1
|
Simcock IC, Arthurs OJ, Hutchinson JC, Sebire NJ, Jacques TS, Sekar T, Shelmerdine SC. Impact of non-invasive post-mortem micro-CT imaging on a fetal autopsy service: a single centre retrospective study. Clin Radiol 2024; 79:791-798. [PMID: 39068113 DOI: 10.1016/j.crad.2024.06.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 06/25/2024] [Accepted: 06/30/2024] [Indexed: 07/30/2024]
Abstract
AIM To evaluate the impact of a new, less-invasive micro-computed tomography (CT) service on autopsy service provision. We recorded parental consent, type of autopsy performed, autopsy reporting times and time taken for the body to be released from the mortuary. MATERIALS AND METHODS A retrospective, single-centre case series was conducted for all perinatal deaths since the introduction of our micro-CT service in 2016, with a detailed review of records extracted from 2019 and 2021. Fetal demographics (gestational age, weight), type of autopsy conducted, and the time taken from receiving the body to releasing the body and issuing a final report were recorded. RESULTS Micro-CT imaging uptake increased to over two hundred cases/year by 2021. Overall, invasive autopsies reduced from (45.8%, 196/428; 2019) to (32.1%, 125/390; 2021) with an equivalent rise in less-invasive autopsy from 54.2% (232/428;2019) to 67.9% (265/390;2019). Offering a micro-CT service resulted in an increase in consent to imaging-based autopsies from (76.9%, 329/428;2019) to (87.2%, 340/390;2021). Micro-CT has become the most common post-mortem imaging performed in our institution at 54.4% (212/251;2021), although the body preparation time from the tissue staining required has increased the time to provide an autopsy report to 17 days and release of the body to 18 days. CONCLUSION Our study shows that introducing a micro-CT post-mortem imaging service was associated with reduced use of conventional invasive procedures, despite a slight increase in turnaround times. Understanding these factors and continued improvements in micro-CT service delivery will help make this accessible to a wider population in the future.
Collapse
Affiliation(s)
- I C Simcock
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK; UCL Great Ormond Street Institute of Child Health, 30 Guildford Street, London, WC1N 3EH, UK; NIHR Great Ormond Street Hospital Biomedical Research Centre, 30 Guildford Street, London, WC1N 3EH, UK.
| | - O J Arthurs
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK; UCL Great Ormond Street Institute of Child Health, 30 Guildford Street, London, WC1N 3EH, UK; NIHR Great Ormond Street Hospital Biomedical Research Centre, 30 Guildford Street, London, WC1N 3EH, UK.
| | - J C Hutchinson
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK.
| | - N J Sebire
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK; UCL Great Ormond Street Institute of Child Health, 30 Guildford Street, London, WC1N 3EH, UK; NIHR Great Ormond Street Hospital Biomedical Research Centre, 30 Guildford Street, London, WC1N 3EH, UK.
| | - T S Jacques
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK.
| | - T Sekar
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK.
| | - S C Shelmerdine
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK.
| |
Collapse
|
2
|
Ibarra Vilar P, De Luca L, Badr DA, Cos Sanchez T, Carlin A, Lecomte S, Jani JC, Kang X. Learning curve for fetal postmortem ultrasound. Prenat Diagn 2024; 44:15-27. [PMID: 38117025 DOI: 10.1002/pd.6482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 11/10/2023] [Accepted: 11/25/2023] [Indexed: 12/21/2023]
Abstract
OBJECTIVE To determine the learning curve of fetal postmortem ultrasound (PMUS) and evaluate the evolution of its diagnostic performance over the past 8 years. METHODS PMUS was performed by two fetal medicine specialists and two experts on 100 unselected fetuses of 12-38 weeks of gestation in a prospective, double-blind manner. 21 pre-defined internal structures were analyzed consecutively by the trainee alone and the expert, with a comparison of diagnosis and immediate feedback. The learning curves for examination duration, non-recognition of structures and final diagnoses were computed using cumulative summation analysis. Secondly, the expert PMUS diagnostic accuracy using autopsy as the gold standard was compared to the previously published data. RESULTS The trainees reached expert level of PMUS at 28-36 cases for examination duration (12.1 ± 5.2 min), non-diagnostic rate (6.5%, 137/2100), and abnormality diagnosis. In a group of 33 fetuses ≥20 weeks who had an autopsy, the experts PMUS performance was improved after 8 years with a reduction of all organs non-diagnostic rate (6.5 %VS 11.4%, p < 0.01) and higher sensitivity for the heart (100% VS 40.9%, p < 0.01) and the abdomen (100%VS 56.5%, p < 0.05). CONCLUSION PMUS offers a short learning curve for fetal medicine specialists and on-going improvement of diagnostic accuracy over time.
