1
|
Terranella S, Fefferman M, Zhang Y, Wright K, Hollinger E, Olaitan O, Hertl M, Jensik S, Keen R, Chan E. Economic evaluation of suture versus clip anastomosis in arteriovenous fistula creation. J Vasc Surg 2020; 73:2098-2104. [PMID: 33249206 DOI: 10.1016/j.jvs.2020.10.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 10/20/2020] [Indexed: 11/20/2022]
Abstract
OBJECTIVE Techniques such as the use of nonpenetrating vascular clips for arteriovenous fistula (AVF) anastomotic creation have been developed in an effort to reduce fistula-related complications. However, the outcomes data for the use of clips have remained equivocal, and the cost evaluations to support their use have been largely theoretical. Therefore, the present study aimed to determine both the clinical and the cost outcomes of AVFs created with nonpenetrating vascular clips compared with the continuous suture technique during a 10-year period at a single institution. METHODS All patients undergoing AVF creation in the upper extremity from 2009 through 2018 were retrospectively analyzed. The patient demographics and AVF outcomes were collected and compared stratified by the surgical technique used. A cost analysis was performed of a subgroup of patients from 2013 to 2018. RESULTS During the 10-year study period, 916 AVFs were created (79% using the continuous suture technique and 21% using nonpenetrating vascular clips). Patient demographics and comorbid conditions did not differ between the two groups, and no differences were present in maturation, primary patency, assisted primary patency, or complication rates between the two groups at 1 year. The suture group had a shorter time to maturation (4.3 months vs 5.5 months; P < .01) and improved secondary patency compared with the clip group (77.13% vs 69.59%; P = .03) The cost analysis of the procedures revealed a significant difference in direct costs (suture, $1389.26 vs clip, $1716.51; P < .01) and contribution margin (suture, $1770.19 vs clip, $1128.36; P < .01) for the two groups. CONCLUSIONS Both suture and clip techniques in AVF creation demonstrated equivalent rates of maturation, primary patency, assisted primary patency, and complications at 1 year with higher expense associated with the use of clips. Thus, in an effort to reduce the economic burden of healthcare in the United States, the findings from the present study support the preferential use of the standard polypropylene suture technique when creating upper extremity AVFs.
Collapse
Affiliation(s)
- Samantha Terranella
- Division of Surgery, Department of Surgery, Rush University Medical Center, Chicago, Ill.
| | - Marie Fefferman
- Division of Surgery, Department of Surgery, Rush University Medical Center, Chicago, Ill
| | - Yanyu Zhang
- Bioinformatics and Biostatistics Core, Rush University Medical Center, Chicago, Ill
| | - Kathleen Wright
- Financial Planning and Decision Support, Rush University Medical Center, Chicago, Ill
| | - Edward Hollinger
- Division of Surgery, Department of Surgery, Rush University Medical Center, Chicago, Ill
| | - Oyedolamu Olaitan
- Division of Surgery, Department of Surgery, Rush University Medical Center, Chicago, Ill
| | - Martin Hertl
- Division of Surgery, Department of Surgery, Rush University Medical Center, Chicago, Ill
| | - Stephen Jensik
- Division of Surgery, Department of Surgery, Rush University Medical Center, Chicago, Ill
| | - Richard Keen
- Department of Surgery, John H. Stroger Hospital of Cook County, Chicago, Ill
| | - Edie Chan
- Division of Surgery, Department of Surgery, Rush University Medical Center, Chicago, Ill
| |
Collapse
|
2
|
Saad H, Krisht KM, Yang WH, Aboud E, Krisht AF. Rapid M1 Hemoclips Arteriotomy Repair After Emergency Coil Embolectomy. Oper Neurosurg (Hagerstown) 2018. [DOI: 10.1093/ons/opx187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
BACKGROUND
The vascular closure staple clips have been studied in animal models and shown to have comparable results with sutured repair when it comes to the healing process, degree of vessel narrowing, and risk of thrombosis. However, they are clearly superior when the speed of application is taken into account, and they were clinically used in many vascular repair processes. Nevertheless, their usefulness in intracranial vascular surgery has not been described.
OBJECTIVE
To describe the usefulness of hemoclips in fast and efficient repair of medium-sized and large intracranial vessels.
