1
|
Ittleman B, Lowenstein S, Edwards LA, Caris E, Bhat A, Conwell J, Lewin M, Arya B. Fetal Echocardiographic Evaluation of Tricuspid Valve and Right Ventricular Function Including Global Longitudinal Strain in Hypoplastic Left Heart Syndrome and Association with Postnatal Outcomes. Pediatr Cardiol 2024:10.1007/s00246-024-03453-5. [PMID: 38647657 DOI: 10.1007/s00246-024-03453-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 02/12/2024] [Indexed: 04/25/2024]
Abstract
Despite significant advancements in the care of patients with hypoplastic left heart syndrome (HLHS) morbidity and mortality remain high. Postnatal right ventricular dysfunction and tricuspid regurgitation (TR) are associated with worse outcomes in HLHS. We aim to determine if right ventricle functional parameters and TR on fetal echocardiogram are associated with postnatal outcomes in HLHS patients. Retrospective review was performed on all fetuses with HLHS from 2014 to 2022 at our institution. Initial and follow up fetal echocardiogram measurements of right ventricular myocardial performance index (MPI), fractional area change (FAC) and global longitudinal strain (GLS) were retrospectively measured. The presence and severity of TR was recorded from the fetal echocardiogram reports. Postnatal outcomes including transplant-free survival, hospital length of stay > 30 days after initial palliation and need for bidirectional Glenn at < 4 months were reviewed. Forty-three subjects met inclusion criteria. Mean gestational age at presentation was 26.1 ± 5.9 weeks. Nine subjects died and 3 required heart transplantation. Initial fetal echocardiogram MPI was significantly lower (better) (0.36 ± 0.06 vs 0.44 ± 0.11; p = < 0.001) and FAC was significantly higher (better) (45 ± 6% vs 40 ± 8%; p = 0.035) in transplant-free survivors. Fetal right ventricular GLS and presence of mild TR were not associated with postnatal outcome. In fetuses with HLHS, abnormal MPI and right ventricular FAC are associated with decreased transplant-free survival. There was no observed association between GLS and postnatal outcomes. To our knowledge this is the first study examining fetal right ventricular function and GLS in HLHS patients and its link to postnatal outcomes.
Collapse
Affiliation(s)
- Benjamin Ittleman
- Arkansas Children's Hospital, University of Arkansas Medical Sciences, Little Rock, AR, USA.
| | | | - Lindsay A Edwards
- Department of Pediatrics, Division of Cardiology, Duke University School of Medicine, Durham, NC, USA
| | - Elizabeth Caris
- University of Pittsburgh School of Medicine, University of Pittsburgh Medical Center Children's Hospital of Pittsburgh, Pittsburgh, PA, USA
| | - Aarti Bhat
- Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, USA
| | - Jeffrey Conwell
- Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, USA
| | - Mark Lewin
- Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, USA
| | - Bhawna Arya
- Seattle Children's Hospital, University of Washington School of Medicine, Seattle, WA, USA
| |
Collapse
|
2
|
Avnet H, Thomas S, Beirne G, Alphonse J, Welsh A. Poor Correlation between Fetal Tissue Doppler Imaging and Pulsed Wave Myocardial Performance Indices. Fetal Diagn Ther 2023; 50:225-235. [PMID: 36948159 DOI: 10.1159/000529945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 02/21/2023] [Indexed: 03/24/2023]
Abstract
INTRODUCTION Both tissue Doppler imaging (TDI) and pulsed wave Doppler (PWD) Myocardial Performance Indices (MPIs) have been proposed as tools for functional fetal cardiology. We wished to determine if there was any correlation between TDI-MPI and PWD-MPI. METHODS A cohort of uncomplicated women with morphologically normal singleton fetuses between 22 and 39 weeks of gestation was recruited. A single sonologist acquired Doppler waveforms for evaluation of both left and right TDI-MPI and PWD-MPI. The PWD-MPI values were calculated using a previously published algorithm and the TDI-MPI time intervals were measured manually by a single operator. RESULTS Achievability and repeatability were high for both modalities. TDI produced significantly lower right MPI values yet significantly higher left MPI values, potentially reflecting their evaluation of physiologically different events, blood flow versus myocardial contraction. CONCLUSION This study demonstrates that MPIs measured from PWD and TDI have a weak correlation and cannot be used interchangeably, even with the exclusion of suboptimal TDI-MPI scans from the analysis. Given the lack of correlation between the two methods, the high variation in TDI waveform, and the lack of unified approach to TDI analysis, we feel further research is needed before adoption of this technique.
