1
|
Makary C, Menhall A, Lahoud P, Yang KR, Park KB, Razukevicius D, Traini T. Bone-to-Implant Contact in Implants with Plasma-Treated Nanostructured Calcium-Incorporated Surface (XPEEDActive) Compared to Non-Plasma-Treated Implants (XPEED): A Human Histologic Study at 4 Weeks. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2331. [PMID: 38793397 PMCID: PMC11123094 DOI: 10.3390/ma17102331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/10/2024] [Accepted: 05/12/2024] [Indexed: 05/26/2024]
Abstract
Titanium implants undergo an aging process through surface hydrocarbon deposition, resulting in decreased wettability and bioactivity. Plasma treatment was shown to significantly reduce surface hydrocarbons, thus improving implant hydrophilicity and enhancing the osseointegration process. This study investigates the effect of plasma surface treatment on bone-to-implant contact (BIC) of implants presenting a nanostructured calcium-incorporated surface (XPEED®). Following a Randomized Controlled Trial (RCT) design, patients undergoing implant surgery in the posterior maxilla received additional plasma-treated (n = 7) or -untreated (n = 5) 3.5 × 8 mm implants that were retrieved after a 4-week healing period for histological examination. Histomorphometric analysis showed that plasma-treated implants exhibited a 38.7% BIC rate compared to 22.4% of untreated implants (p = 0.002), indicating enhanced osseointegration potential. Histological images also revealed increased bone formation and active osteoblastic activity around plasma-treated implants when compared to untreated specimens. The findings suggest that plasma treatment improves surface hydrophilicity and biological response, facilitating early bone formation around titanium implants. This study underscores the importance of surface modifications in optimizing implant integration and supports the use of plasma treatment to enhance osseointegration, thereby improving clinical outcomes in implant dentistry and offering benefits for immediate and early loading protocols, particularly in soft bone conditions.
Collapse
Affiliation(s)
- Christian Makary
- Oral Surgery Department, Saint Joseph University, Beirut P.O. Box 1104-2020, Lebanon; (C.M.); (A.M.); (P.L.)
| | - Abdallah Menhall
- Oral Surgery Department, Saint Joseph University, Beirut P.O. Box 1104-2020, Lebanon; (C.M.); (A.M.); (P.L.)
| | - Pierre Lahoud
- Oral Surgery Department, Saint Joseph University, Beirut P.O. Box 1104-2020, Lebanon; (C.M.); (A.M.); (P.L.)
| | - Kyung Ran Yang
- Daegu Mir Dental Hospital, Daegu 41934, Republic of Korea;
| | - Kwang Bum Park
- MegaGen Implant Co., Ltd., Daegu 42921, Republic of Korea;
| | - Dainius Razukevicius
- Faculty of Odontology, Lithuanian University of Health Sciences, LT-50161 Kaunas, Lithuania;
| | - Tonino Traini
- Department of Innovative Technologies in Medicine & Dentistry, University “G. d’Annunzio” of Chieti Pescara, 66100 Chieti, Italy
| |
Collapse
|
2
|
de Iure D, Conti A, Galante A, Spadone S, Hilschenz I, Caulo M, Sensi S, Del Gratta C, Della Penna S. Analyzing the sensitivity of quantitative 3D MRI of longitudinal relaxation at very low field in Gd-doped phantoms. PLoS One 2023; 18:e0285391. [PMID: 37146058 PMCID: PMC10162526 DOI: 10.1371/journal.pone.0285391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 04/20/2023] [Indexed: 05/07/2023] Open
Abstract
PURPOSE Recently, new MRI systems working at magnetic field below 10 mT (Very and Ultra Low Field regime) have been developed, showing improved T1-contrast in projected 2D maps (i.e. images without slice selection). Moving from projected 2D to 3D maps is not trivial due to the low SNR of such devices. This work aimed to demonstrate the ability and the sensitivity of a VLF-MRI scanner operating at 8.9 mT in quantitatively obtaining 3D longitudinal relaxation rate (R1) maps and distinguishing between voxels intensities. We used phantoms consisting of vessels doped with different Gadolinium (Gd)-based Contrast Agent (CA) concentrations, providing a set of various R1 values. As CA, we used a commercial compound (MultiHance®, gadobenate dimeglumine) routinely used in clinical MRI. METHODS 3D R1 maps and T1-weighted MR images were analysed to identify each vessel. R1 maps were further processed by an automatic clustering analysis to evaluate the sensitivity at the single-voxel level. Results obtained at 8.9 mT were compared with commercial scanners operating at 0.2 T, 1.5 T, and 3 T. RESULTS VLF R1 maps offered a higher sensitivity in distinguishing the different CA concentrations and an improved contrast compared to higher fields. Moreover, the high sensitivity of 3D quantitative VLF-MRI allowed an effective clustering of the 3D map values, assessing their reliability at the single voxel level. Conversely, in all fields, T1-weighted images were less reliable, even at higher CA concentrations. CONCLUSION In summary, with few excitations and an isotropic voxel size of 3 mm, VLF-MRI 3D quantitative mapping showed a sensitivity better than 2.7 s-1 corresponding to a concentration difference of 0.17 mM of MultiHance in copper sulfate doped water, and improved contrast compared to higher fields. Based on these results, future studies should characterize R1 contrast at VLF, also with other CA, in the living tissues.