METHODS
Two female patients diagnosed with giant symptomatic cavernous sinus aneurysms were undergoing elective endovascular procedures that were complicated by the dislodgement of coils into the M1 segment of the middle cerebral artery. Both patients were treated performing M1 arteriotomies and coil embolectomy. To avoid prolonged temporary occlusion in the M1 perforator's territory, the arteriotomies were repaired using microhemoclips in less than 10 min with re-establishment of flow.
RESULTS
In both patients, flow was re-established in the M1 segments. In 1 patient, the coils extended to the temporal M2 causing intimal injury and leading to diminished flow. M1 segments in both patients were patent on later angiographic studies.
CONCLUSION
We describe the advantage of emergent cerebrovascular arteriotomy and embolectomy in a rapid repair process that helped avoid massive ischemic injury. We believe this technique should be added to the armamentarium of neurosurgical cerebrovascular options.
Collapse
Affiliation(s)
- Hassan Saad
- Arkansas Neuroscience Institute, CHI St. Vincent Infirmary, Little Rock, Arkansas
| | - Khaled M Krisht
- Department of Neurosurgery, Baptist Health, Montgomery, Alabama
- Department of Neurosurgery, University of Alabama at Birmingham, Birmingham, Alabama
| | - Wei-hsun Yang
- Division of Neurosurgery, Department of Surgery, Chang Gung Memorial Hospital, Chia-Yi Center, Putz, Taiwan
| | - Emad Aboud
- Arkansas Neuroscience Institute, CHI St. Vincent Infirmary, Little Rock, Arkansas
| | - Ali F Krisht
- Arkansas Neuroscience Institute, CHI St. Vincent Infirmary, Little Rock, Arkansas
| |
Collapse
|
3
|
Ross JR. Creation of Native Arteriovenous Fistulas with Interrupted Anastomoses Using a Self-Closing Clip Device - One Clinic's Experience. J Vasc Access 2018; 3:140-6. [PMID: 17639476 DOI: 10.1177/112972980200300402] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
The nitinol U-CLIP™ Anastomotic Device (Coalescent Surgical, Inc., Sunnyvale, CA) is a self-closing penetrating vascular clip that reduces suture management and eliminates knot tying, thus enabling rapid and precise interrupted suture placement and facilitating creation of an optimal vascular anastomosis. This report describes the use of U-CLIP devices in the surgical creation of native arteriovenous fistulas in 68 chronic hemodialysis patients. Overall, 61 of the 65 fistulas created matured successfully within 8–9 weeks. Radial cephalic fistulas: 93% were mature at 8 weeks. Brachiocephalic fistulas: 69% were mature at 8 weeks. One-stage basilic vein transposition: 100% were mature at 9 weeks. Two-stage basilic vein transposition: 100% were mature at 8 weeks after second stage. The results in this report show the excellent performance of U-CLIP vascular clips in the creation of several types of native arteriovenous fistulas in chronic hemodialysis patients. The fistulas created using the U-CLIP devices had a high maturation rate within a relatively short time period, and provided uniformly high flow rates. The patients in this study were a challenging population, with a high incidence of diabetes mellitus (81% of the patients) and vein sizes that were smaller than typically used for fistula creation. The U-CLIP™ Anastomotic Device offers the opportunity to create superior interrupted anastomoses for AV fistulas, even in patients who would otherwise be considered poor candidates for fistula creation.
Collapse
Affiliation(s)
- J R Ross
- General Surgery, Bamberg County Hospital, Bamberg, South Carolina - USA
| |
Collapse
|
4
|
Wang Y, Xin Z, Pan B, Lv SC, Zhang XM, Zhang ZH, Li LX, Li XL, He Q. Venous anastomosis using a non-penetrating vascular closure system in orthotopic liver transplantation. Clin Transplant 2017; 31. [PMID: 28944583 DOI: 10.1111/ctr.13123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/20/2017] [Indexed: 11/29/2022]
Affiliation(s)
- Yuan Wang
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Zhao Xin
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Bing Pan
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Shao-cheng Lv
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Xing-mao Zhang
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Zhi-hua Zhang
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Li-xin Li
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Xian-liang Li
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| | - Qiang He
- Department of Hepatobiliary Surgery; Beijing Chaoyang Hospital Affiliated to Capital Medical University; Beijing China
| |
Collapse
|
5
|
Kondo R, Itoda Y, Panthee N, Inui A, Ashiba H, Ando T, Kobayashi E, Sakuma I, Ono M. A New Suturing Device for Small Arteries. Int Heart J 2016; 57:323-6. [PMID: 27181185 DOI: 10.1536/ihj.15-412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Endoscope-assisted surgery and robot-assisted surgery are not common in cardiac surgery, particularly coronary artery bypass grafting, because of the complex nature of the procedures. We developed a new suturing device that allows for easy performance of such cardiac surgeries in comparison with conventional suturing methods. A total of 63 rabbits were used in this study. The right carotid artery was bypassed using the same side of the jugular vein under endoscopic guidance. Of these, 48 rabbits were operated on using the new devices and 15 rabbits were operated on using conventional polypropylene sutures. The proximal suturing time was 16.6 ± 5.3 minutes in the group that underwent surgery using the new device (group D) and 22.8 ± 7.6 minutes in the control group (group C; P < 0.05). The distal suture time was 16.3 ± 4.2 minutes in group D and 22.8 ± 6.0 minutes in group C (P < 0.05). The operation time was 113.0 ± 15.8 minutes in group D and 136.7 ± 20.6 minutes in group C (P < 0.05). Graft flow was 19.9 ± 12.8 mL/minute in group D and 12.1 ± 11.3 mL/minute in group C (P < 0.05). Thus, the operation time and the suture time differed significantly between the groups. This device provides advantages in endoscopic surgery compared to the conventional suture method.
Collapse
Affiliation(s)
- Ryoichi Kondo
- Department of Cardiac Surgery, School of Medicine, The University of Tokyo
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Comparison of Nonpenetrating Titanium Clips versus Continuous Polypropylene Suture in Dialysis Access Creation. Ann Vasc Surg 2016; 32:15-9. [DOI: 10.1016/j.avsg.2015.11.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Revised: 11/18/2015] [Accepted: 11/24/2015] [Indexed: 11/17/2022]
|
7
|
Development of a suturing device for anastomosis for small caliber arteries. J Artif Organs 2013; 17:88-94. [PMID: 24366811 DOI: 10.1007/s10047-013-0749-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2013] [Accepted: 11/29/2013] [Indexed: 10/25/2022]
Abstract
The use of minimally invasive and robotic operations has been increasing for coronary artery bypass surgery; however, no suturing devices have been universally adopted for use in these procedures. We developed a new suturing device that enables omission of manual ligation after a running suture. Twenty-two rabbits were used in this study. In 22 rabbits, the right carotid artery was bypassed using an autologous jugular vein graft. Half of the animals were operated on using the new device and the other half using conventional suturing methods. Postoperative evaluations were performed at 1, 3, and 6 months. Suturing time was 15.6 ± 2.4 min in the device group and 16.6 ± 4.4 min in the control group (p = 0.34). Graft patency and blood flow measurements were not significantly different between the two groups. Histopathological examination of the anastomotic site showed common inflammatory responses in both groups. No particular histopathological change was seen related to the device. In conclusion, the safety of the new suturing device was confirmed, and its efficacy was equal to that of the conventional suturing technique.
