1
|
Wang L, Zhang W, Chen W, He Z, Jia Y, Du J. Cross-Modality Reference and Feature Mutual-Projection for 3D Brain MRI Image Super-Resolution. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024:10.1007/s10278-024-01139-1. [PMID: 38829472 DOI: 10.1007/s10278-024-01139-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 03/30/2024] [Accepted: 04/21/2024] [Indexed: 06/05/2024]
Abstract
High-resolution (HR) magnetic resonance imaging (MRI) can reveal rich anatomical structures for clinical diagnoses. However, due to hardware and signal-to-noise ratio limitations, MRI images are often collected with low resolution (LR) which is not conducive to diagnosing and analyzing clinical diseases. Recently, deep learning super-resolution (SR) methods have demonstrated great potential in enhancing the resolution of MRI images; however, most of them did not take the cross-modality and internal priors of MR seriously, which hinders the SR performance. In this paper, we propose a cross-modality reference and feature mutual-projection (CRFM) method to enhance the spatial resolution of brain MRI images. Specifically, we feed the gradients of HR MRI images from referenced imaging modality into the SR network to transform true clear textures to LR feature maps. Meanwhile, we design a plug-in feature mutual-projection (FMP) method to capture the cross-scale dependency and cross-modality similarity details of MRI images. Finally, we fuse all feature maps with parallel attentions to produce and refine the HR features adaptively. Extensive experiments on MRI images in the image domain and k-space show that our CRFM method outperforms existing state-of-the-art MRI SR methods.
Collapse
Affiliation(s)
- Lulu Wang
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology and Yunnan Key Laboratory of Computer Technologies Application, Kunming, 650500, China.
| | - Wanqi Zhang
- College of Computer Science, Chongqing University, Chongqing, 400044, China
| | - Wei Chen
- College of Computer Science, Chongqing University, Chongqing, 400044, China
| | - Zhongshi He
- College of Computer Science, Chongqing University, Chongqing, 400044, China
| | - Yuanyuan Jia
- Medical Data Science Academy and College of Medical Informatics, Chongqing Medical University, Chongqing, 400016, China
| | - Jinglong Du
- Medical Data Science Academy and College of Medical Informatics, Chongqing Medical University, Chongqing, 400016, China
| |
Collapse
|
2
|
Gimenez U, Deloulme JC, Lahrech H. Rapid microscopic 3D-diffusion tensor imaging fiber-tracking of mouse brain in vivo by super resolution reconstruction: validation on MAP6-KO mouse model. MAGMA (NEW YORK, N.Y.) 2023; 36:577-587. [PMID: 36695926 DOI: 10.1007/s10334-023-01061-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Revised: 12/10/2022] [Accepted: 01/10/2023] [Indexed: 01/26/2023]
Abstract
OBJECT Exploring mouse brains by rapid 3D-Diffusion Tensor Imaging (3D-DTI) of high spatial resolution (HSR) is challenging in vivo. Here we use the super resolution reconstruction (SRR) postprocessing method to demonstrate its performance on Microtubule-Associated-Protein6 Knock-Out (MAP6-KO) mice. MATERIALS AND METHODS Two spin-echo DTI were acquired (9.4T, CryoProbe RF-coil): (i)-multislice 2D-DTI, (echo-planar integrating reversed-gradient) acquired in vivo in the three orthogonal orientations (360 μm slice-thickness, 120 × 120 μm in-plane resolution, 56 min scan duration); used in SRR software to reconstruct SRR 3D-DTI with HSR in slice-plane (120 × 120 × 120 µm) and (ii)-microscopic 3D-DTI (µ-3D-DTI), (100 × 100 × 100 µm; 8 h 6 min) on fixed-brains ex vivo, that were removed after paramagnetic contrast-agent injection to accelerate scan acquisition using short repetition-times without NMR-signal sensitivity loss. RESULTS White-matter defects, quantified from both 3D-DTI fiber-tracking were found very similar. Indeed, as expected the fornix and cerebral-peduncle volume losses were - 39% and - 35% in vivo (SRR 3D-DTI) versus - 34% and - 32% ex vivo (µ-3D-DTI), respectively (p<0.001). This finding is robust since the µ-3D-DTI feasibility on MAP6-KO ex vivo was already validated by fluorescent-microscopy of cleared brains. DISCUSSION First performance of the SRR to generate rapid HSR 3D-DTI of mouse brains in vivo is demonstrated. The method is suitable in neurosciences for longitudinal studies to identify molecular and genetic abnormalities in mouse models that are of growing developments.
