1
|
Brunet TA, Ayciriex S, Arquier D, Lemoine J, Randon J, Salvador A. Scout triggered multiple reaction monitoring mass spectrometry for the rapid transfer of large multiplexed targeted methods in metabolomics. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1228:123849. [PMID: 37634392 DOI: 10.1016/j.jchromb.2023.123849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 07/20/2023] [Accepted: 08/11/2023] [Indexed: 08/29/2023]
Abstract
The field of metabolomics based on mass spectrometry has grown considerably in recent years due to the need to detect and, above all, quantify a very large number of metabolites, simultaneously. Up to now, targeted multiplexed analysis on complex samples by Liquid Chromatography coupled with tandem Mass Spectrometry (LC-MS/MS) has relied almost exclusively on compound detection based on absolute retention times, as in the Scheduled-MRM (sMRM) approach. Those methods turn out to be poorly transferable from one instrument to another and result in a time-consuming and tedious method development involving a significant number of critical parameters that need specific re-optimisation. To address this challenge, we introduce a novel acquisition mode called scout-triggered MRM (stMRM). In stMRM, a marker transition is used to trigger MS analysis for a group of dependent target analytes. These marker transitions are strategically distributed throughout the chromatographic run, and the dependent analytes are associated based on their retention times. The result is a targeted assay that remains robust even in the presence of retention time shifts. A 3 to 5-fold increase in the number of detected transitions associated to plasma metabolites was obtained when transferring from a direct application of a published sMRM to a stMRM method. This significant improvement highlights the universal applicability of the stMRM method, as it can be implemented on any LC system without the need for extensive method development. We subsequently illustrate the robustness of stMRM in modified chromatographic elution conditions. Despite a large change in metabolite's selectivity, the multiplexed assay successfully recovered 70% of the monitored transitions when consequently modifying the gradient method. These findings demonstrate the versatility and adaptability of stMRM, opening new avenues for the development of highly multiplexed LC-MS/MS methods in metabolomics. These methods are characterized by their analytical transparency and straightforward implementation using existing literature data.
Collapse
Affiliation(s)
- Thomas Alexandre Brunet
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France
| | - Sophie Ayciriex
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France
| | - Delphine Arquier
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France
| | - Jérôme Lemoine
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France
| | - Jérôme Randon
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France
| | - Arnaud Salvador
- Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France.
| |
Collapse
|
2
|
van Bentum M, Selbach M. An Introduction to Advanced Targeted Acquisition Methods. Mol Cell Proteomics 2021; 20:100165. [PMID: 34673283 PMCID: PMC8600983 DOI: 10.1016/j.mcpro.2021.100165] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 10/11/2021] [Accepted: 10/13/2021] [Indexed: 01/13/2023] Open
Abstract
Targeted proteomics via selected reaction monitoring (SRM) or parallel reaction monitoring (PRM) enables fast and sensitive detection of a preselected set of target peptides. However, the number of peptides that can be monitored in conventional targeting methods is usually rather small. Recently, a series of methods has been described that employ intelligent acquisition strategies to increase the efficiency of mass spectrometers to detect target peptides. These methods are based on one of two strategies. First, retention time adjustment-based methods enable intelligent scheduling of target peptide retention times. These include Picky, iRT, as well as spike-in free real-time adjustment methods such as MaxQuant.Live. Second, in spike-in triggered acquisition methods such as SureQuant, Pseudo-PRM, TOMAHAQ, and Scout-MRM, targeted scans are initiated by abundant labeled synthetic peptides added to samples before the run. Both strategies enable the mass spectrometer to better focus data acquisition time on target peptides. This either enables more sensitive detection or a higher number of targets per run. Here, we provide an overview of available advanced targeting methods and highlight their intrinsic strengths and weaknesses and compatibility with specific experimental setups. Our goal is to provide a basic introduction to advanced targeting methods for people starting to work in this field. Advanced acquisition methods improve focus of mass spectrometers on target peptides. This review discusses existing methods based on two strategies. Retention time adjustment-based methods enable intelligent scheduling of peptide RTs. In spike-in triggered acquisition methods targeted scans are initiated by spike-ins.
Collapse
Affiliation(s)
- Mirjam van Bentum
- Proteome Dynamics, Max Delbrück Center for Molecular Medicine, Berlin, Germany; Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Matthias Selbach
- Proteome Dynamics, Max Delbrück Center for Molecular Medicine, Berlin, Germany; Charité-Universitätsmedizin Berlin, Berlin, Germany.
| |
Collapse
|
3
|
Trauchessec M, Hesse AM, Kraut A, Berard Y, Herment L, Fortin T, Bruley C, Ferro M, Manin C. An innovative standard for LC-MS-based HCP profiling and accurate quantity assessment: Application to batch consistency in viral vaccine samples. Proteomics 2021; 21:e2000152. [PMID: 33459490 DOI: 10.1002/pmic.202000152] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 10/10/2020] [Accepted: 12/18/2020] [Indexed: 11/05/2022]
Abstract
Biotherapeutics, molecules produced from biological systems, require rigorous purification steps to remove impurities including host cell proteins (HCPs). Regulatory guidelines require manufacturers to monitor process-related impurities along the purification workflow. Mass spectrometry (MS) has recently been considered as a complementary method to the well-established ELISA for HCPs quantification, since it has the advantage of unambiguously identifying individual HCP. In this study, we developed an innovative standard dedicated to MS-based HCP profiling analysis in order to monitor the consistency of viral vaccine intermediate purification samples. This standard, termed the HCP-PROFILER standard, is composed of a water-soluble bead (READYBEADS technology) which, after being added into the sample, releases unlabeled peptides in controlled amounts. The standard meets three desired criteria: (1) it is composed of multiple peptides, at different concentration levels, allowing construction of a calibration curve covering the dynamic range of HCPs present in the target sample, ensuring quantification accuracy; (2) it demonstrates high batch-to-batch reproducibility, ensuring quantification robustness and consistency over time; and (3) it is easy to use and avoids user-induced analytical biases. In this study, we present the use of the HCP-PROFILER standard for vaccine batches comparison and downstream process performance studies.