Collapse
|
8
|
Growing Cava Vein Anastomosis: Comparison of Cross-Clamping and Suture Times Using VCS Metallic Clips, Interrupted Nonabsorbable, or Continuous Absorbable Suturing Techniques. Ann Vasc Surg 2013; 27:947-53. [DOI: 10.1016/j.avsg.2013.03.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2011] [Accepted: 03/19/2013] [Indexed: 11/23/2022]
|
9
|
Comparison of various methods of vessel ligation: what is the safest method? Surg Endosc 2013; 27:3129-38. [DOI: 10.1007/s00464-013-2866-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Accepted: 02/06/2013] [Indexed: 10/27/2022]
|
10
|
Carmen calles vázquez M, Abellán rubio E, Crisóstomo ayala V, Fernanda martín cancho M, Francisco M, Margallo S, Usón gargallo J. Clips metálicos de titanio: una técnica de sutura más rápida y fácil de utilizar que las suturas convencionales en autotrasplantes renales heterotópicos en cerdos en crecimiento. Actas Urol Esp 2009; 33:76-82. [DOI: 10.1016/s0210-4806(09)74006-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
11
|
Lorincz BB, Kálmán E, Gerlinger I. KTP-532 laser-assisted microvascular anastomosis (experimental animal study). Eur Arch Otorhinolaryngol 2007; 264:823-8. [PMID: 17453225 DOI: 10.1007/s00405-007-0317-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2006] [Accepted: 04/03/2007] [Indexed: 11/30/2022]
Abstract
Former animal studies on laser-assisted microvascular anastomosis performed with CO(2)-, argon-, diode-, Holmium:YAG- and Nd:YAG-lasers had already proven the stability of the anastomotic sites. Tissue damage remained minimal along the anastomosis, while duration of the surgeries decreased significantly compared to that of traditionally implemented microvascular sutures. In addition to this, foreign body reaction next to end-to-end anastomosis appeared to be minimal due to fewer traditional stitches. This animal study was designed in order to investigate the durability and the histological properties of microvascular anastomosis assisted by KTP-532 laser. Twenty-one Wistar albino rats were used: in nine animals the KTP-laser-assisted microvascular anastomosis was carried out on the femoral artery. Those nine animals were divided into three groups and each of them consisted of three rats. The animals in these three groups were sacrificed 4 h, 1 and 4 weeks following the surgery, respectively. In three additional animals laser-assisted microvascular anastomosis was done on the abdominal aorta. Conventional microvascular sutures were carried out on femoral arteries of further nine animals in the control group. The healing process of the femoral arteries is documented with figures of histological slides both in the laser-treated and in the conventionally operated group of rats. The KTP-laser-assisted microvascular anastomosis failed on the abdominal aorta, as strong bleedings occurred after the traditional sutures had been taken out. However, the coagulative effect of the KTP-laser could still be used. The authors share the opinion that the success of the laser-assisted end-to-end microvascular anastomosis does not depend on the wavelength of the applied laser, but can be affected by both the calibre of the vessel and the intraluminal pressure.
Collapse
Affiliation(s)
- Balázs B Lorincz
- Department of Otolaryngology and Head and Neck Surgery, Medical School, University of Pécs, Munkácsy M. utca 2, 7621, Pécs, Hungary.
| | | | | |
Collapse
|
12
|
Calles-Vázquez MC, Viguera FJ, Crisóstomo V, Usón-Gargallo J. Vascular Closure Stapler Clip Anastomosis Decreases Aortic Cross-Clamping Time Compared to Interrupted Nonabsorbable and Running Absorbable Sutures in Growing Pigs. Ann Vasc Surg 2006; 20:35-41. [PMID: 16378146 DOI: 10.1007/s10016-005-9321-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The latest generation in titanium clip application systems, the vascular closure staples (VCS) system avoids intimal lesions and therefore minimizes the subsequent hyperplastic reaction, while at the same time enhancing distensibility and vascular growth. Moreover, VCS clips allow the surgeon to perform vascular anastomosis easily and faster than conventional suture. This system may become the option of choice for vascular reconstruction in pediatric surgery where, as in the case of aortic and transplant surgery, decreasing vascular occlusion times may influence the outcomes. The aim of this study was to determine whether VCS metallic clips would allow shorter anastomosis times than conventional interrupted polypropylene or running Dexon suturing in end-to-end anastomosis performed in the abdominal aorta of young pigs. Twenty-four domestic swine, 45 days old, were used for this study. All animals were subjected to an end-to-end anastomosis in the abdominal aorta using VCS clips, interrupted polypropylene, or running Dexon suture. Aortic cross-clamping time was significantly shorter in the VCS clips group (4.02 +/- 0.72 min), compared to interrupted polypropylene (21.89 +/- 1.93 min) or running Dexon (9.82 +/- 3.97 min) suture. VCS clips are easy to use, and therefore may aid surgeons to significantly decrease the time needed for performing an end-to-end anastomosis in the abdominal aorta, thus decreasing cross-clamping time when compared to interrupted polypropylene or running Dexon sutures.
