1
|
Nishijo N, Hayama T, Tomita R, Fujioka T. Accurate LC-MS/MS Analysis of Diacylglycerols in Human Plasma with Eliminating Matrix Effect by Phospholipids Using Fluorous Biphasic Extraction. Anal Chem 2023; 95:14898-14904. [PMID: 37767921 DOI: 10.1021/acs.analchem.3c01998] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
We developed an accurate method for determining diacylglycerols (DAGs) in human plasma using a fluorous biphasic liquid-liquid extraction method, followed by liquid chromatography with tandem mass spectrometry (LC-MS/MS) analysis. The lipid mixture in the plasma was first extracted with chloroform by using the Bligh-Dyer method. The resulting solution was subjected to fluorous biphasic liquid-liquid extraction to remove phospholipids, which are known to cause matrix effects during the LC-MS/MS analysis. In this method, phospholipids in a lipid mixture solution (nonfluorous solvent) were selectively extracted to tetradecafluorohexane (fluorous solvent) via the specificity of fluorous affinity by forming a complex with a perfluoropolyethercarboxylic acid-lanthanum(III) salt. The remaining DAGs in the nonfluorous solvent could be directly injected into the LC system through the positive electrospray ionization-MS/MS mode. The removal rate of the phospholipids through the fluorous biphasic extraction was more than 99.9%; thus, the matrix-effect-eliminating analysis of DAGs in human plasma with LC-MS/MS was enabled. Furthermore, the applicability of this method and the possibility of using DAGs as biomarkers were evaluated by applying this method to human plasma samples obtained from major depressive disorder as a related disease.
Collapse
Affiliation(s)
- Nao Nishijo
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Tadashi Hayama
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Ryoko Tomita
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Toshihiro Fujioka
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| |
Collapse
|
2
|
Wang Y, Bao L, Sun J, Ding Y, Shi J, Duan Z, Chen Z. Superhydrophobic fluorinated microspheres for fluorous affinity chromatography. J Chromatogr A 2022; 1680:463428. [PMID: 36001909 DOI: 10.1016/j.chroma.2022.463428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/14/2022] [Accepted: 08/17/2022] [Indexed: 11/16/2022]
Abstract
Fluorous affinity chromatography has received growing attention in separation and purification of fluoro compounds, but the wettability of the fluorinated stationary phases is seldom noticed. Here, we construct a series of micro-sized fluorine-containing microspheres by solvothermal precipitation polymerization. The fluorinated microspheres could be obtained with narrow size distribution at even high monomer loading of 15 wt%. Through alternating fluoro monomer, both the particle size and the wettability of the microsphere array could be tuned. Among them, the poly(divinylbenzene -dodecafluoroheptyl methacrylate), P(DVB-DFHMA), microsphere (6.1 μm) arrays displays superhydrophobicity with 153.2° water contact angle. The P(DVB-DFHMA) fluorinated microspheres (7.58% fluorine content) can be packed into steel-less columns as stationary phase for high-performance liquid chromatography. The retention mechanism of the fluorinated column is proven to be the specific fluorine-fluorine interaction. Compared to the commercial C18 silica column, the fluorinated column can completely separate fluorine-containing compounds under high water content mobile phase, including small fluoro molecules and fluoro macromolecules, at much lower back pressure by fluorous affinity.
Collapse
Affiliation(s)
- Yanyan Wang
- Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Liuqian Bao
- Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Jiajing Sun
- Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Yuanyuan Ding
- Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Jiasheng Shi
- Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Zhengyu Duan
- Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Zhiyong Chen
- Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China.
