1
|
Athertya JS, Suprana A, Lo J, Lombardi AF, Moazamian D, Chang EY, Du J, Ma Y. Quantitative ultrashort echo time MR imaging of knee osteochondral junction: An ex vivo feasibility study. NMR IN BIOMEDICINE 2024:e5253. [PMID: 39197467 DOI: 10.1002/nbm.5253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 08/12/2024] [Accepted: 08/19/2024] [Indexed: 09/01/2024]
Abstract
Compositional changes can occur in the osteochondral junction (OCJ) during the early stages and progressive disease evolution of knee osteoarthritis (OA). However, conventional magnetic resonance imaging (MRI) sequences are not able to image these regions efficiently because of the OCJ region's rapid signal decay. The development of new sequences able to image and quantify OCJ region is therefore highly desirable. We developed a comprehensive ultrashort echo time (UTE) MRI protocol for quantitative assessment of OCJ region in the knee joint, including UTE variable flip angle technique for T1 mapping, UTE magnetization transfer (UTE-MT) modeling for macromolecular proton fraction (MMF) mapping, UTE adiabatic T1ρ (UTE-AdiabT1ρ) sequence for T1ρ mapping, and multi-echo UTE sequence for T2* mapping. B1 mapping based on the UTE actual flip angle technique was utilized for B1 correction in T1, MMF, and T1ρ measurements. Ten normal and one abnormal cadaveric human knee joints were scanned on a 3T clinical MRI scanner to investigate the feasibility of OCJ imaging using the proposed protocol. Volumetric T1, MMF, T1ρ, and T2* maps of the OCJ, as well as the superficial and full-thickness cartilage regions, were successfully produced using the quantitative UTE imaging protocol. Significantly lower T1, T1ρ, and T2* relaxation times were observed in the OCJ region compared with those observed in both the superficial and full-thickness cartilage regions, whereas MMF showed significantly higher values in the OCJ region. In addition, all four UTE biomarkers showed substantial differences in the OCJ region between normal and abnormal knees. These results indicate that the newly developed 3D quantitative UTE imaging techniques are feasible for T1, MMF, T1ρ, and T2* mapping of knee OCJ, representative of a promising approach for the evaluation of compositional changes in early knee OA.
Collapse
Affiliation(s)
- Jiyo S Athertya
- Department of Radiology, University of California San Diego, San Diego, California, USA
| | - Arya Suprana
- Department of Radiology, University of California San Diego, San Diego, California, USA
- Department of Bioengineering, University of California San Diego, San Diego, California, USA
| | - James Lo
- Department of Radiology, University of California San Diego, San Diego, California, USA
- Department of Bioengineering, University of California San Diego, San Diego, California, USA
| | - Alecio F Lombardi
- Department of Radiology, University of California San Diego, San Diego, California, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, California, USA
| | - Dina Moazamian
- Department of Radiology, University of California San Diego, San Diego, California, USA
| | - Eric Y Chang
- Department of Radiology, University of California San Diego, San Diego, California, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, California, USA
| | - Jiang Du
- Department of Radiology, University of California San Diego, San Diego, California, USA
- Department of Bioengineering, University of California San Diego, San Diego, California, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, California, USA
| | - Yajun Ma
- Department of Radiology, University of California San Diego, San Diego, California, USA
| |
Collapse
|
2
|
Athertya JS, Lo J, Chen X, Shin SH, Malhi BS, Jerban S, Ji Y, Sedaghat S, Yoshioka H, Du J, Guma M, Chang EY, Ma Y. High contrast cartilaginous endplate imaging in spine using three dimensional dual-inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequence. Skeletal Radiol 2024; 53:881-890. [PMID: 37935923 PMCID: PMC10973042 DOI: 10.1007/s00256-023-04503-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/14/2023] [Accepted: 10/29/2023] [Indexed: 11/09/2023]
Abstract
PURPOSE To investigate the feasibility and application of a novel imaging technique, a three-dimensional dual adiabatic inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequence, for high contrast assessment of cartilaginous endplate (CEP) imaging with head-to-head comparisons between other UTE imaging techniques. METHOD The DIR-UTE sequence employs two narrow-band adiabatic full passage (AFP) pulses to suppress signals from long T2 water (e.g., nucleus pulposus (NP)) and bone marrow fat (BMF) independently, followed by multispoke UTE acquisition to detect signals from the CEP with short T2 relaxation times. The DIR-UTE sequence, in addition to three other UTE sequences namely, an IR-prepared and fat-saturated UTE (IR-FS-UTE), a T1-weighted and fat-saturated UTE sequence (T1w-FS-UTE), and a fat-saturated UTE (FS-UTE) was used for MR imaging on a 3 T scanner to image six asymptomatic volunteers, six patients with low back pain, as well as a human cadaveric specimen. The contrast-to-noise ratio of the CEP relative to the adjacent structures-specifically the NP and BMF-was then compared from the acquired images across the different UTE sequences. RESULTS For asymptomatic volunteers, the DIR-UTE sequence showed significantly higher contrast-to-noise ratio values between the CEP and BMF (CNRCEP-BMF) (19.9 ± 3.0) and between the CEP and NP (CNRCEP-NP) (23.1 ± 1.7) compared to IR-FS-UTE (CNRCEP-BMF: 17.3 ± 1.2 and CNRCEP-NP: 19.1 ± 1.8), T1w-FS-UTE (CNRCEP-BMF: 9.0 ± 2.7 and CNRCEP-NP: 10.4 ± 3.5), and FS-UTE (CNRCEP-BMF: 7.7 ± 2.2 and CNRCEP-NP: 5.8 ± 2.4) for asymptomatic volunteers (all P-values < 0.001). For the spine sample and patients with low back pain, the DIR-UTE technique detected abnormalities such as irregularities and focal defects in the CEP regions. CONCLUSION The 3D DIR-UTE sequence is able to provide high-contrast volumetric CEP imaging for human spines on a clinical 3 T scanner.