Collapse
Affiliation(s)
- Patricia Ibarra Vilar
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Laura De Luca
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Dominique A Badr
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Teresa Cos Sanchez
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Andrew Carlin
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Sophie Lecomte
- Department of Feto-Pathology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Jacques C Jani
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Xin Kang
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
3
|
Simcock IC, Shelmerdine SC, Hutchinson JC, Sebire NJ, Arthurs OJ. Body weight-based iodinated contrast immersion timing for human fetal postmortem microfocus computed tomography. BJR Open 2024; 6:tzad006. [PMID: 38352185 PMCID: PMC10860501 DOI: 10.1093/bjro/tzad006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/27/2023] [Accepted: 10/13/2023] [Indexed: 02/16/2024] Open
Abstract
Objectives The aim of this study was to evaluate the length of time required to achieve full iodination using potassium tri-iodide as a contrast agent, prior to human fetal postmortem microfocus computed tomography (micro-CT) imaging. Methods Prospective assessment of optimal contrast iodination was conducted across 157 human fetuses (postmortem weight range 2-298 g; gestational age range 12-37 weeks), following micro-CT imaging. Simple linear regression was conducted to analyse which fetal demographic factors could produce the most accurate estimate for optimal iodination time. Results Postmortem body weight (r2 = 0.6435) was better correlated with iodination time than gestational age (r2 = 0.1384), producing a line of best fit, y = [0.0304 × body weight (g)] - 2.2103. This can be simplified for clinical use whereby immersion time (days) = [0.03 × body weight (g)] - 2.2. Using this formula, for example, a 100-g fetus would take 5.2 days to reach optimal contrast enhancement. Conclusions The simplified equation can now be used to provide estimation times for fetal contrast preparation time prior to micro-CT imaging and can be used to manage service throughput and parental expectation for return of their fetus. Advances in knowledge A simple equation from empirical data can now be used to estimate preparation time for human fetal postmortem micro-CT imaging.
Collapse
Affiliation(s)
- Ian C Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
| | - Susan C Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
| | - John Ciaran Hutchinson
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
- Department of Histopathology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
| | - Neil J Sebire
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
- Department of Histopathology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
| | - Owen J Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London WC1N 3JH, United Kingdom
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London WC1N 1EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London WC1N 1EH, United Kingdom
| |
Collapse
|
4
|
Simcock IC, Lamouroux A, Sebire NJ, Shelmerdine SC, Arthurs OJ. Less-invasive autopsy for early pregnancy loss. Prenat Diagn 2023; 43:937-949. [PMID: 37127547 DOI: 10.1002/pd.6361] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 05/03/2023]
Abstract
Autopsy investigations provide valuable information regarding fetal death that can assist in the parental bereavement process, and influence future pregnancies, but conventional autopsy is often declined by parents because of its invasive approach. This has led to the development of less-invasive autopsy investigations based on imaging technology to provide a more accessible and acceptable choice for parents when investigating their loss. Whilst the development and use of more conventional clinical imaging techniques (radiographs, CT, MRI, US) are well described in the literature for fetuses over 20 weeks of gestational age, these investigations have limited diagnostic accuracy in imaging smaller fetuses. Techniques such as ultra-high-field MRI (>3T) and micro-focus computed tomography have been shown to have higher diagnostic accuracy whilst still being acceptable to parents. By further developing and increasing the availability of these more innovative imaging techniques, parents will be provided with a greater choice of acceptable options to investigate their loss, which may in turn increase their uptake. We provide a narrative review focussing on the development of high-resolution, non-invasive imaging techniques to evaluate early gestational pregnancy loss.
Collapse
Affiliation(s)
- Ian C Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Audrey Lamouroux
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Obstetrical Gynaecology Department, Nîmes University Hospital, Nîmes, France
- Clinical Genetics Department, Montpellier University Hospital, Montpellier, France
- ICAR Research Team, LIRMM, CNRS and Charles Coulomb Laboratory, UMR 5221 CNRS-UM, BNIF User Facility Imaging, University of Montpellier, Nîmes and Montpellier, Montpellier, France
| | - Neil J Sebire
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children, London, UK
| | - Susan C Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Owen J Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- UCL Great Ormond Street Institute of Child Health, Great Ormond Street Hospital for Children, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| |
Collapse
|
5
|
O'Keefe H, Shenfine R, Brown M, Beyer F, Rankin J. Are non-invasive or minimally invasive autopsy techniques for detecting cause of death in prenates, neonates and infants accurate? A systematic review of diagnostic test accuracy. BMJ Open 2023; 13:e064774. [PMID: 36609326 PMCID: PMC9827258 DOI: 10.1136/bmjopen-2022-064774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 12/04/2022] [Indexed: 01/08/2023] Open
Abstract
OBJECTIVES To assess the diagnostic accuracy of non-invasive or minimally invasive autopsy techniques in deaths under 1 year of age. DESIGN This is a systematic review of diagnostic test accuracy. The protocol is registered on PROSPERO. PARTICIPANTS Deaths from conception to one adjusted year of age. SEARCH METHODS MEDLINE (Ovid), EMBASE (Ovid), CINAHL (EBSCO), the Cochrane Library, Scopus and grey literature sources were searched from inception to November 2021. DIAGNOSTIC TESTS Non-invasive or minimally invasive diagnostic tests as an alternative to traditional autopsy. DATA COLLECTION AND ANALYSIS Studies were included if participants were under one adjusted year of age, with index tests conducted prior to the reference standard.Data were extracted from eligible studies using piloted forms. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies-2. A narrative synthesis was conducted following the Synthesis without Meta-Analysis guidelines. Vote counting was used to assess the direction of effect. MAIN OUTCOME MEASURES Direction of effect was expressed as percentage of patients per study. FINDINGS We included 54 direct evidence studies (68 articles/trials), encompassing 3268 cases and eight index tests. The direction of effect was positive for postmortem ultrasound and antenatal echography, although with varying levels of success. Conversely, the direction of effect was against virtual autopsy. For the remaining tests, the direction of effect was inconclusive.A further 134 indirect evidence studies (135 articles/trials) were included, encompassing 6242 perinatal cases. The addition of these results had minimal impact on the direct findings yet did reveal other techniques, which may be favourable alternatives to autopsy.Seven trial registrations were included but yielded no results. CONCLUSIONS Current evidence is insufficient to make firm conclusions about the generalised use of non-invasive or minimally invasive autopsy techniques in relation to all perinatal population groups.PROSPERO registration numberCRD42021223254.
