Mrochen M, Schelling U, Wuellner C, Donitzky C. Influence of spatial and temporal spot distribution on the ocular surface quality and maximum ablation depth after photoablation with a 1050 Hz excimer laser system. J Cataract Refract Surg 2009; 35:363-73. [DOI: 10.1016/j.jcrs.2008.10.053] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2008] [Revised: 10/08/2008] [Accepted: 10/28/2008] [Indexed: 11/26/2022]
|
2
|
Abstract
PURPOSE To assess intraoperative complications and long-term outcome of elliptical excimer laser trephination for penetrating keratoplasties (EELPKs) performed at the Friedrich-Alexander University of Erlangen, between 1989 and 2002. METHODS This was a retrospective, longitudinal, single-center, clinical, interventional case series. Forty-two eyes (14 Fuchs dystrophy, 11 corneal ulcer, 7 aphakic/pseudophakic bullous keratopathy, 9 corneal scars, 1 keratotorus) after EELPK were observed. Trephination was performed with a 193-nm Meditec excimer laser along metal masks with 0-8 orientation teeth/notches. Horizontal/vertical graft diameters ranged from 7.0/6.0 to 8.0/7.0 mm, and 12 to 24 interrupted sutures were used. Simultaneously, 11 eyes (26.2%) underwent cataract surgery, 3 (7.1%) underwent intraocular lens (IOL) exchange, and 1 (2.4%) underwent secondary IOL implantation. The main outcome measures included intraoperative complications, immune reactions, and final astigmatism/visual acuity at the end of follow-up. RESULTS During surgery, 4 (9.5%) recipients had iris bleedings, and 10 (23.8%) ring-shaped superficial corneal thermal donor damages were detected. One (2.4%) immunologic graft rejection was seen in Fuchs dystrophy, and 3 (7.1%) in corneal ulcers occurred during follow-up (4.7 +/- 3.2 years). At the end of follow-up, corrected visual acuity (0.1/0.4; P < 0.001) and keratometric astigmatism (2.3 D/4.7 D, P = 0.001) increased significantly. CONCLUSIONS In EELPK, intraoperative disadvantages, such as the need for interrupted sutures and a tendency toward higher and more irregular astigmatism, may be expected. This study does not have the power to statistically confirm the tendency of EELPK toward a lower rate of immunologic graft rejections after normal-risk keratoplasty. However, EELPK may have advantages in deep or perforated elliptically shaped corneal ulcers (such as in acanthamoeba keratitis).
Collapse
Affiliation(s)
- Nóra Szentmáry
- Department of Ophthalmology, Friedrich Alexander University of Erlangen-Nürnberg, Erlangen, Germany.
| | | | | | | | | |
Collapse
|
3
|
Seitz B, Langenbucher A, Nguyen NX, Kus MM, Küchle M, Naumann GOH. [Results of the first 1,000 consecutive elective nonmechanical keratoplasties using the excimer laser. A prospective study over more than 12 years]. Ophthalmologe 2004; 101:478-88. [PMID: 15138797 DOI: 10.1007/s00347-003-0900-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND AND PURPOSE The purpose of this prospective clinical cross-sectional study was to analyse indications, intraoperative, perioperative and postoperative pecularities and complications as well as postoperative functional and morphologic results of the first 1000 consecutive elective round laser keratoplasties. PATIENTS AND METHODS The age of the 480 females and 520 males (362 x keratoconus), who had been operated on between 07/1989 and 04/2002 ranged from 20 to 92 years (mean 55+/-19). A total of 6 microsurgeons performed 718 x PK only, 222 x a triple procedure and 60 x additional IOL manoeuvres. Recipient and donor trephinations were accomplished with an 193 nm excimer laser (Carl Zeiss Meditec, Jena, Germany) from the epithelial side. RESULTS In 895 eyes with perioperative corneal erosion, epithelial healing took not more than 3 days in half of cases. During a follow-up period of 1.9+/-1.5 years, in 35 eyes episodes of acute diffuse (8 irreversible) and in 12 eyes episodes of chronic focal (5 irreversible) endothelial immunologic graft reactions (4.7%) occurred between 6 weeks and 4.7 years after PK. Before/after suture removal, median values of astigmatism were 1.5 diopters (D)/2.5 D refractive, 3.0 D/3.3 D keratometric, and 4.0 D/4.2 D topographic. Best-corrected visual acuity was 0.50/0.60, respectively. CONCLUSIONS More than 12 years of experience with this new technique indicate that besides optical advantages, nonmechanical trephination does not cause intraoperative or postoperative disadvantages for the patient. Under standardised surgical conditions a massive increase of astigmatism after suture removal seems to be avoidable with laser trephination in most cases due to reduction of decentration,"vertical tilt" and especially "horizontal torsion".
