1
|
Halaby RN, Bruce CG, Kolandaivelu A, Bhatia NK, Rogers T, Khan JM, Yildirim DK, Jaimes AE, O'Brien K, Babaliaros VC, Greenbaum AB, Lederman RJ. Ventricular Intramyocardial Navigation for Tachycardia Ablation Guided by Electrograms (VINTAGE): Deep Ablation in Inaccessible Targets. JACC Clin Electrophysiol 2024; 10:814-825. [PMID: 38811066 DOI: 10.1016/j.jacep.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 03/27/2024] [Accepted: 04/03/2024] [Indexed: 05/31/2024]
Abstract
BACKGROUND Deep intramural ventricular tachycardia substrate targets are difficult to access, map, and ablate from endocardial and epicardial surfaces, resulting in high recurrence rates. OBJECTIVES In this study, the authors introduce a novel approach called ventricular intramyocardial navigation for tachycardia ablation guided by electrograms (VINTAGE) to access and ablate anatomically challenging ventricular tachycardia from within the myocardium. METHODS Guidewire/microcatheter combinations were navigated deep throughout the extravascular myocardium, accessed directly from the right ventricle cavity, in Yorkshire swine (6 naive, 1 infarcted). Devices were steered to various intramyocardial targets including the left ventricle summit, guided by fluoroscopy, unipolar electrograms, and/or electroanatomic mapping. Radiofrequency ablations were performed to characterize ablation parameters and reproducibility. Intramyocardial saline irrigation began 1 minute before ablation and continued throughout. Lesions were analyzed on cardiac magnetic resonance and necropsy. RESULTS VINTAGE was feasible in all animals within naive and infarcted myocardium. Forty-three lesions were created, using various guidewires and power settings. Forty-one (95%) lesions were detected on cardiac magnetic resonance and 38 (88%) on necropsy; all undetected lesions resulted from intentionally subtherapeutic ablation energy (10 W). Larger-diameter guidewires yielded larger size lesions. Lesion volumes on necropsy were significantly larger at 20 W than 10 W (178 mm3 [Q1-Q3: 104-382 mm3] vs 49 mm3 [Q1-Q3: 35-93 mm3]; P = 0.02). Higher power (30 W) did not create larger lesions. Median impedance dropped with preablation irrigation by 12 Ω (Q1-Q3: 8-17 Ω), followed by a further 15-Ω (Q1-Q3: 11-19 Ω) drop during ablation. Intramyocardial navigation, ablation, and irrigation were not associated with any complications. CONCLUSIONS VINTAGE was safe and effective at creating intramural ablation lesions in targets traditionally considered inaccessible from the endocardium and epicardium, both naive and infarcted. Intramyocardial guidewire irrigation and ablation at 20 W creates reproducibly large intramural lesions.
Collapse
Affiliation(s)
- Rim N Halaby
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christopher G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA; Emory University Hospital, Atlanta, Georgia, USA
| | - Aravindan Kolandaivelu
- Division of Cardiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | | | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA; MedStar Washington Hospital Center, Washington, DC, USA
| | - Jaffar M Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA; St Francis Hospital, Roslyn, New York, USA
| | - D Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Andi E Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | | | | | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
| |
Collapse
|
2
|
Single-needle electroporation and interstitial electrochemotherapy: in vivo safety and efficacy evaluation of a new system. Eur Radiol 2019; 29:6300-6308. [DOI: 10.1007/s00330-019-06251-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 04/12/2019] [Accepted: 04/24/2019] [Indexed: 12/18/2022]
|
3
|
Illustrating the Impact of Uneven Saline Distribution on Thermal Lesion During Radiofrequency Ablation Using Computer Simulation for Smarter Healthcare Treatment Planning. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0354-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
4
|
Abstract
Radio frequency (RF) ablation is the latest and most promising treatment for nonsurgical cancer patients. This article will explain the history of how RF ablation was developed, moving us through the quest for larger ablations. It will take the reader step by step through the actual procedure; explain the different RF systems available; describe the physics of how RF ablation works and why it is preferred over other predecessors, such as cryoablation, microwave ablation, laser ablation, chemoablation, and ethanol ablation; and describe the pitfalls of each. It will also mention the reasons why ultrasonography is the most popular guidance method, while computed tomography is used for follow-up.
Collapse
|
5
|
Tiong LU, Field JBF, Maddern GJ. Bimodal electric tissue ablation (BETA) compared with the Cool-Tip RFA system. ANZ J Surg 2012; 82:269-74. [PMID: 22510186 DOI: 10.1111/j.1445-2197.2011.05990.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND Bimodal electric tissue ablation (BETA) incorporates the process of electrolysis into radiofrequency ablation (RFA) to increase the size of tissue ablation. This study investigated whether BETA could increase the efficacy of the Cool-Tip RF system (Covidien, Boulder, CO, USA) to produce larger ablations. It also investigated whether applying electrolysis only during the pretreatment phase (called electrochemical treatment (ECT)/RFA group) is as effective as BETA (where electrolysis was used during both the pretreatment and RFA phases). METHODS A Cool-Tip RF system (Covidien) was used to test three types of ablations (RFA, BETA, and ECT/RFA) in a pig liver model. In BETA, 9 V of direct current was provided for 10 min, after which the RF generator was started and both electrical circuits were allowed to run concurrently. In ECT/RFA, however, the direct current circuit was switched off after 10 min of pretreatment and only RFA was performed as described above. Ablation sizes were measured in three dimensions. RESULTS The size of ablations (transverse diameter A and B) produced by BETA and ECT/RFA was significantly larger compared with standard RFA (P < 0/001). BETA also created larger ablations compared with ECT/RFA (P < 0.001). CONCLUSION BETA could improve the efficacy of the Cool-Tip RF system (Covidien) to achieve larger ablations. The increased tissue hydration improved delivery of electrical energy to the tissues and delayed the process of desiccation, thus allowing the ablation process to continue for longer periods of time to produce larger ablations. BETA could be used to treat larger liver tumours more effectively than standard RFA.
Collapse
Affiliation(s)
- Leong Ung Tiong
- University of Adelaide Discipline of Surgery, The Queen Elizabeth Hospital, Adelaide, South Australia, Australia
| | | | | |
Collapse
|
6
|
Adeyanju OO, Al-Angari HM, Sahakian AV. The improvement of irreversible electroporation therapy using saline-irrigated electrodes: a theoretical study. Technol Cancer Res Treat 2012; 10:347-60. [PMID: 21728392 DOI: 10.7785/tcrt.2012.500212] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Irreversible electroporation (IRE) is a novel therapy used to ablate tumors with high-field electric pulses applied in short durations. It is important to reduce the generation of heat in IRE to avoid the harmful effects of thermal damage. The objective of this simulation study was to examine the effects of saline irrigation in the reduction of heat upon electrodes used in IRE treatment of hepatocellular carcinoma. We used a two dimensional Finite Element Model of a tumor in a liver with electrodes placed at the center of the tumor. We simulated a typical electroporation protocol with varying thicknesses and conductivities of the saline layer, and we observed the maximum temperature and the distribution of the electric field and temperature in the tissue. Our results showed that the maximum temperature in the tissue decreases with the use of saline, but the surface area of the tumor that could potentially be thermally damaged may increase with the thickness and conductivity of the saline. With the use of saline, one can achieve upwards of a 17% reduction of the maximum temperature at the electrodes. Also, the distribution of temperature and the electric field becomes more homogenous between the electrodes as the conductivity of the saline layer increases for all thicknesses of saline. We conclude that irrigating electrodes with saline may be an effective measure to enhance the efficacy of irreversible electroporation by reducing the maximum temperature at the electrodes and also improving the extent and distribution of the electric field in the tissue. However, the properties of the saline should be adjusted so as to limit the increase of thermal damage propagated in the tissue.
Collapse
Affiliation(s)
- Oyinlolu O Adeyanju
- Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, IL, USA.
| | | | | |
Collapse
|
7
|
Adam R, Hoti E, Bredt LC. Evolution of neoadjuvant therapy for extended hepatic metastases-have we reached our (non-resectable) limit? J Surg Oncol 2010; 102:922-31. [PMID: 21165994 DOI: 10.1002/jso.21727] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- René Adam
- AP-HP Hospital Paul Brousse, Centre Hépato-Biliaire, Villejuif, France.
| | | | | |
Collapse
|
8
|
Adam R, Hoti E, Bredt LC. Evolution of neoadjuvant therapy for extended hepatic metastases-have we reached our (non-resectable) limit? J Surg Oncol 2010. [DOI: https:/doi.org/10.1002/jso.21727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
9
|
|
10
|
Seinstra BA, van Delden OM, van Erpecum KJ, van Hillegersberg R, Mali WPTM, van den Bosch MAAJ. Minimally invasive image-guided therapy for inoperable hepatocellular carcinoma: What is the evidence today? Insights Imaging 2010; 1:167-81. [PMID: 23100194 PMCID: PMC3288853 DOI: 10.1007/s13244-010-0027-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2010] [Revised: 05/23/2010] [Accepted: 05/28/2010] [Indexed: 02/08/2023] Open
Abstract
Hepatocellular carcinoma (HCC) is a primary malignant tumor of the liver that accounts for an important health problem worldwide. Only 10-15% of HCC patients are suitable candidates for hepatic resection and liver transplantation due to the advanced stage of the disease at time of diagnosis and shortage of donors. Therefore, several minimally invasive image-guided therapies for locoregional treatment have been developed. Tumor ablative techniques are either based on thermal tumor destruction, as in radiofrequency ablation, cryoablation, microwave ablation, laser ablation and high-intensity focused ultrasound, or chemical tumor destruction, as in percutaneous ethanol injection. Image-guided catheter-based techniques rely on intra-arterial delivery of embolic, chemoembolic or radioembolic agents. These minimally invasive image-guided therapies have revolutionized the management of inoperable HCC. This review provides a description of all minimally invasive image-guided therapies currently available, an up-to-date overview of the scientific evidence for their clinical use, and thoughts for future directions.
