1
|
Some Applications of Liquid Chromatography-Mass Spectrometry in the Biomedical Field. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/bs.coac.2017.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
2
|
Assessing cocaine abuse using LC-MS/MS measurements in biological specimens. Bioanalysis 2016; 7:1497-525. [PMID: 26168256 DOI: 10.4155/bio.15.72] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
Cocaine use is still a problem in today's world, and this has several implications on human activities. Indeed, important problems related to cocaine derive from its use in situations where concentration and focus skills are necessary, namely while driving and/or working. The need of analytical methods for drug analysis in specimens of biological origin for proper documentation of human exposure is increasing. While GC-MS-based procedures represented the state-of-the-art of analytical techniques a few years ago, there is a growing trend for their replacement by LC-MS/MS, which can be justified by the increased sensitivity presented by these new technologies. This paper will review recently published papers on the use of LC-MS/MS-based procedures for cocaine measurement in biological specimens.
Collapse
|
3
|
Vogliardi S, Tucci M, Stocchero G, Ferrara SD, Favretto D. Sample preparation methods for determination of drugs of abuse in hair samples: A review. Anal Chim Acta 2015; 857:1-27. [DOI: 10.1016/j.aca.2014.06.053] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Revised: 06/28/2014] [Accepted: 06/30/2014] [Indexed: 10/24/2022]
|
4
|
Kang K, Sachan A, Nilsen-Hamilton M, Shrotriya P. Aptamer functionalized microcantilever sensors for cocaine detection. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:14696-14702. [PMID: 21875108 DOI: 10.1021/la202067y] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A cocaine-specific aptamer was used as a receptor molecule in a microcantilever-based surface stress sensor for detection of cocaine molecules. An interferometric technique that relies on measuring differential displacement between two microcantilevers (a sensing/reference pair) was utilized to measure the cocaine/aptamer binding induced surface stress changes. Sensing experiments were performed for different concentrations of cocaine from 25 to 500 μM in order to determine the sensor response as a function of cocaine concentration. In the lower concentration range from 25 to 100 μM, surface stress values increased proportionally to coverage of aptamer/cocaine complexes from 11 to 26 mN/m. However, as the cocaine concentration was increased beyond 100 μM, the surface stress values demonstrated a weaker dependence on the affinity complex surface coverage. On the basis of a sensitivity of 3 mN/m for the surface stress measurement, the lowest detectable threshold for the cocaine concentration is estimated to be 5 μM. Sensing cantilevers could be regenerated and reused because of reversible thermal denaturation of aptamer.
Collapse
Affiliation(s)
- Kyungho Kang
- Department of Mechanical Engineering, Iowa State University, Ames, Iowa 50011, USA
| | | | | | | |
Collapse
|
5
|
Favretto D, Vogliardi S, Stocchero G, Nalesso A, Tucci M, Ferrara SD. High performance liquid chromatography–high resolution mass spectrometry and micropulverized extraction for the quantification of amphetamines, cocaine, opioids, benzodiazepines, antidepressants and hallucinogens in 2.5mg hair samples. J Chromatogr A 2011; 1218:6583-95. [DOI: 10.1016/j.chroma.2011.07.050] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Revised: 06/28/2011] [Accepted: 07/14/2011] [Indexed: 10/18/2022]
|
6
|
Conti M, Tazzari V, Bertona M, Brambilla M, Brambilla P. Surface-activated chemical ionization combined with electrospray ionization and mass spectrometry for the analysis of cannabinoids in biological samples. Part I: analysis of 11-nor-9-carboxytetrahydro-cannabinol. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:1552-8. [PMID: 21594929 DOI: 10.1002/rcm.5029] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Recently, electrospray ionization mass spectroscopy (ESI-MS) has been widely used for the identification of drugs of abuse and their metabolites in biological samples. However, the sensitivity and selectivity of this technique are commonly inadequate for the analysis of tetrahydrocannabinol (THC) and its metabolites at very low levels, such as those sometimes required in forensic and clinical-legal applications. We coupled electrospray ionization and surface-activated chemical ionization (ESI-SACI) to various types of mass analyzers (ion trap, triple quadrupole and orbitrap) (ESI-SACI-MS) to improve the detection of 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH), the most common marker of THC abuse. The benefits of this approach in terms of sensitivity and selectivity compared with a common ESI-MS approach are clearly demonstrated.