Collapse
Affiliation(s)
- Jiyo S Athertya
- Department of Radiology, University of California San Diego, San Diego, CA, USA
| | - James Lo
- Department of Radiology, University of California San Diego, San Diego, CA, USA
- Department of Bioengineering, University of California San Diego, San Diego, CA, USA
| | - Xiaojun Chen
- Department of Radiology, University of California San Diego, San Diego, CA, USA
| | - Soo Hyun Shin
- Department of Radiology, University of California San Diego, San Diego, CA, USA
| | | | - Saeed Jerban
- Department of Radiology, University of California San Diego, San Diego, CA, USA
| | - Yang Ji
- Department of Radiology, University of California San Diego, San Diego, CA, USA
| | - Sam Sedaghat
- Department of Radiology, University of California San Diego, San Diego, CA, USA
| | - Hiroshi Yoshioka
- Department of Radiological Sciences, University of California Irvine, Irvine, CA, USA
| | - Jiang Du
- Department of Radiology, University of California San Diego, San Diego, CA, USA
- Department of Bioengineering, University of California San Diego, San Diego, CA, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA
| | - Monica Guma
- Department of Medicine, University of California San Diego, San Diego, CA, USA
- Medicine Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA
| | - Eric Y Chang
- Department of Radiology, University of California San Diego, San Diego, CA, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA
| | - Yajun Ma
- Department of Radiology, University of California San Diego, San Diego, CA, USA.
| |
Collapse
|
3
|
Cheng KY, Moazamian D, Ma Y, Jang H, Jerban S, Du J, Chung CB. Clinical application of ultrashort echo time (UTE) and zero echo time (ZTE) magnetic resonance (MR) imaging in the evaluation of osteoarthritis. Skeletal Radiol 2023; 52:2149-2157. [PMID: 36607355 PMCID: PMC10323038 DOI: 10.1007/s00256-022-04269-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 12/13/2022] [Accepted: 12/13/2022] [Indexed: 01/07/2023]
Abstract
Novel compositional magnetic resonance (MR) imaging techniques have allowed for both the qualitative and quantitative assessments of tissue changes in osteoarthritis, many of which are difficult to characterize on conventional MR imaging. Ultrashort echo time (UTE) and zero echo time (ZTE) MR imaging have not been broadly implemented clinically but have several applications that leverage contrast mechanisms for morphologic evaluation of bone and soft tissue, as well as biochemical assessment in various stages of osteoarthritis progression. Many of the musculoskeletal tissues implicated in the initiation and progression of osteoarthritis are short T2 in nature, appearing dark as signal has already decayed to its minimum when image sampling starts. UTE and ZTE MR imaging allow for the qualitative and quantitative assessments of these short T2 tissues (bone, tendon, calcified cartilage, meniscus, and ligament) with both structural and functional reference standards described in the literature [1-3]. This review will describe applications of UTE and ZTE MR imaging in musculoskeletal tissues focusing on its role in knee osteoarthritis. While the review will address tissue-specific applications of these sequences, it is understood that osteoarthritis is a whole joint process with involvement and interdependence of all tissues. KEY POINTS: • UTE MR imaging allows for the qualitative and quantitative evaluation of short T2 tissues (bone, calcified cartilage, and meniscus), enabling identification of both early degenerative changes and subclinical injuries that may predispose to osteoarthritis. • ZTE MR imaging allows for the detection of signal from bone, which has some of the shortest T2 values, and generates tissue contrast similar to CT, potentially obviating the need for CT in the assessment of osseous features of osteoarthritis.
Collapse
Affiliation(s)
- Karen Y Cheng
- Department of Radiology, University of California, San Diego, CA, USA
| | - Dina Moazamian
- Department of Radiology, University of California, San Diego, CA, USA
| | - Yajun Ma
- Department of Radiology, University of California, San Diego, CA, USA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, CA, USA
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, CA, USA
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA
- Department of Orthopedic Surgery, University of California, San Diego, San Diego, CA, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, CA, USA
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA
- Department of Bioengineering, University of California, San Diego, CA, USA
| | - Christine B Chung
- Department of Radiology, University of California, San Diego, CA, USA.
- Department of Radiology, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA.
| |
Collapse
|
4
|
Hu Y, Xu J, Zhou R, Xu Q, Sun S, Wang W, Chen H. The value of magnetic resonance ultrashort echo time imaging to evaluate non-calcified cartilage of the knee joint and its damage. Heliyon 2023; 9:e14120. [PMID: 36915568 PMCID: PMC10006742 DOI: 10.1016/j.heliyon.2023.e14120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 03/05/2023] Open
Abstract
Objectives To image knee osteochondral specimens using magnetic resonance (MR) ultrashort echo time imaging with pointwise encoding time reduction with radial acquisition combined fat suppression (PETRA-FS) sequence to determine whether it can reveal non-calcified cartilage, including the deep radial layer, and to assess its effectiveness in cartilage damage diagnosis. Materials and methods PETRA-FS imaging was performed on 58 osteochondral specimens of the lower femur and upper tibia to observe depth of cartilage damage, combined with histological results to observe signal intensity composition. Sensitivity, specificity, and reliability of PETRA-FS sequence for diagnosing cartilage damage were evaluated using histological results as the gold standard. Diagnostic efficacy was assessed using receiver operating characteristic (ROC) curve. Results MR ultrashort echo time imaging PETRA-FS sequence showed non-calcified cartilage, including tangential, transitional, and radial layers, which showed a high signal. PETRA-FS sequence showed 37 cases of cartilage damage and 21 cases of no damage among 58 specimens, kappa value of 0.75. Histological analysis of the 58 osteochondral specimens revealed 38 cases of cartilage injury and 20 cases of undamaged cartilage. Using histological results as the gold standard, PETRA-FS sequence had a sensitivity of 87.00%, specificity of 80.00%, kappa value of 0.81, and an area under the ROC curve (AUC) of 0.83 for cartilage injury diagnosis. Conclusion MR ultrashort echo time imaging PETRA-FS sequence can show non-calcified cartilage, including the deep radial layer (which cannot be shown by conventional MR), by exhibiting a high signal in knee osteo-chondral specimens. Thus, PETRA-FS sequences may have important diagnostic value for cartilage injury diagnosis.
Collapse
Affiliation(s)
- Yawen Hu
- Department of Radiology, The Affliated Hospital of Qingdao University Qingdao, 266003, China
| | - Jun Xu
- Department of Radiology, The Affliated Hospital of Qingdao University Qingdao, 266003, China
| | - Ruizhi Zhou
- Department of Radiology, The Affliated Hospital of Qingdao University Qingdao, 266003, China
| | - Qi Xu
- Department of Radiology, The Affliated Hospital of Qingdao University Qingdao, 266003, China
| | - Shiqing Sun
- Department of Radiology, The Affliated Hospital of Qingdao University Qingdao, 266003, China
| | - Wenzhe Wang
- Department of Joint Surgery, The Affliated Hospital of Qingdao University Qingdao, 266003, China
| | - Haisong Chen
- Department of Radiology, The Affliated Hospital of Qingdao University Qingdao, 266003, China
- Corresponding author.
| |
Collapse
|
5
|
Lombardi AF, Guma M, Chung CB, Chang EY, Du J, Ma YJ. Ultrashort echo time magnetic resonance imaging of the osteochondral junction. NMR IN BIOMEDICINE 2023; 36:e4843. [PMID: 36264245 PMCID: PMC9845195 DOI: 10.1002/nbm.4843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 09/20/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
Osteoarthritis is a common chronic degenerative disease that causes pain and disability with increasing incidence worldwide. The osteochondral junction is a dynamic region of the joint that is associated with the early development and progression of osteoarthritis. Despite the substantial advances achieved in the imaging of cartilage and application to osteoarthritis in recent years, the osteochondral junction has received limited attention. This is primarily related to technical limitations encountered with conventional MR sequences that are relatively insensitive to short T2 tissues and the rapid signal decay that characterizes these tissues. MR sequences with ultrashort echo time (UTE) are of great interest because they can provide images of high resolution and contrast in this region. Here, we briefly review the anatomy and function of cartilage, focusing on the osteochondral junction. We also review basic concepts and recent applications of UTE MR sequences focusing on the osteochondral junction.
