1
|
Wang D, Bai Y, Zhou Z, Yao Q, Cao W, Ma Y, Wang C. Electropolymerization of a Carbonyl-Modified Dihydropyrazine Derivative for Aqueous Zinc Batteries with Ultrahigh Cycling Stability. ACS APPLIED MATERIALS & INTERFACES 2024; 16:26121-26129. [PMID: 38728577 DOI: 10.1021/acsami.4c02285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2024]
Abstract
The design of aqueous zinc-ion batteries (ZIBs) that have high specific capacity and long-term stability is essential for future large-scale energy storage systems. Cathode materials with extended π-conjugation and abundant active sites are desirable to enhance the charge storage performance and the cycling stability of the aqueous ZIB. Based on this concept, 6,9-dihydropyrazino[2,3-g]quinoxaline-2,3,7,8(1H,4H)-tetrone was chosen as the monomer to be electropolymerized onto carbon cloth (PDHPQ-Tetrone/CC). When used as the cathode material for aqueous ZIBs, an exceptional cycling life (>20,000 cycles) at a current density of 10 A g-1 was achieved, with the specific capacity maintained at 82.8% and with the Coulombic efficiency at around 100% throughout cycling. At the charge-discharge current density of 0.1 A g-1, the ZIB with PDHPQ-Tetrone/CC achieved a high specific capacity of 248 mAh g-1. Kinetic analyses showed that both surface-capacitive-controlled processes and semi-infinite diffusion-controlled processes contribute to the stored charge. The charge storage mechanism was investigated with ex situ characterizations and involves the redox processes of carbonyl/hydroxyl and amino/imino groups coupled with insertion and extraction of both Zn2+ and H+.
Collapse
Affiliation(s)
- Dan Wang
- College of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi 710021, China
| | - Yuxuan Bai
- College of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi 710021, China
| | - Zixiang Zhou
- College of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi 710021, China
| | - Qi Yao
- College of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi 710021, China
| | - Wei Cao
- Scientific Instrument Center, Shanxi University, Taiyuan 030006, People's Republic of China
| | - Yangmin Ma
- College of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi 710021, China
| | - Chao Wang
- College of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi 710021, China
| |
Collapse
|
2
|
Wang C, Yang Y, Zhou Z, Li Y, Li Y, Hou W, Liu S, Tian Y. Electrodeposited Poly(5-Amino-2-Naphthalenesulfonic Acid-co-o-Aminophenol) as the Electrode Material for Flexible Supercapacitor. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2305994. [PMID: 37821409 DOI: 10.1002/smll.202305994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/28/2023] [Indexed: 10/13/2023]
Abstract
Copolymers of 5-amino-2-naphthalenesulfonic acid (ANS) and o-aminophenol (oAP) are electropolymerized on carbon cloth substrate from aqueous solutions, and the electropolymerization process is investigated using electrochemical quartz-crystal microbalance. The surface of the copolymer (PANS-co-oAP) appears rough and is capable to store charge as the battery-type electrode in 1 m H2 SO4 (102.9 mAh g-1 at 1 A g-1 ) or in 1 m ZnSO4 (79.75 mAh g-1 at 1 A g-1 ) aqueous solutions. Compared with PANS and PoAP, the high specific capacity of the PANS-co-oAP is originated from the increased number of electrochemically active sites and increased diffusion rates of ions. Evidence of amino/imino and hydroxyl/carbonyl groups redox processes and cation insertion and extraction are given by ex situ X-ray photoelectron spectroscopy. When used as the electrode material in the flexible solid-state supercapacitors, the specific capacitance is at 37.9 F g-1 which does not significantly alter with the bending angle. The flexible solid-state supercapacitor shows a specific energy of 5.4 Wh kg-1 and a power density of 250.3 W kg-1 at 0.5 A g-1 , and a high capacitance retention (88.2%) after 3000 cycles at 5 A g-1 is achieved.
Collapse
Affiliation(s)
- Chao Wang
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| | - Yifan Yang
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| | - Zixiang Zhou
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| | - Yihao Li
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| | - Yvpei Li
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| | - Wentong Hou
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| | - Shuling Liu
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| | - Yu Tian
- Department of Chemistry and Chemical Engineering, Shaanxi Collaborative Innovation Center of Industrial Auxiliary Chemistry & Technology, Key Laboratory of Auxiliary Chemistry and Technology for Chemical Industry, Ministry of Education, Key Laboratory of Chemical Additives for China National Light Industry, The Youth Innovation Team of Shaanxi Universities, Shaanxi University of Science and Technology, Xi'an, Shaanxi, 710021, China
| |
Collapse
|
3
|
Cembalo G, Ciriello R, Tesoro C, Guerrieri A, Bianco G, Lelario F, Acquavia MA, Di Capua A. An Amperometric Biosensor Based on a Bilayer of Electrodeposited Graphene Oxide and Co-Crosslinked Tyrosinase for L-Dopa Detection in Untreated Human Plasma. Molecules 2023; 28:5239. [PMID: 37446900 DOI: 10.3390/molecules28135239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 07/03/2023] [Accepted: 07/04/2023] [Indexed: 07/15/2023] Open
Abstract
L-Dopa, a bioactive compound naturally occurring in some Leguminosae plants, is the most effective symptomatic drug treatment for Parkinson's disease. During disease progression, fluctuations in L-DOPA plasma levels occur, causing motor complications. Sensing devices capable of rapidly monitoring drug levels would allow adjusting L-Dopa dosing, improving therapeutic outcomes. A novel amperometric biosensor for L-Dopa detection is described, based on tyrosinase co-crosslinked onto a graphene oxide layer produced through electrodeposition. Careful optimization of the enzyme immobilization procedure permitted to improve the long-term stability while substantially shortening and simplifying the biosensor fabrication. The effectiveness of the immobilization protocol combined with the enhanced performances of electrodeposited graphene oxide allowed to achieve high sensitivity, wide linear range, and a detection limit of 0.84 μM, suitable for L-Dopa detection within its therapeutic window. Interference from endogenous compounds, tested at concentrations levels typically found in drug-treated patients, was not significant. Ascorbic acid exhibited a tyrosinase inhibitory behavior and was therefore rejected from the enzymatic layer by casting an outer Nafion membrane. The proposed device was applied for L-Dopa detection in human plasma, showing good recoveries.
Collapse
Affiliation(s)
- Giuseppa Cembalo
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Rosanna Ciriello
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Carmen Tesoro
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Antonio Guerrieri
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Giuliana Bianco
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Filomena Lelario
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Maria Assunta Acquavia
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Angela Di Capua
- Dipartimento di Scienze, University of Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy
| |
Collapse
|
4
|
A Crosstalk- and Interferent-Free Dual Electrode Amperometric Biosensor for the Simultaneous Determination of Choline and Phosphocholine. SENSORS 2021; 21:s21103545. [PMID: 34069690 PMCID: PMC8160789 DOI: 10.3390/s21103545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 05/14/2021] [Indexed: 11/22/2022]
Abstract
Choline (Ch) and phosphocholine (PCh) levels in tissues are associated to tissue growth and so to carcinogenesis. Till now, only highly sophisticated and expensive techniques like those based on NMR spectroscopy or GC/LC- high resolution mass spectrometry permitted Ch and PCh analysis but very few of them were capable of a simultaneous determination of these analytes. Thus, a never reported before amperometric biosensor for PCh analysis based on choline oxidase and alkaline phosphatase co-immobilized onto a Pt electrode by co-crosslinking has been developed. Coupling the developed biosensor with a parallel sensor but specific to Ch, a crosstalk-free dual electrode biosensor was also developed, permitting the simultaneous determination of Ch and PCh in flow injection analysis. This novel sensing device performed remarkably in terms of sensitivity, linear range, and limit of detection so to exceed in most cases the more complex analytical instrumentations. Further, electrode modification by overoxidized polypyrrole permitted the development of a fouling- and interferent-free dual electrode biosensor which appeared promising for the simultaneous determination of Ch and PCh in a real sample.
Collapse
|
5
|
Ciriello R, Carbone M, Coviello D, Guerrieri A, Salvi A. Improved stability of thin insulating poly(o-aminophenol) films in aqueous solutions through an efficient strategy for electrosynthesis under neutral pH conditions: Electrochemical and XPS investigation. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114183] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
6
|
Guerrieri A, Ciriello R, Crispo F, Bianco G. Detection of choline in biological fluids from patients on haemodialysis by an amperometric biosensor based on a novel anti-interference bilayer. Bioelectrochemistry 2019; 129:135-143. [PMID: 31158798 DOI: 10.1016/j.bioelechem.2019.05.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Accepted: 05/17/2019] [Indexed: 01/19/2023]
Abstract
A new and highly selective amperometric biosensor able to analyse choline in clinical samples from patients suffering from renal diseases and receiving repetitive haemodialysis treatment is described. The proposed biosensor is based on choline oxidase immobilized by co-crosslinking onto a novel anti-fouling and anti-interferent membrane. Between the several polymeric films electrosynthesized on a Pt electrode whose permselective behaviours were here investigated, those based on overoxidized polypyrrole/poly(o-aminophenol) bilayer revealed the most effective in rejecting common interferents usually present in biological fluids. The so realized biosensor showed notably analytical performances, displaying linear choline responses up to 100 μM, a sensitivity of 156 nA mM-1 mm-2 and a limit of detection, calculated at a signal-to-noise ratio equal to 3, of 1 μM; further, the within-a-day coefficients of variation for replicate (n = 3) were 2.7% and 1.2% at 100 μM and 10 μM choline levels, respectively. The remarkable performances and anti-interference behaviour allowed us the use of the proposed biosensor for the selective and fouling-free detection of choline in dialysate coming from patients on haemodialysis and even in their unpretreated human sera. Preliminary results gave choline levels in good agreement with the expected values.