Collapse
Affiliation(s)
- B Seitz
- Augenklinik mit Poliklinik der Universität Erlangen-Nürnberg, Erlangen.
| | | | | | | | | | | |
Collapse
|
4
|
Abstract
The purposes of this study were to assess the expression patterns of heat shock proteins (Hsps), after eyeball heating or cooling, and to elucidate their relationships with corneal wound healing and intraocular complications after excimer laser treatment. Experimental mice were grouped into three according to local pretreatment type: heating, cooling, and control groups. The preconditioning was to apply saline eyedrops onto the cornea prior to photoablation. Following photoablation, we evaluated corneal wound healing, corneal opacity and lens opacity. Hsp expression patterns were elucidated with Western blot and immunohistochemical staining. The heating and cooling groups recovered more rapidly, and showed less corneal and lens opacity than the control group. In the heating and cooling groups, there were more expressions of Hsps in the cornea and lens than in the control group. These results were confirmed in the Hsp 70.1 knockout mouse model. Our study showed that Hsps were induced by the heating or cooling preconditioning, and appeared to be a major factor in protecting the cornea against serious thermal damage. Induced Hsps also seemed to play an important role in rapid wound healing, and decreased corneal and lens opacity after excimer laser ablation.
Collapse
Affiliation(s)
- Joon Mo Kim
- Department of Ophthalmology, College of Medicine, Seoul National University, Seoul, Korea
| | - Jae Chan Kim
- Department of Ophthalmology, Chung-Ang University Hospital, Seoul, Korea
| | - Woo Chan Park
- Department of Ophthalmology, Dong-A University Hospital, Busan, Korea
| | - Jeong-Sun Seo
- Ilchun Molecular Medicine Institute and Department of Biochemistry, College of Medicine, Seoul National University, Seoul, Korea
| | - Hae Ran Chang
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University, Seoul, Korea
| |
Collapse
|
5
|
Stojkovic M, Seitz B, Langenbucher A, Viestenz A, Viestenz A, Hofmann-Rummelt C, Schlötzer-Schrehardt U, Küchle M, Naumann GOH. Q-Switched Erbium:YAG Laser Corneal Trephination. Cornea 2004; 23:50-60. [PMID: 14701958 DOI: 10.1097/00003226-200401000-00009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess stromal thermal damage and cut regularity induced by nonmechanical Q-switched Er:YAG laser corneal trephination for penetrating keratoplasty. METHODS Corneal trephination was performed in 80 enucleated porcine eyes by Q-switched (2.94-microm) Er:YAG laser, along with donor and recipient masks made of metal or ceramic. All combinations of 0.65- or 0.96-mm spot diameter and 45- or 50-mJ/pulse energy setting were used with each of the masks at a 5-Hz repetition rate. Corneas were processed for histologic examinations. Stromal thermal damage was quantified on PAS-stained slides, and cut regularity was assessed semiquantitatively on a scale from 0 (regular) to 3 (highly irregular). Transmission electron microscopy and scanning electron microscopy were performed on selected specimens. RESULTS The least thermal damage (mean +/- SD = 6.2 +/- 0.7 microm) was found in the donor ceramic group with 50-mJ/pulse energy and 0.65-mm spot diameter, while the best regularity of the cut (1.2 +/- 0.4) was found in the donor ceramic group with 45-mJ pulse energy and 0.65-mm spot diameter. Thermal damage was less pronounced in donor than in recipient corneas (P < 0.01). Smaller spot diameter (0.65 mm) led to less thermal damage (P < 0.01) than the use of a 0.96-mm spot diameter. The differences in thermal damage between ceramic and metal masks were minimal. CONCLUSIONS After Q-switched Er:YAG laser corneal trephination for nonmechanical penetrating keratoplasty, reproducible high cut regularity and low concomitant thermal damage were observed. This is an encouraging finding in the search for a nonmechanical trephine for penetrating keratoplasty combining high precision and low cost.