Collapse
Affiliation(s)
- Hannah O'Keefe
- NIHR Innovation Observatory, Newcastle University, Newcastle upon Tyne, UK
- Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
| | - Rebekka Shenfine
- Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
| | - Melissa Brown
- Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
| | - Fiona Beyer
- NIHR Innovation Observatory, Newcastle University, Newcastle upon Tyne, UK
- Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
| | - Judith Rankin
- Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
| |
Collapse
|
6
|
Shelmerdine SC, Arthurs OJ. Post-mortem perinatal imaging: what is the evidence? Br J Radiol 2022:20211078. [PMID: 35451852 DOI: 10.1259/bjr.20211078] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Post-mortem imaging for the investigation of perinatal deaths is an acceptable tool amongst parents and religious groups, enabling a less invasive autopsy examination. Nevertheless, availability is scarce nationwide, and there is some debate amongst radiologists regarding the best practice and optimal protocols for performing such studies. Much of the published literature to date focusses on single centre experiences or interesting case reports. Diagnostic accuracy studies are available for a variety of individual imaging modalities (e.g. post-mortem CT, MRI, ultrasound and micro-CT), however, assimilating this information is important when attempting to start a local service.In this article, we present a comprehensive review summarising the latest research, recently published international guidelines, and describe which imaging modalities are best suited for specific indications. When the antenatal clinical findings are not supported by the post-mortem imaging, we also suggest how and when an invasive autopsy may be considered. In general, a collaborative working relationship within a multidisciplinary team (consisting of radiologists, radiographers, the local pathology department, mortuary staff, foetal medicine specialists, obstetricians and bereavement midwives) is vital for a successful service.
Collapse
Affiliation(s)
- Susan C Shelmerdine
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,UCL Great Ormond Street Institute of Child Health, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre, 30 Guilford Street, Bloomsbury, London, UK.,Department of Radiology, St. George's Hospital, Blackshaw Road, London, UK
| | - Owen J Arthurs
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.,UCL Great Ormond Street Institute of Child Health, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre, 30 Guilford Street, Bloomsbury, London, UK
| |
Collapse
|
7
|
Tang H, Zhang Y, Dai C, Ru T, Li J, Chen J, Zhang B, Zhou K, Lv P, Liu R, Zhou Q, Zheng M. Postmortem 9.4-T MRI for Fetuses With Congenital Heart Defects Diagnosed in the First Trimester. Front Cardiovasc Med 2022; 8:764587. [PMID: 35155595 PMCID: PMC8830519 DOI: 10.3389/fcvm.2021.764587] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 12/24/2021] [Indexed: 11/13/2022] Open
Abstract
ObjectiveTo evaluate the feasibility of 9. 4-T postmortem MRI (pm-MRI) for assessment of major congenital heart defects (CHD) cases terminated in the early stage of gestation.MethodsFetuses with CHD detected by the detailed first-trimester ultrasound scan and terminated before 18 gestational weeks were recruited between January 2018 and June 2020. All fetuses were offered 9.4-T pm-MRI examinations and those terminated over 13+6 weeks were offered conventional autopsies simultaneously. Findings of pm-MRI were compared with those of conventional autopsy and prenatal ultrasound.ResultsA total of 19 fetuses with major CHD were analyzed, including 6 cases of the atrioventricular septal defect, 5 cases of Tetralogy of Fallot, 3 cases of hypoplastic left heart syndrome, 1 case of tricuspid atresia, 1 case of transposition of the great arteries, 1 case of severe tricuspid regurgitation, and 2 cases of complex CHD. Pm-MRI had concordant findings in 73.7% (14/19) cases, discordant findings in 15.8% (3/19) cases, and additional findings in 10.5% (2/19) cases when compared with prenatal ultrasound. Pm-MRI findings were concordant with autopsy in all 8 CHD cases terminated over 13+6 weeks.ConclusionIt is feasible to exhibit the structure of fetal heart terminated in the first trimester clearly on 9.4-T pm-MRI with an optimized scanning protocol. High-field pm-MRI could provide medical imaging information of CHD for those terminated in the early stage of gestation, especially for those limited by conventional autopsy.
