1
|
Simcock IC, Shelmerdine SC, Hutchinson JC, Sebire NJ, Arthurs OJ. Body weight-based iodinated contrast immersion timing for human fetal postmortem microfocus computed tomography. BJR Open 2024; 6:tzad006. [PMID: 38352185 PMCID: PMC10860501 DOI: 10.1093/bjro/tzad006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/27/2023] [Accepted: 10/13/2023] [Indexed: 02/16/2024] Open
Abstract
Objectives The aim of this study was to evaluate the length of time required to achieve full iodination using potassium tri-iodide as a contrast agent, prior to human fetal postmortem microfocus computed tomography (micro-CT) imaging. Methods Prospective assessment of optimal contrast iodination was conducted across 157 human fetuses (postmortem weight range 2-298 g; gestational age range 12-37 weeks), following micro-CT imaging. Simple linear regression was conducted to analyse which fetal demographic factors could produce the most accurate estimate for optimal iodination time. Results Postmortem body weight (r2 = 0.6435) was better correlated with iodination time than gestational age (r2 = 0.1384), producing a line of best fit, y = [0.0304 × body weight (g)] - 2.2103. This can be simplified for clinical use whereby immersion time (days) = [0.03 × body weight (g)] - 2.2. Using this formula, for example, a 100-g fetus would take 5.2 days to reach optimal contrast enhancement. Conclusions The simplified equation can now be used to provide estimation times for fetal contrast preparation time prior to micro-CT imaging and can be used to manage service throughput and parental expectation for return of their fetus. Advances in knowledge A simple equation from empirical data can now be used to estimate preparation time for human fetal postmortem micro-CT imaging.
Collapse
Affiliation(s)
- Ian C Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
| | - Susan C Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
| | - John Ciaran Hutchinson
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
- Department of Histopathology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
| | - Neil J Sebire
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
- Department of Histopathology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
| | - Owen J Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
| |
Collapse
|
2
|
An P, Song L, Song P, Zhang J, Lin Y, Feng G, Liu J. Exploring the Role of Modified Vascular Anatomical Molding (MVAM) in Prenatal Diagnosis Teaching and Prognosis Prediction of Fetal Complex Congenital Heart Disease (CCHD): A Preliminary Study. Int J Gen Med 2023; 16:3229-3245. [PMID: 37546241 PMCID: PMC10403051 DOI: 10.2147/ijgm.s421751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 07/26/2023] [Indexed: 08/08/2023] Open
Abstract
Objective The present study aimed to explore the role of modified vascular anatomical molding (MVAM) in prenatal diagnosis teaching and prognosis prediction of fetal complex congenital heart disease (CCHD). Methods Step 1, MVAM method was used to cast the micro-blood vessels and trachea of 52 CCHD specimens. Subsequently, 52 MVAMs were analyzed and compared with the prenatal ultrasound to summarize their characteristics, misdiagnosis and MVAM's teaching role. Step 2, the surgical and follow-up data of 206 CCHD cases were retrospectively analyzed. Cases that evolved into critical illnesses or died within 1-3 years after surgery (poor prognosis) were classified into the study group (n = 77) and those with good prognosis into the control group (n = 129), which were split into the training set and the test set in the ratio 7:3 based on the time cut-off. In the training set, the prognosis of CCHD was predicted using the MVAM anatomical soft markers (distortion and narrowing of aorta/pulmonary artery, right ventricular infundibulum, etc.) and the decision curve analysis (DCA) performed. The model was validated using the test set, and a nomogram was finally established. Results It was observed that all 52 CCHD cases were confirmed using MVAM. A total of 91 cardiac malformations were recorded, among which 41 malformations were misdiagnosed, and 29 malformations were missed by the prenatal echocardiography. The MVAM method has a good teaching/feedback effect on prenatal diagnosis. The combined model exhibited a higher predictive performance in the training- and test-set. Its high clinical net benefit was proved by DCA. Additionally, the nomogram established using the combined model received a favorable response in clinical practice. Conclusion The research results indicated that MVAM improved the prenatal diagnosis teaching and training performance. The combined model established based on MVAM anatomical soft markers can offer a high clinical significance for prognosis prediction of CCHD.
Collapse
Affiliation(s)
- Peng An
- Department of Radiology, Xiangyang No.1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
- Hubei Provincial Clinical Research Center for Accurate Fetus Malformation Diagnosis, Hubei University of Medicine, Xiangyang, Hubei Province, 441000, People’s Republic of China
| | - Lina Song
- Department of Radiology, Xiangyang No.1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
| | - Ping Song
- Department of Obstetrics and Gynecology, Xiangyang No. 1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
| | - Junyan Zhang
- Department of Radiology, Xiangyang No.1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
- Department of Obstetrics and Gynecology, Xiangyang No. 1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
| | - Yong Lin
- Department of Radiology, Xiangyang No.1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
- Department of Obstetrics and Gynecology, Xiangyang No. 1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
| | - Guoyan Feng
- Department of Radiology, Xiangyang No.1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
| | - Junjie Liu
- Department of Obstetrics and Gynecology, Xiangyang No. 1 People’s Hospital, Hubei University of Medicine, Xiangyang, 441000, People’s Republic of China
| |
Collapse
|
3
|
Simcock IC, Lamouroux A, Sebire NJ, Shelmerdine SC, Arthurs OJ. Less-invasive autopsy for early pregnancy loss. Prenat Diagn 2023; 43:937-949. [PMID: 37127547 DOI: 10.1002/pd.6361] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 05/03/2023]
Abstract
Autopsy investigations provide valuable information regarding fetal death that can assist in the parental bereavement process, and influence future pregnancies, but conventional autopsy is often declined by parents because of its invasive approach. This has led to the development of less-invasive autopsy investigations based on imaging technology to provide a more accessible and acceptable choice for parents when investigating their loss. Whilst the development and use of more conventional clinical imaging techniques (radiographs, CT, MRI, US) are well described in the literature for fetuses over 20 weeks of gestational age, these investigations have limited diagnostic accuracy in imaging smaller fetuses. Techniques such as ultra-high-field MRI (>3T) and micro-focus computed tomography have been shown to have higher diagnostic accuracy whilst still being acceptable to parents. By further developing and increasing the availability of these more innovative imaging techniques, parents will be provided with a greater choice of acceptable options to investigate their loss, which may in turn increase their uptake. We provide a narrative review focussing on the development of high-resolution, non-invasive imaging techniques to evaluate early gestational pregnancy loss.
Collapse
Affiliation(s)
- Ian C Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Audrey Lamouroux
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Obstetrical Gynaecology Department, Nîmes University Hospital, Nîmes, France
- Clinical Genetics Department, Montpellier University Hospital, Montpellier, France
- ICAR Research Team, LIRMM, CNRS and Charles Coulomb Laboratory, UMR 5221 CNRS-UM, BNIF User Facility Imaging, University of Montpellier, Nîmes and Montpellier, Montpellier, France
| | - Neil J Sebire
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children, London, UK
| | - Susan C Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Owen J Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| |
Collapse
|
4
|
Docter D, Dawood Y, Jacobs K, Hagoort J, Oostra RJ, van den Hoff MJB, Arthurs OJ, de Bakker BS. Microfocus computed tomography for fetal postmortem imaging: an overview. Pediatr Radiol 2023; 53:632-639. [PMID: 36169668 PMCID: PMC10027643 DOI: 10.1007/s00247-022-05517-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 07/18/2022] [Accepted: 09/06/2022] [Indexed: 10/14/2022]
Abstract
Over the last few years, fetal postmortem microfocus computed tomography (micro-CT) imaging has increased in popularity for both diagnostic and research purposes. Micro-CT imaging could be a substitute for autopsy, particularly in very early gestation fetuses for whom autopsy can be technically challenging and is often unaccepted by parents. This article provides an overview of the latest research in fetal postmortem micro-CT imaging with a focus on diagnostic accuracy, endovascular staining approaches, placental studies and the reversibility of staining. It also discusses new methods that could prove helpful for micro-CT of larger fetuses. While more research is needed, contrast-enhanced micro-CT has the potential to become a suitable alternative to fetal autopsy. Further research using this novel imaging tool could yield wider applications, such as its practise in imaging rare museum specimens.
Collapse
Affiliation(s)
- Daniël Docter
- Department of Medical Biology, Amsterdam UMC at University of Amsterdam, Amsterdam, The Netherlands
| | - Yousif Dawood
- Department of Medical Biology, Amsterdam UMC at University of Amsterdam, Amsterdam, The Netherlands
- Department of Obstetrics and Gynecology, Amsterdam UMC at University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
- Amsterdam Reproduction and Development Research Institute, Amsterdam, The Netherlands
| | - Karl Jacobs
- Department of Medical Biology, Amsterdam UMC at University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Reproduction and Development Research Institute, Amsterdam, The Netherlands
- Department of Oral Pain and Dysfunction, Functional Anatomy, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU University Amsterdam, Amsterdam, The Netherlands
| | - Jaco Hagoort
- Department of Medical Biology, Amsterdam UMC at University of Amsterdam, Amsterdam, The Netherlands
| | - Roelof-Jan Oostra
- Department of Medical Biology, Amsterdam UMC at University of Amsterdam, Amsterdam, The Netherlands
| | - Maurice J B van den Hoff
- Department of Medical Biology, Amsterdam UMC at University of Amsterdam, Amsterdam, The Netherlands
- Amsterdam Reproduction and Development Research Institute, Amsterdam, The Netherlands
| | - Owen J Arthurs
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
- National Institute for Health Research, Great Ormond Street Hospital Biomedical Research Center, London, UK
| | - Bernadette S de Bakker
- Department of Obstetrics and Gynecology, Amsterdam UMC at University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.
- Amsterdam Reproduction and Development Research Institute, Amsterdam, The Netherlands.
- Department of Pediatric Surgery, Erasmus MC - Sophia Children's Hospital, University Medical Center Rotterdam, Rotterdam, The Netherlands.
| |
Collapse
|
5
|
Papazoglou AS, Karagiannidis E, Liatsos A, Bompoti A, Moysidis DV, Arvanitidis C, Tsolaki F, Tsagkaropoulos S, Theocharis S, Tagarakis G, Michaelson JS, Herrmann MD. Volumetric Tissue Imaging of Surgical Tissue Specimens Using Micro-Computed Tomography: An Emerging Digital Pathology Modality for Nondestructive, Slide-Free Microscopy-Clinical Applications of Digital Pathology in 3 Dimensions. Am J Clin Pathol 2023; 159:242-254. [PMID: 36478204 DOI: 10.1093/ajcp/aqac143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 10/14/2022] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVES Micro-computed tomography (micro-CT) is a novel, nondestructive, slide-free digital imaging modality that enables the acquisition of high-resolution, volumetric images of intact surgical tissue specimens. The aim of this systematic mapping review is to provide a comprehensive overview of the available literature on clinical applications of micro-CT tissue imaging and to assess its relevance and readiness for pathology practice. METHODS A computerized literature search was performed in the PubMed, Scopus, Web of Science, and CENTRAL databases. To gain insight into regulatory and financial considerations for performing and examining micro-CT imaging procedures in a clinical setting, additional searches were performed in medical device databases. RESULTS Our search identified 141 scientific articles published between 2000 and 2021 that described clinical applications of micro-CT tissue imaging. The number of relevant publications is progressively increasing, with the specialties of pulmonology, cardiology, otolaryngology, and oncology being most commonly concerned. The included studies were mostly performed in pathology departments. Current micro-CT devices have already been cleared for clinical use, and a Current Procedural Terminology (CPT) code exists for reimbursement of micro-CT imaging procedures. CONCLUSIONS Micro-CT tissue imaging enables accurate volumetric measurements and evaluations of entire surgical specimens at microscopic resolution across a wide range of clinical applications.
Collapse
Affiliation(s)
| | - Efstratios Karagiannidis
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Alexandros Liatsos
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Andreana Bompoti
- Diagnostic Imaging, Peterborough City Hospital, North West Anglia NHS Foundation Trust, Peterborough, UK
| | - Dimitrios V Moysidis
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Christos Arvanitidis
- Institute of Marine Biology, Biotechnology and Aquaculture, Hellenic Centre for Marine Research, Heraklion, Crete, Greece.,LifeWatch ERIC, Sector II-II, Seville, Spain
| | - Fani Tsolaki
- Department of Cardiothoracic Surgery, AHEPA University Hospital, Thessaloniki, Greece
| | | | - Stamatios Theocharis
- First Department of Pathology, National and Kapoditrian University of Athens, Athens, Greece
| | - Georgios Tagarakis
- Department of Cardiothoracic Surgery, AHEPA University Hospital, Thessaloniki, Greece
| | - James S Michaelson
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Markus D Herrmann
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
6
|
A High-Fidelity Three-Dimensional Computational Model of a Patient with Hypertrophic Cardiomyopathy. CASE 2022; 6:350-354. [PMID: 36247372 PMCID: PMC9556921 DOI: 10.1016/j.case.2022.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Echocardiography and CMR are used for diagnosis of HCM. Learning echocardiography requires advanced and repetitive training. A 3D model can enhance understanding of cardiac anatomy and pathophysiology.
Collapse
|
7
|
Franchetti G, Viel G, Fais P, Fichera G, Cecchin D, Cecchetto G, Giraudo C. Forensic applications of micro-computed tomography: a systematic review. Clin Transl Imaging 2022. [DOI: 10.1007/s40336-022-00510-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Abstract
Purpose
The aim of this systematic review was to provide a comprehensive overview of micro-CT current applications in forensic pathology, anthropology, odontology, and neonatology.
Methods
A bibliographic research on the electronic databases Pubmed and Scopus was conducted in the time frame 01/01/2001–31/12/2021 without any language restrictions and applying the following free-text search strategy: “(micro-computed tomography OR micro-CT) AND (forensic OR legal)”. The following inclusion criteria were used: (A) English language; (B) Application of micro-CT to biological and/or non-biological materials to address at least one forensic issue (e.g., age estimation, identification of post-mortem interval). The papers selected by three independent investigators have been then classified according to the investigated materials.