Collapse
Affiliation(s)
- Beatrijs A. Seinstra
- Department of Radiology, University Medical Center Utrecht, Room E.01.132, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - Otto M. van Delden
- Department of Radiology, Academic Medical Center Amsterdam, Amsterdam, The Netherlands
| | - Karel J. van Erpecum
- Department of Gastroenterology, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Willem P. Th. M. Mali
- Department of Radiology, University Medical Center Utrecht, Room E.01.132, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - Maurice A. A. J. van den Bosch
- Department of Radiology, University Medical Center Utrecht, Room E.01.132, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| |
Collapse
|
11
|
Zurbuchen U, Holmer C, Lehmann KS, Stein T, Roggan A, Seifarth C, Buhr HJ, Ritz JP. Determination of the temperature-dependent electric conductivity of liver tissue ex vivo and in vivo: Importance for therapy planning for the radiofrequency ablation of liver tumours. Int J Hyperthermia 2010; 26:26-33. [DOI: 10.3109/02656730903436442] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
|
12
|
Nour SG, Goldberg SN, Wacker FK, Rafie S, Paul S, Heidenreich JO, Rodgers M, Abdul-Karim FW, Duerk JL, Lewin JS. MR monitoring of NaCl-enhanced radiofrequency ablations: observations on low- and high-field-strength MR images with pathologic correlation. Radiology 2010; 254:449-59. [PMID: 20089724 DOI: 10.1148/radiol.253180614] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To test the hypothesis that magnetic resonance (MR) imaging can be used to monitor both intraparenchymal injection of NaCl solution and subsequent radiofrequency ablation (RFA) within tissues pretreated with NaCl, report the low- and high-field-strength MR appearance of NaCl-enhanced RFAs, and compare MR findings with pathologic findings. MATERIALS AND METHODS Ten ex vivo calf liver specimens were injected with saturated NaCl (seven were mixed with methylene blue during MR fluoroscopic monitoring) and reexamined with fast imaging with steady-state progression (FISP), true FISP, reversed FISP (PSIF), and fast spin-echo T2-weighted MR sequences. The NaCl-to-liver contrast-to-noise ratio (CNR) was calculated for various sequences, and CNRs were compared with the Student t test. Distribution on MR images was compared with the results of pathologic analysis. Forty additional in vivo monopolar RFAs were performed in paraspinal muscles of seven minipigs after animal care committee approval (10 standard control ablations, 30 were preceded by direct injection of saturated NaCl at various volumes [3-9 mL] and rates [1 or 6mL/min]). Postablation low-field-strength (n = 20) and high-field-strength (n = 20) MR examinations consisted of T2-weighted imaging, short inversion time inversion-recovery (STIR) imaging, and contrast material-enhanced T1-weighted imaging. Ablation shape, conspicuity, volume, and signal intensity were compared between the two groups and with the results of pathologic analysis. The difference in volumes with and without NaCl injection was evaluated by using two-way analysis of variance. RESULTS Mean CNR was highest on fast spin-echo T2-weighted images and was significantly higher for PSIF than for FISP (P < .0001) or true FISP (P = .003). NaCl distribution on MR images corresponded with the results of pathologic analysis in ex vivo livers. Interactive in vivo monitoring of NaCl injection and electrode placement was feasible. NaCl-enhanced ablations had irregular shapes, a higher CNR, and significantly larger volumes (F = 22.0; df = 1, 90; P < .00001). All ablations had intermediate or low signal intensity with high-signal-intensity rims on all images. Fluid signals overlaid NaCl-enhanced ablations on fast spin-echo T2-weighted and STIR images, particularly on high-field-strength MR images. CONCLUSION MR imaging can be used to reliably monitor the distribution of injected NaCl solution in tissues. Interventional MR imaging techniques can be used to guide and monitor RFAs within NaCl pretreated tissues, with good correlation with pathologic results.
Collapse
Affiliation(s)
- Sherif Gamal Nour
- Department of Radiology, University Hospitals of Case Medical Center/Case Western Reserve University School of Medicine.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Linh PH, Thuan NC, Tuan NA, Thach PV, Yen TC, Quy NT, Nhung HTM, Xuyen PT, Phuc NX, Hong LV. Invitro toxicity test and searching the possibility of cancer cell line extermination by magnetic heating with using Fe3O4magnetic fluid. ACTA ACUST UNITED AC 2009. [DOI: 10.1088/1742-6596/187/1/012008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
14
|
Abstract
PURPOSE Evaluation of a new device designed to achieve large volumes of necrosis in hepatocellular carcinoma (HCC) nodules by application of radiofrequency ablation (RFA). MATERIALS AND METHODS 29 consecutive patients with 31 HCC nodules ≥3 cm in diameter (range 3-7.5 cm; mean diameter 5.5 cm) underwent ultrasound (US) guided percutaneous RFA using an expandable electrode with 7 active arrays and saline injection designed to create tissue ablation in areas of up to 7 cm (Starburst XLi-enhanced RFA device). Treatment was performed in general anesthesia (6 patients) or deep sedation (23 patients). Treatment efficacy was assessed by three-phase contrast-enhanced computed tomography (CT) and bimonthly US follow-up. RESULTS One to three electrode insertions (mean number 1.6) were performed in each patient. CT showed complete necrosis in 23/31 HCC nodules (74%) in 22 patients. Follow-up of these 22 patients ranged from 2 to 15 months (mean time 8.3 months). In 6/22 patients (28%) intrahepatic recurrence occurred within 5-10 months (mean time 8.3 months). Major complications were post-ablation syndrome in 7/29 (24%), peritoneal effusion in 4/29 (14%), pleural effusion in 2/29 (7%) and transient obstructive jaundice in 1/29 (3.4%) patients. One patient died 6 months after treatment because of tumor progression. CONCLUSIONS In the treatment of large HCC nodules, Starburst XLi-enhanced is an effective and safe device.
Collapse
|
15
|
Brook AL, Gold MM, Miller TS, Gold T, Owen RP, Sanchez LS, Farinhas JM, Shifteh K, Bello JA. CT-guided Radiofrequency Ablation in the Palliative Treatment of Recurrent Advanced Head and Neck Malignancies. J Vasc Interv Radiol 2008; 19:725-35. [DOI: 10.1016/j.jvir.2007.12.439] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2007] [Revised: 12/02/2007] [Accepted: 12/03/2007] [Indexed: 11/17/2022] Open
|
16
|
Lung Radiofrequency Ablation: In Vivo Experimental Study with Low-Perfusion-Rate Multitined Electrodes. Cardiovasc Intervent Radiol 2008; 31:610-8. [DOI: 10.1007/s00270-008-9306-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2007] [Revised: 12/29/2007] [Accepted: 01/09/2008] [Indexed: 11/26/2022]
|
17
|
Kim SK, Gu MS, Hong HP, Choi D, Chae SW. CT findings after radiofrequency ablation in rabbit livers: comparison of internally cooled electrodes, perfusion electrodes, and internally cooled perfusion electrodes. J Vasc Interv Radiol 2008; 18:1417-27. [PMID: 18003993 DOI: 10.1016/j.jvir.2007.08.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
PURPOSE To compare the computed tomography (CT) findings of radiofrequency (RF) ablation of rabbit livers with the use of internally cooled electrodes, perfusion electrodes, and internally cooled perfusion (ICP) electrodes. MATERIALS AND METHODS RF ablation zones were created in 24 rabbit livers in vivo in three groups, each treated at 30 W for 30 minutes with an electrode with a 1-cm active portion: one group was treated with an internally cooled electrode (group A), one with a perfusion electrode (group B), and one with an ICP electrode (group C). In the latter two groups, 0.9% saline solution mixed with contrast medium (9:1 ratio) was infused at a rate of 1 mL/min. Immediate CT images were ascertained in all groups and follow-up CT was performed in the latter two groups. CT findings of the RF ablation zone and surrounding liver parenchyma were evaluated and compared among groups. RESULTS On immediate unenhanced CT, infused contrast medium was noted in the center of the ablation zone without extravasation. Marginal linear or tubular low densities of the RF ablation zone were noted only in groups B (n=4) and C (n=3). Liver infarction was more frequently noted in groups B (n=5) and C (n=7) than in group A (n=3). Periportal tracking was noted more frequently in groups B (n=7) and C (n=8) than in group A (n=1). Pericaval or perihepatic tracking was noted only in groups B (n=3) and C (n=3). Extensive portal venous gas was noted in one animal in group C. CONCLUSIONS On CT, RF ablation with the perfusion or ICP electrode seemed to show more severe surrounding parenchymal changes than RF ablation with an internally cooled electrode.
