1
|
McCarney L, Lythgo N, Fazalbhoy A, Moreland A. Objective measures of stiffness and ratings of pain and stiffness in the gastrocnemii following delayed-onset muscle soreness. J Bodyw Mov Ther 2025; 41:187-193. [PMID: 39663086 DOI: 10.1016/j.jbmt.2024.11.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 11/01/2024] [Accepted: 11/16/2024] [Indexed: 12/13/2024]
Abstract
BACKGROUND Muscle stiffness is commonly associated with a sensation of tightness, pain and movement difficulty. It is unclear, however, whether changes in muscle stiffness can be objectively identified by myotonometry across time. This study investigated whether a myotonometer (MyotonPRO) can detect changes in muscle stiffness by delayed-onset muscle soreness (DOMS). METHODS Twenty-three healthy adults participated in this study. DOMS was achieved in the gastrocnemii by downhill-backwards walking on a motorised treadmill. Subjective ratings of gastrocnemii pain and stiffness were recorded using the numerical rating scale. The MyotonPRO was used to record and extract objective muscle stiffness data. Recordings were taken at baseline and over a three-week recovery period. Spearman's rho correlation analyses were conducted between objective measures and subjective ratings of pain and stiffness. Repeated measure ANOVA tests were conducted to investigate the effect of DOMS over time. FINDINGS No significant correlations were found between the objective measures and subjective ratings of pain (p = 0.22) or stiffness (p = 0.51). Myotonometry identified significant effects of DOMS on muscle stiffness (p < 0.001) over time. Significant effects of DOMS on subjective pain and stiffness rating data were found over time (p < 0.001). INTERPRETATIONS Although DOMS was found to affect objective measures of muscle stiffness, these changes were not associated with subjective ratings. Future studies could replicate this study using other myotonometry methods to further investigate muscle stiffness and involve a larger cohort. Other work should investigate muscle stiffness in clinical musculoskeletal conditions resulting from injury or chronic pain.
Collapse
Affiliation(s)
- Luke McCarney
- School of Health and Biomedical Sciences, RMIT University, Bundoora, VIC, 3083, Australia.
| | - Noel Lythgo
- School of Health and Biomedical Sciences, RMIT University, Bundoora, VIC, 3083, Australia
| | - Azharuddin Fazalbhoy
- School of Health and Biomedical Sciences, RMIT University, Bundoora, VIC, 3083, Australia
| | - Ashleigh Moreland
- School of Health and Biomedical Sciences, RMIT University, Bundoora, VIC, 3083, Australia
| |
Collapse
|
2
|
Ferran de la Cierva S, Terrasa D, Garaycochea O, Del Rio B, Urdin M, Fernandez S. MyotonPRO as a new valid tool for measuring cervical muscle tension. A reliability study. LOGOP PHONIATR VOCO 2024:1-8. [PMID: 39120117 DOI: 10.1080/14015439.2024.2388896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 07/17/2024] [Accepted: 07/31/2024] [Indexed: 08/10/2024]
Abstract
OBJECTIVE The main objective of this study is to test the reliability of a non-invasive objective method for the measurement of biomechanical parameters of cervicofacial muscle groups, with the purpose of diagnosis and evaluation of voice disorders' treatments, especially focused on muscle tension dysphonia. STUDY DESIGN Prospective study. METHODS The device used is a handheld myotonometer (MyotonPRO) that measures biomechanical and viscoelastic properties in superficial soft tissues frequency, stiffness, elasticity, relaxation time and creep. It is used in the field of medicine, sport and research. This pilot study includes 10 subjects, who have been measured in the masseter, sternocleidomastoid, orbicularis oris, semispinalis capitis, suprahyoid, infrahyoid and trapezius muscles on each side. Measurements were performed by 2 evaluators to assess inter-evaluator reliability. Subsequently, one of them repeated the measurements to assess intra-evaluator reliability. RESULTS The results revealed good to excellent inter-rater reliability for the masseter, sternocleidomastoid, trapezius and suprahyoid muscles, with lower ICCs for the stiffness and creep properties. Intra-rater reliability was good to excellent for the masseter, sternocleidomastoid, semispinalis capitis and suprahyoid muscles. The lowest ICCs were found in the stiffness and creep properties. CONCLUSION The use of a myotonometer to measure the mechanical properties of selected cervical and orofacial muscles is a reliable and reproducible method. Future research is needed to establish an association between the properties of these muscles and their role in voice disorders, as well as to determine whether this tool can aid diagnosis with quantifiable and objectifiable indicators, and for monitoring and treatment efficacy.