Collapse
Affiliation(s)
- Danilo de Iure
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
| | - Allegra Conti
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
- Medical Physics Section, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy
| | - Angelo Galante
- MESVA, Department of Life, Health & Environmental Sciences, L'Aquila University, L'Aquila, AQ, Italy
- INFN, National Institute of Nuclear Physics, Gran Sasso National Laboratories, Assergi, L'Aquila, Italy
- CNR, SPIN-CNR Institute, Dept. of Physical and Chemical Sciences, L'Aquila, Italy
| | - Sara Spadone
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
| | - Ingo Hilschenz
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
| | - Massimo Caulo
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
- Institute for Advanced Biomedical Technologies (ITAB), G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
| | - Stefano Sensi
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
- Institute for Advanced Biomedical Technologies (ITAB), G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
| | - Cosimo Del Gratta
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
- Institute for Advanced Biomedical Technologies (ITAB), G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
| | - Stefania Della Penna
- Department of Neuroscience, Imaging and Clinical Sciences, G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
- Institute for Advanced Biomedical Technologies (ITAB), G. D'Annunzio University of Chieti and Pescara, Chieti, CH, Italy
| |
Collapse
|
3
|
Effect of Surface Tooling Techniques of Medical Titanium Implants on Bacterial Biofilm Formation In Vitro. MATERIALS 2022; 15:ma15093228. [PMID: 35591562 PMCID: PMC9103970 DOI: 10.3390/ma15093228] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 04/12/2022] [Accepted: 04/25/2022] [Indexed: 02/04/2023]
Abstract
The aim of this study was to assess the biofilm formation of Streptococcus mutans, Staphylococcus aureus, Enterococcus faecalis, and Escherichia coli on titanium implants with CAD-CAM tooling techniques. Twenty specimens of titanium were studied: Titanium grade 2 tooled with a Planmeca CAD-CAM milling device (TiGrade 2), Ti6Al4V grade 5 as it comes from CAD-DMLS device (computer aided design-direct metal laser sintering device) (TiGrade 5), Ti6Al4V grade 23 as it comes from a CAD-CAM milling device (TiGrade 23), and CAD-DMLS TiGrade 5 polished with an abrasive disc (TiGrade 5 polished). Bacterial adhesion on the implants was completed with and without saliva treatment to mimic both extraoral and intraoral surgical methods of implant placement. Five specimens/implant types were used in the bacterial adhesion experiments. Autoclaved implant specimens were placed in petri plates and immersed in saliva solution for 30 min at room temperature and then washed 3×with 1 ×PBS. Bacterial suspensions of each strain were made and added to the specimens after saliva treatment. Biofilm was allowed to form for 24 h at 37 °C and the adhered bacteria was calculated. Tooling techniques had an insignificant effect on the bacterial adhesion by all the bacterial strains studied. However, there was a significant difference in biofilm formation between the saliva-treated and non-saliva-treated implants. Saliva contamination enhanced S. mutans, S. aureus, and E. faecalis adhesion in all material types studied. S. aureus was found to be the most adherent strain in the saliva-treated group, whereas E. coli was the most adherent strain in the non-saliva-treated group. In conclusion, CAD-CAM tooling techniques have little effect on bacterial adhesion. Saliva coating enhances the biofilm formation; therefore, saliva contamination of the implant must be minimized during implant placement. Further extensive studies are needed to evaluate the effects of surface treatments of the titanium implant on soft tissue response and to prevent the factors causing implant infection and failure.
Collapse
|
4
|
Accuracy and Reliability of CBCT Compared to Clinical Probing in Detection of Trifurcation Defects: An In Vivo Study. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5805776. [PMID: 35463972 PMCID: PMC9023149 DOI: 10.1155/2022/5805776] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 02/04/2022] [Accepted: 03/17/2022] [Indexed: 11/26/2022]
Abstract
Background Furcation defects are areas of pathological bone resorption in multirooted teeth. The aim of the study was to compare the measurements of trifurcation bone loss, measured using CBCT, versus clinical measurements in order to evaluate the efficacy of CBCT as an adjunctive diagnostic tool. Material and Methods. The included patients had both CBCT scans for maxillary molars and completed periodontal charts. Clinical examination consisted of probing and detection of vertical and horizontal furcation defects. These were measured and recorded. CBCT measurements were then evaluated using the linear measuring tool in Carestream imaging software (Carestream, Rochester, USA) and iCAT (Imaging Sciences, Hatfield, USA). These measurements of the CBCT images were then documented and compared to clinical findings. The two examiners were blinded to each other's measurements. Results The most common tooth with a detected furcation defect was tooth #2 (31.7%), followed by tooth #15 (26.8%) and #3 (21.9%). The least common tooth with a detected furcation defect was #14 (19.5%). The mean values of buccal furcation for clinical and CBCT measurements were 3.01 mm and 2.6 mm, respectively. The measurements of mesial furcation were 2.5 mm and 2.2 mm for CBCT. The distal measurement of clinical examination was 2.7 mm and for CBCT was 2.44 mm. Conclusion CBCT can be used as an adjunct to clinical furcation measurements and adds useful diagnostic information to assess trifurcation defects. In addition, CBCT limited field of view (FOV) can provide relatively high-resolution images at a reduced dose that is comparable to two-dimensional imaging.
Collapse
|
5
|
Sant’Anna HR, Casati MZ, Mussi MC, Cirano FR, Pimentel SP, Ribeiro FV, Corrêa MG. Peri-Implant Repair Using a Modified Implant Macrogeometry in Diabetic Rats: Biomechanical and Molecular Analyses of Bone-Related Markers. MATERIALS 2022; 15:ma15062317. [PMID: 35329768 PMCID: PMC8953263 DOI: 10.3390/ma15062317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 03/08/2022] [Accepted: 03/11/2022] [Indexed: 02/01/2023]
Abstract
DM has a high prevalence worldwide and exerts a negative influence on bone repair around dental implants. Modifications of the microgeometry of implants have been related to positive results in bone repair. This study assessed, for the first time, the influence of an implant with modified macrodesign based on the presence of a healing chamber in the pattern of peri-implant repair under diabetic conditions. Thirty Wistar rats were assigned to receive one titanium implant in each tibia (Control Implant (conventional macrogeometry) or Test Implant (modified macrogeometry)) according to the following groups: Non-DM + Control Implant; Non-DM + Test Implant; DM + Control Implant; DM + Test Implant. One month from the surgeries, the implants were removed for counter-torque, and the bone tissue surrounding the implants was stored for the mRNA quantification of bone-related markers. Implants located on DM animals presented lower counter-torque values in comparison with Non-DM ones, independently of macrodesign (p < 0.05). Besides, higher biomechanical retention levels were observed in implants with modified macrogeometry than in the controls in both Non-DM and DM groups (p < 0.05). Moreover, the modified macrogeometry upregulated OPN mRNA in comparison with the control group in Non-DM and DM rats (p < 0.05). Peri-implant bone repair may profit from the use of implants with modified macrogeometry in the presence of diabetes mellitus, as they offer higher biomechanical retention and positive modulation of important bone markers in peri-implant bone tissue.