Collapse
Affiliation(s)
- Hagai Avnet
- School of Women's and Children's Health, University of New South Wales, Sydney, New South Wales, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women Sydney, Randwick, New South Wales, Australia
| | - Samantha Thomas
- School of Women's and Children's Health, University of New South Wales, Sydney, New South Wales, Australia
| | - Geraldene Beirne
- School of Women's and Children's Health, University of New South Wales, Sydney, New South Wales, Australia
| | - Jennifer Alphonse
- School of Women's and Children's Health, University of New South Wales, Sydney, New South Wales, Australia
| | - Alec Welsh
- School of Women's and Children's Health, University of New South Wales, Sydney, New South Wales, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women Sydney, Randwick, New South Wales, Australia
| |
Collapse
|
3
|
Dondi M, Rodella C, Giubbini R, Camoni L, Karthikeyan G, Vitola JV, Einstein AJ, Arends BJ, Morozova O, Pascual TN, Paez D. Inter-reader variability of SPECT MPI readings in low- and middle-income countries: Results from the IAEA-MPI Audit Project (I-MAP). J Nucl Cardiol 2020; 27:465-478. [PMID: 30168029 PMCID: PMC7174263 DOI: 10.1007/s12350-018-1407-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Accepted: 08/03/2018] [Indexed: 10/29/2022]
Abstract
BACKGROUND Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab. METHODS The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups. RESULTS Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis. CONCLUSIONS In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries.
Collapse
Affiliation(s)
- Maurizio Dondi
- Nuclear Medicine Department, University of Brescia, Brescia, Italy.
- Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health, International Atomic Energy Agency, Vienna, Austria.
| | - Carlo Rodella
- Department of Medical Physics, Spedali Civili di Brescia, Brescia, Italy
| | | | - Luca Camoni
- Nuclear Medicine Department, University of Brescia, Brescia, Italy
| | - Ganesan Karthikeyan
- Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India
| | | | - Andrew J Einstein
- Department of Medicine, Division of Cardiology, and Department of Radiology, Columbia University Irving Medical Center, New York, USA
| | - Bertjan J Arends
- Department of Medical Physics, Catharina Hospital, Eindhoven, The Netherlands
| | - Olga Morozova
- Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health, International Atomic Energy Agency, Vienna, Austria
| | - Thomas N Pascual
- Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health, International Atomic Energy Agency, Vienna, Austria
| | - Diana Paez
- Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health, International Atomic Energy Agency, Vienna, Austria
| |
Collapse
|
4
|
Bi WJ, Cui L, Xiao YJ, Song G, Wang X, Sun L, Qiao W, Ren WD. Assessing cardiovascular remodelling in fetuses and infants conceived by assisted reproductive technologies: a prospective observational cohort study protocol. BMJ Open 2019; 9:e031452. [PMID: 31662389 PMCID: PMC6830675 DOI: 10.1136/bmjopen-2019-031452] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
INTRODUCTION Assisted reproductive technologies (ART), namely in vitro fertilisation and intracytoplasmic sperm injection, have become widely used to treat infertility. Although the use of ART is generally considered favourable, there are ongoing concerns about the prenatal and perinatal risks as well as long-term risks for the child. Epidemiological studies have demonstrated an association between pathological events during fetal development and future cardiovascular risk, raising concerns about cardiovascular remodelling in fetuses conceived by ART. The authors hypothesise fetuses conceived by ART present signs of cardioventricular dysfunction, which can be detected by deformation analysis. To address these issues, we will assess comprehensive cardiovascular structure and function in ART offspring and explore the role of speckle-tracking in myocardial deformation. METHODS AND ANALYSIS This prospective observational cohort study will include 100 singleton pregnancies conceived by ART and 100 controls identified in fetal life and followed up to 6 months old. At inclusion, a baseline assessment of the mothers and ART characteristics will be recorded by interview and review of medical records. Between 28 and 32 weeks gestation, a detailed fetal echography will be performed, including an assessment of estimated fetal weight, fetoplacental Doppler, fetal echocardiography and fetal abdominal artery ultrasound. On delivery, maternal and neonatal characteristics will be assessed. Within 60 days of birth, the first postnatal cardiovascular assessment will be conducted which will include echocardiography and abdominal artery ultrasound. At 6 months of age, the second infants' follow-up evaluation will include the weight and length of the infant, echocardiography and abdominal artery ultrasound. Data will be presented as mean±SD, median or percentages where appropriate. A p<0.05 will be considered statistically significant. ETHICS AND DISSEMINATION Ethical approval has been obtained from the Ethics Committee of Shengjing Hospital of China Medical University. Findings will be disseminated through scientific publications and conference presentations. TRIAL REGISTRATION NUMBER ChiCTR1900021672.
