1
|
Shibutani T, Okuda K, Ichikawa H, Kato T, Miwa K, Tsushima H, Onoguchi M, Nagaki A. Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan. Jpn J Radiol 2020; 38:274-282. [PMID: 31919636 DOI: 10.1007/s11604-019-00915-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 12/20/2019] [Indexed: 11/24/2022]
Abstract
AIM Recently, nuclear cardiology has dramatically advanced by a new technology development such as the device, short-term acquisition system, image reconstruction algorithm and image analysis. Although these innovations have been gradually employed in routine examinations, we did not investigate the current use of image acquisition, image reconstruction, and image analysis with myocardial perfusion single-photon emission computed tomography (MPS). We investigated the current status of MPS imaging technology in Japan. METHODS We carried out a survey using a Web-based questionnaire system, the opening of which was announced via e-mail, and it was available on a website for 3 months. We collected data on the current use of MPS with 201Tl and/or 99mTc agents with respect to routine protocols, image acquisition, image reconstruction, and image analysis. RESULTS We received responses to the Web-based questionnaire from 178 and 174 people for 99mTc and 201Tl MPS, respectively. The routine protocols of MPS of stress-rest and rest-stress MPS on 1-day protocols with 99mTc were 41.2% and 14.5%, respectively, and the rest-only scan response rate was 23.7%, whereas that of 201Tl MPS was 65.9% with stress-rest MPS, 19.0% with rest-only MPS, and 10.9% with stress-rest MPS adding a rest scan 24 h after injection. The filtered back projection (FBP) method is most commonly used image reconstruction method, yielding 70.5% for 99mTc MPS and 76.8% for 201Tl MPS, including combined FBP and ordered subset expectation maximization method. The results for no-correction (NC) images were 49.2% with 99mTc MPS and 55.2% with 201Tl MPS including the response of NC and combined attenuation correction (AC) and scatter correction (SC) (i.e., ACSC) images. The AC or ACSC images of 99mTc and 201Tl were provided by 30-40% of the institutions surveyed. CONCLUSIONS We investigated the current status of MPS imaging technology in Japan, and found that although the use of various technical developments has been reported, some of these technologies have not been utilized effectively. Hence, we expect that nuclear medicine technology will be used more effectively to improve diagnosis.
Collapse
Affiliation(s)
- Takayuki Shibutani
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80, Kodatsuno, Kanazawa, Ishikawa, Japan.
| | - Koichi Okuda
- Department of Physics, Kanazawa Medical University, Kahoku, Japan
| | - Hajime Ichikawa
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, Japan
| | - Toyohiro Kato
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, Japan
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, International University of Health and Welfare, Ohtawara, Japan
| | - Hiroyuki Tsushima
- Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, Ibaraki, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80, Kodatsuno, Kanazawa, Ishikawa, Japan
| | - Akio Nagaki
- Department of Radiological Technology, Kurashiki Central Hospital, Kurashiki, Japan
| |
Collapse
|
2
|
Sakr TM, Ibrahim AB, Fasih TW, Rashed HM. Preparation and biological profile of 99mTc-lidocaine as a cardioselective imaging agent using 99mTc eluted from 99Mo/99mTc generator based on Al–Mo gel. J Radioanal Nucl Chem 2017. [DOI: 10.1007/s10967-017-5560-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
3
|
Shibutani T, Onoguchi M, Yoneyama H, Konishi T, Matsuo S, Nakajima K, Kinuya S. Characteristics of single- and dual-photopeak energy window acquisitions with thallium-201 IQ-SPECT/CT system. Ann Nucl Med 2017; 31:529-535. [PMID: 28470630 DOI: 10.1007/s12149-017-1177-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Accepted: 04/25/2017] [Indexed: 10/19/2022]
|
4
|
Misaka T, Hosono M, Kudo T, Ito T, Syomura T, Uemura M, Okajima K. Influence of acquisition orbit on phase analysis of gated single photon emission computed tomography myocardial perfusion imaging for assessment of left ventricular mechanical dyssynchrony. Ann Nucl Med 2017; 31:235-244. [PMID: 28144811 DOI: 10.1007/s12149-017-1151-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Accepted: 01/10/2017] [Indexed: 12/01/2022]