Collapse
|
6
|
Covariates Relating to Implant Failure and Marginal Bone Loss of a Novel Triangular Neck-Implant Placed by Post-Graduate Students: A 1-Year Prospective Cohort Study. MATERIALS 2022; 15:ma15061987. [PMID: 35329438 PMCID: PMC8952199 DOI: 10.3390/ma15061987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 02/28/2022] [Accepted: 03/04/2022] [Indexed: 02/01/2023]
Abstract
(1) Background: Most of the clinical literature dealing with dental implants has been issued by experienced teams working either in university settings or in private practice. The purpose of this study was to identify contributing covariates to implant failure and marginal bone loss (MBL) at the 1-year follow-up of a novel triangular-neck implant design when placed by inexperienced post-graduate students. (2) Methods: A prospective cohort study was conducted on study participants eligible for implant placement at the UIC (International University of Catalonia), Barcelona, Spain. Implant failure rate and contributors to implant failure and MBL were investigated among 24 implant and patient variables. (3) Results: One hundred and twenty implants (V3, MIS) were placed and rehabilitated by the students. The mean insertion torque was 37.1 Ncm. Survival and success rates were 97.5% and 96.7%, respectively. Implants placed in patients with smoking habits displayed a tendency of higher failure risk (OR = 5.31, p = 0.17) when compared to non-smokers. The mean (SD) MBL was 0.51 (0.44) mm. Gender significantly affected the MBL (p = 0.020). Bleeding on probing (BoP) on the buccal sites proved to be a good predictor of proximal MBL (p = 0.030). (4) Conclusions: The survival and success rates of the V3 triangular-neck implant placed by inexperienced post-graduate students at the 1-year follow-up were high and similar to the ones published in the literature by experienced teams on other implants.
Collapse
|
7
|
Al-Dhamari I, Helal R, Morozova O, Abdelaziz T, Jacob R, Paulus D, Waldeck S. Automatic intra-subject registration and fusion of multimodal cochlea 3D clinical images. PLoS One 2022; 17:e0264449. [PMID: 35235600 PMCID: PMC8890738 DOI: 10.1371/journal.pone.0264449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 02/11/2022] [Indexed: 11/18/2022] Open
Abstract
Background
The postoperative imaging assessment of Cochlear Implant (CI) patients is imperative. The main obstacle is that Magnetic Resonance imaging (MR) is contraindicated or hindered by significant artefacts in most cases with CIs. This study describes an automatic cochlear image registration and fusion method that aims to help radiologists and surgeons to process pre-and postoperative 3D multimodal imaging studies in cochlear implant (CI) patients.
Methods and findings
We propose a new registration method, Automatic Cochlea Image Registration (ACIR-v3), which uses a stochastic quasi-Newton optimiser with a mutual information metric to find 3D rigid transform parameters for registration of preoperative and postoperative CI imaging. The method was tested against a clinical cochlear imaging dataset that contains 131 multimodal 3D imaging studies of 41 CI patients with preoperative and postoperative images. The preoperative images were MR, Multidetector Computed Tomography (MDCT) or Cone Beam Computed Tomography (CBCT) while the postoperative were CBCT. The average root mean squared error of ACIR-v3 method was 0.41 mm with a standard deviation of 0.39 mm. The results were evaluated quantitatively using the mean squared error of two 3D landmarks located manually by two neuroradiology experts in each image and compared to other previously known registration methods, e.g. Fast Preconditioner Stochastic Gradient Descent, in terms of accuracy and speed.
Conclusions
Our method, ACIR-v3, produces high resolution images in the postoperative stage and allows for visualisation of the accurate anatomical details of the MRI with the absence of significant metallic artefacts. The method is implemented as an open-source plugin for 3D Slicer tool.
Collapse
Affiliation(s)
| | - Rania Helal
- Radiodiagnosis Dept., Ain Shams University, Cairo, Egypt
| | - Olesia Morozova
- Computer Vision Department, Koblenz University, Koblenz, Germany
| | | | | | - Dietrich Paulus
- Computer Vision Department, Koblenz University, Koblenz, Germany
| | - Stephan Waldeck
- Interventional Radiology and Neuroradiology Dept., Military Hospital Koblenz, Koblenz, Germany
| |
Collapse
|
8
|
Maximal Bite Force Measured via Digital Bite Force Transducer in Subjects with or without Dental Implants—A Pilot Study. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12031544] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
The aims of the current study were as following: (1) to evaluate the maximal bite forces in patients with dental implants versus patients without dental implants, as measured by a digital bite force transducer (GM10); (2) to evaluate the influences of sex, age, and sleep/awake bruxism on the maximal bite forces of the two groups. Forty patients recruited to the study were divided into two groups: test group (“implant”) if they had one or more posterior restored implants and control group (“no-implant”) without the presence of posterior dental implants. A digital bite fork (GM10) was used to measure the bite forces from three posterior occluding pairs in all participants. Differences in the mean values between the test and control groups and between different sexes were evaluated using one-way and two-way ANOVA tests. A cross-tabulation analysis was conducted to identify a trend line between the groups. There was no significant difference in the maximal bite force between the test and control groups (p = 0.422), but the cross-tabulation analysis revealed a clear trend of a stronger representation of the “no-implant” group at higher occlusal forces. A significant difference was detected between the maximal biting forces of male and female subjects (p = 0.030 in the implant group, p = 0.010 in the no-implant group), regardless of the experimental group. The presence of bruxism and clenching did not influence the bite force values (p = 0.953), and a significant difference was not found between the age groups (p = 0.393). Within the limitations of this study, it may be assumed that there was no significant difference between the maximal bite forces between patients with and without dental implants but that there was a trend line implicating a stronger representation of the “no-implant” group at higher forces. In addition, the results revealed a significant sex-related difference in the maximal occlusal force. Further studies with larger sample sizes are warranted.