Collapse
Affiliation(s)
- Seung Kwon Kim
- Deparment of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 180 Pyung-Dong, Jongro-Ku, Seoul 110-746, South Korea.
| | | | | | | | | |
Collapse
|
18
|
Mulier S, Ni Y, Jamart J, Michel L, Marchal G, Ruers T. Radiofrequency ablation versus resection for resectable colorectal liver metastases: time for a randomized trial? Ann Surg Oncol 2007; 15:144-57. [PMID: 17906898 DOI: 10.1245/s10434-007-9478-5] [Citation(s) in RCA: 114] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2007] [Accepted: 05/07/2007] [Indexed: 01/01/2023]
Abstract
BACKGROUND Surgical resection is the gold standard in the treatment of resectable colorectal liver metastases (CRLM). In several centers, resection is being replaced by radiofrequency ablation (RFA), even though there is no evidence yet from randomized trials to support this. The aim of this study was to critically review the oncological evidence for and against the use of RFA for resectable CRLM. METHODS An exhaustive review of RFA of colorectal metastases was carried out. RESULTS Five-year survival data after RFA for resectable CRLM are not available. Percutaneous RFA is associated with worse local control, worse staging, and a small risk of electrode track seeding when compared with resection (level V evidence). For tumors </=3 cm, local control after surgical RFA is equivalent to resection, especially if applied by experienced physicians to nonperivascular tumors (level V evidence). There is indirect evidence for profoundly different biological effects of RFA and resection. CONCLUSIONS A subgroup of patients has been identified for whom local control after RFA might be equivalent to resection. Whether this is true, and whether this translates into equivalent survival, remains to be proven. The time has come for a randomized trial.
Collapse
Affiliation(s)
- Stefaan Mulier
- Department of Surgery, Leopold Park Clinic, Froissartstraat 34, B-1040, Brussels, Belgium
| | | | | | | | | | | |
Collapse
|
19
|
Mulier S, Ni Y, Frich L, Burdio F, Denys AL, De Wispelaere JF, Dupas B, Habib N, Hoey M, Jansen MC, Lacrosse M, Leveillee R, Miao Y, Mulier P, Mutter D, Ng KK, Santambrogio R, Stippel D, Tamaki K, van Gulik TM, Marchal G, Michel L. Experimental and Clinical Radiofrequency Ablation: Proposal for Standardized Description of Coagulation Size and Geometry. Ann Surg Oncol 2007; 14:1381-96. [PMID: 17242989 DOI: 10.1245/s10434-006-9033-9] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2005] [Accepted: 04/03/2006] [Indexed: 12/22/2022]
Abstract
BACKGROUND Radiofrequency (RF) ablation is used to obtain local control of unresectable tumors in liver, kidney, prostate, and other organs. Accurate data on expected size and geometry of coagulation zones are essential for physicians to prevent collateral damage and local tumor recurrence. The aim of this study was to develop a standardized terminology to describe the size and geometry of these zones for experimental and clinical RF. METHODS In a first step, the essential geometric parameters to accurately describe the coagulation zones and the spatial relationship between the coagulation zones and the electrodes were defined. In a second step, standard terms were assigned to each parameter. RESULTS The proposed terms for single-electrode RF ablation include axial diameter, front margin, coagulation center, maximal and minimal radius, maximal and minimal transverse diameter, ellipticity index, and regularity index. In addition a subjective description of the general shape and regularity is recommended. CONCLUSIONS Adoption of the proposed standardized description method may help to fill in the many gaps in our current knowledge of the size and geometry of RF coagulation zones.
Collapse
Affiliation(s)
- Stefaan Mulier
- Department of Radiology, Gasthuisberg University Hospital, Herestraat 49, 3000 Leuven, Belgium
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Aubé C, Schmidt D, Brieger J, Schenk M, Kroeber S, Vielle B, Claussen CD, Goldberg SN, Pereira PL. Influence of NaCl Concentrations on Coagulation, Temperature, and Electrical Conductivity Using a Perfusion Radiofrequency Ablation System: An Ex Vivo Experimental Study. Cardiovasc Intervent Radiol 2006; 30:92-7. [PMID: 17103104 DOI: 10.1007/s00270-006-0091-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
PURPOSE To determine, by means of an ex vivo study, the effect of different NaCl concentrations on the extent of coagulation obtained during radiofrequency (RF) ablation performed using a digitally controlled perfusion device. METHOD Twenty-eight RF ablations were performed with 40 W for 10 min using continuous NaCl infusion in fresh excised bovine liver. For perfusion, NaCl concentrations ranging from 0 (demineralized water) to 25% were used. Temperature, the amount of energy, and the dimensions of thermal-induced white coagulation were assessed for each ablation. These parameters were compared using the nonparametric Mann-Whitney test. Correlations were calculated according to the Spearman test. RESULTS RF ablation performed with 0.9% to 25% concentrations of NaCl produced a mean volume of coagulation of 30.7 +/- 3.8 cm(3), with a mean short-axis diameter of 3.6 +/- 0.2 cm. The mean amount of energy was 21,895 +/- 1,674 W and the mean temperature was 85.4 +/- 12.8 degrees C. Volume of coagulation, short-axis diameter, and amount of energy did not differ significantly among NaCl concentrations (p > 0.5). A correlation was found between the NaCl concentration and the short-axis diameter of coagulation (r = 0.64) and between the NaCl concentration and the mean temperature (r = 0.67), but not between the NaCl concentration and volume of coagulation. CONCLUSION In an ex vivo model, continuous perfusion with high NaCl concentrations does not significantly improve the volume of thermal-induced coagulation. This may be because the use of a low-power generator cannot sufficiently exploit the potential advantage of better tissue conductivity provided by NaCl perfusion.
Collapse
Affiliation(s)
- Christophe Aubé
- Department of Diagnostic Radiology, Eberhard Karls University, Tübingen, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Hong K, Georgiades CS, Geschwind JFH. Technology insight: Image-guided therapies for hepatocellular carcinoma--intra-arterial and ablative techniques. ACTA ACUST UNITED AC 2006; 3:315-24. [PMID: 16757969 DOI: 10.1038/ncponc0512] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2005] [Accepted: 04/03/2006] [Indexed: 02/06/2023]
Abstract
Locoregional techniques have become the mainstay of therapy for patients with unresectable hepatocellular carcinoma (HCC). Such image-guided interventions include catheter-based approaches (transarterial chemoembolization and yttrium-90 radiotherapy) and locoregional ablative techniques, either chemical (percutaneous ethanol injection), or thermal (radiofrequency ablation, laser ablation, microwave ablation and cryoablation). These therapies are mainly utilized for palliation, but have also been used with curative intent. In selected cases, percutaneous interventional treatments have shown good results (5-year survival 40-50%), but, even when chosen as first-line treatment, have not been able to achieve the response rates and outcomes achieved by surgical options (resection or transplantation). New promising image-guided therapies are continuously emerging, as we attempt to improve tumor targeting, minimize hepatic toxicity and ultimately improve quality of life and survival of patients with HCC. With new technologies in imaging and drug delivery becoming available, it is likely that, in the future, patients with HCC will be best treated by a multidisciplinary team approach, utilizing a combination of techniques to improve patient survival. This review outlines the current status of the most commonly used image-guided locoregional interventions in the treatment of patients with HCC, and describes recent research and advances related to image-guided interventions for liver cancer.
Collapse
Affiliation(s)
- Kelvin Hong
- Division of Interventional Radiology, Johns Hopkins School of Medicine, Baltimore, MD 21287, USA.
| | | | | |
Collapse
|
22
|
Lee JM, Han JK, Kim SH, Shin KS, Lee JY, Park HS, Hur H, Choi BI. Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection: ex vivo bovine liver. Korean J Radiol 2006; 5:258-65. [PMID: 15637476 PMCID: PMC2698170 DOI: 10.3348/kjr.2004.5.4.258] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
OBJECTIVE We wished to compare the in-vitro efficiency of wet radiofrequency(RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver. MATERIALS AND METHODS Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups. RESULTS With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 ohm) than for group A (80 ohm) (p < 0.05). During RF ablation, the tissue impedance was well controlled in groups C and E, but it was often rapidly increased to more than 200 ohm in groups A and B. In group D, the impedance was well controlled in six of ten trials but it was increased in four trials (40%) 7 min after starting RF ablation. As consequences, the mean current was higher for groups C, D, and E than for the other groups: 401+/-145 mA in group A, 287+/-32 mA in group B, 1907+/-96 mA in group C, 1649+/-514 mA in group D, and 1968+/-108 mA in group E (p< 0.05). In addition, the volumes of RF-induced coagulation necrosis were greater in groups C and E than in group D, which was greater than in groups A and B than in group E (p < 0.05); 14.3+/-3.0 cm(3) in group A; 12.4+/-3.8 cm(3) in group B; 80.9+/-9.9 cm(3) in group C; 45.3+/-11.3 cm(3) in group D and 81.6+/-8.6 cm(3) in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (p < 0.05): 53+/-12 degrees C in group A, 42+/-2 degrees C in group B, 93+/-8 degrees C in group C; 79+/-12 degrees C in group D and 83+/-8 degrees C in group E. CONCLUSION Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with preinjection of NaCl solutions.
