1
|
Gembicki M, Welp A, Scharf JL, Dracopoulos C, Weichert J. Application of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) in Twin Pregnancies: Half the Work or Twice the Effort? Cureus 2023; 15:e38052. [PMID: 37228519 PMCID: PMC10207972 DOI: 10.7759/cureus.38052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/24/2023] [Indexed: 05/27/2023] Open
Abstract
OBJECTIVE To assess the performance of fetal intelligent navigation echocardiography (FINE, 5D Heart™) for automated volumetric investigation of the fetal heart in twin pregnancies. METHODS Three hundred twenty-eight twin fetuses underwent fetal echocardiography in the second and third trimesters. Spatiotemporal image correlation (STIC) volumes were obtained for a volumetric investigation. The volumes were analyzed using the FINE software, and the data were investigated regarding image quality and many properly reconstructed planes. RESULTS Three hundred and eight volumes underwent final analysis. 55.8% of the included pregnancies were dichorionic twin pregnancies, and 44.2% were monochorionic twin pregnancies. The mean gestational age (GA) was 22.1 weeks, and the mean maternal BMI was 27.3 kg/m2. The STIC-volume acquisition was successful in 100.0% and 95.5% of cases. The overall depiction rates of FINE were 96.5% (twin 1) and 94.7% (twin 2), respectively (p = 0.0849, not significant). In 95.9% (twin 1) and 93.9% (twin 2), at least 7 planes were reconstructed properly (p = 0.6056, not significant). CONCLUSION Our results indicate that the FINE technique used in twin pregnancies is reliable. No significant difference between the depiction rates of twin 1 and twin 2 could be detected. In addition, the depiction rates are as high as those derived from singleton pregnancies. Due to the challenges of fetal echocardiography in twin pregnancies (i.e., greater rates of cardiac anomaly and more difficult scans), the FINE technique might be a valuable tool to improve the quality of medical care in those pregnancies.
Collapse
Affiliation(s)
- Michael Gembicki
- Obstetrics and Gynaecology, Universitätsklinikum Schleswig-Holstein, Luebeck, DEU
| | - Amrei Welp
- Obstetrics and Gynaecology, Universitätsklinikum Schleswig-Holstein, Luebeck, DEU
| | - Jann Lennard Scharf
- Obstetrics and Gynaecology, Universitätsklinikum Schleswig-Holstein, Luebeck, DEU
| | | | - Jan Weichert
- Obstetrics and Gynaecology, Universitätsklinikum Schleswig-Holstein, Luebeck, DEU
| |
Collapse
|
2
|
Swor K, Yeo L, Tarca AL, Jung E, Romero R. Fetal intelligent navigation echocardiography (FINE) has superior performance compared to manual navigation of the fetal heart by non-expert sonologists. J Perinat Med 2022; 51:477-491. [PMID: 36474319 PMCID: PMC10164033 DOI: 10.1515/jpm-2022-0387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 10/15/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVES Manual and intelligent navigation (i.e. fetal intelligent navigation echocardiography or FINE) by the operator are two methods to obtain standard fetal cardiac views from spatiotemporal image correlation (STIC) volumes. The objective was to compare the performance between manual and intelligent navigation (FINE) of the fetal heart by non-expert sonologists. METHODS In this prospective observational study, ten sonologists underwent formal training on both navigational methods. Subsequently, they were tested on their ability to obtain nine cardiac views from five STIC volumes of normal fetal hearts (19-28 gestational weeks) using such methods. The following parameters were determined for both methods: (1) success rate of obtaining nine cardiac views; (2) mean time to obtain nine cardiac views per sonologist; and (3) maximum number of cardiac views successfully obtained for each STIC volume. RESULTS All fetal cardiac images obtained from 100 STIC volumes (50 for each navigational method) were reviewed by an expert in fetal echocardiography. Compared to manual navigation, FINE was associated with a significantly: (1) higher success rate of obtaining eight (excluding the abdomen view) appropriate cardiac views (92-100% vs. 56-88%; all p<0.05); (2) shorter mean time (minute:seconds) to obtain nine cardiac views (2:11 ± 0:37 vs. 15:49 ± 7:44; p<0.0001); and (3) higher success rate of obtaining all nine cardiac views for a given STIC volume (86 vs. 14%; p<0.001). CONCLUSIONS When performed by non-expert sonologists, intelligent navigation (FINE) had a superior performance compared to manual navigation of the normal fetal heart. Specifically, FINE obtained appropriate fetal cardiac views in 92-100% of cases.