Collapse
Affiliation(s)
| | - David Terrasa
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Octavio Garaycochea
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Beatriz Del Rio
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Mikel Urdin
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Secundino Fernandez
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| |
Collapse
|
3
|
Lettner J, Królikowska A, Ramadanov N, Oleksy Ł, Hakam HT, Becker R, Prill R. Evaluating the Reliability of MyotonPro in Assessing Muscle Properties: A Systematic Review of Diagnostic Test Accuracy. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:851. [PMID: 38929468 PMCID: PMC11205912 DOI: 10.3390/medicina60060851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 05/17/2024] [Accepted: 05/20/2024] [Indexed: 06/28/2024]
Abstract
Background and Objectives: Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro device offers a non-invasive method to comprehensively assess muscle biomechanical properties. This systematic review evaluates the reliability of MyotonPro across various muscles for diagnostic purposes. Materials and Methods: Following PRISMA guidelines, a comprehensive literature search was conducted in Medline (PubMed), Ovid (Med), Epistemonikos, Embase, Cochrane Library, Clinical trials.gov, and the WHO International Clinical Trials platform. Studies assessing the reliability of MyotonPro across different muscles were included. A methodological quality assessment was performed using established tools, and reviewers independently conducted data extraction. Statistical analysis involved summarizing intra-rater and inter-rater reliability measures across muscles. Results: A total of 48 studies assessing 31 muscles were included in the systematic review. The intra-rater and inter-rater reliability were consistently high for parameters such as frequency and stiffness in muscles of the lower and upper extremities, as well as other muscle groups. Despite methodological heterogeneity and limited data on specific parameters, MyotonPro demonstrated promising reliability for diagnostic purposes across diverse patient populations. Conclusions: The findings suggest the potential of MyotonPro in clinical assessments for accurate diagnosis, treatment planning, and monitoring of muscle properties. Further research is needed to address limitations and enhance the applicability of MyotonPro in clinical practice. Reliable muscle assessments are crucial for optimizing treatment outcomes and improving patient care in various healthcare settings.
Collapse
Affiliation(s)
- Jonathan Lettner
- Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School, Hochstraße 29, 14770 Brandenburg an der Havel, Germany; (J.L.)
| | - Aleksandra Królikowska
- Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, Tytusa Chalubinskiego 3, 50-368 Wroclaw, Poland;
| | - Nikolai Ramadanov
- Faculty of Health Science, Brandenburg Medical School, 14770 Brandenburg an der Havel, Germany
| | - Łukasz Oleksy
- Department of Physiotherapy, Faculty of Health Sciences, Jagiellonian University Medical College, Michałowskiego 12, 31-126 Krakow, Poland
- Department of Orthopaedics, Traumatology and Hand Surgery, Faculty of Medicine, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw, Poland
| | - Hassan Tarek Hakam
- Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School, Hochstraße 29, 14770 Brandenburg an der Havel, Germany; (J.L.)
- Faculty of Health Science, Brandenburg Medical School, 14770 Brandenburg an der Havel, Germany
| | - Roland Becker
- Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School, Hochstraße 29, 14770 Brandenburg an der Havel, Germany; (J.L.)
- Faculty of Health Science, Brandenburg Medical School, 14770 Brandenburg an der Havel, Germany
| | - Robert Prill
- Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School, Hochstraße 29, 14770 Brandenburg an der Havel, Germany; (J.L.)
