) and postoperative complications (p = 0.154) were equivalent. The predominant cuff size for AUS was 4.5 cm (59.3%). Mean follow-up after the second implant was 29.1 ± 25.8 months. Postoperative efficacy of secondary treatment results favored ATOMS based on pad-test (p = 0.016), pad-count (p = 0.029), patient satisfaction (p = 0.04), and PGI-I (p = 0.025). CONCLUSIONS ATOMS surgical revision due to different reasons generally leads to device explant. Rescue treatment is possible with ATOMS or AUS. No difference in postoperative complications was detected between secondary devices, but efficacy favors repeating ATOMS implantation.
Collapse
Affiliation(s)
- Javier C Angulo
- Clinical Department, Universidad Europea de Madrid, Hospital Universitario de Getafe, Madrid, Spain
| | - Sandra Schönburg
- Department of Urology and Kidney Transplantation, Martin Luther University, Halle (Saale), Germany
| | - Alessandro Giammò
- Department of Neuro-Urology, CTO/Spinal Cord Unit, AOU Città della Salute e della Scienza di Torino, Turin, Italy
| | - Fabian Queissert
- Department of Urology, Universitätsklinikum Münster, Münster, Germany
| | - Andreas Gonsior
- Klinik und Poliklinik für Urologie, University of Leipzig, Leipzig, Germany
| | | | - Francisco E Martins
- Centro Hospitalar Universitário de Lisboa Norte, Hospital Santa María, Lisboa, Portugal
| | - Keith Rourke
- Department of Urology, Alberta University, Edmonton, Alberta, Canada
| | - Francisco Cruz
- Department of Urology, Centro Hospitalar São João, Oporto, Portugal
| |
Collapse
|
6
|
Angulo JC, Ruiz S, Lozano M, Arance I, Virseda M, Lora D. Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and male Readjustment Mechanical External (REMEEX) system for post-prostatectomy incontinence. World J Urol 2020; 39:1083-1092. [PMID: 32529450 DOI: 10.1007/s00345-020-03300-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 06/03/2020] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE To assess the efficacy and safety of Adjustable Transobturator Male System (ATOMS) compared to male Readjustment Mechanical External (REMEEX) system for post-prostatectomy incontinence (PPI). MATERIAL AND METHODS A systematic review and meta-analysis on adjustable device ATOMS compared to male REMEEX is presented. Studies on female or neurogenic incontinence were excluded. Primary objectives were evaluation of dryness (the proportion of patients with no-pad or one safety pad/day after device adjustment) and improvement between devices. Secondary objectives were complications and explant rate. They were estimated using a random-effect model. Statistical heterogeneity among studies was assessed using Cochran's Q test, Higgins's I2 statistics and tau2. RESULTS Combined data of 29 observational studies with 1919 patients showed an equivalent proportion of patients treated with radical prostatectomy (p = .125) and previous radiation (p = .126). Dryness rate was 69.3% for ATOMS and 53.4% for male REEMEX (p = .008). Improvement rate was 90.8% for ATOMS and 80.2% for REMEEX (p = .007). Complication rate was 18.9% for ATOMS and 35.8% for REMEEX (p = .096) and explant rate was 5.5% for ATOMS and 13.9% for REMEEX (p = .027). Significant heterogeneity was evidenced, due to absence of randomized studies, variable incontinence severity baseline, difficulties for a common reporting of complications and difference in the follow-up. Differences observed between devices remained statistically significant when only studies with silicone-covered scrotal port (SSP) ATOMS and male REMEEX system II were considered. CONCLUSIONS Despite the absence of direct comparison and the limitations observed ATOMS appears more effective than male REMEEX to treat PPI, and with less explant rate as reported in the literature.
Collapse
Affiliation(s)
- Javier C Angulo
- Departamento Clínico, Universidad Europea de Madrid, Madrid, Spain. .,Servicio de Urología, Hospital Universitario de Getafe, Carretera de Toledo Km 12.5, 28905, Madrid, Spain.
| | - Sonia Ruiz
- Departamento Clínico, Universidad Europea de Madrid, Madrid, Spain.,Servicio de Urología, Hospital Universitario de Getafe, Carretera de Toledo Km 12.5, 28905, Madrid, Spain
| | - Martín Lozano
- Departamento Clínico, Universidad Europea de Madrid, Madrid, Spain.,Servicio de Urología, Hospital Universitario de Getafe, Carretera de Toledo Km 12.5, 28905, Madrid, Spain
| | - Ignacio Arance
- Departamento Clínico, Universidad Europea de Madrid, Madrid, Spain.,Servicio de Urología, Hospital Universitario de Getafe, Carretera de Toledo Km 12.5, 28905, Madrid, Spain
| | - Miguel Virseda
- Departamento Clínico, Universidad Europea de Madrid, Madrid, Spain.,Servicio de Urología, Hospital Universitario de Getafe, Carretera de Toledo Km 12.5, 28905, Madrid, Spain
| | - David Lora
- Instituto de Investigación Sanitaria Hospital "12 de Octubre" (i+12), CIBER de Epidemiología y Salud Pública (CIBERESP), Universidad Complutense de Madrid, 28041, Madrid, Spain
| |
Collapse
|