Shah DD, Carter P, Shivdasani MN, Fong N, Duan W, Esrafilzadeh D, Poole-Warren LA, Aregueta Robles UA. Deciphering platinum dissolution in neural stimulation electrodes: Electrochemistry or biology? Biomaterials 2024; 309:122575. [PMID: 38677220 DOI: 10.1016/j.biomaterials.2024.122575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/28/2024] [Accepted: 04/13/2024] [Indexed: 04/29/2024]
Abstract
Platinum (Pt) is the metal of choice for electrodes in implantable neural prostheses like the cochlear implants, deep brain stimulating devices, and brain-computer interfacing technologies. However, it is well known since the 1970s that Pt dissolution occurs with electrical stimulation. More recent clinical and in vivo studies have shown signs of corrosion in explanted electrode arrays and the presence of Pt-containing particulates in tissue samples. The process of degradation and release of metallic ions and particles can significantly impact on device performance. Moreover, the effects of Pt dissolution products on tissue health and function are still largely unknown. This is due to the highly complex chemistry underlying the dissolution process and the difficulty in decoupling electrical and chemical effects on biological responses. Understanding the mechanisms and effects of Pt dissolution proves challenging as the dissolution process can be influenced by electrical, chemical, physical, and biological factors, all of them highly variable between experimental settings. By evaluating comprehensive findings on Pt dissolution mechanisms reported in the fuel cell field, this review presents a critical analysis of the possible mechanisms that drive Pt dissolution in neural stimulation in vitro and in vivo. Stimulation parameters, such as aggregate charge, charge density, and electrochemical potential can all impact the levels of dissolved Pt. However, chemical factors such as electrolyte types, dissolved gases, and pH can all influence dissolution, confounding the findings of in vitro studies with multiple variables. Biological factors, such as proteins, have been documented to exhibit a mitigating effect on the dissolution process. Other biological factors like cells and fibro-proliferative responses, such as fibrosis and gliosis, impact on electrode properties and are suspected to impact on Pt dissolution. However, the relationship between electrical properties of stimulating electrodes and Pt dissolution remains contentious. Host responses to Pt degradation products are also controversial due to the unknown chemistry of Pt compounds formed and the lack of understanding of Pt distribution in clinical scenarios. The cytotoxicity of Pt produced via electrical stimulation appears similar to Pt-based compounds, including hexachloroplatinates and chemotherapeutic agents like cisplatin. While the levels of Pt produced under clinical and acute stimulation regimes were typically an order of magnitude lower than toxic concentrations observed in vitro, further research is needed to accurately assess the mass balance and type of Pt produced during long-term stimulation and its impact on tissue response. Finally, approaches to mitigating the dissolution process are reviewed. A wide variety of approaches, including stimulation strategies, coating electrode materials, and surface modification techniques to avoid excess charge during stimulation and minimise tissue response, may ultimately support long-term and safe operation of neural stimulating devices.
Collapse
Affiliation(s)
- Dhyey Devashish Shah
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | - Paul Carter
- Cochlear Ltd, Macquarie University, NSW, Australia
| | | | - Nicole Fong
- Cochlear Ltd, Macquarie University, NSW, Australia
| | - Wenlu Duan
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | - Dorna Esrafilzadeh
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | - Laura Anne Poole-Warren
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia; The Tyree Foundation Institute of Health Engineering, University of New South Wales, Sydney, Australia.
| | | |
Collapse
|
2
|
Orlemann C, Boehler C, Kooijmans RN, Li B, Asplund M, Roelfsema PR. Flexible Polymer Electrodes for Stable Prosthetic Visual Perception in Mice. Adv Healthc Mater 2024; 13:e2304169. [PMID: 38324245 DOI: 10.1002/adhm.202304169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 02/01/2024] [Indexed: 02/08/2024]
Abstract
Brain interfaces that can stimulate neurons, cause minimal damage, and work for a long time will be central for future neuroprosthetics. Here, the long-term performance of highly flexible, thin polyimide shanks with several small (<15 µm) electrodes during electrical microstimulation of the visual cortex, is reported. The electrodes exhibit a remarkable stability when several billions of electrical pulses are applied in vitro. When the devices are implanted in the primary visual cortex (area V1) of mice and the animals are trained to detect electrical microstimulation, it is found that the perceptual thresholds are 2-20 microamperes (µA), which is far below the maximal currents that the electrodes can withstand. The long-term functionality of the devices in vivo is excellent, with stable performance for up to more than a year and little damage to the brain tissue. These results demonstrate the potential of thin floating electrodes for the long-term restoration of lost sensory functions.