Collapse
Affiliation(s)
- Alecio F. Lombardi
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Monica Guma
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
- Department of Medicine, University of California San Diego, CA, United States
| | - Christine B. Chung
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Eric Y. Chang
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Jiang Du
- Department of Radiology, University of California San Diego, CA, United States
| | - Ya-Jun Ma
- Department of Radiology, University of California San Diego, CA, United States
| |
Collapse
|
6
|
Ma Y, Jang H, Jerban S, Chang EY, Chung CB, Bydder GM, Du J. Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications. APPLIED PHYSICS REVIEWS 2022; 9:041303. [PMID: 36467869 PMCID: PMC9677812 DOI: 10.1063/5.0086459] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 09/12/2022] [Indexed: 05/25/2023]
Abstract
Magnetic resonance imaging (MRI) uses a large magnetic field and radio waves to generate images of tissues in the body. Conventional MRI techniques have been developed to image and quantify tissues and fluids with long transverse relaxation times (T2s), such as muscle, cartilage, liver, white matter, gray matter, spinal cord, and cerebrospinal fluid. However, the body also contains many tissues and tissue components such as the osteochondral junction, menisci, ligaments, tendons, bone, lung parenchyma, and myelin, which have short or ultrashort T2s. After radio frequency excitation, their transverse magnetizations typically decay to zero or near zero before the receiving mode is enabled for spatial encoding with conventional MR imaging. As a result, these tissues appear dark, and their MR properties are inaccessible. However, when ultrashort echo times (UTEs) are used, signals can be detected from these tissues before they decay to zero. This review summarizes recent technical developments in UTE MRI of tissues with short and ultrashort T2 relaxation times. A series of UTE MRI techniques for high-resolution morphological and quantitative imaging of these short-T2 tissues are discussed. Applications of UTE imaging in the musculoskeletal, nervous, respiratory, gastrointestinal, and cardiovascular systems of the body are included.
Collapse
Affiliation(s)
- Yajun Ma
- Department of Radiology, University of California, San Diego, California 92037, USA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, California 92037, USA
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, California 92037, USA
| | | | | | - Graeme M Bydder
- Department of Radiology, University of California, San Diego, California 92037, USA
| | - Jiang Du
- Author to whom correspondence should be addressed:. Tel.: (858) 246-2248, Fax: (858) 246-2221
| |
Collapse
|
7
|
Evans LAE, Pitsillides AA. Structural clues to articular calcified cartilage function: A descriptive review of this crucial interface tissue. J Anat 2022; 241:875-895. [PMID: 35866709 PMCID: PMC9482704 DOI: 10.1111/joa.13728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 06/26/2022] [Accepted: 06/30/2022] [Indexed: 11/26/2022] Open
Abstract
Articular calcified cartilage (ACC) has been dismissed, by some, as a remnant of endochondral ossification without functional relevance to joint articulation or weight-bearing. Recent research indicates that morphologic and metabolic ACC features may be important, reflecting knee joint osteoarthritis (OA) predisposition. ACC is less investigated than neighbouring joint tissues, with its component chondrocytes and mineralised matrix often being either ignored or integrated into analyses of hyaline articular cartilage and subchondral bone tissue respectively. Anatomical variation in ACC is recognised between species, individuals and age groups, but the selective pressures underlying this variation are unknown. Consequently, optimal ACC biomechanical features are also unknown as are any potential locomotory roles. This review collates descriptions of ACC anatomy and biology in health and disease, with a view to revealing its structure/function relationship and highlighting potential future research avenues. Mouse models of healthy and OA joint ageing have shown disparities in ACC load-induced deformations at the knee joint. This raises the hypothesis that ACC response to locomotor forces over time may influence, or even underlie, the bony and hyaline cartilage symptoms characteristic of OA. To effectively investigate the ACC, greater resolution of joint imaging and merging of hierarchical scale data will be required. An appreciation of OA as a 'whole joint disease' is expanding, as is the possibility that the ACC may be a key player in healthy ageing and in the transition to OA joint pathology.
Collapse
Affiliation(s)
- Lucinda A. E. Evans
- Department of Comparative Biomedical SciencesRoyal Veterinary College, University of LondonLondonUK
| | - Andrew A. Pitsillides
- Department of Comparative Biomedical SciencesRoyal Veterinary College, University of LondonLondonUK
| |
Collapse
|
8
|
Su X, Zhang Y, Gao Q, Liang Z, Wan L, Zhang L, Tang G. Preliminary study on the assessment of early cartilage degeneration by quantitative ultrashort echo time magnetic resonance imaging in vivo. Quant Imaging Med Surg 2022; 12:3803-3812. [PMID: 35782245 PMCID: PMC9246734 DOI: 10.21037/qims-21-1181] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 04/14/2022] [Indexed: 12/31/2023]
Abstract
BACKGROUND To investigate the feasibility of quantitative ultrashort echo time magnetic resonance imaging (UTE-MRI) techniques for assessing early cartilage degeneration in vivo. METHODS A total of 46 patients with knee pain due to osteoarthritis (OA) as the main complaint were recruited into the study. We performed MRI examinations with different quantitative UTE-MRI techniques, including UTE-based magnetization transfer (MT), UTE-adiabaticT1ρ, and UTE-T2* mapping on a 3.0T clinical magnetic resonance (MR) scanner (MR750; GE Healthcare, Milwaukee, WI, USA). Three regions of interest (ROIs) were manually drawn on the medial and lateral femoral condyles and the corresponding medial and lateral tibial plateaus, respectively. A total of 561 ROIs (12 ROIs for each knee) were finally included and divided into 3 groups according to the MRI Osteoarthritis Knee Score (MOAKS): normal (MOAKS 0, n=175), mild degeneration (MOAKS 1, n=283), and moderate degeneration (MOAKS 2, n=103). One-way analysis of variance (ANOVA) and Tamhane's T2 test were used to compare the differences of quantitative UTE-biomarkers among different groups. The analysis of Spearman's correlation was used to assess the correlation between the UTE-biomarkers and MOAKS grading. The diagnostic efficacy of different quantitative UTE-MRI techniques for detecting mild cartilage degeneration was evaluated using the receiver operating characteristic (ROC) curve. RESULTS The UTE-MT ratio (UTE-MTR) and the UTE-adiabatic T1ρ values had a moderate correlation with the MOAKS grading (r=-0.523, P<0.001; r=0.531, P<0.001, respectively), while the UTE-T2* was weakly correlated with the MOAKS grading (r=-0.396, P<0.001). For the normal group (MOAKS 0) and the mild group (MOAKS 1), the UTE-MTR values were 21.09%±3.03% and 17.30%±3.22%, respectively. The UTE-adiabatic T1ρ values were 30.43±6.26 ms and 35.05±8.78 ms for the normal group (MOAKS 0) and the mild group (MOAKS 1), respectively. With respect to the UTE-T2* values, the normal group (MOAKS 0) values were 21.49±3.96 ms and the mild group (MOAKS 1) values were 19.86±3.08 ms. All the differences between the 2 groups of the 3 UTE-MRI values were significant. The AUCs of the UTE-MTR, UTE-adiabatic T1ρ, and UTE-T2* mapping were 0.794, 0.732, and 0.651, respectively. CONCLUSIONS The quantitative UTE-MRI techniques (UTE-MT, UTE-adiabatic T1ρ, and UTE-T2* mapping) show great promise for assessing the early degeneration of articular cartilage in vivo, and the UTE-MT and UTE-adiabatic T1ρ values show better diagnostic efficacy than UTE-T2* mapping.