Collapse
Affiliation(s)
- Wen-Jing Bi
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Li Cui
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Yang-Jie Xiao
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Guang Song
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Xin Wang
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Lu Sun
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Wei Qiao
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Wei-Dong Ren
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| |
Collapse
|
5
|
Gijtenbeek M, Eschbach SJ, Middeldorp JM, Klumper FJCM, Slaghekke F, Oepkes D, Haak MC. The value of echocardiography and Doppler in the prediction of fetal demise after laser coagulation for TTTS: A systematic review and meta-analysis. Prenat Diagn 2019; 39:838-847. [PMID: 31237967 PMCID: PMC6771838 DOI: 10.1002/pd.5511] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 05/09/2019] [Accepted: 06/18/2019] [Indexed: 01/10/2023]
Abstract
This study aimed to investigate the value of echocardiography and Doppler before fetoscopic laser coagulation for twin‐twin transfusion syndrome (TTTS) in the prediction of intrauterine fetal demise (IUFD). We performed a systematic review and meta‐analysis to compare preoperative parameters between fetuses with and without demise after laser surgery. Eighteen studies were included. Recipient twins have an increased risk of demise in case of preoperative absent/reversed flow (A/REDF) in the umbilical artery (odds ratio [OR] 2.76, 95% confidence interval [CI], 1.78‐4.28), absent or reversed a‐wave in the ductus venosus (OR 2.32, 95% CI, 1.70‐3.16), or a middle cerebral artery peak systolic velocity > 1.5 multiples of the median (MoM) (OR 7.59, 95% CI, 2.56‐22.46). In donors, only A/REDF in the umbilical artery (OR 3.40, 95% CI, 2.68‐4.32) and absent or reversed a‐wave in the ductus venosus (OR 1.66, 95% CI, 1.12‐2.47) were associated with IUFD. No association was found between donor‐IUFD and preoperative myocardial performance index (MPI). Two studies found an association between abnormal MPI and recipient demise. With this study, we have identified a set of preoperative Doppler parameters predictive of fetal demise after laser surgery. More research is needed to assess the utility of preoperative echocardiographic parameters such as the MPI in predicting IUFD. What's already known about this topic?
Doppler parameters are associated with fetal demise after laser surgery. Echocardiographic parameters are currently not used in risk stratification.
What does this study add?
A more extensive set of preoperative Doppler parameters is defined to predict post‐laser fetal demise. The utility of preoperative echocardiographic parameters such as the MPI in predicting fetal demise remains unclear.
Collapse
Affiliation(s)
- Manon Gijtenbeek
- Department of Obstetrics, Division of Fetal Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Sanne J Eschbach
- Department of Obstetrics, Division of Fetal Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Johanna M Middeldorp
- Department of Obstetrics, Division of Fetal Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Frans J C M Klumper
- Department of Obstetrics, Division of Fetal Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Femke Slaghekke
- Department of Obstetrics, Division of Fetal Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Dick Oepkes
- Department of Obstetrics, Division of Fetal Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Monique C Haak
- Department of Obstetrics, Division of Fetal Medicine, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
6
|
Henry A, Alphonse J, Tynan D, Welsh AW. Fetal myocardial performance index in assessment and management of small-for-gestational-age fetus: a cohort and nested case-control study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 51:225-235. [PMID: 28345186 DOI: 10.1002/uog.17476] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 01/27/2017] [Accepted: 03/17/2017] [Indexed: 06/06/2023]
Abstract
OBJECTIVE To assess the clinical utility of the fetal myocardial performance index (MPI) in assessment and management of the small-for-gestational-age (SGA) fetus/growth-restricted fetus (FGR). METHODS This was a prospective cohort study in metropolitan Australia of patients referred in the period June 2012 to March 2015 to fetal medicine services at 24-38 weeks' gestation for suspected singleton SGA/FGR (estimated fetal weight (EFW) < 10th centile with or without abnormal umbilical artery (UA) Doppler) pregnancy. Patients had MPI assessed in addition to routine measures, and were followed through to birth. We compared MPI values against those of a local reference population and gestational age-matched controls, and assessed the correlation with perinatal outcome and other Doppler measures. RESULTS Fifty-two cases were included, 38 diagnosed < 32 weeks and 14 diagnosed ≥ 32 weeks. None demonstrated significantly elevated left, right or delta MPI compared with the reference population or with gestational age-matched controls at the time of first MPI evaluation. There were no consistent longitudinal patterns in MPI that would suggest its clinical utility. The mean ± SD gestational age at delivery was 34.6 ± 3.8 weeks and birth weight was 1.7 ± 0.6 kg, and the median neonatal hospital admission time was 27 days, confirming a pathological