Results
The bibliographic search provided 651 records, duplicates excluded. After screening for title and/or abstracts, according to criteria A and B, 157 full-text papers were evaluated for eligibility. Ninety-three papers, mostly (64) published between 2017 and 2021, were included; considering that two papers investigated several materials, an overall amount of 99 classifiable items was counted when referring to the materials investigated. It emerged that bones and cartilages (54.55%), followed by teeth (13.13%), were the most frequently analyzed materials. Moreover, micro-CT allowed the collection of structural, qualitative and/or quantitative information also for soft tissues, fetuses, insects, and foreign materials.
Conclusion
Forensic applications of micro-CT progressively increased in the last 5 years with very promising results. According to this evidence, we might expect in the near future a shift of its use from research purposes to clinical forensic cases.
Collapse
|
8
|
Sandrini C, Lombardi C, Zambelli V, Zanarotti R, Raffaelli R, Franchi M, Papadopoulos N, Di Pace C, Hoxha S, Murari A, Chamitava L, Zanolin M, Faggian G, Ribichini F, Rossetti L, Luciani G. What can we learn from systematic segmental analysis of fetal heart by postmortem micro-CT: Is it time to change approach? INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE 2022. [DOI: 10.1016/j.ijcchd.2021.100308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
9
|
Sandrini C, Boito S, Lombardi CM, Lombardi S. Postmortem Micro-CT of Human Fetal Heart-A Systematic Literature Review. J Clin Med 2021; 10:jcm10204726. [PMID: 34682849 PMCID: PMC8539069 DOI: 10.3390/jcm10204726] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 10/06/2021] [Accepted: 10/09/2021] [Indexed: 12/20/2022] Open
Abstract
Micro-computed tomography (CT) is a non-invasive alternative to conventional macroscopic dissection for the evaluation of human fetal cardiac anatomy. This paper aims to systematically review the literature regarding the use of micro-CT to examine human fetal hearts, to illustrate its educational and research implications and to explain its possible directions for the future. A systematic literature review was conducted following the PRISMA statement to identify publications concerning micro-CT applications for the isolated human fetal heart. The search strategy identified nine eligible studies. Micro-CT is technically feasible for postmortem examination of the human fetal heart coming from early and late termination of pregnancy. It reaches high diagnostic accuracy, and it seems to perform better than autopsy in small samples or in the case of early termination of pregnancy. Applications derived from micro-CT allow multiple off-time evaluations and interdisciplinary comparisons for educational purposes and research perspectives in biological and bioengineering domains.
Collapse
Affiliation(s)
- Camilla Sandrini
- Division of Cardiology, Department of Medicine, University of Verona, 37126 Verona, Italy
- Correspondence:
| | - Simona Boito
- Fetal Medicine and Surgery Service, Fondazione IRCCS Ca’ Granda, Ospedale Maggiore Policlinico, 20122 Milan, Italy;
| | | | - Sophie Lombardi
- Department of Diagnostic and Interventional Radiology, Fondazione IRCCS Policlinico San Matteo, 27100 Pavia, Italy;
| |
Collapse
|
10
|
Struksnæs C, Blaas HGK, Eik-Nes SH, Tegnander E, Vogt C. Postmortem Assessment of Isolated Congenital Heart Defects Remains Essential Following Termination of Pregnancy. Pediatr Dev Pathol 2021; 24:422-429. [PMID: 33993792 DOI: 10.1177/10935266211016184] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
OBJECTIVES To investigate the correlation between prenatal ultrasound (US) and autopsy findings in pregnancies terminated due to isolated congenital heart defects (CHDs), including CHDs associated with heterotaxy syndrome. MATERIALS AND METHODS The material consists of 67 fetuses with prenatally detected isolated CHDs or CHDs associated with heterotaxy syndrome at a tertiary center in Norway between 1985 and 2014. The main CHDs were categorized into subdiagnoses of CHDs in accordance with ICD-10. The US and autopsy findings were categorized according to degree of concordance. RESULTS Gestational age at termination was 12 + 0-22 + 6 weeks. Hypoplastic left heart syndrome was the most common main diagnosis among the 67 fetuses (32.8%). There was full agreement between US and autopsy findings in 97.4% (222/228) of all subdiagnoses. The discrepant findings in three fetuses had no influence on the decision to terminate the pregnancy. CONCLUSIONS The correlation was high between prenatal US and postmortem findings in fetuses with isolated CHDs. Meticulous assessment of cardiac anatomy is particularly necessary when the decision to terminate relies on isolated CHDs. The trend of earlier termination challenges verification of diagnoses at autopsy. Consequently, the fetus should be examined at a tertiary center with fetal medicine specialists, pediatric cardiologists and perinatal pathologists.
Collapse
Affiliation(s)
- Camilla Struksnæs
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
| | - Harm-Gerd K Blaas
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway.,National Center for Fetal Medicine, Department of Obstetrics and Gynecology, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Sturla H Eik-Nes
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway.,National Center for Fetal Medicine, Department of Obstetrics and Gynecology, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Eva Tegnander
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway.,National Center for Fetal Medicine, Department of Obstetrics and Gynecology, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Christina Vogt
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway.,Department of Pathology, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
| |
Collapse
|
11
|
Simcock IC, Shelmerdine SC, Langan D, Anna G, Sebire NJ, Arthurs OJ. Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration. BMC Med Imaging 2021; 21:128. [PMID: 34429085 PMCID: PMC8383392 DOI: 10.1186/s12880-021-00658-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 08/01/2021] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Current clinical post-mortem imaging techniques do not provide sufficiently high-resolution imaging for smaller fetuses after pregnancy loss. Post-mortem micro-CT is a non-invasive technique that can deliver high diagnostic accuracy for these smaller fetuses. The purpose of the study is to identify the main predictors of image quality for human fetal post-mortem micro-CT imaging. METHODS Human fetuses were imaged using micro-CT following potassium tri-iodide tissue preparation, and axial head and chest views were assessed for image quality on a Likert scale by two blinded radiologists. Simple and multivariable linear regression models were performed with demographic details, iodination, tissue maceration score and imaging parameters as predictor variables. RESULTS 258 fetuses were assessed, with median weight 41.7 g (2.6-350 g) and mean gestational age 16 weeks (11-24 weeks). A high image quality score (> 6.5) was achieved in 95% of micro-CT studies, higher for the head (median = 9) than chest (median = 8.5) imaging. The strongest negative predictors of image quality were increasing maceration and body weight (p < 0.001), with number of projections being the best positive imaging predictor. CONCLUSIONS High micro-CT image quality score is achievable following early pregnancy loss despite fetal maceration, particularly in smaller fetuses where conventional autopsy may be particularly challenging. These findings will help establish clinical micro-CT imaging services, addressing the need for less invasive fetal autopsy methods.
Collapse
Affiliation(s)
- Ian Craig Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK.
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK.
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK.
| | - Susan Cheng Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Dean Langan
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
| | - Guy Anna
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Neil James Sebire
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children, London, UK
| | - Owen John Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| |
Collapse
|
12
|
Ulm B, Dovjak GO, Scharrer A, Muin DA, Zimpfer D, Prayer D, Weber M, Berger-Kulemann V. Diagnostic quality of 3Tesla postmortem magnetic resonance imaging in fetuses with and without congenital heart disease. Am J Obstet Gynecol 2021; 225:189.e1-189.e30. [PMID: 33662361 DOI: 10.1016/j.ajog.2021.02.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 02/16/2021] [Accepted: 02/18/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND Postmortem confirmation of prenatally diagnosed congenital heart disease after termination of pregnancy and evaluation of potential cardiac defects after spontaneous fetal or neonatal death are essential. Conventional autopsy rates are decreasing, and 1.5Tesla magnetic resonance imaging has demonstrated limited diagnostic accuracy for postmortem cardiovascular assessment. OBJECTIVE This study aimed to evaluate the feasibility and image quality of cardiac 3Tesla postmortem magnetic resonance imaging and to assess its diagnostic accuracy in detecting fetal heart defects compared with conventional autopsy. Secondarily, the study aimed to explore whether clinical factors affect the quality of 3Tesla postmortem magnetic resonance imaging. STUDY DESIGN A total of 222 consecutive fetuses between 12 and 41 weeks' gestation, who underwent 3Tesla postmortem magnetic resonance imaging and conventional autopsy after spontaneous death or termination of pregnancy for fetal malformations, were included. First, 3Tesla postmortem magnetic resonance imaging of each fetus was rated as diagnostic or nondiagnostic for fetal cardiac assessment by 2 independent raters. The image quality of individual cardiac structures was then further evaluated by visual grading analysis. Finally, the presence or absence of a congenital heart defect was assessed by 2 radiologists and compared with autopsy results. RESULTS Overall, 87.8% of 3Tesla postmortem magnetic resonance imaging examinations were rated as diagnostic for the fetal heart. Diagnostic imaging rates of individual cardiac structures at 3Tesla postmortem magnetic resonance imaging ranged from 85.1% (atrioventricular valves) to 94.6% (pericardium), with an interrater agreement of 0.82 (0.78-0.86). Diagnostic imaging of the fetal aortic arch and the systemic veins at 3Tesla postmortem magnetic resonance imaging was possible from 12+5 weeks' gestation onward in 90.1% and 92.3% of cases, respectively. A total of 55 fetuses (24.8%) had at least 1 cardiac anomaly according to autopsy, 164 (73.9%) had a normal heart, and in 3 fetuses (1.4%), autopsy was nondiagnostic for the heart. Considering all examinations rated as diagnostic, 3Tesla postmortem magnetic resonance imaging provided high diagnostic accuracy for the detection of fetal congenital heart defects with a sensitivity of 87.8%, a specificity of 97.9%, and concordance with autopsy of 95.3%. 3Tesla postmortem magnetic resonance imaging was less accurate in young fetuses (<20 weeks compared with ≥20 weeks; P<.001), in fetuses with low birthweight (≤100 g compared with >100 g; P<.001), in cases after spontaneous fetal death (compared with other modes of death; P=.012), in cases with increasing latency between death and 3Tesla postmortem magnetic resonance imaging (P<.001), and in cases in which there was a high degree of maceration (maceration score of 3 compared with a score from 0 to 2; P=.004). CONCLUSION Diagnostic 3Tesla postmortem magnetic resonance imaging assessment of the fetal heart is feasible in most fetuses from 12 weeks' gestation onward. In diagnostic images, sensitivity and, particularly, specificity in the detection of congenital heart disease are high compared with conventional autopsy. Owing to its high diagnostic accuracy, we suggest that 3Tesla postmortem magnetic resonance imaging may serve as a suitable imaging modality with which to direct a targeted conventional autopsy when pathology resources are limited or to provide a virtual autopsy when full autopsy is declined by the parents.
Collapse
Affiliation(s)
- Barbara Ulm
- Division of Obstetrics and Fetomaternal Medicine, Department of Obstetrics and Gynecology, Medical University of Vienna, Vienna, Austria.
| | - Gregor O Dovjak
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Anke Scharrer
- Department of Pathology, Medical University of Vienna, Vienna, Austria
| | - Dana A Muin
- Division of Obstetrics and Fetomaternal Medicine, Department of Obstetrics and Gynecology, Medical University of Vienna, Vienna, Austria
| | - Daniel Zimpfer
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniela Prayer
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Michael Weber
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Vanessa Berger-Kulemann
- Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
13
|
Papazoglou AS, Karagiannidis E, Moysidis DV, Sofidis G, Bompoti A, Stalikas N, Panteris E, Arvanitidis C, Herrmann MD, Michaelson JS, Sianos G. Current clinical applications and potential perspective of micro-computed tomography in cardiovascular imaging: A systematic scoping review. Hellenic J Cardiol 2021; 62:399-407. [PMID: 33991670 DOI: 10.1016/j.hjc.2021.04.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 03/20/2021] [Accepted: 04/20/2021] [Indexed: 02/06/2023] Open
Abstract
Micro-computed tomography (micro-CT) constitutes an emerging imaging technique, which can be utilized in cardiovascular medicine to study in-detail the microstructure of heart and vessels. This paper aims to systematically review the clinical utility of micro-CT in cardiovascular imaging and propose future applications of micro-CT imaging in cardiovascular research. A systematic scoping review was conducted by searching for original studies written in English according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews. Medline, Scopus, ClinicalTrials.gov, and the Cochrane library were systematically searched through December 11, 2020 to identify publications concerning micro-CT applications in cardiovascular imaging. Preclinical-animal studies and case reports were excluded. The Newcastle-Ottawa assessment scale for observational studies was used to evaluate study quality. In total, the search strategy identified 30 studies that report on micro-CT-based cardiovascular imaging and satisfy our eligibility criteria. Across all included studies, the total number of micro-CT scanned specimens was 1,227. Six studies involved postmortem 3D-reconstruction of congenital heart defects, while eleven studies described atherosclerotic vessel (coronary or carotid) characteristics. Thirteen other studies employed micro-CT for the assessment of medical devices (mainly stents or prosthetic valves). In conclusion, micro-CT is a novel imaging modality, effectively adapted for the 3D visualization and analysis of cardiac soft tissues and devices at high spatial resolution. Its increasing use could make significant contributions to our improved understanding of the histopathophysiology of cardiovascular diseases, and, thus, has the potential to optimize interventional procedures and technologies, and ultimately improve patient outcomes.
