• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4599786)   Today's Articles (3822)   Subscriber (49360)
For: Scheper T. Biosensors for process monitoring. ACTA ACUST UNITED AC 1992;9:163-72. [PMID: 1368367 DOI: 10.1007/bf01569620] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Number Cited by Other Article(s)
1
Guler E, Soyleyici HC, Demirkol DO, Ak M, Timur S. A novel functional conducting polymer as an immobilization platform. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014;40:148-56. [DOI: 10.1016/j.msec.2014.03.063] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2013] [Revised: 02/18/2014] [Accepted: 03/22/2014] [Indexed: 11/24/2022]
2
Akin M, Yuksel M, Geyik C, Odaci D, Bluma A, Höpfner T, Beutel S, Scheper T, Timur S. Alcohol biosensing by polyamidoamine (PAMAM)/cysteamine/alcohol oxidase-modified gold electrode. Biotechnol Prog 2010;26:896-906. [DOI: 10.1002/btpr.372] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
3
Glindkamp A, Riechers D, Rehbock C, Hitzmann B, Scheper T, Reardon KF. Sensors in Disposable Bioreactors Status and Trends. DISPOSABLE BIOREACTORS 2009;115:145-69. [DOI: 10.1007/10_2009_10] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
4
Polzius R, Bier FF, Bilitewski U, Jäger V, Schmid RD. On-line monitoring of monoclonal antibodies in animal cell culture using a grating coupler. Biotechnol Bioeng 2004;42:1287-92. [DOI: 10.1002/bit.260421105] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
5
Covalent immobilisation of invertase onto a reactive film composed of 2-hydroxyethyl methacrylate and glycidyl methacrylate: properties and application in a continuous flow system. Biochem Eng J 2003. [DOI: 10.1016/s1369-703x(02)00170-5] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
6
Gouda MD, Kumar MA, Thakur MS, Karanth NG. Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents. Biosens Bioelectron 2002;17:503-7. [PMID: 11959471 DOI: 10.1016/s0956-5663(02)00021-0] [Citation(s) in RCA: 90] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
7
Yarnitzky CN, Campbell CN, Caruana AM, Georgiou G, Heller A, Vreeke MS. Part II. Potentiodynamic on-line monitoring of the concentration of glucose in metal-walled bioreactors. J Electroanal Chem (Lausanne) 2000. [DOI: 10.1016/s0022-0728(00)00165-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
8
Puchades R, Maquieira A. Recent Developments in Flow Injection Immunoanalysis. Crit Rev Anal Chem 1996. [DOI: 10.1080/10408349608050574] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
9
Baxter PJ, Christian GD. Sequential Injection Analysis:  A Versatile Technique for Bioprocess Monitoring. Acc Chem Res 1996. [DOI: 10.1021/ar950214z] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
10
Biosensors in bioprocess monitoring. J Chromatogr A 1996. [DOI: 10.1016/0021-9673(95)00998-1] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
11
Heitzer A, Malachowsky K, Thonnard JE, Bienkowski PR, White DC, Sayler GS. Optical biosensor for environmental on-line monitoring of naphthalene and salicylate bioavailability with an immobilized bioluminescent catabolic reporter bacterium. Appl Environ Microbiol 1994;60:1487-94. [PMID: 8017932 PMCID: PMC201507 DOI: 10.1128/aem.60.5.1487-1494.1994] [Citation(s) in RCA: 196] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]  Open
12
Gebbert A, Alvarez-Icaza M, Peters H, Jäger V, Bilitewski U, Schmid RD. On-line monitoring of monoclonal antibody production with regenerable flow-injection immuno systems. J Biotechnol 1994;32:213-20. [PMID: 7764714 DOI: 10.1016/0168-1656(94)90207-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
13
Freitag R. Applied biosensors. Curr Opin Biotechnol 1993;4:75-9. [PMID: 7763398 DOI: 10.1016/0958-1669(93)90036-v] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA