1
|
Hemmerová E, Homola J. Combining plasmonic and electrochemical biosensing methods. Biosens Bioelectron 2024; 251:116098. [PMID: 38359667 DOI: 10.1016/j.bios.2024.116098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 01/29/2024] [Accepted: 01/31/2024] [Indexed: 02/17/2024]
Abstract
The idea of combining electrochemical (EC) and plasmonic biosensor methods was introduced almost thirty years ago and the potential of electrochemical-plasmonic (EC-P) biosensors has been highlighted ever since. Despite that, the use of EC-P biosensors in analytics has been rather limited so far and the search for unique applications of the EC-P method continues. In this paper, we review the advances in the field of EC-P biosensors and discuss the features and benefits they can provide. In addition, we identify the main challenges for the development of EC-P biosensors and the limitations that prevent EC-P biosensors from more widespread use. Finally, we review applications of EC-P biosensors for the investigation and quantification of biomolecules, and for the study of biomolecular and cellular processes.
Collapse
Affiliation(s)
- Erika Hemmerová
- Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 1014/57, 182 51, Prague, Czech Republic
| | - Jiří Homola
- Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 1014/57, 182 51, Prague, Czech Republic.
| |
Collapse
|
2
|
Motshakeri M, Sharma M, Phillips ARJ, Kilmartin PA. Electrochemical Methods for the Analysis of Milk. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:2427-2449. [PMID: 35188762 DOI: 10.1021/acs.jafc.1c06350] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The milk and dairy industries are some of the most profitable sectors in many countries. This business requires close control of product quality and continuous testing to ensure the safety of the consumers. The potential risk of contaminants or degradation products and undesirable chemicals necessitates the use of fast, reliable detection tools to make immediate production decisions. This review covers studies on the application of electrochemical methods to milk (i.e., voltammetric and amperometric) to quantify different analytes, as reported over the last 10 to 15 years. The review covers a wide range of analytes, including allergens, antioxidants, organic compounds, nitrogen- and aldehyde containing compounds, biochemicals, heavy metals, hydrogen peroxide, nitrite, and endocrine disruptors. The review also examines pretreatment procedures applied to milk samples and the use of novel sensor materials. Final perspectives are provided on the future of cost-effective and easy-to-use electrochemical sensors and their advantages over conventional methods.
Collapse
Affiliation(s)
- Mahsa Motshakeri
- Polymer Biointerface Centre, School of Chemical Sciences, University of Auckland, Private Bag 92019, Auckland, New Zealand
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Grafton, Auckland 1023, New Zealand
| | - Anthony R J Phillips
- School of Biological Sciences, University of Auckland, Private Bag, 92019 Auckland, New Zealand
| | - Paul A Kilmartin
- Polymer Biointerface Centre, School of Chemical Sciences, University of Auckland, Private Bag 92019, Auckland, New Zealand
| |
Collapse
|
3
|
Bakhshpour M, Göktürk I, Bereli N, Yılmaz F, Denizli A. Selective Detection of Penicillin G Antibiotic in Milk by Molecularly Imprinted Polymer-Based Plasmonic SPR Sensor. Biomimetics (Basel) 2021; 6:biomimetics6040072. [PMID: 34940015 PMCID: PMC8698653 DOI: 10.3390/biomimetics6040072] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 12/06/2021] [Accepted: 12/10/2021] [Indexed: 11/25/2022] Open
Abstract
Molecularly imprinted polymer-based surface plasmon resonance sensor prepared using silver nanoparticles was designed for the selective recognition of Penicillin G (PEN-G) antibiotic from both aqueous solution and milk sample. PEN-G imprinted sensors (NpMIPs) SPR sensor was fabricated using poly (2-hydroxyethyl methacrylate-N-methacroyl-(L)-cysteine methyl ester)-silver nanoparticles-N-methacryloyl-L-phenylalanine methyl ester polymer by embedding silver nanoparticles (AgNPs) into the polymeric film structure. In addition, a non-imprinted (NpNIPs) SPR sensor was prepared by utilizing the same polymerization recipe without addition of the PEN-G template molecule to evaluate the imprinting effect. FTIR-ATR spectrophotometer, ellipsometer, contact angle measurements were used for the characterization of NpMIPs SPR sensors. The linear concentration range of 0.01–10 ng/mL PEN-G was studied for kinetic analyses. The augmenting effect of AgNPs used to increase the surface plasmon resonance signal response was examined using polymer-based PEN-G imprinted (MIPs) sensor without the addition of AgNPs. The antibiotic amount present in milk chosen as a real sample was measured by spiking PEN-G into the milk. According to the Scatchard, Langmuir, Freundlich and Langmuir–Freundlich adsorption models, the interaction mechanism was estimated to be compatible with the Langmuir model.