Collapse
Affiliation(s)
- M Stojkovic
- Department of Ophthalmology, Friedrich Alexander University University of Erlangen-Nurnberg, Schwabachanlage 6, D-91054 Erlangen, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
De Souza RF, Seitz B, Langenbucher A, Hofmann-Rummelt C, Schlötzer-Schrehardt U, Viestenz A, Küchle M, Naumann GOH. Q-Switched 2.94-microm Er:YAG laser trephination with convergent and divergent cut angles for penetrating keratoplasty. Cornea 2003; 22:562-8. [PMID: 12883352 DOI: 10.1097/00003226-200308000-00015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To study the morphologic properties of perpendicular (P), convergent (C), and divergent (D) cut angles using different speeds of rotations during donor and recipient nonmechanical trephination for experimental penetrating keratoplasty. METHODS With a Q-switched 2.94-microm Er:YAG laser corneal trephination was performed in 150 enucleated porcine eyes using ceramic open masks with 8 "orientation teeth/notches" and an automated globe rotation device allowing different cut angles [0 degree (P), 10 and 20 degrees (C and D)] toward the optical axis and variation of the rotation speed [3, 7, and 11 rotations per minute (rpm)]. The regularity of the cut (I, regular; II, slightly irregular; III, irregular) was assessed by light microscopy. The area of thermal damage and the number and size of "spikes" in the stroma at the superficial, intermediate and deep level of the excision were analyzed using digital images and the Optimas image processing software. RESULTS The regularity of the cut was classified as I in 42%/22% of donor/recipient and as II in 41%/56%, respectively. The thermal damage was least expressed with D20 degree cut angle and donor mask (P < 0.01). With all cut angles and speeds of rotation, thermal damage at the deep level of excision was significantly smaller (P < 0.01). With different speeds of donor rotations, the thermal damage showed no significant difference. With recipient trephination, the thermal damage at the deep level was greatest with 7 rpm (P < 0.01). The number and size of spikes of thermal damage with donor and recipient masks were significantly smaller in the deep stroma (P < 0.01). CONCLUSIONS Q-switched Er:YAG laser trephination with appropriate settings results in low thermal damage zones at the cut margin. Different cut angles and speeds of trephination may affect the cut performance and quality of the excision. In our study, low rotation speed and divergent donor cut angles showed the best results. The cut quality and the small thermal damage with the Q-switched 2.94-microm Er:YAG laser seem to be tolerable for corneal trephination. Therefore, this modality may be a low-cost, easy-to-handle alternative for nonmechanical corneal transplantation in humans.
Collapse
|
7
|
Viestenz A, Küchle M, Seitz B, Langenbucher A, Viestenz A, Ferreira de Souza R, Naumann GOH. Superficial corneal effects of experimental nonmechanical penetrating keratoplasty using a Q-switched Er:YAG laser. Cornea 2002; 21:501-4. [PMID: 12072726 DOI: 10.1097/00003226-200207000-00012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess thermal effects of Q-switched Er:YAG laser trephination to corneal epithelium and superficial stroma using different mask types and materials for experimental penetrating keratoplasty. METHODS Laser trephination was performed in 20 freshly-enucleated porcine eyes (repetition rate 5 Hz, pulse energy 65 mJ, spot size 0.7 mm). We used flat, open-metal and ceramic masks for donor and recipient trephination placed directly onto the corneal surface. Main outcome measures as assessed by light microscopy after PAS staining of 8-microm paraffin sections included: extension of tissue thermal damage at the cut edge in the superficial and basal epithelial layers, the basement membrane and subepithelial stroma, and depth and width of epithelial/stromal involvement in the area of the donor mask contact. RESULTS The thermal damage in the superficial epithelium was more pronounced in donor (mean extension 61.6 +/- 15.6 microm) than in recipient (29.4 +/- 24.9 microm, p= 0.05) trephination. In donor trephination, thermal damage zone of the superficial epithelial layer was significantly smaller with ceramic than with metal masks (21.0 +/- 23.0 versus 61.6 +/- 15.6 microm, p= 0.014). In contrast, differences at basal epithelial layer (p= 0.44), basement membrane (p= 0.79), and subepithelial stroma (p= 0.2) were not statistically significant. Superficial donor involvement of the cornea adjacent to the paracentral donor mask contact zone was seen neither with ceramic nor with metal masks. CONCLUSION Superficial corneal alterations adjacent to the mask-cornea contact zone may be minimized by using the Er:YAG laser in a Q-switched mode. Ceramic masks, in contrast to metal masks, further reduce superficial thermal alterations at the cut edge.