| |
Collapse
|
3
|
SAKAGUCHI Y. Derivatization LC for the Sensitivity and Accuracy Bioanalysis. BUNSEKI KAGAKU 2022. [DOI: 10.2116/bunsekikagaku.71.307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
4
|
Dogra R, Kumar M, Kumar A, Roverso M, Bogialli S, Pastore P, Mandal UK. Derivatization, an Applicable Asset for Conventional HPLC Systems without MS Detection in Food and Miscellaneous Analysis. Crit Rev Anal Chem 2022; 53:1807-1827. [PMID: 35201944 DOI: 10.1080/10408347.2022.2042671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
One of the most valuable practices for analyzing not-so-analytical-friendly analytes in complex, heterogenous matrices is derivatization. Availability of numerous derivatizing reagents (DRs) makes the modification of analyte more exploitable in terms of an analytical perspective. A wide array of derivatization techniques like pre or post-column, in-situ, enzymatic, ultrasound-assisted, microwave-assisted, photochemical derivatization has added much-needed methodological strength in analyzing intricate analytical matrices (food, water, and soil). In recent years, analytical chemistry has achieved greater heights through the development of new sensitive methods with simple conventional instruments like High-Performance Liquid Chromatography (HPLC) devoid of Mass detectors. The prompt availability of these straightforward instruments also makes it a favorable option for routine analysis in food, environmental, bioanalytical chemistry. Analyzing food, environmental or bioanalytical specimen has some of the most problematic aspects, like the low concentration of the analytes accompanied by not too suitable analytical properties. Even though conventional HPLC lacks the required sensitivity but merger with derivatization can lead to a remarkable increase in sensitivity. In recent years there has been a lot of application of diverse derivatizations to increase the sensitivity and selectivity of the analyte for available instruments, resulting in notable findings. Therefore, this review describes the application of derivatization principles in the analysis of analytes in food and additional matrices using conventional HPLC instruments such as HPLC-UV, HPLC-DAD, and HPLC-FD. In this article, we will briefly review the different modes and multiple types of derivatizing reagents with their mechanisms and importance for encouraging the use of established HPLC instruments.
Collapse
Affiliation(s)
- Raghav Dogra
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Mohit Kumar
- Department of Pharmaceutical Sciences & Technology, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| | - Arvind Kumar
- Maharaja Agrasen University, Baddi, Solan, Himachal Pradesh, India
| | - Marco Roverso
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Sara Bogialli
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Paolo Pastore
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Uttam Kumar Mandal
- Department of Pharmaceutical Sciences & Technology, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| |
Collapse
|
5
|
Sakaguchi Y, Kawamura R, Nakayama E, Ako K, Kawasue S, Koga R, Yoshida H, Nohta H. Selective analysis of the okadaic acid group in shellfish samples using fluorous derivatization coupled with liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1173:122681. [PMID: 33878533 DOI: 10.1016/j.jchromb.2021.122681] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/04/2021] [Accepted: 03/27/2021] [Indexed: 10/21/2022]
Abstract
Okadaic acid (OA) group are diarrheal shellfish poison that accumulates in the midgut glands of shellfish. It is difficult to remove these poisons by normal cooking because they are thermally stable and hydrophobicity. Therefore, in order to prevent foodborne disease due to shellfish poison, analysis by liquid chromatography (LC)-tandem mass spectrometry (MS/MS) before shipment is necessary. Herein the selective analytical method for OA group in shellfish sample using fluorous derivatization coupled with LC-MS/MS was developed. OA group were derivatized with the fluorous alkylamine reagent by condensing agent, and the obtained derivatives were separated with fluorous LC column (Fluofix-II 120E, 250 × 2.0 mm i.d., 5 μm, Fujifilm Wako Pure Chemical). The derivatized OA group were selective retained by fluorous LC column and accurate analysis was enabled. The present method was applied to the analysis of OA and dinophysistoxin-1 (DTX-1) in scallop midgut gland which is the certified reference material provided by national metrology institute of Japan. As a result of analysis using the present method with DTX-2 as the internal standard, the quantitative value were in agreement with the certified value.