Collapse
Affiliation(s)
- Katie Swor
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Detroit Medical Center, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Lami Yeo
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Detroit Medical Center, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Adi L Tarca
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA.,Department of Computer Science, College of Engineering, Wayne State University, Detroit, MI, USA
| | - Eunjung Jung
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Roberto Romero
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD, Detroit, MI, USA.,Detroit Medical Center, Detroit, MI, USA.,Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA.,Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA.,Center for Molecular Medicine and Genetics, Wayne State University, Detroit, MI, USA
| |
Collapse
|
3
|
Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode. J Clin Med 2022; 11:jcm11144062. [PMID: 35887826 PMCID: PMC9320472 DOI: 10.3390/jcm11144062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 07/09/2022] [Accepted: 07/12/2022] [Indexed: 11/17/2022] Open
Abstract
(1) Objective: To scrutinize the reliability and the clinical value of routinely used fetal intelligent navigation echocardiography (FINE) static mode (5DHeartStatic™) for accelerated semiautomatic volumetric assessment of the normal fetal heart. (2) Methods: In this study, a total of 296 second and third trimester fetuses were examined by targeted ultrasound. Spatiotemporal image correlation (STIC) volumes of the fetal heart were acquired for further volumetric assessment. In addition, all fetal hearts were scanned by a fast acquisition time volume (1 s). The volumes were analyzed using the FINE software. The data were investigated regarding the number of properly reconstructed planes and cardiac axis. (3) Results: A total of 257 volumes were included for final analysis. The mean gestational age (GA) was 23.9 weeks (14.3 to 37.7 weeks). In 96.9 (standard acquisition time, FINE standard mode) and 94.2% (fast acquisition time, FINE static mode) at least seven planes were reconstructed properly (p = 0.0961, not significant). Regarding the overall depiction rate, the standard mode was able to reconstruct 96.9% of the planes properly, whereas the static mode showed 95.2% of the planes (p = 0.0098). Moreover, there was no significant difference between the automatic measurement of the cardiac axis (37.95 + 9.14 vs. 38.00 + 8.92 degrees, p = 0.8827, not significant). (4) Conclusions: Based on our results, the FINE static mode technique is a reliable method. It provides similar information of the cardiac anatomy compared to conventional STIC volumes assessed by the FINE method. The FINE static mode has the potential to minimize the influence of motion artifacts during volume acquisition and might therefore be helpful concerning volumetric cardiac assessment in daily routine.
Collapse
|
4
|
Yeo L, Romero R. New and advanced features of fetal intelligent navigation echocardiography (FINE) or 5D heart. J Matern Fetal Neonatal Med 2022; 35:1498-1516. [PMID: 32375528 PMCID: PMC10544755 DOI: 10.1080/14767058.2020.1759538] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 04/20/2020] [Indexed: 12/19/2022]
Abstract
Congenital heart disease (CHD) is the leading organ-specific birth defect, as well as the leading cause of infant morbidity and mortality from congenital malformations. Therefore, a comprehensive screening examination of the fetal heart should be performed in all women to maximize the detection of CHD. Four-dimensional sonography with spatiotemporal image correlation (STIC) technology displays a cine loop of a complete single cardiac cycle in motion. A novel method known as Fetal Intelligent Navigation Echocardiography (or FINE) was previously developed to interrogate STIC volume datasets using "intelligent navigation" technology. Such method allows the automatic display of nine standard fetal echocardiography views required to diagnose most cardiac defects. FINE considerably simplifies fetal cardiac examinations and reduces operator dependency. It has both high sensitivity and specificity for the detection of CHD. Indeed, FINE has been integrated into several commercially available ultrasound platforms.Recently, eight novel and advanced features have been developed for the FINE method and they will be described herein. Such features can be categorized based upon their broad goals. The first goal is to simplify FINE further, and consists of the following features: (1) Auto fetal positioning (or FINE align); (2) Skip points; (3) Predictive cursor; (4) Static mode volume; and (5) Breech sweep. The second goal is to allow quantitative measurements to be performed on the cardiac views generated by FINE: (6) Automatic cardiac axis; and (7) Cardiac biometry. Finally, the last goal is to improve the success of obtaining fetal echocardiography view(s); and consists of (8) Maestro planar navigation.