Collapse
Affiliation(s)
- Andreas S Papazoglou
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, St. Kiriakidi 1, 54636, Thessaloniki, Greece
| | - Efstratios Karagiannidis
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, St. Kiriakidi 1, 54636, Thessaloniki, Greece
| | - Dimitrios V Moysidis
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, St. Kiriakidi 1, 54636, Thessaloniki, Greece
| | - Georgios Sofidis
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, St. Kiriakidi 1, 54636, Thessaloniki, Greece
| | | | - Nikolaos Stalikas
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, St. Kiriakidi 1, 54636, Thessaloniki, Greece
| | - Eleftherios Panteris
- Biomic_AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center, B1.4, Thessaloniki, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001, Greece
| | - Christos Arvanitidis
- Institute of Marine Biology, Biotechnology and Aquaculture (IMBBC), Hellenic Centre for Marine Research (HCMR), Heraklion, Crete, 70013, Greece; LifeWatch ERIC, Sector II-II, Plaza de España, 41071, Seville, Spain
| | - Markus D Herrmann
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - James S Michaelson
- Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - Georgios Sianos
- First Department of Cardiology, AHEPA University Hospital, Aristotle University of Thessaloniki, St. Kiriakidi 1, 54636, Thessaloniki, Greece.
| |
Collapse
|
14
|
Simcock IC, Shelmerdine SC, Hutchinson JC, Sebire NJ, Arthurs OJ. Human fetal whole-body postmortem microfocus computed tomographic imaging. Nat Protoc 2021; 16:2594-2614. [PMID: 33854254 DOI: 10.1038/s41596-021-00512-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 01/05/2021] [Indexed: 02/02/2023]
Abstract
Perinatal autopsy is the standard method for investigating fetal death; however, it requires dissection of the fetus. Human fetal microfocus computed tomography (micro-CT) provides a generally more acceptable and less invasive imaging alternative for bereaved parents to determine the cause of early pregnancy loss compared with conventional autopsy techniques. In this protocol, we describe the four main stages required to image fetuses using micro-CT. Preparation of the fetus includes staining with the contrast agent potassium triiodide and takes 3-19 d, depending on the size of the fetus and the time taken to obtain consent for the procedure. Setup for imaging requires appropriate positioning of the fetus and takes 1 h. The actual imaging takes, on average, 2 h 40 min and involves initial test scans followed by high-definition diagnostic scans. Postimaging, 3 d are required to postprocess the fetus, including removal of the stain, and also to undertake artifact recognition and data transfer. This procedure produces high-resolution isotropic datasets, allowing for radio-pathological interpretations to be made and long-term digital archiving for re-review and data sharing, where required. The protocol can be undertaken following appropriate training, which includes both the use of micro-CT techniques and handling of postmortem tissue.
Collapse
Affiliation(s)
- Ian C Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK.,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Susan C Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK.,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - J Ciaran Hutchinson
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK.,Department of Histopathology, Great Ormond Street Hospital for Children, London, UK
| | - Neil J Sebire
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK.,Department of Histopathology, Great Ormond Street Hospital for Children, London, UK
| | - Owen J Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK. .,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK. .,NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK.
| |
Collapse
|
15
|
Leyssens L, Pestiaux C, Kerckhofs G. A Review of Ex Vivo X-ray Microfocus Computed Tomography-Based Characterization of the Cardiovascular System. Int J Mol Sci 2021; 22:3263. [PMID: 33806852 PMCID: PMC8004599 DOI: 10.3390/ijms22063263] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/17/2021] [Accepted: 03/18/2021] [Indexed: 12/27/2022] Open
Abstract
Cardiovascular malformations and diseases are common but complex and often not yet fully understood. To better understand the effects of structural and microstructural changes of the heart and the vasculature on their proper functioning, a detailed characterization of the microstructure is crucial. In vivo imaging approaches are noninvasive and allow visualizing the heart and the vasculature in 3D. However, their spatial image resolution is often too limited for microstructural analyses, and hence, ex vivo imaging is preferred for this purpose. Ex vivo X-ray microfocus computed tomography (microCT) is a rapidly emerging high-resolution 3D structural imaging technique often used for the assessment of calcified tissues. Contrast-enhanced microCT (CE-CT) or phase-contrast microCT (PC-CT) improve this technique by additionally allowing the distinction of different low X-ray-absorbing soft tissues. In this review, we present the strengths of ex vivo microCT, CE-CT and PC-CT for quantitative 3D imaging of the structure and/or microstructure of the heart, the vasculature and their substructures in healthy and diseased state. We also discuss their current limitations, mainly with regard to the contrasting methods and the tissue preparation.
Collapse
Affiliation(s)
- Lisa Leyssens
- Institute of Mechanics, Materials, and Civil Engineering, Université Catholique de Louvain, 1348 Louvain-la-Neuve, Belgium; (L.L.); (C.P.)
- Institute of Experimental and Clinical Research, Université Catholique de Louvain, 1200 Woluwe-Saint-Lambert, Belgium
| | - Camille Pestiaux
- Institute of Mechanics, Materials, and Civil Engineering, Université Catholique de Louvain, 1348 Louvain-la-Neuve, Belgium; (L.L.); (C.P.)
- Institute of Experimental and Clinical Research, Université Catholique de Louvain, 1200 Woluwe-Saint-Lambert, Belgium
| | - Greet Kerckhofs
- Institute of Mechanics, Materials, and Civil Engineering, Université Catholique de Louvain, 1348 Louvain-la-Neuve, Belgium; (L.L.); (C.P.)
- Institute of Experimental and Clinical Research, Université Catholique de Louvain, 1200 Woluwe-Saint-Lambert, Belgium
- Department of Materials Engineering, Katholieke Universiteit Leuven, 3001 Leuven, Belgium
- Prometheus, Division of Skeletal Tissue Engineering, Katholieke Universiteit Leuven, 3000 Leuven, Belgium
| |
Collapse
|
16
|
Shelmerdine SC, Simcock IC, Hutchinson JC, Guy A, Ashworth MT, Sebire NJ, Arthurs OJ. Postmortem microfocus computed tomography for noninvasive autopsies: experience in >250 human fetuses. Am J Obstet Gynecol 2021; 224:103.e1-103.e15. [PMID: 32682860 PMCID: PMC7805479 DOI: 10.1016/j.ajog.2020.07.019] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 07/02/2020] [Accepted: 07/14/2020] [Indexed: 12/16/2022]
Abstract
Background Noninvasive imaging autopsy alternatives for fetuses weighing <500 grams are limited. Microfocus computed tomography has been reported as a viable option in small case series with the potential to avoid an invasive autopsy. Implementation of postmortem microfocus computed tomography in a large cohort as part of routine clinical service has yet been unreported, and realistic “autopsy prevention rates” are unknown. Objective This study aimed to describe the range of abnormalities detectable on fetal microfocus computed tomography in a clinical setting and additional findings identified on the antenatal ultrasound and to estimate the invasive autopsy avoidance rate (ie, cases in which imaging was sufficient to deem autopsy unnecessary). Study Design A prospective observational case series of all fetuses referred for microfocus computed tomography imaging at a single institution was conducted for 3 years (2016–2019). Imaging was reported by 2 pediatric radiologists before autopsy, with “decision to proceed” based on the specialist perinatal pathologists’ judgment and parental consent. Agreement rates between microfocus computed tomography and antenatal ultrasound were evaluated, and where feasible, diagnostic accuracy for microfocus computed tomography was calculated using autopsy as a reference standard. Results A total of 268 fetuses were included (2–350 grams body weight; 11–24 weeks’ gestation), with cause for demise in 122 of 268 (45.5%). Of the 122 fetuses, 64 (52.5%) exhibited fetal anomalies. Although 221 of 268 (82.5%) fetuses had consent for invasive autopsy, only 29 of the 221 (13.1%) underwent this procedure, which implied an autopsy avoidance rate of 192 of 221 (86.9%). Complete agreement was present for all brain, thoracic, and abdominal pathologies, whereas sensitivity and specificity for cardiac anomalies were 66.7% and 91.7%, respectively. Microfocus computed tomography and antenatal ultrasound agreement was found in 219 of 266 cases (81.9%), with partial agreement in 21 of 266 (7.9%) and disagreement in 26 of 266 (10.5%), mostly because of additional cardiac, soft tissue, or genitourinary findings by microfocus computed tomography, which were not seen on the ultrasound. Conclusion Fetal microfocus computed tomography imaging is a viable and useful tool for imaging early gestational fetuses and can avoid the need for invasive autopsy. Confirmation of antenatal diagnoses is achieved in most cases, and additional anomalies may also be detected.
Collapse
Affiliation(s)
- Susan C Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, United Kingdom; UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom; National Institute for Health Research Biomedical Research Centre, Great Ormond Street Hospital, London, United Kingdom.
| | - Ian C Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, United Kingdom; UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom; National Institute for Health Research Biomedical Research Centre, Great Ormond Street Hospital, London, United Kingdom
| | - John Ciaran Hutchinson
- Department of Paediatric Pathology, Great Ormond Street Hospital for Children, London, United Kingdom
| | - Anna Guy
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, United Kingdom
| | - Michael T Ashworth
- Department of Paediatric Pathology, Great Ormond Street Hospital for Children, London, United Kingdom
| | - Neil J Sebire
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom; Department of Paediatric Pathology, Great Ormond Street Hospital for Children, London, United Kingdom; National Institute for Health Research Biomedical Research Centre, Great Ormond Street Hospital, London, United Kingdom
| | - Owen J Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, United Kingdom; UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom; National Institute for Health Research Biomedical Research Centre, Great Ormond Street Hospital, London, United Kingdom
| |
Collapse
|
17
|
Frauenfelder C, Shelmerdine SC, Simcock IC, Hall A, Hutchinson JC, Ashworth MT, Arthurs OJ, Butler CR. Micro-CT Imaging of Pediatric Thyroglossal Duct Cysts: A Prospective Case Series. Front Pediatr 2021; 9:746010. [PMID: 34557462 PMCID: PMC8453197 DOI: 10.3389/fped.2021.746010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 08/16/2021] [Indexed: 12/18/2022] Open
Abstract
Objectives: To determine the feasibility of micro-CT as a high-resolution 3D imaging tool for thyroglossal duct cysts and to evaluate its role augmenting traditional histopathological examination of resected specimens. Methods: A single centre, prospective case series of consecutive children undergoing excision of a thyroglossal duct cyst was performed at a quaternary paediatric referral hospital in the United Kingdom. Consecutive children listed for excision of a thyroglossal duct cyst whose parents agreed to participate were included and there were no exclusion criteria. Results: Surgically excised thyroglossal duct cyst or remnant specimens from five patients (two males, three females) were examined using micro-CT alongside traditional histopathological examination. In all cases, micro-CT imaging was able to demonstrate 3D imaging datasets of the specimens successfully and direct radio-pathological comparisons were made (Figures 1-5, Supplementary Video 1). Conclusions: The study has shown the feasibility and utility of post-operative micro-CT imaging of thyroglossal duct cysts specimens as a visual aid to traditional histopathological examination. It better informs the pathological specimen sectioning using multi-planar reconstruction and volume rendering tools without tissue destruction. In the complex, often arborised relationship between a thyroglossal duct cyst and the hyoid, micro-CT provides valuable image plane orientation and indicates proximity of the duct to the surgical margins. This is the first case series to explore the use of micro-CT imaging for pediatric thyroglossal duct specimens and it informs future work investigating the generalizability of micro-CT imaging methods for other lesions, particularly those from the head and neck region where precisely defining margins of excision may be challenging.
Collapse
Affiliation(s)
- Claire Frauenfelder
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom.,Discipline of Surgery, School of Medicine, University of Adelaide, Adelaide, SA, Australia
| | - Susan C Shelmerdine
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom.,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, United Kingdom
| | - Ian C Simcock
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom.,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, United Kingdom
| | - Andrew Hall
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom
| | - John Ciaran Hutchinson
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom.,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, United Kingdom.,Department of Histopathology, St Thomas' Hospital, London, United Kingdom
| | - Michael T Ashworth
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom
| | - Owen J Arthurs
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom.,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, United Kingdom
| | - Colin R Butler
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, United Kingdom.,UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, United Kingdom
| |
Collapse
|
18
|
Novo Matos J, Garcia-Canadilla P, Simcock IC, Hutchinson JC, Dobromylskyj M, Guy A, Arthurs OJ, Cook AC, Luis Fuentes V. Micro-computed tomography (micro-CT) for the assessment of myocardial disarray, fibrosis and ventricular mass in a feline model of hypertrophic cardiomyopathy. Sci Rep 2020; 10:20169. [PMID: 33214588 PMCID: PMC7678873 DOI: 10.1038/s41598-020-76809-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 11/02/2020] [Indexed: 01/15/2023] Open
Abstract
Micro-computed tomography (micro-CT) is a high-resolution imaging modality that provides accurate tissue characterization. Hypertrophic cardiomyopathy (HCM) occurs as a spontaneous disease in cats, and is characterized by myocardial hypertrophy, disarray and fibrosis, as in humans. While hypertrophy/mass (LVM) can be objectively measured, fibrosis and myocyte disarray are difficult to assess. We evaluated the accuracy of micro-CT for detection and quantification of myocardial disarray and fibrosis by direct comparison with histopathology. 29 cat hearts (12 normal and 17 HCM hearts) underwent micro-CT and pathologic examination. Myocyte orientation was assessed using structure tensor analysis by determination of helical angle (HA), fractional anisotropy (FA) and myocardial disarray index (MDI). Fibrosis was segmented and quantified based on comparison of gray-scale values in normal and fibrotic myocardium. LVM was obtained by determining myocardial volume. Myocardial segments with low FA, low MDI and disruption of normal HA transmural profile on micro-CT were associated with myocardial disarray on histopathology. FA was consistently lower in HCM than normal hearts. Assessment of fibrosis on micro-CT closely matched the histopathologic evaluation. LVM determined by micro-CT was higher in HCM than normal hearts. Micro-CT can be used to detect and quantify myocardial disarray and fibrosis and determine myocardial mass in HCM.
