1
|
Single-Cell Patterning Based on Immunocapture and a Surface Modified Substrate. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8112152] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Micropatterning technology offers powerful methods for biological analyses at the molecular level, enabling the investigation of cell heterogeneities, as well as high throughput detection. We herein propose an approach for single-cell patterning. The substrate was prepared using micro fabrication and surface modification processes, and the patterning template was prepared using bovine serum albumin and streptavidin, which can be employed for the patterning of any biological molecules containing biotin. Subsequent to photolithography, etching, chemical vapor deposition (CVD), and polyethylene glycol (PEG) treatment, the optimized patterns were obtained with high accuracy, strong contrast, and good repeatability, thus providing good foundations for the subsequent single-cell patterning. The surface passivation method was proven effective, preventing unwanted binding of the antibodies and cells. Based on this streptavidin template, the specific binding between the biotinylated antibodies and the antigens expressed on the surface of the cells was enabled, and we successfully achieved single-cell patterning with a single-cell capture rate of 92%. This single-cell array offers an effective method in the investigation of cell heterogeneity and drug screening. Further, these methods can be used in the final step for the screening and enrichment of certain cells, such as circulating tumor cells.
Collapse
|
2
|
Liu L, Wu S, Jing F, Zhou H, Jia C, Li G, Cong H, Jin Q, Zhao J. Bead-based microarray immunoassay for lung cancer biomarkers using quantum dots as labels. Biosens Bioelectron 2016; 80:300-306. [PMID: 26852198 DOI: 10.1016/j.bios.2016.01.084] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Revised: 01/18/2016] [Accepted: 01/29/2016] [Indexed: 01/14/2023]
Abstract
In this study, we developed a multiplex immunoassay system that combines the suspension and planar microarray formats within a single layer of polydimethylsiloxane (PDMS) using soft lithography technology. The suspension format was based on the target proteins forming a sandwich structure between the magnetic beads and the quantum dot (QD) probes through specific antibody-antigen interactions. The planar microarray format was produced by fabricating an array of micro-wells in PDMS. Each micro-well was designed to trap a single microbead and eventually generated a microbead array within the PDMS chamber. The resultant bead-based on-chip assay could be used for simultaneously detecting three lung cancer biomarkers-carcinoembryonic antigen (CEA), fragments of cytokeratin 19 (CYFRA21-1) and neuron-specific enolase (NSE)-in 10 μl of human serum, with a wide linear dynamic range (1.03-111 ng/mL for CEA and CYFRA21-1; 9.26-1000 ng/ml for NSE) and a low detection limit (CEA: 0.19 ng/ml; CYFRA21-1: 0.97 ng/ml; NSE: 0.37 ng/ml; S/N=3). Our micro-well chip does not require complex e-beam lithography or the reactive ion etching process as with existing micro-well systems, which rely on expensive focused ion beam (FIB) milling or optical fiber bundles. Furthermore, the current approach is easy to operate without extra driving equipment such as pumps, and can make parallel detection for multiplexing with rapid binding kinetics, small reagent consumption and low cost. This work has demonstrated the importance of the successful application of on-chip multiplexing sandwich assays for the detection of biomarker proteins.
Collapse
Affiliation(s)
- Lifen Liu
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China
| | - Simin Wu
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China
| | - Fengxiang Jing
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China
| | - Hongbo Zhou
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China
| | - Chunping Jia
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China.
| | - Gang Li
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China
| | - Hui Cong
- Department of Tumor Chemotherapy, The Affiliated Hospital of Nantong University, No. 20 Xisi Road, Nantong, Jiangsu 226001, China.
| | - Qinghui Jin
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China
| | - Jianlong Zhao
- State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai 200050, PR China
| |
Collapse
|
3
|
Chou J, Li LE, Kulla E, Christodoulides N, Floriano PN, McDevitt JT. Effects of sample delivery on analyte capture in porous bead sensors. LAB ON A CHIP 2012; 12:5249-56. [PMID: 23117481 PMCID: PMC3541674 DOI: 10.1039/c2lc40752c] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Sample delivery is a crucial aspect of point-of-care applications where sample volumes need to be low and assay times short, while providing high analytical and clinical sensitivity. In this paper, we explore the influence of the factors surrounding sample delivery on analyte capture in an immunoassay-based sensor array manifold of porous beads resting in individual wells. We model using computational fluid dynamics and a flow-through device containing beads sensitized specifically to C-reactive protein (CRP) to explore the effects of volume of sample, rate of sample delivery, and use of recirculation vs. unilateral delivery on the effectiveness of the capture of CRP on and within the porous bead sensor. Rate of sample delivery lends to the development of a time-dependent, shrinking depletion region around the bead exterior. Our findings reveal that at significantly high rates of delivery, unique to porous bead substrates, capture at the rim of the bead is reaction-limited, while capture in the interior of the bead is transport-limited. While the fluorescence signal results from the aggregate of captured material throughout the bead, multiple kinetic regimes exist within the bead. Further, under constant pressure conditions dictated by the array architecture, we reveal the existence of an optimal flow rate that generates the highest signal, under point-of-care constraints of limited-volume and limited-time. When high sensitivity is needed, recirculation can be implemented to overcome the analyte capture limitations due to volume and time constraints. Computational simulations agree with experimental results performed under similar conditions.