Collapse
Affiliation(s)
- Xiaolian Su
- Department of Radiology, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
| | - Yixuan Zhang
- Department of Radiology, Hebei Cangzhou Hospital of Integrated Traditional Chinese Medicine and Western Medicine, Cangzhou, China
| | - Qiuming Gao
- Department of Orthopedics, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
| | - Zonghui Liang
- Department of Radiology, Shanghai Jing’an District Central Hospital, Shanghai, China
| | - Lidi Wan
- Department of Radiology, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
| | - Lin Zhang
- Department of Radiology, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
| | - Guangyu Tang
- Department of Radiology, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
| |
Collapse
|
9
|
Wan L, Cheng X, Searleman AC, Ma YJ, Wong JH, Meyer RS, Du J, Tang G, Chang EY. Evaluation of enzymatic proteoglycan loss and collagen degradation in human articular cartilage using ultrashort echo time-based biomarkers: A feasibility study. NMR IN BIOMEDICINE 2022; 35:e4664. [PMID: 34904305 PMCID: PMC9042587 DOI: 10.1002/nbm.4664] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 11/19/2021] [Accepted: 11/20/2021] [Indexed: 05/02/2023]
Abstract
The objective of the current study was to investigate the feasibility of quantitative 3D ultrashort echo time (UTE)-based biomarkers in detecting proteoglycan (PG) loss and collagen degradation in human cartilage. A total of 104 cartilage samples were harvested for a trypsin digestion study (n = 44), and a sequential trypsin and collagenase digestion study (n = 60), respectively. Forty-four cartilage samples were randomly divided into a trypsin digestion group (tryp group) and a control group (phosphate-buffered saline [PBS] group) (n = 22 for each group) for the trypsin digestion experiment. The remaining 60 cartilage samples were divided equally into four groups (n = 15 for each group) for sequential trypsin and collagenase digestion, including PBS + Tris (incubated in PBS, then Tris buffer solution), PBS + 30 U col (incubated in PBS, then 30 U/ml collagenase [30 U col] with Tris buffer solution), tryp + 30 U col (incubated in trypsin solution, then 30 U/ml collagenase with Tris buffer solution), and tryp + Tris (incubated in trypsin solution, then Tris buffer solution). The 3D UTE-based MRI biomarkers included T1 , multiecho T2 *, adiabatic T1ρ (AdiabT1ρ ), magnetization transfer ratio (MTR), and modeling of macromolecular proton fraction (MMF). For each cartilage sample, UTE-based biomarkers (T1 , T2 *, AdiabT1ρ , MTR, and MMF) and sample weight were evaluated before and after treatment. PG and hydroxyproline assays were performed. Differences between groups and correlations were assessed. All the evaluated biomarkers were able to differentiate between healthy and degenerated cartilage in the trypsin digestion experiment, but only T1 and AdiabT1ρ were significantly correlated with the PG concentration in the digestion solution (p = 0.004 and p = 0.0001, respectively). In the sequential digestion experiment, no significant differences were found for T1 and AdiabT1ρ values between the PBS + Tris and PBS + 30 U col groups (p = 0.627 and p = 0.877, respectively), but T1 and AdiabT1ρ values increased significantly in the tryp + Tris (p = 0.031 and p = 0.024, respectively) and tryp + 30 U col groups (both p < 0.0001). Significant decreases in MMF and MTR were found in the tryp + 30 U col group compared with the PBS + Tris group (p = 0.002 and p = 0.001, respectively). It was concluded that AdiabT1ρ and T1 have the potential for detecting PG loss, while MMF and MTR are promising for the detection of collagen degradation in articular cartilage, which could facilitate earlier, noninvasive diagnosis of osteoarthritis.
Collapse
Affiliation(s)
- Lidi Wan
- Department of Radiology, University of California, San Diego, CA
- Department of Radiology, Tenth People’s Hospital of Tongji University, Shanghai, China
| | - Xin Cheng
- Department of Radiology, University of California, San Diego, CA
- Division of Histology and Embryology, Jinan University, Guangzhou, China
| | | | - Ya-Jun Ma
- Department of Radiology, University of California, San Diego, CA
| | - Jonathan H. Wong
- Department of Radiology, University of California, San Diego, CA
- Radiology Service, VA San Diego Healthcare System, San Diego, CA
| | - R. Scott Meyer
- Orthopaedic Surgery Service, VA San Diego Healthcare System, San Diego, CA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, CA
| | - Guangyu Tang
- Department of Radiology, Tenth People’s Hospital of Tongji University, Shanghai, China
| | - Eric Y. Chang
- Department of Radiology, University of California, San Diego, CA
- Radiology Service, VA San Diego Healthcare System, San Diego, CA
| |
Collapse
|
10
|
Lombardi AF, Ma Y, Jang H, Jerban S, Tang Q, Searleman AC, Meyer RS, Du J, Chang EY. AcidoCEST-UTE MRI Reveals an Acidic Microenvironment in Knee Osteoarthritis. Int J Mol Sci 2022; 23:4466. [PMID: 35457284 PMCID: PMC9027981 DOI: 10.3390/ijms23084466] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 04/08/2022] [Accepted: 04/13/2022] [Indexed: 02/01/2023] Open
Abstract
A relationship between an acidic pH in the joints, osteoarthritis (OA), and pain has been previously demonstrated. Acidosis Chemical Exchange Saturation Transfer (acidoCEST) indirectly measures the extracellular pH through the assessment of the exchange of protons between amide groups on iodinated contrast agents and bulk water. It is possible to estimate the extracellular pH in the osteoarthritic joint using acidoCEST MRI. However, conventional MR sequences cannot image deep layers of cartilage, meniscus, ligaments, and other musculoskeletal tissues that present with short echo time and fast signal decay. Ultrashort echo time (UTE) MRI, on the other hand, has been used successfully to image those joint tissues. Here, our goal is to compare the pH measured in the knee joints of volunteers without OA and patients with severe OA using acidoCEST-UTE MRI. Patients without knee OA and patients with severe OA were examined using acidoCEST-UTE MRI and the mean pH of cartilage, meniscus, and fluid was calculated. Additionally, the relationship between the pH measurements and the Knee Injury and Osteoarthritis Outcome Score (KOOS) was investigated. AcidoCEST-UTE MRI can detect significant differences in the pH of knee cartilage, meniscus, and fluid between joints without and with OA, with OA showing lower pH values. In addition, symptoms and knee-joint function become worse at lower pH measurements.