Collapse
Affiliation(s)
- Jose Novo Matos
- Clinical Sciences and Services, Royal Veterinary College, London, UK.
| | - Patricia Garcia-Canadilla
- Institut D'Investigacions Biomèdiques August Pi I Sunyer, Barcelona, Spain.,Institute of Cardiovascular Science, University College London, London, UK
| | - Ian C Simcock
- Department of Radiology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - J Ciaran Hutchinson
- Department of Histopathology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK
| | | | - Anna Guy
- Department of Radiology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK
| | - Owen J Arthurs
- Department of Radiology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Andrew C Cook
- Institute of Cardiovascular Science, University College London, London, UK
| | | |
Collapse
|
19
|
Novo Matos J, Garcia-Canadilla P, Simcock IC, Hutchinson JC, Dobromylskyj M, Guy A, Arthurs OJ, Cook AC, Luis Fuentes V. Micro-computed tomography (micro-CT) for the assessment of myocardial disarray, fibrosis and ventricular mass in a feline model of hypertrophic cardiomyopathy. Sci Rep 2020. [PMID: 33214588 DOI: 10.1038/s41598-020-76809-5.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Micro-computed tomography (micro-CT) is a high-resolution imaging modality that provides accurate tissue characterization. Hypertrophic cardiomyopathy (HCM) occurs as a spontaneous disease in cats, and is characterized by myocardial hypertrophy, disarray and fibrosis, as in humans. While hypertrophy/mass (LVM) can be objectively measured, fibrosis and myocyte disarray are difficult to assess. We evaluated the accuracy of micro-CT for detection and quantification of myocardial disarray and fibrosis by direct comparison with histopathology. 29 cat hearts (12 normal and 17 HCM hearts) underwent micro-CT and pathologic examination. Myocyte orientation was assessed using structure tensor analysis by determination of helical angle (HA), fractional anisotropy (FA) and myocardial disarray index (MDI). Fibrosis was segmented and quantified based on comparison of gray-scale values in normal and fibrotic myocardium. LVM was obtained by determining myocardial volume. Myocardial segments with low FA, low MDI and disruption of normal HA transmural profile on micro-CT were associated with myocardial disarray on histopathology. FA was consistently lower in HCM than normal hearts. Assessment of fibrosis on micro-CT closely matched the histopathologic evaluation. LVM determined by micro-CT was higher in HCM than normal hearts. Micro-CT can be used to detect and quantify myocardial disarray and fibrosis and determine myocardial mass in HCM.
Collapse
Affiliation(s)
- Jose Novo Matos
- Clinical Sciences and Services, Royal Veterinary College, London, UK.
| | - Patricia Garcia-Canadilla
- Institut D'Investigacions Biomèdiques August Pi I Sunyer, Barcelona, Spain.,Institute of Cardiovascular Science, University College London, London, UK
| | - Ian C Simcock
- Department of Radiology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - J Ciaran Hutchinson
- Department of Histopathology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK
| | | | - Anna Guy
- Department of Radiology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK
| | - Owen J Arthurs
- Department of Radiology, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, UK.,National Institute for Health Research Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Andrew C Cook
- Institute of Cardiovascular Science, University College London, London, UK
| | | |
Collapse
|
20
|
Kang X, Carlin A, Cannie MM, Sanchez TC, Jani JC. Fetal postmortem imaging: an overview of current techniques and future perspectives. Am J Obstet Gynecol 2020; 223:493-515. [PMID: 32376319 DOI: 10.1016/j.ajog.2020.04.034] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 04/19/2020] [Accepted: 04/28/2020] [Indexed: 12/19/2022]
Abstract
Fetal death because of miscarriage, unexpected intrauterine fetal demise, or termination of pregnancy is a traumatic event for any family. Despite advances in prenatal imaging and genetic diagnosis, conventional autopsy remains the gold standard because it can provide additional information not available during fetal life in up to 40% of cases and this by itself may change the recurrence risk and hence future counseling for parents. However, conventional autopsy is negatively affected by procedures involving long reporting times because the fetal brain is prone to the effect of autolysis, which may result in suboptimal examinations, particularly of the central nervous system. More importantly, fewer than 50%-60% of parents consent to invasive autopsy, mainly owing to the concerns about body disfigurement. Consequently, this has led to the development of noninvasive perinatal virtual autopsy using imaging techniques. Because a significant component of conventional autopsy involves the anatomic examination of organs, imaging techniques such as magnetic resonance imaging, ultrasound, and computed tomography are possible alternatives. With a parental acceptance rate of nearly 100%, imaging techniques as part of postmortem examination have become widely used in recent years in some countries. Postmortem magnetic resonance imaging using 1.5-Tesla magnets is the most studied technique and offers an overall diagnostic accuracy of 77%-94%. It is probably the best choice as a virtual autopsy technique for fetuses >20 weeks' gestation. However, for fetuses <20 weeks' gestation, its performance is poor. The use of higher magnetic resonance imaging magnetic fields such as 3-Tesla may slightly improve performance. Of note, in cases of fetal maceration, magnetic resonance imaging may offer diagnoses in a proportion of brain lesions wherein conventional autopsy fails. Postmortem ultrasound examination using a high-frequency probe offers overall sensitivity and specificity of 67%-77% and 74%-90%, respectively, with the advantage of easy access and affordability. The main difference between postmortem ultrasound and magnetic resonance imaging relates to their respective abilities to obtain images of sufficient quality for a confident diagnosis. The nondiagnostic rate using postmortem ultrasound ranges from 17% to 30%, depending on the organ examined, whereas the nondiagnostic rate using postmortem magnetic resonance imaging in most situations is far less than 10%. For fetuses ≤20 weeks' gestation, microfocus computed tomography achieves close to 100% agreement with autopsy and is likely to be the technique of the future in this subgroup. The lack of histology has always been listed as 1 limitation of all postmortem imaging techniques. Image-guided needle tissue biopsy coupled with any postmortem imaging can overcome this limitation. In addition to describing the diagnostic accuracy and limitations of each imaging technology, we propose a novel, stepwise diagnostic approach and describe the possible application of these techniques in clinical practice as an alternative or an adjunct or for triage to select cases that would specifically benefit from invasive examination, with the aim of reducing parental distress and pathologist workload. The widespread use of postmortem fetal imaging is inevitable, meaning that hurdles such as specialized training and dedicated financing must be overcome to improve access to these newer, well-validated techniques.
Collapse
Affiliation(s)
- Xin Kang
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Andrew Carlin
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Mieke M Cannie
- Radiology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium; Department of Radiology, UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Teresa Cos Sanchez
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Jacques C Jani
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium.
| |
Collapse
|
21
|
Simcock IC, Hutchinson JC, Shelmerdine SC, Matos JN, Sebire NJ, Fuentes VL, Arthurs OJ. Investigation of optimal sample preparation conditions with potassium triiodide and optimal imaging settings for microfocus computed tomography of excised cat hearts. Am J Vet Res 2020; 81:326-333. [PMID: 32228254 DOI: 10.2460/ajvr.81.4.326] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To determine optimal sample preparation conditions with potassium triiodide (I2KI) and optimal imaging settings for microfocus CT (micro-CT) of excised cat hearts. SAMPLE 7 excised hearts (weight range, 10 to 17.6 g) obtained from healthy adult cats after euthanasia by IV injection of pentobarbital sodium. PROCEDURES Following excision, the hearts were preserved in 10% formaldehyde solution. Six hearts were immersed in 1.25% I2KI solution (n = 3) or 2.5% I2KI solution (3) for a 12-day period. Micro-CT images were acquired at time 0 (prior to iodination) then approximately every 24 and 48 hours thereafter to determine optimal sample preparation conditions (ie, immersion time and concentration of I2KI solution). Identified optimal conditions were then used to prepare the seventh heart for imaging; changes in voltage, current, exposure time, and gain on image quality were evaluated to determine optimal settings (ie, maximal signal-to-noise and contrast-to-noise ratios). Images were obtained at a voxel resolution of 30 μm. A detailed morphological assessment of the main cardiac structures of the seventh heart was then performed. RESULTS Immersion in 2.5% I2KI solution for 48 hours was optimal for sample preparation. The optimal imaging conditions included a tube voltage of 100 kV, current of 150 μA, and exposure time of 354 milliseconds; scan duration was 12 minutes. CONCLUSIONS AND CLINICAL RELEVANCE Results provided an optimal micro-CT imaging protocol for excised cat hearts prepared with I2KI solution that could serve as a basis for future studies of micro-CT for high resolution 3-D imaging of cat hearts.
Collapse
|
22
|
Castro PT, Aranda OL, Marchiori E, Araújo LFBD, Alves HDL, Lopes RT, Werner H, Araujo Júnior E. Proportional vascularization along the fallopian tubes and ovarian fimbria: assessment by confocal microtomography. Radiol Bras 2020; 53:161-166. [PMID: 32587423 PMCID: PMC7302899 DOI: 10.1590/0100-3984.2019.0080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Objective To evaluate and reconstruct three-dimensional images of vascularization along the fallopian tube (FT), as well as to determine its relationship with the ovary and ovarian fimbria, and to quantify the blood vessels along the FT according to its anatomical segments, using confocal microtomography (micro-CT). Materials and Methods Nine specimens (six FTs and three FTs with ovaries) were fixed in a solution of 10% formalin for > 24 h at room temperature. Iodine staining was performed by soaking the specimens in 10% Lugol’s solution for 24 h. All specimens were evaluated using micro-CT. A morphometric analysis was performed on the reconstructed images to quantify the vascular distribution along the FT. Results In the FTs evaluated, the density of blood vessels was significantly greater in the fimbrial segments than in the isthmic segments (p < 0.05). The ovarian fimbria was clearly identified, demonstrating the important relationship between these vessels and the FT fimbriae. Conclusion We believe that the vascularization in the fimbriae is greater than and disproportional that in the other segments of FT, and that the ovarian fimbria plays an important role in the development of that difference.
Collapse
Affiliation(s)
- Pedro Teixeira Castro
- Universidade Federal do Rio de Janeiro (UFRJ), Brazil; Clínica Diagnóstico por Imagem (CDPI), Brazil
| | - Osvaldo Luiz Aranda
- Universidade Federal do Rio de Janeiro (UFRJ), Brazil; Universidade de Vassouras, Brazil
| | | | | | - Haimon Diniz Lopes Alves
- Universidade Federal do Rio de Janeiro (UFRJ), Brazil; Universidade do Estado do Rio de Janeiro (UERJ), Brazil
| | | | | | | |
Collapse
|
23
|
Wang Y, Zhang J, Feng W, Cao H, He Q, Xu J, Zeng H, Xie M. Description of misdiagnosis and missed diagnosis of fetal complex heart malformations by prenatal echocardiography combined with postnatal cardiovascular casting. Prenat Diagn 2020; 40:792-802. [PMID: 32239683 DOI: 10.1002/pd.5689] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 11/22/2019] [Accepted: 03/21/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To compare prenatal echocardiography with postnatal cardiovascular casting for detection of fetal cardiovascular malformations, and to discuss the causes of prenatal misdiagnosis and missed diagnosis. METHODS We retrospectively identified patients from 2013 to 2018 at our Maternal-Fetal Medicine Center who were reported to have a fetal diagnosis of severe congenital heart malformations (CHMs). Subjects had postnatal confirmation of CHMs. Prenatal and postnatal medical records, including ultrasound results and casting findings, were reviewed and analyzed. RESULTS Postnatal casting showed that all 35 fetuses had complex CHMs. In these 35 cases, 90 cardiovascular malformations were found by postnatal casting, and 69 were detected by prenatal echocardiography. Among the other 21 cardiovascular malformations, 7 were misdiagnosed and 14 diagnoses were missed by prenatal ultrasound. CONCLUSION Prenatal echocardiography may lead to misdiagnosis and missed diagnoses, especially in cases with great arterial branching anomalies. Postnatal casting can demonstrate the configuration of the great vessels and smaller branches directly. Thus, understanding of such malformations via postnatal casting may help to improve prenatal diagnostic accuracy.
Collapse
Affiliation(s)
- Yu Wang
- Department of Ultrasound, Xiangyang No. 1 People's Hospital, Hubei University of Medicine, Xiangyang, China
| | - Jiaqi Zhang
- Department of Ultrasound, Xiangyang No. 1 People's Hospital, Hubei University of Medicine, Xiangyang, China
| | - Wei Feng
- Department of Ultrasound, Xiangyang No. 1 People's Hospital, Hubei University of Medicine, Xiangyang, China
| | - Haiyan Cao
- Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Qiaoyue He
- Department of Ultrasound, Xiangyang No. 1 People's Hospital, Hubei University of Medicine, Xiangyang, China
| | - Jinzhi Xu
- Department of Ultrasound, Xiangyang No. 1 People's Hospital, Hubei University of Medicine, Xiangyang, China
| | - He Zeng
- Department of Ultrasound, Xiangyang No. 1 People's Hospital, Hubei University of Medicine, Xiangyang, China
| | - Mingxing Xie
- Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
24
|
Novel imaging techniques to study postmortem human fetal anatomy: a systematic review on microfocus-CT and ultra-high-field MRI. Eur Radiol 2019; 30:2280-2292. [PMID: 31834508 PMCID: PMC7062658 DOI: 10.1007/s00330-019-06543-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 10/10/2019] [Accepted: 10/23/2019] [Indexed: 01/07/2023]
Abstract
Background MRI and CT have been extensively used to study fetal anatomy for research and diagnostic purposes, enabling minimally invasive autopsy and giving insight in human fetal development. Novel (contrast-enhanced) microfocus CT (micro-CT) and ultra-high-field (≥ 7.0 T) MRI (UHF-MRI) techniques now enable micron-level resolution that combats the disadvantages of low-field MRI and conventional CT. Thereby, they might be suitable to study fetal anatomy in high detail and, in time, contribute to the postmortem diagnosis of fetal conditions. Objectives (1) To systematically examine the usability of micro-CT and UHF-MRI to study postmortem human fetal anatomy, and (2) to analyze factors that govern success at each step of the specimen preparation and imaging. Method MEDLINE and EMBASE were systematically searched to identify publications on fetal imaging by micro-CT or UHF-MRI. Scanning protocols were summarized and best practices concerning specimen preparation and imaging were enumerated. Results Thirty-two publications reporting on micro-CT and UHF-MRI were included. The majority of the publications focused on imaging organs separately and seven publications focused on whole body imaging, demonstrating the possibility of visualization of small anatomical structures with a resolution well below 100 μm. When imaging soft tissues by micro-CT, the fetus should be stained by immersion in Lugol’s staining solution. Conclusion Micro-CT and UHF-MRI are both excellent imaging techniques to provide detailed images of gross anatomy of human fetuses. The present study offers an overview of the current best practices when using micro-CT and/or UHF-MRI to study fetal anatomy for clinical and research purposes. Key Points • Micro-CT and UHF-MRI can both be used to study postmortem human fetal anatomy for clinical and research purposes. • Micro-CT enables high-resolution imaging of fetal specimens in relatively short scanning time. However, tissue staining using a contrast solution is necessary to enable soft-tissue visualization. • UHF-MRI enables high-resolution imaging of fetal specimens, without the necessity of prior staining, but with the drawback of long scanning time. Electronic supplementary material The online version of this article (10.1007/s00330-019-06543-8) contains supplementary material, which is available to authorized users.