Collapse
Affiliation(s)
- Corinne Orlemann
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, 1105 BA, The Netherlands
| | - Christian Boehler
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany
| | - Roxana N Kooijmans
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, 1105 BA, The Netherlands
- Institute for Neuroscience and Medicine (INM-1), Forschungszentrum Jülich, 52428, Jülich, Germany
| | - Bingshuo Li
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, 1105 BA, The Netherlands
| | - Maria Asplund
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany
- Department of Microtechnology and Nanoscience, Chalmers University of Technology, Gothenburg, 412 96, Sweden
| | - Pieter R Roelfsema
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Royal Netherlands Academy of Arts and Sciences, Amsterdam, 1105 BA, The Netherlands
- Laboratory of Visual Brain Therapy, Sorbonne Université, Institut National de la Santé et de la Recherche Médicale, Centre National de la Recherche Scientifique, Institut de la Vision, Paris, F-75012, France
- Department of Integrative Neurophysiology, Centre for Neurogenomics and Cognitive Research, VU University, Amsterdam, 1081 HV, The Netherlands
- Department of Neurosurgery, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, 1105 AZ, The Netherlands
| |
Collapse
|
3
|
Harris AR. Limitations in the electrochemical analysis of voltage transients. J Neural Eng 2024; 21:013003. [PMID: 38215494 DOI: 10.1088/1741-2552/ad1e23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 01/12/2024] [Indexed: 01/14/2024]
Abstract
Objective. Chronopotentiometric voltage transients (VTs) are used to assess the performance of bionic electrodes. The data obtained from VTs are used to define the safe operating conditions of clinical devices. Various approaches to analysing VTs have been reported, and a number of limitations in the accuracy of the measurements in relation to electrode size have been noted previously.Approach. The impact of electronic hardware and electrode configuration on VTs is discussed.Main results. The slew rate, rise time, sample time, minimum pulse length and waveform averaging characteristics of the electronic hardware, and electrode configuration will impact on VT measurement accuracy. Subsequently, activation and polarisation voltage measurements, and the definition of safe stimulation levels can be affected by the electronic hardware and electrode configuration.Significance. This article has identified some limitations in the previous literature related to the measurement and reporting of VTs and subsequent analysis of access and polarisation voltages. Furthermore, the commonly used Shannon plot used to define safe stimulation protocols does not correct for uncompensated resistance, account for electrode roughness or changes in electrode configuration. The creation of a safe stimulation plot which has been corrected for uncompensated resistance would generate more widely applicable stimulation guidelines for clinical devices used in different anatomical locations such as endovascular neural interfaces.
Collapse
Affiliation(s)
- Alexander R Harris
- Department of Biomedical Engineering, University of Melbourne, Melbourne 3010, Australia
| |
Collapse
|
4
|
Matter L, Harland B, Raos B, Svirskis D, Asplund M. Generation of direct current electrical fields as regenerative therapy for spinal cord injury: A review. APL Bioeng 2023; 7:031505. [PMID: 37736015 PMCID: PMC10511262 DOI: 10.1063/5.0152669] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 08/21/2023] [Indexed: 09/23/2023] Open
Abstract
Electrical stimulation (ES) shows promise as a therapy to promote recovery and regeneration after spinal cord injury. ES therapy establishes beneficial electric fields (EFs) and has been investigated in numerous studies, which date back nearly a century. In this review, we discuss the various engineering approaches available to generate regenerative EFs through direct current electrical stimulation and very low frequency electrical stimulation. We highlight the electrode-tissue interface, which is important for the appropriate choice of electrode material and stimulator circuitry. We discuss how to best estimate and control the generated field, which is an important measure for comparability of studies. Finally, we assess the methods used in these studies to measure functional recovery after the injury and treatment. This work reviews studies in the field of ES therapy with the goal of supporting decisions regarding best stimulation strategy and recovery assessment for future work.