Collapse
Affiliation(s)
- Anja Viestenz
- Department of Ophthalmology, University of Erlangen-Nürnberg, Schwabachenlage 6, D-91054 Erlangen, Germany.
| | | | | | | | | | | | | |
Collapse
|
8
|
Abstract
PURPOSE Photorefractive keratectomy (PRK) is still a widely used method for the correction of refractive error despite the advent of laser in situ keratomileusis (LASIK). However, both procedures are associated with significant side effects such as corneal haze and regression. Several factors have been implicated in the etiology of haze, one of which is thermal loading of the cornea. The purpose of this study was to investigate the temperature changes occurring during PRK when performed at different ablation depths. METHODS Noncontact, color-coded ocular thermography was performed with an infrared detector apparatus during PRK ablation on 19 ovine corneas. Five different refractive corrections were carried out ranging from -2.00 diopters (D) (ablation depth, 31.2 microm) to -10.00 D (ablation depth, 137.9 microm). RESULTS A temperature rise at the corneal surface was demonstrated in all 19 corneas. The mean rise in temperature was 7.35 +/- 1.13 degrees C with a maximum rise in temperature of 8.97 degrees C. A positive correlation was found between the refractive correction and the peak rise in temperature (r2 = 0.57, p< 0.0001). The rate of temperature change was greater for smaller treatments than for larger treatments (r2 = 0.79, p < 0.0001). Corneas undergoing larger treatments were subject to greater rises in temperature for longer periods of time. CONCLUSIONS This study suggests that the cornea undergoes a significant rise in temperature as a result of the PRK process. Further investigation is required to determine what effect this thermal loading has on the corneal wound healing response after PRK.
Collapse
Affiliation(s)
- C Maldonado-Codina
- Eurolens Research, Department of Optometry and Neuroscience, Manchester, United Kingdom.
| | | | | |
Collapse
|
9
|
Vetrugno M, Maino A, Valenzano E, Cardia L. Corneal Temperature Changes During Photorefractive Keratectomy Using the Laserscan 2000 Flying Spot Laser. J Refract Surg 2001; 17:454-9. [PMID: 11472003 DOI: 10.3928/1081-597x-20010701-07] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the thermal variations during photorefractive keratectomy (PRK) induced by a Laserscan 2000 flying spot excimer laser. METHODS Thermal changes during PRK were recorded using a non-contact infrared thermometer on 58 eyes with an attempted correction ranging from -1.25 to -9.00 D. The eyes were randomly divided into two groups to test the thermal effects of two different ablation scan techniques: sequential and randomized modes. Thermal measurements were also performed during myopic ablations on polymethylmethacrylate (PMMA) test plates. RESULTS On PMMA plates, a significant relationship between the amount of attempted myopic correction and thermal changes was established (P=.017 in sequential mode and P=.007 in randomized mode); this was not established for human eyes. With the sequential mode, an unexpected cooling effect after PRK was reported for each myopia subgroup (P=.003 in the low and high myopia subgroups, P<.001 in the medium myopia subgroup). With the randomized mode, the cooling effect was detected only for low amounts of myopia. CONCLUSION Despite a high repetition rate, the Laserscan 2000 flying spot laser minimized thermal shock. In comparison with randomized (nonsequential) pulse application, sequential pulsing showed no increase in the thermal loading of corneas. In fact, a cooling effect during PRK was produced.