Collapse
Affiliation(s)
- Jie Chou
- Department of Bioengineering, Rice University, Houston, Texas77005, USA
| | | | | | | | | | | |
Collapse
|
5
|
Zhu Q, Trau D. Multiplex detection platform for tumor markers and glucose in serum based on a microfluidic microparticle array. Anal Chim Acta 2012; 751:146-54. [PMID: 23084064 DOI: 10.1016/j.aca.2012.09.007] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2012] [Revised: 08/30/2012] [Accepted: 09/06/2012] [Indexed: 02/03/2023]
Abstract
We present a multiplex detection platform based on a microfluidic microparticle array to detect proteins and glucose in serum simultaneously. Multiplex detection of proteins and glucose was performed using biofunctionalized microparticles arrayed on gel-based microstructures integrated in microfluidics. The microparticles immobilized on these microstructures showed high stability under microfluidic flow conditions. With arrays of antibody-coated microbeads, microfluidic quantitative immunoassays for two protein tumor markers, human chorionic gonadotropin (hCG) and prostate specific antigen (PSA) were performed in serum samples with detection limits bellow the cut-off values for cancer diagnosis. Parallel to the immunoassays, quantitative enzymatic assays for glucose in the physiological concentration range were performed. Multiplex detection was achieved by using a spatially encoded microarray. By patterning antibody-coated microbeads and enzyme-containing microparticles on a novel mixed structure array, we successfully demonstrated simultaneous immunoassays (binding based assay) for proteins and an enzymatic assay (reaction kinetic based assay) for glucose. Our microparticle arrays could be potentially used for the detection of multiple categories of biomolecules (proteins, small metabolites and DNA) for clinical diagnostics and other biological applications.
Collapse
Affiliation(s)
- Qingdi Zhu
- Department of Bioengineering, National University of Singapore, Singapore
| | | |
Collapse
|
6
|
Abstract
In recent years, there has been a growing interest in using porous microbeads such as agarose beads as solid supports to bind target molecules from complex fluid samples. Porous beads have large surface area to volume ratios and high receptor concentrations, and they facilitate relatively high sensitivity detection and multiplexing. Unfortunately, to take full advantage of the porous beads' attributes, long incubation times are needed due to the relatively slow mass transfer of target molecules from the exterior solution into the beads' interior. To accelerate the mass transfer process, we propose a novel assay in which functionalized porous beads are periodically compressed and expanded. Preliminary experiments were carried out to compare the performance of the pulsating beads with that of conventional, nonpulsating beads. These experiments indicate that the pulsating beads significantly accelerate binding rates with minimal increase in nonspecific binding. Thus, pulsing has the potential of significantly reducing assay time.
Collapse
|
7
|
Filipponi L, Sawant PD, Fulga F, Nicolau DV. Microbeads on microposts: an inverted architecture for bead microarrays. Biosens Bioelectron 2008; 24:1850-7. [PMID: 18976898 DOI: 10.1016/j.bios.2008.09.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2008] [Revised: 09/08/2008] [Accepted: 09/11/2008] [Indexed: 12/18/2022]
Abstract
The rapid development of genomics and proteomics requires accelerated improvement of the microarrays density, multiplexing, readout capabilities and cost-effectiveness. The bead arrays are increasingly attractive because of their self-assembly-based fabrication, which alleviates many problems of top-down microfabrication. Here we present a simple, reliable, robust and modular technique for the fabrication of bead microarrays, which combines the directed assembling of beads in microstructures and PDMS-based replica molding. The beads are first self-assembled in pyramidal microwells fabricated by anisotropic etching of silicon substrates, then transferred on the apex of PDMS pyramids that replicate the silicon microstructures. The arrays are chemically and biochemically robust; they are spatially addressable and have the potential for being informationally addressable; and they appear to offer better readout capabilities than the classical microarrays.
Collapse
Affiliation(s)
- Luisa Filipponi
- BioNanoEngineering Labs, Faculty of Engineering and Industrial Science, Swinburne University of Technology, John Street, Hawthorn, Victoria 3122, Australia
| | | | | | | |
Collapse
|
8
|
West J, Becker M, Tombrink S, Manz A. Micro Total Analysis Systems: Latest Achievements. Anal Chem 2008; 80:4403-19. [PMID: 18498178 DOI: 10.1021/ac800680j] [Citation(s) in RCA: 351] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Jonathan West
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| | - Marco Becker
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| | - Sven Tombrink
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| | - Andreas Manz
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| |
Collapse
|