Collapse
Affiliation(s)
- Mathieu Trauchessec
- ANAQUANT, Villeurbanne, France.,CEA, 17 av. des Martyrs, Grenoble, 38000, France
| | | | | | | | | | | | | | - Myriam Ferro
- CEA, 17 av. des Martyrs, Grenoble, 38000, France
| | | |
Collapse
|
4
|
High-multiplexed monitoring of protein biomarkers in the sentinel Gammarus fossarum by targeted scout-MRM assay, a new vision for ecotoxicoproteomics. J Proteomics 2020; 226:103901. [PMID: 32668291 DOI: 10.1016/j.jprot.2020.103901] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 06/02/2020] [Accepted: 07/08/2020] [Indexed: 11/23/2022]
Abstract
Ecotoxicoproteomics employs mass spectrometry-based approaches centered on proteins of sentinel organisms to assess for instance, chemical toxicity in fresh water. In this study, we combined proteogenomics experiments and a novel targeted proteomics approach free from retention time scheduling called Scout-MRM. This methodology will enable the measurement of simultaneously changes in the relative abundance of multiple proteins involved in key physiological processes and potentially impacted by contaminants in the freshwater sentinel Gammarus fossarum. The development and validation of the assay were performed to target 157 protein biomarkers of this non-model organism. We carefully chose and validated the transitions to monitor using conventional parameters (linearity, repeatability, LOD, LOQ). Finally, the potential of the methodology is illustrated by measuring 277-peptide-plex assay (831 transitions) in sentinel animals exposed in natura to different agricultural sites potentially exposed to pesticide contamination. Multivariate data analyses highlighted the modulation of several key proteins involved in feeding and molting. This multiplex-targeted proteomics assay paves the way for the discovery and the use of a large panel of novel protein biomarkers in emergent ecotoxicological models for environmental monitoring in the future. BIOLOGICAL SIGNIFICANCE: The study contributed to the development of Scout-MRM for the high-throughput quantitation of a large panel of proteins in the Gammarus fossarum freshwater sentinel. Increasing the number of markers in ecotoxicoproteomics is of most interest to assess the impact of pollutants in freshwater organisms. The development and validation of the assay enabled the monitoring of a large panel of reporter peptides of exposed gammarids. To illustrate the applicability of the methodology, animals from different agricultural sites were analysed. The application of the assay highlighted the modulation of some biomarker proteins involved in key physiological pathways, such as molting, feeding and general stress response. Increasing multiplexing capabilities and field test will provide the development of diagnostic protein biomarkers for emergent ecotoxicological models in future environmental biomonitoring programs.
Collapse
|
5
|
Remes PM, Yip P, MacCoss MJ. Highly Multiplex Targeted Proteomics Enabled by Real-Time Chromatographic Alignment. Anal Chem 2020; 92:11809-11817. [PMID: 32867497 DOI: 10.1021/acs.analchem.0c02075] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Targeted mass spectrometry methods produce high-quality quantitative data in terms of limits of detection and dynamic range, at the cost of a substantial compromise in throughput compared to methods such as data independent and data dependent acquisition. The logistical and experimental issues inherent to maintaining assays of even several hundred targets are significant. Prominent among these issues is the drift in analyte retention time as liquid chromatography (LC) columns wear, forcing targeted scheduling windows to be much larger than LC peak widths. If these problems could be solved, proteomics assays would be capable of targeting thousands of peptides in an hour-long experiment, enabling large cohort studies to be performed without sacrificing sensitivity and specificity. We describe a solution in the form of a new method for real-time chromatographic alignment and demonstrate its application to a 56 min LC-gradient HeLa digest assay with 1489 targets. The method is based on the periodic acquisition of untargeted survey scans in a reference experiment and alignment to those scans during subsequent experiments. We describe how the method enables narrower scheduled retention time windows to be used. The narrower scheduling windows enables more targets to be included in the assay or proportionally more time to be allocated to each target, improving the sensitivity. Finally, we point out how the procedure could be improved and how much additional target multiplexing could be gained in the future.
Collapse
Affiliation(s)
- Philip M Remes
- Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, California 95134, United States
| | - Ping Yip
- Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, California 95134, United States
| | - Michael J MacCoss
- Department of Genome Sciences, University of Washington, 3720 15th Street NE, Seattle, Washington 98195, United States
| |
Collapse
|
6
|
Salvador A, Carrière R, Ayciriex S, Margoum C, Leblanc Y, Lemoine J. Scout-multiple reaction monitoring: A liquid chromatography tandem mass spectrometry approach for multi-residue pesticide analysis without time scheduling. J Chromatogr A 2020; 1621:461046. [DOI: 10.1016/j.chroma.2020.461046] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 01/15/2020] [Accepted: 03/12/2020] [Indexed: 11/24/2022]
|