- Faculty of Health Science, Brandenburg Medical School, 14770 Brandenburg an der Havel, Germany
| |
Collapse
|
4
|
Çevik Saldıran T, Kara İ, Kutlutürk Yıkılmaz S. Quantification of the forearm muscles mechanical properties using Myotonometer: Intra- and Inter-Examiner reliability and its relation with hand grip strength. J Electromyogr Kinesiol 2022; 67:102718. [PMID: 36334405 DOI: 10.1016/j.jelekin.2022.102718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 10/10/2022] [Accepted: 10/19/2022] [Indexed: 12/13/2022] Open
Abstract
The primary objective of this study was to investigate the reliability of the myotonometer in the mechanical properties of the forearm muscles [m. extensor carpi radialis brevis (ECRB), and m. flexor carpi ulnaris (FCU)] in healthy individuals. The secondary objective was to investigate the relationship between the handgrip strength and mechanical properties of these forearm muscles. The mechanical properties (muscle tone, stiffness, and elasticity) of the ECRB and FCU were measured using the MyotonPRO device. Examiner 1 performed two sets of measurements with a time interval of 30 min to determine intra-examiner reliability. Examiner 2 performed measurements during the interval between the two sets of examiner 1. The intra- and inter-examiner reliabilities were excellent (ICC˃0.82) for muscle tone, stiffness, and elasticity of the FCU. Both intra- and inter-examiner reliability in the evaluation of ECRB muscle tone, elasticity, and stiffness was moderate to excellent (ICCs = 0.56-0.98). The muscle tone and stiffness properties of the FCU were positively correlated with the handgrip strength (p <.05). The study findings indicate that the MyotonPRO device is a reliable tool to quantify ECRB, and FCU muscles mechanical properties in healthy individuals.
Collapse
Affiliation(s)
- Tülay Çevik Saldıran
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Bitlis Eren University, Bitlis, Turkey.
| | - İlke Kara
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Bitlis Eren University, Bitlis, Turkey; Department of Physical Therapy and Rehabilitation, Institute of Health Sciences, Dokuz Eylul University, Izmir, Turkey
| | - Seval Kutlutürk Yıkılmaz
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Istanbul Medipol University, Istanbul, Turkey
| |
Collapse
|
5
|
Kurashina W, Iijima Y, Sasanuma H, Saito T, Takeshita K. Evaluation of muscle stiffness in adhesive capsulitis with Myoton PRO. JSES Int 2022; 7:25-29. [PMID: 36820433 PMCID: PMC9937826 DOI: 10.1016/j.jseint.2022.08.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background Adhesive capsulitis (AC) is characterized by pain and limited range of motion, caused by stiffness of the joint capsule and coracohumeral ligament. On the other hand, there have been few reports on muscle stiffness in AC. The purpose of this study was to assess muscle stiffness in patients of AC with a portable and noninvasive device, Myoton PRO. We hypothesized that muscle stiffness around shoulder joint increases in AC. Methods At first, we surveyed correlation between Myoton PRO and shear wave elastography with phantoms. Second, reproducibility and repeatability of healthy volunteers with Myoton PRO were evaluated. Finally, muscle stiffness was measured in 40 patients who were diagnosed with AC. Muscle stiffness was quantitatively measured with Myoton PRO. We compared the stiffness of the anterior deltoid (AD), pectoralis major, and latissimus dorsi (LD) in AC patients on both the affected and nonaffected sides. Results Correlation coefficient in shear wave elastography and Myoton PRO was 0.99(P = .001). Reliability of intraoperator and interoperator with Myoton PRO was 0.9 or higher. Muscle stiffness values (N/m) of the AD, pectoralis major, and LD were 355 ± 61, 252 ± 54, 207 ± 51 in the affected sides and 328 ± 50, 252 ± 41, 186 ± 37 in the nonaffected sides, and the differences were significant in the AD and LD (P = .005, P = .002, respectively). Conclusions We used Myoton PRO to evaluate muscle stiffness in AC. The AD and LD muscles of AC patients were significantly stiffer on the affected side compared to the nonaffected side.
