Colaianni-Alfonso N, Toledo A, Montiel G, Castro-Sayat M, Crimi C, Vetrugno L. High-flow nasal cannula and in-line aerosolised bronchodilator delivery during severe exacerbation of asthma in adults: a feasibility observational study. Anaesth Crit Care Pain Med 2024; 43:101414. [PMID: 39089455 DOI: 10.1016/j.accpm.2024.101414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 07/02/2024] [Accepted: 07/19/2024] [Indexed: 08/04/2024]
Abstract
BACKGROUND Asthma is a common chronic respiratory disease affecting 1-29% of the population in different countries. Exacerbations represent a change in symptoms and lung function from the patient's usual condition that requires emergency department (ED) admission. Recently, the use of a High-Flow Nasal Cannula (HFNC) plus an in-line vibrating mesh nebulizer (VMN) for aerosol drug delivery has been advocated in clinical practice. Thus, this pilot observational study aims to investigate the feasibility of HFNC treatment with VMN for in-line bronchodilator delivery in patients with severe asthma. METHODS This study was conducted from May 2022 to May 2023. Subjects ≥18 years old with a previous diagnosis of asthma who were admitted to the ED during severe exacerbation were included. The primary endpoint was the change in peak expiratory flow ratio (PEFR) after 2-h of treatment with bronchodilator delivered by HFNC with in-line VMN. Additional outcomes were changes in forced expiratory volume in 1 s (FEV1) and clinical variables before treatment. RESULTS 30 patients, mean age of 43 (SD ± 16) years, mostly female (67%) were studied. A significant change in PEFR (147 ± 31 L/m vs. 220 ± 38 L/m; p < 0.001) was observed after treatment with HFNC and in-line VMN with significant improvement in clinical variables. And no subjects required invasive mechanical ventilation (IMV) during the study. CONCLUSIONS HFNC treatment with in-line VMN for bronchodilator delivery appears feasible and safe for patients with severe asthma exacerbation. These preliminary promising results should be confirmed with appropriately large-designed studies.
Collapse
Affiliation(s)
- Nicolás Colaianni-Alfonso
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina.
| | - Ada Toledo
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina
| | - Guillermo Montiel
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina
| | - Mauro Castro-Sayat
- Respiratory Intermediate Care Unit, Hospital Juan A. Fernández, Ciudad Autónoma de Buenos Aires, Argentina
| | - Claudia Crimi
- Respiratory Medicine Unit, Policlinico "G. Rodolico-San Marco" University Hospital, Catania, Italy; Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Luigi Vetrugno
- Department of Medical, Oral and Biotechnological Sciences, University of G. d' Annunzio, Chieti-Pescara, Italy.
| |
Collapse
|
2
|
MacLoughlin R, Mac Giolla Eain M. Performance Characterisation of the Airvo2 TM Nebuliser Adapter in Combination with the Aerogen Solo TM Vibrating Mesh Nebuliser for in Line Aerosol Therapy during High Flow Nasal Oxygen Therapy. Pharmaceutics 2024; 16:565. [PMID: 38675226 PMCID: PMC11053618 DOI: 10.3390/pharmaceutics16040565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 04/16/2024] [Accepted: 04/17/2024] [Indexed: 04/28/2024] Open
Abstract
High flow oxygen (HFO) therapy is a well-established treatment in respiratory disease. Concurrent aerosol delivery can greatly expediate their recovery. The aim of this work was to complete a comprehensive characterisation of one such HFO therapy system, the Airvo2TM, used in combination with the Aerogen SoloTM vibrating mesh nebuliser. Representative adult, infant, and paediatric head models were connected to a breathing simulator via a collection filter placed at the level of the trachea. A tracheostomy interface and nasal cannulas were used to deliver the aerosol. Cannula size and gas flow rate were varied across the full operating range recommended by the manufacturer. The tracheal and emitted doses were quantified via UV-spectrophotometry. The aerosol droplet diameter at the exit of the nares and tracheal interface was measured via cascade impaction. High gas flow rates resulted in low emitted and tracheal doses (%). Nasal cannula size had no significant effect on the tracheal dose (%) available in infant and paediatric models. Higher gas flow rates resulted in smaller aerosol droplets at the exit of the nares and tracheostomy interface. Gas flow rate was found to be the primary parameter affecting aerosol delivery. Thus, gas flow rates should be kept low and where possible, delivered using larger nasal cannulas to maximise aerosol delivery.