Collapse
Affiliation(s)
- Matteo Conti
- Laboratory of Clinical Pharmacology and Toxicology, S. Maria delle Croci Ravenna Hospital, Viale Randi 5, Ravenna, IT 48100, Italy.
| | | | | | | | | |
Collapse
|
7
|
Bioanalytical methods for the determination of cocaine and metabolites in human biological samples. Bioanalysis 2011; 1:977-1000. [PMID: 21083066 DOI: 10.4155/bio.09.72] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Determination of cocaine and its metabolites in biological specimens is of great importance, not only in clinical and forensic toxicology, but also in workplace drug testing. These compounds are normally screened for using sensitive immunological methods. However, screening methods are unspecific and, therefore, the posterior confirmation of presumably positive samples by a specific technique is mandatory. Although GC-MS-based techniques are still the most commonly used for confirmation purposes of cocaine and its metabolites in biological specimens, the advent of LC-MS and LC-MS/MS has enabled the detection of even lower amounts of these drugs, which assumes particular importance when sample volume available is small, as frequently occurs with oral fluid. This paper will review recently-published papers that describe procedures for detection of cocaine and metabolites, not only in the most commonly used specimens, such as blood and urine, but also in other 'alternative' matrices (e.g., oral fluid and hair) with a special focus on sample preparation and chromatographic analysis.
Collapse
|
8
|
Quintela O, Lendoiro E, Cruz A, de Castro A, Quevedo A, Jurado C, López-Rivadulla M. Hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC-MS/MS) determination of cocaine and its metabolites benzoylecgonine, ecgonine methyl ester, and cocaethylene in hair samples. Anal Bioanal Chem 2010; 396:1703-12. [DOI: 10.1007/s00216-009-3393-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2009] [Revised: 11/30/2009] [Accepted: 12/08/2009] [Indexed: 10/20/2022]
|
9
|
Bucelli F, Fratini A, Bavazzano P, Comodo N. Quantification of drugs of abuse and some stimulants in hair samples by liquid chromatography-electrospray ionization ion trap mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:3931-6. [PMID: 19864191 DOI: 10.1016/j.jchromb.2009.09.026] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2009] [Revised: 09/15/2009] [Accepted: 09/18/2009] [Indexed: 11/28/2022]
Abstract
A qualitative and quantitative method for the analysis of drugs of abuse (cocaine and benzoylecgonine, opiates) and some stimulants in human hair was developed and validated. Hair samples were incubated with phosphate buffer (pH 5.0), chosen as the extraction medium, extracted with Bond Elut Certify cartridges and analyzed by LC-MS-MS and LC-MS(3) as confirmation for positive results. The method proved to be specific, accurate and precise across the calibration range (0.1-30 ng/mg) where good linearity was observed. Total extraction recovery, intra-assay accuracy and precision, limits of detection and limits of quantitation were estimated. The method was successfully applied to the analysis of hair samples collected from drug abusers and it was suitable for routine analytical applications in the Antidoping Laboratory of Public Health Laboratory.
Collapse
Affiliation(s)
- Francesca Bucelli
- Università di Firenze, Dipartimento di Sanità pubblica, Viale Morgagni 48, 50134 Firenze, Italy.