Collapse
Affiliation(s)
- Wataru Kurashina
- Department of Rehabilitation, Tochigi Medical Center Shimotsuga, Ohira, Tochigi, Japan,Graduate School of Medicine, Jichi Medical University, Tochigi, Japan
| | - Yuki Iijima
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan,Corresponding author: Yuki Iijima, MD, Department of Orthopaedic Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 3292740822, Japan.
| | - Hideyuki Sasanuma
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan
| | - Tomohiro Saito
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan
| | - Katsushi Takeshita
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan
| |
Collapse
|
6
|
Koch V, Wilke J. Reliability of a New Indentometer Device for Measuring Myofascial Tissue Stiffness. J Clin Med 2022; 11:jcm11175194. [PMID: 36079124 PMCID: PMC9457058 DOI: 10.3390/jcm11175194] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 08/22/2022] [Accepted: 08/30/2022] [Indexed: 11/29/2022] Open
Abstract
Changes in tissue stiffness are associated with pathological conditions such as myofascial pain and increased risk of muscle injury. Furthermore, they have been shown to modify performance indicators such as running economy or jump height. Indentometry is an affordable way to assess tissue stiffness. However, to date, there is a paucity of studies examining the measurement properties of available devices. With this trial, we aimed to evaluate the reliability of the “IndentoPro”. Two investigators repeatedly measured the stiffness of the lateral head of the gastrocnemius muscle in healthy participants (N = 35), using 5 and 10 mm indentation depths. Intraclass Correlation Coefficients (ICC) revealed moderate inter-rater reliability (5 mm: ICC3,1 0.74, 95%CI = 0.54 to 0.86, p < 0.001; 10 mm: ICC3,1 0.59, 95%CI = 0.27 to 0.78, p < 0.001) and good intra-rater reliability (5 mm: ICC3,1 0.84, 95%CI = 0.71 to 0.92, p < 0.001; 10 mm: ICC3,1 0.83, 95%CI = 0.69 to 0.91, p < 0.001). No correlations between age, height, weight, BMI, skinfold thickness and myofascial tissue stiffness were observed (p > 0.5). In conclusion, the IndentoPro is reliable in assessing calf tissue stiffness, but the predictors of stiffness remain unclear.
Collapse
Affiliation(s)
- Virginija Koch
- Diploma Hochschule, 37242 Bad Sooden-Allendorf, Germany
- Correspondence:
| | - Jan Wilke
- Department of Movement Sciences, University of Klagenfurt, 9020 Klagenfurt am Wörthersee, Austria
- Institute of Occupational, Social and Environmental Medicine, Goethe University Frankfurt, 60590 Frankfurt am Main, Germany
| |
Collapse
|
7
|
Saldiran TÇ, Yazgan P, Akgöl AC, Mutluay FK. Radial shock-wave therapy for frozen shoulder patients with type 2 diabetes mellitus: a pilot trial comparing two different energy levels. Eur J Phys Rehabil Med 2022; 58:412-422. [PMID: 35191654 PMCID: PMC9980541 DOI: 10.23736/s1973-9087.22.07087-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Extracorporeal shock-wave therapy (ESWT) is highly recommended for the management of orthopedic shoulder pathologies. Yet, the clinical relevance of the dose difference effect of radial ESWT approaches in the management of frozen shoulder patients with type 2 diabetes mellitus remains uncertain. AIM The aim was to examine the short-term effects of medium-and high-energy levels of radial ESWT (rESWT) in the treatment of frozen shoulder patients with type 2 diabetes mellitus. DESIGN Prospective clinical pilot study. SETTING This study was conducted in an outpatient clinic. POPULATION Thirty-nine patients who had frozen shoulder untreated for at least 3 months, diagnosed with type 2 diabetes mellitus for ≥3 years were included. METHODS The patients were randomly allocated to receive either high-energy rESWT (hrESWT), or medium-energy rESWT (mrESWT) or placebo at 8 Hz twice a week for six weeks. The primary outcome measure was pain, evaluated by the Visual Analog Scale (VAS) Score. Secondary outcome measures were function evaluated by the Shoulder Pain and Disability Index (SPADI) Score, and shoulder active range of motion (AROM). The mechanical properties of the deltoid and trapezius muscles were assessed using the MyotonPRO (Myoton AS, Tallinn, Estonia). RESULTS The mrESWT resulted in statistically significant reductions in night pain at 6 weeks (η<inf>p</inf>2=0.27, P=0.003). Significantly improved function (SPADI scores: -35.42±21.29 vs.-29.59±22.60; η<inf>p</inf>2=0.39, P˂0.001) was found in both hrESWT and mrESWT group by 6 weeks. Significantly higher mean shoulder AROM values were recorded for external rotation (η<inf>p</inf>2=0.53, P<0.001), and internal rotation (η<inf>p</inf>2=0.21, P=0.020), in the hrESWT group at the 6th week. A significantly improved resting tone (η<inf>p</inf>2=0.58) and stiffness of deltoid muscle (η<inf>p</inf>2=0.62) were found in the mrESWT group (P<0.001). The trapezius muscle resting tone reduced with hrESWT (η<inf>p</inf>2=0.17, P=0.033). CONCLUSIONS Regardless of the energy levels, rESWT appears to be an effective therapeutic intervention for frozen shoulder patients with type 2 diabetes mellitus in the short-term results. CLINICAL REHABILITATION IMPACT Our results suggest that this rESWT can be a useful strategy for the rehabilitation of frozen shoulder patients with type 2 diabetes mellitus. This is the first study on dose difference effectiveness in terms of the clinical significance of rESWT which is key to transfer research evidence into practice.