Collapse
|
25
|
Shelmerdine SC, Hutchinson JC, Arthurs OJ, Sebire NJ. Latest developments in post-mortem foetal imaging. Prenat Diagn 2019; 40:28-37. [PMID: 31525275 DOI: 10.1002/pd.5562] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 08/29/2019] [Accepted: 09/07/2019] [Indexed: 12/11/2022]
Abstract
A sustained decline in parental consent rates for perinatal autopsies has driven the development of less-invasive methods for death investigation. A wide variety of imaging modalities have been developed for this purpose and include post-mortem whole body magnetic resonance imaging (MRI), ultrasound, computed tomography (CT) and micro-focus CT techniques. These are also vital for "minimally invasive" methods, which include potential for tissue sampling, such as image guidance for targeted biopsies and laparoscopic-assisted techniques. In this article, we address the range of imaging techniques currently in clinical practice and those under development. Significant advances in high-field MRI and micro-focus CT imaging show particular promise for smaller and earlier gestation foetuses. We also review how MRI biomarkers such as diffusion-weighted imaging and organ volumetric analysis may aid diagnosis and image interpretation in the absence of autopsy data. Three-dimensional printing and augmented reality may help make imaging findings more accessible to parents, colleagues and trainees.
Collapse
Affiliation(s)
- Susan C Shelmerdine
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| | - John C Hutchinson
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| | - Owen J Arthurs
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| | - Neil J Sebire
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| |
Collapse
|
26
|
Michaud K, Genet P, Sabatasso S, Grabherr S. Postmortem imaging as a complementary tool for the investigation of cardiac death. Forensic Sci Res 2019; 4:211-222. [PMID: 31489387 PMCID: PMC6713140 DOI: 10.1080/20961790.2019.1630944] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 06/06/2019] [Accepted: 06/10/2019] [Indexed: 12/26/2022] Open
Abstract
In the past 2 decades, modern radiological methods, such as multiple detector computed tomography (MDCT), MDCT-angiography, and cardiac magnetic resonance imaging (MRI) were introduced into postmortem practice for investigation of sudden death (SD), including cases of sudden cardiac death (SCD). In forensic cases, the underlying cause of SD is most frequently cardiovascular with coronary atherosclerotic disease as the leading cause. There are many controversies about the role of postmortem imaging in establishing the cause of death and especially the value of minimally invasive autopsy techniques. This paper discusses the state of the art for postmortem radiological evaluation of the heart compared to classical postmortem examination, especially in cases of SCD. In SCD cases, postmortem CT is helpful to estimate the heart size and to visualize haemopericardium and calcified plaques and valves, as well as to identify and locate cardiovascular devices. Angiographic methods are useful to provide a detailed view of the coronary arteries and to analyse them, especially regarding the extent and location of stenosis and obstruction. In postsurgical cases, it allows verification and documentation of the patency of stents and bypass grafts before opening the body. Postmortem MRI is used to investigate soft tissues such as the myocardium, but images are susceptible to postmortem changes and further work is necessary to increase the understanding of these radiological aspects, especially of the ischemic myocardium. In postsurgery cases, the value of postmortem imaging of the heart is reportedly for the diagnostic and documentation purposes. The implementation of new imaging methods into routine postmortem practice is challenging, as it requires not only an investment in equipment but, more importantly, investment in the expertise of interpreting the images. Once those requirements are implemented, however, they bring great advantages in investigating cases of SCD, as they allow documentation of the body, orientation of sampling for further analyses and gathering of other information that cannot be obtained by conventional autopsy such as a complete visualization of the vascular system using postmortem angiography.Key pointsThere are no established guidelines for the interpretation of postmortem imaging examination of the heartAt present, postmortem imaging methods are considered as less accurate than the autopsy for cardiac deathsPostmortem imaging is useful as a complementary tool for cardiac deathsThere is still a need to validate postmortem imaging in cardiac deaths by comparing with autopsy findings.
Collapse
Affiliation(s)
- Katarzyna Michaud
- Lausanne University Hospital and University of Lausanne, University Center of Legal Medicine Lausanne-Geneva, Lausanne, Switzerland
| | - Pia Genet
- Lausanne University Hospital and University of Lausanne, University Center of Legal Medicine Lausanne-Geneva, Lausanne, Switzerland
- Geneva University Hospital, University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland
| | - Sara Sabatasso
- Geneva University Hospital, University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland
| | - Silke Grabherr
- Lausanne University Hospital and University of Lausanne, University Center of Legal Medicine Lausanne-Geneva, Lausanne, Switzerland
- Geneva University Hospital, University Center of Legal Medicine Lausanne-Geneva, Geneva, Switzerland
| |
Collapse
|
27
|
Lombardi S, Scola E, Ippolito D, Zambelli V, Botta G, Cuttin S, Triulzi F, Lombardi CM. Micro-computed tomography: a new diagnostic tool in postmortem assessment of brain anatomy in small fetuses. Neuroradiology 2019; 61:737-746. [PMID: 30693410 DOI: 10.1007/s00234-019-02168-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 01/11/2019] [Indexed: 02/07/2023]
Abstract
PURPOSE The aim of our study was to evaluate the postmortem micro-CT anatomy of early fetal human fetal brains, either in situ or isolated. METHODS We studied 12 ex vivo specimens, 9 whole human fetuses (9-18 GW), and 3 isolated samples (16-26 GW). Specimens were fixed in formalin, then immersed in Lugol solution. Images were evaluated by two neuroradiologists. The depiction of CNS structures was defined based on the comparison between micro-CT images and a reference histologic anatomical Atlas of human brain development. RESULTS Micro-CT provided informative high-resolution brain images in all cases, with the exception of one case (9 weeks) due to advanced maceration. All major CNS structures (i.e., brain hemispheres, layering, ventricles, germinal neuroepithelium, basal ganglia, corpus callosum, major cranial nerves, and structures of the head and neck) were recognizable. CONCLUSIONS Micro-CT imaging of the early fetal brain is feasible and provides high-quality images that correlate with the histological Atlas of the human brain, offering multiplanar and volumetric images that can be stored and shared for clinical, teaching, and research purposes.
Collapse
Affiliation(s)
- Sophie Lombardi
- Department of Neuroradiology, Grande Ospedale Metropolitano Niguarda, Milan, Italy.
| | - Elisa Scola
- Neuroradiology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | | | - Vanessa Zambelli
- Department of Health Sciences, Università di Milano-Bicocca, Milan, Italy
| | - Giovanni Botta
- Azienda Ospedaliera Città della Salute e delle Scienze di Torino, Presidio Ospedaliero OIRM-Sant'Anna, Turin, Italy
| | - Serena Cuttin
- Department of Pathology, San Gerardo Hospital, Monza, Italy
| | - Fabio Triulzi
- Neuroradiology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
- Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Milan, Italy
| | | |
Collapse
|
28
|
Shelmerdine SC, Singh M, Norman W, Jones R, Sebire NJ, Arthurs OJ. Automated data extraction and report analysis in computer-aided radiology audit: practice implications from post-mortem paediatric imaging. Clin Radiol 2019; 74:733.e11-733.e18. [PMID: 31160039 DOI: 10.1016/j.crad.2019.04.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 04/24/2019] [Indexed: 10/26/2022]
Abstract
AIM To determine local departmental adherence to the paediatric post-mortem magnetic resonance imaging (MRI) protocols, using a customised automated computational approach. MATERIALS AND METHODS A retrospective review of 460 whole-body post-mortem MRI examinations performed at Great Ormond Street Hospital for Children over a 5.5-year period was assessed for adherence to a full or abbreviated imaging sequence protocol. A simple computer program was developed to batch process DICOM (digital imaging and communications in medicine) files, extracting imaging sequence details, followed by natural language processing (NLP) of authorised reports to automate information extraction of diagnostic image quality. RESULTS The program was able to extract study parameters from the entire dataset (approximately 80 GB of data) in a few hours, and retrieve information on diagnostic image quality using NLP with an overall diagnostic accuracy for data extraction of 96.7% (445/460, 95% confidence interval [CI]: 94.7-98%). The full imaging protocol was adhered to in 305/460 (66.3%) cases, and an abbreviated protocol in 140/460 (30.4%) cases. Overall, 423/460 (91.9%) of studies were of diagnostic quality. These included 298/305 (97.7%) of the full protocol, 111/140 (79.3%) of the abbreviated protocol. In only five cases were the examinations non-diagnostic for all body systems, all of whom weighed <100 g (24.7-72 g) and imaged using the abbreviated protocol. CONCLUSION The present study demonstrated a successful application of an automated approach for data collection for audit and quality assessment purposes using paediatric post-mortem imaging as a specific example. Re-audit of these data following change implementation will be straightforward now that the automated workflow is clearly established.
Collapse
Affiliation(s)
- S C Shelmerdine
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK; UCL Great Ormond Street Institute of Child Health, London, UK.
| | - M Singh
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - W Norman
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - R Jones
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - N J Sebire
- UCL Great Ormond Street Institute of Child Health, London, UK; Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - O J Arthurs
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK; UCL Great Ormond Street Institute of Child Health, London, UK
| |
Collapse
|
29
|
Staicu A, Albu C, Popa-Stanila R, Chiriac L, Boitor-Borza D, Bondor C, Kovacs T, Caracostea G, Rotar IC, Turcu RVF, Simon S, Muresan D, Stamatian F. Potential clinical benefits and limitations of fetal virtopsy using high-field MRI at 7 Tesla versus stereomicroscopic autopsy to assess first trimester fetuses. Prenat Diagn 2019; 39:505-518. [PMID: 30980413 DOI: 10.1002/pd.5457] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Revised: 03/21/2019] [Accepted: 03/23/2019] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The aim of this study was to establish the diagnostic accuracy of high-field magnetic resonance imaging (MRI) at 7 Tesla (T) compared with that of stereomicroscopic autopsy for assessing first trimester fetuses. METHODS Nine consecutive cases of first trimester fetuses resulting from spontaneous and therapeutic pregnancy termination were considered. The cases were divided into two groups according to gestational age: the Embryo Group with cases of nine to 10 gestational weeks (GWs) and the Fetus Group with cases of 13 GWs. The first group was scanned using three-dimensional fast imaging with steady state precession (3D FISP), and the second group was scanned using a two-dimensional (2D) turbo spin-echo high-resolution T2-weighted imaging (T2 WI) protocol. A radiologist and two embryologists interpreted the images. All cases were evaluated by invasive autopsy, with pathologist blinded to the imaging results. In total, the database included 270 items for evaluation (9 cases × 30 structures/case). RESULTS The global agreement between fetal high-field virtopsy and microscopic or stereomicroscopic autopsy was evaluated using 225 evaluation items visible by both methods. Overall, using microscopic examination and stereomicroscopic autopsy as the gold standard, fetal high-field virtopsy had a sensitivity of 94.6% [95% CI, 87.2-98.3] and a specificity of 97.6% [95% CI, 95-98.8]. The positive predictive value (PPV) was 93% [95% CI, 85.7-96.6], and the negative predictive value (NPV) was 98.2% [95% CI, 95.7-99.4]. Cohen kappa coefficient of agreement was k = 0.92 [95% CI, 0.82-0.97], and the McNemar test showed p = 1.00. CONCLUSIONS Virtual autopsy using high-field MRI at 7 T can be considered a safe alternative approach to stereomicroscopic autopsy for the assessment of fetal structural anomalies at the end of the first trimester of pregnancy.
Collapse
Affiliation(s)
- Adelina Staicu
- 1st Department of Obstetrics and Gynaecology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Camelia Albu
- Department of Pathology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania.,Centre of Advanced Research Studies, Emergency County Hospital, IMOGEN, Cluj-Napoca, Romania
| | - Roxana Popa-Stanila
- Centre of Advanced Research Studies, Emergency County Hospital, IMOGEN, Cluj-Napoca, Romania.,Department of Radiology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Liviu Chiriac
- Department of Medical Biophysics, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania.,National Magnetic Resonance Centre, Babeș Bolyai University, Cluj-Napoca, Romania
| | - Dan Boitor-Borza
- Department of Human Anatomy and Embryology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Cosmina Bondor
- Department of Medical Informatics and Biostatistics, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Tunde Kovacs
- 1st Department of Obstetrics and Gynaecology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania.,Centre of Advanced Research Studies, Emergency County Hospital, IMOGEN, Cluj-Napoca, Romania
| | - Gabriela Caracostea
- 1st Department of Obstetrics and Gynaecology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Ioana Cristina Rotar
- 1st Department of Obstetrics and Gynaecology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - R V Flaviu Turcu
- National Magnetic Resonance Centre, Babeș Bolyai University, Cluj-Napoca, Romania.,Faculty of Physic, Babeș Bolyai University, Cluj-Napoca, Romania
| | - Simion Simon
- National Magnetic Resonance Centre, Babeș Bolyai University, Cluj-Napoca, Romania.,Faculty of Physic, Babeș Bolyai University, Cluj-Napoca, Romania
| | - Daniel Muresan
- 1st Department of Obstetrics and Gynaecology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Florin Stamatian
- Centre of Advanced Research Studies, Emergency County Hospital, IMOGEN, Cluj-Napoca, Romania
| |
Collapse
|
30
|
Shelmerdine SC, Arthurs OJ, Gilpin I, Norman W, Jones R, Taylor AM, Sebire NJ, Chitty LS. Is traditional perinatal autopsy needed after detailed fetal ultrasound and post-mortem MRI? Prenat Diagn 2019; 39:818-829. [PMID: 30892705 DOI: 10.1002/pd.5448] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 02/27/2019] [Accepted: 03/14/2019] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To determine the additional yield from autopsy following prenatal ultrasound and post-mortem magnetic resonance imaging (PMMR) for structural abnormalities. METHOD PMMR was performed on consecutive fetuses over a 6-year period. Prenatal ultrasound and PMMR findings were categorised as concordant, partially concordant or discordant findings. The yield of new and clinically significant information from autopsy was assessed. Diagnostic accuracies for both modalities were calculated, using autopsy as reference standard. RESULTS Our study consisted of 81 fetuses. PMMR and prenatal ultrasound findings were concordant in 44/81 (54.3%), partially concordant in 26/81 (32.1%) and discordant in 11/81 (13.6%) cases. In 19/81 cases (23%), autopsy provided additional information, which appeared clinically significant in 12 cases. In 10 of those 12 cases, there was discordance between PMMR and ultrasound. In only 2 of 44 cases where ultrasound and PMMR were concordant, did autopsy provide clinically significant information. Diagnostic accuracy rates for ultrasound were sensitivity of 76.8% (66.6%, 84.6%), specificity of 92.5% (88.9%, 95.0%). For PMMR the sensitivity was 79.0% (68.9%, 86.5%), specificity 97.9% (95.5%, 99.0%). PMMR had a significantly higher concordance rate with autopsy than ultrasound (89.0 vs 93.8%; P < .001). CONCLUSION Where PMMR and ultrasound are concordant, there is little additional yield from autopsy.