Collapse
|
13
|
Ott B, Constantinescu MA, Erni D, Banic A, Schaffner T, Frenz M. Intraluminal laser light source and external solder: In vivo evaluation of a new technique for microvascular anastomosis. Lasers Surg Med 2004; 35:312-6. [PMID: 15493022 DOI: 10.1002/lsm.20096] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND AND OBJECTIVES Current laser-assisted end-to-end anastomoses are performed by irradiating the vessel wall from outside after additional fixation with three to six sutures. These sutures are needed to provide adequate approximation of the vessel stumps. We present a new laser soldering technique that is based on an intraluminal laser light source centered in a balloon catheter, and external application of a solder. This technique was applied in vivo in order to test its feasibility under clinical conditions. STUDY DESIGN/MATERIALS AND METHODS Seven white pigs were treated with a total of fourteen end-to-end laser-anastomoses of their saphenous arteries having outer diameters of 2 mm. The vessels were stented over an intraluminal balloon catheter, which was maximally dilated and which allowed for a precise approximation of the vascular stumps. An 808 nm diode laser was coupled into a specially designed optical fiber producing a 360 degrees radiation ring inside the balloon catheter. An indocyanine green (ICG) doped liquid albumin solder was applied on the external surface of the vascular stumps. Laser soldering was achieved by irradiating with a 808 nm laser diode for 75 seconds. Tightness of the anastomoses was evaluated by clamping the artery distal to the anastomosis for 1 hour, and patency was tested over an observation period of 3 hours, during which the animals were heparinized. Thereafter, the anastomoses were harvested for histomorphological examination. RESULTS All anastomoses remained patent over the entire observation period. Some leakage was observed in three anastomoses, which was explained by a deviation of the illumination fiber from the center of the balloon leading to an inhomogeneous irradiation of the vessel wall. Histology revealed perfect adaptation of the vascular stumps. A segment of denaturated vascular collagen was observed, that corresponded to the irradiated, solder-covered zone. CONCLUSION Patent, maximally dilated and well adapted microvascular anastomoses could be obtained without the need of stay sutures. A well centered laser light source is indispensable for avoiding inhomogenous welding, thus causing leakage.
Collapse
Affiliation(s)
- Beat Ott
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | | | | | | | | | | |
Collapse
|
14
|
Zeebregts CJ, Kirsch WM, van den Dungen JJ, Zhu YH, van Schilfgaarde R. Five years' world experience with nonpenetrating clips for vascular anastomoses. Am J Surg 2004; 187:751-60. [PMID: 15191871 DOI: 10.1016/j.amjsurg.2003.08.028] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2003] [Revised: 08/11/2003] [Indexed: 11/22/2022]
Abstract
BACKGROUND A new sutureless technique has been introduced clinically to facilitate the process of vascular reconstruction and improve patency. The Vessel Closure System (VCS) is nonpenetrating, creates an elastomeric everted anastomosis, and is easily and reproducibly applied. The objective of this report is to review the published world experience that has accrued regarding these clips with attention to the assets, liabilities, and pitfalls associated with the new technology. DATA SOURCES Medline search and manual cross-referencing were performed, after which 61 original articles were identified on the use of VCS clips for vascular anastomoses. RESULTS Advantages of the clips compared with sutures include the technical ease of application, the reduced anastomotic time, the superior hemodynamics, and the improved healing pattern of the anastomosis. Disadvantages include the potential problems in atherosclerotic vessels, lack of prospective randomized long-term follow-up, and initial costs. The best clinical results have been achieved in microvascular repair, as well as with vascular access and transplantation surgery. CONCLUSIONS The VCS clip technology has become an accepted vascular anastomosing technique, which in future could lead to the use of clips as a standard approach and the use of sutures only in case of severe atherosclerosis and other circumstances in which vessel edges are difficult to evert.