Collapse
Affiliation(s)
- Monireh Bakhshpour
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey; (M.B.); (I.G.); (N.B.)
| | - Ilgım Göktürk
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey; (M.B.); (I.G.); (N.B.)
| | - Nilay Bereli
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey; (M.B.); (I.G.); (N.B.)
| | - Fatma Yılmaz
- Department of Chemistry Technology, Bolu Abant Izzet Baysal University, Bolu 14900, Turkey;
| | - Adil Denizli
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey; (M.B.); (I.G.); (N.B.)
- Correspondence:
| |
Collapse
|
4
|
Designing of Nanomaterials-Based Enzymatic Biosensors: Synthesis, Properties, and Applications. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2010012] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Among the many biological entities employed in the development of biosensors, enzymes have attracted the most attention. Nanotechnology has been fostering excellent prospects in the development of enzymatic biosensors, since enzyme immobilization onto conductive nanostructures can improve characteristics that are crucial in biosensor transduction, such as surface-to-volume ratio, signal response, selectivity, sensitivity, conductivity, and biocatalytic activity, among others. These and other advantages of nanomaterial-based enzymatic biosensors are discussed in this work via the compilation of several reports on their applications in different industrial segments. To provide detailed insights into the state of the art of this technology, all the relevant concepts around the topic are discussed, including the properties of enzymes, the mechanisms involved in their immobilization, and the application of different enzyme-derived biosensors and nanomaterials. Finally, there is a discussion around the pressing challenges in this technology, which will be useful for guiding the development of future research in the area.
Collapse
|
5
|
Çimen D, Bereli N, Denizli A. Surface Plasmon Resonance Based on Molecularly Imprinted Polymeric Film for l-Phenylalanine Detection. BIOSENSORS 2021; 11:21. [PMID: 33467753 PMCID: PMC7830203 DOI: 10.3390/bios11010021] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 01/12/2021] [Accepted: 01/13/2021] [Indexed: 05/05/2023]
Abstract
In this study, we designed a simple, rapid, sensitive and selective surface plasmon resonance (SPR) sensor for detection of L-phenylalaine by utilizing molecular imprinting technology. l-phenylalanine imprinted and non-imprinted poly(2-hydroxyethyl methacrylate-methacryloyl-l-phenylalanine) polymeric films were synthesized onto SPR chip surfaces using ultraviolet polymerization. l-phenyalanine imprinted and non-imprinted SPR sensors were characterized by using contact angle, atomic force microscopy and ellipsometry. After characterization studies, kinetic studies were carried out in the concentration range of 5.0-400.0 μM. The limit of detection and quantification were obtained as 0.0085 and 0.0285 μM, respectively. The response time for the test including equilibration, adsorption and desorption was approximately 9 min. The selectivity studies of the l-phenylalanine imprinted SPR sensor was performed in the presence of d-phenylalanine and l-tryptophan. Validation studies were carried out via enzyme-linked immunosorbent analysis technique in order to demonstrate the applicability and superiority of the l-phenylalanine imprinted SPR sensor.