Collapse
Affiliation(s)
- Ulysse Gimenez
- University. Grenoble Alpes, Inserm, U1205, BrainTech Lab, 1, place Commandant Nal, 38700, La Tronche, Grenoble, France
- , BioSerenity company 20 Rue Berbier de Mets, 75013, Paris, France
| | - Jean Christophe Deloulme
- University. Grenoble Alpes, Inserm, U1216, CEA, Grenoble Institut Neurosciences, 31, chemin Fortuné Ferrini, 38700, La Tronche, Grenoble, France
| | - Hana Lahrech
- University. Grenoble Alpes, Inserm, U1205, BrainTech Lab, 1, place Commandant Nal, 38700, La Tronche, Grenoble, France.
| |
Collapse
|
3
|
Sui Y, Afacan O, Jaimes C, Gholipour A, Warfield SK. Scan-Specific Generative Neural Network for MRI Super-Resolution Reconstruction. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:1383-1399. [PMID: 35020591 PMCID: PMC9208763 DOI: 10.1109/tmi.2022.3142610] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The interpretation and analysis of Magnetic resonance imaging (MRI) benefit from high spatial resolution. Unfortunately, direct acquisition of high spatial resolution MRI is time-consuming and costly, which increases the potential for motion artifact, and suffers from reduced signal-to-noise ratio (SNR). Super-resolution reconstruction (SRR) is one of the most widely used methods in MRI since it allows for the trade-off between high spatial resolution, high SNR, and reduced scan times. Deep learning has emerged for improved SRR as compared to conventional methods. However, current deep learning-based SRR methods require large-scale training datasets of high-resolution images, which are practically difficult to obtain at a suitable SNR. We sought to develop a methodology that allows for dataset-free deep learning-based SRR, through which to construct images with higher spatial resolution and of higher SNR than can be practically obtained by direct Fourier encoding. We developed a dataset-free learning method that leverages a generative neural network trained for each specific scan or set of scans, which in turn, allows for SRR tailored to the individual patient. With the SRR from three short duration scans, we achieved high quality brain MRI at an isotropic spatial resolution of 0.125 cubic mm with six minutes of imaging time for T2 contrast and an average increase of 7.2 dB (34.2%) in SNR to these short duration scans. Motion compensation was achieved by aligning the three short duration scans together. We assessed our technique on simulated MRI data and clinical data acquired from 15 subjects. Extensive experimental results demonstrate that our approach achieved superior results to state-of-the-art methods, while in parallel, performed at reduced cost as scans delivered with direct high-resolution acquisition.
Collapse
|
4
|
Sui Y, Afacan O, Jaimes C, Gholipour A, Warfield SK. Gradient-Guided Isotropic MRI Reconstruction from Anisotropic Acquisitions. IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING 2021; 7:1240-1253. [PMID: 35252479 PMCID: PMC8896514 DOI: 10.1109/tci.2021.3128745] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The trade-off between image resolution, signal-to-noise ratio (SNR), and scan time in any magnetic resonance imaging (MRI) protocol is inevitable and unavoidable. Super-resolution reconstruction (SRR) has been shown effective in mitigating these factors, and thus, has become an important approach in addressing the current limitations of MRI. In this work, we developed a novel, image-based MRI SRR approach based on anisotropic acquisition schemes, which utilizes a new gradient guidance regularization method that guides the high-resolution (HR) reconstruction via a spatial gradient estimate. Further, we designed an analytical solution to propagate the spatial gradient fields from the low-resolution (LR) images to the HR image space and exploited these gradient fields over multiple scales with a dynamic update scheme for more accurate edge localization in the reconstruction. We also established a forward model of image formation and inverted it along with the proposed gradient guidance. The proposed SRR method allows subject motion between volumes and is able to incorporate various acquisition schemes where the LR images are acquired with arbitrary orientations and displacements, such as orthogonal and through-plane origin-shifted scans. We assessed our proposed approach on simulated data as well as on the data acquired on a Siemens 3T MRI scanner containing 45 MRI scans from 14 subjects. Our experimental results demonstrate that our approach achieved superior reconstructions compared to state-of-the-art methods, both in terms of local spatial smoothness and edge preservation, while, in parallel, at reduced, or at the same cost as scans delivered with direct HR acquisition.