cohort. There were no significant correlations between left, right or delta-MPI and perinatal outcome, although there were significant correlations between UA, middle cerebral artery (MCA) and ductus venosus (DV) Doppler and perinatal outcome (birth weight, gestational age at birth and length of neonatal hospital stay). Exploratory subgroup comparisons (EFW < 3rd vs 3rd -10th centile; early- vs late-onset; abnormal vs normal UA Doppler) found only minor differences in MPI, reaching statistical, but not clinical, significance, only in the EFW < 3rd vs 3rd -10th centile comparison. CONCLUSIONS MPI did not demonstrate clinical utility in either triage or longitudinal follow-up of an SGA/FGR cohort presenting to fetal medicine services. Given that prior research suggesting its utility originates from single-center cohorts, while multicenter, large cohorts have suggested little utility or no additional utility if routine UA/MCA/DV Doppler is performed, publication bias may have affected previous reports. It seems unlikely that MPI has clinical utility in assessment and management of SGA/FGR fetuses. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- A Henry
- School of Women's and Children's Health, UNSW Medicine, University of New South Wales, Sydney, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Sydney, Australia
- Department of Women's and Children's Health, St George Hospital, Sydney, Australia
| | - J Alphonse
- School of Women's and Children's Health, UNSW Medicine, University of New South Wales, Sydney, Australia
| | - D Tynan
- School of Women's and Children's Health, UNSW Medicine, University of New South Wales, Sydney, Australia
| | - A W Welsh
- School of Women's and Children's Health, UNSW Medicine, University of New South Wales, Sydney, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Sydney, Australia
| |
Collapse
|
7
|
Henry A, Gopikrishna S, Mahajan A, Alphonse J, Meriki N, Welsh AW. Use of the Foetal Myocardial Performance Index in monochorionic, diamniotic twin pregnancy: a prospective cohort and nested case-control study. J Matern Fetal Neonatal Med 2018; 32:2017-2029. [DOI: 10.1080/14767058.2018.1424817] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Amanda Henry
- School of Women’s and Children’s Health, UNSW Medicine, UNSW, Sydney, Australia
- Department of Women’s and Children’s Health, St. George Hospital, Sydney, Australia
- Department of Maternal Fetal Medicine, Royal Hospital for Women, Sydney, Australia
| | - Saranya Gopikrishna
- School of Women’s and Children’s Health, UNSW Medicine, UNSW, Sydney, Australia
| | - Aditi Mahajan
- School of Women’s and Children’s Health, UNSW Medicine, UNSW, Sydney, Australia
- Royal Prince Alfred Hospital, Camperdown, Sydney, Australia
| | - Jennifer Alphonse
- School of Women’s and Children’s Health, UNSW Medicine, UNSW, Sydney, Australia
| | - Neama Meriki
- Department of Obstetrics and Gynaecology, College of Medicine, King Saud University, Riyadh, Saudi Arabia
- Maternal Fetal Medicine, King Khalid University Hospital, Riyadh, Saudi Arabia
| | - Alec W. Welsh
- School of Women’s and Children’s Health, UNSW Medicine, UNSW, Sydney, Australia
- Department of Maternal Fetal Medicine, Royal Hospital for Women, Sydney, Australia
| |
Collapse
|
8
|
Zeng S, Zhou J, Peng Q, Deng W, Zang M, Wang T, Zhou Q. Sustained Chronic Maternal Hyperoxygenation Increases Myocardial Deformation in Fetuses with a Small Aortic Isthmus at Risk for Coarctation. J Am Soc Echocardiogr 2017; 30:992-1000. [DOI: 10.1016/j.echo.2017.05.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Indexed: 10/19/2022]
|
9
|
Lee MY, Won HS, Shim JY, Lee PR, Kim A, Kil EM, Kim MJ. Novel Technique for Measurement of Fetal Right Myocardial Performance Index Using Dual Gate Pulsed-Wave Doppler. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:1585-1594. [PMID: 28503785 DOI: 10.7863/ultra.16.07079] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Accepted: 10/11/2016] [Indexed: 06/07/2023]
Abstract
OBJECTIVES To evaluate the reproducibility of the fetal right myocardial performance index determined by simultaneous recording of inflow and outflow using a dual gate pulsed-wave Doppler (DD). METHODS This was a prospective study of 39 normal singleton fetuses. Two experienced operators each measured the right myocardial performance index in three ways, twice: (1) separate recording of the inflow and outflow using single-gate pulsed-wave Doppler (PD), (2) simultaneous recordings of the inflow and outflow using tissue Doppler (TD), and (3) simultaneous recordings of the inflow and outflow using DD. Intra- and interoperator reproducibility were assessed with intraclass correlation coefficients. The measurements from all three methods taken by the more experienced operator were compared using Bland-Altman plots and mean differences. RESULTS For both operators, intra-operator reproducibility was the highest when using DD, followed by PD, and TD. Interoperator agreement was the highest for PD measurements, followed by DD, and TD. The smallest mean difference was between the PD and DD measurements by the more experienced operator. There was a positive correlation between PD and DD values (r = 0.369, P < .001). CONCLUSIONS Dual gate pulsed-wave Doppler may be an effective alternative to the PD or TD methods, and can separately evaluate systolic and diastolic myocardial function.