Collapse
Affiliation(s)
- M Vetrugno
- Eye Institute, Department of Ophthalmology, University of Bari, Italy.
| | | | | | | |
Collapse
|
10
|
Behrens A, Seitz B, Küchle M, Langenbucher A, Kus MM, Rummelt C, Naumann GO. "Orientation teeth" in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 microm Er:YAG v 193 nm ArF excimer laser. Br J Ophthalmol 1999; 83:1008-12. [PMID: 10460766 PMCID: PMC1723204 DOI: 10.1136/bjo.83.9.1008] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND/AIMS "Orientation teeth" at the donor trephination margin and correspondent "notches" at the host margin facilitate graft orientation and avoid "horizontal torsion" induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. METHODS The procedure was performed in 20 enucleated pigs' eyes using open metal masks with eight "orientation teeth/notches" (0.3 x 0.15 mm, base x height), an automated globe rotation device, and either a 193 nm ArF excimer laser or a Q switched 2.94 microm Er:YAG laser. "Teeth/notches" were analysed by planimetry and scanning electron microscopy (SEM). RESULTS Mean size was 0.30 (0.027) x 0. 16 (0.017) mm for "teeth" and 0.30 (0.035) x 0.15 (0.021) mm for "notches" (excimer), and 0.31 (0.022) x 0.16 (0.015) mm and 0.30 (0.031) x 0.14 (0.021) mm respectively (Er:YAG). Overall, variability of notches was higher than that of teeth. By SEM, comparable cut regularity and sustained ablation profile were observed with both lasers. However, the corneal surface at the cut edge appeared slightly elevated (</=35 microm) in the Er:YAG group. CONCLUSION Orientation teeth/notches resembling those obtained with the excimer laser can be created using the Q switched Er:YAG laser, with potential advantages of lower costs, convenient equipment size, and solid state safety.
Collapse
Affiliation(s)
- A Behrens
- Department of Ophthalmology, University of Erlangen-Nürnberg, Erlangen, Germany
| | | | | | | | | | | | | |
Collapse
|
11
|
Seitz B, Langenbucher A, Kus MM, Küchle M, Naumann GO. Nonmechanical corneal trephination with the excimer laser improves outcome after penetrating keratoplasty. Ophthalmology 1999; 106:1156-64; discussion 1165. [PMID: 10366086 DOI: 10.1016/s0161-6420(99)90265-8] [Citation(s) in RCA: 141] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE To assess the impact of nonmechanical trephination on the outcome after penetrating keratoplasty (PK). DESIGN Prospective, randomized, cross-sectional, clinical, single-center study. PATIENTS A total of 179 eyes of 76 females and 103 males, mean age at the time of surgery 50.6 +/- 18.5 (range, 15-83) years. Inclusion criteria were (1) time interval from October 1992 to December 1997; (2) one surgeon (GOHN); (3) primary central PK; (4) Fuchs dystrophy (diameter, 7.5 mm) or keratoconus (diameter, 8.0 mm); (5) graft oversize, 0.1 mm; (6) no previous intraocular surgery; and (7) 16-bite double-running diagonal suture. INTERVENTION In a randomized fashion, eyes were assigned either to trephination with the 193-nm Meditec excimer laser (manually guided beam in patients, automated rotation device of artificial anterior chamber in donors) along metal masks with eight orientation teeth/notches (EXCIMER: 53 keratoconus, 35 Fuchs dystrophy; mean follow-up, 37 +/- 16 months) or with a hand-held motor trephine (Microkeratron; Geuder) ( CONTROL 53 keratoconus, 38 Fuchs dystrophy; mean follow-up, 38 +/- 14 months). Subjective refractometry (trial glasses), standard keratometry (Zeiss), and corneal topography analysis (TMS-1; Tomey) were performed before surgery, before removal of the first suture (15.2 +/- 4.2 months), and after removal of the second suture (21.4 +/- 5.6 months). MAIN OUTCOME MEASURES Keratometric and topographic net astigmatism as well as refractive cylinder; keratometric and topographic central