Collapse
Affiliation(s)
- Yao Sui
- Harvard Medical School and Boston Children's Hospital, Boston, Massachusetts, United States
| | - Onur Afacan
- Harvard Medical School and Boston Children's Hospital, Boston, Massachusetts, United States
| | - Camilo Jaimes
- Harvard Medical School and Boston Children's Hospital, Boston, Massachusetts, United States
| | - Ali Gholipour
- Harvard Medical School and Boston Children's Hospital, Boston, Massachusetts, United States
| | - Simon K Warfield
- Harvard Medical School and Boston Children's Hospital, Boston, Massachusetts, United States
| |
Collapse
|
5
|
MRI Super-Resolution Through Generative Degradation Learning. ACTA ACUST UNITED AC 2021; 12906:430-440. [PMID: 34713277 DOI: 10.1007/978-3-030-87231-1_42] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
Abstract
Spatial resolution plays a critically important role in MRI for the precise delineation of the imaged tissues. Unfortunately, acquisitions with high spatial resolution require increased imaging time, which increases the potential of subject motion, and suffers from reduced signal-to-noise ratio (SNR). Super-resolution reconstruction (SRR) has recently emerged as a technique that allows for a trade-off between high spatial resolution, high SNR, and short scan duration. Deconvolution-based SRR has recently received significant interest due to the convenience of using the image space. The most critical factor to succeed in deconvolution is the accuracy of the estimated blur kernels that characterize how the image was degraded in the acquisition process. Current methods use handcrafted filters, such as Gaussian filters, to approximate the blur kernels, and have achieved promising SRR results. As the image degradation is complex and varies with different sequences and scanners, handcrafted filters, unfortunately, do not necessarily ensure the success of the deconvolution. We sought to develop a technique that enables accurately estimating blur kernels from the image data itself. We designed a deep architecture that utilizes an adversarial scheme with a generative neural network against its degradation counterparts. This design allows for the SRR tailored to an individual subject, as the training requires the scan-specific data only, i.e., it does not require auxiliary datasets of high-quality images, which are practically challenging to obtain. With this technique, we achieved high-quality brain MRI at an isotropic resolution of 0.125 cubic mm with six minutes of imaging time. Extensive experiments on both simulated low-resolution data and clinical data acquired from ten pediatric patients demonstrated that our approach achieved superior SRR results as compared to state-of-the-art deconvolution-based methods, while in parallel, at substantially reduced imaging time in comparison to direct high-resolution acquisitions.
Collapse
|
6
|
Sui Y, Afacan O, Gholipour A, Warfield SK. Fast and High-Resolution Neonatal Brain MRI Through Super-Resolution Reconstruction From Acquisitions With Variable Slice Selection Direction. Front Neurosci 2021; 15:636268. [PMID: 34220414 PMCID: PMC8242183 DOI: 10.3389/fnins.2021.636268] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 05/19/2021] [Indexed: 12/18/2022] Open
Abstract
The brain of neonates is small in comparison to adults. Imaging at typical resolutions such as one cubic mm incurs more partial voluming artifacts in a neonate than in an adult. The interpretation and analysis of MRI of the neonatal brain benefit from a reduction in partial volume averaging that can be achieved with high spatial resolution. Unfortunately, direct acquisition of high spatial resolution MRI is slow, which increases the potential for motion artifact, and suffers from reduced signal-to-noise ratio. The purpose of this study is thus that using super-resolution reconstruction in conjunction with fast imaging protocols to construct neonatal brain MRI images at a suitable signal-to-noise ratio and with higher spatial resolution than can be practically obtained by direct Fourier encoding. We achieved high quality brain MRI at a spatial resolution of isotropic 0.4 mm with 6 min of imaging time, using super-resolution reconstruction from three short duration scans with variable directions of slice selection. Motion compensation was achieved by aligning the three short duration scans together. We applied this technique to 20 newborns and assessed the quality of the images we reconstructed. Experiments show that our approach to super-resolution reconstruction achieved considerable improvement in spatial resolution and signal-to-noise ratio, while, in parallel, substantially reduced scan times, as compared to direct high-resolution acquisitions. The experimental results demonstrate that our approach allowed for fast and high-quality neonatal brain MRI for both scientific research and clinical studies.
Collapse
Affiliation(s)
- Yao Sui
- Computational Radiology Laboratory, Department of Radiology, Boston Children's Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
| | - Onur Afacan
- Computational Radiology Laboratory, Department of Radiology, Boston Children's Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
| | - Ali Gholipour
- Computational Radiology Laboratory, Department of Radiology, Boston Children's Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
| | - Simon K. Warfield
- Computational Radiology Laboratory, Department of Radiology, Boston Children's Hospital, Boston, MA, United States
- Harvard Medical School, Boston, MA, United States
| |
Collapse
|