1
|
Guezou-Philippe A, Dardenne G, Letissier H, Yvinou A, Burdin V, Stindel E, Lefèvre C. Anterior pelvic plane estimation for total hip arthroplasty using a joint ultrasound and statistical shape model based approach. Med Biol Eng Comput 2023; 61:195-204. [PMID: 36342596 DOI: 10.1007/s11517-022-02681-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 09/21/2022] [Indexed: 11/09/2022]
Abstract
Orienting properly the prosthetic cup in total hip arthroplasty is key to ensure the postoperative stability. Several navigation solutions have been developed to assist surgeons in orienting the cup regarding the anterior pelvic plane (APP), defined by both anterior superior iliac spines (ASIS) and the pubic symphysis. However acquiring the APP when the patient is ready for surgery, i.e., mainly in lateral decubitus, is difficult due to the contralateral ASIS being against the operating table. We propose a method to determine the APP from both (1) alternative anatomical landmarks which are easy to acquire with a navigated ultrasound probe and (2) a Statistical Shape Model (SSM) of the pelvis. After creating a pelvic SSM from 40 data, a SSM-based morphometric analysis has been carried out to identify the best anatomical landmarks allowing the easy determination of the APP. The proposed method has then been assessed with both in silico and in vivo experiments on respectively forty synthetic data, and five healthy volunteers. The in silico experiment shows the feasibility to determine the APP with an average error of 4.7∘ by only acquiring the iliac crest, the anterior superior iliac spine, the anterior inferior iliac spine, and the pubic symphysis. The average in vivo error using the ultrasound modality was 7.3∘ with an estimated impact on both the cup anteversion and inclination of 4.0∘ and 1.7∘ respectively. The proposed method shows promising results that could allow the determination of the APP in lateral decubitus with a clinically acceptable impact on the computation of the cup orientation.
Collapse
Affiliation(s)
- Aziliz Guezou-Philippe
- Latim INSERM UMR 1101, Brest, France. .,CHU, Brest, France. .,University of Western Brittany, Brest, France.
| | | | - Hoel Letissier
- Latim INSERM UMR 1101, Brest, France.,CHU, Brest, France.,University of Western Brittany, Brest, France
| | - Agathe Yvinou
- Latim INSERM UMR 1101, Brest, France.,CHU, Brest, France.,University of Western Brittany, Brest, France
| | - Valérie Burdin
- Latim INSERM UMR 1101, Brest, France.,IMT Atlantique, Brest, France
| | - Eric Stindel
- Latim INSERM UMR 1101, Brest, France.,CHU, Brest, France.,University of Western Brittany, Brest, France
| | - Christian Lefèvre
- Latim INSERM UMR 1101, Brest, France.,CHU, Brest, France.,University of Western Brittany, Brest, France
| |
Collapse
|
2
|
Guezou-Philippe A, Dardenne G, Salhi A, Burdin V, Lefevre C, Stindel E. Statistical Shape Modeling to Determine the Anterior Pelvic Plane for Total Hip Arthroplasty. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:1364-1367. [PMID: 33018242 DOI: 10.1109/embc44109.2020.9176588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The anterior pelvic plane (APP) defined by both iliac spines and the pubic symphysis, is essential in total hip arthroplasty (THA) for the orientation of the prosthetic cup. However, the APP is nowadays still difficult to determine in computer assisted orthopedic surgery (CAOS). We propose to use a statistical shape model (SSM) of the pelvis to estimate the APP from ipsilateral anatomical landmarks, more easily accessible during surgery in computer assisted THA with the patient in lateral decubitus position. A SSM of the pelvis has been built from 40 male pelvises. Various ipsilateral anatomical landmarks have been extracted from these data and used to deform the SSM. Fitting the SSM to several combinations of these landmarks, we were able to reconstruct the pelvis with an accuracy between 2.8mm and 4.4mm, and estimate the APP inclination with an angular error between 1.3° and 2.8°, depending on the landmarks fitted. Results are promising and show that the APP could be acquired during the intervention from ipsilateral landmarks only.
Collapse
|
4
|
State of the Art of Ultrasound-Based Registration in Computer Assisted Orthopedic Interventions. COMPUTATIONAL RADIOLOGY FOR ORTHOPAEDIC INTERVENTIONS 2016. [DOI: 10.1007/978-3-319-23482-3_14] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|