Collapse
Affiliation(s)
- Tülay Ç Saldiran
- School of Health Sciences, Department of Physiotherapy and Rehabilitation, Bitlis Eren University, Bitlis, Turkey -
| | - Pelin Yazgan
- Department of Physical Therapy and Medicine, Faculty of Medicine, Istanbul Okan University, Istanbul, Turkey
| | - Ahmet C Akgöl
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Istanbul Okan University, Istanbul, Turkey
| | - Fatma K Mutluay
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Istanbul Medipol University, Istanbul, Turkey
| |
Collapse
|
8
|
Comparison of Surgeon Muscular Properties between Standard Operating Microscope and Digitally Assisted Vitreoretinal Surgery Systems. Retina 2022; 42:1583-1591. [PMID: 35333840 DOI: 10.1097/iae.0000000000003482] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To quantitatively analyze surgical ergonomics between standard operating microscope (SOM) and digitally assisted vitreoretinal surgery (DAVS) systems. METHODS The surgeon conducted procedures on 110 patients; 52 patients underwent a combined phacoemulsification and pars plana vitrectomy (Phaco-PPV group, 24 using SOM and 28 using DAVS), and 58 patients underwent phacoemulsification (Phaco group, 30 using SOM and 28 using DAVS). The surgeon's muscle tone and stiffness in the sternocleidomastoid (SCM) and the two positions of the upper trapezius (UT), which are 2 cm intervals along the UT muscle fibers, UT1 and UT2, were measured at preoperative, intraoperative, and postoperative time points. RESULTS In the Phaco-PPV group using the SOM, intraoperative muscle tone and stiffness were higher than pre- and postoperative values in the SCM (P<0.001, respectively), UT1 (P<0.001, respectively), and UT2 (P<0.001 and P<0.01, respectively). In the Phaco group using the SOM, intraoperative muscle tone and stiffness were higher than pre- and postoperative values in the SCM (P<0.001, respectively) and UT1 (P<0.001 and P<0.01, respectively). By contrast, when the surgeon used the DAVS, there were no differences in muscle properties at any measurement site or during any time point in the Phaco-PPV and Phaco groups (P>0.05). CONCLUSIONS This study provides quantitative measurement of retina surgeon ergonomics, suggesting that compared with a SOM, the DAVS can reduce intraoperative muscle fatigue.