Abstract
OBJECTIVE The association between left ventricular (LV) dyssynchrony parameters, given by phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), and acquisition orbits is unclear. The aim of this study was to assess the dependence of LV dyssynchrony parameters on acquisition orbits. METHODS Ninety-nine patients who underwent 201Tl-gated SPECT MPI were categorized into minor hypoperfusion or major hypoperfusion groups. Forty-four patients who underwent 99mTc-tetrofosmin-gated SPECT MPI were categorized into minor hypoperfusion or major hypoperfusion groups. The major hypoperfusion group with 201Tl was divided into inferior or non-inferior wall hypoperfusion subgroups, and anteroseptal or non-anteroseptal wall hypoperfusion subgroups. Gated SPECT MPI data over a 360° acquisition orbit (360° images) and a 180° acquisition orbit (180° images) were reconstructed, and histogram bandwidth (HBW) and phase standard deviation (PSD) were compared. RESULTS Between 360° and 180° images with 201Tl, there were significant differences in HBW and PSD both globally (HBW 34.8 ± 16.6 vs. 29.1 ± 10.2; PSD 8.8 ± 4.9 vs. 7.0 ± 2.3, p < 0.05 for both) and in the inferior wall (HBW 29.5 ± 15.5 vs. 23.3 ± 9.0; PSD 7.6 ± 4.6 vs. 5.6 ± 2.4, p < 0.001 for both) in the major hypoperfusion group, and also in the inferior wall in all subgroups of the major hypoperfusion group. In contrast, no segment had any significant differences in HBW or PSD between 360° and 180° images with 99mTc. CONCLUSION Differences in acquisition orbit had a significant influence on HBW and PSD with 201Tl-gated SPECT MPI in the inferior wall in patients with major hypoperfusion myocardium.
Collapse
Affiliation(s)
- Tomofumi Misaka
- Department of Radiology, Kindai University Nara Hospital, 1248-1, Otoda-cho, Ikoma, Nara, Japan
| | - Makoto Hosono
- Faculty of Medicine, Institute of Advanced Clinical Medicine, Kindai University, 377-2, Ohno-Higashi, Osaka-Sayama, Osaka, 589-8511, Japan.
| | - Takashi Kudo
- Department of Radioisotope Medicine, Atomic Bomb Disease Institute, Nagasaki University, 1-12-4, Sakamoto, Nagasaki, Nagasaki, Japan
| | - Takamichi Ito
- Department of Radiology, Kindai University Nara Hospital, 1248-1, Otoda-cho, Ikoma, Nara, Japan
| | - Tsutomu Syomura
- Department of Radiology, Kindai University Nara Hospital, 1248-1, Otoda-cho, Ikoma, Nara, Japan
| | - Masanobu Uemura
- Department of Radiology, Kindai University Nara Hospital, 1248-1, Otoda-cho, Ikoma, Nara, Japan
| | - Kaoru Okajima
- Department of Radiology, Kindai University Nara Hospital, 1248-1, Otoda-cho, Ikoma, Nara, Japan
| |
Collapse
|
5
|
Yang H, Bathaii M, Houseni M, El-Haddad G, Zhuang H, Alavi A, Araujo L. False-positive reversible septal myocardial perfusion defect caused by diaphragmatic hernia. Clin Nucl Med 2007; 32:231-3. [PMID: 17314607 DOI: 10.1097/01.rlu.0000255223.50040.59] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- Hua Yang
- Department of Radiology, University of Pennsylvania School of Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | | | | | | | | | | | | |
Collapse
|
6
|
Saghari M, Assadi M, Eftekhari M, Yaghoubi M, Fard-Esfahani A, Malekzadeh JM, Sichani BF, Beiki D, Takavar A. Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X. BMC NUCLEAR MEDICINE 2006; 6:1. [PMID: 16503964 PMCID: PMC1402267 DOI: 10.1186/1471-2385-6-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2005] [Accepted: 02/17/2006] [Indexed: 11/17/2022]
Abstract
