1
|
Williams-Pavlantos K, Brigham-Stinson NC, Becker ML, Wesdemiotis C. Application of surface-layer matrix-assisted laser desorption/ionization mass spectrometry imaging to pharmaceutical-loaded poly(ester urea) films. Anal Chim Acta 2023; 1283:341963. [PMID: 37977787 PMCID: PMC10657383 DOI: 10.1016/j.aca.2023.341963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 09/17/2023] [Accepted: 10/25/2023] [Indexed: 11/19/2023]
Abstract
Polymer thin films are often used in transdermal patches as a method of continuous drug administration for patients with chronic illness. Understanding the drug segregation and distribution within these films is important for monitoring proper drug release over time. Surface-layer matrix-assisted laser desorption/ionization mass spectrometry imaging (SL-MALDI-MSI) is a unique analytical technique that provides an optical representation of chemical compositions that exist at the surface of polymeric materials. Solvent-free sublimation is employed for application of matrix to the sample surface, so that only molecules in direct contact with the matrix layer are detected. Here, these methodologies are utilized to visualize variations in drug concentration at both the air and substrate interface in pharmaceutical-loaded polymer films.
Collapse
Affiliation(s)
| | | | - Matthew L Becker
- Department of Chemistry, Duke University, Durham, NC, 27708, USA; Thomas Lord Department of Mechanical Engineering & Materials Science, Duke University, Durham, NC, 27708, USA; Departments of Biomedical Engineering and Orthopedic Surgery, Duke University, Durham, NC, 27708, USA
| | - Chrys Wesdemiotis
- Department of Chemistry, The University of Akron, Akron, OH, 44325, USA.
| |
Collapse
|
2
|
Abstract
Analysis of intact proteins by native mass spectrometry has emerged as a powerful tool for obtaining insight into subunit diversity, post-translational modifications, stoichiometry, structural arrangement, stability, and overall architecture. Typically, such an analysis is performed following protein purification procedures, which are time consuming, costly, and labor intensive. As this technology continues to move forward, advances in sample handling and instrumentation have enabled the investigation of intact proteins in situ and in crude samples, offering rapid analysis and improved conservation of the biological context. This emerging field, which involves various ion source platforms such as matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) for both spatial imaging and solution-based analysis, is expected to impact many scientific fields, including biotechnology, pharmaceuticals, and clinical sciences. In this Perspective, we discuss the information that can be retrieved by such experiments as well as the current advantages and technical challenges associated with the different sampling strategies. Furthermore, we present future directions of these MS-based methods, including current limitations and efforts that should be made to make these approaches more accessible. Considering the vast progress we have witnessed in recent years, we anticipate that the advent of further innovations enabling minimal handling of MS samples will make this field more robust, user friendly, and widespread.
Collapse
Affiliation(s)
- Shay Vimer
- Department of Biomolecular Sciences, Weizmann Institute of Science, Rehovot, Israel
| | - Gili Ben-Nissan
- Department of Biomolecular Sciences, Weizmann Institute of Science, Rehovot, Israel
| | - Michal Sharon
- Department of Biomolecular Sciences, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
3
|
Investigation the Possibility of Using Peptides with a Helical Repeating Pattern of Hydro-Phobic and Hydrophilic Residues to Inhibit IL-10. PLoS One 2016; 11:e0153939. [PMID: 27100390 PMCID: PMC4839630 DOI: 10.1371/journal.pone.0153939] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Accepted: 04/06/2016] [Indexed: 01/26/2023] Open
Abstract
Blockade of IL-10 signalling clears chronic viral and bacterial infections. Immunization together with blockade of IL-10 signalling or relatively low level of IL-10 further enhances viral and bacterial clearance. IL-10 functions through binding to interleukin 10 receptor (IL-10R). Here we showed that peptides P1 and P2 with the hydrophobic and hydrophilic pattern of the IL10R-binding helix in IL-10 could bind with either IL-10R1 or IL-10, and inhibit inflammatory signals with long duration and negligible cytotoxicity in vitro. Furthermore, P2 can enhance antigen specific CD8+ T cell responses in mice induced by the vaccine based on a long peptide of protein E7 in a human papillomavirus type 16.