Collapse
Affiliation(s)
- Antonio Guerrieri
- Dipartimento di Scienze, Università degli Studi della Basilicata, Viale dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Rosanna Ciriello
- Dipartimento di Scienze, Università degli Studi della Basilicata, Viale dell'Ateneo Lucano 10, 85100 Potenza, Italy.
| | - Fabiana Crispo
- Dipartimento di Scienze, Università degli Studi della Basilicata, Viale dell'Ateneo Lucano 10, 85100 Potenza, Italy
| | - Giuliana Bianco
- Dipartimento di Scienze, Università degli Studi della Basilicata, Viale dell'Ateneo Lucano 10, 85100 Potenza, Italy
| |
Collapse
|
7
|
Carbone ME, Ciriello R, Moscarelli P, Boraldi F, Bianco G, Guerrieri A, Bochicchio B, Pepe A, Quaglino D, Salvi AM. Interactions between elastin-like peptides and an insulating poly(ortho-aminophenol) membrane investigated by AFM and XPS. Anal Bioanal Chem 2018; 410:4925-4941. [DOI: 10.1007/s00216-018-1142-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2018] [Revised: 04/19/2018] [Accepted: 05/14/2018] [Indexed: 01/04/2023]
|
8
|
Carbone MEE, Castle JE, Ciriello R, Salvi AM, Treacy J, Zhdan P. In Situ Electrochemical-AFM and Cluster-Ion-Profiled XPS Characterization of an Insulating Polymeric Membrane as a Substrate for Immobilizing Biomolecules. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2017; 33:2504-2513. [PMID: 28192989 DOI: 10.1021/acs.langmuir.6b04335] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The electrochemical oxidation of ortho-aminophenol (oAP) by cyclic voltammetry (CV), on platinum substrates in neutral solution, produces a polymeric film (PoAP) that grows to a limiting thickness of about 10 nm. The insulating film has potential use as a bioimmobilizing substrate, with its specificity depending on the orientation of its molecular chains. Prior investigations suggest that the film consists of alternating quinoneimine and oAP units, progressively filling all the platinum sites during the electrosynthesis. This work concerns the evaluation of the growth orientation of PoAP chains, which until now was deduced only from indirect evidence. Atomic force microscopy (AFM) has been used in situ with an electrochemical cell so that PoAP deposition on a specific area can be observed, thus avoiding any surface reorganization during ex situ transport. In parallel with microscopy, XPS experiments have been performed using cluster ion beams to profile this film, which is exceptionally thin, without damage while retaining molecular information.
Collapse
Affiliation(s)
- Maria E E Carbone
- Science Department, University of Basilicata , Viale dell'Ateneo Lucano, 10-Potenza, Italy
| | - James E Castle
- Department of Mechanical Engineering Sciences, University of Surrey , Guildford, Surrey, GU2 7XH, U.K
| | - Rosanna Ciriello
- Science Department, University of Basilicata , Viale dell'Ateneo Lucano, 10-Potenza, Italy
| | - Anna M Salvi
- Science Department, University of Basilicata , Viale dell'Ateneo Lucano, 10-Potenza, Italy
| | - Jon Treacy
- Thermo Fisher Scientific, The Birches Industrial Estate, Imberhorne Lane, East Grinstead, West Sussex RH19 1UB, U.K
| | - Peter Zhdan
- Department of Mechanical Engineering Sciences, University of Surrey , Guildford, Surrey, GU2 7XH, U.K
| |
Collapse
|
9
|
Abidi M, Derbel N, Hkiri R, Sbihi HM, Said H, Morallon E, Besbes-Hentati S. Electrodeposition of 4,4′-di-tert-butylbiphenyl peroxide from the anodic oxidation of p-tert-butylphenol in an alkaline acetonitrile solution. J APPL ELECTROCHEM 2017. [DOI: 10.1007/s10800-016-1041-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
10
|
Carbone ME, Ciriello R, Salvi AM, Castle JE. ToF-SIMS study of stages in the electrochemical growth of insulating poly(o-aminophenol) films. SURF INTERFACE ANAL 2016. [DOI: 10.1002/sia.5968] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- M. E. Carbone
- Department of Science; University of Basilicata; Viale dell'Ateneo Lucano, 10 Potenza Italy
| | - R. Ciriello
- Department of Science; University of Basilicata; Viale dell'Ateneo Lucano, 10 Potenza Italy
| | - A. M. Salvi
- Department of Science; University of Basilicata; Viale dell'Ateneo Lucano, 10 Potenza Italy
| | - J. E. Castle
- Department of Mechanical Engineering Science; University of Surrey; Guildford Surrey GU2 7XH UK
| |
Collapse
|
11
|
XPS, AFM, and electrochemical investigation on the inner composition of insulating poly(o-aminophenol), PoAP, deposited on platinum by CV, as a function of the number of cycles. SURF INTERFACE ANAL 2015. [DOI: 10.1002/sia.5910] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
12
|
Carbone ME, Ciriello R, Granafei S, Guerrieri A, Salvi AM. EQCM and XPS investigations on the redox switching of conducting poly(o-aminophenol) films electrosynthesized onto Pt substrates. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.07.047] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
13
|
Carbone ME, Ciriello R, Granafei S, Guerrieri A, Salvi AM. Electrosynthesis of conducting poly(o-aminophenol) films on Pt substrates: a combined electrochemical and XPS investigation. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2014.08.047] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|