Collapse
Affiliation(s)
- Huirong Tang
- Department of Obstetrics and Gynecology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Yan Zhang
- Department of Obstetrics and Gynecology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Chenyan Dai
- Department of Obstetrics and Gynecology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Tong Ru
- Department of Obstetrics and Gynecology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Jie Li
- Department of Obstetrics and Gynecology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Jieyu Chen
- Department of Pathology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Bing Zhang
- Department of Radiology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Kefeng Zhou
- Department of Radiology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Pin Lv
- Department of Radiology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Renyuan Liu
- Department of Radiology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Qing Zhou
- Department of Cardiac Surgery, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
| | - Mingming Zheng
- Department of Obstetrics and Gynecology, The Affiliated Drum and Tower Hospital of Medical School of Nanjing University, Nanjing, China
- *Correspondence: Mingming Zheng
| |
Collapse
|
8
|
Gupta N, Martinez-Rios C, El Demellawy D, Barrowman N, Miller E. Diagnostic Evaluation of the Posterior Fossa with Antenatal and Post-Mortem MRI: An Unfolded View. JOURNAL OF FETAL MEDICINE 2022. [DOI: 10.1007/s40556-021-00329-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
9
|
Simcock IC, Shelmerdine SC, Langan D, Anna G, Sebire NJ, Arthurs OJ. Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration. BMC Med Imaging 2021; 21:128. [PMID: 34429085 PMCID: PMC8383392 DOI: 10.1186/s12880-021-00658-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 08/01/2021] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Current clinical post-mortem imaging techniques do not provide sufficiently high-resolution imaging for smaller fetuses after pregnancy loss. Post-mortem micro-CT is a non-invasive technique that can deliver high diagnostic accuracy for these smaller fetuses. The purpose of the study is to identify the main predictors of image quality for human fetal post-mortem micro-CT imaging. METHODS Human fetuses were imaged using micro-CT following potassium tri-iodide tissue preparation, and axial head and chest views were assessed for image quality on a Likert scale by two blinded radiologists. Simple and multivariable linear regression models were performed with demographic details, iodination, tissue maceration score and imaging parameters as predictor variables. RESULTS 258 fetuses were assessed, with median weight 41.7 g (2.6-350 g) and mean gestational age 16 weeks (11-24 weeks). A high image quality score (> 6.5) was achieved in 95% of micro-CT studies, higher for the head (median = 9) than chest (median = 8.5) imaging. The strongest negative predictors of image quality were increasing maceration and body weight (p < 0.001), with number of projections being the best positive imaging predictor. CONCLUSIONS High micro-CT image quality score is achievable following early pregnancy loss despite fetal maceration, particularly in smaller fetuses where conventional autopsy may be particularly challenging. These findings will help establish clinical micro-CT imaging services, addressing the need for less invasive fetal autopsy methods.
Collapse
Affiliation(s)
- Ian Craig Simcock
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK.
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK.
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK.
| | - Susan Cheng Shelmerdine
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Dean Langan
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
| | - Guy Anna
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| | - Neil James Sebire
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
- Department of Histopathology, Great Ormond Street Hospital for Children, London, UK
| | - Owen John Arthurs
- Department of Clinical Radiology, Great Ormond Street Hospital for Children, London, UK
- Great Ormond Street Hospital for Children, UCL Great Ormond Street Institute of Child Health, London, UK
- NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK
| |
Collapse
|
10
|
Shelmerdine SC, Hutchinson JC, Lewis C, Simcock IC, Sekar T, Sebire NJ, Arthurs OJ. A pragmatic evidence-based approach to post-mortem perinatal imaging. Insights Imaging 2021; 12:101. [PMID: 34264420 PMCID: PMC8282801 DOI: 10.1186/s13244-021-01042-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 06/24/2021] [Indexed: 12/16/2022] Open
Abstract
Post-mortem imaging has a high acceptance rate amongst parents and healthcare professionals as a non-invasive method for investigating perinatal deaths. Previously viewed as a 'niche' subspecialty, it is becoming increasingly requested, with general radiologists now more frequently asked to oversee and advise on appropriate imaging protocols. Much of the current literature to date has focussed on diagnostic accuracy and clinical experiences of individual centres and their imaging techniques (e.g. post-mortem CT, MRI, ultrasound and micro-CT), and pragmatic, evidence-based guidance for how to approach such referrals in real-world practice is lacking. In this review, we summarise the latest research and provide an approach and flowchart to aid decision-making for perinatal post-mortem imaging. We highlight key aspects of the maternal and antenatal history that radiologists should consider when protocolling studies (e.g. antenatal imaging findings and history), and emphasise important factors that could impact the diagnostic quality of post-mortem imaging examinations (e.g. post-mortem weight and time interval). Considerations regarding when ancillary post-mortem image-guided biopsy tests are beneficial are also addressed, and we provide key references for imaging protocols for a variety of cross-sectional imaging modalities.