Collapse
Affiliation(s)
- Yohei Sakaguchi
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Rina Kawamura
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Erina Nakayama
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Kenta Ako
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Shimba Kawasue
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Reiko Koga
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Hideyuki Yoshida
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan
| | - Hitoshi Nohta
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka 814-0180, Japan.
| |
Collapse
|
6
|
Tomita R, Hayama T, Nishijo N, Fujioka T. Fluorous and Fluorogenic Derivatization for Selective Liquid Chromatographic Analysis of Cyanide in Human Plasma. ANAL SCI 2020; 36:1251-1254. [PMID: 32475896 DOI: 10.2116/analsci.20p103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A liquid chromatographic (LC) method with fluorous derivatization for the determination of cyanide in human plasma is described. In this method, the cyanide was transformed to a fluorous and fluorogenic compound by derivatizing with 2,3-naphthalenedialdehyde and perfluoroalkylamine reagent under mild reaction conditions (a reaction time of 5 min at room temperature). The obtained derivative was successfully retained on the perfluoroalkyl-modified LC column with the use of a high concentration of organic solvent in the mobile phase, whereas non-fluorous derivative was hardly retained, followed by fluorometric detection at excitation and emission wavelengths of 420 and 490 nm, respectively. Under the optimized conditions, the limit of detection and the limit of quantification for cyanide in a 5-μL injection volume were 1.3 μg/L (S/N = 3) and 4.4 μg/L (S/N = 10), respectively. The recovery from spiked human plasma was achieved in the range of 54 - 90% within a relative standard deviation of 3.5%. The feasibility of this method was further evaluated by applying it to the analysis of human plasma samples.
Collapse
Affiliation(s)
- Ryoko Tomita
- Faculty of Pharmaceutical Sciences, Fukuoka University
| | | | - Nao Nishijo
- Faculty of Pharmaceutical Sciences, Fukuoka University
| | | |
Collapse
|
7
|
Zheng JY, Jin YY, Shi ZQ, Zhou JL, Liu LF, Xin GZ. Fluorous-paired derivatization approach towards highly sensitive and accurate determination of long chain unsaturated fatty acids by liquid chromatography-tandem mass spectrometry. Anal Chim Acta 2020; 1136:187-195. [PMID: 33081943 DOI: 10.1016/j.aca.2020.09.052] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/15/2020] [Accepted: 09/25/2020] [Indexed: 12/11/2022]
Abstract
Long chain unsaturated fatty acids (LCUFAs) are emerging as critical contributors to inflammation and its resolution. Sensitive and accurate measurement of LCUFAs in biological samples is thus of great value in disease diagnosis and prognosis. In this work, a fluorous-derivatization approach for UPLC-MS/MS quantification of LCUFAs was developed by employing a pair of fluorous reagents, namely 3-(perfluorooctyl)-propylamine (PFPA) and 2-(perfluorooctyl)-ethylamine (PFEA). With this method, the LCUFAs in biological samples were perfluoroalkylated with PFPA and specifically retained on a fluorous-phase LC column, which largely reduced matrix interferences-induced quantitation deviation. Moreover, PFEA-labeled LCUFAs standards were introduced as one-to-one internal standards to farthest ensure unbiased results. Application of the proposed method enabled a reliable determination of eight typical LCUFAs with high sensitivity (LLOQ ranged from 30 amol to 6.25 fmol) and low matrix interferences (almost less than 10%). Such a high sensitivity could facilitate the determination of small-volume and low-concentration bio-samples. Further metabolic characterization of these targeted LCUFAs was monitored in OVA-induce asthma mice, requiring only 5 μL serum sample. Our results showed that asthmatic attack led to significant disturbances not only in the concentrations but also in the ratio among these LCUFAs. In view of the favorable advantages in sensitivity and accuracy, the present fluorous-paired derivatization approach will be expected to serve as a new avenue for dissecting the physiological and clinical implications of LCUFAs, thereby shedding light on the management of diseases related to their disturbances.
Collapse
Affiliation(s)
- Jia-Yi Zheng
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China
| | - Ying-Ying Jin
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China
| | - Zi-Qi Shi
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, Jiangsu, China
| | - Jian-Liang Zhou
- Holistic Integrative Pharmacy Institutes, School of Medicine, Hangzhou Normal University, Hangzhou, 311121, China
| | - Li-Fang Liu
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China.
| | - Gui-Zhong Xin
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China.