Collapse
Affiliation(s)
- Lukas Matter
- Author to whom correspondence should be addressed:
| | - Bruce Harland
- School of Pharmacy, The University of Auckland, NZ 1023 Auckland, New Zealand
| | - Brad Raos
- School of Pharmacy, The University of Auckland, NZ 1023 Auckland, New Zealand
| | - Darren Svirskis
- School of Pharmacy, The University of Auckland, NZ 1023 Auckland, New Zealand
| | | |
Collapse
|
5
|
Shepherd RK, Carter PM, Enke YL, Thompson A, Flynn B, Trang EP, Dalrymple AN, Fallon JB. Chronic intracochlear electrical stimulation at high charge densities: reducing platinum dissolution. J Neural Eng 2020; 17:056009. [DOI: 10.1088/1741-2552/abb7a6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
6
|
Pfau J, Ganatra D, Weltin A, Urban G, Kieninger J, Stieglitz T. Electrochemical Stability of Thin-Film Platinum as Suitable Material for Neural Stimulation Electrodes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:3762-3765. [PMID: 31946693 DOI: 10.1109/embc.2019.8856621] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Only thin-film technology can satisfy the requirements of high spatial selectivity at high-channel-count electrode array designs by simultaneously good conformability to the targeted tissue through mechanical flexibility enriching future applications of functional neural stimulation. However, caused by the high impact of the microstructure on the mechanical and electrochemical film properties, varying fabrication processes of the same thin-film makes the difference between acute and chronic long-term stable electrodes. The influence of standard clinical electrical pulsing on flexible polyimide-based thin-film platinum electrodes for neuroprostheses, either sputter deposited or evaporated, and different diameters was assessed and compared. The electrochemical and morphological analysis showed a higher corrosion susceptibility and electrochemical degradation for the sputter deposited platinum electrodes with even total failures of smaller diameters. In contrast, the evaporated thin-films provided itself as more stable and reliable metallization with also smaller electrodes keeping their film integrity intact over the experimental period, -appearing to be the preferable material for improving thin-film electrodes' longevity.
Collapse
|
7
|
Harris AR, Newbold C, Carter P, Cowan R, Wallace GG. Using Chronopotentiometry to Better Characterize the Charge Injection Mechanisms of Platinum Electrodes Used in Bionic Devices. Front Neurosci 2019; 13:380. [PMID: 31118879 PMCID: PMC6508053 DOI: 10.3389/fnins.2019.00380] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 04/02/2019] [Indexed: 11/13/2022] Open
Abstract
The safe charge injection capacity and charge density of neural stimulating electrodes is based on empirical evidence obtained from stimulating feline cortices. Stimulation induced tissue damage may be caused by electrochemical or biological mechanisms. Separating these mechanisms requires greater understanding of charge transfer at the electrode-tissue interface. Clinical devices typically use a biphasic waveform with controlled current. Therefore, the charge injection mechanism and charge injection capacity of platinum was assessed on a commercial potentiostat by chronopotentiometry (controlled current stimulation). Platinum is a non-ideal electrode, charge injection by chronopotentiometry can be passed via capacitive and Faradaic mechanisms. Electrodes were tested under a variety of conditions to assess the impact on charge injection capacity. The change in electrode potential (charge injection capacity) was affected by applied charge density, pulse length, pulse polarity, electrode size, polishing method, electrolyte composition, and oxygen concentration. The safe charge injection capacity and charge density could be increased by changing the electrode-solution composition and stimulation parameters. However, certain conditions (e.g., acid polished electrodes) allowed the electrode to exceed the water electrolysis potential despite the stimulation protocol being deemed safe according to the Shannon plot. Multiple current pulses led to a shift or ratcheting in electrode potential due to changes in the electrode-solution composition. An accurate measure of safe charge injection capacity and charge density of an implantable electrode can only be obtained from suitable conditions (an appropriately degassed electrolyte and clinically relevant electrode structure). Cyclic voltammetric measurement of charge storage capacity can be performed on implantable electrodes, but will not provide information on electrode stability to multiple chronopotentiometric pulses. In contrast, chronopotentiometry will provide details on electrode stability, but the minimum time resolution of typical commercial potentiostats (ms range) is greater than used in a clinical stimulator (μs range) so that extrapolation to short stimulation pulses is required. Finally, an impedance test is typically used to assess clinical electrode performance. The impedance test is also based on a biphasic chronopotentiometic waveform where the measured potential is used to calculate an impedance value. Here it is shown that the measured potential is a function of many parameters (solution composition, electrode area, and surface composition). Subsequently, impedance test results allow electrode comparison and to indicate electrode failure, but use of Ohm's law to calculate an impedance value is not valid.