Background Cardiac syndrome X is defined by a typical angina pectoris with normal or near normal (stenosis <40%) coronary angiogram with or without electrocardiogram (ECG) change or atypical angina pectoris with normal or near normal coronary angiogram plus a positive none-invasive test (exercise tolerance test or myocardial perfusion scan) with or without ECG change. Studies with myocardial perfusion imaging on this syndrome have indicated some abnormal perfusion scan. We evaluated the role of myocardial perfusion imaging (MPI) and also the severity and extent of perfusion abnormality using Tc-99m MIBI Single Photon Emission Computed Tomography (SPECT) in these patients. Methods The study group consisted of 36 patients with cardiac syndrome X. The semiquantitative perfusion analysis was performed using exercise Tc-99m MIBI SPECT. The MPI results were analyzed by the number, location and severity of perfusion defects. Results Abnormal perfusion defects were detected in 13 (36.10%) cases, while the remaining 23 (63.90%) had normal cardiac imaging. Five of 13 (38.4%) abnormal studies showed multiple perfusion defects. The defects were localized in the apex in 3, apical segments in 4, midventricular segments in 12 and basal segments in 6 cases. Fourteen (56%) of all abnormal segments revealed mild, 7(28%) moderate and 4 (16%) severe reduction of tracer uptake. No fixed defects were identified. The vessel territories were approximately the same in all subjects. The Exercise treadmill test (ETT) was positive in 25(69%) and negative in 11(30%) patients. There was no consistent pattern as related to the extent of MPI defects or exercise test results. Conclusion Our study suggests that multiple perfusion abnormalities with different levels of severity are common in cardiac syndrome X, with more than 30 % of these patients having at least one abnormal perfusion segment. Our findings suggest that in these patients microvascular angina is probably more common than is generally believed.
Collapse
Affiliation(s)
- Mohsen Saghari
- Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Shariati Hospital, North Kargar Ave. 14114, Tehran, Iran
| | - Majid Assadi
- Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Shariati Hospital, North Kargar Ave. 14114, Tehran, Iran
| | - Mohammad Eftekhari
- Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Shariati Hospital, North Kargar Ave. 14114, Tehran, Iran
| | - Mohammad Yaghoubi
- Department of Cardiology, Shariati Hospital, Faculty of Medicine, Tehran University of Medical Sciences, North Kargar Ave. 14114, Tehran, Iran
| | - Armaghan Fard-Esfahani
- Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Shariati Hospital, North Kargar Ave. 14114, Tehran, Iran
| | - Jan-Mohammad Malekzadeh
- Department of Cardiology, Shariati Hospital, Faculty of Medicine, Tehran University of Medical Sciences, North Kargar Ave. 14114, Tehran, Iran
| | - Babak Fallhi Sichani
- Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Shariati Hospital, North Kargar Ave. 14114, Tehran, Iran
| | - Davood Beiki
- Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Shariati Hospital, North Kargar Ave. 14114, Tehran, Iran
| | - Abbas Takavar
- Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Shariati Hospital, North Kargar Ave. 14114, Tehran, Iran
| |
Collapse
|
7
|
Hsu HB, Shiau YC, Kao A, Lin CC, Lee CC. Technetium-99m tetrofosmin myocardial perfusion single photon emission computed tomography in syndrome X: a preliminary report. JAPANESE HEART JOURNAL 2003; 44:153-62. [PMID: 12718478 DOI: 10.1536/jhj.44.153] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Syndrome X is used to describe patients with chest pain and a normal coronary angiogram. We reviewed technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion single photon emission computed tomography (SPECT) results and clinical data of 43 syndrome X patients and 30 healthy controls with normal left ventricular ejection fraction and no cardiac abnormalities. The Tc-99m TF myocardial perfusion SPECT results showed 12 (27.9%) syndrome X patients had normal myocardial perfusion and 31 (72.1%) had abnormal myocardial perfusion, including 6 (14.0%) patients with fixed defects. 20 (46.5%) patients with transient defects, and 5 (11.6%) patients with reverse defects. The results of exercise ECG were not related to perfusion defects in Tc-99m TF myocardial perfusion SPECT. In contrast, all of the 30 (100.0%) healthy controls had normal myocardial perfusion SPECT results. We conclude that abnormal Tc-99m TF myocardial perfusion SPECT is common in syndrome X and does not correlate well with the exercise ECG. However, further studies with larger case numbers and long term follow up in patients with myocardial events are necessary to support our findings.