Collapse
Affiliation(s)
- Jeong Min Lee
- Department of Radiology, and Institute of Radiation Medicine, Seoul National University College of Medicine, Korea
- Clinical Research Institute, Seoul National University Hospital, Korea
| | - Joon Koo Han
- Department of Radiology, and Institute of Radiation Medicine, Seoul National University College of Medicine, Korea
- Clinical Research Institute, Seoul National University Hospital, Korea
| | - Se Hyung Kim
- Department of Radiology, and Institute of Radiation Medicine, Seoul National University College of Medicine, Korea
- Clinical Research Institute, Seoul National University Hospital, Korea
| | - Kyung Sook Shin
- Department of Radiology, Chungnam National University College of Medicine, Korea
| | - Jae Young Lee
- Department of Radiology, and Institute of Radiation Medicine, Seoul National University College of Medicine, Korea
- Clinical Research Institute, Seoul National University Hospital, Korea
| | - Hee Sun Park
- Department of Radiology, and Institute of Radiation Medicine, Seoul National University College of Medicine, Korea
- Clinical Research Institute, Seoul National University Hospital, Korea
| | - Hurn Hur
- Department of Radiology, and Institute of Radiation Medicine, Seoul National University College of Medicine, Korea
- Clinical Research Institute, Seoul National University Hospital, Korea
| | - Byung Ihn Choi
- Department of Radiology, and Institute of Radiation Medicine, Seoul National University College of Medicine, Korea
- Clinical Research Institute, Seoul National University Hospital, Korea
| |
Collapse
|
23
|
Ritz JP, Lehmann KS, Reissfelder C, Albrecht T, Frericks B, Zurbuchen U, Buhr HJ. Bipolar radiofrequency ablation of liver metastases during laparotomy. First clinical experiences with a new multipolar ablation concept. Int J Colorectal Dis 2006; 21:25-32. [PMID: 15875202 DOI: 10.1007/s00384-005-0781-y] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/21/2005] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND OBJECTIVE Radiofrequency ablation (RFA) is a promising method for local treatment of liver malignancies. Currently available systems for radiofrequency ablation use monopolar current, which carries the risk of uncontrolled electrical current paths, collateral damages and limited effectiveness. To overcome this problem, we used a newly developed internally cooled bipolar application system in patients with irresectable liver metastases undergoing laparotomy. The aim of this study was to clinically evaluate the safety, feasibility and effectiveness of this new system with a novel multipolar application concept. PATIENTS AND METHODS Patients with a maximum of five liver metastases having a maximum diameter of 5 cm underwent laparotomy and abdominal exploration to control resectability. In cases of irresectability, RFA with the newly developed bipolar application system was performed. Treatment was carried out under ultrasound guidance. Depending on tumour size, shape and location, up to three applicators were simultaneously inserted in or closely around the tumour, never exceeding a maximum probe distance of 3 cm. In the multipolar ablation concept, the current runs alternating between all possible pairs of consecutively activated electrodes with up to 15 possible electrode combinations. Post-operative follow-up was evaluated by CT or MRI controls 24-48 h after RFA and every 3 months. RESULTS In a total of six patients (four male, two female; 61-68 years), ten metastases (1.0-5.5 cm) were treated with a total of 14 RF applications. In four metastases three probes were used, and in another four and two metastases, two and one probes were used, respectively. During a mean ablation time of 18.8 min (10-31), a mean energy of 48.8 kJ (12-116) for each metastases was applied. No procedure-related complications occurred. The patients were released from the hospital between 7 and 12 days post-intervention (median 9 days). The post-interventional control showed complete tumour ablation in all cases. CONCLUSIONS Bipolar radiofrequency using the novel multipolar ablation concept permits a safe and effective therapy for the induction of large volumes of coagulation in the local treatment of liver metastases.
Collapse
Affiliation(s)
- Joerg-Peter Ritz
- Department of General, Vascular and Thoracic Surgery, Charité, University Medicine Berlin, Campus Benjamin Franklin, Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
24
|
Ritz JP, Lehmann KS, Isbert C, Reissfelder C, Albrecht T, Stein T, Buhr HJ. In-vivo evaluation of a novel bipolar radiofrequency device for interstitial thermotherapy of liver tumors during normal and interrupted hepatic perfusion. J Surg Res 2005; 133:176-84. [PMID: 16360176 DOI: 10.1016/j.jss.2005.09.028] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2005] [Revised: 09/28/2005] [Accepted: 09/28/2005] [Indexed: 02/07/2023]
Abstract
BACKGROUND Only monopolar systems have thus far been available for radiofrequency ablation of liver tumors, whose application is restricted because of the incalculable energy flow, reduction of electrical tissue conduction, and limited lesion size. The aim of this study was to evaluate a novel internally cooled bipolar radiofrequency application device under in vivo conditions and to compare the effect of this system on lesion size when combined with hepatic arterial microembolization or complete hepatic blood flow occlusion. MATERIALS AND METHODS In a porcine liver model, RFA (60 W, 12 min) was performed with either normal (n = 12), partially interrupted (arterial microembolization via a hepatic artery catheter n = 12) or completely interrupted hepatic perfusion (Pringle's maneuver, n = 12). RFA parameters (impedance, power output, temperature, applied energy) were determined continuously during therapy. RFA lesions were macroscopically assessed after liver dissection. RESULTS Bipolar RFA induced clinical relevant ellipsoid thermal lesions without complications. Hepatic inflow occlusion led to a 4.3-fold increase in lesion volume after arterial microembolization and a 5.8-fold increase after complete interruption (7.4 cm(3)versus 31.9 cm(3)versus 42.6 cm(3), P < 0.01). CONCLUSIONS The novel bipolar RFA device is a safe and effective alternative to monopolar RFA-systems. Interrupting hepatic perfusion significantly increases lesion volumes in bipolar RFA. This beneficial effect can also be achieved in the percutaneous application mode by RFA combined with arterial microembolization via a hepatic artery catheter.
Collapse
Affiliation(s)
- Joerg-P Ritz
- Department of General, Vascular and Thoracic Surgery, University Medicine Berlin, Campus Benjamin Franklin, Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
25
|
Ni Y, Mulier S, Miao Y, Michel L, Marchal G. A review of the general aspects of radiofrequency ablation. ACTA ACUST UNITED AC 2005; 30:381-400. [PMID: 15776302 DOI: 10.1007/s00261-004-0253-9] [Citation(s) in RCA: 134] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
As an alternative to standard surgical resection for the treatment of malignant tumors, radiofrequency ablation (RFA) has rapidly evolved into the most popular minimally invasive therapy. To help readers gain the relevant background knowledge and to better understand the other reviews in this Feature Section on the clinical applications of RFA in different abdominal organs, the present report covers the general aspects of RFA. After an introduction, we present a simple definition of the energy applied during RFA, a brief historical review of its technical evolution, and an explanation of the mechanism of action of RFA. These basic discussions are substantiated with descriptions of RFA equipment including those commercially available and those under preclinical development. The size and geometry of induced lesions in relation to RFA efficacy and side effects are discussed. The unique pathophysiologic process of thermal tissue damage and the corresponding histomorphologic manifestations after RFA are detailed and cross-referenced with the findings in the current literature. The crucial role of imaging technology during and after RFA is also addressed, including some promising new developments. This report finishes with a summary of the key messages and a perspective on further technologic refinements and identifies some specific priorities.
Collapse
Affiliation(s)
- Y Ni
- Department of Radiology, University Hospital Gasthuisberg, Catholic University of Leuven, Herestraat 49, B-3000 Leuven, Belgium.
| | | | | | | | | |
Collapse
|
26
|
Kim SK, Seo JW. Radiofrequency Ablation with a New Perfused-Cooled Electrode Using a Single Pump: An Experimental Study in Ex Vivo Bovine Liver. Cardiovasc Intervent Radiol 2005; 28:779-88. [PMID: 16187149 DOI: 10.1007/s00270-005-0047-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The purpose of this study was to assess the efficacy of a new perfused-cooled electrode that uses a single pump for creating a large ablation zone in explanted bovine liver. This was done by comparing with the radiofrequency (RF) ablation zones that were created with a monopolar cooled electrode to the RF ablation zones that were created by the new perfused-cooled electrode. We developed a new perfused-cooled electrode that uses a single pump by modifying a 17-gauge cooled electrode (Radionics) with a 2.5-cm outer metallic sheath (15-gauge) in order to allow use of the internal cooling water (5.85 % hypertonic saline) for the infused saline. Thirty ablation zones were created in explanted bovine livers (12-min ablation cycle; pulsed technique; 2000 mA, maximum) with three different regimens: group A, RF ablation with the 17-gauge cooled electrode; group B, RF ablation with the 15-gauge cooled electrode; group C, RF ablation with the perfused-cooled electrode. T2-weighted magnetic resonance (MR) imaging was obtained immediately after RF ablation for calculating volumes of the ablation zone. Following MR imaging, the ablation zones were excised and measured for transverse diameters and vertical diameters. The transverse diameter, vertical diameter, and the calculated volumes of the ablation zones on MR imaging were compared among the groups. Ablation zones created with the perfused-cooled electrode (group C) were significantly larger than those created with the 17-gauge cooled electrode (group A) and the 15-gauge cooled electrode (group B) according to the transverse diameter and vertical diameter on the gross specimens (p < 0.05): 3.6 +/- 0.38 cm and 4.4 +/- 0.20 cm in group A, 3.7 +/- 0.08 cm and 4.6 +/- 0.16 cm in group B, and 5.4 +/- 0.65 cm and 6.0 +/- 0.56 cm in group C, respectively. On the MR imaging, the calculated volumes of the ablation zones in group C were significantly larger than those in groups A and B (p < 0.05): 23.1 +/- 8.7 cm3 in group A, 28.9 +/- 5.7 cm3 in group B, and 80.0 +/- 34 cm3 in group C, respectively. A new perfused-cooled electrode using a single pump could efficiently increase the size of the ablation zone in liver compared with a monopolar cooled electrode, and this was due to its simultaneous use of internal cooling and saline infusion.