Collapse
Affiliation(s)
- Ronan MacLoughlin
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, H91 HE94 Galway, Ireland
- School of Pharmacy and Biomolecular Science, Royal College of Surgeons in Ireland, D02 YN77 Dublin, Ireland
- School of Pharmacy and Pharmaceutical Sciences, Trinity College, D02 PN40 Dublin, Ireland
| | - Marc Mac Giolla Eain
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, H91 HE94 Galway, Ireland
| |
Collapse
|
3
|
Ari A, Raghavan N, Diaz M, Rubin BK, Fink JB. Individualized aerosol medicine: Integrating device into the patient. Paediatr Respir Rev 2024; 49:14-23. [PMID: 37739833 DOI: 10.1016/j.prrv.2023.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 07/12/2023] [Indexed: 09/24/2023]
Abstract
Pulmonary drug delivery is complex due to several challenges including disease-, patient-, and clinicians-related factors. Although many inhaled medications are available in aerosol medicine, delivering aerosolized medications to patients requires effective disease management. There is a large gap in the knowledge of clinicians who select and provide instructions for the correct use of aerosol devices. Since improper device selection, incorrect inhaler technique, and poor patient adherence to prescribed medications may result in inadequate disease control, individualized aerosol medicine is essential for effective disease management and control. The components of individualized aerosol medicine include: (1) Selecting the right device, (2) Selecting the right interface, (3) Educating the patient effectively, and (4) Increasing patient adherence to therapy. This paper reviews each of these components and provides recommendations to integrate the device and interface into the patient for better clinical outcomes.
Collapse
Affiliation(s)
- Arzu Ari
- Texas State University, Department of Respiratory Care, USA.
| | | | - Martha Diaz
- Latin American Board of Certification in Respiratory Therapy, Colombia
| | - Bruce K Rubin
- Virginia Commonwealth University School of Medicine, USA.
| | - James B Fink
- Texas State University, Department of Respiratory Care, USA; Aerogen Pharma, USA.
| |
Collapse
|
4
|
Reilly L, Mac Giolla Eain M, Murphy S, O’Sullivan A, Joyce M, MacLoughlin R. An in vitro study of the effects of respiratory circuit setup and parameters on aerosol delivery during mechanical ventilation. Front Med (Lausanne) 2024; 10:1307301. [PMID: 38327274 PMCID: PMC10847248 DOI: 10.3389/fmed.2023.1307301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 12/26/2023] [Indexed: 02/09/2024] Open
Abstract
Introduction Aerosol therapy is often prescribed concurrently during invasive mechanical ventilation (IMV). This study determines the effects of nebuliser position, circuit humidification source, and most importantly, lung health on the delivery of aerosol in simulated adult and paediatric IMV patients. Furthermore, the influence of closed suction catheters on aerosol delivery is also addressed. Methods A vibrating mesh nebuliser was used to deliver Albuterol to simulated adult and paediatric IMV patients with differing states of lung health. Four different nebuliser positions and two types of humidification were analysed. Closed suction catheter mounts, a mainstay in IMV therapy, were incorporated into the circuits. The mean ± SD dose of aerosol (%) was assayed from a filter at the distal end of the endotracheal tube. Results Nebuliser placement and circuit humidification source had no effect on the delivered dose (%) in adults, yet both significantly did in the simulated paediatric patients. The use of closed suction catheter mounts significantly reduced the delivered dose (%) in adults but not in paediatric patients. A simulated healthy lung state generated the largest delivered dose (%), irrespective of nebuliser position in the adult. However, different lung health and nebuliser positions yielded higher delivered doses (%) in paediatrics. Conclusion Lung health and respiratory circuit composition significantly affect aerosol delivery in both adult and paediatric IMV patients. Nebuliser placement and respiratory circuit humidification source do not affect the delivered dose in adult but do in paediatric IMV patients.