| |
Collapse
|
8
|
Fragkaki AG, Petropoulou G, Athanasiadou I, Kiousi P, Kioukia‐Fougia N, Archontaki H, Bakeas E, Angelis YS. Determination of anabolic androgenic steroids as imidazole carbamate derivatives in human urine using liquid chromatography–tandem mass spectrometry. J Sep Sci 2020; 43:2154-2161. [DOI: 10.1002/jssc.202000036] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 02/25/2020] [Accepted: 02/26/2020] [Indexed: 12/31/2022]
Affiliation(s)
- Argyro G. Fragkaki
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| | - Georgia Petropoulou
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
- Laboratory of Analytical ChemistryDepartment of ChemistryNational & Kapodistrian University of Athens Athens Greece
| | | | - Polyxeni Kiousi
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| | - Nassia Kioukia‐Fougia
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| | - Helen Archontaki
- Laboratory of Analytical ChemistryDepartment of ChemistryNational & Kapodistrian University of Athens Athens Greece
| | - Evangelos Bakeas
- Laboratory of Analytical ChemistryDepartment of ChemistryNational & Kapodistrian University of Athens Athens Greece
| | - Yiannis S. Angelis
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| |
Collapse
|
9
|
KAWASUE S, SAKAGUCHI Y, YANO E, HAYAMA T, KOGA R, YOSHIDA H, NOHTA H. Fluorous Derivatization Method for Selective Analysis of Curcumin with Liquid Chromatography-Tandem Mass Spectrometry. CHROMATOGRAPHY 2019. [DOI: 10.15583/jpchrom.2019.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
| | | | - Ena YANO
- Faculty of Pharmaceutical Sciences, Fukuoka University
| | | | - Reiko KOGA
- Faculty of Pharmaceutical Sciences, Fukuoka University
| | | | - Hitoshi NOHTA
- Faculty of Pharmaceutical Sciences, Fukuoka University
| |
Collapse
|
10
|
Derivatization for liquid chromatography-electrospray ionization-mass spectrometry analysis of small-molecular weight compounds. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.07.019] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
11
|
Khamis MM, Adamko DJ, El-Aneed A. Mass spectrometric based approaches in urine metabolomics and biomarker discovery. MASS SPECTROMETRY REVIEWS 2017; 36:115-134. [PMID: 25881008 DOI: 10.1002/mas.21455] [Citation(s) in RCA: 196] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2014] [Revised: 10/05/2014] [Accepted: 10/05/2014] [Indexed: 05/25/2023]
Abstract
Urine metabolomics has recently emerged as a prominent field for the discovery of non-invasive biomarkers that can detect subtle metabolic discrepancies in response to a specific disease or therapeutic intervention. Urine, compared to other biofluids, is characterized by its ease of collection, richness in metabolites and its ability to reflect imbalances of all biochemical pathways within the body. Following urine collection for metabolomic analysis, samples must be immediately frozen to quench any biogenic and/or non-biogenic chemical reactions. According to the aim of the experiment; sample preparation can vary from simple procedures such as filtration to more specific extraction protocols such as liquid-liquid extraction. Due to the lack of comprehensive studies on urine metabolome stability, higher storage temperatures (i.e. 4°C) and repetitive freeze-thaw cycles should be avoided. To date, among all analytical techniques, mass spectrometry (MS) provides the best sensitivity, selectivity and identification capabilities to analyze the majority of the metabolite composition in the urine. Combined with the qualitative and quantitative capabilities of MS, and due to the continuous improvements in its related technologies (i.e. ultra high-performance liquid chromatography [UPLC] and hydrophilic interaction liquid chromatography [HILIC]), liquid chromatography (LC)-MS is unequivocally the most utilized and the most informative analytical tool employed in urine metabolomics. Furthermore, differential isotope tagging techniques has provided a solution to ion suppression from urine matrix thus allowing for quantitative analysis. In addition to LC-MS, other MS-based technologies have been utilized in urine metabolomics. These include direct injection (infusion)-MS, capillary electrophoresis-MS and gas chromatography-MS. In this article, the current progresses of different MS-based techniques in exploring the urine metabolome as well as the recent findings in providing potentially diagnostic urinary biomarkers are discussed. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:115-134, 2017.