Collapse
Affiliation(s)
- Susan C Shelmerdine
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,UCL Great Ormond Street Institute of Child Health, London, UK
| | - Owen J Arthurs
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,UCL Great Ormond Street Institute of Child Health, London, UK
| | - Isobel Gilpin
- Perinatal Neurology and Neonatology, Imperial College London, London, UK
| | - Wendy Norman
- Cardiorespiratory Division, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, London, UK
| | - Rod Jones
- Cardiorespiratory Division, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, London, UK
| | - Andrew M Taylor
- Cardiorespiratory Division, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, London, UK
| | - Neil J Sebire
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,UCL Great Ormond Street Institute of Child Health, London, UK
| | - Lyn S Chitty
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,Genetics and Genomic Medicine, UCL Great Ormond Street Institute of Child Health, London, UK
| |
Collapse
|
31
|
Kang X, Shelmerdine SC, Hurtado I, Bevilacqua E, Hutchinson C, Mandalia U, Segers V, Cos Sanchez T, Cannie MM, Carlin A, Sebire NJ, Arthurs OJ, Jani JC. Postmortem examination of human fetuses: comparison of two-dimensional ultrasound with invasive autopsy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2019; 53:229-238. [PMID: 28782198 DOI: 10.1002/uog.18828] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2017] [Revised: 06/09/2017] [Accepted: 07/25/2017] [Indexed: 06/07/2023]
Abstract
OBJECTIVE To assess the diagnostic accuracy of postmortem ultrasound performed by operators blinded to prenatal findings and to invasive autopsy results in fetuses at different gestational ages and to investigate the effect of various parameters on its diagnostic success. METHODS We performed postmortem two-dimensional ultrasound examination, blinded to clinical details, on 163 fetuses at 13-42 weeks' gestation. Logistic regression analysis was used to investigate the effect of: (i) gestational age at postmortem ultrasound, (ii) presence of maceration and (iii) mode of death, on whether the exam succeeded or failed to reach a diagnosis. In 123 cases in which invasive autopsy was available, the diagnostic accuracy of ultrasound in detecting major organ abnormalities was evaluated, using invasive autopsy as the gold standard. RESULTS For the fetal brain, postmortem ultrasound exam was non-diagnostic in significantly more fetuses with maceration (39.5%; 17/43) vs those without maceration (20.0%; 24/120) (P = 0.013). For the fetal thorax, the exam was non-diagnostic in 34.1% (15/44) of fetuses < 20 weeks of gestation and in 10.9% (13/119) of fetuses ≥ 20 weeks (P < 0.001). For the heart and abdominal organs, there was no association between non-diagnostic postmortem ultrasound and the variables tested. For fetuses < 20 weeks, specificity of postmortem ultrasound examination was 83.3% for detection of anomalies of the brain, 68.6% for the thorax and 77.4% for the heart. For fetuses ≥ 20 weeks, sensitivity and specificity were, respectively, 61.9% and 74.2% for detection of anomalies of the brain, 29.5% and 87.0% for the thorax and 65.0% and 83.1% for the heart. For the fetal abdominal organs, sensitivity was 60.7% and specificity 75.8%, and postmortem ultrasound was particularly useful for detection of abnormalities of the kidneys, irrespective of gestational age. CONCLUSION Although maceration may lead to failure of postmortem ultrasound examination in some cases, this technique achieves diagnostically acceptable levels of accuracy for fetal brain and abdominal organs, compared with conventional autopsy. It may therefore play a role as a first-line examination before other virtual autopsy techniques are indicated. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- X Kang
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - S C Shelmerdine
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - I Hurtado
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - E Bevilacqua
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - C Hutchinson
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
- UCL Great Ormond Street Institute of Child Health, London, UK
| | - U Mandalia
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - V Segers
- Department of Feto-Pathology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - T Cos Sanchez
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - M M Cannie
- Department of Radiology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
- Department of Radiology, UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - A Carlin
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - N J Sebire
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
- UCL Great Ormond Street Institute of Child Health, London, UK
| | - O J Arthurs
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
- UCL Great Ormond Street Institute of Child Health, London, UK
| | - J C Jani
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
32
|
Sandrini C, Lombardi C, Shearn AIU, Ordonez MV, Caputo M, Presti F, Luciani GB, Rossetti L, Biglino G. Three-Dimensional Printing of Fetal Models of Congenital Heart Disease Derived From Microfocus Computed Tomography: A Case Series. Front Pediatr 2019; 7:567. [PMID: 32039123 PMCID: PMC6985276 DOI: 10.3389/fped.2019.00567] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 12/27/2019] [Indexed: 12/14/2022] Open
Abstract
This article presents a case series of n = 21 models of fetal cardiovascular anatomies obtained from post mortem microfocus computed tomography (micro-CT) data. The case series includes a broad range of diagnoses (e.g., tetralogy of Fallot, hypoplastic left heart syndrome, dextrocardia, double outlet right ventricle, atrio-ventricular septal defect) and cases also had a range of associated extra-cardiac malformations (e.g., VACTERL syndrome, central nervous system anomalies, renal anomalies). All cases were successfully reconstructed from the microfocus computed tomography data, demonstrating the feasibility of the technique and of the protocols, including in-house printing with a desktop 3D printer (Form2, Formlabs). All models were printed in 1:1 scale as well as with the 5-fold magnification, to provide insight into the intra-cardiac structures. Possible uses of the models include education and training.
Collapse
Affiliation(s)
- Camilla Sandrini
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | | | - Andrew I U Shearn
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Maria Victoria Ordonez
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Massimo Caputo
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Francesca Presti
- Division of Obstetrics and Gynecology B, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Giovanni Battista Luciani
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Lucia Rossetti
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - Giovanni Biglino
- Bristol Medical School, Bristol Heart Institute, University of Bristol, Bristol, United Kingdom.,National Heart and Lung Institute, Imperial College London, London, United Kingdom
| |
Collapse
|
33
|
Sandrini C, Rossetti L, Zambelli V, Zanarotti R, Bettinazzi F, Soldá R, Di Pace C, Hoxha S, Ribichini FL, Faggian G, Lombardi C, Luciani GB. Accuracy of Micro-Computed Tomography in Post-mortem Evaluation of Fetal Congenital Heart Disease. Comparison Between Post-mortem Micro-CT and Conventional Autopsy. Front Pediatr 2019; 7:92. [PMID: 30968009 PMCID: PMC6440368 DOI: 10.3389/fped.2019.00092] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2018] [Accepted: 03/01/2019] [Indexed: 11/13/2022] Open
Abstract
Aims: Early prenatal diagnosis of congenital heart disease is feasible. Conventional autopsy is the current gold standard method for post-mortem confirmation. Radiologic techniques alternative to conventional autopsy, such as post-mortem micro-computed tomography, have been proposed in case of limited diagnostic accuracy (i.e., early termination of pregnancy, samples of small dimension or of low weight). The aim of the present study was to define accuracy of micro-computed tomography for post-mortem diagnosis of congenital heart disease in gross anatomy samples. Methods and Results: Fetal heart underwent in-utero prenatal echocardiography and ex-vivo post-mortem evaluation by 9 μm resolution micro-computed tomography and conventional autopsy. For each case, 25 indices of cardiac anatomy were studied by post-mortem micro-computed tomography and conventional autopsy; these were used to compare the two post mortem techniques. Ten samples were examined (gestational age between 12 + 4 and 21 + 6 weeks of gestation). Considering comparable indices, agreement between post-mortem micro-computed tomography and conventional autopsy was of 100% and sensitivity and specificity were of 100%. In "challenging specimens," post-mortem micro-computed tomography diagnoses more indices as compared to conventional autopsy and 84% of "not-diagnostic" indices at conventional autopsy would be diagnostic at post-mortem micro-computed tomography. Conclusion: Micro-computed tomography can be a valid diagnostic alternative to conventional autopsy for post-mortem evaluation of human fetal heart. In addition, it may prove superior to conventional autopsy particularly in cases coming from early termination of pregnancy or in samples of small dimension or of low weight.
Collapse
Affiliation(s)
- Camilla Sandrini
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - Lucia Rossetti
- Division of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - Vanessa Zambelli
- School of Medicine and Surgery, University of Milano Bicocca, Monza, Italy
| | | | - Franca Bettinazzi
- Division of Obstetrics and Gynecology, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Roberta Soldá
- Division of Obstetrics and Gynecology, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | - Concetta Di Pace
- Department of Pathology, Department of Diagnostics and Public Health, University of Verona, Verona, Italy
| | - Stiljan Hoxha
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | | | - Giuseppe Faggian
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| | | | - Giovanni Battista Luciani
- Division of Cardiac Surgery, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, Verona, Italy
| |
Collapse
|
34
|
Blondiaux E, Autret G, Dhombres F, Gonzales M, Audureau E, Clément O, Jouannic JM, Houyel L. Evaluation of septal insertion of atrioventricular valves in fetuses by postmortem 4.7 Tesla cardiac MRI: A feasibility study. Diagn Interv Imaging 2018; 100:109-116. [PMID: 30527913 DOI: 10.1016/j.diii.2018.11.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 10/18/2018] [Accepted: 11/12/2018] [Indexed: 12/01/2022]
Abstract
PURPOSE The purpose of this study was to compare non-invasive high-spatial-resolution postmortem cardiac magnetic resonance imaging (MRI) and autopsy findings for evaluating the septal insertion of atrioventricular valves in fetuses. MATERIALS AND METHODS Five fetal heart specimens including two normal hearts, one heart with complete atrioventricular septal defect (AVSD) and two hearts with linear insertion of atrioventricular valves (LIAVV; gestational age 17 to 34 weeks) were studied with cardiac MRI using a 4.7 T MRI scanner without sample preparation. Three (3D) and two-dimensional (2D) turbo-RARE (rapid imaging with refocused echoes) sequences in four-chamber and left-ventricular long-axis planes were obtained with a minimal isotropic/in-plane resolution of 156μm. Nonparametric tests were performed to compare the distance between insertions of medial leaflets of the atrioventricular valves and the inlet/outlet distance ratio between MRI and autopsy findings in normal, complete AVSD and with linear insertion of atrioventricular valves (LIAVV) fetal hearts. RESULTS Despite apparent differences between LIAVV/normal hearts, no significant differences were found between differential insertion of medial leaflets and inlet/outlet distance ratios with both techniques. Very good to excellent reliability between both techniques was found for differential insertion (ICC: 87.2%; 95% CI: -21.7%, 99.1%) (P=0.963) and inlet/outlet distance ratio (ICC 98.3%; 95%CI: 85.2%, 99.8%) (P=0.537) measurements. CONCLUSION Postmortem cardiac MRI could replace autopsy for assessing normal or abnormal septal insertion of atrioventricular valves in fetuses without requiring specific preparation of the heart.