Collapse
Affiliation(s)
- Mi-Young Lee
- Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| | - Hye-Sung Won
- Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| | - Jae-Yoon Shim
- Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| | - Pil-Ryang Lee
- Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| | - Ahm Kim
- Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| | - Eun-Mi Kil
- Clinical Support Team, Hitachi Aloka Medical Korea Ltd, Seoul, South Korea
| | - Min-Ju Kim
- Department of Clinical Epidemiology and Biostatistics, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| |
Collapse
|
10
|
Meriki N, Welsh AW. Fetal cardiac function: Feasibility in obtaining the right modified myocardial performance index in a single Doppler waveform. Australas J Ultrasound Med 2017; 20:18-25. [DOI: 10.1002/ajum.12035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Affiliation(s)
- Neama Meriki
- Department of Maternal fetal Medicine King Khalid University Hospital Riyadh Saudi Arabia
- Department of Obstetrics & Gynaecology College of Medicine King Saud University Riyadh Saudi Arabia
| | - Alec W Welsh
- Department of Maternal‐Fetal Medicine Royal Hospital for WomenRandwick New South Wales Australia
- Division of Women's and Children's Health University of New South Wales Randwick New South Wales Australia
- Australian Centre for Perinatal Science University of New South Wales Randwick New South Wales Australia
| |
Collapse
|
11
|
Welsh AW, Maheshwari P, Wang J, Henry A, Chang D, Crispi F, Gardiner HM, Hernandez-Andrade E, Meriki N, Redmond S, Yagel S. Evaluation of an automated fetal myocardial performance index. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2016; 48:496-503. [PMID: 26423314 DOI: 10.1002/uog.15770] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 09/17/2015] [Accepted: 09/26/2015] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To compare automated measurements of the fetal left myocardial performance index (MPI) with manual measurements for absolute value, repeatability and waveform acceptability. METHODS This was a multicenter international online study using images from uncomplicated, morphologically normal singleton pregnancies (16-38 weeks' gestation). Single Doppler ultrasound cardiac cycle images of 25 cases were selected, triplicated and randomized (n = 75). Six senior observers, unaware of the repetition of images, manually calculated MPI for each waveform and the results were compared with automation. Intraobserver repeatability and interobserver reproducibility were assessed using intraclass correlation coefficients (ICCs) and 95% CI. The agreement between each observer's manual MPI measurements and corresponding automated measurements was evaluated using Bland-Altman plots and ICCs with 95% CI. The degree of variation between experts in the classification of fetal MPI waveform quality was assessed using individual cardiac cycle left MPI images previously classified by two authors as 'optimal', 'suboptimal' or 'unacceptable', with 30 images selected for each quality group. Ten images in each category were duplicated and the resulting 120 images were randomized and then classified online by five observers. The kappa statistic (κ) was used to demonstrate interobserver and intraobserver agreement and agreement of classifications by the five observers. RESULTS The automated measurement software returned the same value for any given image, resulting in an ICC of 1.00. Manual measurements had intraobserver repeatability ICC values ranging from 0.69 to 0.97, and the interobserver reproducibility ICC was 0.78. Comparison of automated vs manual MPI absolute measurements for each observer gave ICCs ranging from 0.77 to 0.96. Interobserver image quality classification agreement gave k = 0.69 (P < 0.001), and the intraobserver agreement was variable (κ ranging from 0.40 to 0.81). CONCLUSIONS Automated fetal MPI provides superior repeatability and reproducibility to manual methodology. Additionally, experts vary significantly when classifying suitability of fetal MPI waveforms. Automated MPI may facilitate clinical translation by removing human subjectivity. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- A W Welsh
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Randwick, Sydney, New South Wales, Australia.
- School of Women's & Children's Health, University of New South Wales, Sydney, New South Wales, Australia.
| | - P Maheshwari
- Faculty of Medicine, University of New South Wales, Sydney, New South Wales, Australia
| | - J Wang
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - A Henry
- Faculty of Medicine, University of New South Wales, Sydney, New South Wales, Australia
| | - D Chang
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - F Crispi
- Maternal-Fetal Medicine, Hospital Clinica Barcelona, Barcelona, Spain
| | | | - E Hernandez-Andrade
- Department of Obstetrics and Gynecology, Fetal Medicine Unit, Wayne State University School of Medicine Detroit, Detroit, MI, USA
| | - N Meriki
- School of Medicine, King Saud University, Riyadh, Saudi Arabia
| | - S Redmond
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - S Yagel
- Obstetrics and Gynaecology, Hadassah University Hospital, Mt Scopus, Jerusalem, Israel
| |
Collapse
|
12
|
Wang J, Henry A, Welsh AW, Redmond SJ. Automated cardiac time interval measurement for Modified Myocardial Performance Index calculation of right ventricle. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7288-91. [PMID: 26737974 DOI: 10.1109/embc.2015.7320074] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The Modified Myocardial Performance Index (Mod-MPI) has sparked great interest as a parameter for fetal cardiac function assessment. However, measurement of this index requires expertise and its clinical application might be limited, owing to its poor repeatability. Research groups have been investigating left Mod-MPI (that is, Mod-MPI from left ventricle valve events), and an automated algorithm has been developed for left Mod-MPI calculation in our previous study. Right MPI is also important as it becomes abnormal earlier than left MPI in some pathologies; however, for use across the gestational age spectrum, it requires two-image acquisition. This paper presents an automated method to detect valve movements during atrioventricular outflow and ventricular inflow and to further calculate the time intervals required for right MPI calculation. Ninety pulsed-wave Doppler ultrasound images of the right ventricle in fetuses, forty-five showing outflow and forty-five inflow, were analyzed to automatically detect the valve clicks generated by tricuspid valve movement in inflow waves, and pulmonary valve movement in outflow waves. The morphological characteristics of waves were combined with intensity information to locate clicks. This automated method can detect valve movement events with a high positive predictive value (96.20-98.96%) and sensitivity (97.95-100.00%), using manual annotation from an expert ultrasonographer as the gold standard for evaluation.