Collapse
Affiliation(s)
- Mona M Khamis
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Rd, Saskatoon, SK, S7N 5E5, Canada
- Faculty of Pharmacy, Alexandria University, Alexandria, 21521, Egypt
| | - Darryl J Adamko
- Department of Pediatrics, College of Medicine, University of Saskatchewan, 103 Hospital Drive, Saskatoon, SK, Canada
| | - Anas El-Aneed
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Rd, Saskatoon, SK, S7N 5E5, Canada
| |
Collapse
|
12
|
HAYAMA T, TAMASHIMA E, YOSHIDA H, YAMAGUCHI M, NOHTA H. Multi-Perfluoroalkyl Derivatization of Polyamines for Selective Liquid Chromatography-Tandem Mass Spectrometric Analysis Utilizing Fluorous Affinity. CHROMATOGRAPHY 2017. [DOI: 10.15583/jpchrom.2017.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
| | | | | | | | - Hitoshi NOHTA
- Faculty of Pharmaceutical Sciences, Fukuoka University
| |
Collapse
|
13
|
Hayama T, Kiyokawa E, Yoshida H, Imakyure O, Yamaguchi M, Nohta H. Fluorous-assisted metal chelate affinity extraction technique for analysis of protein kinase activity. Talanta 2016; 156-157:1-5. [DOI: 10.1016/j.talanta.2016.04.058] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2016] [Revised: 04/25/2016] [Accepted: 04/26/2016] [Indexed: 02/07/2023]
|
14
|
HAYAMA T. Development of Analytical Methods Utilizing Selectivity of Fluorous Affinity and Their Applications. CHROMATOGRAPHY 2016. [DOI: 10.15583/jpchrom.2015.039] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
15
|
Profiling and relative quantification of phosphatidylethanolamine based on acetone stable isotope derivatization. Anal Chim Acta 2016; 902:142-153. [DOI: 10.1016/j.aca.2015.11.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 10/15/2015] [Accepted: 11/02/2015] [Indexed: 12/15/2022]
|
16
|
Baghdady YZ, Schug KA. Review of in situ derivatization techniques for enhanced bioanalysis using liquid chromatography with mass spectrometry. J Sep Sci 2015; 39:102-14. [DOI: 10.1002/jssc.201501003] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2015] [Revised: 10/02/2015] [Accepted: 10/02/2015] [Indexed: 11/05/2022]
Affiliation(s)
- Yehia Z. Baghdady
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| | - Kevin A. Schug
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| |
Collapse
|
17
|
Direct tandem mass spectrometric analysis of amino acids in plasma using fluorous derivatization and monolithic solid-phase purification. J Pharm Biomed Anal 2015. [DOI: 10.1016/j.jpba.2015.07.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
18
|
Hayama T. [Development of Selective LC Analysis Method for Biogenic and Related Compounds Based on a Fluorous Affinity Technique]. YAKUGAKU ZASSHI 2015; 135:1043-8. [PMID: 26329550 DOI: 10.1248/yakushi.15-00116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A separation-oriented derivatization method combined with LC has been developed for the selective analysis of biogenic and related compounds. In this method, we utilized a specific affinity between perfluoroalkyl-containing compounds, i.e., 'fluorous' compounds (fluorophilicity). Our strategy involves the derivatization of target analytes with perfluoroalkyl reagents, followed by selective retention of the derivatives with a perfluoroalkyl-modified stationary phase LC column. The perfluoroalkylated derivatives are strongly retained on the column owing to their fluorophilicity, whereas non-derivatized species, such as sample matrices, are hardly retained. Therefore, utilizing this derivatization method, target analytes can be determined selectively without interference from matrices. This method has been successfully applied to the LC analysis of some biogenic and related compounds in complex biological samples.