Collapse
Affiliation(s)
- E Blondiaux
- Laboratoire d'imagerie biomédicale, CNRS 7371, Inserm 1146, department of radiology, Sorbonne université, hôpital Trousseau, hôpitaux universitaires de l'Est parisien, AP-HP, 75012 Paris, France.
| | - G Autret
- Inserm U970, plateforme imageries du vivant, Paris cardiovascular research center, université Paris Descartes, Sorbonne Paris cité, 75015 Paris, France
| | - F Dhombres
- Faculté de médecine, department of fetal medicine, Sorbonne université, hôpital Trousseau, hôpitaux universitaires de l'Est parisien, AP-HP, 75012 Paris, France
| | - M Gonzales
- Faculté de médecine, department of fetal medicine, Sorbonne université, hôpital Trousseau, hôpitaux universitaires de l'Est parisien, AP-HP, 75012 Paris, France
| | - E Audureau
- LIC EA 4393, department of public health, université Paris Est Créteil, hôpital Henri-Mondor, AP-HP, 94000 Créteil, France
| | - O Clément
- Inserm U970, plateforme imageries du vivant, Paris cardiovascular research center, université Paris Descartes, Sorbonne Paris cité, 75015 Paris, France
| | - J-M Jouannic
- Faculté de médecine, department of fetal medicine, Sorbonne université, hôpital Trousseau, hôpitaux universitaires de l'Est parisien, AP-HP, 75012 Paris, France
| | - L Houyel
- Congenital and Pediatric Cardiology Unit, Centre de Référence Maladies Cardiaques Congénitales Complexes-M3C, hôpital Necker-Enfants Malades, AP-HP, 75006 Paris, France; Université Paris-Descartes, Sorbonne Paris Cité, 75005 Paris, France
| |
Collapse
|
35
|
Boult JKR, Apps JR, Hölsken A, Hutchinson JC, Carreno G, Danielson LS, Smith LM, Bäuerle T, Buslei R, Buchfelder M, Virasami AK, Koers A, Arthurs OJ, Jacques TS, Chesler L, Martinez‐Barbera JP, Robinson SP. Preclinical transgenic and patient-derived xenograft models recapitulate the radiological features of human adamantinomatous craniopharyngioma. Brain Pathol 2018; 28:475-483. [PMID: 28481062 PMCID: PMC6099240 DOI: 10.1111/bpa.12525] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Accepted: 04/18/2017] [Indexed: 12/11/2022] Open
Abstract
To assess the clinical relevance of transgenic and patient-derived xenograft models of adamantinomatous craniopharyngioma (ACP) using serial magnetic resonance imaging (MRI) and high resolution post-mortem microcomputed tomography (μ-CT), with correlation with histology and human ACP imaging. The growth patterns and radiological features of tumors arising in Hesx1Cre/+ ;Ctnnb1lox(ex3)/+ transgenic mice, and of patient-derived ACP xenografts implanted in the cerebral cortex, were monitored longitudinally in vivo with anatomical and functional MRI, and by ex vivo μ-CT at study end. Pathological correlates with hematoxylin and eosin stained sections were investigated. Early enlargement and heterogeneity of Hesx1Cre/+ ;Ctnnb1lox(ex3)/+ mouse pituitaries was evident at initial imaging at 8 weeks, which was followed by enlargement of a solid tumor, and development of cysts and hemorrhage. Tumors demonstrated MRI features that recapitulated those of human ACP, specifically, T1 -weighted signal enhancement in the solid tumor component following Gd-DTPA administration, and in some animals, hyperintense cysts on FLAIR and T1 -weighted images. Ex vivo μ-CT correlated with MRI findings and identified smaller cysts, which were confirmed by histology. Characteristic histological features, including wet keratin and calcification, were visible on μ-CT and verified by histological sections of patient-derived ACP xenografts. The Hesx1Cre/+ ;Ctnnb1lox(ex3)/+ transgenic mouse model and cerebral patient-derived ACP xenografts recapitulate a number of the key radiological features of the human disease and provide promising foundations for in vivo trials of novel therapeutics for the treatment of these tumors.
Collapse
Affiliation(s)
- Jessica K. R. Boult
- Division of Radiotherapy and ImagingThe Institute of Cancer ResearchLondonUK
| | - John R. Apps
- Developmental Biology and Cancer Programme, Birth Defects Research Centre, UCL Great Ormond Street Institute of Child HealthUniversity College LondonLondonUK
| | - Annett Hölsken
- Department of NeuropathologyUniversity Hospital Erlangen, Friedrich‐Alexander University Erlangen‐NürnbergErlangenGermany
| | - J. Ciaran Hutchinson
- Histopathology DepartmentGreat Ormond Street Hospital for Children NHS Foundation TrustLondonUK
| | - Gabriela Carreno
- Developmental Biology and Cancer Programme, Birth Defects Research Centre, UCL Great Ormond Street Institute of Child HealthUniversity College LondonLondonUK
| | | | - Laura M. Smith
- Division of Clinical SciencesThe Institute of Cancer ResearchLondonUK
| | - Tobias Bäuerle
- Institute of Radiology, Preclinical Imaging Platform Erlangen (PIPE)University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Rolf Buslei
- Department of NeuropathologyUniversity Hospital Erlangen, Friedrich‐Alexander University Erlangen‐NürnbergErlangenGermany
- Institute of PathologySozialstiftung BambergBambergGermany
| | - Michael Buchfelder
- Department of NeurosurgeryUniversity Hospital Erlangen, Friedrich‐Alexander University Erlangen‐NürnbergErlangenGermany
| | - Alex K. Virasami
- Histopathology DepartmentGreat Ormond Street Hospital for Children NHS Foundation TrustLondonUK
| | - Alexander Koers
- Division of Clinical SciencesThe Institute of Cancer ResearchLondonUK
| | - Owen J. Arthurs
- Histopathology DepartmentGreat Ormond Street Hospital for Children NHS Foundation TrustLondonUK
| | - Thomas S. Jacques
- Developmental Biology and Cancer Programme, Birth Defects Research Centre, UCL Great Ormond Street Institute of Child HealthUniversity College LondonLondonUK
- Histopathology DepartmentGreat Ormond Street Hospital for Children NHS Foundation TrustLondonUK
| | - Louis Chesler
- Division of Clinical SciencesThe Institute of Cancer ResearchLondonUK
| | - Juan Pedro Martinez‐Barbera
- Developmental Biology and Cancer Programme, Birth Defects Research Centre, UCL Great Ormond Street Institute of Child HealthUniversity College LondonLondonUK
| | - Simon P. Robinson
- Division of Radiotherapy and ImagingThe Institute of Cancer ResearchLondonUK
| |
Collapse
|
36
|
Postmortem microfocus computed tomography for early gestation fetuses: a validation study against conventional autopsy. Am J Obstet Gynecol 2018; 218:445.e1-445.e12. [PMID: 29410108 DOI: 10.1016/j.ajog.2018.01.040] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 01/11/2018] [Accepted: 01/23/2018] [Indexed: 11/22/2022]
Abstract
BACKGROUND Perinatal autopsy provides useful clinical information in up to 40% of cases. However, there is a substantial unmet clinical need with regards to postmortem investigation of early gestation fetal loss for parents for whom standard autopsy is either not available or not acceptable. Parents dislike the invasive nature of autopsy, but current clinical imaging techniques do not provide high-enough imaging resolution in small fetuses. We hypothesized that microfocus computed tomography, which is a rapid high-resolution imaging technique, could give accurate diagnostic imaging after early gestation fetal loss. OBJECTIVE The objective of the study was to evaluate the diagnostic accuracy of microfocus computed tomography for noninvasive human fetal autopsy for early gestation fetuses, with the use of conventional autopsy as the reference standard. STUDY DESIGN We compared iodinated whole body microfocus computed tomography in 20 prospectively recruited fetuses (11-21 weeks gestation from 2 centers) with conventional autopsy in a double-blinded manner for a main diagnosis and findings in specific body organs. Fetuses were prepared with 10% formalin/potassium tri-iodide. Images were acquired with a microfocus computed tomography scanner with size-appropriate parameters. Images were evaluated independently by 2 pediatric radiologists, who were blinded to formal perinatal autopsy results, across 40 individual indices to reach consensus. The primary outcome was agreement between microfocus computed tomography and conventional autopsy for overall diagnosis. RESULTS Postmortem whole body fetal microfocus computed tomography gave noninvasive autopsy in minutes, at a mean resolution of 27μm, with high diagnostic accuracy in fetuses at <22 weeks gestation. Autopsy demonstrated that 13 of 20 fetuses had structural abnormalities, 12 of which were also identified by microfocus computed tomography (92.3%). Overall, microfocus computed tomography agreed with overall autopsy findings in 35 of 38 diagnoses (15 true positive, 18 true negative; sensitivity 93.8% [95% confidence interval, 71.7-98.9%], specificity 100% [95% confidence interval, 82.4-100%]), with 100% agreement for body imaging diagnoses. Furthermore, after removal of nondiagnostic indices, there was agreement for 700 of 718 individual body organ indices that were assessed on microfocus computed tomography and autopsy (agreement, 97.5%; 95% confidence interval, 96.1-98.4%), with no overall differences between fetuses at ≤14 or >14 weeks gestation (agreement, 97.2% and 97.9%, respectively). Within first-trimester fetal loss cases (<14 weeks gestation), microfocus computed tomography analysis yielded significantly fewer nondiagnostic indices than autopsy examination (22/440 vs 48/348, respectively; P<.001). CONCLUSION Postmortem whole-body fetal microfocus computed tomography gives noninvasive, detailed anatomic examinations that are achieved in minutes at high resolution. Microfocus computed tomography may be preferable to magnetic resonance imaging in early gestation fetuses and may offer an acceptable method of examination after fetal loss for parents who decline invasive autopsy. This will facilitate autopsy and subsequent discussions between medical professionals who are involved in patient care and counselling for future pregnancies.
Collapse
|
37
|
De Marco E, Vacchiano G, Frati P, La Russa R, Santurro A, Scopetti M, Guglielmi G, Fineschi V. Evolution of post-mortem coronary imaging: from selective coronary arteriography to post-mortem CT-angiography and beyond. Radiol Med 2018; 123:351-358. [PMID: 29357039 DOI: 10.1007/s11547-018-0855-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Accepted: 01/08/2018] [Indexed: 12/17/2022]
Abstract
Since the 1970s, remarkable efforts have been made in the post-mortem coronary study, especially by angiography, as an added tool to diagnose heart-related deaths. In more recent times, post-mortem CT (PMCT) and post-mortem CT-angiography (PMCTA) have become an established practice in numerous forensic units, because of the undeniable advantages these diagnostic instruments can offer: data acquisition times are increasingly fast, costs have become lower and, once acquired, data can be re-utilized and re-evaluated at any given time. This review aims to chart the history of post-mortem cardiac imaging, highlighting its evolution both in terms of methodology and technology as well as the contribution that forensic radiology has been able to offer to forensic pathology, not as an alternative to autopsy but as a guide and aid when performing one. Finally, the latest advances in the study of cardiac deaths are explored, namely by cardiac post-mortem MRI (PMMR), able to visualize all the various stages of a myocardial infarction, post-mortem MRI-angiography (PMMRA), useful in investigating coronary artery pathology and post-mortem cardiac micro-CT, able to provide near-histological levels of myocardial, coronary and valvular detail.
Collapse
Affiliation(s)
- Emidio De Marco
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, Rome, Italy
| | - Giuseppe Vacchiano
- Department of Law, Economics, Management and Quantitative Methods, University of Sannio, Benevento, Italy
| | - Paola Frati
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, Rome, Italy
- Department of Law, Economics, Management and Quantitative Methods, University of Sannio, Benevento, Italy
- Malzoni Clinical-Scientific Institute, Avellino, Italy
| | - Raffaele La Russa
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, Rome, Italy
- Department of Law, Economics, Management and Quantitative Methods, University of Sannio, Benevento, Italy
- Malzoni Clinical-Scientific Institute, Avellino, Italy
- IRCCS Neuromed, Pozzilli, Italy
| | - Alessandro Santurro
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, Rome, Italy
| | - Matteo Scopetti
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, Rome, Italy
| | - Giuseppe Guglielmi
- Department of Radiology, University of Foggia, Viale Luigi Pinto 1, 71100, Foggia, Italy.
| | - Vittorio Fineschi
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, Rome, Italy
- Department of Law, Economics, Management and Quantitative Methods, University of Sannio, Benevento, Italy
- Malzoni Clinical-Scientific Institute, Avellino, Italy
| |
Collapse
|
38
|
Dutch guideline for clinical foetal-neonatal and paediatric post-mortem radiology, including a review of literature. Eur J Pediatr 2018; 177:791-803. [PMID: 29675642 PMCID: PMC5958158 DOI: 10.1007/s00431-018-3135-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 02/05/2018] [Accepted: 03/26/2018] [Indexed: 01/08/2023]
Abstract
UNLABELLED Clinical post-mortem radiology is a relatively new field of expertise and not common practice in most hospitals yet. With the declining numbers of autopsies and increasing demand for quality control of clinical care, post-mortem radiology can offer a solution, or at least be complementary. A working group consisting of radiologists, pathologists and other clinical medical specialists reviewed and evaluated the literature on the diagnostic value of post-mortem conventional radiography (CR), ultrasonography, computed tomography (PMCT), magnetic resonance imaging (PMMRI), and minimally invasive autopsy (MIA). Evidence tables were built and subsequently a Dutch national evidence-based guideline for post-mortem radiology was developed. We present this evaluation of the radiological modalities in a clinical post-mortem setting, including MIA, as well as the recently published Dutch guidelines for post-mortem radiology in foetuses, neonates, and children. In general, for post-mortem radiology modalities, PMMRI is the modality of choice in foetuses, neonates, and infants, whereas PMCT is advised in older children. There is a limited role for post-mortem CR and ultrasonography. In most cases, conventional autopsy will remain the diagnostic method of choice. CONCLUSION Based on a literature review and clinical expertise, an evidence-based guideline was developed for post-mortem radiology of foetal, neonatal, and paediatric patients. What is Known: • Post-mortem investigations serve as a quality check for the provided health care and are important for reliable epidemiological registration. • Post-mortem radiology, sometimes combined with minimally invasive techniques, is considered as an adjunct or alternative to autopsy. What is New: • We present the Dutch guidelines for post-mortem radiology in foetuses, neonates and children. • Autopsy remains the reference standard, however minimal invasive autopsy with a skeletal survey, post-mortem computed tomography, or post-mortem magnetic resonance imaging can be complementary thereof.