Collapse
Affiliation(s)
- Alexander R. Harris
- ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW, Australia
- The HEARing CRC, University of Melbourne, Melbourne, VIC, Australia
| | - Carrie Newbold
- The HEARing CRC, University of Melbourne, Melbourne, VIC, Australia
- Department of Audiology and Speech Pathology, University of Melbourne, Melbourne, VIC, Australia
| | - Paul Carter
- Cochlear, Ltd., Macquarie University, Sydney, NSW, Australia
| | - Robert Cowan
- The HEARing CRC, University of Melbourne, Melbourne, VIC, Australia
- Department of Audiology and Speech Pathology, University of Melbourne, Melbourne, VIC, Australia
| | - Gordon G. Wallace
- ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW, Australia
- The HEARing CRC, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
8
|
Shepherd RK, Carter PM, Enke YL, Wise AK, Fallon JB. Chronic intracochlear electrical stimulation at high charge densities results in platinum dissolution but not neural loss or functional changes in vivo. J Neural Eng 2018; 16:026009. [PMID: 30523828 DOI: 10.1088/1741-2552/aaf66b] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Although there are useful guidelines defining the boundary between damaging and non-damaging electrical stimulation they were derived from acute studies using large surface area electrodes in direct contact with cortical neurons. These parameters are a small subset of the parameters used by neural stimulators. More recently, histological examination of cochleae from patients that were long-term cochlear implant users have shown evidence of particulate platinum (Pt). The pathophysiological effect of Pt within the cochlea is unknown. We examined the response of the cochlea to stimulus levels beyond those regarded as safe, and to evaluate the pathophysiological response of the cochlea following chronic stimulation at charge densities designed to induce Pt corrosion in vivo. APPROACH 19 guinea pigs were systemically deafened and implanted with a cochlear electrode array containing eight Pt electrodes of 0.05, 0.075 or 0.2 mm2 area. Animals were electrically stimulated continuously for 28 d using charge balanced current pulses at charge densities of 400, 267 or 100 µC/cm2/phase. Electrically-evoked auditory brainstem responses (EABRs) were recorded to monitor neural function. On completion of stimulation electrodes were examined using scanning electron microscopy (SEM) and cochleae examined histology. Finally, analysis of Pt was measured using energy dispersive x-ray spectroscopy (EDS) and inductively coupled plasma mass spectrometry (ICP-MS). MAIN RESULTS Compared with unstimulated control electrodes and electrodes stimulated at 100 µC/cm2/phase, stimulation at 267 or 400 µC/cm2/phase resulted in significant Pt corrosion. Cochleae stimulated at these high charge densities contained particulate Pt. The extent of the foreign body response depended on the level of stimulation; cochleae stimulated at 267 or 400 µC/cm2/phase exhibited an extensive tissue response that included a focal region of necrosis close to the electrode. Despite chronic stimulation at high charge densities there was no loss of auditory neurons (ANs) in stimulated cochleae compared with their contralateral controls. Indeed, we report a statistically significant increase in AN density proximal to electrodes stimulated at 267 or 400 µC/cm2/phase. Finally, there was no evidence of a reduction in AN function associated with chronic stimulation at 100, 267 or 400 µC/cm2/phase as evidenced by stable EABR thresholds over the stimulation program. SIGNIFICANCE Chronic electrical stimulation of Pt electrodes at 267 or 400 µC/cm2/phase evoked a vigorous tissue response and produced Pt corrosion products that were located close to the electrode. Despite these changes at the electrode/tissue interface there was no evidence of neural loss or a reduction in neural function.