Collapse
|
19
|
Hayama T. [Highly selective analysis of biogenic-related compounds utilizing fluorous chemistry]. YAKUGAKU ZASSHI 2015; 135:205-12. [PMID: 25747214 DOI: 10.1248/yakushi.14-00213-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Perfluoroalkyl-containing compounds are highly fluorous, meaning that they have a remarkable affinity for one another and effectively exclude non-fluorous species. Utilizing this unique property, we have developed a fluorous derivatization with a liquid chromatographic analysis method for highly selective analysis of target analytes. Although most previous methods focused on extremely sensitive detection-oriented derivatization, the fluorous derivatization method involves highly specific separation for analytes. This method includes perfluoroalkylation of analytes with a fluorous reagent, and separation of the derivatives using a perfluoroalkyl-modified stationary phase LC column. The derivatives can be selectively retained on the fluorous-phase LC column, whereas the non-fluorous derivatives are poorly retained under the same separation conditions. The combination of this method with LC-tandem mass spectrometry (MS/MS) is very useful for complex biological sample analysis, because matrix-induced suppression effects, which are a common problem in LC-MS/MS analysis arising from components of a biological endogenous matrix, have not been observed. We have successfully applied this method to precise and accurate LC-MS/MS analysis of some biogenic compounds, such as sialic acids and biogenic amines, in complex biological samples.
Collapse
|
20
|
HAYAMA T, KIYOKAWA E, YOSHIDA H, IMAKYURE O, YAMAGUCHI M, NOHTA H. Selective Extraction of Nucleotides with Fluorous Biphasic System Utilizing Perfluoroalkylamine as an Ion-Pair Reagent. CHROMATOGRAPHY 2015. [DOI: 10.15583/jpchrom.2015.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
| | - Ena KIYOKAWA
- Faculty of Pharmaceutical Sciences, Fukuoka University
| | | | | | | | - Hitoshi NOHTA
- Faculty of Pharmaceutical Sciences, Fukuoka University
| |
Collapse
|
21
|
Sakaguchi Y, Hayama T, Yoshida H, Itoyama M, Todoroki K, Yamaguchi M, Nohta H. Liquid chromatography/tandem mass spectrometry with fluorous derivatization method for selective analysis of sialyl oligosaccharides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:2481-2489. [PMID: 25366395 DOI: 10.1002/rcm.7042] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Revised: 09/02/2014] [Accepted: 09/03/2014] [Indexed: 06/04/2023]
Abstract
RATIONALE A separation-oriented derivatization method using a specific fluorous affinity between perfluoroalkyl-containing compounds was applied to selective liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of sialyl oligosaccharides. The perfluoroalkyl-labeled sialyl oligosaccharides could be selectively retained on an LC column with the perfluoroalkyl-modified stationary phase and effectively distinguished from non-derivatized species. METHODS Sialyl oligosaccharides (3'-sialyllactose, 6'-sialyllactose, sialyllacto-N-tetraose a, sialyllacto-N-tetraose b, sialyllacto-N-tetraose c, and disialyllacto-N-tetraose) were derivatized with 4,4,5,5,6,6,7,7,8,8,9,9,10,10,11,11,11-heptadecafluoroundecylamine via amidation in the presence of 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (condensation reagent). The obtained derivatives were directly injected onto the fluorous LC column without any pretreatments and then detected by positive electrospray ionization MS/MS. RESULTS The method enabled accurate determination of the sialyl oligosaccharides in biological samples such as human urine and human milk, because there was no interference with matrix-induced effects during LC/MS/MS analysis. The limits of detection of the examined sialyl oligosaccharides, defined as signal-to-noise (S/N) = 3, were in the range 0.033-0.13 nM. Accuracy in the range 95.6-108% was achieved, and the precision (relative standard deviation) was within 9.4%. CONCLUSIONS This method enabled highly selective and sensitive analysis of sialyl oligosaccharides, enabling accurate measurement of even their trace amounts in biological matrices. The proposed method may prove to be a powerful tool for the analysis of various sialyl oligosaccharides.