Collapse
|
13
|
Henry A, Welsh AW. Monitoring intrahepatic cholestasis of pregnancy using the fetal myocardial performance index: a cohort study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2015; 46:571-578. [PMID: 25516144 DOI: 10.1002/uog.14769] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 12/06/2014] [Accepted: 12/08/2014] [Indexed: 06/04/2023]
Abstract
OBJECTIVE To investigate use of the fetal myocardial performance index (MPI) in assessing intrahepatic cholestasis of pregnancy (ICP). METHODS This was a cohort study including cross-sectional and longitudinal data from 31 women with ICP recruited from June 2012 to March 2014. Fetal left, right and delta MPI (LMPI, RMPI and DMPI), and routine measures of fetal growth and wellbeing, were obtained at each ultrasound examination. Results were evaluated with respect to gestational age (GA)-adjusted reference intervals, level of maternal serum bile acid (SBA) and fetal outcome. Lower SBA (≥ 7.5 and < 40 μmol/L) and high SBA (≥ 40 μmol/L) subgroups of cases were defined for the analysis. RESULTS A total of 51 ultrasound examinations were performed in 33 fetuses. The mean LMPI, and means of its isovolumetric relaxation time (IRT) and isovolumetric contraction time (ICT) components were significantly higher in all subgroups of cases of ICP relative to the normal reference mean. Considering only the first examination in each case of ICP, IRT was significantly more prolonged in the high SBA group (n = 10) in comparison to the lower SBA group (n = 23) (52.7 ± 8.0 ms vs 47.3 ± 4.8 ms, P = 0.02), and both IRT (r = 0.538, P = 0.001) and LMPI (r = 0.367, P = 0.036) were significantly correlated with SBA concentration. The proportion of high SBA cases with LMPI, RMPI or DMPI > 2 SD above the GA-adjusted reference mean was not significantly greater than for the lower SBA group. On analysis of all data from those cases with more than one examination, no significant correlation was found between SBA concentration and any of the MPI variables. CONCLUSIONS LMPI values increase above the population GA-adjusted mean in cases of ICP, particularly amongst women with higher SBA. A significant correlation between IRT and LMPI at initial examination and increasing SBA concentration was found. A future multicenter prospective study may clarify the prognostic utility of MPI in ICP.
Collapse
Affiliation(s)
- A Henry
- School of Women's and Children's Health, UNSW Medicine, Randwick, NSW, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Randwick, NSW, Australia
- Women's and Children's Health, St George Hospital, Kogarah, NSW, Australia
- Australian Centre for Perinatal Science, UNSW Medicine, Randwick, NSW, Australia
| | - A W Welsh
- School of Women's and Children's Health, UNSW Medicine, Randwick, NSW, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Randwick, NSW, Australia
- Australian Centre for Perinatal Science, UNSW Medicine, Randwick, NSW, Australia
| |
Collapse
|
14
|
Maheshwari P, Henry A, Welsh AW. The Fetal Modified Myocardial Performance Index: Is Automation the Future? BIOMED RESEARCH INTERNATIONAL 2015; 2015:215910. [PMID: 26185751 PMCID: PMC4491561 DOI: 10.1155/2015/215910] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2014] [Accepted: 09/28/2014] [Indexed: 11/30/2022]
Abstract
The fetal modified myocardial performance index (Mod-MPI) is a noninvasive, pulsed-wave Doppler-derived measure of global myocardial function. This review assesses the progress in technical refinements of its measurement and the potential for automation to be the crucial next step. The Mod-MPI is a ratio of isovolumetric to ejection time cardiac time intervals, and the potential for the left ventricular Mod-MPI as a tool to clinically assess fetal cardiac function is well-established. However, there are wide variations in published reference ranges, as (1) a standardised method of selecting cardiac time intervals used in Mod-MPI calculation has not been established; (2) cardiac time interval measurement currently requires manual, inherently subjective placement of callipers on Doppler ultrasound waveforms; and (3) ultrasound machine settings and ultrasound system type have been found to affect Mod-MPI measurement. Collectively these factors create potential for significant inter- and intraobserver measurement variability. Automated measurement of the Mod-MPI may be the next key development which propels the Mod-MPI into routine clinical use. A novel automated system of Mod-MPI measurement is briefly presented and its implications for the future of the Mod-MPI in fetal cardiology are discussed.