Collapse
|
4
|
Boeri Erba E, Klein PA, Signor L. Combining a NHS ester and glutaraldehyde improves crosslinking prior to MALDI MS analysis of intact protein complexes. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:1114-1119. [PMID: 26456778 DOI: 10.1002/jms.3626] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Revised: 06/11/2015] [Accepted: 06/18/2015] [Indexed: 06/05/2023]
Abstract
Protein complexes play pivotal roles in cellular life. Nevertheless, their characterization remains a substantial challenge. Mass spectrometry (MS) is an emerging tool to study protein assemblies, and electrospray ionization (ESI) is often used because it preserves non-covalent interactions. Matrix-assisted laser desorption/ionization (MALDI) represents an important alternative to ESI because it is more tolerant to salts and detergents (e.g. necessary in the case of membrane complex analyses). Prior to MALDI-MS, the subunits should be crosslinked (XLed). Moreover, crosslinking (XLing) is useful when constraint distances are determined to obtain low-resolution structural information. Here we report a novel XLing approach to study protein complexes with MALDI-MS. We investigated two tetramers (i.e. alcohol dehydrogenase and aldolase) larger than 140 kDa at two pH values (7.2 and 8.0). We tested two different crosslinkers (XLers) (i.e. BS(3) and glutaraldehyde), used separately or in combination. We utilized gentle agitation and ultracentrifugation. Our data shows that the pH influenced the XLing when using a single XLer. Combining two XLers was demonstrated to be more efficient than using a reagent alone. In particular, the combination determined a higher degree of XLing and lower mass shift. This could suggest a ranking in target amino acid availability. First residues at specific distances are linked by BS(3) , then glutaraldehyde binds residues that are still available at larger distances. Ultracentrifugation and gentle agitation both provide similar degrees of XLing, but the former method determined a lower mass increment resulting from redundant XLing. To conclude, we present an efficient dual XLing approach for determining mass and stoichiometry of protein assemblies.
Collapse
Affiliation(s)
- Elisabetta Boeri Erba
- Univ. Grenoble Alpes, IBS, F-38044, Grenoble, France
- CNRS, IBS, F-38044, Grenoble, France
- CEA, IBS, F-38044, Grenoble, France
| | - Pierre Andre Klein
- Univ. Grenoble Alpes, IBS, F-38044, Grenoble, France
- CNRS, IBS, F-38044, Grenoble, France
- CEA, IBS, F-38044, Grenoble, France
| | - Luca Signor
- Univ. Grenoble Alpes, IBS, F-38044, Grenoble, France
- CNRS, IBS, F-38044, Grenoble, France
- CEA, IBS, F-38044, Grenoble, France
| |
Collapse
|
5
|
Boeri Erba E, Petosa C. The emerging role of native mass spectrometry in characterizing the structure and dynamics of macromolecular complexes. Protein Sci 2015; 24:1176-92. [PMID: 25676284 DOI: 10.1002/pro.2661] [Citation(s) in RCA: 90] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Revised: 02/06/2015] [Accepted: 02/06/2015] [Indexed: 12/31/2022]
Abstract
Mass spectrometry (MS) is a powerful tool for determining the mass of biomolecules with high accuracy and sensitivity. MS performed under so-called "native conditions" (native MS) can be used to determine the mass of biomolecules that associate noncovalently. Here we review the application of native MS to the study of protein-ligand interactions and its emerging role in elucidating the structure of macromolecular assemblies, including soluble and membrane protein complexes. Moreover, we discuss strategies aimed at determining the stoichiometry and topology of subunits by inducing partial dissociation of the holo-complex. We also survey recent developments in "native top-down MS", an approach based on Fourier Transform MS, whereby covalent bonds are broken without disrupting non-covalent interactions. Given recent progress, native MS is anticipated to play an increasingly important role for researchers interested in the structure of macromolecular complexes.