Collapse
|
9
|
Kawai MY, Ozasa R, Ishimoto T, Nakano T, Yamamoto H, Kashiwagi M, Yamanaka S, Nakao K, Maruyama H, Bessho K, Ohura K. Periodontal Tissue as a Biomaterial for Hard-Tissue Regeneration following bmp-2 Gene Transfer. MATERIALS 2022; 15:ma15030993. [PMID: 35160948 PMCID: PMC8840059 DOI: 10.3390/ma15030993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 01/15/2022] [Accepted: 01/20/2022] [Indexed: 01/25/2023]
Abstract
The application of periodontal tissue in regenerative medicine has gained increasing interest since it has a high potential to induce hard-tissue regeneration, and is easy to handle and graft to other areas of the oral cavity or tissues. Additionally, bone morphogenetic protein-2 (BMP-2) has a high potential to induce the differentiation of mesenchymal stem cells into osteogenic cells. We previously developed a system for a gene transfer to the periodontal tissues in animal models. In this study, we aimed to reveal the potential and efficiency of periodontal tissue as a biomaterial for hard-tissue regeneration following a bmp-2 gene transfer. A non-viral expression vector carrying bmp-2 was injected into the palate of the periodontal tissues of Wistar rats, followed by electroporation. The periodontal tissues were analyzed through bone morphometric analyses, including mineral apposition rate (MAR) determination and collagen micro-arrangement, which is a bone quality parameter, before and after a gene transfer. The MAR was significantly higher 3-6 d after the gene transfer than that before the gene transfer. Collagen orientation was normally maintained even after the bmp-2 gene transfer, suggesting that the bmp-2 gene transfer has no adverse effects on bone quality. Our results suggest that periodontal tissue electroporated with bmp-2 could be a novel biomaterial candidate for hard-tissue regeneration therapy.
Collapse
Affiliation(s)
- Mariko Yamamoto Kawai
- Department of Welfare, Kansai Women’s College, Osaka 582-0026, Japan
- Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan; (H.Y.); (M.K.); (S.Y.); (K.N.); (K.B.)
- Correspondence: ; Tel.: +81-72-977-6561; Fax: +81-72-977-9564
| | - Ryosuke Ozasa
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, Osaka 565-0871, Japan; (R.O.); (T.I.); (T.N.)
| | - Takuya Ishimoto
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, Osaka 565-0871, Japan; (R.O.); (T.I.); (T.N.)
- Center for Aluminum and Advanced Materials Research and International Collaboration, School of Sustainable Design, University of Toyama, Toyama 930-8555, Japan
| | - Takayoshi Nakano
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, Osaka 565-0871, Japan; (R.O.); (T.I.); (T.N.)
| | - Hiromitsu Yamamoto
- Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan; (H.Y.); (M.K.); (S.Y.); (K.N.); (K.B.)
| | - Marina Kashiwagi
- Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan; (H.Y.); (M.K.); (S.Y.); (K.N.); (K.B.)
| | - Shigeki Yamanaka
- Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan; (H.Y.); (M.K.); (S.Y.); (K.N.); (K.B.)
| | - Kazumasa Nakao
- Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan; (H.Y.); (M.K.); (S.Y.); (K.N.); (K.B.)
| | - Hiroki Maruyama
- Department of Clinical Nephroscience, Graduate School of Medicine and Dental Sciences, Niigata University, Niigata 951-8501, Japan;
| | - Kazuhisa Bessho
- Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Kyoto University, Kyoto 606-8507, Japan; (H.Y.); (M.K.); (S.Y.); (K.N.); (K.B.)
| | - Kiyoshi Ohura
- Department of Nursing, Taisei Gakuin University, Osaka 587-8555, Japan;
| |
Collapse
|
10
|
Shen YW, Tsai YS, Hsu JT, Shie MY, Huang HL, Fuh LJ. Biomechanical Analyses of Porous Designs of 3D-Printed Titanium Implant for Mandibular Segmental Osteotomy Defects. MATERIALS (BASEL, SWITZERLAND) 2022; 15:576. [PMID: 35057294 PMCID: PMC8779878 DOI: 10.3390/ma15020576] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 01/04/2022] [Accepted: 01/11/2022] [Indexed: 01/15/2023]
Abstract
Clinically, a reconstruction plate can be used for the facial repair of patients with mandibular segmental defects, but it cannot restore their chewing function. The main purpose of this research is to design a new three-dimensionally (3D) printed porous titanium mandibular implant with both facial restoration and oral chewing function reconstruction. Its biomechanical properties were examined using both finite element analysis (FEA) and in vitro experiments. Cone beam computed tomography images of the mandible of a patient with oral cancer were selected as a reference to create 3D computational models of the bone and of the 3D-printed porous implant. The pores of the porous implant were circles or hexagons of 1 or 2 mm in size. A nonporous implant was fabricated as a control model. For the FEA, two chewing modes, namely right unilateral molar clench and right group function, were set as loading conditions. Regarding the boundary condition, the displacement of both condyles was fixed in all directions. For the in vitro experiments, an occlusal force (100 N) was applied to the abutment of the 3D-printed mandibular implants with and without porous designs as the loading condition. The porous mandibular implants withstood higher stress and strain than the nonporous mandibular implant, but all stress values were lower than the yield strength of Ti-6Al-4V (800 MPa). The strain value of the bone surrounding the mandibular implant was affected not only by the shape and size of the pores but also by the chewing mode. According to Frost's mechanostat theory of bone, higher bone strain under the porous implants might help maintain or improve bone quality and bone strength. The findings of this study serve as a biomechanical reference for the design of 3D-printed titanium mandibular implants and require confirmation through clinical investigations.
Collapse
Affiliation(s)
- Yen-Wen Shen
- School of Dentistry, China Medical University, Taichung 404, Taiwan; (Y.-W.S.); (Y.-S.T.); (J.-T.H.); (M.-Y.S.)
| | - Yuen-Shan Tsai
- School of Dentistry, China Medical University, Taichung 404, Taiwan; (Y.-W.S.); (Y.-S.T.); (J.-T.H.); (M.-Y.S.)
| | - Jui-Ting Hsu
- School of Dentistry, China Medical University, Taichung 404, Taiwan; (Y.-W.S.); (Y.-S.T.); (J.-T.H.); (M.-Y.S.)
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan
| | - Ming-You Shie
- School of Dentistry, China Medical University, Taichung 404, Taiwan; (Y.-W.S.); (Y.-S.T.); (J.-T.H.); (M.-Y.S.)
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan
- x-Dimension Center for Medical Research and Translation, China Medical University Hospital, Taichung 404, Taiwan
| | - Heng-Li Huang
- School of Dentistry, China Medical University, Taichung 404, Taiwan; (Y.-W.S.); (Y.-S.T.); (J.-T.H.); (M.-Y.S.)