Collapse
Affiliation(s)
- Yohei Sakaguchi
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka, 814-0180, Japan
| | | | | | | | | | | | | |
Collapse
|
22
|
Fluorous affinity-based separation techniques for the analysis of biogenic and related molecules. J Pharm Biomed Anal 2014; 101:151-60. [DOI: 10.1016/j.jpba.2014.04.035] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2014] [Revised: 04/21/2014] [Accepted: 04/23/2014] [Indexed: 01/08/2023]
|
23
|
Qi BL, Liu P, Wang QY, Cai WJ, Yuan BF, Feng YQ. Derivatization for liquid chromatography-mass spectrometry. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.03.013] [Citation(s) in RCA: 155] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Wang D, Zhou X, Wang L, Wang S, Sun XL. Quantification of free sialic acid in human plasma through a robust quinoxalinone derivatization and LC-MS/MS using isotope-labeled standard calibration. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 944:75-81. [PMID: 24291723 DOI: 10.1016/j.jchromb.2013.11.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2013] [Revised: 11/03/2013] [Accepted: 11/07/2013] [Indexed: 10/26/2022]
Abstract
We report an accurate quantification of free sialic acid (SA) in human plasma using LC-MS/MS method with isotope-labeled standard calibration (ILSC) and robust derivatization. Specifically, derivatization of SA with a stable and inexpensive 3,4-diaminotoluene (DAT) provides a stable product of SA with high MS response, proving a convenient and cost-effective LC-MS/MS analysis of free SA. In addition, the use of (13)C3-SA as calibration standard ensured the accuracy for the measurement. This assay used ultra high performance liquid chromatography (UHPLC) for separation of native/labeled SA and IS from matrix interference, and employed mass spectrometry in multiple reaction monitoring (MRM) mode for sensitive and selective detection. We have achieved a lower limit of quantification (LLOQ) of 20ng/mL and a total running time of 4.2min, which is the most sensitive and quick measurement for free SA in biomatrices.
Collapse
Affiliation(s)
- Dan Wang
- Department of Chemistry, Chemical and Biomedical Engineering and Center for Gene Regulation in Health and Disease (GRHD), Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115, United States
| | - Xiang Zhou
- Department of Chemistry, Chemical and Biomedical Engineering and Center for Gene Regulation in Health and Disease (GRHD), Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115, United States
| | - Lin Wang
- School of Pharmaceutical Science, China Medical University, 92 Bei-er Road, Shenyang, Liaoning 110001, China
| | - Sihe Wang
- Department of Clinical Pathology, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, United States
| | - Xue-Long Sun
- Department of Chemistry, Chemical and Biomedical Engineering and Center for Gene Regulation in Health and Disease (GRHD), Cleveland State University, 2121 Euclid Avenue, Cleveland, OH 44115, United States.
| |
Collapse
|
25
|
Ota T, Yasuda M, Iijima R, Yui S, Fukuuchi T, Yamaoka N, Mawatari KI, Kaneko K, Nakagomi K. Development of a fluorescence analysis method for N-acetylneuraminic acid and its oxidized product ADOA. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 932:152-7. [DOI: 10.1016/j.jchromb.2013.06.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2012] [Revised: 06/03/2013] [Accepted: 06/07/2013] [Indexed: 01/17/2023]
|
26
|
Dress-up chiral columns for the enantioseparation of amino acids based on fluorous separation. Anal Bioanal Chem 2013; 405:8121-9. [DOI: 10.1007/s00216-013-7207-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Revised: 06/28/2013] [Accepted: 07/02/2013] [Indexed: 11/28/2022]
|
27
|
Combination of two different stationary phases for on-line pre-concentration and separation of basic drugs by using nano-liquid chromatography. J Chromatogr A 2013; 1285:118-23. [DOI: 10.1016/j.chroma.2013.02.035] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Revised: 02/06/2013] [Accepted: 02/09/2013] [Indexed: 11/20/2022]
|
28
|
Orozco-Solano M, Priego-Capote F, Luque de Castro M. Ultrasound-assisted hydrolysis and chemical derivatization combined to lab-on-valve solid-phase extraction for the determination of sialic acids in human biofluids by μ-liquid chromatography-laser induced fluorescence. Anal Chim Acta 2013; 766:69-76. [DOI: 10.1016/j.aca.2012.12.045] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2012] [Revised: 12/12/2012] [Accepted: 12/23/2012] [Indexed: 10/27/2022]