Collapse
|
9
|
Garcia-Bernal MI, Heredia-Rizo AM, Gonzalez-Garcia P, Cortés-Vega MD, Casuso-Holgado MJ. Validity and reliability of myotonometry for assessing muscle viscoelastic properties in patients with stroke: a systematic review and meta-analysis. Sci Rep 2021; 11:5062. [PMID: 33658623 PMCID: PMC7930253 DOI: 10.1038/s41598-021-84656-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Accepted: 02/16/2021] [Indexed: 01/31/2023] Open
Abstract
There is a lack of consensus about the measurement of the muscle viscoelastic features in stroke patients. Additionally, the psychometric properties of the most-commonly used clinical tools remain controversial. Our objective is to investigate the validity and reliability of myotonometry to assess viscoelastic muscle features in stroke survivors. Pubmed, PEDro, Scopus and Cinahl were systematically searched to include studies reporting the psychometric properties of myotonometric devices used in people after stroke. The QUADAS-2 and the COSMIN checklists were used to assess the methodological quality of the studies and the psychometric properties of myotonometry. Nine studies were included in the qualitative synthesis and data from five of these were pooled in a meta-analysis. Overall, low to moderate risk of bias and applicability concerns were observed. Pooled data from intra-rater reliability for muscle tone showed a mean coefficient of correlation of 0.915 (95% CI: 0.880-0.940, I 2 = 69.2%) for upper limbs, and a mean coefficient of 0.785 (95%CI: 0.708-0.844, I 2 = 4.02%) for lower limbs. Myotonometry seems to be a valid and reliable complementary tool to assess muscle viscoelastic properties in stroke survivors, although definite conclusions about concurrent validity need further research.
Collapse
Affiliation(s)
- Maria-Isabel Garcia-Bernal
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - Alberto Marcos Heredia-Rizo
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - Paula Gonzalez-Garcia
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - María-Dolores Cortés-Vega
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - María Jesús Casuso-Holgado
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| |
Collapse
|
10
|
Gilbert I, Gaudreault N, Gaboury I. Intra- and inter-evaluator reliability of the MyotonPRO for the assessment of the viscoelastic properties of caesarean section scar and unscarred skin. Skin Res Technol 2020; 27:370-375. [PMID: 33084197 DOI: 10.1111/srt.12956] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 09/05/2020] [Indexed: 12/30/2022]
Abstract
BACKGROUND The clinical evaluation of viscoelastic properties of the Caesarean section (C-section) scar, such as stiffness and elasticity, is usually carried out using subjective scales and palpation techniques. There is currently no reliable and valid tool that objectively quantifies these properties. The MyotonPRO could fill this gap. MATERIALS AND METHODS Nineteen healthy women aged between 21 and 40 years with C-section scars participated in this reliability study. Two points, one on the scar and one on unscarred skin, were measured four times successively with the MyotonPRO by three independent evaluators on the same day. The intra-class correlation (ICC) coefficients were estimated using a two-factor ANOVA to determine the inter- and intra-rater reliability. The capacity of the MyotonPRO to discriminate the viscoelastic properties of the C-Section scar against unscarred skin was assessed using the Wilcoxon signed rank test. RESULTS The intra- and inter-rater reliability of the viscoelastic property measurements was good to excellent (ICC 0.99-1.00 and 0.87-0.98, respectively). There was no significant difference between C-section scar and unscarred skin in terms of elasticity (P = .737). Significant differences between C-section scars and unscarred skin tissue were observed for tone (P < .001), stiffness (P < .001), creep (P < .001), and mechanical stress relaxation time (P < .001). CONCLUSION The MyotonPRO is a reliable tool for an objective measurement of the viscoelastic properties of the C-section scar and unscarred skin. The MyotonPRO can discriminate the viscoelastic properties of the C-section scar against the unscarred skin, for tone, stiffness, creep and relaxation times, but not for elasticity.