Collapse
Affiliation(s)
- Robert K Shepherd
- Bionics Institute, St Vincent's Hospital, Melbourne, Australia. Medical Bionics Department, The University of Melbourne, Melbourne, Australia
| | | | | | | | | |
Collapse
|
9
|
Mueller M, de la Oliva N, Del Valle J, Delgado-Martínez I, Navarro X, Stieglitz T. Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring. J Neural Eng 2018; 14:066016. [PMID: 28695839 DOI: 10.1088/1741-2552/aa7eea] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. APPROACH We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. MAIN RESULTS The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. SIGNIFICANCE Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.
Collapse
Affiliation(s)
- Matthias Mueller
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 102, D-79110 Freiburg, Germany
| | | | | | | | | | | |
Collapse
|
10
|
Leber M, Bhandari R, Mize J, Warren DJ, Shandhi MMH, Solzbacher F, Negi S. Long term performance of porous platinum coated neural electrodes. Biomed Microdevices 2017; 19:62. [DOI: 10.1007/s10544-017-0201-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
Green RA, Matteucci PB, Dodds CWD, Palmer J, Dueck WF, Hassarati RT, Byrnes-Preston PJ, Lovell NH, Suaning GJ. Laser patterning of platinum electrodes for safe neurostimulation. J Neural Eng 2014; 11:056017. [PMID: 25188649 DOI: 10.1088/1741-2560/11/5/056017] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Laser surface modification of platinum (Pt) electrodes was investigated for use in neuroprosthetics. Surface modification was applied to increase the surface area of the electrode and improve its ability to transfer charge within safe electrochemical stimulation limits. APPROACH Electrode arrays were laser micromachined to produce Pt electrodes with smooth surfaces, which were then modified with four laser patterning techniques to produce surface structures which were nanosecond patterned, square profile, triangular profile and roughened on the micron scale through structured laser interference patterning (SLIP). Improvements in charge transfer were shown through electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and biphasic stimulation at clinically relevant levels. A new method was investigated and validated which enabled the assessment of in vivo electrochemically safe charge injection limits. MAIN RESULTS All of the modified surfaces provided electrical advantage over the smooth Pt. The SLIP surface provided the greatest benefit both in vitro and in vivo, and this surface was the only type which had injection limits above the threshold for neural stimulation, at a level shown to produce a response in the feline visual cortex when using an electrode array implanted in the suprachoroidal space of the eye. This surface was found to be stable when stimulated with more than 150 million clinically relevant pulses in physiological saline. SIGNIFICANCE Critical to the assessment of implant devices is accurate determination of safe usage limits in an in vivo environment. Laser patterning, in particular SLIP, is a superior technique for improving the performance of implant electrodes without altering the interfacial electrode chemistry through coating. Future work will require chronic in vivo assessment of these electrode patterns.
Collapse
Affiliation(s)
- R A Green
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney 2052, Australia
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Boretius T, Jurzinsky T, Koehler C, Kerzenmacher S, Hillebrecht H, Stieglitz T. High-porous platinum electrodes for functional electrical stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:5404-7. [PMID: 22255559 DOI: 10.1109/iembs.2011.6091336] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper reports on the preparation and characterization of highly porous platinum electrodes for functional electrical stimulation. Thin-film platinum electrodes were roughened by electrochemical deposition of platinum-copper alloys and subsequent removal of copper using cyclic voltammetry (CV). Prepared samples were characterized by electrochemical impedance spectroscopies (EIS), CVs and long-term pulse testing. The electrodes exhibited an increased porosity by a factor of ~238 when compared to sputtered platinum electrodes. EIS measurements showed a decreased impedance of about 85% and pulse tests suggested a stable coating over at least 250 million pulses.