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan
| | - Lih-Jyh Fuh
- School of Dentistry, China Medical University, Taichung 404, Taiwan; (Y.-W.S.); (Y.-S.T.); (J.-T.H.); (M.-Y.S.)
| |
Collapse
|
11
|
Development of a Computational Tool for the Estimation of Alveolar Bone Loss in Oral Radiographic Images. COMPUTATION 2022. [DOI: 10.3390/computation10010008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The present study evaluated a newly developed computational tool (CT) to assess the alveolar bone space and the alveolar crest angle and compares it to dentist assessment (GT). The novel tool consisted of a set of processes initiated with image enhancement, points localization, and angle and area calculations. In total, we analyzed 148 sites in 39 radiographic images, and among these, 42 sites were selected and divided into two groups of non-periodontitis and periodontitis. The alveolar space area (ASA) and alveolar crest angle (ACA) were estimated. The agreement between the computer software and the ground truth was analyzed using the Bland–Altman plot. The sensitivity and specificity of the computer tool were measured using the ROC curve. The Bland–Altman plot showed an agreement between the ground truth and the computational tool in all of the parameters assessed. The ROC curve showed 100% sensitivity and 100% specificity for 12.67 mm of the alveolar space area. The maximum percentage of sensitivity and specificity were 80.95% for 13.63 degrees of the alveolar crest angle. Computer tool assessment provides accurate disease severity and treatment monitoring for evaluating the alveolar space area (ASA) and the alveolar crest angle (ACA).
Collapse
|
12
|
Tosco V, Monterubbianesi R, Furlani M, Giuliani A, Putignano A, Orsini G. Micro-computed tomography for assessing the internal and external voids of bulk-fill composite restorations: A technical report. Imaging Sci Dent 2022; 52:303-308. [PMID: 36238708 PMCID: PMC9530296 DOI: 10.5624/isd.20220007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 04/13/2022] [Accepted: 04/27/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose Materials and Methods Results Conclusion
Collapse
Affiliation(s)
- Vincenzo Tosco
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Riccardo Monterubbianesi
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Michele Furlani
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Alessandra Giuliani
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Angelo Putignano
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Giovanna Orsini
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| |
Collapse
|
13
|
Geometric Reproducibility of Three-Dimensional Oral Implant Planning Based on Magnetic Resonance Imaging and Cone-Beam Computed Tomography. J Clin Med 2021; 10:jcm10235546. [PMID: 34884244 PMCID: PMC8658654 DOI: 10.3390/jcm10235546] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 11/22/2021] [Accepted: 11/24/2021] [Indexed: 12/04/2022] Open
Abstract
This study aimed to investigate the geometric reproducibility of three-dimensional (3D) implant planning based on magnetic resonance imaging (MRI) and cone-beam computed tomography (CBCT). Four raters used a backward-planning approach based on CBCT imaging and standard software to position 41 implants in 27 patients. Implant planning was repeated, and the first and second plans were analyzed for geometric differences regarding implant tip, entry-level, and axis. The procedure was then repeated for MRI data of the same patients. Thus, 656 implant plans were available for analysis of intra-rater reproducibility. For both imaging modalities, the second-round 3D implant plans were re-evaluated regarding inter-rater reproducibility. Differences between the modalities were analyzed using paired t-tests. Intra- and inter-rater reproducibility were higher for CBCT than for MRI. Regarding intra-rater deviations, mean values for MRI were 1.7 ± 1.1 mm/1.5 ± 1.1 mm/5.5 ± 4.2° at implant tip/entry-level/axis. For CBCT, corresponding values were 1.3 ± 0.8 mm/1 ± 0.6 mm/4.5 ± 3.1°. Inter-rater comparisons revealed mean values of 2.2 ± 1.3 mm/1.7 ± 1 mm/7.5 ± 4.9° for MRI, and 1.7 ± 1 mm/1.2 ± 0.7 mm/6 ± 3.7° for CBCT. CBCT-based implant planning was more reproducible than MRI. Nevertheless, more research is needed to increase planning reproducibility—for both modalities—thereby standardizing 3D implant planning.
Collapse
|
14
|
Andreozzi P, Simó C, Moretti P, Porcel JM, Lüdtke TU, Ramirez MDLA, Tamberi L, Marradi M, Amenitsch H, Llop J, Ortore MG, Moya SE. Novel Core-Shell Polyamine Phosphate Nanoparticles Self-Assembled from PEGylated Poly(allylamine hydrochloride) with Low Toxicity and Increased In Vivo Circulation Time. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2102211. [PMID: 34278713 DOI: 10.1002/smll.202102211] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 05/11/2021] [Indexed: 06/13/2023]
Abstract
An approach for reducing toxicity and enhancing therapeutic potential of supramolecular polyamine phosphate nanoparticles (PANs) through PEGylation of polyamines before their assembly into nanoparticles is presented here. It is shown that the number of polyethylene glycol (PEG) chains for polyamine largely influence physico-chemical properties of PANs and their biological endpoints. Poly(allylamine hydrochloride) (PAH) are functionalized through carbodiimide chemistry with three ratios of PEG molecules per PAH chain: 0.1, 1, and 10. PEGylated PAH is then assembled into PANs by exposing the polymer to phosphate buffer solution. PANs decrease size and surface charge with increasing PEG ratios as evidenced by dynamic light scattering and zeta potential measurements, with the ten PEG/PAH ratio PANs having practically zero charge. Small angle X-ray scattering (SAXS) proves that PEG chains form a shell around a polyamine core, which is responsible for the screening of positive charges. MTT experiments show that the screening of amine groups decreases nanoparticle toxicity, with the lowest toxicity for the 10 PEG/PAH ratio. Fluorescence correlation spectroscopy (FCS) proves less interaction with proteins for PEGylated PANs. Positron emission tomography (PET) imaging of 18 F labelled PANs shows longer circulation time in healthy mice for PEGylated PANs than non-PEGylated ones.