Collapse
Affiliation(s)
- Susan C Shelmerdine
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK. .,UCL Great Ormond Street Institute of Child Health, London, UK. .,Great Ormond Street Hospital NIHR Biomedical Research Centre, London, UK.
| | - J Ciaran Hutchinson
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK.,UCL Great Ormond Street Institute of Child Health, London, UK.,Great Ormond Street Hospital NIHR Biomedical Research Centre, London, UK
| | - Celine Lewis
- Population, Policy and Practice Department, UCL GOS Institute of Child Health, London, UK.,North Thames Genomic Laboratory Hub, Great Ormond Street Hospital, London, UK
| | - Ian C Simcock
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK.,UCL Great Ormond Street Institute of Child Health, London, UK.,Great Ormond Street Hospital NIHR Biomedical Research Centre, London, UK
| | - Thivya Sekar
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK.,UCL Great Ormond Street Institute of Child Health, London, UK.,Great Ormond Street Hospital NIHR Biomedical Research Centre, London, UK
| | - Neil J Sebire
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK.,UCL Great Ormond Street Institute of Child Health, London, UK.,Great Ormond Street Hospital NIHR Biomedical Research Centre, London, UK
| | - Owen J Arthurs
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK.,UCL Great Ormond Street Institute of Child Health, London, UK.,Great Ormond Street Hospital NIHR Biomedical Research Centre, London, UK
| |
Collapse
|
11
|
Shelmerdine SC, Sebire NJ, Arthurs OJ. Diagnostic accuracy of postmortem ultrasound vs postmortem 1.5-T MRI for non-invasive perinatal autopsy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 57:449-458. [PMID: 32149428 PMCID: PMC8432154 DOI: 10.1002/uog.22012] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/12/2019] [Accepted: 02/14/2020] [Indexed: 06/10/2023]
Abstract
OBJECTIVES To determine the diagnostic accuracy of postmortem magnetic resonance imaging (PM-MRI) and postmortem ultrasound (PM-US) for perinatal autopsy in the same patient cohort, and to determine whether PM-US can provide the same anatomical information as PM-MRI. METHODS In this prospective, 5-year (July 2014-July 2019) single-center study, we performed 1.5-T PM-MRI and PM-US in an unselected cohort of perinatal deaths. The diagnostic accuracies of both modalities were calculated, using autopsy as the reference standard. As a secondary objective, the concordance rates between the two imaging modalities for the overall main diagnosis and for five anatomical regions (brain, spine, thorax, heart and abdomen) were calculated. RESULTS During the study period, 136 cases underwent both PM-US and PM-MRI, of which 88 (64.7%) also underwent autopsy. There was no significant difference in the rates of concordance with autopsy between the two modalities for overall diagnosis (PM-US, 86.4% (95% CI, 77.7-92.0%) vs PM-MRI, 88.6% (95% CI, 80.3-93.7%)) or in the sensitivities and specificities for individual anatomical regions. There were more non-diagnostic PM-US than PM-MRI examinations for the brain (22.8% vs 3.7%) and heart (14.7% vs 5.1%). If an 'imaging-only' autopsy had been performed, PM-US would have achieved the same diagnosis as 1.5-T PM-MRI in 86.8% (95% CI, 80.0-91.5%) of cases, with the highest rates of agreement being for spine (99.3% (95% CI, 95.9-99.9%)) and cardiac (97.3% (95% CI, 92.4-99.1%)) findings and the lowest being for brain diagnoses (85.2% (95% CI, 76.9-90.8%)). CONCLUSION Although there were fewer non-diagnostic cases using PM-MRI than for PM-US, the high concordance rate for overall diagnosis suggests that PM-US could be used for triaging cases when PM-MRI access is limited or unavailable. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- S. C. Shelmerdine
- Department of Clinical RadiologyGreat Ormond Street Hospital for ChildrenLondonUK
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
| | - N. J. Sebire
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
- NIHR Great Ormond Street Hospital Biomedical Research CentreLondonUK
| | - O. J. Arthurs
- Department of Clinical RadiologyGreat Ormond Street Hospital for ChildrenLondonUK
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
- NIHR Great Ormond Street Hospital Biomedical Research CentreLondonUK
| |
Collapse
|
12
|
Kang X, Carlin A, Cannie MM, Sanchez TC, Jani JC. Fetal postmortem imaging: an overview of current techniques and future perspectives. Am J Obstet Gynecol 2020; 223:493-515. [PMID: 32376319 DOI: 10.1016/j.ajog.2020.04.034] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 04/19/2020] [Accepted: 04/28/2020] [Indexed: 12/19/2022]
Abstract
Fetal death because of miscarriage, unexpected intrauterine fetal demise, or termination of pregnancy is a traumatic event for any family. Despite advances in prenatal imaging and genetic diagnosis, conventional autopsy remains the gold standard because it can provide additional information not available during fetal life in up to 40% of cases and this by itself may change the recurrence risk and hence future counseling for parents. However, conventional autopsy is negatively affected by procedures involving long reporting times because the fetal brain is prone to the effect of autolysis, which may result in suboptimal examinations, particularly of the central nervous system. More importantly, fewer than 50%-60% of parents consent to invasive autopsy, mainly owing to the concerns about body disfigurement. Consequently, this has led to the development of noninvasive perinatal virtual autopsy using imaging techniques. Because a significant component of conventional autopsy involves the anatomic examination of organs, imaging techniques such as magnetic resonance imaging, ultrasound, and computed tomography are possible alternatives. With