| | | | | | | |
Collapse
|
10
|
Trevorrow P. Launch Editorial. Drug Test Anal 2009; 1:1-3. [DOI: 10.1002/dta.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
11
|
Su HL, Feng LI, Jen HP, Hsieh YZ. Determination of cocaine and its metabolites using cation-selective exhaustive injection and sweeping-MEKC. Electrophoresis 2008; 29:4270-6. [DOI: 10.1002/elps.200800167] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
12
|
Barroso M, Dias M, Vieira DN, Queiroz JA, López-Rivadulla M. Development and validation of an analytical method for the simultaneous determination of cocaine and its main metabolite, benzoylecgonine, in human hair by gas chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:3320-3326. [PMID: 18819113 DOI: 10.1002/rcm.3738] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A new, simple and rapid procedure has been developed and validated for the determination of cocaine and its main metabolite, benzoylecgonine, in human hair samples. After extraction from within the hair matrix by a mixture of methanol/hydrochloric acid (2:1) at 65 degrees C for 3 h, and sample cleanup by mixed-mode solid-phase extraction (SPE), the extracts were analyzed by gas chromatography/mass spectrometry (GC/MS), after derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide with 5% chlorotrimethylsilane. Using a sample size of only 20 mg of hair, limits of detection (LODs) and quantitation (LOQs) were, respectively, 20 and 50 pg/mg for cocaine, and 15 and 50 pg/mg for benzoylecgonine, achieving the cut-off values proposed by the Society of Hair Testing for the analysis of these compounds in hair. The method was found to be linear (weighing factor of 1/x) between the LOQ and 20 ng/mg for both compounds, with correlation coefficients ranging from 0.9974 to 0.9996 for cocaine; and from 0.9981 to 0.9994 for benzoylecgonine. Intra- and interday precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The sample cleanup step presented a mean absolute recovery greater than 90% for both compounds. The developed method may be useful in forensic toxicology laboratories for the analysis of cocaine and benzoylecgonine in hair samples, taking into account its speed (only 3 h are required for the extraction of the analytes from within the matrix, whereas 5 h or even overnight extractions have been reported) and the low limits achieved (using a single quadrupole mass spectrometer, which is available in most laboratories).
Collapse
Affiliation(s)
- M Barroso
- Instituto Nacional de Medicina Legal - Delegação do Sul, Rua Manuel Bento de Sousa, 3, 1150-219 Lisboa, Portugal.
| | | | | | | | | |
Collapse
|
13
|
Gallardo E, Queiroz JA. The role of alternative specimens in toxicological analysis. Biomed Chromatogr 2008; 22:795-821. [DOI: 10.1002/bmc.1009] [Citation(s) in RCA: 135] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
14
|
Cristoni S, Crotti S, Zingaro L, Bernardi LR, Gottardo R, Politi L, Polettini A, Tagliaro F. On the coupling of ion-exchange chromatography to surface-activated chemical ionization in the analysis of highly polar metabolites in diluted urine samples. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:2134-2138. [PMID: 18523975 DOI: 10.1002/rcm.3590] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
15
|
Current awareness in phytochemical analysis. PHYTOCHEMICAL ANALYSIS : PCA 2008; 19:91-98. [PMID: 18340659 DOI: 10.1002/pca.1036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
16
|
Flamini R, Vedova AD, De Rosso M, Panighel A. A new sensitive and selective method for analysis of ochratoxin A in grape and wine by direct liquid chromatography/surface-activated chemical ionization tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:3737-3742. [PMID: 17952890 DOI: 10.1002/rcm.3275] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A new sensitive and selective analytical method for the analysis of ochratoxin A (OTA) in grape and wine was developed by coupling liquid chromatography and surface activated chemical ionization and mass spectrometry with multistage fragmentation (LC/SACI-MS(3)). A high flow gradient was used to strongly reduce the matrix effect phenomenon, and the wine sample was directly injected onto the chromatographic column without sample pre-concentration or purification steps. The amount of OTA was determined for two grape extracts and the amount of OTA, percent accuracy error and percent precision error were analyzed for 15 wine samples. An excellent limit of detection of 0.02 ng/mL was achieved, and the limit of quantification was at least 20-fold lower than the maximum legal limit for OTA (2 ppb). Due to the low limit of quantification, this novel method is a potential tool for official OTA screening purposes.
Collapse
Affiliation(s)
- Riccardo Flamini
- CRA, Istituto Sperimentale per la Viticoltura, viale XXVIII aprile 26, 31015 Conegliano (TV), Italy.
| | | | | | | |
Collapse
|