Collapse
Affiliation(s)
- Lami Yeo
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Detroit, MI, USA
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Roberto Romero
- Perinatology Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD and Detroit, MI, USA
- Detroit Medical Center, Detroit, MI, USA
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA
- Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI, USA
- Center for Molecular Medicine and Genetics, Wayne State University, Detroit, MI, USA
| |
Collapse
|
5
|
DeVore GR, Cuneo B, Klas B, Satou G, Sklansky M. Comprehensive Evaluation of Fetal Cardiac Ventricular Widths and Ratios Using a 24-Segment Speckle Tracking Technique. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:1039-1047. [PMID: 30280404 DOI: 10.1002/jum.14792] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 07/17/2018] [Accepted: 07/22/2018] [Indexed: 06/08/2023]
Abstract
INTRODUCTION This study was conducted to evaluate the 24-segment transverse widths of the right and left ventricles distributed from the base to the apex of the ventricular chambers and compute the right ventricular (RV)/left ventricular (LV) ratios for each segment. METHODS Two hundred control fetuses were examined between 20 and 40 weeks' gestation. Using offline speckle-tracking software, the 24 end-diastolic transverse widths were computed and the RV/LV ratios were regressed against 7 independent variables related to the size, weight, and age of the fetuses. Five fetuses with coarctation of the aorta and 5 fetuses with pulmonary stenosis were examined to exemplify the utility of these measurements. FINDINGS The 24-segment transverse widths were associated with changes in fetal size, weight, and age. Regression equations were developed to describe these changes with R2 values between .5 and .82. The measurements were normally distributed (Shapiro-Wilk > 0.5). The RV/LV ratio for the 24 segments did not strongly correlate (R2 = .001 to -.2) with fetal size, weight, or gestational age. Fetuses with coarctation of the aorta and pulmonary stenosis demonstrated characteristic changes in the 24-segment transverse widths and the RV/LV ratios in the basal (segments 1-8), mid (segments 9-16) and apical (segments 17-24) sections of the ventricles. CONCLUSIONS The 24-segment transverse widths of the right and left ventricles and the RV/LV ratios provide a comprehensive method to examine the width of the ventricular chambers.
Collapse
Affiliation(s)
- Greggory R DeVore
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
- Fetal Diagnostic Centers, Pasadena, Tarzana, and Lancaster, California, USA
| | - Bettina Cuneo
- Division of Cardiology, Department of Pediatrics, Children's Hospital Colorado, University of Colorado School of Medicine, Aurora, Colorado, USA
| | | | - Gary Satou
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| | - Mark Sklansky
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| |
Collapse
|
6
|
Yeo L, Markush D, Romero R. Prenatal diagnosis of tetralogy of Fallot with pulmonary atresia using: Fetal Intelligent Navigation Echocardiography (FINE). J Matern Fetal Neonatal Med 2018; 32:3699-3702. [PMID: 30001653 DOI: 10.1080/14767058.2018.1484088] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Tetralogy of Fallot with pulmonary atresia, a severe form of tetralogy of Fallot, is characterized by the absence of flow from the right ventricle to the pulmonary arteries. This cardiac abnormality is challenging and complex due to its many different anatomic variants. The main source of variability is the pulmonary artery anatomy, ranging from well-formed, confluent pulmonary artery branches to completely absent native pulmonary arteries replaced by major aorto-pulmonary collateral arteries (MAPCAs) that provide all of the pulmonary blood flow. Since the four-chamber view is usually normal on prenatal sonography, the diagnosis may be missed unless additional cardiac views are studied. Fetal Intelligent Navigation Echocardiography (FINE) is a novel method developed recently that allows automatic generation of nine standard fetal echocardiography views in normal hearts by applying "intelligent navigation" technology to spatiotemporal image correlation volume datasets. We report herein for the first time, two different cases of tetralogy of Fallot with pulmonary atresia having variable sources of pulmonary blood flow in which the prenatal diagnosis was made successfully using the FINE method. Virtual Intelligent Sonographer Assistance (VIS-Assistance®) and automatic labeling (both features of FINE) were very helpful in making such diagnosis.
Collapse
Affiliation(s)
- Lami Yeo
- a Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research , Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health , Bethesda , MD and Detroit , MI , USA.,b Detroit Medical Center , Hutzel Women's Hospital , Detroit , MI , USA.,c Department of Obstetrics and Gynecology , Wayne State University School of Medicine , Detroit , MI , USA
| | - Dor Markush
- d Department of Pediatrics , Wayne State University School of Medicine, Children's Hospital of Michigan , Detroit , MI , USA
| | - Roberto Romero
- a Perinatology Research Branch, Program for Perinatal Research and Obstetrics, Division of Intramural Research , Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health , Bethesda , MD and Detroit , MI , USA.,e Department of Obstetrics and Gynecology , University of Michigan , Ann Arbor , MI , USA.,f Department of Epidemiology & Biostatistics , Michigan State University , East Lansing , MI , USA.,g Center for Molecular Medicine and Genetics , Wayne State University , Detroit , MI , USA
| |
Collapse
|