Collapse
Affiliation(s)
- Seung Kwon Kim
- Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
| | | |
Collapse
|
27
|
Abstract
Several different technologies have been employed for the local ablation of tissue by thermal techniques. At the present time the most widely favoured technique is radiofrequency ablation (RFA) but developments in other techniques, e.g. microwave may change this. In many countries RFA or percutaneous ethanol injection (PEI) are accepted therapies for patients with Childs Pugh Class A or B cirrhosis and early hepatocellular carcinoma (HCC). Results for RFA in large series of patients with liver metastases from colon cancer are very promising. Five-year survival rates of 26% from the time of first ablation and 30% from the diagnosis of liver metastases for patients with limited (<6, <5 cm) liver disease who are not surgical candidates compares well with post resection series where 5-year survival rates vary between 29% and 39% in operable candidates. Sufficient experience has now been gained in lung and renal ablation to show that these are minimally invasive techniques which can produce effective tumour destruction with a limited morbidity. More novel areas for ablation such as adrenal or pelvic recurrence are being explored.
Collapse
Affiliation(s)
- A R Gillams
- Department of Medical Imaging, The Middlesex Hospital, Mortimer Street, London, W1T 3AA, UK.
| |
Collapse
|
28
|
Nour SG. MRI-guided and monitored radiofrequency tumor ablation. Acad Radiol 2005; 12:1110-20. [PMID: 16099688 DOI: 10.1016/j.acra.2005.05.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2004] [Revised: 05/12/2005] [Accepted: 12/23/2004] [Indexed: 11/29/2022]
Affiliation(s)
- Sherif Gamal Nour
- Department of Radiology, University Hospitals of Cleveland/Case Western Reserve University School of Medicine, 11100 Euclid Avenue, Cleveland, OH 44106, USA.
| |
Collapse
|
29
|
Mulier S, Ni Y, Jamart J, Ruers T, Marchal G, Michel L. Local recurrence after hepatic radiofrequency coagulation: multivariate meta-analysis and review of contributing factors. Ann Surg 2005; 242:158-71. [PMID: 16041205 PMCID: PMC1357720 DOI: 10.1097/01.sla.0000171032.99149.fe] [Citation(s) in RCA: 523] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE The purpose of this study was to analyze the factors that influence local recurrence after radiofrequency coagulation of liver tumors. SUMMARY BACKGROUND DATA Local recurrence rate varies widely between 2% and 60%. Apart from tumor size as an important risk factor for local recurrence, little is known about the impact of other factors. METHODS An exhaustive literature search was carried out for the period from January 1, 1990 to January 1, 2004. Only series with a minimal follow-up of 6 months and/or mean follow-up of 12 months were included. Univariate and multivariate meta-analyses were carried out. RESULTS Ninety-five independent series were included, allowing the analysis of the local recurrence rate of 5224 treated liver tumors. In a univariate analysis, tumor-dependent factors with significantly less local recurrences were: smaller size, neuroendocrine metastases, nonsubcapsular location, and location away from large vessels. Physician-dependent favorable factors were: surgical (open or laparoscopic) approach, vascular occlusion, general anesthesia, a 1-cm intentional margin, and a greater physician experience. In a multivariate analysis, significantly less local recurrences were observed for small size (P < 0.001) and a surgical (versus percutaneous) approach (P < 0.001). CONCLUSIONS Radiofrequency coagulation by laparoscopy or laparotomy results in superior local control, independent of tumor size. The percutaneous route should mainly be reserved for patients who cannot tolerate a laparoscopy or laparotomy. The short-term benefits of less invasiveness for the percutaneous route do not outweigh the longer-term higher risk of local recurrence.
Collapse
Affiliation(s)
- Stefaan Mulier
- Department of Surgery, University Hospital of Mont-Godinne, Catholic University of Louvain, Yvoir, Belgium
| | | | | | | | | | | |
Collapse
|
30
|
Nour SG, Lewin JS. Radiofrequency Thermal Ablation: The Role of MR Imaging in Guiding and Monitoring Tumor Therapy. Magn Reson Imaging Clin N Am 2005; 13:561-81. [PMID: 16084420 DOI: 10.1016/j.mric.2005.04.007] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Performing RFA procedures under MR imaging involves two distinct processes: interactive guidance of the RF electrode into the targeted tumor and monitoring the effect of therapy. The justification for using MR imaging for electrode guidance is quite similar to its use to guide biopsy and aspiration procedures, where MR imaging offers advantages related to superior soft tissue contrast, multiplanar capabilities, and high vascular conspicuity that facilitate safe and accurate guidance in selected lesions. The major contribution of MR imaging to thermal ablation procedures is its ability to monitor tissue changes associated with the heating process instantaneously, an attribute that is not paralleled by any other currently available imaging modality. Such ability facilitates a controlled approach to ablation by helping to detect inadequately treated tumor foci for subsequent interactive repositioning of the RF electrode during therapy. As such, MR imaging guidance and monitoring enable treatment of the entire tumor on a single-visit basis while avoiding undue overtreatment and preserving often critically needed organ function. Although knowledge of interventional MR imaging concepts and familiarity with its technology and with the related safety issues are indispensable for interventional radiologists attempting thermal ablation procedures in the MR imaging environment, understanding the tissue basis of necrosis imaging is becoming an essential part of the knowledge base for the larger sector of general radiologists who are required to interpret the follow-up MR imaging scans of the increasing number of thermal ablation patients.
Collapse
Affiliation(s)
- Sherif Gamal Nour
- Department of Radiology, University Hospitals of Cleveland, 11100 Euclid Avenue, Cleveland, OH 44106, USA.
| | | |
Collapse
|
31
|
Jansen MC, van Hillegersberg R, Chamuleau RAFM, van Delden OM, Gouma DJ, van Gulik TM. Outcome of regional and local ablative therapies for hepatocellular carcinoma: a collective review. Eur J Surg Oncol 2005; 31:331-47. [PMID: 15837037 DOI: 10.1016/j.ejso.2004.10.011] [Citation(s) in RCA: 107] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2004] [Revised: 09/14/2004] [Accepted: 10/01/2004] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Transcatheter arterial (chemo) embolization (TACE), cryoablation (CA) and percutaneous ethanol injection (PEI) were the first regional and local ablative techniques that came into use for irresectable HCC. Radiofrequency ablation (RFA) and interstitial laser coagulation (ILC) followed and have now evolved rapidly. It would not be ethical to compare resection with ablation in patients well enough to undergo major surgery. Therefore, hepatic resection and hepatic transplantation remain the only curative treatment options for HCC. METHODS On the basis of a Medline literature search and the authors' experiences, the principles, current status and prospects of TACE and local ablative techniques in HCC are reviewed. RESULTS Complete tumour necrosis can be achieved in 60-100% of patients treated with PEI (70-100%), cryoablation (60-85%), RFA (80-90%) or ILC (70-97%). After TACE significant tumour response is achieved in 17-61.9% but complete tumour response is rare (0-4.8%) as viable tumour cells remain after TACE. Five-year survival rates are available for TACE (1-8%), PEI (0-70%) and cryoablation (40%). Only PEI and RFA were compared in one RCT. RFA was associated with fewer treatment sessions and a higher complete necrosis rate. Furthermore, all techniques are associated with low morbidity and mortality, but cryoablation seems to be associated with a higher morbidity rate. CONCLUSION TACE has shown to be a valuable therapy with survival benefits in strictly selected patients with unresectable HCC. RFA and PEI are now considered as the local ablative techniques of choice for the treatment of, preferably small, HCC. When tumours are located close to bile ducts or large vessels, PEI remains a valuable therapy. Completeness of ablation can be more easily monitored during cryoablation and another advantage of cryoablation is the possibility of edge freezing. The results of ILC are comparable to RFA with only few side effects and high tumour response rates.