Collapse
Affiliation(s)
- Elisabetta Boeri Erba
- Université Grenoble Alpes, Institut de Biologie Structurale (IBS), 71 Avenue des Martyrs, F-38044, Grenoble, France.,Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), DSV, IBS, F-38044, Grenoble, France.,Centre National de la Recherche Scientifique (CNRS), IBS, F-38044, Grenoble, France
| | - Carlo Petosa
- Université Grenoble Alpes, Institut de Biologie Structurale (IBS), 71 Avenue des Martyrs, F-38044, Grenoble, France.,Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), DSV, IBS, F-38044, Grenoble, France.,Centre National de la Recherche Scientifique (CNRS), IBS, F-38044, Grenoble, France
| |
Collapse
|
6
|
Weidmann S, Zenobi R. High-mass MALDI-MS using ion conversion dynode detectors: influence of the conversion voltage on sensitivity and spectral quality. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:950-954. [PMID: 24683015 DOI: 10.1007/s13361-014-0867-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 02/07/2014] [Accepted: 02/07/2014] [Indexed: 06/03/2023]
Abstract
With the development of special ion conversion dynode (ICD) detectors for high-mass matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), the mass-to-charge ratio is no longer a limiting factor. Although these detectors have been successfully used in the past, there is lack of understanding of the basic processes in the detector. We present a systematic study to investigate the performance of such an ICD detector and separate the contributions of the MALDI process from the ones of the ion-to-secondary ion and the secondary ion-to-electron conversions. The performance was evaluated as a function of the voltages applied to the conversion dynodes and the sample amount utilized, and we found that the detector reflects the MALDI process correctly: limitations such as sensitivity or deviations from the expected signal intensity ratios originate from the MALDI process itself and not from the detector.
Collapse
Affiliation(s)
- Simon Weidmann
- Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093, Zürich, Switzerland
| | | |
Collapse
|
7
|
Signor L, Boeri Erba E. Matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometric analysis of intact proteins larger than 100 kDa. J Vis Exp 2013. [PMID: 24056304 PMCID: PMC3857990 DOI: 10.3791/50635] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Effectively determining masses of proteins is critical to many biological studies (e.g. for structural biology investigations). Accurate mass determination allows one to evaluate the correctness of protein primary sequences, the presence of mutations and/or post-translational modifications, the possible protein degradation, the sample homogeneity, and the degree of isotope incorporation in case of labelling (e.g.13C labelling). Electrospray ionisation (ESI) mass spectrometry (MS) is widely used for mass determination of denatured proteins, but its efficiency is affected by the composition of the sample buffer. In particular, the presence of salts, detergents, and contaminants severely undermines the effectiveness of protein analysis by ESI-MS. Matrix-assisted laser desorption/ionization (MALDI) MS is an attractive alternative, due to its salt tolerance and the simplicity of data acquisition and interpretation. Moreover, the mass determination of large heterogeneous proteins (bigger than 100 kDa) is easier by MALDI-MS due to the absence of overlapping high charge state distributions which are present in ESI spectra. Here we present an accessible approach for analysing proteins larger than 100 kDa by MALDI-time of flight (TOF). We illustrate the advantages of using a mixture of two matrices (i.e. 2,5-dihydroxybenzoic acid and α-cyano-4-hydroxycinnamic acid) and the utility of the thin layer method as approach for sample deposition. We also discuss the critical role of the matrix and solvent purity, of the standards used for calibration, of the laser energy, and of the acquisition time. Overall, we provide information necessary to a novice for analysing intact proteins larger than 100 kDa by MALDI-MS.
Collapse
Affiliation(s)
- Luca Signor
- Institute of Structural Biology "J.P. Ebel", UMR5075, Commissariat à L'Energie Atomique et aux Energies Alternatives (CEA), Centre National de la Recherche Scientifique (CNRS), Université J. Fourier
| | | |
Collapse
|
8
|
Weidmann S, Barylyuk K, Nespovitaya N, Mädler S, Zenobi R. A new, modular mass calibrant for high-mass MALDI-MS. Anal Chem 2013; 85:3425-32. [PMID: 23394312 DOI: 10.1021/ac400129h] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The application of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for the analysis of high-mass proteins requires suitable calibration standards at high m/z ratios. Several possible candidates were investigated, and concatenated polyproteins based on recombinantly expressed maltodextrin-binding protein (MBP) are shown here to be well-suited for this purpose. Introduction of two specific recognition sites into the primary sequence of the polyprotein allows for the selective cleavage of MBP3 into MBP and MBP2. Moreover, these MBP2 and MBP3 oligomers can be dimerized specifically, such that generation of MPB4 and MBP6 is possible as well. With the set of calibrants presented here, the m/z range of 40-400 kDa is covered. Since all calibrants consist of the same species and differ only in mass, the ionization efficiency is expected to be similar. However, equimolar mixtures of these proteins did not yield equal signal intensities on a detector specifically designed for detecting high-mass molecules.
Collapse
Affiliation(s)
- Simon Weidmann
- Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, Switzerland
| | | | | | | | | |
Collapse
|