Collapse
Affiliation(s)
- Alecio F. Lombardi
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (E.Y.C.)
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| | - Yajun Ma
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| | - Hyungseok Jang
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| | - Saeed Jerban
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| | - Qingbo Tang
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (E.Y.C.)
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| | - Adam C. Searleman
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| | - Robert Scott Meyer
- Orthopaedic Surgery Service, Veterans Affairs San Diego Healthcare System, San Diego, CA 92161, USA;
| | - Jiang Du
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| | - Eric Y. Chang
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA 92161, USA; (Q.T.); (E.Y.C.)
- Department of Radiology, University of California San Diego, San Diego, CA 92161, USA; (Y.M.); (H.J.); (S.J.); (A.C.S.); (J.D.)
| |
Collapse
|
11
|
Afsahi AM, Sedaghat S, Moazamian D, Afsahi G, Athertya JS, Jang H, Ma YJ. Articular Cartilage Assessment Using Ultrashort Echo Time MRI: A Review. Front Endocrinol (Lausanne) 2022; 13:892961. [PMID: 35692400 PMCID: PMC9178905 DOI: 10.3389/fendo.2022.892961] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 04/14/2022] [Indexed: 01/05/2023] Open
Abstract
Articular cartilage is a major component of the human knee joint which may be affected by a variety of degenerative mechanisms associated with joint pathologies and/or the aging process. Ultrashort echo time (UTE) sequences with a TE less than 100 µs are capable of detecting signals from both fast- and slow-relaxing water protons in cartilage. This allows comprehensive evaluation of all the cartilage layers, especially for the short T2 layers which include the deep and calcified zones. Several ultrashort echo time (UTE) techniques have recently been developed for both morphological imaging and quantitative cartilage assessment. This review article summarizes the current catalog techniques based on UTE Magnetic Resonance Imaging (MRI) that have been utilized for such purposes in the human knee joint, such as T1, T2∗ , T1ρ, magnetization transfer (MT), double echo steady state (DESS), quantitative susceptibility mapping (QSM) and inversion recovery (IR). The contrast mechanisms as well as the advantages and disadvantages of these techniques are discussed.
Collapse
Affiliation(s)
- Amir Masoud Afsahi
- Department of Radiology, University of California San Diego, San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| | - Sam Sedaghat
- Department of Radiology, University of California San Diego, San Diego, CA, United States
| | - Dina Moazamian
- Department of Radiology, University of California San Diego, San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, United States
| | - Ghazaleh Afsahi
- Department of Biotechnology Research, BioSapien, San Diego, CA, United States
| | - Jiyo S. Athertya
- Department of Radiology, University of California San Diego, San Diego, CA, United States
| | - Hyungseok Jang
- Department of Radiology, University of California San Diego, San Diego, CA, United States
| | - Ya-Jun Ma
- Department of Radiology, University of California San Diego, San Diego, CA, United States
- *Correspondence: Ya-Jun Ma,
| |
Collapse
|
12
|
Jerban S, Oei EHG, Ding J. Editorial: Cartilage assessment using quantitative MRI. Front Endocrinol (Lausanne) 2022; 13:1092354. [PMID: 36523591 PMCID: PMC9745309 DOI: 10.3389/fendo.2022.1092354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 11/09/2022] [Indexed: 11/30/2022] Open
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, San Diego, CA, United States
- *Correspondence: Saeed Jerban,
| | - Edwin H. G. Oei
- Department of Radiology & Nuclear Medicine, Erasmus Medical Center (MC), University Medical Center, Rotterdam, Netherlands
| | - Jianping Ding
- Department of Radiology, Affiliated Hospital of Hangzhou Normal University, Hangzhou, China
| |
Collapse
|
13
|
Afsahi AM, Ma Y, Jang H, Jerban S, Chung CB, Chang EY, Du J. Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging. J Magn Reson Imaging 2021; 55:1597-1612. [PMID: 34962335 DOI: 10.1002/jmri.28032] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 12/06/2021] [Accepted: 12/07/2021] [Indexed: 12/14/2022] Open
Abstract
This review article summarizes recent technical developments in ultrashort echo time (UTE) magnetic resonance imaging of musculoskeletal (MSK) tissues with short-T2 relaxation times. A series of contrast mechanisms are discussed for high-contrast morphological imaging of short-T2 MSK tissues including the osteochondral junction, menisci, ligaments, tendons, and bone. Quantitative UTE mapping of T1, T2*, T1ρ, adiabatic T1ρ, magnetization transfer ratio, MT modeling of macromolecular proton fraction, quantitative susceptibility mapping, and water content is also introduced. Met and unmet needs in MSK imaging are discussed. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 3.
