Jiang L, Thall PF, Yan F, Kopetz S, Yuan Y. BASIC: A Bayesian adaptive synthetic-control design for phase II clinical trials.
Clin Trials 2023;
20:486-496. [PMID:
37313712 PMCID:
PMC10504821 DOI:
10.1177/17407745231176445]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND
Randomized controlled trials are considered the gold standard for evaluating experimental treatments but often require large sample sizes. Single-arm trials require smaller sample sizes but are subject to bias when using historical control data for comparative inferences. This article presents a Bayesian adaptive synthetic-control design that exploits historical control data to create a hybrid of a single-arm trial and a randomized controlled trial.
METHODS
The Bayesian adaptive synthetic control design has two stages. In stage 1, a prespecified number of patients are enrolled in a single arm given the experimental treatment. Based on the stage 1 data, applying propensity score matching and Bayesian posterior prediction methods, the usefulness of the historical control data for identifying a pseudo sample of matched synthetic-control patients for making comparative inferences is evaluated. If a sufficient number of synthetic controls can be identified, the single-arm trial is continued. If not, the trial is switched to a randomized controlled trial. The performance of The Bayesian adaptive synthetic control design is evaluated by computer simulation.
RESULTS
The Bayesian adaptive synthetic control design achieves power and unbiasedness similar to a randomized controlled trial but on average requires a much smaller sample size, provided that the historical control data patients are sufficiently comparable to the trial patients so that a good number of matched controls can be identified in the historical control data. Compared to a single-arm trial, The Bayesian adaptive synthetic control design yields much higher power and much smaller bias.
CONCLUSION
The Bayesian adaptive synthetic-control design provides a useful tool for exploiting historical control data to improve the efficiency of single-arm phase II clinical trials, while addressing the problem of bias when comparing trial results to historical control data. The proposed design achieves power similar to a randomized controlled trial but may require a substantially smaller sample size.
Collapse