Collapse
Affiliation(s)
- M C Jansen
- Department of Surgery, Academic Medical Center, Meibergdreef 9, P.O. Box 22660, 1105 AZ Amsterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|
32
|
Affiliation(s)
- A R Gillams
- Department of Medical Imaging, The Middlesex Hospital, Mortimer Street, London W1T 3AA, UK
| |
Collapse
|
33
|
Chang IA, Nguyen UD. Thermal modeling of lesion growth with radiofrequency ablation devices. Biomed Eng Online 2004; 3:27. [PMID: 15298708 PMCID: PMC514567 DOI: 10.1186/1475-925x-3-27] [Citation(s) in RCA: 170] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2004] [Accepted: 08/06/2004] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND Temperature is a frequently used parameter to describe the predicted size of lesions computed by computational models. In many cases, however, temperature correlates poorly with lesion size. Although many studies have been conducted to characterize the relationship between time-temperature exposure of tissue heating to cell damage, to date these relationships have not been employed in a finite element model. METHODS We present an axisymmetric two-dimensional finite element model that calculates cell damage in tissues and compare lesion sizes using common tissue damage and iso-temperature contour definitions. The model accounts for both temperature-dependent changes in the electrical conductivity of tissue as well as tissue damage-dependent changes in local tissue perfusion. The data is validated using excised porcine liver tissues. RESULTS The data demonstrate the size of thermal lesions is grossly overestimated when calculated using traditional temperature isocontours of 42 degrees C and 47 degrees C. The computational model results predicted lesion dimensions that were within 5% of the experimental measurements. CONCLUSION When modeling radiofrequency ablation problems, temperature isotherms may not be representative of actual tissue damage patterns.
Collapse
Affiliation(s)
- Isaac A Chang
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Rockville, Maryland, USA
| | - Uyen D Nguyen
- Department of Biomedical Engineering, Catholic University of America, Washington DC, USA
| |
Collapse
|
34
|
Finch JG, Fosh BG, Anthony AA, Texler M, Pearson S, Dennison AR, Maddern GJ. The use of a “Liquid” electrode in hepatic electrolysis. J Surg Res 2004; 120:272-7. [PMID: 15234223 DOI: 10.1016/j.jss.2004.03.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2003] [Indexed: 10/26/2022]
Abstract
BACKGROUND The use of direct current electrolysis as a local nonthermal ablative technique for colorectal liver metastases promises to be a simple, safe, and effective therapy. Under general anesthesia, electrolysis is presently limited to tumors smaller than 5 cm, due to the protracted nature of its administration. In an attempt to enhance the effect of electrolysis, a direct current was passed through a preinjected bolus of acetic acid. METHODS The effect of a combination of electrolysis and an injection of acetic acid was tested in the liver of eight normal pigs. The volumes of necrosis caused were analyzed. RESULTS Acetic acid independently produced a volume of necrosis but did not provide a volumetric or rate advantage when used in combination with a direct current. Statistically, the only main effect on the volume of necrosis was a result of electrolysis. CONCLUSION The use of 50% acetic acid to augment the efficacy of direct current electrolysis cannot be recommended.
Collapse
Affiliation(s)
- J Guy Finch
- Department of Surgery, University of Adelaide, The Queen Elizabeth Hospital, Woodville, South Australia 5011, Australia
| | | | | | | | | | | | | |
Collapse
|
35
|
Lee JM, Han JK, Kim SH, Sohn KL, Choi SH, Choi BI. Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system. Eur Radiol 2004; 15:759-64. [PMID: 15248081 DOI: 10.1007/s00330-004-2375-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2004] [Revised: 04/28/2004] [Accepted: 05/10/2004] [Indexed: 01/15/2023]
Abstract
The aim of this study was to investigate the efficacy of bipolar radiofrequency ablation (RFA) with the open-perfused electrode and cooled-wet electrode. Bipolar RF was applied for 20 min to the ex vivo bovine liver using either the Berchtold system with two 16-gauge open-perfused electrodes (group A, n=15) or the Radionics system with two 15-gauge cooled-wet electrodes (group B, n=15). In both groups, two electrodes were placed 3 cm apart. The ablation zone was created by the RF energy delivered together with the infusion of 5% hypertonic saline (2 ml/min). The dimension of the ablation zone, its shape and the changes in the impedance and W s of two groups during the RFA were examined and documented. The vertical diameter (Dv) along the probe, the long-axis diameter (Dl) perpendicular to the Dv in the longitudinal plane and the short-axis diameter of the ablation zone (Ds) in the transverse plane through the midpoint between the tips of two probes were measured. The mean accumulated energy output in the Radionics system was higher than in the Berchtold system (159,887.0+/-36,423 W s vs. 87,555.1+/-86,787 W s). The difference was statistically significant (P<0.05). In group A, the impedance intermittently rose to above 700 Omega during the RFA in all sessions, which led to a gradual decrease of the power output to lower than 30 W. In group B, on the other hand, the impedance did not change markedly. The mean Dv value of the coagulation necrosis in group B was significantly longer than in group A (5.0+/-0.4 cm vs. 4.3+/-0.6 cm, P<0.05). The mean Dl and Ds were 6.7+/-0.5 cm and 5.0+/-0.8 cm in group A, and 6.5+/-0.8 cm and 5.5+/-0.7 cm in group B, respectively (P>0.05). The data demonstrate that the cooled-wet electrode generates the more spherical ablation zone than the open-perfused electrode. With approximately doubled power output, the bipolar RFA with the cooled-wet electrodes induces a larger volume of tissue coagulation than with the open-perfused electrodes.
Collapse
Affiliation(s)
- Jeong Min Lee
- Department of Diagnostic Radiology, Clinical Research Institute, Seoul National University Hospital, 28 Yongon-dong, Chongno-gu, Seoul, 110-744, South Korea.
| | | | | | | | | | | |
Collapse
|
36
|
N/A. N/A. Shijie Huaren Xiaohua Zazhi 2004; 12:501-503. [DOI: 10.11569/wcjd.v12.i2.501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
37
|
Mulier S, Ni Y, Miao Y, Rosière A, Khoury A, Marchal G, Michel L. Size and geometry of hepatic radiofrequency lesions. Eur J Surg Oncol 2004; 29:867-78. [PMID: 14624780 DOI: 10.1016/j.ejso.2003.09.012] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
AIM To report and compare the size and geometry of hepatic radiofrequency (RF) lesions using the currently available commercial devices. METHODS A literature search was carried out for the period from January 1st 1990 to June 15th 2003. The commercial suppliers were asked to provide all available data. For each electrode and protocol, size and geometry of single-cycle thermal lesions were registered. RESULTS No information at all on size and geometry of the inducible lesions was available for 17 of the 28 current commercial electrodes. Many descriptions of RF lesions are limited to the mean transverse diameter. With normal blood flow, diameter of lesions is often smaller than suggested by the length of the electrode tip or the diameter of the deployed prongs. Lesions are rarely perfect spheres but either ellipses or flattened spheres. Distortion of the RF lesion by nearby blood vessels is very common. Fusion of thermal zones between prongs of expandable electrodes can be incomplete. Blood flow interruption using a Pringle maneuver yields larger lesions that are less distorted and more complete. CONCLUSIONS There is insufficient experimental data for many electrodes that are currently used in patients. RF companies should provide these data before releasing electrodes for use. For those electrodes for which data exist, coagulation lesions are often smaller, less spherical, less complete and less regular than generally presumed. Accurate knowledge of size and geometry of RF lesions is crucial to prevent local recurrence.
Collapse
Affiliation(s)
- S Mulier
- Department of Surgery, University Hospital of Mont-Godinne, Catholic University of Louvain, Yvoir, Belgium.
| | | | | | | | | | | | | |
Collapse
|
38
|
Lobo SM, Afzal KS, Ahmed M, Kruskal JB, Lenkinski RE, Goldberg SN. Radiofrequency Ablation: Modeling the Enhanced Temperature Response to Adjuvant NaCl Pretreatment. Radiology 2004; 230:175-82. [PMID: 14695392 DOI: 10.1148/radiol.2301021512] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To characterize the effects of volume and concentration of adjuvant NaCl pretreatment on radiofrequency (RF) ablation and to model these results to determine their applicability to in vivo systems. MATERIALS AND METHODS Standardized 1-L 5% agar phantoms were constructed with central wells of varying volume that were filled with a protein-based polymer gel of varying NaCl concentration (0%-35%). RF ablation to the maximum system current output (2000 mA) was applied to internally cooled 2-cm electrodes placed in the center of the gel wells. Remote thermometry was performed 20 mm from the electrode. Temperatures generated within the phantom were then used to model the response surface by using regression analysis. The generated model was then applied to previously published in vivo data to determine its applicability to a porcine liver tissue model. Statistical analyses included one-way analysis of variance to compare the temperatures reached with different NaCl concentrations and volumes with those reached without NaCl. In addition, modeled functions were evaluated for goodness of fit and the statistical significance of their coefficients. RESULTS NaCl volume and concentration had significant effects on RF-generated heating of the agar phantoms. The mean maximum temperature, 91.4 degree C +/- 0.8 (SD), was reached with 3.5 mL of 10% NaCl gel. This was significantly higher than the mean temperature reached in phantoms containing 0% NaCl gel, 40.3 degree C +/- 4.9 (P <.001). Heat increases to the maximum temperature correlated strongly with the deposited RF energy, with maximum temperatures limited by the current output of the RF generator. The response surface was defined by a generator energy-dependent region and a generator current-limited region, which were best modeled by a modified gamma-variate function and an exponential function, respectively (r2 = 0.92). This model correlated well with previously published in vivo data (r2 = 0.86). CONCLUSION Modulation of electrical conductivity has different effects on RF ablation response that are dependent on generator capabilities and the volume and concentration of NaCl pretreatment.