Collapse
Affiliation(s)
- Tim Boretius
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany.
| | | | | | | | | | | |
Collapse
|
13
|
|
14
|
Vuckovic A, Tosato M, Struijk JJ. A comparative study of three techniques for diameter selective fiber activation in the vagal nerve: anodal block, depolarizing prepulses and slowly rising pulses. J Neural Eng 2008; 5:275-86. [DOI: 10.1088/1741-2560/5/3/002] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Behrend MR, Ahuja AK, Weiland JD. Dynamic current density of the disk electrode double-layer. IEEE Trans Biomed Eng 2008; 55:1056-62. [PMID: 18334397 DOI: 10.1109/tbme.2008.915723] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
With applied potential, the current distribution at the surface of a disk electrode is spatially nonuniform and time dependent. This distribution is important to control in applications that desire a uniform current density profile or minimal corrosion. We examine the current density profile of a capacitive disk electrode subjected to a voltage-step using finite element analysis software to solve the system of partial differential equations. In detailed analyses we show quantitatively that the current density shifts from peripheral enhancement to near-uniformity following 1/2 of the lumped element time constant. As charging continues, the current density is slightly enhanced in the central region. We present curves for the evolution of local "time constants" as time progresses and calculate their effective values. The model is intended to be the basis of future work to control the corrosion profile of biologically implantable electrodes of arbitrary shape. Data suggest a means to control corrosion by retarding the edges of a stimulus pulse. Additionally, smaller electrodes may be more effective in fully utilizing surface area for charge transfer due to their shorter time constants.
Collapse
Affiliation(s)
- Matthew R Behrend
- Department of Electrical Engineering, University of Southern California, Los Angeles, CA 90033, USA.
| | | | | |
Collapse
|
16
|
Donaldson PE, Donaldson NDN, Rushton DN, Perkins TA. Technical note. Estimated electrode operating conditions of the first London Mk V implanted stimulator. J Med Eng Technol 1998; 22:216-9. [PMID: 9807744 DOI: 10.3109/03091909809032545] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The electrodes of an implanted stimulator must be operated in such a way that the task of converting an electron current in metal to an ion current in tissue is achieved without release of noxious chemical species into the tissue, and without significant corrosion of the electrode metal. Both these effects depend on the charge density at which the electrodes are operated. In bringing a newly designed multichannel stimulator into service, the charge densities can only be known when the operating stimulus strengths have been determined. Even then, unless the stimulator is arranged to telemeter out what it is doing, any charge-density figures obtained have the character of estimates, rather than measurements. The first London Mk. V stimulator is used to enable a paraplegic woman to stand up. This note provides estimates of the average charge density and corrosion rate for the Pt--Ir electrodes used. These fall within limits which we believe to be generally accepted as safe.
Collapse
Affiliation(s)
- P E Donaldson
- Department of Medical Physics and Bioengineering, Shropshire House, London, UK
| | | | | | | |
Collapse
|
17
|
Nene AV, Jennings SJ. Hybrid paraplegic locomotion with the ParaWalker using intramuscular stimulation: a single subject study. PARAPLEGIA 1989; 27:125-32. [PMID: 2785668 DOI: 10.1038/sc.1989.19] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Functional intramuscular electrical stimulation of the gluteus maximus and gluteus medius on the stance side whilst walking is reported. The subject was an adult, male, post-traumatic complete paraplegic with lesion level at T7. He had been using surface stimulation to aid his walking with the adult ParaWalker Orthosis but suffered unpleasant anterior abdominal wall muscle contractions with high amplitude stimulation. The experimental use of percutaneous intramuscular Platinum/Iridium wire electrodes demonstrated that more forceful contractions of the buttock muscles could be achieved without any effect on abdominal wall musculature. This prompted the use of a permanent, implanted system. The system is inductively coupled to an external control device and is working satisfactorily 7 months after implantation.
Collapse
Affiliation(s)
- A V Nene
- Orthotic Research and Locomotor Assessment Unit, Robert Jones & Agnes Hunt Orthopaedic Hospital, Oswestry, Shropshire, UK
| | | |
Collapse
|
18
|
Ison KT, Walliker JR. Platinum and platinum/iridium electrode properties when used for extracochlear electrical stimulation of the totally deaf. Med Biol Eng Comput 1987; 25:403-13. [PMID: 3450991 DOI: 10.1007/bf02443361] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
19
|
|
20
|
Craggs MD, Donaldson NN, Donaldson PE. Performance of platinum stimulating electrodes, mapped on the limit-voltage plane. Part 1. Charge injection in vivo. Med Biol Eng Comput 1986; 24:424-30. [PMID: 3491938 DOI: 10.1007/bf02442699] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|