Collapse
Affiliation(s)
- Patrizia Andreozzi
- Soft Matter Nanotechnology Group, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
- Consorzio Sistemi a Grande Interfase, Department of Chemistry 'Ugo Schiff', University of Florence, Via della Lastruccia 3, Sesto Fiorentino, Florence, 50019, Italy
| | - Cristina Simó
- Soft Matter Nanotechnology Group, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
- Radiochemistry and Nuclear Imaging Group, CIC biomaGUNE, Basque Research and Tech-nology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
| | - Paolo Moretti
- Dipartimento di Scienze della Vita e dell'Ambiente, Università Politecnica delle Marche, Via brecce bianche, Ancona, I-60131, Italy
| | - Joaquin Martinez Porcel
- Soft Matter Nanotechnology Group, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
| | - Tanja Ursula Lüdtke
- Soft Matter Nanotechnology Group, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
| | - Maria de Los Angeles Ramirez
- Soft Matter Nanotechnology Group, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
- Instituto de Nanosistemas, UNSAM, CONICET, Avenida 25 de Mayo 1021, San Martín, Buenos Aires, 1650, Argentina
| | - Lorenza Tamberi
- Soft Matter Nanotechnology Group, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
| | - Marco Marradi
- Department of Chemistry 'Ugo Schiff', University of Florence, Via della Lastruccia 3/13, Sesto Fiorentino, Florence, 50019, Italy
| | - Heinz Amenitsch
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayergasse 9/V, Graz, 8010, Austria
| | - Jordi Llop
- Radiochemistry and Nuclear Imaging Group, CIC biomaGUNE, Basque Research and Tech-nology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
- Centro de Investigación Biomédica en Red - Enfermedades Respiratorias (CIBERES), Av. Monforte de Lemos, 3-5, Madrid, 28029, Spain
| | - Maria Grazia Ortore
- Dipartimento di Scienze della Vita e dell'Ambiente, Università Politecnica delle Marche, Via brecce bianche, Ancona, I-60131, Italy
| | - Sergio Enrique Moya
- Soft Matter Nanotechnology Group, CIC biomaGUNE, Basque Research and Technology Alliance (BRTA), Paseo Miramón 182, San Sebastián, Guipúzcoa, 20014, Spain
| |
Collapse
|
15
|
Micro-CT and Microscopy Study of Internal and Marginal Gap to Tooth Surface of Crenelated versus Conventional Dental Indirect Veneers. ACTA ACUST UNITED AC 2021; 57:medicina57080772. [PMID: 34440981 PMCID: PMC8400834 DOI: 10.3390/medicina57080772] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Revised: 07/26/2021] [Accepted: 07/27/2021] [Indexed: 12/24/2022]
Abstract
Background and Objectives: Ceramic veneers represent the most appropriate treatment option for minimally invasive aesthetic rehabilitation. For long-term clinical success, the accurate marginal and internal adaptation of dental restorations are of paramount importance. The aim of this in vitro study is to assess the effect of a novel (patented) design of veneers compared to conventional ones on their marginal and internal gap to the prepared tooth surface. Materials and Methods: Twenty-four lithium disilicate ceramic veneers are obtained using Computer-Aided-Design (CAD) and then milled using Computer-Aided-Manufacturing (CAM). The samples are divided into two groups: 12 conventional (CO) veneers (i.e., with a linear marginal contour) and 12 crenelated (CR) veneers, the latter with the novel sinusoidal marginal design. All samples are bonded to frontal teeth, and the adhesive interfaces are analyzed using two methods, optical microscopy and micro-Computed Tomography (CT): the former for the accuracy of the marginal gap and the latter for the internal gap (as well as for the homogeneity of the luting cement) of ceramic veneers. Results: STATA and one-way ANOVA tests reveal significant differences between CO and CR veneers: (i) the marginal gap is smaller for CR (64 μm) than for CO veneers (236 μm); (ii) the internal adaptation is better for CR veneers: for a cement width of up to 120 μm, the covered surface for the CR group is 81.5%, while for the CO group it is 64.5%; (iii) the mean of the porosities within the cement is not significantly different (3.4·106 μm3 for CO and 3.9·106 μm3 for CR veneers), with a higher standard deviation for the CO group. Analytical modeling is achieved for internal gaps using the micro-CT results. The characteristic functions obtained allow us to compare the volume of luting cement for the two types of veneers. Conclusion: The novel veneers design produces an improvement in the marginal and internal adaptation of the restorations to the prepared tooth surface. Thus, it provides favorable premises for better clinical performances.
Collapse
|
16
|
Distinct connectivity profiles predict different in-time processes of motor skill learning. Neuroimage 2021; 238:118239. [PMID: 34119637 DOI: 10.1016/j.neuroimage.2021.118239] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 05/20/2021] [Accepted: 06/03/2021] [Indexed: 11/24/2022] Open
Abstract
Learning through intensive practice has been largely observed in motor, sensory and higher-order cognitive processing. Neuroimaging studies have shown that learning phases are associated with different patterns of functional and structural neural plasticity in spatially distributed brain systems. Yet, it is unknown whether distinct neural signatures before practice can foster different subsequent learning stages over time. Here, we employed a bimanual implicit sequence reaction time task (SRTT) to investigate whether the rates of early (one day after practice) and late (one month after practice) post-training motor skill learning were predicted by distinct patterns of pre-training resting state functional connectivity (rs-FC), recorded with functional MRI. We observed that both motor learning descriptors were positively correlated with the strength of rs-FC among pairs of regions within a SRTT-relevant network comprising cerebellar as well as cortical and subcortical motor areas. Crucially, we detected a double dissociation such that early post-training learning was significantly associated with the functional connections within cerebellar regions, whereas late post-training learning was significantly related to the functional connections between cortical and subcortical motor areas. These findings indicate that spontaneous brain activity prospectively carries out behaviorally relevant information to perform experience-dependent cognitive operations far distant in time.