|
29
|
Hayama T, Sakaguchi Y, Yoshida H, Itoyama M, Todoroki K, Yamaguchi M, Nohta H. Binary Fluorous Alkylation of Biogenic Primary Amines with Perfluorinated Aldehyde Followed by Fluorous Liquid Chromatography–Tandem Mass Spectrometry Analysis. Anal Chem 2012; 84:8407-14. [DOI: 10.1021/ac3020092] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Tadashi Hayama
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka
814-0180, Japan
| | - Yohei Sakaguchi
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka
814-0180, Japan
| | - Hideyuki Yoshida
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka
814-0180, Japan
| | - Miki Itoyama
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka
814-0180, Japan
| | - Kenichiro Todoroki
- Laboratory
of Analytical and
Bio-Analytical Chemistry, Graduate School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga, Shizuoka
422-8526, Japan
| | - Masatoshi Yamaguchi
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka
814-0180, Japan
| | - Hitoshi Nohta
- Faculty of Pharmaceutical Sciences, Fukuoka University, 8-19-1 Nanakuma, Johnan, Fukuoka
814-0180, Japan
| |
Collapse
|
30
|
Abstract
LC with atmospheric pressure ionization MS is essential to a large number of quantitative bioanalyses for a variety of compounds, especially nonvolatile or highly polar compounds. However, in many instances, weak ionization, poor LC retention and instability of certain analytes hinder the development of the LC–MS/MS method. Chemical derivatization has been used for different classes of analytes to improve their ionization efficiency, chromatographic separation and chemical stability. This work presents an overview of chemical derivatization methods that have been applied to the quantitative LC–MS/MS analyses of nine classes of molecules, including aldehydes, amino acids, bisphosphonate drugs, carbohydrates, carboxylic acids, nucleosides and their associated analogs, steroids, thiol-containing compounds and vitamin D metabolites, in biological matrices.
Collapse
|
31
|
Sakaguchi Y, Yoshida H, Hayama T, Itoyama M, Todoroki K, Yamaguchi M, Nohta H. Selective liquid-chromatographic determination of native fluorescent biogenic amines in human urine based on fluorous derivatization. J Chromatogr A 2011; 1218:5581-6. [DOI: 10.1016/j.chroma.2011.05.076] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2011] [Revised: 05/18/2011] [Accepted: 05/21/2011] [Indexed: 11/25/2022]
|
32
|
Sakaguchi Y, Yoshida H, Hayama T, Yoshitake M, Itoyama M, Todoroki K, Yamaguchi M, Nohta H. Fluorous derivatization and fluorous-phase separation for fluorometric determination of naproxen and felbinac in human plasma. J Pharm Biomed Anal 2011; 55:176-80. [DOI: 10.1016/j.jpba.2011.01.011] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2010] [Revised: 12/28/2010] [Accepted: 01/08/2011] [Indexed: 02/03/2023]
|
33
|
Iwasaki Y, Nakano Y, Mochizuki K, Nomoto M, Takahashi Y, Ito R, Saito K, Nakazawa H. A new strategy for ionization enhancement by derivatization for mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:1159-65. [PMID: 21382752 DOI: 10.1016/j.jchromb.2011.02.008] [Citation(s) in RCA: 96] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2010] [Revised: 01/07/2011] [Accepted: 02/07/2011] [Indexed: 11/29/2022]
Abstract
Liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure ionization is drastically different from hitherto available analytical methods used to detect polar analytes. The electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources of MS have contributed to the advancement of LC-MS and LC-MS/MS techniques for the analysis of biological samples. However, one major obstacle is the weak ionization of some analytes in the ESI and APCI techniques. In this review, we introduce high-sensitivity methods using several derivatization reagents for ionization enhancement. We also present an overview of chemical derivatization methods that have been applied to small molecules, such as amino acids and steroids, in biological samples.
Collapse
Affiliation(s)
- Yusuke Iwasaki
- Department of Analytical Chemistry, Faculty of Pharmaceutical Sciences, Hoshi University, 2-4-41 Ebara, Shinagawa-ku, Tokyo 142-8501, Japan
| | | | | | | | | | | | | | | |
Collapse
|