power; best-corrected visual acuity (VA); surface regularity index (SRI), surface asymmetry index (SAI), and potential visual acuity (PVA) of the TMS-1. RESULTS Before suture removal, mean refractive/keratometric/topographic astigmatism did not differ significantly between EXCIMER (2.5 +/- 1.8 diopters [D]/3.4 +/- 2.8 D/4.7 +/- 3.1 D) and CONTROL groups (3.0 +/- 1.8 D/3.7 +/- 2.4 D/4.3 +/- 2.1 D). After suture removal, respective values were significantly lower in the EXCIMER group (2.8 +/- 2.0 D/3.0 +/- 2.1 D/3.8 +/- 2.6 D) than in the CONTROL group (4.2 +/- 2.4 D/6.1 +/- 2.7 D/6.7 +/- 3.1 D) (P < 0.0009). In the EXCIMER versus CONTROL group, mean VA increased from 20/100 versus 20/111 (P > 0.05) before surgery, to 20/31 versus 20/38 before (P = 0.001) and to 20/28 versus 20/39 (P < 0.00001) after suture removal. Mean spherical equivalent was significantly less myopic in the EXCIMER group before (-0.9 +/- 3.6 D vs. -2.6 +/- 3.4 D) (P = 0.01) and after suture removal (-1.4 +/- 3.1 D vs. -2.4 +/- 3.5 D) (P = 0.02). Mean SRI (P = 0.04) and PVA (P = 0.007) were significantly more favorable in the EXCIMER versus CONTROL group after suture removal (0.91 +/- 0.45 and 0.82 +/- 0.15 vs. 1.05 +/- 0.46 and 0.73 +/- 0.18). CONCLUSIONS Postkeratoplasty results seem to be superior using nonmechanical excimer laser trephination. Thus, this methodology is recommended as the procedure of first choice in avascular corneal pathologies requiring PK.
Collapse
Affiliation(s)
- B Seitz
- Department of Ophthalmology, University of Erlangen-Nürnberg, Erlangen, Germany.
| | | | | | | | | |
Collapse
|
12
|
|
13
|
Laser literature watch. JOURNAL OF CLINICAL LASER MEDICINE & SURGERY 1998; 15:95-8. [PMID: 9612185 DOI: 10.1089/clm.1997.15.95] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
14
|
Küchle M, Nguyen NX, Seitz B, Langenbucher A, Naumann GO. Blood-aqueous barrier after mechanical or nonmechanical excimer laser trephination in penetrating keratoplasty. Am J Ophthalmol 1998; 125:177-81. [PMID: 9467443 DOI: 10.1016/s0002-9394(99)80088-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE To analyze whether nonmechanical trephination with an excimer laser influences post-operative blood-aqueous barrier breakdown after penetrating keratoplasty. METHODS Patients undergoing penetrating keratoplasty for keratoconus or Fuchs dystrophy were prospectively randomly assigned to trephination by either excimer laser or conventional mechanical handheld motorized trephine. All surgery was performed by one surgeon, and preoperative, intraoperative, and postoperative treatment was identical in both groups. Aqueous flare was quantitatively determined postoperatively in a masked fashion by laser flare-cell meter. For statistical analysis, the nonparametric Wilcoxon-Mann-Whitney test was used. RESULTS A total of 52 eyes of 52 patients were examined (Fuchs dystrophy, 10; keratoconus, 42). During the early postoperative period (days 3 to 9), eyes that had undergone nonmechanical excimer laser trephination (25/52) showed significantly (P < .005) lower flare values than did eyes that had undergone mechanical trephination (27/ 52). In both groups, flare values returned to normal levels by 6 weeks postoperatively. CONCLUSION Early postoperative blood-aqueous barrier breakdown is less pronounced after penetrating keratoplasty with nonmechanical excimer laser trephination.
Collapse
Affiliation(s)
- M Küchle
- Department of Ophthalmology, University Erlangen-Nürnberg, Germany.
| | | | | | | | | |
Collapse
|
15
|
Seitz B, Langenbucher A, Fischer S, Kus MM, Vilchis E, Naumann GOH. The Regularity of Laser Keratectomy Depth in Nonmechanical Trephination for Penetrating Keratoplasty. Ophthalmic Surg Lasers Imaging Retina 1998. [DOI: 10.3928/1542-8877-19980101-07] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|