Zopfs D, Lennartz S, Pennig L, Glauner A, Abdullayev N, Bremm J, Große Hokamp N, Persigehl T, Kabbasch C, Borggrefe J, Laukamp KR. Virtual monoenergetic images and post-processing algorithms effectively reduce CT artifacts from intracranial aneurysm treatment. Sci Rep 2020; 10:6629. [PMID: 32313094 PMCID: PMC7170914 DOI: 10.1038/s41598-020-63574-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 04/01/2020] [Indexed: 11/09/2022] Open
Abstract
To evaluate artifact reduction by virtual monoenergetic images (VMI) and metal artifact reduction algorithms (MAR) as well as the combination of both approaches (VMIMAR) compared to conventional CT images (CI) as standard of reference. In this retrospective study, 35 patients were included who underwent spectral-detector CT (SDCT) with additional MAR-reconstructions due to artifacts from coils or clips. CI, VMI, MAR and VMIMAR (range: 100-200 keV, 10 keV-increment) were reconstructed. Region-of-interest based objective analysis was performed by assessing mean and standard deviation of attenuation (HU) in hypo- and hyperdense artifacts from coils and clips. Visually, extent of artifact reduction and diagnostic assessment were rated. Compared to CI, VMI ≥ 100 keV, MAR and VMIMAR between 100-200 keV increased attenuation in hypoattenuating artifacts (CI/VMI200keV/MAR/VMIMAR200keV, HU: -77.6 ± 81.1/-65.1 ± 103.2/-36.9 ± 27.7/-21.1 ± 26.7) and decreased attenuation in hyperattenuating artifacts (HU: 47.4 ± 32.3/42.1 ± 50.2/29.5 ± 18.9/20.8 ± 25.8). However, differences were only significant for MAR in hypodense and VMIMAR in hypo- and hyperdense artifacts (p < 0.05). Visually, hypo- and hyperdense artifacts were significantly reduced compared to CI by VMI≥140/100keV, MAR and VMIMAR≥100keV. Diagnostic assessment of surrounding brain tissue was significantly improved in VMI≥100keV, MAR and VMIMAR≥100keV. The combination of VMI and MAR facilitates a significant reduction of artifacts adjacent to intracranial coils and clips. Hence, if available, these techniques should be combined for optimal reduction of artifacts following intracranial aneurysm treatment.
Collapse
Affiliation(s)
- David Zopfs
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Simon Lennartz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.,Else Kröner Forschungskolleg Clonal Evolution in Cancer, University Hospital Cologne, Weyertal 115b, 50931, Cologne, Germany
| | - Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Andreas Glauner
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Nuran Abdullayev
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Johannes Bremm
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Nils Große Hokamp
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Thorsten Persigehl
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Christoph Kabbasch
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Jan Borggrefe
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Kai Roman Laukamp
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany. .,University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA. .,Case Western Reserve University, Department of Radiology, Cleveland, OH, USA.
| |
Collapse
|
2
|
Winklhofer S, Hinzpeter R, Stocker D, Baltsavias G, Michels L, Burkhardt JK, Regli L, Valavanis A, Alkadhi H. Combining monoenergetic extrapolations from dual-energy CT with iterative reconstructions: reduction of coil and clip artifacts from intracranial aneurysm therapy. Neuroradiology 2018; 60:281-291. [DOI: 10.1007/s00234-018-1981-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Accepted: 01/10/2018] [Indexed: 10/18/2022]
|
3
|
Jia Y, Zhang J, Fan J, Li C, Sun Y, Li D, Xiao X. Gemstone spectral imaging reduced artefacts from metal coils or clips after treatment of cerebral aneurysms: a retrospective study of 35 patients. Br J Radiol 2015; 88:20150222. [PMID: 26329465 PMCID: PMC4743447 DOI: 10.1259/bjr.20150222] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Revised: 08/19/2015] [Accepted: 09/01/2015] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE This study aimed to evaluate the effect of gemstone spectral imaging (GSI) for metal artefact reduction in cerebral artery CT angiography (CTA) after metal coils or clips treatment. METHODS 35 patients with cerebral aneurysms were treated with metal coils or clips and underwent CTA using gemstone spectral CT between February and December 2013. The data were reconstructed into three image groups including Group A (quality check images with 140 kVp), Group B (monochromatic image sets in the range of 40-140 keV) and Group C [monochromatic image sets with metal artefacts reduction software (MARS GE Medical Systems, Waukesha, WI)]. CT attenuation value of cerebral artery, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and the subjective score of all images were measured and compared statistically. RESULTS CT attenuation value of cerebral artery decreased in Groups B and C as the photon energy increased. The average energy levels of 60.05 ± 5.37 and 59.93 ± 5.57 keV presented the best CNR in Groups B and C, respectively. CNR values, SNR values and the subjective scores of the image quality of the two sets were higher than those of Group A. CONCLUSION GSI reduced metal artefact and improved the image quality of CTA after metal coils or clips treatment in patients with cerebral aneurysm. The monochromatic images at the average energy level of 60.05 ± 5.37 keV with MARS and 59.93 ± 5.57 keV without MARS were suggested to be the optimal parameters. ADVANCES IN KNOWLEDGE GSI could reduce metal artefact after metal coils or clips treatment in patients with cerebral aneurysm.
Collapse
Affiliation(s)
- Yulin Jia
- Department of CT, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Jinling Zhang
- Department of CT, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Jinyu Fan
- Department of CT, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Chao Li
- Department of Medical Imaging, Heilongjiang Provincial Hospital, Harbin, China
| | - Yuanyuan Sun
- Department of CT, The First Hospital of Harbin, Harbin, China
| | - Di Li
- Department of CT, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Xigang Xiao
- Department of CT, The First Affiliated Hospital of Harbin Medical University, Harbin, China
| |
Collapse
|
4
|
Ott S, Gölitz P, Adamek E, Royalty K, Doerfler A, Struffert T. Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study. Interv Neuroradiol 2015; 21:490-8. [PMID: 26111985 DOI: 10.1177/1591019915590364] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both.In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality.In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p < 0.05). The diameter of stents was identical for DSA and FD-CTA and was significantly overestimated in MS-CTA (p < 0.05). Beam/metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA.MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting.
Collapse
Affiliation(s)
- Sabine Ott
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Philipp Gölitz
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Edyta Adamek
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Kevin Royalty
- Department of Biomedical Engineering and School of Medicine and Public Health, University of Wisconsin, USA
| | - Arnd Doerfler
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| | - Tobias Struffert
- Department of Neuroradiology, University of Erlangen-Nuremberg, Germany
| |
Collapse
|