a parental acceptance rate of nearly 100%, imaging techniques as part of postmortem examination have become widely used in recent years in some countries. Postmortem magnetic resonance imaging using 1.5-Tesla magnets is the most studied technique and offers an overall diagnostic accuracy of 77%-94%. It is probably the best choice as a virtual autopsy technique for fetuses >20 weeks' gestation. However, for fetuses <20 weeks' gestation, its performance is poor. The use of higher magnetic resonance imaging magnetic fields such as 3-Tesla may slightly improve performance. Of note, in cases of fetal maceration, magnetic resonance imaging may offer diagnoses in a proportion of brain lesions wherein conventional autopsy fails. Postmortem ultrasound examination using a high-frequency probe offers overall sensitivity and specificity of 67%-77% and 74%-90%, respectively, with the advantage of easy access and affordability. The main difference between postmortem ultrasound and magnetic resonance imaging relates to their respective abilities to obtain images of sufficient quality for a confident diagnosis. The nondiagnostic rate using postmortem ultrasound ranges from 17% to 30%, depending on the organ examined, whereas the nondiagnostic rate using postmortem magnetic resonance imaging in most situations is far less than 10%. For fetuses ≤20 weeks' gestation, microfocus computed tomography achieves close to 100% agreement with autopsy and is likely to be the technique of the future in this subgroup. The lack of histology has always been listed as 1 limitation of all postmortem imaging techniques. Image-guided needle tissue biopsy coupled with any postmortem imaging can overcome this limitation. In addition to describing the diagnostic accuracy and limitations of each imaging technology, we propose a novel, stepwise diagnostic approach and describe the possible application of these techniques in clinical practice as an alternative or an adjunct or for triage to select cases that would specifically benefit from invasive examination, with the aim of reducing parental distress and pathologist workload. The widespread use of postmortem fetal imaging is inevitable, meaning that hurdles such as specialized training and dedicated financing must be overcome to improve access to these newer, well-validated techniques.
Collapse
Affiliation(s)
- Xin Kang
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Andrew Carlin
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Mieke M Cannie
- Radiology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium; Department of Radiology, UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Teresa Cos Sanchez
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Jacques C Jani
- Departments of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium.
| |
Collapse
|
13
|
Shelmerdine SC, Hutchinson JC, Ward L, Sekar T, Ashworth MT, Levine S, Sebire NJ, Arthurs OJ. Feasibility of INTACT (INcisionless TArgeted Core Tissue) biopsy procedure for perinatal autopsy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 55:667-675. [PMID: 31271478 PMCID: PMC7317589 DOI: 10.1002/uog.20387] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 06/18/2019] [Accepted: 06/21/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVES To determine the feasibility and tissue yield of a perinatal incisionless ultrasound-guided biopsy procedure, the INcisionless Targeted Core Tissue (INTACT) technique, in the context of minimally invasive autopsy. METHODS Cases of perinatal death in which the parents consented for minimally invasive autopsy underwent postmortem magnetic resonance imaging and an INTACT biopsy procedure, defined as needle biopsy of organs via the umbilical cord, performed under ultrasound guidance. In each case, three cores of tissue were obtained from seven target organs (both lungs, both kidneys, heart, spleen and liver). Biopsy success was predefined as an adequate volume of the intended target organ for pathological analysis, as judged by a pathologist blinded to the case and biopsy procedure. RESULTS Thirty fetuses underwent organ sampling. Mean gestational age was 30 weeks (range, 18-40 weeks) and mean delivery-to-biopsy interval was 12 days (range, 6-22 days). The overall biopsy success rate was 153/201 (76.1%) samples, with the success rates in individual organs being highest for the heart and lungs (93% and 91%, respectively) and lowest for the spleen (11%). Excluding splenic samples, the biopsy success rate was 150/173 (86.7%). Histological abnormalities were found in 4/201 (2%) samples, all of which occurred in the lungs and kidneys of a fetus with pulmonary hypoplasia and multicystic kidney disease. CONCLUSIONS Incisionless ultrasound-guided organ biopsy using the INTACT procedure is feasible, with an overall biopsy success rate of over 75%. This novel technique offers the ideal combination of an imaging-led autopsy with organ sampling for parents who decline the conventional invasive approach. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- S. C. Shelmerdine
- Department of Clinical RadiologyGreat Ormond Street Hospital for ChildrenLondonUK
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
| | - J. C. Hutchinson
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - L. Ward
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - T. Sekar
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - M. T. Ashworth
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - S. Levine
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - N. J. Sebire
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - O. J. Arthurs
- Department of Clinical RadiologyGreat Ormond Street Hospital for ChildrenLondonUK
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
| |
Collapse
|
14
|