Collapse
Affiliation(s)
- Hsiu-Bao Hsu
- Division of Cardiology, China Medical College Hospital, Taichung, Taiwan
| | | | | | | | | |
Collapse
|
8
|
Choi JY, Lee KH, Kim SJ, Kim SE, Kim BT, Lee SH, Lee WR. Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT. J Nucl Cardiol 1998; 5:395-401. [PMID: 9715984 DOI: 10.1016/s1071-3581(98)90145-3] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND Because equivocal fixed perfusion defects on single photon emission computed tomography (SPECT) often cause a diagnostic dilemma in patients with suspected coronary artery disease (CAD), we used receiver-operating characteristic (ROC) curve analysis to evaluate the degree of increased accuracy provided by adding gated images for interpretation of such cases. METHODS AND RESULTS One hundred five (29%) of 365 consecutive patients undergoing technetium 99m tetrofosmin gated SPECT for evaluation of CAD demonstrated an equivocal fixed defect. Two independent observers graded the probability for true lesion with a 5-point system over 3 steps of interpretation: reviewing tomographic images alone (step 1), adding projection images (step 2), and adding gated cine images (step 3). Based on clinical criteria, 66 patients were categorized as disease negative and 25 as disease positive, while the final diagnosis was undetermined in 14 cases. Diagnostic performance was significantly higher at step 3 than at step 1 for both observers (p < 0.05 and < 0.0001) and at step 2 for observer B (p < 0.005). The maximum accuracy increased from 78.0% to 80.2% at step 2 to 84.6% to 86.8% at step 3. Moreover, the agreement of interpretation between the 2 observers was higher at step 3 (kappa = 0.53) than at step 1 (kappa = 0.29) or step 2 (kappa = 0.25). CONCLUSION In patients showing an equivocal fixed defect on 99mTc tetrofosmin SPECT, gated cine images provide improved differential accuracy and enhanced objectivity of interpretation by reducing interobserver variance.
Collapse
Affiliation(s)
- J Y Choi
- Department of Nuclear Medicine and Cardiovascular Institute, Sung Kyun Kwan University College of Medicine, Samsung Medical Center, Seoul, Korea
| | | | | | | | | | | | | |
Collapse
|
9
|
Abstract
The authors reviewed the stress Tc-99m MIBI SPECT results and clinical data of 15 patients with syndrome X. The results of exercise EKG and resting left ventricular ejection fraction (LVEF) were compared with the results of Tc-99m MIBI SPECT. Of the 15 patients, 9 (60%) had a normal Tc-99m MIBI SPECT study and 6 (40%) had an abnormal Tc-99m MIBI SPECT. The authors found that 1) an abnormal Tc-99m MIBI SPECT was common in syndrome X, 2) the results of the exercise EKG were not related to perfusion defects on Tc-99m MIBI SPECT, and 3) for patients with an abnormal Tc-99m MIBI SPECT, the incidence of an abnormal resting LVEF and cardiac abnormalities were not higher than in patients with normal Tc-99m MIBI SPECT studies.
Collapse
Affiliation(s)
- C H Kao
- Department of Nuclear Medicine, Taichung Veterans General Hospital, Taiwan, Republic of China
| | | | | | | |
Collapse
|
10
|
Stiens SA, Johnson MC, Lyman PJ. Cardiac Rehabilitation in Patients with Spinal Cord Injuries. Phys Med Rehabil Clin N Am 1995. [DOI: 10.1016/s1047-9651(18)30466-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|