Collapse
Affiliation(s)
- Amir Masoud Afsahi
- Department of Radiology, University of California, San Diego, California, USA
| | - Yajun Ma
- Department of Radiology, University of California, San Diego, California, USA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, California, USA
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, California, USA
| | - Christine B Chung
- Department of Radiology, University of California, San Diego, California, USA.,Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California, USA
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, California, USA.,Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, California, USA.,Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California, USA
| |
Collapse
|
14
|
Lombardi AF, Wei Z, Wong J, Carl M, Lee RR, Wallace M, Masuda K, Chang EY, Du J, Ma YJ. High contrast cartilaginous endplate imaging using a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence. NMR IN BIOMEDICINE 2021; 34:e4579. [PMID: 34219287 PMCID: PMC8944187 DOI: 10.1002/nbm.4579] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 06/10/2021] [Accepted: 06/12/2021] [Indexed: 05/08/2023]
Abstract
Ultrashort echo time (UTE) sequences can image tissues with transverse T 2 /T 2 * relaxations too short to be efficiently observed on routine clinical MRI sequences, such as the vertebral body cartilaginous endplate (CEP). Here, we describe a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence to highlight the CEP of vertebral bodies in comparison to the intervertebral disc (IVD) and bone marrow fat (BF) at 3 T. The IR-FS-UTE sequence used a 3D UTE sequence combined with an adiabatic IR preparation pulse centered in the middle of the water and fat peaks, while a fat saturation module was used to suppress the signal from fat. A slab-selective half pulse was used for signal excitation, and a 3D center-out cones trajectory was used for more efficient data sampling. The 3D IR-FS-UTE sequence was applied to an ex vivo human spine sample, as well as the spines of six healthy volunteers and of three patients with back pain. Bright continuous lines representing signal from CEP were found in healthy IVDs. The measured contrast-to-noise ratio was 18.5 ± 4.9 between the CEP and BF, and 20.3 ± 4.15 between the CEP and IVD for the six volunteers. Abnormal IVDs showed CEP discontinuity or irregularity in the sample and patient studies. In conclusion, the proposed 3D IR-FS-UTE sequence is feasible for imaging the vertebral body's CEP in vivo with high contrast.
Collapse
Affiliation(s)
- Alecio F. Lombardi
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Zhao Wei
- Department of Radiology, University of California San Diego, CA, United States
| | - Jonathan Wong
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | | | - Roland R. Lee
- Department of Radiology, University of California San Diego, CA, United States
| | - Mark Wallace
- Department of Anesthesiology, University of California San Diego, CA, United States
| | - Koichi Masuda
- Department of Orthopedic Surgery, University of California San Diego, CA, United States
| | - Eric Y. Chang
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Jiang Du
- Department of Radiology, University of California San Diego, CA, United States
| | - Ya-Jun Ma
- Department of Radiology, University of California San Diego, CA, United States
| |
Collapse
|
15
|
Lombardi AF, Jang H, Wei Z, Jerban S, Wallace M, Masuda K, Ma YJ. High-contrast osteochondral junction imaging using a 3D dual adiabatic inversion recovery-prepared ultrashort echo time cones sequence. NMR IN BIOMEDICINE 2021; 34:e4559. [PMID: 34021649 PMCID: PMC8254801 DOI: 10.1002/nbm.4559] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 04/14/2021] [Accepted: 05/06/2021] [Indexed: 05/08/2023]
Abstract
While conventional MRI sequences cannot visualize tissues from the osteochondral junction (OCJ) due to these tissues' short transverse T2 /T2 * relaxations, ultrashort echo time (UTE) sequences can overcome this limitation. A 2D UTE sequence with a dual adiabatic inversion recovery preparation (DIR-UTE) for selective imaging of short T2 tissues with high contrast has previously been developed, but high sensitivity to eddy currents and aliased out-of-slice excitation make it difficult to image the thin layer of the OCJ in vivo. Here, we combine the DIR scheme with a 3D UTE cones sequence for volumetric imaging of OCJ tissues in vivo, aiming to generate higher OCJ contrast compared with a recently developed single IR-prepared UTE sequence with a fat saturation module (IR-FS-UTE). All sequences were implemented on a 3-T clinical scanner. The DIR-UTE cones sequence combined a 3D UTE cones sequence with two narrow-band adiabatic IR preparation pulses centered on water and fat spectrum frequencies, respectively. The 3D DIR-UTE cones sequence was first applied to a phantom, then to the knees of four healthy volunteers and four patients diagnosed with osteoarthritis and compared with the IR-FS-UTE sequence. In both phantom and volunteer studies, the proposed DIR-UTE cones sequence showed much higher contrast for OCJ imaging than the IR-FS-UTE sequence did. The 3D DIR-UTE cones sequence showed a significantly higher contrast-to-noise ratio between the OCJ and subchondral bone fat (mean, standard deviation [SD]: 25.7 ± 2.3) and between the OCJ and superficial layers of cartilage (mean, SD: 22.2 ± 3.5) compared with the IR-FS-UTE sequence (mean, SD: 10.8 ± 2.5 and 16.3 ± 2.6, respectively). The 3D DIR-UTE cones sequence is feasible for imaging of the OCJ region of the knee in vivo and produces both high resolution and high contrast.
Collapse
Affiliation(s)
- Alecio F. Lombardi
- Department of Radiology, University of California, San Diego, CA
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, CA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, CA
| | - Zhao Wei
- Department of Radiology, University of California, San Diego, CA
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, CA
| | - Mark Wallace
- Department of Anesthesiology, University of California San Diego, La Jolla, CA
| | - Koichi Masuda
- Department of Orthopedic Surgery, University of California San Diego, La Jolla, CA
| | - Ya-Jun Ma
- Department of Radiology, University of California, San Diego, CA
| |
Collapse
|
16
|
Automated cartilage segmentation and quantification using 3D ultrashort echo time (UTE) cones MR imaging with deep convolutional neural networks. Eur Radiol 2021; 31:7653-7663. [PMID: 33783571 DOI: 10.1007/s00330-021-07853-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 12/18/2020] [Accepted: 01/15/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To develop a fully automated full-thickness cartilage segmentation and mapping of T1, T1ρ, and T2*, as well as macromolecular fraction (MMF) by combining a series of quantitative 3D ultrashort echo time (UTE) cones MR imaging with a transfer learning-based U-Net convolutional neural networks (CNN) model. METHODS Sixty-five participants (20 normal, 29 doubtful-minimal osteoarthritis (OA), and 16 moderate-severe OA) were scanned using 3D UTE cones T1 (Cones-T1), adiabatic T1ρ (Cones-AdiabT1ρ), T2* (Cones-T2*), and magnetization transfer (Cones-MT) sequences at 3 T. Manual segmentation was performed by two experienced radiologists, and automatic segmentation was completed using the proposed U-Net CNN model. The accuracy of cartilage segmentation was evaluated using the Dice score and volumetric overlap error (VOE). Pearson correlation coefficient and intraclass correlation coefficient (ICC) were calculated to evaluate the consistency of quantitative MR parameters extracted from automatic and manual segmentations. UTE biomarkers were compared among different subject groups using one-way ANOVA. RESULTS The U-Net CNN model provided reliable cartilage segmentation with a mean Dice score of 0.82 and a mean VOE of 29.86%. The consistency of Cones-T1, Cones-AdiabT1ρ, Cones-T2*, and MMF calculated using automatic and manual segmentations ranged from 0.91 to 0.99 for Pearson correlation coefficients, and from 0.91 to 0.96 for ICCs, respectively. Significant increases in Cones-T1, Cones-AdiabT1ρ, and Cones-T2* (p < 0.05) and a decrease in MMF (p < 0.001) were observed in doubtful-minimal OA and/or moderate-severe OA over normal controls. CONCLUSION Quantitative 3D UTE cones MR imaging combined with the proposed U-Net CNN model allows a fully automated comprehensive assessment of articular cartilage. KEY POINTS • 3D UTE cones imaging combined with U-Net CNN model was able to provide fully automated cartilage segmentation. • UTE parameters obtained from automatic segmentation were able to reliably provide a quantitative assessment of cartilage.
