1
|
Zhao Q, Wu ZE, Li B, Li F. Recent advances in metabolism and toxicity of tyrosine kinase inhibitors. Pharmacol Ther 2022; 237:108256. [DOI: 10.1016/j.pharmthera.2022.108256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/20/2022] [Accepted: 07/20/2022] [Indexed: 11/15/2022]
|
2
|
Zhang Y, Li X, Sun Y, Liu X, Wang W, Tian J. Pharmacokinetics of S-epacadostat, an indoleamine 2,3-dioxygenase 1 inhibitor, in dog plasma and identification of its metabolites in vivo and in vitro. Biomed Chromatogr 2021; 35:e5226. [PMID: 34388261 DOI: 10.1002/bmc.5226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 07/30/2021] [Accepted: 08/06/2021] [Indexed: 11/06/2022]
Abstract
S-epacadostat (S-EPA) is an efficient and selective small-molecule inhibitor of indoleamine 2,3-dioxygenase 1. It is an EPA analog with a sulfur atom instead of a nitrogen atom at the furazan C3 position. This study documents the pharmacokinetics of S-EPA in dogs and its metabolic pathway. After an oral administration of 15 mg/kg of S-EPA in dogs, the time to peak concentration was 0.80 h, the mean elimination half-life was 7.3 h, and the absolute bioavailability was 55.8%. Furthermore, we identified S-EPA metabolites in dog plasma and dog liver microsomes by UPLC-Q Exactive Orbitrap HRMS. In dog plasma, we found five metabolites, which came from glucuronidation (M1 and M2), deoxygenation (the amidine M4), glucuronidation of M4 (M3), and desulfonamidation and oxidation of M4 (the carboxylic acid M5). In dog liver microsomes, we identified three major metabolites, namely, the glucuronide conjugate (M6), a mono-oxidation product (M7), and a desulfonamidation and oxidation product (M8). Gut microbiota may cause the differences between in vivo and in vitro oxidation metabolisms. Contrary to EPA, S-EPA did not undergo dealkylation, suggesting that substituting the nitrogen with sulfur affects the metabolism of the adjacent alkyl side chain.
Collapse
Affiliation(s)
- Yumu Zhang
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, China
| | - Xin Li
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, China
| | - Yufei Sun
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, China
| | - Xinghua Liu
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, China
| | - Wenyan Wang
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, China
| | - Jingwei Tian
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong, China
| |
Collapse
|
3
|
Retmana IA, Beijnen JH, Sparidans RW. Chromatographic bioanalytical assays for targeted covalent kinase inhibitors and their metabolites. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1162:122466. [PMID: 33316750 DOI: 10.1016/j.jchromb.2020.122466] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 11/17/2020] [Accepted: 11/19/2020] [Indexed: 02/07/2023]
Abstract
Deriving from targeted kinase inhibitors (TKIs), targeted covalent kinase inhibitors (TCKIs) are a new class of TKIs that are covalently bound to their target residue of kinase receptors. Currently, there are many new TCKIs under clinical development besides afatinib, ibrutinib, osimertinib, neratinib, acalabrutinib, dacomitinib, and zanubrutinib that are already approved by the FDA. Subsequently, there is an increasing demand for bioanalytical methods to qualitatively and quantitively investigate those compounds, leading to a number of papers reporting the development, validation, and use of bioanalytical methods for TCKIs. Most publications describe the technological set up of analytical methods that allow quantification of TCKIs in various biomatrices such as plasma, cerebrospinal fluid, urine, tissue, and liver microsomes. In addition, the identification of metabolites and biotransformation pathways of new TCKIs has gained more interest in recent years. We provide an overview of bioanalytical methods of this new class of TCKIs. The included issues are sample pretreatment, chromatographic separation, detection, and method validation. In the scope of bioanalysis of TCKIs, protein precipitation is mostly applied to treat the biological matrices sample. Liquid chromatographic in reversed-phase mode (RPLC) and mass detection with triple quadrupole (QqQ) are the most often utilized separation and quantitative detection modes, respectively. There may be a possibility of increased use of the high-resolution mass spectrometry (HRMS) for qualitative investigation purposes in the future. We also found that US FDA and EMA guidelines are the most common guidelines employed as validation framework for the bioanalytical methods of TCKIs.
Collapse
Affiliation(s)
- Irene A Retmana
- The Netherlands Cancer Institute, Division of Pharmacology, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands; Utrecht University, Faculty of Science, Department of Pharmaceutical Sciences, Division of Pharmacoepidemiology and Clinical Pharmacology, Universiteitsweg 99, 3584 CG, Utrecht, The Netherlands
| | - Jos H Beijnen
- Utrecht University, Faculty of Science, Department of Pharmaceutical Sciences, Division of Pharmacoepidemiology and Clinical Pharmacology, Universiteitsweg 99, 3584 CG, Utrecht, The Netherlands; The Netherlands Cancer Institute, Department of Pharmacy & Pharmacology, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
| | - Rolf W Sparidans
- Utrecht University, Faculty of Science, Department of Pharmaceutical Sciences, Division of Pharmacology, Universiteitsweg 99, 3584 CG, Utrecht, the Netherlands.
| |
Collapse
|
4
|
Niessen WMA, Hillebrand MJX, Rosing H, Beijnen JH. Tandem mass spectrometry of small-molecule signal transduction inhibitors: Accurate-m/z data to adapt structure proposals of product ions. J Pharm Biomed Anal 2020; 195:113864. [PMID: 33387839 DOI: 10.1016/j.jpba.2020.113864] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 12/17/2020] [Accepted: 12/18/2020] [Indexed: 01/22/2023]
Abstract
Protein kinases inhibitors or, more generally, signal transduction inhibitors (STIs) can be used to treat diseases in which deregulation of the protein kinase activity plays a role, such as in cancer. A wide variety of drugs has been developed and/or is under investigation to act as protein kinase inhibitors, especially in tyrosine kinase inhibition. The bioanalysis of STIs has received considerable attention in the past 20 years. Liquid chromatography-tandem mass spectrometry (LC-MS-MS) in selected-reaction monitoring (SRM) mode is the method-of-choice in such studies. In several of these studies from us and others, structures are proposed for the product ions applied in SRM. A critical review of these proposed structures is presented using accurate-m/z data, which we have now generated with a linear-ion-trap-Orbitrap hybrid mass spectrometer. This led to adaptation and new structural proposals of 18 product ions for 13 STIs. Our investigation endorses the power of accurate-m/z analysis in structure elucidation of product ions in bioanalytical LC-MS-MS studies and for which the SRM mode in tandem-quadrupole instruments is apparently less suitable.
Collapse
Affiliation(s)
- W M A Niessen
- hyphen MassSpec, Margrietstraat 34, 2215 HJ, Voorhout, the Netherlands.
| | - M J X Hillebrand
- Department of Pharmacy & Pharmacology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, the Netherlands
| | - H Rosing
- Department of Pharmacy & Pharmacology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, the Netherlands
| | - J H Beijnen
- Department of Pharmacy & Pharmacology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, the Netherlands
| |
Collapse
|