Collapse
Affiliation(s)
- Leanne Reilly
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Marc Mac Giolla Eain
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Sarah Murphy
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Andrew O’Sullivan
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Mary Joyce
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Ronan MacLoughlin
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
- School of Pharmacy & Biomolecular Science, Royal College of Surgeons in Ireland, Dublin, Ireland
- School of Pharmacy and Pharmaceutical Sciences, Trinty College, Dublin, Ireland
| |
Collapse
|
5
|
Preston HE, Bayliss R, Temperton N, Neto MM, Brewer J, Parker AL. Capture and inactivation of viral particles from bioaerosols by electrostatic precipitation. iScience 2023; 26:107567. [PMID: 37664619 PMCID: PMC10470311 DOI: 10.1016/j.isci.2023.107567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 06/11/2023] [Accepted: 08/07/2023] [Indexed: 09/05/2023] Open
Abstract
Infectious viral particles in bioaerosols generated during laparoscopic surgery place staff and patients at significant risk of infection and contributed to the postponement of countless surgical procedures during the COVID-19 pandemic causing excess deaths. The implementation of devices that inactivate viral particles from bioaerosols aid in preventing nosocomial viral spread. We evaluated whether electrostatic precipitation (EP) is effective in capturing and inactivating aerosolized enveloped and non-enveloped viruses. Using a closed-system model mimicking release of bioaerosols during laparoscopic surgery, known concentrations of each virus were aerosolized, exposed to EP and collected for analysis. We demonstrate that both enveloped and non-enveloped viral particles were efficiently captured and inactivated by EP, which was enhanced by increasing the voltage to 10 kV or using two discharge electrodes together at 8 kV. This study highlights EP as an effective means for capturing and inactivating viral particles in bioaerosols, which may enable continued surgical procedures during future pandemics.
Collapse
Affiliation(s)
- Hannah E. Preston
- Division of Cancer and Genetics, Cardiff University School of Medicine, Heath Park, Cardiff CF14 4XN, UK
| | - Rebecca Bayliss
- Division of Cancer and Genetics, Cardiff University School of Medicine, Heath Park, Cardiff CF14 4XN, UK
| | - Nigel Temperton
- Viral Pseudotype Unit, Medway School of Pharmacy, University of Kent, Central Avenue, Chatham ME4 4BF, UK
| | - Martin Mayora Neto
- Viral Pseudotype Unit, Medway School of Pharmacy, University of Kent, Central Avenue, Chatham ME4 4BF, UK
| | - Jason Brewer
- Alesi Surgical Ltd, Medicentre, Heath Park Way, Cardiff CF14 4UJ, UK
| | - Alan L. Parker
- Division of Cancer and Genetics, Cardiff University School of Medicine, Heath Park, Cardiff CF14 4XN, UK
- Systems Immunity University Research Institute, Cardiff University School of Medicine, Heath Park, Cardiff CF14 4XN, UK
| |
Collapse
|
6
|
MacLoughlin R, Martin-Loeches I. Not all nebulizers are created equal: Considerations in choosing a nebulizer for aerosol delivery during mechanical ventilation. Expert Rev Respir Med 2023; 17:131-142. [PMID: 36803134 DOI: 10.1080/17476348.2023.2183194] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
INTRODUCTION Aerosol therapy is commonly prescribed in the mechanically ventilated patient. Jet nebulizers (JN) and vibrating mesh nebulizers (VMN) are the most common nebulizer types, however, despite VMN's well established superior performance, JN use remains the most commonly used of the two. In this review, we describe the key differentiators between nebulizer types and how considered selection of nebulizer type may enable successful therapy and the optimization of drug/device combination products. AREAS COVERED Following a review of the published literature up to February 2023, the current state of the art in relation to JN and VMN is discussed under the headings of in vitro performance of nebulizers during mechanical ventilation, respective compatibility with formulations for inhalation, clinical trials making use of VMN during mechanical ventilation, distribution of nebulized aerosol throughout the lung, measuring the respective performance of nebulizers in the patient and non-drug delivery considerations in nebulizer choice. EXPERT OPINION Whether for standard care, or the development of drug/device combination products, the choice of nebulizer type should not be made without consideration of the unique needs of the combination of each of drug, disease and patient types, as well as target site for deposition, and healthcare professional and patient safety.
Collapse
Affiliation(s)
- Ronan MacLoughlin
- Research and Development, Science and Emerging Technologies, Aerogen Ltd, Dangan, Ireland.,School of Pharmacy and Pharmaceutical Sciences, Trinity College, Dublin, Ireland.,School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland (RCSI), Dublin, Ireland
| | - Ignacio Martin-Loeches
- Department of Intensive Care Medicine, Multidisciplinary Intensive Care Research Organization (MICRO), Dublin, Ireland
| |
Collapse
|