Collapse
Affiliation(s)
- S Melvyn Lobo
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave, Boston, MA 02215, USA
| | | | | | | | | | | |
Collapse
|
39
|
Abstract
BACKGROUND AND METHODS So-called minimally invasive techniques make percutaneous eradication of breast tumors possible, thus leading to breast-conserving treatment (BCT) without surgery. This paper reviews and discusses the feasibility of minimally invasive techniques for breast cancer. RESULTS Although a wide variety of ablation techniques have been investigated for the treatment of primary breast cancer, radiofrequency ablation (RFA) remains one of the most promising and potentially useful tools. RFA therapy results in effective cell killing in a predictable volume of tissue with a low complication rate. On the other hand, ultrasonography is useful for guiding the needle within the tumor but cannot predict the extent of thermal ablation accurately. Early post-procedural magnetic resonance imaging (MRI) may be useful for assessing whether complete tumor ablation has been achieved by RFA. Whether adequate ablation of the tumor has been achieved can be confirmed by extensive core needle sampling of the treated area. However, validation of the margin status is also important and this needs to be tackled in further studies. CONCLUSIONS There are many problems that remain before RFA therapy can be considered for conventional treatment. Further studies are needed to determine whether the use of RFA alone for local treatment of primary breast cancer will result in local recurrence and survival rates equivalent to those seen with BCT.
Collapse
|
40
|
Denys AL, De Baere T, Kuoch V, Dupas B, Chevallier P, Madoff DC, Schnyder P, Doenz F. Radio-frequency tissue ablation of the liver: in vivo and ex vivo experiments with four different systems. Eur Radiol 2003; 13:2346-52. [PMID: 12942277 DOI: 10.1007/s00330-003-1970-0] [Citation(s) in RCA: 103] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2003] [Revised: 04/07/2003] [Accepted: 05/02/2003] [Indexed: 01/27/2023]
Abstract
The aim of this study was to test the efficacy of four different radio-frequency ablation (RFA) systems in normal hepatic parenchyma in large animals. The RFA was applied to pig livers in vivo and to calf livers ex vivo using the Radionics cluster needle, RITA starburst XL needle, Radiotherapeutics Le Veen 4.0 needle, and the Berchtold 14-G saline-perfused 15-mm active-tip needle based on constructor specifications. The volume of tissue coagulation from RF was calculated from measurements of the vertical diameter (Dv) and transverse diameter (Dt). Lesion shape was characterized using the ratio between Dt/Dv. Radiotherapeutics and RITA produced in vivo lesion volume of 42+/-10, 39+/-4 cm3 with a reproducible spherical shape (Dt/Dv of 1.01+/-0.16 and 0.97+/-0.1, respectively). Radionics produced in vivo RF lesions volume of 29+/-11 cm3) with an ovoid shape (Dt/Dv 0.88+/-0.09). The RF lesions with the Berchtold device could not be assessed in vivo as 5 of 8 animals died during treatment. Ex vivo RF lesions had similar volumes with each system; however, the Radiotherapeutics device produced more reproducible shaped lesions than the other systems. In our experimental study, we found no difference between expandable needle systems in vivo. Cooled needles produced slightly smaller and ovoid shape in vivo lesions.
Collapse
Affiliation(s)
- Alban L Denys
- Department of Radiology and Interventional Radiology, Centre Hospitalier Universitaire Vaudois, 1011 Lausanne, Switzerland,
| | | | | | | | | | | | | | | |
Collapse
|
41
|
Abstract
Minimally invasive methods for destroying tissue have been investigated for more than a decade, and growing interest has emerged in small probe or needle ablative techniques. Many energy sources that freeze or heat tissue have been studied. This paper discusses radiofrequency (RF) thermal therapy as delivered by the saline-augmented ("wet" or virtual) electrode. The technique modifies the electric field distribution and the resultant heat deposition within tissues by interstitially infusing a highly conductive electrolyte solution during the application of RF energy. We consider the mechanism of action of the saline-augmented probe, with emphasis on tissue electrical impedance, temperature distributions, and how the fluid circumvents the limitations of standard "dry" probes. If optimized for the particular application, the wet electrode can produce small to large ablation volumes quickly and controllably with a single needle stick. Because there is no desiccation or extremely high temperature, the tissue is not subjected to a phase shift of carbonization, which may reduce post-treatment inflammation and improve healing. The liquid RF electrode will find applications in the interstitial treatment of various tissues, including tumors.
Collapse
Affiliation(s)
- Raymond J Leveillee
- Department of Urology, University of Miami School of Medicine, Miami, Florida 33126, USA.
| | | |
Collapse
|
42
|
Burdío F, Güemes A, Burdío JM, Navarro A, Sousa R, Castiella T, Cruz I, Burzaco O, Lozano R. Bipolar saline-enhanced electrode for radiofrequency ablation: results of experimental study of in vivo porcine liver. Radiology 2003; 229:447-56. [PMID: 14512509 DOI: 10.1148/radiol.2292020978] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
PURPOSE To evaluate whether a bipolar saline-enhanced radiofrequency (RF) ablation system embedded in one needle is able to consistently produce homogeneous and predictable areas of coagulation necrosis with or without the Pringle maneuver of vascular inflow occlusion. MATERIALS AND METHODS RF ablation (480 kHz) of the liver was performed in 24 healthy pigs by means of laparotomy: group A (n = 5), 4-cm distance between electrodes 1 and 2; group B (n = 7), 4-cm distance and the Pringle maneuver; group C (n = 5), 2-cm distance; and group D (n = 7), 2-cm distance with the Pringle maneuver. Twenty percent NaCl solution was infused continuously at a rate of 100 mL/h via each electrode during the procedure. The pigs were followed up, and they were euthanized on the 7th day. Livers were removed for histologic assessment. Time, impedance, current, power output, specific voltage of the contacts, energy output, temperatures in the liver, volume of the lesion, and energy delivered per lesion volume were determined and compared among groups. Predictability of lesion volume was evaluated with the coefficient of variability. Mean values of the variables were compared among the groups by means of one-way analysis of variance or Kruskall-Wallis test. RESULTS Impedance at the end of the RF ablation procedure was almost twofold lower than the corresponding initial value in all groups. In Pringle groups B and D, regular ellipsoids of coagulation necrosis were created (mean lesion volume, 149.50 cm3 +/- 34.26 and 69.43 cm3 +/- 15.48, respectively). In non-Pringle groups A and C, the shape of coagulation necrosis was influenced by the vessels encountered, and mean lesion size was lower than that in the Pringle groups (P <.01). The coefficient of variability of lesion size was lower in the Pringle groups (23% and 22%, respectively) than that in the non-Pringle groups (75% and 30%, respectively). CONCLUSION The bipolar saline-enhanced RF ablation method produces homogeneous and predictable areas of coagulation necrosis between two electrodes, regardless of the distance between them, preferably with vascular inflow occlusion.
Collapse
Affiliation(s)
- Fernando Burdío
- Department of Surgery A, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain.
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Giorgio A, Tarantino L, de Stefano G, Scala V, Liorre G, Scarano F, Perrotta A, Farella N, Aloisio V, Mariniello N, Coppola C, Francica G, Ferraioli G. Percutaneous sonographically guided saline-enhanced radiofrequency ablation of hepatocellular carcinoma. AJR Am J Roentgenol 2003; 181:479-84. [PMID: 12876030 DOI: 10.2214/ajr.181.2.1810479] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE The purpose of our study was to analyze the efficacy, side effects, and short-term complications of saline-enhanced percutaneous radiofrequency ablation performed under sonographic guidance in a series of cirrhotic patients with hepatocellular carcinoma. SUBJECTS AND METHODS. Between September 2000 and June 2002, 84 patients (55 men and 29 women) with cirrhosis who ranged in age from 48 to 74 years (mean age, 64 years) and who had 95 hepatocellular carcinomas (seven patients had two tumors and two patients had three tumors) were treated with high frequency-induced thermotherapy. The diameters of the tumors ranged from 1.5 to 8.5 cm (mean, 3.6 cm). The efficacy of radiofrequency ablation was evaluated with triphasic contrast-enhanced CT performed 4 weeks after the procedure. RESULTS Posttreatment CT showed complete necrosis in 73 (77%) of 95 hepatocellular carcinomas in 62 patients. Complete necrosis based on tumor size was seen in 40 (95%) of 42 tumors with diameters equal to or smaller than 3 cm, 32 (71%) of 45 tumors with diameters between 3.1 and 5.0 cm, and one (12%) of eight tumors with diameters larger than 5.0 cm. Twenty-two hepatocellular carcinomas showed incomplete necrosis. None of the patients experienced major complications. Four patients were lost to follow-up. The length of the follow-up period ranged from 4 to 22 months (mean, 10 months). One patient died 8 months after the radiofrequency ablation treatment. All the remaining patients are still alive. During the follow-up period, eight (10%) of 80 patients showed a local recurrence on sonography and CT. CONCLUSION Our experience suggests that percutaneous radiofrequency ablation of hepatocellular carcinoma with high frequency-induced thermotherapy is safe and effective in the treatment of hepatocellular carcinomas equal to or smaller than 3 cm, fairly effective for hepatocellular carcinomas between 3 and 5 cm, and ineffective for tumors larger than 5 cm.