Collapse
|
17
|
Jang H, Ma Y, Carl M, Jerban S, Chang EY, Du J. Ultrashort echo time Cones double echo steady state (UTE-Cones-DESS) for rapid morphological imaging of short T 2 tissues. Magn Reson Med 2021; 86:881-892. [PMID: 33755258 DOI: 10.1002/mrm.28769] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 02/17/2021] [Accepted: 02/18/2021] [Indexed: 12/12/2022]
Abstract
PURPOSE In this study, we aimed to develop a new technique, ultrashort echo time Cones double echo steady state (UTE-Cones-DESS), for highly efficient morphological imaging of musculoskeletal tissues with short T2 s. We also proposed a novel, single-point Dixon (spDixon)-based approach for fat suppression. METHODS The UTE-Cones-DESS sequence was implemented on a 3T MR system. It uses a short radiofrequency (RF) pulse followed by a pair of balanced spiral-out and spiral-in readout gradients separated by an unbalanced spoiling gradient in-between. The readout gradients are applied immediately before or after the RF pulses to achieve a UTE image (S+ ) and a spin/stimulated echo image (S- ). Weighted echo subtraction between S+ and S- was performed to achieve high contrast specific to short T2 tissues, and spDixon was applied to suppress fat by using the intrinsic complex signal of S+ and S- . Six healthy volunteers and five patients with osteoarthritis were recruited for whole-knee imaging. Additionally, two healthy volunteers were recruited for lower leg imaging. RESULTS The UTE-Cones-DESS sequence allows fast volumetric imaging of musculoskeletal tissues with excellent image contrast for the osteochondral junction, tendons, menisci, and ligaments in the knee joint as well as cortical bone and aponeurosis in the lower leg within 5 min. spDixon yields efficient fat suppression in both S+ and S- images without requiring any additional acquisitions or preparation pulses. CONCLUSION The rapid UTE-Cones-DESS sequence can be used for high contrast morphological imaging of short T2 tissues, providing a new tool to assess their association with musculoskeletal disorders.
Collapse
Affiliation(s)
- Hyungseok Jang
- Department of Radiology, University of California, San Diego, San Diego, CA, USA
| | - Yajun Ma
- Department of Radiology, University of California, San Diego, San Diego, CA, USA
| | | | - Saeed Jerban
- Department of Radiology, University of California, San Diego, San Diego, CA, USA
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, San Diego, CA, USA.,Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, San Diego, CA, USA
| |
Collapse
|
18
|
Jang H, Ma Y, Carl M, Lombardi AF, Chang EY, Du J. Feasibility of an Inversion Recovery-Prepared Fat-Saturated Zero Echo Time Sequence for High Contrast Imaging of the Osteochondral Junction. Front Endocrinol (Lausanne) 2021; 12:777080. [PMID: 35002964 PMCID: PMC8739813 DOI: 10.3389/fendo.2021.777080] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 12/02/2021] [Indexed: 12/11/2022] Open
Abstract
PURPOSE The osteochondral junction (OCJ) region-commonly defined to include the deep radial uncalcified cartilage, tidemark, calcified cartilage, and subchondral bone plate-functions to absorb mechanical stress and is commonly associated with the pathogenesis of osteoarthritis. However, magnetic resonance imaging of the OCJ region is difficult due to the tissues' short transverse relaxation times (i.e., short T2 or T2*), which result in little or no signal with conventional MRI. The goal of this study is to develop a 3D adiabatic inversion recovery prepared fat saturated zero echo time (IR-FS-ZTE) sequence for high-contrast imaging of the OCJ. METHOD An IR-FS-ZTE MR sequence was developed to image the OCJ on a clinical 3T MRI scanner. The IR-FS-ZTE sequence employed an adiabatic inversion pulse followed by a fat saturation pulse that suppressed signals from the articular cartilage and fat. At an inversion time (TI) that was matched to the nulling point of the articular cartilage, continuous ZTE imaging was performed with a smoothly rotating readout gradient, which enabled time-efficient encoding of the OCJ region's short T2 signal with a minimal echo time (TE) of 12 μs. An ex vivo experiment with six cadaveric knee joints, and an in vivo experiment with six healthy volunteers and three patients with OA were performed to evaluate the feasibility of the proposed approach for high contrast imaging of the OCJ. Contrast-to-noise ratios (CNRs) between the OCJ and its neighboring femoral and tibial cartilage were measured. RESULTS In the ex vivo experiment, IR-FS-ZTE produced improved imaging of the OCJ region over the clinical sequences, and significantly improved the contrast compared to FS-ZTE without IR preparation (p = 0.0022 for tibial cartilage and p = 0.0019 for femoral cartilage with t-test). We also demonstrated the feasibility of high contrast imaging of the OCJ region in vivo using the proposed IR-FS-ZTE sequence, thereby providing more direct information on lesions in the OCJ. Clinical MRI did not detect signal from OCJ due to the long TE (>20 ms). CONCLUSION IR-FS-ZTE allows direct imaging of the OCJ region of the human knee and may help in elucidating the role of the OCJ in cartilage degeneration.