Shelmerdine SC, Langan D, Mandalia U, Sebire NJ, Arthurs OJ. Maceration determines diagnostic yield of fetal and neonatal whole body post-mortem ultrasound. Prenat Diagn 2020; 40:232-243. [PMID: 31743482 PMCID: PMC7028035 DOI: 10.1002/pd.5615] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 11/07/2019] [Accepted: 11/08/2019] [Indexed: 01/23/2023]
Abstract
OBJECTIVES To determine factors in nondiagnostic fetal and neonatal post-mortem ultrasound (PMUS) examinations. METHODS All fetal and neonatal PMUS examinations were included over a 5-year study period (2014-2019). Nondiagnostic image quality by body parts (brain, spine, thorax, cardiac, and abdomen) was recorded and correlated with patient variables. Descriptive statistics and logistic regression analyses were performed to identify significant factors for nondiagnostic studies. RESULTS Two hundred sixty-five PMUS examinations were included, with median gestational age of 22 weeks (12-42 wk), post-mortem weight of 363 g (16-4033 g), and post-mortem interval of 8 days (0-39 d). Diagnostic imaging quality was achieved for 178/265 (67.2%) studies. It was high for abdominal (263/265, 99.2%), thoracic (264/265, 99.6%), and spine (265/265, 100%) but lower for brain (210/265, 79.2%) and cardiac imaging (213/265, 80.4%). Maceration was the best overall predictor for nondiagnostic imaging quality (P < .0001). Post-mortem fetal weight was positively associated with cardiac (P = .0133) and negatively associated with brain imaging quality (P = .0002). Post-mortem interval was not a significant predictor. CONCLUSIONS Fetal maceration was the best predictor for nondiagnostic PMUS, particularly for brain and heart. Fetuses with marked maceration and suspected cardiac or brain anomalies should be prioritised for post-mortem MRI.
Collapse
Affiliation(s)
- Susan Cheng Shelmerdine
- Department of Clinical RadiologyGreat Ormond Street Hospital for ChildrenLondonUK
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
| | - Dean Langan
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
| | - Uday Mandalia
- Department of Clinical RadiologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - Neil James Sebire
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
- Department of HistopathologyGreat Ormond Street Hospital for ChildrenLondonUK
| | - Owen John Arthurs
- Department of Clinical RadiologyGreat Ormond Street Hospital for ChildrenLondonUK
- UCL Great Ormond Street Institute of Child HealthGreat Ormond Street Hospital for ChildrenLondonUK
| |
Collapse
|
15
|
Shelmerdine SC, Hutchinson JC, Arthurs OJ, Sebire NJ. Latest developments in post-mortem foetal imaging. Prenat Diagn 2019; 40:28-37. [PMID: 31525275 DOI: 10.1002/pd.5562] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 08/29/2019] [Accepted: 09/07/2019] [Indexed: 12/11/2022]
Abstract
A sustained decline in parental consent rates for perinatal autopsies has driven the development of less-invasive methods for death investigation. A wide variety of imaging modalities have been developed for this purpose and include post-mortem whole body magnetic resonance imaging (MRI), ultrasound, computed tomography (CT) and micro-focus CT techniques. These are also vital for "minimally invasive" methods, which include potential for tissue sampling, such as image guidance for targeted biopsies and laparoscopic-assisted techniques. In this article, we address the range of imaging techniques currently in clinical practice and those under development. Significant advances in high-field MRI and micro-focus CT imaging show particular promise for smaller and earlier gestation foetuses. We also review how MRI biomarkers such as diffusion-weighted imaging and organ volumetric analysis may aid diagnosis and image interpretation in the absence of autopsy data. Three-dimensional printing and augmented reality may help make imaging findings more accessible to parents, colleagues and trainees.
Collapse
Affiliation(s)
- Susan C Shelmerdine
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| | - John C Hutchinson
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| | - Owen J Arthurs
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| | - Neil J Sebire
- Department of Radiology Great Ormond Street Hospital for Children NHS Foundation Trust London, London, UK.,UCL Great Ormond Street Institute of Child Health London, London, UK.,NIHR Great Ormond Street Hospital Biomedical Research Centre London, London, UK
| |
Collapse
|
16
|
Shelmerdine SC, Sebire NJ, Arthurs OJ. Perinatal post-mortem ultrasound (PMUS): radiological-pathological correlation. Insights Imaging 2019; 10:81. [PMID: 31432284 PMCID: PMC6702254 DOI: 10.1186/s13244-019-0762-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 06/18/2019] [Indexed: 12/16/2022] Open
Abstract
There has been an increasing demand and interest in post-mortem imaging techniques, either as an adjunct or replacement for the conventional invasive autopsy. Post-mortem ultrasound (PMUS) is easily accessible and more affordable than other cross-sectional imaging modalities and allows visualisation of normal anatomical structures of the brain, thorax and abdomen in perinatal cases. The lack of aeration of post-mortem foetal lungs provides a good sonographic window for assessment of the heart and normal pulmonary lobulation, in contrast to live neonates.In a previous article within this journal, we published a practical approach to conducting a comprehensive PMUS examination. This covered the basic principles behind why post-mortem imaging is performed, helpful techniques for obtaining optimal PMUS images, and the expected normal post-mortem changes seen in perinatal deaths. In this article, we build upon this by focusing on commonly encountered pathologies on PMUS and compare these to autopsy and other post-mortem imaging modalities.