Collapse
Affiliation(s)
| | | | - Adil Denizli
- Department of Chemistry, Hacettepe University, Beytepe, 06800 Ankara, Turkey; (D.Ç.); (N.B.)
| |
Collapse
|
6
|
Garzón V, Bustos RH, G. Pinacho D. Personalized Medicine for Antibiotics: The Role of Nanobiosensors in Therapeutic Drug Monitoring. J Pers Med 2020; 10:E147. [PMID: 32993004 PMCID: PMC7712907 DOI: 10.3390/jpm10040147] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 09/05/2020] [Accepted: 09/07/2020] [Indexed: 01/01/2023] Open
Abstract
Due to the high bacterial resistance to antibiotics (AB), it has become necessary to adjust the dose aimed at personalized medicine by means of therapeutic drug monitoring (TDM). TDM is a fundamental tool for measuring the concentration of drugs that have a limited or highly toxic dose in different body fluids, such as blood, plasma, serum, and urine, among others. Using different techniques that allow for the pharmacokinetic (PK) and pharmacodynamic (PD) analysis of the drug, TDM can reduce the risks inherent in treatment. Among these techniques, nanotechnology focused on biosensors, which are relevant due to their versatility, sensitivity, specificity, and low cost. They provide results in real time, using an element for biological recognition coupled to a signal transducer. This review describes recent advances in the quantification of AB using biosensors with a focus on TDM as a fundamental aspect of personalized medicine.
Collapse
Affiliation(s)
- Vivian Garzón
- PhD Biosciences Program, Universidad de La Sabana, Chía 140013, Colombia;
| | - Rosa-Helena Bustos
- Therapeutical Evidence Group, Clinical Pharmacology, Universidad de La Sabana, Chía 140013, Colombia;
| | - Daniel G. Pinacho
- Therapeutical Evidence Group, Clinical Pharmacology, Universidad de La Sabana, Chía 140013, Colombia;
| |
Collapse
|
7
|
Çimen D, Bereli N, Günaydın S, Denizli A. Detection of cardiac troponin-I by optic biosensors with immobilized anti-cardiac troponin-I monoclonal antibody. Talanta 2020; 219:121259. [PMID: 32887150 DOI: 10.1016/j.talanta.2020.121259] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 05/29/2020] [Accepted: 05/31/2020] [Indexed: 01/05/2023]
Abstract
In this study, it is aimed to determine cardiac troponin I by a surface plasmon resonance biosensor immobilized anti-cardiac troponin I monoclonal antibody. The immobilized anti-cardiac troponin I monoclonal antibody surface plasmon resonance biosensors were characterized with ellipsometry, atomic force microscopy and contact angle analysis. After that, surface plasmon resonance biosensor system was completed to biosensor system to investigate kinetic properties for cardiac tropinin I. The sensing ability of surface plasmon resonance biosensor was investigated with 0.001-8.0 ng/mL concentrations of cardiac tropinin I solutions. The limit of detection and limit of quantification were calculated as 0.00012 ng/mL and 0.00041 ng/mL, respectively. To show the selectivity of surface plasmon resonance biosensor competitive adsorption of cardiac tropinin I, myoglobin, immunoglobulin G and prostate specific antigen were investigated. Surface plasmon resonance biosensor was investigated five times with 0.5 ng/mL concentrations of cardiac tropinin I solution to show reuse of the chip. The results showed that surface plasmon resonance biosensor has high selectivity for cardiac tropinin I. The reproducibility of surface plasmon resonance sensors was investigated both on the same day and on different days for five times. To determine the usability, selectivity and validation studies of surface plasmon resonance biosensors were performed by enzyme-linked immunosorbent assay method.
Collapse
Affiliation(s)
- Duygu Çimen
- Hacettepe University, Department of Chemistry, Beytepe, Ankara, Turkey
| | - Nilay Bereli
- Hacettepe University, Department of Chemistry, Beytepe, Ankara, Turkey
| | - Serdar Günaydın
- Department of Cardiovascular Surgery, Ankara Numune Education Hospital, Ankara, Turkey
| | - Adil Denizli
- Hacettepe University, Department of Chemistry, Beytepe, Ankara, Turkey.
| |
Collapse
|