Collapse
Affiliation(s)
- Priya Maheshwari
- Faculty of Medicine, School of Women's & Children's Health, University of New South Wales, Sydney, NSW 2052, Australia
| | - Amanda Henry
- Faculty of Medicine, School of Women's & Children's Health, University of New South Wales, Sydney, NSW 2052, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Locked Bag 2000, Barker Street, Randwick, NSW 2031, Australia
- Women's and Children's Health, St George Hospital, Kogarah, NSW 2217, Australia
- Australian Centre for Perinatal Science, University of New South Wales, Sydney, NSW 2052, Australia
| | - Alec W. Welsh
- Faculty of Medicine, School of Women's & Children's Health, University of New South Wales, Sydney, NSW 2052, Australia
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Locked Bag 2000, Barker Street, Randwick, NSW 2031, Australia
- Australian Centre for Perinatal Science, University of New South Wales, Sydney, NSW 2052, Australia
| |
Collapse
|
15
|
Welsh AW, Henry A, Meriki N, Mahajan A, Wu L, Alphonse J. Is There a Measurable Difference between the Left and Right Modified Myocardial Performance Indices, and Does This Change to Reflect Unilateral Myocardial Dysfunction in Pathology? Fetal Diagn Ther 2015; 38:288-95. [DOI: 10.1159/000381709] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Accepted: 03/12/2015] [Indexed: 11/19/2022]
Abstract
Introduction: Fetal cardiac dysfunction may manifest itself unilaterally as right and left ventricles differing in design, function and load, measurable as differing in myocardial performance indices (MPIs). We wished to define this difference (‘delta-MPI' or DMPI), present its normal range and pilot its use in pathological pregnancy. Material and Methods: Prospective cross-sectional study of 324 normal singleton fetuses (16-38 weeks of gestation). Left and right modified MPI (LMPI and RMPI) were performed during a single examination using the ‘peak' valve click technique. Thirty-seven pathological singleton and monochorionic diamniotic twin pregnancies were compared as pilot data. Results: Modified MPIs (mean ± SD) were 0.45 ± 0.06 (LMPI) and 0.47 ± 0.09 (RMPI), being similar at 18 weeks' gestation with DMPI increasing slightly throughout pregnancy (0.02 ± 0.08). Both singleton intrauterine growth restriction (IUGR) and recipient twin-twin transfusion syndrome (TTTS) showed significantly elevated RMPI, LMPI and DMPI, most pronounced for DMPI (450 and 500% increase, respectively; p < 0.01). DMPI acquisition rates were 83.3% normal and 87.0% pathological. Discussion: We demonstrate for the first time differing intrafetal LMPI and RMPI in a large gestational cohort, with this difference increasing with gestational age. Pilot data confirm the potential for DMPI as a tool to assess unilateral myocardial function in singleton IUGR and recipient twins in TTTS, and further studies are under way to evaluate its clinical utility.
Collapse
|
16
|
Mahajan A, Henry A, Meriki N, Hernandez-Andrade E, Crispi F, Wu L, Welsh AW. The (Pulsed-Wave) Doppler Fetal Myocardial Performance Index: Technical Challenges, Clinical Applications and Future Research. Fetal Diagn Ther 2015; 38:1-13. [DOI: 10.1159/000363181] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2014] [Accepted: 04/24/2014] [Indexed: 11/19/2022]
Abstract
Functional cardiovascular assessment is becoming an increasingly important tool in the study of fetal pathology. The myocardial performance index (MPI) is a parameter measuring global myocardial function. Since its introduction, several studies have proposed methods to improve its reproducibility and have constructed normative reference ranges. Fetal heart evaluation using the MPI is technically challenging, requiring specific training and expertise, and a consensus has yet to be reached on the method of delineating the time periods used to calculate the index. Despite these limitations, it has been shown to be a useful and highly sensitive parameter of dysfunction in a number of fetal pathologies. Further research is warranted into the effect of pathology on MPI, parameters of unilateral cardiac strain that utilise MPI, and automation of the MPI to encourage incorporation of the MPI as a useful tool in clinical practice.
Collapse
|
17
|
Wang J, Henry A, Welsh AW, Redmond SJ. Automated fetal cardiac valve movement detection for modified myocardial performance index calculation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:1063-6. [PMID: 25570145 DOI: 10.1109/embc.2014.6943777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The Modified Myocardial Performance Index (Mod-MPI) is becoming an important index in fetal cardiac function evaluation. However, the current method for Mod-MPI calculation can be time-consuming and demonstrates poor inter-operator repeatability. This paper presents an automated method for detecting the opening and closing events of fetal cardiac valves with the aim of automating the Mod-MPI calculation. Fifty-four Doppler ultrasound images, showing blood inflow and outflow for the left ventricle, are analyzed to attempt to automatically detect the timings of a total of 905 opening and closing events for both aortic and mitral valves. Timings are found according to the morphological characteristics of waveforms as well as intensity information of images. The proposed method can detect the four valve movement events with high sensitivity (95.60-98.64%) and precision (96.85-100.00%). Results are verified by comparison with manual annotation of same images from an expert.