Collapse
Affiliation(s)
- Susan C Shelmerdine
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK.
- UCL Great Ormond Street Institute of Child Health, London, UK.
| | - Neil J Sebire
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK
- UCL Great Ormond Street Institute of Child Health, London, UK
| | - Owen J Arthurs
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, WC1N 3JH, UK
- UCL Great Ormond Street Institute of Child Health, London, UK
| |
Collapse
|
17
|
Carlin A, Kadji C, Cannie MM, Resta S, Kang X, Jani JC. The use of magnetic resonance imaging in the prediction of birthweight. Prenat Diagn 2019; 40:125-135. [PMID: 31319434 DOI: 10.1002/pd.5530] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 06/05/2019] [Accepted: 07/08/2019] [Indexed: 01/11/2023]
Abstract
Extremes of fetal growth can increase adverse pregnancy outcomes, and this is equally applicable to single and multiple gestations. Traditionally, these cases have been identified using simple two-dimensional ultrasound which is quite limited by its low precision. Magnetic resonance imaging (MRI) has now been used for many years in obstetrics, mainly as an adjunct to ultrasound for congenital abnormalities and increasingly as part of the post-mortem examination. However, MRI can also be used to accurately assess fetal weight as first demonstrated by Baker et al in 1994, using body volumes rather than standard biometric measurements. This publication was followed by several others, all of which confirmed the superiority of MRI; however, despite this initial promise, the technique has never been successfully integrated into clinical practice. In this review, we provide an overview of the literature, detail the various techniques and formulas currently available, discuss the applicability to specific high-risk groups and present our vision for the future of MRI within clinical obstetrics.
Collapse
Affiliation(s)
- Andrew Carlin
- Department of Obstetrics and Gynaecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Caroline Kadji
- Department of Obstetrics and Gynaecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Mieke M Cannie
- Department of Radiology, University Hospital Brugmann, Brussels, Belgium.,Department of Radiology, UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Serena Resta
- Department of Obstetrics and Gynaecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Xin Kang
- Department of Obstetrics and Gynaecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Jacques C Jani
- Department of Obstetrics and Gynaecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
18
|
Kang X, Resta S, Cos Sanchez T, Carlin A, Bevilacqua E, Jani JC. Impact of the delay between fetal death and delivery on the success of postmortem ultrasound following termination of pregnancy. J Matern Fetal Neonatal Med 2019; 34:1613-1618. [PMID: 31291806 DOI: 10.1080/14767058.2019.1642868] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVE To evaluate the impact of the delay between fetal death and delivery on the nondiagnostic rates of post-mortem ultrasound (PM-US), following the termination of pregnancy (TOP). METHODS We reviewed 204 cases of fetal two-dimensional PM-US performed in our center as part of a post-mortem imaging research program, over the last 5 years. Informed consent was obtained from the parents for all cases. PM-US was performed and reported according to a prespecified template with operators blinded to the prenatal diagnosis. In order to calculate the precise delay between the fetal death and the delivery, we included 107 fetal TOP's ≥ 20 weeks of gestational age (GA), where feticide was performed using an injection of lidocaine 2% prior to induction of labor. Logistic regression analysis was conducted to analyze the impact of delay between fetal death and delivery (in hours), the GA at TOP (in weeks) and the method of feticide (intracardiac versus intraumbilical injection) on the PMUS nondiagnostic rates. RESULTS The delay between fetal death and delivery increased the nondiagnostic rate of PM-US for cerebral examinations (OR: 1.04, IC 95%: 1.01-1.08, p < .05). For PM-US cardiac examination, the delay did not influence the nondiagnostic rate. However, GA (OR: 1.25, IC 95%: 1.10-1.46, p < .01) and feticide with intracardiac injection (OR: 4.29, IC 95%: 1.68-12.02, p < .01) were associated with higher nondiagnostic rates. For noncardiac thoracic and abdominal examinations, none of the studied variables influenced the nondiagnostic rate. CONCLUSION The success rate of cerebral PM-US was influenced by the delay between fetal death and delivery, suggesting a possible advantage of performing the feticide closer to the delivery where the examination of the brain is planned. For cardiac abnormalities, feticide by intraumbilical, rather than intracardiac injection improves diagnostic rates of cardiac PM-US.
Collapse
Affiliation(s)
- Xin Kang
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Serena Resta
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Teresa Cos Sanchez
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Andrew Carlin
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Elisa Bevilacqua
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| | - Jacques C Jani
- Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|