Collapse
Affiliation(s)
- Isabelle Gilbert
- School of Rehabilitation, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, Quebec, Canada.,Department of Family Medicine and Emergency Medicine, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, Quebec, Canada
| | - Nathalie Gaudreault
- School of Rehabilitation, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, Quebec, Canada
| | - Isabelle Gaboury
- Department of Family Medicine and Emergency Medicine, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, Quebec, Canada
| |
Collapse
|
11
|
Kim Y, An SY, Park W, Hwang JH. Detection of early changes in the muscle properties of the pectoralis major in breast cancer patients treated with radiotherapy using a handheld myotonometer. Support Care Cancer 2020; 29:2581-2590. [PMID: 32959155 DOI: 10.1007/s00520-020-05751-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 09/08/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE The primary aim was to investigate serial changes in the mechanical properties of the pectoralis major (PM), upper trapezius (UT), and sternoclavicular mastoid muscle (SCM) in breast cancer patients undergoing radiotherapy (RT) using a hand-held myotonometer. The secondary aims were to determine changes in subjective symptoms and to identify correlation with subjective results. DESIGN A total of 42 breast cancer patients were enrolled in this longitudinal prospective study. Muscle properties of the PM, UT, and SCM were evaluated before RT, immediately after RT, and 4 months post-RT. Subjective symptom scales of pain and stiffness at rest/stretch of each muscle were evaluated. RESULTS The PM showed significant side-to-side differences; the affected PM showed increased tone, stiffness, and decreased elasticity compared with the unaffected PM. The affected PM and UT showed significant time-dependent interactions. Stiffness of the affected PM at stretching was significantly higher 4 months post-RT than baseline. Only the tone and elasticity of the affected PM were correlated with subjective symptoms. CONCLUSION In breast cancer patients who received RT after surgery, increased tone, stiffness, and decreased elasticity were observed in the affected PM compared with the unaffected side, which sustained four months post-RT. Change in muscle properties immediately after RT preceded subjective stiffness, which worsened significantly 4 months post-RT compared with baseline.
Collapse
Affiliation(s)
- Yoon Kim
- Department of Rehabilitation Medicine, National Rehabilitation Center, Seoul, Republic of Korea
| | - So Yeon An
- Center for Clinical Medicine, Samsung Biomedical Research Institute, Seoul, Republic of Korea
| | - Won Park
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Ji Hye Hwang
- Department of Physical and Rehabilitation Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.
| |
Collapse
|
12
|
Park SJ, Kim SH, Kim SH. Effects of Thoracic Mobilization and Extension Exercise on Thoracic Alignment and Shoulder Function in Patients with Subacromial Impingement Syndrome: A Randomized Controlled Pilot Study. Healthcare (Basel) 2020; 8:healthcare8030316. [PMID: 32887287 PMCID: PMC7551755 DOI: 10.3390/healthcare8030316] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Revised: 08/25/2020] [Accepted: 08/30/2020] [Indexed: 11/28/2022] Open
Abstract
Introduction: Thoracic kyphosis commonly occurs in subacromial impingement syndrome. This pilot study investigated the effect of thoracic joint mobilization and extension exercise on improving thoracic alignment and shoulder function. Methods: In total, 30 patients with subacromial impingement syndrome were recruited and randomly assigned to three groups, the joint mobilization group (n = 10), exercise group (n = 10), and combination group (n = 10). After four weeks of treatment, the measured outcomes included thoracic kyphosis using a manual inclinometer; pectoralis major (PM) and upper trapezius (UT) muscle tone and stiffness using the MyotonPRO®; affected side passive range of motion (ROM) using the goniometer (flexion, abduction, medial rotation, and lateral rotation); and shoulder pain and disability index (SPADI). Results: All three groups had significant improvements in all variables (p < 0.05). Thoracic kyphosis; UT muscle tone; and flexion, medial rotation, and lateral rotation ROM and SPADI were all significantly improved in the combination group compared to the mobilization and exercise groups (p < 0.05). Conclusions: The combination therapy of thoracic mobilization and extension exercise can be regarded as a promising method to improve thoracic alignment and shoulder function in patients with subacromial impingement syndrome.
Collapse
Affiliation(s)
- Shin Jun Park
- Department of Physical Therapy, Gangdong University, 278, Daehak-gil, Gamgok-myeon, Eumseong-gun, Chungcheongbuk-do 27600, Korea;
| | - Seok Hyeon Kim
- Department of Physical Therapy, General Graduate School, Yongin University, 134, Yongindaehak-ro, Cheoin-gu, Yongin-si, Gyeonggi-do 17092, Korea;
| | - Soon Hee Kim
- Department of Physical Therapy, Yongin University, 134, Yongindaehak-ro, Cheoin-gu, Yongin-si, Gyeonggi-do 17092, Korea
- Correspondence: ; Tel.: +82-31-8020-2774; Fax: +82-31-8020-3075
| |
Collapse
|