Spurway J, Logan P, Pak SC, Nielsen S. Reference ranges for the intra-amniotic umbilical cord vein diameter, peak velocity and blood flow in a regional NSW population.
Australas J Ultrasound Med 2017;
20:155-162. [PMID:
34760489 PMCID:
PMC8409896 DOI:
10.1002/ajum.12060]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
AIM
To construct gestational age (GA)-related reference ranges of the intra-amniotic umbilical cord vein (UCV) diameter, peak velocity (PV) and blood flow (Qucv) using a Central West New South Wales population.
MATERIALS AND METHODS
This was a prospective, quasi-experimental study of low risk, singleton pregnancies (n = 321) between 16 and 42 weeks of gestation. Participation was voluntary following informed consent. The UCV diameter and PV were measured using B mode and duplex Doppler respectively, and Qucv calculated. Percentile values and reference range graphs were established using quantile regression modelling in R statistical software. Intraclass correlation coefficients (ICCs) were calculated to assess the intra and intersonographer reliability.
RESULTS
Reference ranges for the UCV diameter, PV and Qucv were established and graphed. All three UCV measurements increased with advancing GA, with both diameter and Qucv exhibiting a decline in the late third trimester. The intrasonographer and intersonographer ICCs for the UCV diameter and PV showed almost perfect agreement within and between sonographers.
CONCLUSION
Gestational age-related reference ranges for the UCV diameter, PV and Qucv were developed using quantile regression from a cohort of low risk, singleton pregnancies in Central West NSW. These reference ranges have the potential to assist in the diagnosis and monitoring of fetal growth restriction.
Collapse