Collapse
|
17
|
Capuani S, Gambarini G, Guarnieri R, Di Pietro G, Testarelli L, Di Nardo D. Nuclear Magnetic Resonance Microimaging for the Qualitative Assessment of Root Canal Treatment: An Ex Vivo Preliminary Study. Diagnostics (Basel) 2021; 11:1012. [PMID: 34205946 PMCID: PMC8228494 DOI: 10.3390/diagnostics11061012] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 05/27/2021] [Accepted: 05/30/2021] [Indexed: 02/07/2023] Open
Abstract
AIM To assess the potential ability of nuclear magnetic resonance micro-imaging (mMRI) to visualize and identify soft tissue debris and unfilled spaces inside radicular canals in endodontic treated extracted teeth, for understanding the causes of treatment failure. Toward this goal, multi-parametric mMRI and cone beam computed tomography (CBCT) were compared. METHODOLOGY A non-recoverable root treated human tooth was extracted due to endodontic failure and excessive mobility. It was examined with both CBCT and mMRI: CBCT was performed with 0.125 mm voxel size (GXCB-500, Kavo-Gendex, Brea, CA, USA) and mMRI was performed with a spectrometer operating at 9.4T magnetic field (Bruker Avance-400, Bruker, Billerica, MA, USA). The mMRI images were obtained with a microimaging probe. Relaxation times (T1 and T2) and diffusion-weighted acquisition sequences were used to obtain multi-parametric maps of the extracted tooth (slice thickness of 200 µm and in plane resolution of 30 × 30 µm2). RESULTS T1 and T2 maps identified unfilled spaces around and close to Gutta-percha cones instead of CBCT images that were not able to highlight this aspect. T1, T2 and apparent diffusion coefficient (ADC) assumed different values in dentine and in voids, characterized by different dimensions. Moreover, they were able to discriminate between infiltrations of water only and deposits of biological material. Because Gutta-percha cones are constituted of hard, non-porous material, they do not provide a signal and in mMRI images appear as zones of noise. CONCLUSIONS Unlike the CBCT exam, mMRI can detect soft tissue debris and unfilled spaces inside radicular canals. Therefore, this in vitro study showed the potential of mMRI to evaluate the quality of the root canal treatment, suggesting its potential benefit in determining the causes of endodontic failure, without the use of ionizing radiation.
Collapse
Affiliation(s)
- Silvia Capuani
- CNR ISC c/o Physics Department, Sapienza University of Rome, 00185 Rome, Italy; (S.C.); (G.D.P.)
- Museo Storico Della Fisica e Centro Studi e Ricerche Enrico Fermi, 00185 Rome, Italy
| | - Gianluca Gambarini
- Department of Oral and Maxillo Facial Sciences, Sapienza Università di Roma, 00161 Rome, Italy; (G.G.); (R.G.); (D.D.N.)
| | - Renzo Guarnieri
- Department of Oral and Maxillo Facial Sciences, Sapienza Università di Roma, 00161 Rome, Italy; (G.G.); (R.G.); (D.D.N.)
| | - Giulia Di Pietro
- CNR ISC c/o Physics Department, Sapienza University of Rome, 00185 Rome, Italy; (S.C.); (G.D.P.)
| | - Luca Testarelli
- Department of Oral and Maxillo Facial Sciences, Sapienza Università di Roma, 00161 Rome, Italy; (G.G.); (R.G.); (D.D.N.)
| | - Dario Di Nardo
- Department of Oral and Maxillo Facial Sciences, Sapienza Università di Roma, 00161 Rome, Italy; (G.G.); (R.G.); (D.D.N.)
| |
Collapse
|
18
|
de Pasquale F, Spadone S, Betti V, Corbetta M, Della Penna S. Temporal modes of hub synchronization at rest. Neuroimage 2021; 235:118005. [PMID: 33819608 DOI: 10.1016/j.neuroimage.2021.118005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 03/12/2021] [Accepted: 03/17/2021] [Indexed: 10/21/2022] Open
Abstract
The brain is a dynamic system that generates a broad repertoire of perceptual, motor, and cognitive states by the integration and segregation of different functional domains represented in large-scale brain networks. However, the fundamental mechanisms underlying brain network integration remain elusive. Here, for the first time to our knowledge, we found that in the resting state the brain visits few synchronization modes defined as clusters of temporally aligned functional hubs. These modes alternate over time and their probability of switching leads to specific temporal loops among them. Notably, although each mode involves a small set of nodes, the brain integration seems highly vulnerable to a simulated attack on this temporal synchronization mechanism. In line with the hypothesis that the resting state represents a prior sculpted by the task activity, the observed synchronization modes might be interpreted as a temporal brain template needed to respond to task/environmental demands .
Collapse
Affiliation(s)
- F de Pasquale
- Faculty of Veterinary Medicine, University of Teramo, Teramo, Italy.
| | - S Spadone
- Department of Neuroscience, Imaging and Clinical Sciences, and Institute for Advanced Biomedical Technologies, "G. d'Annunzio" University of Chieti-Pescara, Chieti, Italy
| | - V Betti
- Department of Psychology, Sapienza University of Rome, 00185, Rome, Italy; IRCCS Fondazione Santa Lucia, 00142, Rome, Italy
| | - M Corbetta
- Department of Neuroscience and Padova Neuroscience Center (PNC), University of Padua, Padua, Italy; Venetian Institute of Molecular Medicine (VIMM), Padua, Italy; Department of Neurology, Radiology, and Neuroscience, Washington University St. Louis
| | - S Della Penna
- Department of Neuroscience, Imaging and Clinical Sciences, and Institute for Advanced Biomedical Technologies, "G. d'Annunzio" University of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
19
|
Berry DB, Englund EK, Chen S, Frank LR, Ward SR. Medical imaging of tissue engineering and regenerative medicine constructs. Biomater Sci 2021; 9:301-314. [PMID: 32776044 PMCID: PMC8262082 DOI: 10.1039/d0bm00705f] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Advancement of tissue engineering and regenerative medicine (TERM) strategies to replicate tissue structure and function has led to the need for noninvasive assessment of key outcome measures of a construct's state, biocompatibility, and function. Histology based approaches are traditionally used in pre-clinical animal experiments, but are not always feasible or practical if a TERM construct is going to be tested for human use. In order to transition these therapies from benchtop to bedside, rigorously validated imaging techniques must be utilized that are sensitive to key outcome measures that fulfill the FDA standards for TERM construct evaluation. This review discusses key outcome measures for TERM constructs and various clinical- and research-based imaging techniques that can be used to assess them. Potential applications and limitations of these techniques are discussed, as well as resources for the processing, analysis, and interpretation of biomedical images.