Collapse
Affiliation(s)
- Antonio Giorgio
- Interventional Ultrasound Service, D. Cotugno Hospital, Viale Colli Aminei 491, Naples 80131, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Tsuda M, Rikimaru H, Majima K, Yamada T, Saito H, Ishibashi T, Takahashi S, Miyachi H, Endoh M, Yamada S. Time-related changes of radiofrequency ablation lesion in the normal rabbit liver: findings of magnetic resonance imaging and histopathology. Invest Radiol 2003; 38:525-31. [PMID: 12874519 DOI: 10.1097/01.rli.0000073447.32361.b3] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
RATIONALE AND OBJECTIVES To study time-related magnetic resonance imaging (MRI) and histopathological findings after radiofrequency ablation (RFA) in the normal liver. METHODS Under ultrasound guidance, RFA was performed in 22 rabbits with a 15-gauge expandable probe inserted into the liver. The RF power was applied at 10 W initially with a 5-W increment every minute until RF power "roll-off" occurred. The rabbits subjected to postmortem MRI at 3 days (n = 6), 2 weeks (n = 6), 4 weeks (n = 6), and 12 weeks (n = 4) after RFA. Spin-echo (SE) T(1)-weighted image (WI) (TR/TE=500/12) and fast SE T2-WI (TR/TE= 3500/99) were obtained. The liver specimens were excised and processed for conventional histologic study. The MRI and pathologic findings were compared qualitatively and quantitatively. RESULTS The lesion diameters measured with MRI and liver specimen were well correlated (P < 0.05). The coagulated regions presented 2 of 4 laminar patterns on T1/T2-WI 3 days after RFA, and 2 of 3 laminar patterns on T1/T2-WI 2 to 4 weeks after RFA. 12 weeks after RFA, the signal intensity in coagulated regions increased on T1-WI with a 2-laminar pattern still visible on T2-WI, the same as that of 2 to 4 weeks. The observed pathologic changes (enlarged sinusoids, marginal fibrous tissue and hepatocyte degeneration) could be responsible for the MRI laminar patterns and signal intensity changes. CONCLUSION The time-related pathologic changes of RFA lesions in rabbit livers can be reflected as laminar patterns on MR images. Understanding of the zone structure of the lesions is useful for the evaluation of follow-up MRI.
Collapse
Affiliation(s)
- Masashi Tsuda
- Department of Diagnostic Radiology, Tohoku University Graduated School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
|
46
|
Large hepatic ablation with bipolar saline-enhanced radiofrequency: an experimental study in in vivo porcine liver with a novel approach. J Surg Res 2003; 110:193-201. [PMID: 12697400 DOI: 10.1016/s0022-4804(02)00091-4] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
SUMMARY BACKGROUND DATA Radiofrequency ablation (RFA) is a relatively new technology for the local destruction of liver tumors. Development of recent devices has enabled the creation of larger lesions. Nevertheless, treating liver tumors larger than 2.5 cm in diameter often requires multiple overlapping ablations to encompass the tumor and the surrounding healthy tissue rim with an increasing risk of local recurrence. MATERIAL AND METHODS RFA (480 kHz) of the liver using our method was undertaken on a total number of 15 healthy farm pigs with (Group B, n = 8) or without (Group A, n = 5) the Pringle maneuver via laparotomy. The pigs were followed and euthanized on the seventh day of the experiment. Livers were removed for histological assessment. Time of the procedure, impedance, current, power output, energy output, temperatures in the liver, central temperature of the animal, volume size of the lesion, and delivered energy per lesion volume were determined and compared among groups. Additionally a regularity ratio (RR) was determined by gross examination of the specimen and scored (0-3) taking into account regularity and predictability of the ablation with pathologic assessment. RESULTS With both methods, ellipsoid lesions were created between the two probes. In both groups tissue impedance fell with time (r = -0.47, P < 0.01 and r = -0.34, P < 0.05, in Groups A and B, respectively). The mean lesion size achieved with the Pringle maneuver was the largest lesion size described in the literature for any RFA method in vivo and was greater in Group B than in Group A (123.22 cm(3) +/- 49.62 and 52.40 cm(3) +/- 23.59, respectively, P < 0.05). A better regularity and predictability evaluated by RR was observed in Group B compared to Group A (1.88 +/- 1.35 and 0.40 +/- 0.55, respectively, P < 0.05). Five major complications were described and attributed primarily to failure in isolation from hypertermic lesions. CONCLUSIONS Our new bipolar saline-enhanced electrode with Pringle maneuver achieves large hepatic ablations in in vivo pig liver. These large lesions are well-tolerated by the animal when thermal injuries to adjacent structures are avoided.
Collapse
|
47
|
Gillams AR. Radiofrequency ablation in the management of liver tumours. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2003; 29:9-16. [PMID: 12559069 DOI: 10.1053/ejso.2002.1346] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- A R Gillams
- Department of Medical Imaging, The Middlesex Hospital, Mortimer Street, London, W1T 3AA, UK.
| |
Collapse
|
48
|
Kettenbach1 J, Wolf1 F, Weigner2 M, Lechner3 G, Goldberg4 SN. Percutaneous Radiofrequency Ablation of Liver Metastases: Applications and Potential Indications. Eur Surg 2002. [DOI: 10.1046/j.1563-2563.2002.02077.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
49
|
Mulier S, Mulier P, Ni Y, Miao Y, Dupas B, Marchal G, De Wever I, Michel L. Complications of radiofrequency coagulation of liver tumours. Br J Surg 2002; 89:1206-22. [PMID: 12296886 DOI: 10.1046/j.1365-2168.2002.02168.x] [Citation(s) in RCA: 487] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Radiofrequency coagulation (RFC) is being promoted as a novel technique with a low morbidity rate in the treatment of liver tumours. The purpose of this study was to assess critically the complication rates of RFC in centres with both large and limited initial experience, and to establish causes and possible means of prevention and treatment. METHODS This is an exhaustive review of the world literature (articles and abstracts) up to 31 December 2001; 82 independent reports of RFC of liver tumours were analysed. RESULTS In total, 3670 patients were treated with percutaneous, laparoscopic or open RFC. The mortality rate was 0.5 per cent. Complications occurred in 8.9 per cent: abdominal bleeding in 1.6 per cent, abdominal infection in 1.1 per cent, biliary tract damage in 1.0 per cent, liver failure in 0.8 per cent, pulmonary complications in 0.8 per cent, dispersive pad skin burn in 0.6 per cent, hepatic vascular damage in 0.6 per cent, visceral damage in 0.5 per cent, cardiac complications in 0.4 per cent, myoglobinaemia or myoglobinuria in 0.2 per cent, renal failure in 0.1 per cent, tumour seeding in 0.2 per cent, coagulopathy in 0.2 per cent, and hormonal complications in 0.1 per cent. The complication rate was 7.2, 9.5, 9.9 and 31.8 per cent after a percutaneous, laparoscopic, simple open and combined open approach respectively. The mortality rate was 0.5, 0, 0 and 4.5 per cent respectively. CONCLUSION The morbidity and mortality of RFC, while low, is higher than previously assumed. With adequate knowledge, many complications are preventable.
Collapse
Affiliation(s)
- S Mulier
- Department of General Surgery, University Hospital Mont-Godinne, Catholic University of Louvain, Belgium.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Yim APC, Rendina EA, Hazelrigg SR, Chow LTC, Lee TW, Wan S, Arifi AA. A new technological approach to nonanatomical pulmonary resection: saline enhanced thermal sealing. Ann Thorac Surg 2002; 74:1671-6. [PMID: 12440628 DOI: 10.1016/s0003-4975(02)03901-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND This is the first clinical report on the feasibility study of two new devices (monopolar Floating Ball and bipolar Sealing Forceps; TissueLink Medical Inc, Dover NH) that incorporated the novel technology of saline enhanced thermal sealing. METHODS From December 2000 to December 2001, 25 patients (mean age, 54.8 years) with peripheral lung nodules planned for either diagnostic or therapeutic wedge resection were recruited for the study. When the nodule lay deep to a flat lung surface, video-assisted thoracic surgical resection using the modified Perelman technique with the Floating Ball (TissueLink Medical Inc) was preferred. In other patients, the Sealing Forceps (TissueLink Medical Inc) were used for video-assisted thoracic surgical wedge resection. RESULTS There were no mortality or major intraoperative complications. The Floating Ball was used exclusively in 11 patients; the Sealing Forceps were used in 9 patients; and a combination of the two devices was used in 5 patients. The mean operation time was 70.3 minutes. Average chest drain duration was 3.9 days, and postoperative hospital stay was 5.2 days. There were 2 patients with persistent air leak more than 1 week, one who resolved spontaneously, and the other who required reoperation for control. One patient had pulmonary embolism after a technically uneventful procedure. There have been no late complications after an average follow-up of 10 months. CONCLUSIONS The devices appear to be technically safe. The Floating Ball has definite advantages over the conventional diathermy and can be adapted to the Perelman procedure using the video-assisted thoracic surgical approach. The Sealing Forceps hold promise to reduce overall consumable costs compared with conventional staplers. These devices should complement the surgeon's existing armamentarium. Comparative studies with conventional instruments are warranted to further define the role of these new devices in thoracic operations.
Collapse
|