Collapse
|
18
|
Meriki N, Henry A, Sanderson J, Majajan A, Wu L, Welsh AW. Development of Normal Gestational Ranges for the Right Myocardial Performance Index in the Australian Population with Three Alternative Caliper Placements. Fetal Diagn Ther 2014; 36:272-81. [DOI: 10.1159/000362388] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2013] [Accepted: 03/18/2014] [Indexed: 11/19/2022]
|
19
|
Lobmaier SM, Cruz-Lemini M, Valenzuela-Alcaraz B, Ortiz JU, Martinez JM, Gratacos E, Crispi F. Influence of equipment and settings on myocardial performance index repeatability and definition of settings to achieve optimal reproducibility. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2014; 43:632-639. [PMID: 24639072 DOI: 10.1002/uog.13365] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 02/28/2014] [Indexed: 06/03/2023]
Abstract
OBJECTIVE To compare left myocardial performance index (MPI) values and reproducibility using different settings and ultrasound equipment in order to standardize optimal machine settings. METHODS Left MPI was prospectively evaluated by one observer performing conventional Doppler in 62 fetuses (28-36 weeks of gestational age) using different settings (changing sweep speed, gain and wall motion filter (WMF)) and two different ultrasound devices (Siemens Antares, Siemens; Voluson 730 Expert, GE Medical Systems). Intraclass coefficients of agreement (ICCs) were calculated using Bland-Altman analysis. RESULTS Using baseline settings on the Siemens, mean (SD) MPI was 0.44 (0.05) with an ICC of 0.81. Decreasing the sweep speed resulted in decreasing average MPI values (0.43) and decreasing ICC (0.61). Lowering gain also influenced average MPI values (0.46) and ICC (0.76). Raising gain resulted in similar MPI values (0.45) with better ICC (0.90) compared with baseline settings. Raising wall motion filter (WMF) provided the best ICC (0.94) compared with the other settings. Changing the ultrasound equipment resulted in an ICC of 0.64. The optimal settings to achieve the highest reproducibility in measurement of MPI were sweep speed 8, gain 60 dB and WMF 281 Hz for Siemens Antares and sweep speed 5, gain -10 dB and WMF 210 Hz for Voluson 730 Expert. CONCLUSION Changing ultrasound settings or equipment may affect the calculation and repeatability of measurement of MPI values. Strict standardization of methods decreases the variability of this parameter for fetal cardiac function assessment.
Collapse
Affiliation(s)
- S M Lobmaier
- BCNatal-Barcelona Center for Maternal-Fetal and Neonatal Medicine (Hospital Clínic and Hospital Sant Joan de Deu), IDIBAPS, University of Barcelona, and Centre for Biomedical Research on Rare Diseases (CIBER-ER), Barcelona, Spain; Frauenklinik und Poliklinik, Technische Universität München, Munich, Germany
| | | | | | | | | | | | | |
Collapse
|
20
|
Lee MY, Won HS, Jeon EJ, Yoon HC, Choi JY, Hong SJ, Kim MJ. Feasibility of using auto Mod-MPI system, a novel technique for automated measurement of fetal modified myocardial performance index. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2014; 43:640-645. [PMID: 24214891 DOI: 10.1002/uog.13247] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 09/11/2013] [Accepted: 10/28/2013] [Indexed: 06/02/2023]
Abstract
OBJECTIVES To evaluate the reproducibility of measurement of the fetal left modified myocardial performance index (Mod-MPI) determined using a novel automated system. METHODS This was a prospective study of 116 ultrasound examinations from 110 normal singleton pregnancies at 12 + 1 to 37 + 1 weeks' gestation. Two experienced operators each measured the left Mod-MPI twice manually and twice automatically using the Auto Mod-MPI system. Intra- and interoperator reproducibility were assessed using intraclass correlation coefficients (ICCs) and the manual and automated measurements obtained by the more experienced operator were compared using Bland-Altman plots and ICCs. RESULTS Both operators successfully measured the left Mod-MPI in all cases using the Auto Mod-MPI system. For both operators, intraoperator reproducibility was higher when performing automated measurements (ICC = 0.967 and 0.962 for Operators 1 and 2, respectively) than when performing manual measurements (ICC = 0.857 and 0.856 for Operators 1 and 2, respectively). Interoperator agreement was also better for automated than for manual measurements (ICC = 0.930 vs 0.723, respectively). There was good agreement between the automated and manual values measured by the more experienced operator. CONCLUSIONS The Auto Mod-MPI system is a reliable technique for measuring fetal left Mod-MPI and demonstrates excellent reproducibility.
Collapse
Affiliation(s)
- M-Y Lee
- Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| | | | | | | | | | | | | |
Collapse
|