Collapse
Affiliation(s)
- Clark J Zeebregts
- Department of Surgery, University Hospital Groningen, PO Box 30001, 9700 RB Groningen, The Netherlands.
| | | | | | | | | |
Collapse
|
15
|
Tiwari A, Cheng KS, Salacinski H, Hamilton G, Seifalian AM. Improving the patency of vascular bypass grafts: the role of suture materials and surgical techniques on reducing anastomotic compliance mismatch. Eur J Vasc Endovasc Surg 2003; 25:287-95. [PMID: 12651165 DOI: 10.1053/ejvs.2002.1810] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND compliance mismatch is an important factor in the development of myointimal hyperplasia in both coronary and vascular anastomoses. This mismatch may be reduced by the use of newer suture materials and techniques. This review discusses the current techniques and materials used to date in generating anastomoses in both coronary and vascular applications and to correlate these with the degree of inherent compliance achieved. METHODS PubMed, ISIS, CAS and PAS database searches were performed. Other articles were cross-referenced. RESULTS AND CONCLUSION continuous suture is still the most used technique in both cardiac and vascular surgery for the generation of anastomoses due to the reduced time and improved haemostasis. However, continuous suture results in a greater compliance mismatch than the interrupted technique. Vein cuffs and patches improve compliance and transmission of pulsatile blood flow and offer improvement of graft patency. Alternative to sutures are biological glue, clips and laser generated solders all of which have shown promising results, but further work is required before they become applicable for routine use.
Collapse
Affiliation(s)
- A Tiwari
- Tissue Engineering Centre, University Department of Surgery, Royal Free and University College Medical School, University College London and The Royal Free Hospital, London, UK
| | | | | | | | | |
Collapse
|
16
|
Clips metálicos VCS: una técnica de sutura más rápida y fácil de utilizar que la sutura convencional en reconstrucciones de vasos en crecimiento. ANGIOLOGIA 2003. [DOI: 10.1016/s0003-3170(03)74831-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
17
|
Zeebregts CJAM. Regarding "A comparison of para-anastomotic compliance profiles after vascular anastomosis: nonpenetrating clips versus standard sutures". J Vasc Surg 2002; 35:626-7. [PMID: 11877728 DOI: 10.1067/mva.2002.121062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
18
|
Komori K, Shoji T, Furuyama T, Yonemitsu Y, Mori E, Yamaoka T, Matsumoto T, Sugimachi K. Non-penetrating Vascular Clips Anastomosis Inhibited Intimal Thickening Under Poor Runoff Conditions in Canine Autogenous Vein Grafts. Eur J Vasc Endovasc Surg 2001; 21:241-7. [PMID: 11352683 DOI: 10.1053/ejvs.2001.1297] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Late graft failure is still a significant problem, particularly in cases with poor runoff vessels. The main cause of late graft failure is intimal thickening of the anastomotic region. Vascular closure system (VCS) clips may provide ideal anastomosis, since they do not penetrate the wall. Therefore, we examined whether the VCS clips affect intimal thickening under poor runoff conditions in the canine autogenous vein grafts. METHODS A canine poor runoff model was prepared at both femoral veins. Four weeks after the first surgical procedure, two groups were established according to the two different methods of anastomosis employed. The right femoral vein graft was performed using polypropylene sutures, conventional surgical anastomosis (control group), while the left femoral vein graft was performed using VCS clips anastomosis (VCS group). Four weeks after grafting, the vein grafts were removed and the intimal thickening of proximal, distal anastomosis and midportion of the vein grafts were examined histologically. RESULTS In the control group, flow rate and variation were 26+/-8 ml/min and 51+/-10 dynes/cm(2), respectively. In the VCS group, the flow rate and variation were 23+/-11 ml/min and 44+/-14 dynes/cm(2), respectively. There were no significant differences between the two groups. The average value of intimal thickening of both the anastomotic region and the midportion of the vein graft in the VCS group was significantly inhibited compared to that of the control group. The number of positive cells of masson trichrome stain in the VCS group was significantly less than that of the control group. CONCLUSIONS These experiments indicate that VCS clips significantly inhibit intimal thickening under poor runoff conditions in canine autogenous vein grafts to a greater extent compared to suture-constructed anastomosis. One mechanism that may account for the decreased intimal thickening is the inhibition of the expression of transforming growth factor-beta (TGF-beta), because the number of positive cells of masson trichrome stain in the VCS group was significantly less than that of the control group.
Collapse
Affiliation(s)
- K Komori
- Department of Surgery and Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812, Japan
| | | | | | | | | | | | | | | |
Collapse
|