Collapse
Affiliation(s)
- David B Berry
- Departments of NanoEngineering, University of California, San Diego, USA.
| | | | | | | | | |
Collapse
|
20
|
Irie MS, Rabelo GD, Spin-Neto R, Dechichi P, Borges JS, Soares PBF. Use of Micro-Computed Tomography for Bone Evaluation in Dentistry. Braz Dent J 2019; 29:227-238. [PMID: 29972447 DOI: 10.1590/0103-6440201801979] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 03/27/2018] [Indexed: 01/20/2023] Open
Abstract
Micro computed tomography (µCT) follows the same principle of computed-tomography used for patients, however providing higher-resolution. Using a non-destructive approach, samples can be scanned, and each section obtained is used to build a volume using tridimensional reconstruction. For bone analysis, it is possible to obtain information about the tissue's microarchitecture and composition. According to the characteristics of the bone sample (e.g. human or animal origin, long or irregular shape, epiphysis or diaphysis region) the pre-scanning parameters must be defined. The resolution (i.e. voxel size) should be chosen taking into account the features that will be evaluated, and the necessity to identify inner structures (e.g. bone channels and osteocyte lacunae). The region of interest should be delimited, and the threshold that defines the bone tissue set in order to proceed with binarization to separate the voxels representing bone from the other structures (channels, resorption areas, and medullary space). Cancellous bone is evaluated by means of the trabeculae characteristics and their connectivity. The cortex is evaluated in relation to the thickness and porosity. Bone mineral density can also be measured, by the amount of hydroxyapatite. Other parameters such as structure-model-index, anisotropy, and fractal dimension can be assessed. In conclusion, intrinsic and extrinsic determinants of bone quality can be assessed by µCT. In dentistry, this method can be used for evaluating bone loss, alterations in bone metabolism, or the effects of using drugs that impair bone remodeling, and also to assess the success rate of bone repair or surgical procedures.
Collapse
Affiliation(s)
- Milena Suemi Irie
- Department of Periodontology and Implantology, UFU - Universidade Federal de Uberlândia, Uberlândia, MG, Brazil
| | - Gustavo Davi Rabelo
- Department of Periodontology and Implantology, UFU - Universidade Federal de Uberlândia, Uberlândia, MG, Brazil
| | - Rubens Spin-Neto
- Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark
| | - Paula Dechichi
- Institute of Biomedical Sciences, UFU - Universidade Federal de Uberlândia, Uberlândia, MG, Brazil
| | - Juliana Simeão Borges
- Department of Periodontology and Implantology, UFU - Universidade Federal de Uberlândia, Uberlândia, MG, Brazil
| | | |
Collapse
|
21
|
Fan Y, Antonijević D, Zhong X, Komlev VS, Li Z, Đurić M, Fan Y. Three-Dimensional Reconstruction of Erythrocytes Using the Novel Method For Corrective Realignment of the Transmission Electron Microscopy Cross-Section Images. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2018; 24:676-683. [PMID: 30588909 DOI: 10.1017/s1431927618015325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The detailed kinetics study of erythrocyte deformability is useful for the early diagnosis of blood diseases and for monitoring the blood rheology. Present solutions for a three-dimensional (3D) reconstruction of erythrocytes has a limited potential. This study aimed to use erythrocyte transmission electron images (ETIs) to evaluate the morphological relationship between adjacent ETIs and generate erythrocytes 3D model. First, ultrathin serial sections of skeletal muscle tissue were obtained using an ultramicrotome. Further, the set of ETIs in a capillary were captured by transmission electron microscopy. The images were aligned by translations and rotations using custom software to optimize the morphological relationship between adjacent ETIs. These coordinate transformations exploit the unique principal axis of inertia of each image to define the body coordinate system and hence provide the means to accurately reconnect the adjacent ETIs. The sum of the distances between the corresponding points on the boundary of adjacent ETIs was minimized and, further, was optimized by using physiological relationship between the adjacent ETIs. The analysis allowed to define precise virtual relationship between the adjacent erythrocytes. Finally, extracted erythrocytes' cross-section images allowed to generate 3D model of the erythrocytes.
Collapse
Affiliation(s)
- Yuzhou Fan
- 1School of Physical Education and Sport Science,Fujian Normal University,350108 Fuzhou,China
| | - Djordje Antonijević
- 1School of Physical Education and Sport Science,Fujian Normal University,350108 Fuzhou,China
| | - Xing Zhong
- 5Medical Imaging Center,The First Affiliated Hospital of Jinan University,510632 Guangzhou,China
| | - Vladimir S Komlev
- 6A. A. Baikov Institute of Metallurgy and Materials Science,119334 Moscow,Russia
| | - Zhiyu Li
- 7College of Foreign Studies,Jinan University,510632 Guangzhou,China
| | - Marija Đurić
- 3Laboratory for Anthropology,Institute for Anatomy,School of Medicine,University of Belgrade,11000 Belgrade,Serbia
| | - Yifang Fan
- 1School of Physical Education and Sport Science,Fujian Normal University,350108 Fuzhou,China
| |
Collapse
|
22
|
Optimized 3D co-registration of ultra-low-field and high-field magnetic resonance images. PLoS One 2018; 13:e0193890. [PMID: 29509780 PMCID: PMC5839578 DOI: 10.1371/journal.pone.0193890] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Accepted: 02/19/2018] [Indexed: 12/19/2022] Open
Abstract
The prototypes of ultra-low-field (ULF) MRI scanners developed in recent years represent new, innovative, cost-effective and safer systems, which are suitable to be integrated in multi-modal (Magnetoencephalography and MRI) devices. Integrated ULF-MRI and MEG scanners could represent an ideal solution to obtain functional (MEG) and anatomical (ULF MRI) information in the same environment, without errors that may limit source reconstruction accuracy. However, the low resolution and signal-to-noise ratio (SNR) of ULF images, as well as their limited coverage, do not generally allow for the construction of an accurate individual volume conductor model suitable for MEG localization. Thus, for practical usage, a high-field (HF) MRI image is also acquired, and the HF-MRI images are co-registered to the ULF-MRI ones. We address here this issue through an optimized pipeline (SWIM—Sliding WIndow grouping supporting Mutual information). The co-registration is performed by an affine transformation, the parameters of which are estimated using Normalized Mutual Information as the cost function, and Adaptive Simulated Annealing as the minimization algorithm. The sub-voxel resolution of the ULF images is handled by a sliding-window approach applying multiple grouping strategies to down-sample HF MRI to the ULF-MRI resolution. The pipeline has been tested on phantom and real data from different ULF-MRI devices, and comparison with well-known toolboxes for fMRI analysis has been performed. Our pipeline always outperformed the fMRI toolboxes (FSL and SPM). The HF–ULF MRI co-registration obtained by means of our pipeline could lead to an effective integration of ULF MRI with MEG, with the aim of improving localization accuracy, but also to help exploit ULF MRI in tumor imaging.
Collapse
|