Collapse
Affiliation(s)
- Hyungseok Jang
- Department of Radiology, University of California, San Diego, CA, United States
| | - Yajun Ma
- Department of Radiology, University of California, San Diego, CA, United States
| | | | - Alecio F. Lombardi
- Department of Radiology, University of California, San Diego, CA, United States
| | - Eric Y. Chang
- Department of Radiology, University of California, San Diego, CA, United States
- Radiology Service, VA San Diego Healthcare System, San Diego, CA, United States
| | - Jiang Du
- Department of Radiology, University of California, San Diego, CA, United States
- *Correspondence: Jiang Du,
| |
Collapse
|
19
|
Jang H, McMillan AB, Ma Y, Jerban S, Chang EY, Du J, Kijowski R. Rapid single scan ramped hybrid-encoding for bicomponent T2* mapping in a human knee joint: A feasibility study. NMR IN BIOMEDICINE 2020; 33:e4391. [PMID: 32761692 PMCID: PMC7584401 DOI: 10.1002/nbm.4391] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 06/20/2020] [Accepted: 07/21/2020] [Indexed: 05/03/2023]
Abstract
The purpose of this study is to determine the feasibility of using a single scan ramped hybrid-encoding (RHE) method for rapid bicomponent T2* analysis of the human knee joint. The proposed method utilizes RHE to acquire ultrashort echo time (UTE) and subsequent gradient echo images at 16 different echo times ranging between 40 μs and 30 ms in a single scan. In the proposed RHE technique, UTE imaging was followed by acquisition of 14 gradient recalled echo images, where an additional UTE image was obtained within the first readout by oversampling single point imaging (SPI) encoding. The single scan RHE method with a 9-minute scan time was performed on human cadaveric knee joints from six donors and in vivo knee joints from four healthy volunteers at 3 T. A bicomponent signal model was used to characterize the short T2* and long T2* water components. Mean bicomponent T2* parameters for patellar tendon, anterior cruciate ligament (ACL), posterior cruciate ligament (PCL) and meniscus were calculated. In the experimental results, the RHE technique provided bicomponent T2* parameter estimations of tendon, ACL, PCL and meniscus, which were similar to previously reported values in the literature. In conclusion, the proposed single scan RHE technique provides rapid bicomponent T2* analysis of the human knee joint with a total scan time of less than 9 minutes.
Collapse
Affiliation(s)
- Hyungseok Jang
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA
- Corresponding Author: Hyungseok Jang, Ph.D., University of California, San Diego, Department of Radiology, 200 West Arbor Drive, San Diego, CA 92103-8226, Phone (858) 246-2225,
| | - Alan B McMillan
- Department of Radiology, University of Wisconsin Madison, Madison, WI 53705, USA
| | - Yajun Ma
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA
| | - Saeed Jerban
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA
| | - Eric Y Chang
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA
- Radiology Service, VA San Diego Healthcare System, San Diego, CA 92037, USA
| | - Jiang Du
- Department of Radiology, University of California San Diego, San Diego, CA 92103, USA
| | - Richard Kijowski
- Department of Radiology, University of Wisconsin Madison, Madison, WI 53705, USA
| |
Collapse
|
20
|
Cai Z, Wei Z, Wu M, Jerban S, Jang H, Li S, Yuan X, Ma YJ. Knee osteochondral junction imaging using a fast 3D T 1-weighted ultrashort echo time cones sequence at 3T. Magn Reson Imaging 2020; 73:76-83. [PMID: 32828984 DOI: 10.1016/j.mri.2020.08.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 07/24/2020] [Accepted: 08/14/2020] [Indexed: 12/14/2022]
Abstract
The osteochondral junction (OCJ) of the knee joint is comprised of multiple tissue components, including a portion of the deep layer cartilage, calcified cartilage, and subchondral bone. The OCJ is of increasing radiological interest as it may be relevant in the early pathogenesis of osteoarthritis (OA). Due to its short transverse relaxation, the OCJ is invisible to clinical MR sequences. The purpose of this study was to develop a fast 3D T1-weighted ultrashort echo time cones sequence with fat saturation (FS-UTE-Cones) for high resolution and high contrast imaging of the OCJ on a clinical 3T scanner. First, numerical simulations were performed to investigate how the flip angle affected the signal intensities and contrasts of both short and long T1 tissues. The results from these simulations demonstrated that higher short T1 contrast could be achieved with higher flip angle. Next, T1 relaxation was measured for the different layers of a human patellar cartilage sample, and the results showed that the deepest layer had a significantly shorter T1 value than other layers. Finally, a healthy knee joint was scanned with different flip angles and the OCJ was highlighted in the T1-weighted FS-UTE-Cones sequence using a flip angle greater than 20°. The clinical T2-weighted and proton density-weighted FSE sequences were also included for comparison, revealing a dark OCJ region. Representative T1-weighted FS-UTE-Cones images of the whole knee of a healthy volunteer showed high signal intensity bands in the OCJ regions of the patella, femur, and tibia. On the other hand, T1-weighted FS-UTE-Cones imaging of the knee joints of OA patients revealed regions with reduction or loss of these high signal intensity bands in the OCJ regions, indicating abnormal OCJ tissue composition. The proposed 3D T1-weighted FS-UTE-Cones sequence with a 3-min scan time may be very useful for demonstrating the involvement of the OCJ regions in early OA.
Collapse
Affiliation(s)
- Zhenyu Cai
- Department of Radiology, Fuwai Hospital Chinese Academy of Medical Sciences, Guangdong, China; Department of Radiology, University of California, San Diego, CA, USA
| | - Zhao Wei
- Department of Radiology, University of California, San Diego, CA, USA
| | - Mei Wu
- Department of Radiology, University of California, San Diego, CA, USA
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, CA, USA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, CA, USA
| | - Shaolin Li
- Department of Radiology, The Fifth Affiliated Hospital of Sun Yat-Sen University, Guangdong, China
| | - Xuchun Yuan
- Department of Radiology, Fuwai Hospital Chinese Academy of Medical Sciences, Guangdong, China
| | - Ya-Jun Ma
- Department of Radiology, University of California, San Diego, CA, USA.
| |
Collapse
|
21
|
Jerban S, Chang EY, Du J. Magnetic resonance imaging (MRI) studies of knee joint under mechanical loading: Review. Magn Reson Imaging 2019; 65:27-36. [PMID: 31670237 DOI: 10.1016/j.mri.2019.09.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 08/17/2019] [Accepted: 09/15/2019] [Indexed: 02/07/2023]
Abstract
Osteoarthritis (OA) is a very common disease that affects the human knee joint, particularly the articular cartilage and meniscus components which are regularly under compressive mechanical loads. Early-stage OA diagnosis is essential as it allows for timely intervention. The primary non-invasive approaches currently available for OA diagnosis include magnetic resonance imaging (MRI), which provides excellent soft tissue contrast at high spatial resolution. MRI-based knee investigation is usually performed on joints at rest or in a non-weight-bearing condition that does not mimic the actual physiological condition of the joint. This discrepancy may lead to missed detections of early-stage OA or of minor lesions. The mechanical properties of degenerated musculoskeletal (MSK) tissues may vary markedly before any significant morphological or structural changes detectable by MRI. Recognizing distinct deformation characteristics of these tissues under known mechanical loads may reveal crucial joint lesions or mechanical malfunctions which result from early-stage OA. This review article summarizes the large number of MRI-based investigations on knee joints under mechanical loading which have been reported in the literature including the corresponding MRI measures, the MRI-compatible devices employed, and potential challenges due to the limitations of clinical MRI sequences.
Collapse
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, CA, USA.
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, CA, USA; Radiology Service, VA San Diego Healthcare System, San Diego, CA, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, CA, USA
| |
Collapse
|