Collapse
|
39
|
Morphological features of complex congenital cardiovascular anomalies in fetuses: as evaluated by cast models. ACTA ACUST UNITED AC 2017; 37:596-604. [DOI: 10.1007/s11596-017-1778-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2017] [Revised: 07/10/2017] [Indexed: 12/19/2022]
|
40
|
Stephenson RS, Atkinson A, Kottas P, Perde F, Jafarzadeh F, Bateman M, Iaizzo PA, Zhao J, Zhang H, Anderson RH, Jarvis JC, Dobrzynski H. High resolution 3-Dimensional imaging of the human cardiac conduction system from microanatomy to mathematical modeling. Sci Rep 2017; 7:7188. [PMID: 28775383 PMCID: PMC5543124 DOI: 10.1038/s41598-017-07694-8] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Accepted: 07/03/2017] [Indexed: 12/23/2022] Open
Abstract
Cardiac arrhythmias and conduction disturbances are accompanied by structural remodelling of the specialised cardiomyocytes known collectively as the cardiac conduction system. Here, using contrast enhanced micro-computed tomography, we present, in attitudinally appropriate fashion, the first 3-dimensional representations of the cardiac conduction system within the intact human heart. We show that cardiomyocyte orientation can be extracted from these datasets at spatial resolutions approaching the single cell. These data show that commonly accepted anatomical representations are oversimplified. We have incorporated the high-resolution anatomical data into mathematical simulations of cardiac electrical depolarisation. The data presented should have multidisciplinary impact. Since the rate of depolarisation is dictated by cardiac microstructure, and the precise orientation of the cardiomyocytes, our data should improve the fidelity of mathematical models. By showing the precise 3-dimensional relationships between the cardiac conduction system and surrounding structures, we provide new insights relevant to valvar replacement surgery and ablation therapies. We also offer a practical method for investigation of remodelling in disease, and thus, virtual pathology and archiving. Such data presented as 3D images or 3D printed models, will inform discussions between medical teams and their patients, and aid the education of medical and surgical trainees.
Collapse
Affiliation(s)
- Robert S Stephenson
- Comparative Medicine Lab, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
- School of Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, UK
| | - Andrew Atkinson
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Petros Kottas
- School of Physics and Astronomy, University of Manchester, Manchester, UK
| | - Filip Perde
- National Institute of Legal Medicine, Bucharest, Romania
| | - Fatemeh Jafarzadeh
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Mike Bateman
- The Visible Heart Laboratory, University of Minnesota, Minneapolis, USA
| | - Paul A Iaizzo
- The Visible Heart Laboratory, University of Minnesota, Minneapolis, USA
| | - Jichao Zhao
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Henggui Zhang
- School of Physics and Astronomy, University of Manchester, Manchester, UK
| | - Robert H Anderson
- Institute of Genetic Medicine, University of Newcastle, Newcastle, UK
| | - Jonathan C Jarvis
- School of Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, UK.
| | - Halina Dobrzynski
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK.
| |
Collapse
|
41
|
Pelizzo G, Calcaterra V, Lombardi C, Bussani R, Zambelli V, De Silvestri A, Custrin A, Belgrano M, Zennaro F. Fetal Cardiac Impairment in Nitrofen-Induced Congenital Diaphragmatic Hernia: Postmortem Microcomputed Tomography Imaging Study. Fetal Pediatr Pathol 2017; 36:282-293. [PMID: 28481127 DOI: 10.1080/15513815.2017.1315198] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION We assessed the post-mortem micro-CT utility to evaluate fetal cardiac impairment in nitrofen-induced congenital diaphragmatic hernia (CDH). METHODS At 9.5d postconception (dpc), pregnant rats were exposed to nitrofen. At +18 and +21dpc, fetuses were harvested by cesarean section. Postmortem micro-CT and autopsy were performed. Fetuses were assigned to three experimental groups: Control group (C), Nitrofen group (N, exposition to nitrofen without CDH), CDH group. Cardio-pulmonary indices were evaluated. RESULTS An accurate morphological evaluation of the lung and heart was obtained. Early cardiac impairment was present in the N and CDH groups. At term pregnancy, an increased maximum diameter and decreased minimum diameter of the ventricles and increased interventricular septal thickness were noted in CDH. Histology showed a myocardial "disarray" and an high density of mitotic myocytes in CDH at midgestation. CONCLUSIONS The potential utility of post-mortem fetal micro-CT examination in CDH was introduced. The results highlighted the presence of cardiac adaptation in affected fetuses.
Collapse
Affiliation(s)
- Gloria Pelizzo
- a Children's Hospital, Istituto Mediterraneo di Eccellenza Pediatrica, Pediatric Surgery Unit , Palermo , Italy
| | - Valeria Calcaterra
- b Pediatric Unit, University of Pavia and Fondazione IRCCS Policlinico San Matteo , Pavia , Italy
| | - Claudio Lombardi
- c Department of Radiology , Studio Diagnostico Eco , Vimercate, Milan , Italy
| | - Rossana Bussani
- d University of Trieste, Institute of Pathologic Anatomy , Trieste , Italy
| | - Vanessa Zambelli
- e School of Medicine and Surgery, University of Milano , Milan , Italy
| | - Annalisa De Silvestri
- f Fondazione IRCCS Policlinico San Matteo, Scientific Direction, Biometry & Clinical Epidemiology , Pavia , Italy
| | - Ana Custrin
- d University of Trieste, Institute of Pathologic Anatomy , Trieste , Italy
| | - Manuel Belgrano
- g Department of Radiology , Cattinara Hospital , Trieste , Italy
| | | |
Collapse
|
42
|
Nijkamp J, Sebire N, Bouman K, Korteweg F, Erwich J, Gordijn S. Perinatal death investigations: What is current practice? Semin Fetal Neonatal Med 2017; 22:167-175. [PMID: 28325580 PMCID: PMC7118457 DOI: 10.1016/j.siny.2017.02.005] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Perinatal death (PD) is a devastating obstetric complication. Determination of cause of death helps in understanding why and how it occurs, and it is an indispensable aid to parents wanting to understand why their baby died and to determine the recurrence risk and management in subsequent pregnancy. Consequently, a perinatal death requires adequate diagnostic investigation. An important first step in the analysis of PD is to identify the case circumstances, including relevant details regarding maternal history, obstetric history and current pregnancy (complications are evaluated and recorded). In the next step, placental examination is suggested in all cases, together with molecular cytogenetic evaluation and fetal autopsy. Investigation for fetal-maternal hemorrhage by Kleihauer is also recommended as standard. In cases where parents do not consent to autopsy, alternative approaches such as minimally invasive postmortem examination, postmortem magnetic resonance imaging, and fetal photographs are good alternatives. After all investigations have been performed it is important to combine findings from the clinical review and investigations together, to identify the most probable cause of death and counsel the parents regarding their loss.
Collapse
Affiliation(s)
- J.W. Nijkamp
- Department of Obstetrics and Gynecology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands,Corresponding author. Department of Obstetrics and Gynecology, University Medical Centre Groningen, CB 21, P.O. box 30001, 9700 RB Groningen, The Netherlands.
| | - N.J. Sebire
- Department of Pediatric Pathology, Clinical Molecular Genetics, Great Ormond Street Hospital for Children and UCL Institute of Child Health, London, UK
| | - K. Bouman
- Department of Genetics, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - F.J. Korteweg
- Department of Obstetrics and Gynecology, Martini Hospital, Groningen, The Netherlands
| | - J.J.H.M. Erwich
- Department of Obstetrics and Gynecology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - S.J. Gordijn
- Department of Obstetrics and Gynecology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
43
|
Hutchinson JC, Shelmerdine SC, Simcock IC, Sebire NJ, Arthurs OJ. Early clinical applications for imaging at microscopic detail: microfocus computed tomography (micro-CT). Br J Radiol 2017; 90:20170113. [PMID: 28368658 DOI: 10.1259/bjr.20170113] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Microfocus CT (micro-CT) has traditionally been used in industry and preclinical studies, although it may find new applicability in the routine clinical setting. It can provide high-resolution three-dimensional digital imaging data sets to the same level of detail as microscopic examination without the need for tissue dissection. Micro-CT is already enabling non-invasive detailed internal assessment of various tissue specimens, particularly in breast imaging and early gestational fetal autopsy, not previously possible from more conventional modalities such as MRI or CT. In this review, we discuss the technical aspects behind micro-CT image acquisition, how early work with small animal studies have informed our knowledge of human disease and the imaging performed so far on human tissue specimens. We conclude with potential future clinical applications of this novel and emerging technique.
Collapse
Affiliation(s)
- J Ciaran Hutchinson
- 1 Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,2 UCL Great Ormond Street Institute of Child Health, London, UK
| | - Susan C Shelmerdine
- 2 UCL Great Ormond Street Institute of Child Health, London, UK.,3 Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - Ian C Simcock
- 2 UCL Great Ormond Street Institute of Child Health, London, UK.,3 Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - Neil J Sebire
- 1 Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,2 UCL Great Ormond Street Institute of Child Health, London, UK
| | - Owen J Arthurs
- 2 UCL Great Ormond Street Institute of Child Health, London, UK.,3 Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| |
Collapse
|
44
|
Arthurs OJ, Hutchinson JC, Sebire NJ. Current issues in postmortem imaging of perinatal and forensic childhood deaths. Forensic Sci Med Pathol 2017; 13:58-66. [PMID: 28083782 PMCID: PMC5306347 DOI: 10.1007/s12024-016-9821-x] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/05/2016] [Indexed: 11/27/2022]
Abstract
Perinatal autopsy practice is undergoing a state of change with the introduction of evidence-based cross-sectional imaging, driven primarily by parental choice. In particular, the introduction of post mortem magnetic resonance imaging (PMMR) has helped to advance less-invasive perinatal autopsy in the United Kingdom (UK) and Europe. However, there are limitations to PMMR and other imaging techniques which need to be overcome, particularly with regard to imaging very small fetuses. Imaging is also now increasingly used to investigate particular deaths in childhood, such as suspected non-accidental injury (NAI) and sudden unexpected death in infancy (SUDI). Here we focus on current topical developments the field, with particular emphasis on the application of imaging to perinatal autopsy, and pediatric forensic deaths. Different imaging modalities and their relative advantages and disadvantages are discussed, together with other benefits of more advanced cross-sectional imaging which currently lie in the research domain. Whilst variations in local imaging service provision and need may determine different practice patterns, and access to machines and professionals with appropriate expertise and experience to correctly interpret the findings may limit current practices, we propose that gold standard perinatal and pediatric autopsy services would include complete PMMR imaging prior to autopsy, with PMCT in suspicious childhood deaths. This approach would provide maximal diagnostic yield to the pathologist, forensic investigator and most importantly, the parents.
Collapse
Affiliation(s)
- Owen J Arthurs
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK.
- Institute of Child Health, UCL, London, UK.
| | - John C Hutchinson
- Institute of Child Health, UCL, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - Neil J Sebire
- Institute of Child Health, UCL, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| |
Collapse
|
45
|
Hutchinson JC, Barrett H, Ramsey AT, Haig IG, Guy A, Sebire NJ, Arthurs OJ. Virtual pathological examination of the human fetal kidney using micro-CT. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2016; 48:663-665. [PMID: 26775717 DOI: 10.1002/uog.15859] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 01/08/2016] [Indexed: 06/05/2023]
Affiliation(s)
- J C Hutchinson
- UCL, Institute of Child Health, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - H Barrett
- Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | | | | | - A Guy
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK
| | - N J Sebire
- UCL, Institute of Child Health, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - O J Arthurs
- UCL, Institute of Child Health, London, UK
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK
| |
Collapse
|
46
|
Gignac PM, Kley NJ, Clarke JA, Colbert MW, Morhardt AC, Cerio D, Cost IN, Cox PG, Daza JD, Early CM, Echols MS, Henkelman RM, Herdina AN, Holliday CM, Li Z, Mahlow K, Merchant S, Müller J, Orsbon CP, Paluh DJ, Thies ML, Tsai HP, Witmer LM. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues. J Anat 2016; 228:889-909. [PMID: 26970556 PMCID: PMC5341577 DOI: 10.1111/joa.12449] [Citation(s) in RCA: 297] [Impact Index Per Article: 37.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/05/2016] [Indexed: 12/13/2022] Open
Abstract
Morphologists have historically had to rely on destructive procedures to visualize the three‐dimensional (3‐D) anatomy of animals. More recently, however, non‐destructive techniques have come to the forefront. These include X‐ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard‐tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT‐based research is the use of chemical agents to render visible, and differentiate between, soft‐tissue structures in X‐ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine‐based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine‐based, contrast‐enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting‐edge applications of diffusible iodine‐based contrast‐enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward.
Collapse
Affiliation(s)
- Paul M Gignac
- Department of Anatomy and Cell Biology, Oklahoma State University Center for Health Sciences, Tulsa, OK, USA
| | - Nathan J Kley
- Department of Anatomical Sciences, Stony Brook University, Stony Brook, NY, USA
| | - Julia A Clarke
- Department of Geological Sciences, Jackson School of Geosciences, The University of Texas at Austin, Austin, TX, USA
| | - Matthew W Colbert
- Department of Geological Sciences, Jackson School of Geosciences, The University of Texas at Austin, Austin, TX, USA
| | | | - Donald Cerio
- Department of Biological Sciences, Ohio University, Athens, OH, USA
| | - Ian N Cost
- Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, MO, USA
| | - Philip G Cox
- Department of Archaeology, University of York and Hull York Medical School, York, UK
| | - Juan D Daza
- Department of Biological Sciences, Sam Houston State University, Huntsville, TX, USA
| | | | | | - R Mark Henkelman
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| | - A Nele Herdina
- Department of Theoretical Biology, University of Vienna, Vienna, Austria
| | - Casey M Holliday
- Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, MO, USA
| | - Zhiheng Li
- Department of Geological Sciences, Jackson School of Geosciences, The University of Texas at Austin, Austin, TX, USA
| | - Kristin Mahlow
- Museum für Naturkunde, Leibniz-Institut für Evolutions- und Biodiversitätforschung an der Humboldt-Universität zu Berlin, Berlin, Germany
| | - Samer Merchant
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT, USA
| | - Johannes Müller
- Museum für Naturkunde, Leibniz-Institut für Evolutions- und Biodiversitätforschung an der Humboldt-Universität zu Berlin, Berlin, Germany
| | - Courtney P Orsbon
- Department of Organismal Biology and Anatomy, The University of Chicago, Chicago, IL, USA
| | - Daniel J Paluh
- Department of Biology, Villanova University, Villanova, PA, USA
| | - Monte L Thies
- Department of Biological Sciences, Sam Houston State University, Huntsville, TX, USA
| | - Henry P Tsai
- Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, MO, USA.,Department of Ecology and Evolutionary Biology, Brown University, Providence, RI, USA
| | | |
Collapse
|